ASCEND-MIBCLTM-MIB
51 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.529.23.66 | NodemibcltmCmd | |||
| 1.3.6.1.4.1.529.23.66.1 | TablemibcltmCmdTable | not-accessible | mandatory | A list of mibcltmCmd profile entries. |
| 1.3.6.1.4.1.529.23.66.1.1 | RowmibcltmCmdEntry | not-accessible | mandatory | A mibcltmCmd entry containing objects that maps to the parameters of mibcltmCmd profile. |
| 1.3.6.1.4.1.529.23.66.1.1.1 | ColumncltmCmd-Index-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.66.1.1.2 | ColumncltmCmd-CltmSlot | read-only | mandatory | Identify the CLTM slot within the system. |
| 1.3.6.1.4.1.529.23.66.1.1.3 | ColumncltmCmd-TestTimeStamp | read-only | mandatory | Value of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are changed. |
| 1.3.6.1.4.1.529.23.66.1.1.4 | ColumncltmCmd-TestSequence | read-only | mandatory | Sequence of the last issued test command. |
| 1.3.6.1.4.1.529.23.66.1.1.5 | ColumncltmCmd-TestOperation | read-write | mandatory | The current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure. |
| 1.3.6.1.4.1.529.23.66.1.1.6 | ColumncltmCmd-DmmType | read-write | mandatory | DMM Measurement Type. |
| 1.3.6.1.4.1.529.23.66.1.1.7 | ColumncltmCmd-DmmLead | read-write | mandatory | DMM Measurement Leads. |
| 1.3.6.1.4.1.529.23.66.1.1.8 | ColumncltmCmd-BackgroundNoiseFilter | read-write | mandatory | Line Filter Type for Background Noise Test. |
| 1.3.6.1.4.1.529.23.66.1.1.9 | ColumncltmCmd-BackgroundNoiseTermination | read-write | mandatory | Line Termination Type for Background Noise Test. |
| 1.3.6.1.4.1.529.23.66.1.1.10 | ColumncltmCmd-LoopResistanceUnit | read-write | mandatory | Measurement System for Loop Resistance Test. |
| 1.3.6.1.4.1.529.23.66.1.1.11 | ColumncltmCmd-LoopResistanceTemp | read-write | mandatory | Line Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit. |
| 1.3.6.1.4.1.529.23.66.1.1.12 | ColumncltmCmd-ImpulseNoiseStartThresh | read-write | mandatory | Threshold for Impulse Noise Test. The Range is 50-100 dBrm. |
| 1.3.6.1.4.1.529.23.66.1.1.13 | ColumncltmCmd-ImpulseNoiseStartDelta | read-write | mandatory | Delta Value for Impulse Noise Test. The delta range is 2-6 dB |
| 1.3.6.1.4.1.529.23.66.1.1.14 | ColumncltmCmd-ImpulseNoiseStartMaxCount | read-write | mandatory | Max Count for Impulse Noise Test. The range of the value is 1-1999. |
| 1.3.6.1.4.1.529.23.66.1.1.15 | ColumncltmCmd-ImpulseNoiseStartDeadTime | read-write | mandatory | Dead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments. |
| 1.3.6.1.4.1.529.23.66.1.1.16 | ColumncltmCmd-ImpulseNoiseStartTimer | read-write | mandatory | Timer values for Impulse Noise Start Test. The value is assigned in 1 minute increment. |
| 1.3.6.1.4.1.529.23.66.1.1.17 | ColumncltmCmd-CalibrationType | read-write | mandatory | Calibration Type |
| 1.3.6.1.4.1.529.23.66.1.1.18 | ColumncltmCmd-ToneSendFreq | read-write | mandatory | Tone Send Frequency in KHz. |
| 1.3.6.1.4.1.529.23.66.1.1.19 | ColumncltmCmd-ToneSendLevel | read-write | mandatory | Tone Send Level in dBm. |
| 1.3.6.1.4.1.529.23.66.1.1.20 | ColumncltmCmd-ToneSendPeriod | read-write | mandatory | Amount of time a tone is sent (1-20 Minutes). |
| 1.3.6.1.4.1.529.23.66.1.1.21 | ColumncltmCmd-TdrUnit | read-write | mandatory | Measurement System for TDR Test. |
| 1.3.6.1.4.1.529.23.66.1.1.22 | ColumncltmCmd-TdrGauge | read-write | mandatory | TDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
