MIB Viewer

cbrDS1E1NewVcConfSignalingType

OBJECT-TYPE
1.3.6.1.4.1.2011.2.1.1.1.1.15.6.1.1.6
Access
read-write
Status
mandatory
Sub-identifiers
0
This object indicates the associated signaling application type. This object defaults to no_signaling in unstructured/structured data modes and cannot be modified in these modes. This object can only be set in structured voice mode. All signaling application type values are applicable in this mode except for no-signaling. An error will result if an attempt is made to set no_signaling in structured voice mode. In addition, an error will result if an attempt is made to set e1-r2 to a T1 interface. The default value is no-signaling(1).
INTEGER { no-signaling(1), em-plar(2), fxo-loop-start(3), fxs-loop-start(4), fxo-ground-start(5), fxs-ground-start(6), e1-r2(7) }