MIB Viewer

ATM-SWITCHING-NODE-MIB

244 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.6NodeibmProd
1.3.6.1.4.1.2.6.33NodeatmSw
1.3.6.1.4.1.2.6.33.1Nodenode
1.3.6.1.4.1.2.6.33.1.1Nodebase
1.3.6.1.4.1.2.6.33.1.1.1ScalardateTimeread-writemandatoryThe local date and time in the ATM agent.
1.3.6.1.4.1.2.6.33.1.1.2ScalarlastChangeread-onlydeprecatedThe date and time of the last major change detected: - date and time reset - agent IP address(es), subnet mask(s), default gateway changed - LAN Emulation or I…
1.3.6.1.4.1.2.6.33.1.1.3Scalarlockread-writemandatoryThe purpose of this variable is to protect the path between the hub and the network management station. When set to secure (1), it is not possible to: - disabl…
1.3.6.1.4.1.2.6.33.1.1.4ScalaripArpServerAtmAddressread-writemandatoryThe ATM address of the ARP server used when communicating with the switch agent using Classical IP over ATM (RFC 1577).
1.3.6.1.4.1.2.6.33.1.1.6ScalarsystemStateread-writemandatoryThe state of the ATM subsystem. Setting this variable to reset, causes a reset of all the ATM modules. When the active switch is in slots 9/10, switch-a is ret…
1.3.6.1.4.1.2.6.33.1.2Nodetraps
1.3.6.1.4.1.2.6.33.1.2.1Scalarhelloread-writemandatoryWhen disabled, the hello trap is neither sent. When enabled, the hello trap can be sent by the agent when the appropriate trap condition is detected.
1.3.6.1.4.1.2.6.33.1.3NodechangeA change trap is sent when one of the following MIB variables or group of variables is changed: - Date and Time reset - System Parameters (name, contact, locat…
1.3.6.1.4.1.2.6.33.1.3Nodephysical
1.3.6.1.4.1.2.6.33.1.3.1TableswitchTablenot-accessiblemandatoryThis table controls slot attachement to the ATM switch. An ATM module is operational only when inserted in a slot which is defined as attached to the switch.
1.3.6.1.4.1.2.6.33.1.3.1.1RowswitchEntrynot-accessiblemandatoryEntries of switchTable. Each entry corresponds to a slot that is physically wired to the switch. These slots may be attached to or isolated from the ATM switch.
1.3.6.1.4.1.2.6.33.1.3.1.1.1ColumnswitchSlotIndexread-onlymandatoryA slot number controlled by the switch.
1.3.6.1.4.1.2.6.33.1.3.1.1.2ColumnswitchAdminStateread-writemandatoryThe desired state of the slot connection to the switch. When a slot is isolated from the switch, the switch traffic from this slot to the switch is disabled. A…
1.3.6.1.4.1.2.6.33.1.3.1.1.3ColumnswitchOperStateread-onlymandatoryThe actual state of the slot connection to the switch. When the administrative state is set to ISOLATE, the operational state becomes ISOLATED. When the operat…
1.3.6.1.4.1.2.6.33.1.3.2TablemoduleTablenot-accessiblemandatoryThis table provides the list of ATM modules in the hub.
1.3.6.1.4.1.2.6.33.1.3.2.1RowmoduleEntrynot-accessiblemandatoryEntries of moduleTable.
1.3.6.1.4.1.2.6.33.1.3.2.1.1ColumnmoduleSlotIndexread-onlymandatoryThe slot number for this module.
1.3.6.1.4.1.2.6.33.1.3.2.1.2ColumnmoduleTyperead-onlymandatoryThe type of module attached to the ATM switch in this slot. The 'unknown' value is used when the ATM agent is unable to get information for this module (the mo…
1.3.6.1.4.1.2.6.33.1.3.2.1.3ColumnmoduleDescriptionread-onlymandatoryA textual description of this module. This description is blank when no description is available.
1.3.6.1.4.1.2.6.33.1.3.2.1.4ColumnmoduleSerialNumberread-onlymandatoryThe serial number for this module.
1.3.6.1.4.1.2.6.33.1.3.2.1.5ColumnmoduleSoftwareVersionread-onlymandatoryThe version and release number for this module firmware (microcode).
1.3.6.1.4.1.2.6.33.1.3.2.1.6ColumnmoduleHardwareVersionread-onlymandatoryThe Part Number (P/N) and Engineering Change (EC) level for this module and Plant Location.
1.3.6.1.4.1.2.6.33.1.3.2.1.7ColumnmoduleAdminStateread-writemandatoryThe administrative state of this module.
1.3.6.1.4.1.2.6.33.1.3.2.1.8ColumnmoduleOperStateread-onlymandatoryThe operational test of this module.
1.3.6.1.4.1.2.6.33.1.3.2.1.9ColumnmoduleErrorsread-onlymandatoryThe number of errors detected by this module on the traffic from the switch to this module.
1.3.6.1.4.1.2.6.33.1.3.2.1.10ColumnmoduleMaxVpcread-onlymandatoryThe maximum number of VPC supported by this module. The current number of VPC that can be used is the difference between moduleMaxVpc and moduleUsedVpc.
1.3.6.1.4.1.2.6.33.1.3.2.1.11ColumnmoduleUsedVpcread-onlymandatoryThe number of VPCs currently in use for this module. The current number of VPCs that can be used is the difference between moduleMaxVpc and moduleUsedVpc.