| 1.3.6.1.4.1.529.23.66.1.1.23 | ColumncltmCmd-TdrVp | read-write | mandatory | TDR VP as percentage of the speed of light. |
| 1.3.6.1.4.1.529.23.66.1.1.24 | ColumncltmCmd-TdrAvg | read-write | mandatory | Number of trials to get the avarage. |
| 1.3.6.1.4.1.529.23.66.1.1.25 | ColumncltmCmd-TdrGetType | read-write | mandatory | TDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set. |
| 1.3.6.1.4.1.529.23.66.1.1.26 | ColumncltmCmd-TdrStartDistance | read-write | mandatory | TDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the metric system. |
| 1.3.6.1.4.1.529.23.66.1.1.27 | ColumncltmCmd-TdrMeasurementLength | read-write | mandatory | TDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) for the metric system. |
| 1.3.6.1.4.1.529.23.66.1.1.28 | ColumncltmCmd-DmmdcdPeriod | read-write | mandatory | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
| 1.3.6.1.4.1.529.23.66.1.1.29 | ColumncltmCmd-DmmdcdVoltage | read-write | mandatory | Test voltage to be used (-230 to 230 Volts). |
| 1.3.6.1.4.1.529.23.66.1.1.30 | ColumncltmCmd-DmmdcdImpedance | read-write | mandatory | Output Impedance to be used (10 to 1000 Kohms). |
| 1.3.6.1.4.1.529.23.66.1.1.31 | ColumncltmCmd-DmmcapPeriod | read-write | mandatory | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
| 1.3.6.1.4.1.529.23.66.1.1.32 | ColumncltmCmd-DmmallType | read-write | mandatory | DMM Measurement Type. |
| 1.3.6.1.4.1.529.23.66.1.1.33 | ColumncltmCmd-DmmallPeriod | read-write | mandatory | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
| 1.3.6.1.4.1.529.23.66.1.1.34 | ColumncltmCmd-DmmallInputImp | read-write | mandatory | Input Impedance (100, 1000 Kohm). |
| 1.3.6.1.4.1.529.23.66.1.1.35 | ColumncltmCmd-CtoneType | read-write | mandatory | Control tone, type of DSL service (ADSL, GLITE). |
| 1.3.6.1.4.1.529.23.66.1.1.36 | ColumncltmCmd-CtoneTone | read-write | mandatory | Control tone, type of Tone (QUIET, RESTORE). |
| 1.3.6.1.4.1.529.23.66.1.1.37 | ColumncltmCmd-TtoneLead | read-write | mandatory | trace tone, Measurement Leads. |
| 1.3.6.1.4.1.529.23.66.1.1.38 | ColumncltmCmd-TtoneLevel | read-write | mandatory | trace tone, Tone Send Level in dBm. |
| 1.3.6.1.4.1.529.23.66.1.1.39 | ColumncltmCmd-TtonePeriod | read-write | mandatory | trace tone, Amount of time a tone is sent (1-20 Minutes). |
| 1.3.6.1.4.1.529.23.66.1.1.40 | ColumncltmCmd-BtapStartLength | read-write | mandatory | Measurement start length (15 - 20000 ft. or 5 - 6097 meter). |
| 1.3.6.1.4.1.529.23.66.1.1.41 | ColumncltmCmd-BtapMeasureLength | read-write | mandatory | Measurement length (100 - 20000 ft. or 32 - 6097 meter). |
| 1.3.6.1.4.1.529.23.66.1.1.42 | ColumncltmCmd-Action-o | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.66.1.1.43 | ColumncltmCmd-FcllocUnit | read-write | mandatory | Measurement System for FCLLOC Test. |
| 1.3.6.1.4.1.529.23.66.1.1.44 | ColumncltmCmd-FcllocGauge | read-write | mandatory | FCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
| 1.3.6.1.4.1.529.23.66.1.1.45 | ColumncltmCmd-ShortlocUnit | read-write | mandatory | Measurement System for SHORTLOC Test. |
| 1.3.6.1.4.1.529.23.66.1.1.46 | ColumncltmCmd-ShortlocGauge | read-write | mandatory | SHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
| 1.3.6.1.4.1.529.23.66.1.1.47 | ColumncltmCmd-ShortlocType | read-write | mandatory | SHORTLOC test type. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |