MIB Viewer

ADIC-SANMGR-PROXY-MIB

438 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.3764.1.1.400.10Nodesanmgr-proxy
1.3.6.1.4.1.3764.1.1.400.10.10Nodepathlight
1.3.6.1.4.1.3764.1.1.400.10.10.2Nodeagent
1.3.6.1.4.1.3764.1.1.400.10.10.2.1TableagentScalarTablenot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1RowagentScalarEntrynot-accessiblemandatoryA component entry containing objects for a particular component.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.1ColumnpaIdentifyread-writemandatoryFlash the READY light on the SAN Data Gateway front panel. A non-zero value turns the LED on for the specified number of seconds. Zero turns LED off.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.2ColumnpaRebootread-writemandatoryWriting a reboot(2) value here causes immediate reboot.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.3ColumnpaHealthCheckValueread-onlymandatoryValue in percent of health check tests passed.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.4ColumnpaHealthCheckLevelread-writemandatoryScrutiny level of health check function.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.5ColumnpaHealthCheckIntervalread-writemandatoryHealth Check interval in minutes.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.6ColumnpaEvRptLevelread-writemandatoryUsed when retrieving Event Log. Events with log level greater than paEvRptLevel are not retrieved.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.7ColumnpaEventLogLevelsread-writemandatoryEach of 255 event types has an 8-bit level used when reading log. Currently valid LogLevel range is 0-3.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.8ColumnpaTrapThresholdsread-writemandatoryEach of 255 event types has an 8-bit threshold. When the number of events exceeds the Trap Threshold, a trap is generated and sent to all parties listed in the…
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.9ColumnpaBaudRateread-writemandatorySerial baud rate for SAN Gateway Service Port. Currently, the Agent does not support baud rate change: the rate is hard-coded to 19200 baud.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.11ColumnpaLogSizeread-writemandatoryNumber of records in entire event log. (Not just current records since boot.)
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.12ColumnpaCommandread-writemandatoryUsed for issuing command to SNMP agent.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.13ColumnpaLogBootread-onlymandatoryAbsolute index of first log entry at boot.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.14ColumnpaLogNCurrentread-writemandatorySNMP Get (read) returns number of records since boot subject to viewing level filtering. SNMP Set (write) copies this number of records since boot (subject to …
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.15ColumnpaLogChronFirstread-writeobsoleteUsed to request range of records from paLogChronFirst to paLogChronLast
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.16ColumnpaLogChronLastread-writeobsoleteUsed to request range of records from paLogChronFirst to paLogChronLast
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.17ColumnpaLogScrollread-writeobsoleteUsed to request previous/next range of records event log
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.18ColumnpaLogFilenameread-writemandatoryUsed to save event log to a file.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.19ColumnpaEnvironmentStateread-onlymandatoryTemperature and Voltage Status of SAN Data Gateway: ********************************** (LSB) bit 0 Auxiliary Power bit 1 Main Power bit 2 Temperature Warning b…
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.20ColumnpaGatewayFWRevread-onlymandatorySAN Data Gateway Firmware Revision information.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.21ColumnpaGatewayHWRevread-onlymandatorySAN Data Gateway Hardware Revision information.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.22ColumnpaSnmpFWRevread-onlymandatorySNMP Agent Firmware Revision information.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.23ColumnpaRidTagread-onlymandatorySAN Data Gateway RIDTag.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.24ColumnpaSerialNumberread-onlymandatorySAN Data Gateway Serial Number.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.25ColumnpaServerVersionread-writemandatoryRemote Management software writes Server version information here to customize SNMP Agent behavior.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.26ColumnpaProductTyperead-onlymandatoryType of SAN device
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.27ColumnpaVPSEnabledread-onlymandatoryState of VPS Access Control enable.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.28ColumnpaLicenseKeyread-writemandatoryUsed to pass feature enabling license keys.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.29ColumnpaThirdPartyCopyEnabledread-onlymandatoryState of Extended 3rd Party Copy enable. Enabled means that a valid license key has been entered for this feature.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.30ColumnpaVPSStatusread-writemandatoryState of Virtual Private SAN feature. bit 0 : active or inactive. bit 1 : licensed or not licensed. Bit 1 is redundant with MIB var paVPSEnabled. Writing 1 to …
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.31ColumnpaThirdPartyCopyStatusread-writemandatoryState of Extended 3rd Party Copy feature. bit 0 : active or inactive. bit 1 : licensed or not licensed. Bit 1 is redundant with MIB var paThirdPartyCopyEnabled…
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.32ColumnpaCommandControlLUNread-writemandatoryGateway/Router Command and Control LUN
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.33ColumnpaSanDirectorEnabledread-onlymandatoryState of SAN Director Support for this device. To enable, user must write a valid license key to OID paLicenseKey or enter the license key from the service por…
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.34ColumnpaNodeNameread-onlymandatorySAN Gateway Node Name.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.35ColumnpaVPMStatusread-writemandatoryState of Virtual Private Map feature. bit 0 : active or inactive. bit 1 : licensed or not licensed.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.36ColumnpaSRSStatusread-writemandatoryState of SAN Replication Services feature. bit 0 : active or inactive. bit 1 : licensed or not licensed.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.37ColumnpaEthernetTyperead-onlymandatoryCurrent Ethernet Speed.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.38ColumnpaTrapSequenceNumberread-onlymandatorySequence number of last trap sent by this SNMP Agent.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.39ColumnpaSysNodeNameModeread-writemandatoryAlgorithm used when computing Fibre Channel World Wide Node Name for each port. If the value is sameForEachPort(0), then the World Wide Node Name is the same f…
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.40ColumnpaGhostIOTimeToLiveread-writemandatoryThe amount of time that commands can remain queued in the SNC before being considered stale and discarded. 0 : Never discard (ghost I/O disabled) 1 - 30 : TTL …
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.41ColumnpaMaxLunread-onlymandatoryThe maximum LUN value possible.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.42ColumnpaEVPSEnabledread-writemandatoryBit 0: EVPS active if 1, inactive if 0 Bit 1: EVPS licensed if 1, unlicensed if 0
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.43ColumnpaMaxHostLunread-onlymandatoryThe number of devices one host can see
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.44ColumnpaAMPStatusread-writemandatoryStatus of Automatic Multipath feature. bit 0 : active or inactive. bit 1 : licensed or not licensed.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.45ColumnpaEnableAllScsiTargetsread-writemandatoryUsed to Enable/Disable all-scsi-targets.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.46ColumnpaHPFStatusread-writemandatoryBit 0: HPF active if 1, inactive if 0 Bit 1: HPF licensed if 1, unlicensed if 0
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.47ColumnpaSoip2iRescanread-writemandatoryWriting true(1) here causes SOIP2 initiator to rescan its bus.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.48ColumnpaSoipiRescanread-writemandatoryWriting true(1) here causes SOIP initiator to rescan its bus.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.49ColumnpaFLBStatusread-writemandatoryStatus of Load Balancing feature. bit 0 : active or inactive. bit 1 : licensed or not licensed.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.50ColumnpaSoip2iScanPeriodread-writemandatorySOIP2 Initiator Scan period in seconds. 0 will disable scan.
