MIB Viewer
MIB Viewer Desktop New

ARICENT-ISS-MET-MIB

17 objects
The enterprise ID 2076 was originally assigned to Future Software Pvt Limited. Future Software is a part of Aricent.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2076.81.8.4IdentityissMetThe enterprise ID 2076 was originally assigned to Future Software Pvt Limited. Future Software is a part of Aricent.
1.3.6.1.4.1.2076.81.8.4.1NodeissMetroL2Filter
1.3.6.1.4.1.2076.81.8.4.1.1TableissMetroL2FilterTablenot-accessiblecurrentA table to configure L2 filter rules defined for the metro ethernet features of the switch.
1.3.6.1.4.1.2076.81.8.4.1.1.1RowissMetroL2FilterEntrynot-accessiblecurrentEach entry in this table is a L2 filter rule. Index to the table is the L2 filter number. An entry in this table will be created when the L2 Filter entry (issL…
1.3.6.1.4.1.2076.81.8.4.1.1.1.1ColumnissMetroL2FilterOuterEtherTyperead-writecurrentSpecifies the Ether type of the Outer VLAN tag of a packet. By Default, the value of the Outer Ether type will be zero, which means dont care condition ie) Pac…
1.3.6.1.4.1.2076.81.8.4.1.1.1.2ColumnissMetroL2FilterSVlanIdread-writecurrentService Vlan Id / Outer Vlan Id / Vlan Id present in Outer tag to be filtered. A value of '0' means, the service Vlan Id becomes dont care
1.3.6.1.4.1.2076.81.8.4.1.1.1.3ColumnissMetroL2FilterSVlanPriorityread-writecurrentService Vlan Priority / Outer Vlan Priority / Vlan Priority present in Outer tag to be filtered. A value of '-1' means, the Service Vlan priority becomes dont …
1.3.6.1.4.1.2076.81.8.4.1.1.1.4ColumnissMetroL2FilterCVlanPriorityread-writecurrentCustomer Vlan Priority / Inner Vlan Priority / Vlan Priority present in Inner tag to be filtered. A value of '-1' means, the Customer Vlan priority becomes don…
1.3.6.1.4.1.2076.81.8.4.1.1.1.5ColumnissMetroL2FilterPacketTagTyperead-writecurrentSpecifies whether the configured filter parameters are applied on single VLAN tagged packets or double VLAN tagged packets. The default value for this field is…
1.3.6.1.4.1.2076.81.8.4.2NodeissMetroL3Filter
1.3.6.1.4.1.2076.81.8.4.2.1TableissMetroL3FilterTablenot-accessiblecurrentA table to configure L3 filter rules defined for the metro ethernet features of the switch.
1.3.6.1.4.1.2076.81.8.4.2.1.1RowissMetroL3FilterEntrynot-accessiblecurrentEach entry in this table is a L3 filter rule. Index to the table is L3 filter number. An entry in this table is created when issL3FilterStatus is created in fs…
1.3.6.1.4.1.2076.81.8.4.2.1.1.1ColumnissMetroL3FilterSVlanIdread-writecurrentService Vlan Id / Outer Vlan Id / Vlan Id present in Outer tag to be filtered. A value of '0' means, the Service Vlan Id becomes dont care
1.3.6.1.4.1.2076.81.8.4.2.1.1.2ColumnissMetroL3FilterSVlanPriorityread-writecurrentService Vlan Priority / Outer Vlan Priority / Vlan Priority present in Outer tag to be filtered. A value of '-1' means, the service vlan priority becomes dont …
1.3.6.1.4.1.2076.81.8.4.2.1.1.3ColumnissMetroL3FilterCVlanIdread-writecurrentCustomer Vlan Id / Inner Vlan Id / Vlan Id present in Inner tag to be filtered. A value of '0' means, the Customer Vlan Id becomes dont care
1.3.6.1.4.1.2076.81.8.4.2.1.1.4ColumnissMetroL3FilterCVlanPriorityread-writecurrentCustomer Vlan Priority / Inner Vlan Priority / Vlan Priority present in Inner tag to be filtered. A value of '-1' means, the customer vlan priority becomes don…
1.3.6.1.4.1.2076.81.8.4.2.1.1.5ColumnissMetroL3FilterPacketTagTyperead-writecurrentSpecifies whether the configured filter parameters are applied on single VLAN tagged packets or double VLAN tagged packets. The default value for this field is…