1.3.6.1.4.1.2.6.33.1.3.2.1.12ColumnmoduleMaxVccread-onlymandatoryThe maximum number of VCCs supported by this module. The current number of VCCs that can be used is the difference between moduleMaxVcc and moduleUsedVcc.
1.3.6.1.4.1.2.6.33.1.3.2.1.13ColumnmoduleUsedVccread-onlymandatoryThe number of VCC currently in use for this module. The current number of VCC that can be used is the difference between moduleMaxVcc and moduleUsedVcc.
1.3.6.1.4.1.2.6.33.1.3.3TableportTablenot-accessiblemandatoryThis table provides the list of ports attached to the ATM switch (ATM ports). These ports belong to ATM modules inserted in slots that are attached to the ATM …
1.3.6.1.4.1.2.6.33.1.3.3.1RowportEntrynot-accessiblemandatoryEntries of portTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM switch.
1.3.6.1.4.1.2.6.33.1.3.3.1.1ColumnportSlotIndexread-onlymandatoryThe slot number of this port's module.
1.3.6.1.4.1.2.6.33.1.3.3.1.2ColumnportIndexread-onlymandatoryThe port number for this module.
1.3.6.1.4.1.2.6.33.1.3.3.1.3ColumnportInterfaceread-onlymandatoryThe interface number of this port.
1.3.6.1.4.1.2.6.33.1.3.4TableinterfaceTablenot-accessiblemandatoryFor each ATM port, this table maps the MIB-II interface index for this port with its physical slot and port numbers.
1.3.6.1.4.1.2.6.33.1.3.4.1RowinterfaceEntrynot-accessiblemandatoryEntries of the interfaceTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the A…
1.3.6.1.4.1.2.6.33.1.3.4.1.1ColumninterfaceIndexread-onlymandatoryThe interface number of the port represented by this entry. This is the same number as the index used to represent this interface in the MIB-II interface table.
1.3.6.1.4.1.2.6.33.1.3.4.1.2ColumninterfaceSlotread-onlymandatoryThe slot number of this ATM port's module.
1.3.6.1.4.1.2.6.33.1.3.4.1.3ColumninterfacePortread-onlymandatoryThe port number of this ATM port.
1.3.6.1.4.1.2.6.33.1.3.4.1.4ColumninterfaceConnectorread-onlymandatoryWhether this port is an internal port (on the backplane) or an external connector.
1.3.6.1.4.1.2.6.33.1.3.4.1.5ColumninterfaceAdminStateread-writemandatoryThe administrative state for this port. When set to disabled, no ATM traffic can pass on this port; all connections (SVC and PVC) are cleared. When set to wrap…
1.3.6.1.4.1.2.6.33.1.3.4.1.6ColumninterfaceOperStateread-onlymandatoryThe operational state for this port: - unknown: the status of this port is unknown (this can be the result of a module in error) - disabled-nosignal: no activi…
1.3.6.1.4.1.2.6.33.1.3.4.1.7ColumninterfaceAtmAccessread-writemandatoryThe type of ATM access offered on this port: - UNI: User Network Interface - SSI: Switch-to-Switch interface - NNI: Network-to-Network interface
1.3.6.1.4.1.2.6.33.1.3.4.1.8ColumninterfaceMediaTyperead-onlymandatoryThe type of cable attached to this port.
1.3.6.1.4.1.2.6.33.1.3.4.1.9ColumninterfaceMediaSpeedread-onlymandatoryThe speed of this interface, in bits per second.
1.3.6.1.4.1.2.6.33.1.3.4.1.10ColumninterfaceMediaErrorsread-onlymandatoryThe number of physical layer errors detected on this media such as violation errors and length errors.
1.3.6.1.4.1.2.6.33.1.3.4.1.11ColumninterfaceSubSlotread-onlymandatoryWhen set to 0, this interface (and its physical connector) is directly located on the module identified by the slot number. When set to a non-zero value, this …
1.3.6.1.4.1.2.6.33.1.3.4.1.12ColumninterfaceClockingread-writemandatoryThe source of the bit clock used for data transmission. When set to external, the source is the clock received from the line.
1.3.6.1.4.1.2.6.33.1.3.4.1.13ColumninterfaceScramblingread-writemandatoryWhether data scrambling is used when transmitting on this line. Scrambling may be applied at the cell level, at the frame level or at cell and frame level.
1.3.6.1.4.1.2.6.33.1.3.4.1.14ColumninterfaceAvailableBandwidthread-onlymandatoryFor a UNI or a NNI port: the current bandwidth available for the reserved bandwidth connections on this port. For a SSI port: the current bandwidth available o…
1.3.6.1.4.1.2.6.33.1.3.4.1.15ColumninterfaceAllocatedBandwidthread-onlymandatoryFor a UNI or a NNI port: the bandwidth, in bits per second, currently used by the reserved bandwidth connections on this port. For a SSI port: the bandwidth, i…
1.3.6.1.4.1.2.6.33.1.3.5NodeswitchStats
1.3.6.1.4.1.2.6.33.1.3.5.1ScalarswitchMonitoringread-writemandatoryWhen on, the switch throughput is monitored. When off, the switch thoughput is not monitored. Note that the monitoring decreases the system overall performance…
1.3.6.1.4.1.2.6.33.1.3.5.2ScalarswitchAggregateOutCellsread-onlymandatoryThe total number of cells transmitted from the switch. Note that this value is the aggregate throughput of all the ports on several minutes.