1.3.6.1.4.1.3764.1.1.400.10.10.2.1.1.51ColumnpaCommandFlowLogEnabledread-onlymandatoryReturns TRUE iff Command Flow Logging is available. Returns FALSE otherwise.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500TablepaEventLognot-accessiblemandatoryEntry point for the Agent Event Log Table.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1RowpaEventLogEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.1ColumnpaIndexread-onlymandatoryMIB EventLogEntry Table index.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.2ColumnpaTimeread-onlymandatoryTime stamp (since boot).
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.3ColumnpaProducerread-onlymandatoryNumeric identifier for this event's producer.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.4ColumnpaEventClassread-onlymandatoryNumeric identifier for this event's class.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.5ColumnpaEventCoderead-onlymandatoryNumeric code for this event.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.6ColumnpaSeqread-onlymandatorySequence number (relative record number) since boot.
1.3.6.1.4.1.3764.1.1.400.10.10.2.500.1.7ColumnpaEventVarsread-onlymandatoryText description of event.
1.3.6.1.4.1.3764.1.1.400.10.10.3Nodedevices
1.3.6.1.4.1.3764.1.1.400.10.10.3.1TablepdDevicesnot-accessiblemandatoryPathlight Physical Device Group *********************************** Each device attached to the Gateway has an entry here.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1RowpdDevEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.1ColumnpdIndexread-onlymandatoryMIB table index
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.2ColumnpdUIDread-onlymandatoryUniversal Identifier
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.3ColumnpdTyperead-onlymandatoryDevice Type i.e. disk/tape/cd etc.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.4ColumnpdVendorread-onlymandatoryDevice Vendor
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.5ColumnpdProductread-onlymandatoryDevice Product Identifier
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.6ColumnpdBlockSizeread-onlymandatoryBlock size in Bytes
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.7ColumnpdCapacityread-onlymandatoryCapacity in BLOCKS (see pdBlockSize)
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.8ColumnpdAccessread-onlymandatory
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.9ColumnpdRemovableread-onlymandatoryIs device removable ?
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.10ColumnpdStatusread-onlymandatoryDevice Status
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.11ColumnpdSpeedread-onlymandatoryDevice Speed in MBytes/second
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.12ColumnpdWidthread-onlymandatoryData path width in bits
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.13ColumnpdSerialread-onlymandatoryDevice Serial Number
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.14ColumnpdIdentifyread-writemandatoryNumber of seconds to flash identifying LED. Write here to flash LED on device if supported by Gateway and device. Zero turns LED off.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.15ColumnpdInterfaceTyperead-onlymandatoryThis device's type of communication interface.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.16ColumnpdBusread-onlymandatorySCSI bus number
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.17ColumnpdIdread-onlymandatorySCSI Address ID
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.18ColumnpdLunread-onlymandatorySCSI Logical Unit Number.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.19ColumnpdCtlrIndexread-onlymandatoryIndex of this device's controller in the Controllers MIB table and type-specific controller tables
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.20ColumnpdHWRevread-onlymandatoryDevice hardware revision number/identifier
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.21ColumnpdFWRevread-onlymandatoryDevice firmware revision number/identifier
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.22ColumnpdResetread-writemandatoryGeneric device reset if supported. Write reset(1) here to reset device if supported by Gateway firmware and device.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.23ColumnpdStatusBitsread-onlymandatoryDevice status bits as per SCSI spec.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.24ColumnpdScsiAnsiLevelread-onlymandatoryDevice SCSI level.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.25ColumnpdTargetLunread-onlymandatoryThis target device's Logical Unit Number as seen from attached host.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.26ColumnpdIpAddressread-onlymandatoryThis target device's IP Address if applicable. In case of SAN Gateway or Router, this information is used to allow arbitrary drill-down capability.
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.27ColumnpdAltVendorread-onlymandatoryDevice alternate Vendor
1.3.6.1.4.1.3764.1.1.400.10.10.3.1.1.28ColumnpdAltProductread-onlymandatoryDevice alternate Product Identifier
1.3.6.1.4.1.3764.1.1.400.10.10.4Nodecontrollers
1.3.6.1.4.1.3764.1.1.400.10.10.4.1TablepcControllersnot-accessiblemandatoryPathlight Controller Group ******************************* All controllers installed in the SAN Data Gateway have an entry here AND a parallel entry in the con…
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1RowpcCtlrEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.1ColumnpcIndexread-onlymandatoryMIB Table index.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.2ColumnpcTyperead-onlymandatoryCommunication Interface type.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.3ColumnpcVendorIdread-onlymandatoryInteger vendor ID for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.4ColumnpcProductIdread-onlymandatoryVendor's integer ID for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.5ColumnpcRevisionread-onlydeprecatedRevision information for this controller. See also pcHWRev and pcFWRev.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.6ColumnpcSubVendorread-onlymandatoryInteger sub-vendor ID for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.7ColumnpcSubProductread-onlymandatoryVendor's integer sub-product ID for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.8ColumnpcMaxBurstread-writemandatoryMaximum burst transfer rate in MBytes/second
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.9ColumnpcLatencyread-writemandatoryLatency Timer in Clock Ticks.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.10ColumnpcIdentifyread-writemandatoryReserved for flashing identifying LED on device.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.11ColumnpcPCIBusread-onlymandatoryPCI Bus number in SAN Data Gateway for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.12ColumnpcPCIDevread-onlymandatoryPCI device number in SAN Data Gateway for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.13ColumnpcPCIFuncread-onlymandatoryPCI Function number in SAN Data Gateway for this contoller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.14ColumnpcResetread-writemandatoryGeneric controller reset variable. Not supported for all controller types.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.15ColumnpcRescanread-writemandatoryWriting true(1) here causes controller to rescan its bus if rescan is supported for this controller type.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.16ColumnpcLEDread-onlymandatoryIs LED on?
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.17ColumnpcHWRevread-onlymandatoryHardware revision for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.18ColumnpcFWRevread-onlymandatoryFirmware revision for this controller
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.19ColumnpcPCISlotread-onlymandatoryLocation of Channel Card on PCI bus
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.20ColumnpcPMCSlotread-onlymandatoryLocation of Card: PMC 1, 2 or 3. 0=> Not a PMC card
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.21ColumnpcPCIClassread-onlymandatoryDevice class code as per PCI specification.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.22ColumnpcSplitModeread-writemandatoryEnable/Disable Split Mode for this controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.23ColumnpcChannelMaskread-writemandatorySpecifies access permissions for this initiator in bits 0 through 18 ************************************************* -* SCSI Channels *- Bit 0 => Is access D…
1.3.6.1.4.1.3764.1.1.400.10.10.4.1.1.24ColumnpcPortHostTyperead-writemandatoryHost type for this port. Used if VPS is not enabled.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2TablepcFCCtlrsnot-accessiblemandatoryEntry point for Fibre Channel Controller Device Group ****************************************************** This table parallels the Controller Table: a Fibre…
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1RowfcCtlrEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.1ColumnfcStatusread-onlymandatoryStatus of the Fibre Channel Controller
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.2ColumnfcMaxSpeedread-onlymandatoryMaximum Transfer Speed in MBytes per second.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.3ColumnfcWWIDread-onlymandatoryWorld Wide Identifier for this Fibre Channel Controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.4ColumnfcFWRevread-onlymandatoryFirmware revision number/identifier for this Fibre Channel Controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.5ColumnfcHWRevread-onlymandatoryHardware revision number/identifier for this Fibre Channel Controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.6ColumnfcLoopIDread-writemandatoryFibre Channel Loop ID. soft = -1
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.7ColumnfcFrameSizeread-writemandatoryFibre Channel frame size.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.8ColumnfcPortTyperead-writemandatoryFibre Channel Port Type
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.9ColumnfcMediaread-onlymandatoryMedia type for this Fibre Channel Controller
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.10ColumnfcSerialNumberread-onlymandatorySerial Number for this Fibre Channel Controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.11ColumnfcLoopIDModeread-onlymandatoryFibre Channel Loop ID mode (soft or hard)
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.12ColumnfcALPhysicalAddressread-onlymandatoryArbitrated Loop Physical Address (ALPA)
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.13ColumnfcPortModeread-writemandatoryFibre Channel Port Mode.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.14ColumnfcConnectionOptionsread-writemandatoryConnection options for ISP2200 FC chip. Values 4 - 8 are reserved.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.15ColumnfcCtlrChipTyperead-onlymandatoryType of Fibre Channel controller chip. Valid types are 2100 , 2200 for QLogic ISP2100 and ISP2200 chips.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.16ColumnfcTapeFeatureread-onlymandatoryStatus of Fibre Channel Tape Specification support. true means this controller supports FC Tape false means this controller does not support FC Tape
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.17ColumnfcHardIDread-writemandatoryFibre Channel Hard ID, the preferred loop ID for this controller. Even if the controller is in Hard Loop ID mode, the actual loop ID is not guaranteed to be fc…
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.18ColumnfcCurrentSpeedSettingread-writemandatorySpeed in Gb/sec. 0: Auto, 1: 1Gb, 2: 2Gb
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.19ColumnfcCurrentSpeedread-onlymandatoryCurrent Speed Indicator Gb/sec.
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.20ColumnfcFrameBufferSizeread-onlymandatoryFibre Channel Frame Buffer Size
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.21ColumnfcLinkFailureCountread-onlymandatoryFibre Channel Link Failure Count
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.22ColumnfcLossSyncCountread-onlymandatoryFibre Channel Loss of Sync Count
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.23ColumnfcLossSignalCountread-onlymandatoryFibre Channel Loss of Signal Count
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.24ColumnfcProtocolErrorCountread-onlymandatoryFibre Channel Primitive Sequence Protocol Error Count
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.25ColumnfcInvalidTxWordCountread-onlymandatoryFibre Channel Invalid Transmission Word Count
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.26ColumnfcInvalidCRCCountread-onlymandatoryFibre Channel Invalid CRC Count
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.27ColumnfcWWNodeNameread-onlymandatoryThe World Wide Node Name for this Fibre Channel Controller. The Node Name for this port may computer strictly on the World Wide Node Name for the gateway, or o…
1.3.6.1.4.1.3764.1.1.400.10.10.4.2.1.28ColumnfcPortIDread-onlymandatoryFibre Channel Port Identifier 24 bit quantity which uniquely identifies the port within the loop or fabric.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3TablepcSSACtlrsnot-accessibleobsoleteEntry point for SSA Controller Device Group **************************************************** This table parallels the Controller Table: an SSA controller w…
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1RowssaCtlrEntrynot-accessibleobsolete
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.1ColumnssaStatus1read-onlymandatoryStatus on port 1 of dual port SSA card
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.2ColumnssaStatus2read-onlymandatoryStatus on port 2 of dual port SSA card
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.3ColumnssaSpeedread-writemandatorySSA transfer speed 80 Mbytes/second or 160 MBytes/second
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.4ColumnssaUIDread-onlymandatoryUniversal Identifier for this SSA Controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.5ColumnssaFWRevread-onlymandatoryFirmware revision number/identifier for this SSA controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.6ColumnssaMaxTargread-writemandatoryMaximum number of targets supported.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.7ColumnssaMaxInitread-writemandatoryMaximum number of initiators supported.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.8ColumnssaPathAlgread-writemandatorySSA pathing algorithm.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.9ColumnssaHWRevread-onlymandatoryHardware revision number/identifier for this SSA controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.10ColumnssaMasterPriorityread-onlymandatoryThe SSA Master Priority of an SSA node is a number from 0 to 7. SSA initiators elect a master based on this priority. If more than one SSA node has the same pr…
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.11ColumnssaSATAQuotaread-onlymandatoryThe SSA SAT Quota A parameter is an 8 bit number that determines 'the maximum number of frames which can be originated from this port before the port is SATisf…
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.12ColumnssaSATBQuotaread-onlymandatoryThe SSA SAT Quota B parameter is an 8 bit number that determines 'the maximum number of frames which this port can originate without forwarding a SAT character…
1.3.6.1.4.1.3764.1.1.400.10.10.4.3.1.13ColumnssaSATIQuotaread-onlymandatory
1.3.6.1.4.1.3764.1.1.400.10.10.4.4TablepcSCSICtlrsnot-accessiblemandatoryEntry point for SCSI Controller Device Group **************************************************** This table parallels the Controller Table: a SCSI controller …
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1RowscsiCtlrEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.1ColumnscsiStatusread-onlymandatoryStatus for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.2ColumnscsiSpeedread-writemandatorySCSI Transaction speed.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.3ColumnscsiRoleread-writemandatoryIs this a Target or an Initiator ?
