cbrDS1E1PortConfSignaling

OBJECT-TYPE
1.3.6.1.4.1.2011.2.1.1.1.1.15.2.1.1.6
Access
read-write
Status
mandatory
Sub-identifiers
0
This object is applicable to E1 interfaces ONLY and indicates if signaling information is enabled or disabled. Signaling information is always disabled in E1 single-frame or unframed mode. Signaling information is always enabled in structured voice multi-frame mode. An error is returned if a set is applied to an inappropriate cardtype (eg. E1-CAS is applied to a T1 cardtype). In addition, the crc-4 configuration object is automatically disabled if the E1 interface is in unstructured multi-frame mode and signaling is disabled. NOTE: This object can ONLY be changed in E1 unstructured multi-frame mode. The default value is no-signaling (1).
INTEGER { no-signaling(1), e1-CAS(2) }