1.3.6.1.4.1.2.6.33.1.3.5.3ScalarreceiveTopListread-onlymandatoryThe ifindexes of the five most receiving interfaces. The first ifindex given is the one corresponding to the interface which has received the more cells during…
1.3.6.1.4.1.2.6.33.1.3.5.4ScalartransmitTopListread-onlymandatoryThe ifindexes of the five most transmitting interfaces. The first ifindex given is the one corresponding to the interface which has sent the more cells during …
1.3.6.1.4.1.2.6.33.1.4Nodeconnections
1.3.6.1.4.1.2.6.33.1.4NodepvcFailureA PVC failure trap is sent when a PVC becomes inoperational.
1.3.6.1.4.1.2.6.33.1.4.1TablevcXConnectTablenot-accessiblemandatoryThis table contains the cross-connections set-up in the switch for all existing VCL-based PVCs and SVCs.
1.3.6.1.4.1.2.6.33.1.4.1.1RowvcXConnectEntrynot-accessiblemandatoryEntries of vcXConnectTable.
1.3.6.1.4.1.2.6.33.1.4.1.1.1ColumnvcXInIndexread-onlymandatoryThe interface number for this ATM port.
1.3.6.1.4.1.2.6.33.1.4.1.1.2ColumnvcXInVpiread-onlymandatoryThe VPI value for this connection.
1.3.6.1.4.1.2.6.33.1.4.1.1.3ColumnvcXInVciread-onlymandatoryThe VCI value for this connection.
1.3.6.1.4.1.2.6.33.1.4.1.1.4ColumnvcXOutIndexread-onlymandatoryThe interface number for this ATM port.
1.3.6.1.4.1.2.6.33.1.4.1.1.5ColumnvcXOutVpiread-onlymandatoryThe VPI value for this connection.
1.3.6.1.4.1.2.6.33.1.4.1.1.6ColumnvcXOutVciread-onlymandatoryThe VCI value for this connection.
1.3.6.1.4.1.2.6.33.1.4.1.1.7ColumnvcXTyperead-onlymandatoryWhether this cross-connection is part of a unicast or a multicast connection.
1.3.6.1.4.1.2.6.33.1.4.1.1.8ColumnvcXDirectionread-onlymandatoryWhether this entry identifies this cross-connection in the upstream or downstream flow, as seen from the root. Downstream means that the connection was set up …
1.3.6.1.4.1.2.6.33.1.4.2TablevpXConnectTablenot-accessiblemandatoryThis table contains the cross-connections set-up in the switch for all existing VPL-based PVCs and SVCs.
1.3.6.1.4.1.2.6.33.1.4.2.1RowvpXConnectEntrynot-accessiblemandatoryEntries of vpXConnectTable.
1.3.6.1.4.1.2.6.33.1.4.2.1.1ColumnvpXInIndexread-onlymandatoryThe interface number for this ATM port.
1.3.6.1.4.1.2.6.33.1.4.2.1.2ColumnvpXInVpiread-onlymandatoryThe VPI value for this connection.
1.3.6.1.4.1.2.6.33.1.4.2.1.3ColumnvpXOutIndexread-onlymandatoryThe interface number for this ATM port.
1.3.6.1.4.1.2.6.33.1.4.2.1.4ColumnvpXOutVpiread-onlymandatoryThe VPI value for this connection.
1.3.6.1.4.1.2.6.33.1.4.2.1.5ColumnvpXTyperead-onlymandatoryWhether this cross-connection is part of a unicast or a multicast connection.
1.3.6.1.4.1.2.6.33.1.4.2.1.6ColumnvpXDirectionread-onlymandatoryWhether this entry identifies this cross-connection in the upstream or downstream flow, as seen from the root. Downstream means that the connection was set up …
1.3.6.1.4.1.2.6.33.1.5Nodeneighbor
1.3.6.1.4.1.2.6.33.1.5.1TablenbrTablenot-accessiblemandatoryThis table contains basic characteristics on adjacent ATM devices attached to this switch.
1.3.6.1.4.1.2.6.33.1.5.1.1RownbrEntrynot-accessiblemandatoryEntries of neighborTable. Each entry corresponds to a port that belongs to an ATM module. This module must be inserted in a slot that is attached to the ATM sw…
1.3.6.1.4.1.2.6.33.1.5.1.1.1ColumnlocalIndexread-onlymandatoryThe interface number for the port represented by this entry.
1.3.6.1.4.1.2.6.33.1.5.1.1.2ColumnnbrIpAddress1read-onlymandatoryOne of the IP addresses of the ATM SNMP agent of the node attached to the port/slot defined by this entry. When not available, 0.0.0.0 is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.3ColumnnbrIpAddress2read-onlymandatoryOne of the IP addresses of the ATM SNMP agent of the node attached to the port/slot defined by this entry. When not available, 0.0.0.0 is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.4ColumnnbrAtmAddressread-onlymandatoryThe ATM identification of the node attached to the port/slot defined by this entry. When not available, a null string is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.5ColumnnbrIndexread-onlymandatoryThe interface number of the adjacent node to which the connection defined by this entry is attending. When not available, 0 is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.6ColumnnbrDescriptorread-onlymandatoryThe value of the MIB-II sysDescr as reported by the device attached to this port. When not available, a null string is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.7ColumnnbrOidread-onlymandatoryThe value of the MIB-II sysOID as reported by the device attached to this port. When not available, a null string is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.8ColumnnbrNameread-onlymandatoryThe value of the MIB-II sysName as reported by the device attached to this port. When not available, a null string is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.9ColumnnbrLocationread-onlymandatoryThe value of the MIB-II sysLocation as reported by the device attached to this port. When not available, a null string is returned.