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.4ColumnscsiHostIdread-writemandatoryHost ID defaults to 7.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.5ColumnscsiMaxSpeedread-writemandatoryMaximum Speed of this SCSI Channel.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.6ColumnscsiTermread-writemandatoryState of internal SCSI bus terminations, if any.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.7ColumnscsiIoCardread-onlymandatoryType of SCSI controller hardware.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.8ColumnscsiMaxIdsread-writemandatoryMaximum Number of IDs for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.9ColumnscsiMaxLunsread-writemandatoryMaximum Number of LUNs for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.10ColumnscsiMaxWidthread-onlymandatoryMaximum transfer width in bits.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.11ColumnscsiHWRevread-onlymandatoryHardware revision for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.12ColumnscsiFWRevread-onlymandatoryFirmware revision for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.13ColumnscsiResetOnPowerUpread-writemandatoryEnables/Disables SCSI bus reset upon Gateway power-up for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.14ColumnscsiMultiInitEnabledread-writemandatoryEnables/Disables multi-initiator support on for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.15ColumnscsiAlternateHostIdread-writemandatoryAlternate Host ID for this SCSI controller. -1 means use automatic.
1.3.6.1.4.1.3764.1.1.400.10.10.4.4.1.16ColumnscsiTargetEnabledread-onlymandatoryIndicates target ScsiRole support for this SCSI controller.
1.3.6.1.4.1.3764.1.1.400.10.10.5Nodenotification
1.3.6.1.4.1.3764.1.1.400.10.10.5.1TablepnTrapDestnot-accessibleobsoleteTrap destination Group Table ****************************************** A list of IP addresses to which SNMP Traps are sent in parallel using UDP Port 162.
1.3.6.1.4.1.3764.1.1.400.10.10.5.1.1RowpnTrapDestEntrynot-accessibleobsolete
1.3.6.1.4.1.3764.1.1.400.10.10.5.1.1.1ColumnpnIndexread-writeobsoleteIndex into TrapDest table
1.3.6.1.4.1.3764.1.1.400.10.10.5.1.1.2ColumnpnIPAddrread-writeobsoleteIP Address of destination entity to which traps are sent.
1.3.6.1.4.1.3764.1.1.400.10.10.5.1.1.3ColumnpnUdpPortread-writeobsoleteUDP Port on which traps are sent to this entity.
1.3.6.1.4.1.3764.1.1.400.10.10.5.1.1.4ColumnpnTrapStyleread-writeobsoleteStyle to be used when building a trap PDU to be sent to this entity. A value of proprietary(1) selects the proprietary format used by the Pathlight SAN Directo…
1.3.6.1.4.1.3764.1.1.400.10.10.5.1.1.5ColumnpnTrapBroadcastModeread-writemandatoryUsed to Enable/Disable the broadcasting of traps.
1.3.6.1.4.1.3764.1.1.400.10.10.6NodepanelLED
1.3.6.1.4.1.3764.1.1.400.10.10.7NodepaHost
1.3.6.1.4.1.3764.1.1.400.10.10.7.1TablehostCommandTablenot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.7.1.1RowhostCommandEntrynot-accessiblemandatoryAn object for issuing host-related commands to the SNC.
1.3.6.1.4.1.3764.1.1.400.10.10.7.1.1.1ColumnhostCommandread-writemandatoryUsed to issue commands to VPS control software. Possible commands are: commitChanges: commits any pending LUN Mapping changes to persistent memory.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2TablehostInitiatornot-accessiblemandatoryAttached Host Group Table *************************** List of attached hosts and pertinent information.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1RowhostInitiatorEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.1ColumnhostIndexread-writemandatoryIndex into Host Initiator table
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.2ColumnhostRowStatusread-writemandatoryRow Status for this row.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.3ColumnhostWWNameread-writemandatoryWorld Wide name of this Initiator.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.4ColumnhostNameread-writemandatoryName for this Initiator.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.5ColumnhostTyperead-writemandatoryOperating System and other host environment information.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.6ColumnhostPortIDread-writemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.7ColumnhostSANConnectionread-onlymandatorySAN Connection (1-6) to which this host is connected.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.8ColumnhostConnectionTyperead-onlymandatoryType of data connection (FCAL , etc.)
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.9ColumnhostITLDataread-writemandatoryITL Access Control data for this host. 256 possible LUNs with one Byte of data per LUN.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.10ColumnhostIPAddrread-onlymandatoryIP Address of this host. Host is not required to have an IP address.
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.11ColumnhostLunTyperead-writemandatoryThe type of this host for EVPS. 8-bit, 16-bit, or volume set
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.12ColumnhostLunMapread-writemandatoryEVPS Map data. 256 possible LUNs with two Bytes of data for each lun
1.3.6.1.4.1.3764.1.1.400.10.10.7.2.1.13ColumnhostInbandAccessread-writemandatoryThe in-band access level of the host
1.3.6.1.4.1.3764.1.1.400.10.10.8NodescsiMap
1.3.6.1.4.1.3764.1.1.400.10.10.8.1TablescsiMapCommandTablenot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.8.1.1RowscsiMapCommandEntrynot-accessiblemandatoryAn object for issuing VPM-related commands to the SNC.
1.3.6.1.4.1.3764.1.1.400.10.10.8.1.1.1ColumnscsiMapCommandread-writemandatoryUsed to issue commands to SCSI Channel map (VPM) routines.
1.3.6.1.4.1.3764.1.1.400.10.10.8.2TablescsiChannelMapnot-accessiblemandatorySCSI Channel Device Map Table ****************************** List of devices presented to SCSI attached initiator. The initiator sees a series of (Target ID , …
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1RowscsiMapEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.1ColumnscsiMapRowStatusread-writemandatorySpecifies the state of the row.
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.2ColumnscsiMapPortread-onlymandatorySCSI port (bus) number for this entry (1 thru 10).
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.3ColumnscsiMapTidread-onlymandatorySCSI Target ID for this entry.
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.4ColumnscsiMapLunread-onlymandatorySCSI LUN for this entry.
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.5ColumnscsiMapAssignedLunread-writemandatoryPathlight LUN assigned to this entry. This assigned LUN maps to some device connected to the Gateway/Router by some other means (FC, SSA, SCSI, ...).
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.6ColumnscsiMapCommentsread-writemandatoryUser's comments for this entry.
1.3.6.1.4.1.3764.1.1.400.10.10.8.2.1.7ColumnscsiMapPdIndexread-onlymandatoryIndex into Pathlight SANMgr MIB Device Table ( pd group ). The Device Table has more detailed information about attached devices.
1.3.6.1.4.1.3764.1.1.400.10.10.9NodedeviceMap
1.3.6.1.4.1.3764.1.1.400.10.10.9.1TabledeviceMapCommandTablenot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.9.1.1RowdeviceMapCommandEntrynot-accessiblemandatoryAn object for issuing VPM-related commands to the SNC.
1.3.6.1.4.1.3764.1.1.400.10.10.9.1.1.1ColumndeviceMapCommandread-writemandatoryUsed to issue commands to device map map routines.
1.3.6.1.4.1.3764.1.1.400.10.10.9.1.1.2ColumndeviceMapMultipathModeread-writemandatoryUsed to set the Multipath mode.
1.3.6.1.4.1.3764.1.1.400.10.10.9.1.1.3ColumndeviceMapRemoveDevicewrite-onlymandatoryUsed to remove a device from the Device Map given its Device-Id. Warning: This command stops the IO for this device before removing
1.3.6.1.4.1.3764.1.1.400.10.10.9.1.1.4ColumndeviceLoadBalancingModeread-writemandatoryUsed to set the Load Balancing Mode.
1.3.6.1.4.1.3764.1.1.400.10.10.9.2TabledmDeviceMapnot-accessiblemandatoryDevice Map Group *********************************** Each device attached to the Gateway has an entry here. Historical data of devices not presently connected …
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1RowdmDevMapEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.1ColumndmRowStatusread-writemandatoryRow Control Object for this row
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.2ColumndmAssignedLunread-onlymandatoryLogical Unit Number assigned to this attached device. Range is 0 thru 255.
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.3ColumndmTyperead-writemandatoryType of device (FC, SCSI, SNA, SSA).
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.4ColumndmPortread-writemandatorySAN Gateway Port to which this device is connected. May be 1 thru 10 for SCSI, 1 thru 6 for Fibre Channel, 1 thru 3 for SSA.
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.5ColumndmTargetIdread-writemandatoryThe Target ID of the attached target device. This is the actual target ID of the device, not fabricated by the Gateway or Router.
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.6ColumndmTargetLunread-writemandatoryThe Logical Unit Number of the attached target device. This is the actual LUN of the device, not fabricated by the Gateway or Router.
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.7ColumndmUidread-writemandatoryA universally unique identifier for this target device.
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.8ColumndmPathread-onlymandatoryThe Multipath Mode of the device. The mode can only be single(0), manual(1), or auto(1).
1.3.6.1.4.1.3764.1.1.400.10.10.9.2.1.9ColumndmSerialNumread-onlymandatoryThe Serial Number of the device.
1.3.6.1.4.1.3764.1.1.400.10.10.10Nodereplication
1.3.6.1.4.1.3764.1.1.400.10.10.10.1TablesrsDevTablenot-accessiblemandatoryEntry point for SAN Replication Service Device Group ***************************************************** Each SAN Replication Service Device has an entry in …
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1RowsrsDevEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.1ColumnsrsDevIdread-onlymandatoryDevice ID for this SRS Device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.2ColumnsrsDevStateread-onlymandatoryState of this LUN Replicated Device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.3ColumnsrsDevCommandread-writemandatoryUsed to invoke SAN Replication Services API commands. Parameters may be passed in the same SNMP Set varbind list with the srsDevCommand as the last varbind. **…
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.4ColumnsrsDevAssignedLunread-writemandatoryAssigned LUN of the SAN Replication Service Device's Primary.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.5ColumnsrsDevMemberCountread-onlymandatoryNumber of members of this LUN Replicated Device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.6ColumnsrsDevMembersOnlineread-onlymandatoryNumber of members online.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.7ColumnsrsDevFlagsread-writemandatorySCSI device flags for this SAN Replication Service Device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.8ColumnsrsDevSizeInBlocksread-writemandatorySize in blocks of this SAN Replication Services Device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.9ColumnsrsDevBlockSizeread-writemandatoryBlock size in octets.
1.3.6.1.4.1.3764.1.1.400.10.10.10.1.1.10ColumnsrsDevPrimaryread-writemandatoryThe Assigned LUN of this SRS Device's Primary.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2TablesrsMemTablenot-accessiblemandatoryEntry point for SAN Replication Services Member Group ***************************************************** This table lists the Members of each SRS Device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1RowsrsMemEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.1ColumnsrsMemDeviceIdread-onlymandatoryDevice ID of the SAN Replication Services Device to which this member belongs.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.2ColumnsrsMemIdread-onlymandatoryMember ID (index) of this member device.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.3ColumnsrsMemStateread-onlymandatoryState of this SAN Replication Services Device Member.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.4ColumnsrsMemCommandread-writemandatoryUsed to invoke SAN Replication Services API methods. Parameters may be passed in the same SNMP Set varbind list with the lrmCommand as the last varbind.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.5ColumnsrsMemTyperead-onlymandatoryIs this device a primary or secondary member.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.6ColumnsrsMemSyncPointread-onlymandatoryNumber of blocks synchronized so far. Used for monitoring synchronization.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.7ColumnsrsMemAssignedLunread-writemandatoryAssigned LUN for this SRS Member.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.8ColumnsrsMemReadOptionsread-writemandatorySRS Member read options.
1.3.6.1.4.1.3764.1.1.400.10.10.10.2.1.9ColumnsrsMemWriteOptionsread-writemandatorySRS Member write options.