1.3.6.1.4.1.2.6.33.1.5.1.1.10ColumntrunkIdread-onlymandatoryThe internal identifier for this trunk. Set to 0 if not a trunk.
1.3.6.1.4.1.2.6.33.1.6NodecallLoggingOverflowA callLoggingOverflow trap is sent when the call logging table is about to wrap.
1.3.6.1.4.1.2.6.33.1.6Nodetftp
1.3.6.1.4.1.2.6.33.1.6.1ScalartransferControlread-writemandatoryA file transfer is initiated through a start command.
1.3.6.1.4.1.2.6.33.1.6.2ScalartransferDateread-onlymandatoryThe date and time of the last transfer.
1.3.6.1.4.1.2.6.33.1.6.3ScalarserverIpAddressread-writemandatoryThe IP address of the server used for file transfer.
1.3.6.1.4.1.2.6.33.1.6.4ScalarfileNameread-writemandatoryThe name of the file to transfer.
1.3.6.1.4.1.2.6.33.1.6.5ScalarfileTyperead-writemandatoryThe type of file to transfer. Boot and operational codes can only be dowlnoaded. Logs, traces and dumps can only be uploaded.
1.3.6.1.4.1.2.6.33.1.6.6ScalarfileTargetread-writemandatoryThe module target to which the transfer applies. When set to 0, the transfer applies to the agent itself.
1.3.6.1.4.1.2.6.33.1.6.7ScalartransferResultread-onlymandatoryThe result of the latest file transfer. When one of the TFTP variables is modified, this variable is reset to not-initialized.
1.3.6.1.4.1.2.6.33.1.7NodemoduleInstalledAn ATM module has been detected in the hub.
1.3.6.1.4.1.2.6.33.1.7Nodeservice
1.3.6.1.4.1.2.6.33.1.7.1Nodetraces
1.3.6.1.4.1.2.6.33.1.7.1.1ScalarsysTraceread-writemandatoryWhen on, the hub general trace facility is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the general trace fa…
1.3.6.1.4.1.2.6.33.1.7.1.2ScalartrsTraceread-writemandatoryWhen on, the Topology and Routing Selection trace is started. Messages are stored in the hub in a file that can be retrieved through TFTP. When off, the contro…
1.3.6.1.4.1.2.6.33.1.7.2Nodedumps
1.3.6.1.4.1.2.6.33.1.7.2.2ScalartrsDumpread-writemandatoryWhen start is selected, a dump of the Topology and Route Services component is taken. The dump is stored in the hub in a file that can be retrieved through TFT…
1.3.6.1.4.1.2.6.33.1.7.3Nodeswap
1.3.6.1.4.1.2.6.33.1.7.3.1ScalarswapControlread-writemandatoryWhen swap is selected, the backup microcode image is checked and, if valid, activated. The previously active microcode image becomes the backup image. The atm …
1.3.6.1.4.1.2.6.33.1.7.3.2ScalarswapResultread-onlymandatoryThe result of the latest microcode swap. When an operational code image is downloaded or when the system is reset, swapControl becomes not-initialized.
1.3.6.1.4.1.2.6.33.1.8NodemoduleRemovedAn ATM module is no longer detected in the hub.
1.3.6.1.4.1.2.6.33.1.9NodeatmSvc
1.3.6.1.4.1.2.6.33.1.9.1NodeatmQ2931
1.3.6.1.4.1.2.6.33.1.9.1.1TableatmQ2931ConfTablenot-accessiblemandatoryThis table contains basic information on the Q2931 protocol for each signalling link defined per port. Usually, there is only one signalling channel per interf…
1.3.6.1.4.1.2.6.33.1.9.1.1.1RowatmQ2931ConfEntrynot-accessiblemandatoryEntries of atmQ2931ConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface…
1.3.6.1.4.1.2.6.33.1.9.1.1.1.1ColumnatmQ2931ConfIndexread-onlymandatoryThe ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.2ColumnatmQ2931SiVpiread-onlymandatoryThe Vpi value which, with the Vci value specified in atmQ2931SiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per…
1.3.6.1.4.1.2.6.33.1.9.1.1.1.3ColumnatmQ2931SiVciread-onlymandatoryThe Vci value which, with the Vpi value specified in atmQ2931SiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per…
1.3.6.1.4.1.2.6.33.1.9.1.1.1.4ColumnatmQ2931T303read-onlymandatoryT303 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.5ColumnatmQ2931T308read-onlymandatoryT308 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.6ColumnatmQ2931T309read-onlymandatoryT309 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.7ColumnatmQ2931T310read-onlymandatoryT310 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.8ColumnatmQ2931T316read-onlymandatoryT316 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.9ColumnatmQ2931T317read-onlymandatoryT317 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.10ColumnatmQ2931T322read-onlymandatoryT322 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.11ColumnatmQ2931T398read-onlymandatoryT398 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.12ColumnatmQ2931T399read-onlymandatoryT399 timer as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.13ColumnatmQ2931SetupRetryread-onlymandatoryNumber of set-up retries as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.14ColumnatmQ2931ReleaseRetryread-onlymandatoryNumber of release retries as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.15ColumnatmQ2931RestartRetryread-onlymandatoryNumber of restart retries as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.1.1.16ColumnatmQ2931StatusRetryread-onlymandatoryNumber of status retries as defined in the ATM UNI Specification.
1.3.6.1.4.1.2.6.33.1.9.1.2TableatmQ2931StatsTablenot-accessiblemandatoryThis table contains statistics for the Q2931 protocol.
1.3.6.1.4.1.2.6.33.1.9.1.2.1RowatmQ2931StatsEntrynot-accessiblemandatoryEntries of atmQ2931ConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface…
1.3.6.1.4.1.2.6.33.1.9.1.2.1.1ColumnatmQ2931StatsIndexread-onlymandatoryThe ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
1.3.6.1.4.1.2.6.33.1.9.1.2.1.2ColumnatmQ2931StatsVpiread-onlymandatoryThe Vpi value which, with the Vci value specified in atmQ2931StatsVci, defines the signalling channel for this entry. Usually, there is one signalling channel …
1.3.6.1.4.1.2.6.33.1.9.1.2.1.3ColumnatmQ2931StatsVciread-onlymandatoryThe Vci value which, with the Vpi value specified in atmQ2931StatsVpi, defines the signalling channel for this entry. Usually, there is one signalling channel …
1.3.6.1.4.1.2.6.33.1.9.1.2.1.4ColumnatmQ2931OutCallAttemptsread-onlymandatoryThis is the number of outgoing call attempts on this interface, including accepted as well as rejected calls.
1.3.6.1.4.1.2.6.33.1.9.1.2.1.5ColumnatmQ2931OutCallInProgessread-onlymandatoryThis is the current number of outgoing calls in progress on this interface.
1.3.6.1.4.1.2.6.33.1.9.1.2.1.6ColumnatmQ2931OutCallFailuresread-onlymandatoryThis is the number of outgoing calls that were cleared for a reason other than a DTE or operator initiated action.
1.3.6.1.4.1.2.6.33.1.9.1.2.1.7ColumnatmQ2931InCallAttemptsread-onlymandatoryThis is the number of incoming call attempts on this interface, including accepted as well as rejected calls.
1.3.6.1.4.1.2.6.33.1.9.1.2.1.8ColumnatmQ2931InCallInProgressread-onlymandatoryThis is the current number of incoming calls in progress on this interface.
1.3.6.1.4.1.2.6.33.1.9.1.2.1.9ColumnatmQ2931InCallFailuresread-onlymandatoryThis is the number of calls that were rejected by the receiver.
1.3.6.1.4.1.2.6.33.1.9.1.3TableatmSvcTablenot-accessiblemandatoryThis table contains basic information for each active Switched Virtual Connection (SVC).
1.3.6.1.4.1.2.6.33.1.9.1.3.1RowatmSvcEntrynot-accessiblemandatoryEntries of atmSvcTable. Each entry uniquely defines two end-points of an SVC. In the case of a multicast SVC, each entry is defined by the association of the r…
1.3.6.1.4.1.2.6.33.1.9.1.3.1.1ColumnatmSvcInterfaceIndexread-onlymandatoryThe ifIndex value of the ATM interface used by this SVC.
1.3.6.1.4.1.2.6.33.1.9.1.3.1.2ColumnatmSvcSiVpiread-onlymandatoryThe Vpi value which, with the Vci value specified in atmQ2931SiVci, defines the signalling channel for this entry. Usually, there is one signalling channel per…
1.3.6.1.4.1.2.6.33.1.9.1.3.1.3ColumnatmSvcSiVciread-onlymandatoryThe Vci value which, with the Vpi value specified in atmQ2931SiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel per…
1.3.6.1.4.1.2.6.33.1.9.1.3.1.4ColumnatmSvcCallReferenceread-onlymandatoryThe Q2931 call reference value used for this SVC.
1.3.6.1.4.1.2.6.33.1.9.1.3.1.5ColumnatmSvcEndPointReferenceread-onlymandatoryOne of the Q2931 end point reference values used by this SVC. In a unicast SVC, there is only one entry for this SVC in the table. In a multicast SVC, there is…
1.3.6.1.4.1.2.6.33.1.9.1.3.1.6ColumnatmSvcCallingNumberread-onlymandatoryThe calling number carried in the calling party number information element of the call set-up message.
1.3.6.1.4.1.2.6.33.1.9.1.3.1.7ColumnatmSvcCalledNumberread-onlymandatoryThe called number carried in the called party number information element of the call set-up message.
1.3.6.1.4.1.2.6.33.1.9.1.3.1.8ColumnatmSvcClearread-writemandatoryThis variable allows a network manager to clear this SVC. When this SVC is cleared (either by the manager using this variable or by one of the parties), the en…
1.3.6.1.4.1.2.6.33.1.9.1.3.1.9ColumnatmSvcCreationTimeread-onlymandatoryThe date and time this call was placed.
1.3.6.1.4.1.2.6.33.1.9.1.3.1.10ColumnatmSvcVpiread-onlymandatoryThe VPI value used by this SVC for this interface.
1.3.6.1.4.1.2.6.33.1.9.1.3.1.11ColumnatmSvcVciread-onlymandatoryThe VCI value used by this SVC for this interface.
1.3.6.1.4.1.2.6.33.1.9.1.4ScalaratmSvcLogSizeread-onlymandatoryThe maximum number of entries supported by this local SNMP agent. When this value is exceeded, the entries are wrapped.
1.3.6.1.4.1.2.6.33.1.9.1.5ScalaratmSvcLogLevelread-writemandatoryThe maximum number of entries that can be written in the atmSvcLogTable before a trap is generated. When this number is reached, an svcLogOverflow trap is gene…
1.3.6.1.4.1.2.6.33.1.9.1.6TableatmSvcLogTablenot-accessiblemandatoryThis table contains a list of the latest Switched Virtual Connection (SVC) that were completed on this ATM node. An SVC is completed when it has been torn down…
1.3.6.1.4.1.2.6.33.1.9.1.6.1RowatmSvcLogEntrynot-accessiblemandatoryEntries of atmSvcLogTable.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.1ColumnatmSvcLogIndexread-onlymandatoryAn identification value for this entry, assigned by the local SNMP agent. This value is assigned for each new SVC call or add-party request. This index is allo…
1.3.6.1.4.1.2.6.33.1.9.1.6.1.2ColumnatmSvcLogInterfaceIndexread-onlymandatoryThe ifIndex value of the ATM interface used by this SVC.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.3ColumnatmSvcLogCallingNumberread-onlymandatoryThe calling number carried in the calling party number information element of the call set-up message.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.4ColumnatmSvcLogCalledNumberread-onlymandatoryThe called number carried in the called party number information element of the call set-up message.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.5ColumnatmSvcLogCreationTimeread-onlymandatoryThe date and time this call was placed.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.6ColumnatmSvcLogTimeread-onlymandatoryThe date and time this call was cleared.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.7ColumnatmSvcLogClearCauseread-onlymandatoryThe cause of the clearing of this SVC.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.8ColumnatmSvcLogForwardQOSread-onlymandatoryThe forward Quality Of Service requested for this call.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.9ColumnatmSvcLogBackwardQOSread-onlymandatoryThe backward Quality Of Service requested for this call.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.10ColumnatmSvcLogForwardBWread-onlymandatoryThe forward bandwidth requested for this call.
1.3.6.1.4.1.2.6.33.1.9.1.6.1.11ColumnatmSvcLogBackwardBWread-onlymandatoryThe backward bandwidth requested for this call.
1.3.6.1.4.1.2.6.33.1.9.2NodeatmSaal
1.3.6.1.4.1.2.6.33.1.9.2.1TableatmSaalConfTablenot-accessiblemandatoryThis table contains basic information on the SAAL protocol for each signalling link defined per port. Usually, there is only one signalling channel per interfa…
1.3.6.1.4.1.2.6.33.1.9.2.1.1RowatmSaalConfEntrynot-accessiblemandatoryEntries of atmSaalConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface …
1.3.6.1.4.1.2.6.33.1.9.2.1.1.1ColumnatmSaalConfIndexread-onlymandatoryThe ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
1.3.6.1.4.1.2.6.33.1.9.2.1.1.2ColumnatmSaalConfSiVpiread-onlymandatoryThe Vpi value which, with the Vci value specified in atmSaalConfSiVci, defines the signalling channel for this entry. Usually, there is one signalling channel …
1.3.6.1.4.1.2.6.33.1.9.2.1.1.3ColumnatmSaalConfSiVciread-onlymandatoryThe Vci value which, with the Vpi value specified in atmSaalConfSiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel …
1.3.6.1.4.1.2.6.33.1.9.2.1.1.4ColumnatmSaalStateread-onlymandatoryThe state of the SAAL for this interface as defined in the Q.2110 Specification, Chapter 7.3.
1.3.6.1.4.1.2.6.33.1.9.2.1.1.5ColumnatmSaalTimerPollread-onlymandatoryTimer_POLL as defined in the Q.2110 Specification. This timer is running in the active phase to assure that the peer receiver is polled often enough to return …
1.3.6.1.4.1.2.6.33.1.9.2.1.1.6ColumnatmSaalTimerKeepAliveread-onlymandatoryTimer_KEEP-ALIVE as defined in the Q.2110 Specification. This timer is started when entering the transient phase.
1.3.6.1.4.1.2.6.33.1.9.2.1.1.7ColumnatmSaalTimerNoResponseread-onlymandatoryTimer_NO-RESPONSE as defined in the Q.2110 Specification. This timer indicates the maximum time interval during which at least one STAT PDU needs to be receive…
1.3.6.1.4.1.2.6.33.1.9.2.1.1.8ColumnatmSaalTimerCCread-onlymandatoryTimer_CC as defined in the Q.2110 Specification. Transmission of PDUs is protected by this timer during establishment and release of a connection and during re…
1.3.6.1.4.1.2.6.33.1.9.2.1.1.9ColumnatmSaalTimerIdleread-onlymandatoryTimer_IDLE as defined in the Q.2110 Specification. This timer is started upon receipt of a STAT PDU when entering the idle phase (no POLL PDUs sent).
1.3.6.1.4.1.2.6.33.1.9.2.1.1.10ColumnatmSaalMaxCCread-onlymandatoryMaxCC as defined in the Q.2110 Specification. This is the maximum value for the state variable VT(CC), corresponding to the maximum number of transmissions of …
1.3.6.1.4.1.2.6.33.1.9.2.1.1.11ColumnatmSaalMaxPDread-onlymandatoryMaxPD as defined in the Q.2110 Specification. This is the maximum iacceptable value for the state variable VT(PD) before sending a POLL PDU and resetting VT(PD…
1.3.6.1.4.1.2.6.33.1.9.2.1.1.12ColumnatmSaalMaxStatread-onlymandatoryMaxSTAT as defined in the Q.2110 Specification. This is the maximum number of list elements placed in a STAT PDU.
1.3.6.1.4.1.2.6.33.1.9.2.2TableatmSaalStatsTablenot-accessiblemandatoryThis table contains statistics for the SAAL protocol, for outgoing calls only.
1.3.6.1.4.1.2.6.33.1.9.2.2.1RowatmSaalStatsEntrynot-accessiblemandatoryEntries of atmSaalConfTable. Each entry corresponds to a pair of ATM interface, signalling channel. A signalling channel is uniquely defined on each interface …
1.3.6.1.4.1.2.6.33.1.9.2.2.1.1ColumnatmSaalStatsIndexread-onlymandatoryThe ifIndex value of the ATM interface which, with the signalling channel defined by its Vpi/Vci values, uniquely identifies this entry.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.2ColumnatmSaalStatsSiVpiread-onlymandatoryThe Vpi value which, with the Vci value specified in atmSaalStatsSiVci, defines the signalling channel for this entry. Usually, there is one signalling channel…
1.3.6.1.4.1.2.6.33.1.9.2.2.1.3ColumnatmSaalStatsSiVciread-onlymandatoryThe Vci value which, with the Vpi value specified in atmSaalStatsSiVpi, defines the signalling channel for this entry. Usually, there is one signalling channel…
1.3.6.1.4.1.2.6.33.1.9.2.2.1.4ColumnatmSaalUnexpectPdusread-onlymandatoryError conditions A to M, as defined in the Q.2110 Specification. This is the number of received unsolicited or or inappropriate PDUs.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.5ColumnatmSaalUnsuccessPdusread-onlymandatoryError condition O as defined in the Q.2110 Specification. This is the number of failing retries.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.6ColumnatmSaalFailedEstablishmentread-onlymandatoryError condition P as defined in the Q.2110 Specification. This is the number of failing polls.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.7ColumnatmSaalSequenceGapread-onlymandatoryThe number of times sequence gaps were detected by the peer entity.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.8ColumnatmSaalGapNumbersread-onlymandatoryThe number of times frames were re-transmitted due to sequence gaps detected by the peer entity.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.9ColumnatmSaalOtherListErrorsread-onlymandatoryError conditions Q to V as defined in the Q.2110 Specification.
1.3.6.1.4.1.2.6.33.1.9.2.2.1.10ColumnatmSaalLackOfCreditread-onlymandatoryError condition W as defined in the Q.2110 Specification. This is the number of times that transmission was not permitted by the peer entity due to a lack of c…
1.3.6.1.4.1.2.6.33.1.9.2.2.1.11ColumnatmSaalCreditObtainedread-onlymandatoryError condition X as defined in the Q.2110 Specification. This is the number of times that credit was obtained from the peer entity to allow transmission.
1.3.6.1.4.1.2.6.33.1.10NodeatmPvc
1.3.6.1.4.1.2.6.33.1.10.1ScalaratmPvcHandlerread-onlymandatoryThe status of the PVC handler in the switch. When no more memory is available, the creation of new PVCs is rejected with a generic Error sense code.
1.3.6.1.4.1.2.6.33.1.10.2TableatmPvcTablenot-accessiblemandatoryThis table lists all PVCs defined per interface. There is only one entry in this table per PVC (point-to-point or point-to-multipoint PVC).
1.3.6.1.4.1.2.6.33.1.10.2.1RowatmPvcEntrynot-accessiblemandatoryEntries of atmPvcTable. Policing parameters are those requested when creating the PVC. The actual values used by the network to satisfy these requirements may …
1.3.6.1.4.1.2.6.33.1.10.2.1.1ColumnatmPvcIndexread-onlymandatoryThe ifIndex value of the ATM interface used by this PVC.
1.3.6.1.4.1.2.6.33.1.10.2.1.2ColumnatmPvcIdentifierread-onlymandatoryA value used to uniquely identify this PVC on this interface. To create a new PVC on a given interface, an unused PVC identifier must be found.
1.3.6.1.4.1.2.6.33.1.10.2.1.3ColumnatmPvcRowStatusread-writemandatoryStates values: active: the PVC is operational notInService: the PVC is failing notReady: values are missing to be able to activate this PVC Actions: active: th…
1.3.6.1.4.1.2.6.33.1.10.2.1.4ColumnatmPvcTyperead-writemandatoryA unicast PVC is defined between two endpoints, using either a VP or a VC connection.
1.3.6.1.4.1.2.6.33.1.10.2.1.5ColumnatmPvcEndPointread-onlymandatoryThe end-point where the PVC is created is identified as the primary or root end-point. the other end-point is the identified as the secondary or leaf end-point.