1.3.6.1.4.1.3764.1.1.400.10.10.11NodeenvData
1.3.6.1.4.1.3764.1.1.400.10.10.11.1TableenvDataTablenot-accessiblemandatoryEntry point for Environmental Data Group ***************************************************** This table lists the attributes of each environmental data.
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1RowenvDataEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.1ColumnenvDataIdread-onlymandatory
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.2ColumnenvDataNameread-onlymandatoryName of this environmental data
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.3ColumnenvNominalLoread-onlymandatoryMinimum value for Nominal status Warning state occurs if the current value is less than this
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.4ColumnenvNominalHiread-onlymandatoryMaximum Value for Nominal status Warning state occurs if the current value is greater than this.
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.5ColumnenvWarningLoread-onlymandatoryMinimum value for Warning status Alarm state occurs if the current value is less than this
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.6ColumnenvWarningHiread-onlymandatoryMaximum Value for Warning status Alarm state occurs if the current value is greater than this.
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.7ColumnenvCurValueread-onlymandatoryCurrent Value.
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.8ColumnenvCurStatusread-onlymandatoryCurrent Status: Nominal, Warning, or Alarm.
1.3.6.1.4.1.3764.1.1.400.10.10.11.1.1.9ColumnenvUnitread-onlymandatoryUnit
1.3.6.1.4.1.3764.1.1.400.10.10.12NodeportFailover
1.3.6.1.4.1.3764.1.1.400.10.10.12.1NodefcHostPortFailover
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1TablefcHPFPortMappingsnot-accessiblemandatoryFC Host Port Failover Mapping *********************************** This table consists of port mappings for the FC Host Port Failover
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1.1RowfcHPFMapEntrynot-accessiblemandatorySNMP table for FC Host Port Failover Mappings
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1.1.1ColumnfcHPFMapRowStatusread-writemandatoryRow Control Object for this row
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1.1.2ColumnfcHPFMapVirtualPortread-writemandatoryThe virtual port index. Depends on the configuration. Usaually same as phys port index, but 0 if not configured
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1.1.3ColumnfcHPFMapPrimaryPortread-writemandatoryThe physical port index that acts as the default standby
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1.1.4ColumnfcHPFMapStandbyListread-writemandatoryThe comma seperated list of ports that are configured as standbys for the virtual port, excluding the primary port.
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.1.1.5ColumnfcHPFMapActivePortread-writemandatoryThe physical port thats active on this virtual port
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2TablefcHPFPhysicalPortsnot-accessiblemandatoryFC Host Port Failover Physical Ports *************************************** This table consists of physical port settings for the FC Host Port Failover
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2.1RowfcHPFPhysicalPortEntrynot-accessiblemandatorySNMP table for FC Host Port Failover Port Settings
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2.1.1ColumnfcHPFPhysicalPortRowStatusread-writemandatoryRow Control Object for this row
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2.1.2ColumnfcHPFPhysicalPortread-onlymandatoryThe physical FC port Index. The range depends on the pathlight model.
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2.1.3ColumnfcHPFPhysicalPortFailureTyperead-onlymandatoryIf this phys port failed, this field gives the type of failure.Values 0 = None, 1 = Link Down 2 = Link Error
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2.1.4ColumnfcHPFPhysicalPortCurrentStateread-onlymandatoryThe current state of this physical port. The values 0 = Online, 1 = Offline
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.2.1.5ColumnfcHPFPhysicalPortInterventionread-writemandatoryDoes this physical port require intervention? Values 1 = true, 2 = false
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.3TablefcHPFGlobalTablenot-accessiblemandatoryFC Host Port Failover Global Settings **************************************** This table consists of settings global to the HPF function.
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.3.1RowfcHPFGlobalEntrynot-accessiblemandatorySNMP table for FC Host Port Failover Global Settings
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.3.1.1ColumnfcHPFLinkDownThresholdread-writemandatoryUsed to set the Link Down threshold in seconds. Only after this delay the failover triggers
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.3.1.2ColumnfcHPFErrorRecoveryModeread-writemandatoryUsed to set the global recovery mode for failures that happen due to FC cable errors Values: returnToActive(0), returnToStandby(1), requiresIntervention(2)
1.3.6.1.4.1.3764.1.1.400.10.10.12.1.3.1.3ColumnfcHPFLinkDownRecoveryModeread-writemandatoryUsed to set the global recovery mode for failures that happen due to Link Down Errors Values: returnToActive(0), returnToStandby(1), requiresIntervention(2)
1.3.6.1.4.1.3764.1.1.400.10.10.13NodeutilityModule
1.3.6.1.4.1.3764.1.1.400.10.10.13.1TableutilityModuleTablenot-accessiblemandatoryEntry point for Utility Module Group *****************************************************
1.3.6.1.4.1.3764.1.1.400.10.10.13.1.1RowutilityModuleEntrynot-accessiblemandatory
1.3.6.1.4.1.3764.1.1.400.10.10.13.1.1.1ColumnutilityModuleIdread-onlymandatoryUtility module index.
1.3.6.1.4.1.3764.1.1.400.10.10.13.1.1.2ColumnutilityModuleVersionread-onlymandatoryUtility module version identifier.
1.3.6.1.4.1.3764.1.1.400.10.10.1000NodetrapDefinition
1.3.6.1.4.1.3764.1.1.400.10.10.1000.1NodessaPortUpEventAn SSA Port Up Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.2NodessaPortDownEventAn SSA Port Down Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.3NodessaUidAddedEventAn SSA UID Added Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.4NodessaUidRemovedEventAn SSA UID Removed Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.5NodessaWebReconfiguredEventAn SSA Web Reconfigured Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.6NodessaAsyncErrorEventAn SSA Async Error Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.7NodessaAdapterEventAn SSA Adapter Event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.8NodesenseDataEventSense Data recorded following a check condition. Normally, the host system will request and process sense data, and then perform error recovery.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.9NodeunitAttentionEventA LUN reports a unit attention condition on a non-removable media device.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.10NodeibfEventAn Internal Bus Fault event has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.11NodetemperatureChangeEventA temperature sensor has reported a change from one of three possible states to a another. The possible states are OK, High, Very High. The display string cont…
1.3.6.1.4.1.3764.1.1.400.10.10.1000.12NodetimeReferenceEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.13NodeshutdownEventThis unit is shutting down as a result of a restart request.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.14NodediagnosticEventThis event is used for diagnostic purposes.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.15NodeconfigurationEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.16NodeunexpectedScsiInterruptEventA SCSI bus reports an unexpected interrupt.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.17NodelipResetEventA Fibre Channel interface reports a LIP reset was received from a host.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.18NodefcSystemErrorEventA Fibre Channel interace reports a system error.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.19NodefcRequestTransferErrorEventA Fibre Channel interface reports an error processing a request.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.20NodefcResponseTransferErrorEventA Fibre Channel interface reports an error processing a response.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.21NodememoryFaultEventProcessor memory fault detected.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.22NodefcLipEventA Fibre Channel interface detected a LIP.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.23NodefcLoopUpEventA Fibre Channel interface reports loop up.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.24NodefcLoopDownEventA Fibre Channel interface reports loop down.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.25NodepciBusParityErrorEventParity error detected on unit internal PCI bus.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.26NodepciInterfaceErrorEventInterface error detected on unit internal PCI bus.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.27NodescsiDeviceAddedEventA device has been added to a SCSI bus.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.28NodescsiBusResetEventA SCSI interface reports a bus reset was detected.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.29NodedeviceAddedEventThis unit has added a device to its configuration table. Note: This trap is held off until the unit has been up for 60 seconds.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.30NodedeviceRemovedEventThis unit has removed a device from its configuration table.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.31NodeloggingStartedEventEvent logging service has started.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.32NodeloggingStoppedEventEvent logging service has stopped.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.33NodeinterfaceBusFaultEventAn interface has detected a bus fault. The display string contained in varbind paEventVars contains the details of which interface detected the fault.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.34NodeinterfaceDeviceFaultEventAn interface has detected a device fault. The display string contained in varbind paEventVars contains the details of which interface detected the fault.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.35NodescsiUnexpectedDisconnectEventA SCSI interface has reported an unexpected disconnect by a device.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.36NodescsiParityErrorEventA SCSI interface has detected a parity error on the bus.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.37NodefcPortDatabaseChangeEventFibre Channel port databse change detected.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.38NodeddfMemoryErrorEventAn error was detected on the Direct Data Flow memory board.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.39NodefcDirectoryServerChangeEventThe Directory Server on the Fibre Channel fabric has changed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.40NodelunLimitExcededEventThe maximum LUN limit has been exceded, too many devices connected.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.41NodefcTransferFailureEventFibre Channel transfer error.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.42NodedeviceLimitExcededEventThe maximum device limit has been exceded, the persistent device map database is full.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.43NodefcDebugDumpEventA Fibre Channel interface driver has reported a a debug dump.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.44NodeexcessiveScsiBusErrorsEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.45NodememoryScrubberErrorEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.46NodesrsDeviceCreatedEventA new SAN Replication Services device has been created
1.3.6.1.4.1.3764.1.1.400.10.10.1000.47NodesrsDeviceOnlineEventA SAN Replication Services device has entered the online state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.48NodesrsDeviceRemovedEventA SAN Replication Services device has been removed (deleted).
1.3.6.1.4.1.3764.1.1.400.10.10.1000.49NodesrsDeviceFailedEventA SAN Replication Services device has failed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.50NodesrsMemberAddedEventA new member LUN has been added to a SAN Replication Services device.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.51NodesrsMemberSuspendedEventA SAN Replication Services member has been suspended.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.52NodesrsMemberRemovedEventA SAN Replication Services member has been removed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.53NodesrsMemberSyncStartedEventA SAN Replication Service member has begun synchronization to the primary member.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.54NodesrsMemberSyncDoneEventA SAN Replication Service member has completed synchronization to the primary member.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.55NodesrsMemberSyncErrorEventAn error was detect during synchronization of a SAN Replication Service member to the primary member.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.56NodesrsMemberRetryEventA command issued to a SAN Replication Services member has failed and is being retried.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.57NodesrsMemberErrorEventA command issued to a SAN Replication Services member has resulted in an error.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.58NodeenvPowerNominalEventPower has returned to nominal state from a warning or alarm state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.59NodeenvPowerWarningEventPower has entered a warning state from a nominal state (power degrading) or alarm state (power improving).
1.3.6.1.4.1.3764.1.1.400.10.10.1000.60NodeenvPowerAlarmEventPower has entered an alarm state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.61NodeenvTemperatureNominalEventInlet air, outlet air, or I/O processor temperature has returned to nominal state from a warning or alarm state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.62NodeenvInletTemperatureWarningEventInlet air temperature has entered a warning state from a nominal state (temperature increasing) or an alarm state (temperature decreasing).
1.3.6.1.4.1.3764.1.1.400.10.10.1000.63NodeenvInletTemperatureAlarmEventInlet air temperature has entered an alarm state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.64NodeenvOutletTemperatureWarningEventOutlet air temperature has entered a warning state from a nominal state (temperature increasing) or an alarm state (temperature decreasing).
1.3.6.1.4.1.3764.1.1.400.10.10.1000.65NodeenvOutletTemperatureAlarmEventOutlet air temperature has entered an alarm state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.66NodeenvFanNominalEventFan has entered a nominal state from a fault state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.67NodeenvFanWarningEventFan has entered a warning range (tachometer fans only).
1.3.6.1.4.1.3764.1.1.400.10.10.1000.68NodeenvFanAlarmEventFan has entered an alarm range (tachometer fans) or is stalled (rotor stall fans).
1.3.6.1.4.1.3764.1.1.400.10.10.1000.69NodeeccMemoryErrorEventError correcting code memory has detected an error.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.70NoderestartCompleteEventRestart process has completed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.71NodefirmwareUploadCompleteEventFirmware upload process has completed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.72NodemaxInitiatorsExceededEventMaximum number of initiators has been exceeded.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.73NodedataPathFailoverEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.74NodeamemWarningEventAmem memory not properly installed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.75NodehostOfflineEventAn attached host has been moved to the offline state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.76NodehostOnlineEventAn attached host has been moved to the online state.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.77NodehostPortFailoverEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.78NodehpfRequiresInterventionEventHost port failover requires invention.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.79NodecontrollerResetCompletedEventThe controller indicated in paEventVars has completed its reset sequence. The text format for paEventVars is: NOTICE: FC Controller %d Restart Complete
1.3.6.1.4.1.3764.1.1.400.10.10.1000.80NodecontrollerStatusChangeEventThe status of the controller indicated in paEventVars has changed. The controller index (pcIndex) and the new status (fcStatus for Fibre Channel, scsiStatus fo…
1.3.6.1.4.1.3764.1.1.400.10.10.1000.81NodeethFailoverEventEthernet Port Filover has occured.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.82NodememUsageWarningEventMemory usage reached warning level.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.83NodetaskSuspendedWarningEventTask suspended warning.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.84NodeumTaskWatchdogWarningEventUtility module task watchdog warning.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.85NodedataPathTrespassEventData path trespass has occurred.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.86NodedeviceListChangedEventTarget device list changed on an interface.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.87NodeautoLevelStartAuto Level has begun.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.88NodeautoLevelEndAuto Level is done.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.89NodeautoLevelErrorAuto Level has got error.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.90NodecorruptNVRAMErrorNVRAM corruption detected.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.100NodepowerSupplyOutOfSpecEventThe main power supply voltage is out of specified operating range.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.101NodeauxPowerOutOfSpecEventThe auxillary power supply voltage is out of specified operating range.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.102NodenewTemperatureChangeEventTemperature change detected since last report. The possible temperature states are OK, High, and Very High.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.103NodenewPciErrorsEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.104NodenewMemoryParityErrorsEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.105NodepciBusInterfaceErrorEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.106NodefcInterfaceFailureEventFibre Channel interface failed Health Check.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.107NodescsiInterfaceFailureEventSCSI interface failed Health Check.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.108NodessaInterfaceFailureEventSSA interface failed Health Check.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.109NodedeviceFailureEventTarget device failed Health Check.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.110NodefcLinkStatusChangeEventFibre Channel link status has changed.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.111NodenewFcTranferErrorsEventNew Fibre Channel transfer errors were detected since last report.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.112NodeenvFanEventThe health check task has detected a fan running in warning or alarm range.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.113NodeenvPowerEventThe health check task has detected a power supply running in warning or alarm range.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.114NodeenvTemperatureEventThe health check task has detected a temperature sensor reporting in warning or alarm range.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.115NodeeccMemoryHealthCheckEventThe health check task has detected an ECC memory error.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.116NodeeccMemoryScrubberEventThe health check task has detected an ECC memory scrubber event.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.118NodedeviceRecoverEvent
1.3.6.1.4.1.3764.1.1.400.10.10.1000.150NodelogWillOverwriteEventThe event log circular buffer is about to wrap, overwriting the oldest entries.
1.3.6.1.4.1.3764.1.1.400.10.10.1000.4444NodebootCompletedEventThis unit has completed its boot sequence and is ready for SNMP communication with management applications. During the time period between the initiation of th…
Type Definitions
NameSyntaxStatusDescription
BooleanINTEGER { true(1), false(2) }
DeviceTypeINTEGER{ directAccess(0), sequentialAccess(1), printer(2), processor(3), worm(4), cd(5), scanner(6), opticalMemory(7), mediumChanger(8), communications(9), ascIt81(10), ascIt82(11), storageArrayController(12), enclosure(13), simplifiedDirectAccess(14), opticalCardReader(15), unknown(31) }
FcHPFPortFailTypeINTEGER {none(0), linkDown(1), linkError(2)}
FcHPFPortStateINTEGER {onLine(0), offLine(1)}
FcHPFRecoveryTypeINTEGER {returnToActive(0), returnToStandby(1), requiresIntervention(2)}
FcStatusINTEGER { configWait(0), loopInit(1), login(2), ready(3), lostSync(4), error(5), reinit(6), nonPart(7), failed(8) }
FibreConnOptionsINTEGER{ loopOnly(0), pointToPointOnly(1), loopPreferred(2), pointToPointPreferred(3) }
FibreLoopIDModeINTEGER{ soft(0) , hard(1) }
FibreMediaINTEGER{ unknown(0), copper(1), shortWaveOptical(2), longWaveOptical(3), shortWaveOpticalDual(4) , longWaveOpticalDual(5), shortWaveOpticalLongDistance(6) , longWaveOpticalLongDistance(7), gbicSWOneGB(8), gbicLW1300OneGB(9), gbicLW1300HPOneGB(10), gbicLW1550HPOneGB(11), gbicCopperHSSDCOneGB(12), gbicCopperDB9OneGB(13), gbicSWTwoGB(14), gbicLW1300TwoGB(15), gbicLW1300HPTwoGB(16), gbicLW1550HPTwoGB(17), gbicCopperHSSDCTwoGB(18), gbicCopperDB9TwoGB(19), noGBIC(20) , sfpSWTwoGB(21) }
FibrePortINTEGER{ nodeLoop(0) , node(1) , fabricLoop(3), fabric(4), none( 255 ) }
FibrePortModeINTEGER{ privateTargetOnly(1), privateInitiatorOnly(2), privateTargetAndInitiator(3), publicTargetOnly(17), publicInitiatorOnly(18), publicTargetAndInitiator(19) }
HostLUNTypeINTEGER {bit8(0), bit16(1), vsa(2)}
InterfaceINTEGER { none(0), sanGateway(1), ssa(2), fibreChannel(3), scsi(4), ethernet(5), unknown(6), any(7) , sanReplication(8), vLib(9), soip(10), soip2(11) }
PathlightProductINTEGER{ sanGateway(1) , sanRouter(2) , sanBridge(3), adicFCR2(4), dellFCR2(5), siemensFCR2(6), sanHoneoye(7), adicHoneoye(8), dellHoneoye(9), siemensHoneoye(10), ibmGatewayModule(11), ibmHoneoye(12), adicPlt5000(13), dellPlt5000(14), ibmPlt5000(15), adicSNC4000(16), dellSNC4000(17), adicSNC6101(18), dellSNC6101(19), adicSNC6404(20), adicSNC6104(21) }
PltStatusINTEGER { failed(1), down(2), testing(3), up(4) }
ResetINTEGER { run(0) , reset(1) , reboot(2) }
RowStatusINTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) }
ScsiAnsiLevelINTEGER{ notScsi(0) , scsi-1(1), scsi-2(2) , scsi-3(3) }
ScsiCardTypeINTEGER{ none(0), differentialNoTermination(1), differentialTerminated(2), singleEndedNoTermination(3), singleEndedTerminated(4), unknown(5), lowVoltageSingleEnded(6), lowVoltageDifferential(7), lowVoltageMultiFunction(8) }
ScsiSpeedINTEGER { async(0), fast(1), ultra(2) , ultra2(3) , ultra160(4) , ultra320(5) }
VendorIDIntINTEGER{ unknown(0) , symbios(4096) , amd(4130) , qlogic(4215) , pathlight(4537) }