1.3.6.1.4.1.2.6.33.1.10.2.1.6ColumnatmPvcVpiread-writemandatoryThe VPI value assigned to this PVC at the origin. A value of 65536 means that no value has been specified by the operator. If no value has been specified, the …
1.3.6.1.4.1.2.6.33.1.10.2.1.7ColumnatmPvcVciread-writemandatoryThe VCI value assigned to this PVC at the origin. For VP-type PVC, this value is not applicable and is set to 0. A value of 65536 means that no value has been …
1.3.6.1.4.1.2.6.33.1.10.2.1.8ColumnatmPvcBackwardQosread-writemandatoryThe QOS requested for this PVC to the originator.
1.3.6.1.4.1.2.6.33.1.10.2.1.9ColumnatmPvcForwardQosread-writemandatoryThe QOS requested for this PVC from the originator.
1.3.6.1.4.1.2.6.33.1.10.2.1.10ColumnatmPvcBackwardTyperead-writemandatoryThe first parameter used to define the policy requested for this PVC.
1.3.6.1.4.1.2.6.33.1.10.2.1.11ColumnatmPvcForwardTyperead-writemandatoryThe type of policy requested for this PVC.
1.3.6.1.4.1.2.6.33.1.10.2.1.12ColumnatmPvcBackwardParm1read-writemandatoryThe fourth parameter used to define the policy requested for this PVC.
1.3.6.1.4.1.2.6.33.1.10.2.1.13ColumnatmPvcForwardParm1read-writemandatoryThe third parameter used to define the policy requested for this PVC.
1.3.6.1.4.1.2.6.33.1.10.3TableatmPvcEpTablenot-accessiblemandatoryThis table lists the characteristics of the remote end-points of defined PVCs. There is one entry for each PVC defined in the atmPvcTable.
1.3.6.1.4.1.2.6.33.1.10.3.1RowatmPvcEpEntrynot-accessiblemandatoryEntries of atmPvcEpTable. One entry is automatically created by the agent when a PVC is created in the PVC Table. No additional entry can be created in this ta…
1.3.6.1.4.1.2.6.33.1.10.3.1.1ColumnatmPvcEpIndexread-onlymandatoryThe ifIndex value of the ATM interface used by this PVC.
1.3.6.1.4.1.2.6.33.1.10.3.1.2ColumnatmPvcEpIdentifierread-onlymandatoryA value used to uniquely identify this PVC on this interface. This is the same identifier as the one used in the atmPvcTable to identify the PVC that this end-…
1.3.6.1.4.1.2.6.33.1.10.3.1.3ColumnatmPvcEpPartyread-onlymandatoryA value used to uniquely identify a remote end-point of a PVC, when associated with an interface index and a PVC identifier. For a point-to-point PVC, this val…
1.3.6.1.4.1.2.6.33.1.10.3.1.4ColumnatmPvcEpRowStatusread-writemandatoryStates values: active: the PVC is operational notInService: the PVC is failing notReady: values are missing to be able to activate this PVC Actions: active: th…
1.3.6.1.4.1.2.6.33.1.10.3.1.5ColumnatmPvcEpStatusCauseread-onlymandatoryA detailed cause for the current PVC status.
1.3.6.1.4.1.2.6.33.1.10.3.1.6ColumnatmPvcEpRemAddressread-writemandatoryThe ATM address of the remote ATM switch where the PVC ends. If none is specified, the ATM address of the target switch (local) is used and the PVC is confined…
1.3.6.1.4.1.2.6.33.1.10.3.1.7ColumnatmPvcEpRemIndexread-writemandatoryThe ifindex value used at the remote end to identify the interface where the PVC ends. This entry will remain in the notReady state until this attribute is set…
1.3.6.1.4.1.2.6.33.1.10.3.1.8ColumnatmPvcEpRemVpiread-writemandatoryThe VPI value assigned to this PVC at the destination (remote end). If left at 65536 (default value), one value is automatically allocated by the agent.
1.3.6.1.4.1.2.6.33.1.10.3.1.9ColumnatmPvcEpRemVciread-writemandatoryThe VCI value assigned to this PVC at the destination. For VP-type PVC, this value is not applicable and is set to 0. If left at 65536 (default value), one val…
1.3.6.1.4.1.2.6.33.1.10.3.1.10ColumnatmPvcEpLastActiveread-onlymandatoryThe date and time of the latest PVC activation.
1.3.6.1.4.1.2.6.33.1.10.3.1.11ColumnatmPvcEpQ2931Causeread-onlymandatoryThe cause of the failure as defined by Q2931.
1.3.6.1.4.1.2.6.33.1.10.3.1.12ColumnatmPvcEpFailuresread-onlymandatoryThe number of times this PVC failed.
1.3.6.1.4.1.2.6.33.2Nodeagents
1.3.6.1.4.1.2.6.33.2.1Nodeibm8260
1.3.6.1.4.1.2.6.33.2.2Nodegatwick
1.3.6.1.4.1.2.6.33.3Nodeadmin
1.3.6.1.4.1.2.6.33.3.1NodetestType
1.3.6.1.4.1.2.6.33.3.1.1NodeinternalLoopback
1.3.6.1.4.1.2.6.33.3.1.2NodeexternalLoopback
Type Definitions
NameSyntaxStatusDescription
AtmAddressOCTET STRING (SIZE(0..20))
DateAndTimeOCTET STRING (SIZE(8))
IfIndexINTEGER (0..65535)
NetPrefixOCTET STRING (SIZE(0..13))
RowStatusINTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) }