MIB Viewer

BKTEL-HFC862-HMSNE-MIB

54 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.7501.1.1.1NodeneCommon
1.3.6.1.4.1.7501.1.1.1NodeneSynchronizeEventThe SNMP trap that is generated when data on LMT must get actualized.
1.3.6.1.4.1.7501.1.1.1.1ScalarneTyperead-onlymandatoryType of NE
1.3.6.1.4.1.7501.1.1.1.2ScalarneDescriptionread-onlymandatoryThe description of the NE.
1.3.6.1.4.1.7501.1.1.1.3ScalarneLocationStreetread-writemandatoryLocation Street of Network Element. Writable size depends on net element controller, default 32
1.3.6.1.4.1.7501.1.1.1.4ScalarneLocationCityread-writemandatoryLocation City of Network Element. Writable size depends on net element controller, default 32
1.3.6.1.4.1.7501.1.1.1.5ScalarneObsolete_UsingAPSread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.6ScalarneObsolete_APSModeread-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.8ScalarneObsolete_CommonSubrackWidthread-onlyobsoleteThis parameter is obsolete. (The width of the Subracks)
1.3.6.1.4.1.7501.1.1.1.9ScalarneObsolete_CommonSubrackNumberread-onlyobsoleteThis parameter is obsolete. (The number of Subracks)
1.3.6.1.4.1.7501.1.1.1.10ScalarneObsolete_NumberModulread-onlyobsoleteThis parameter is obsolete. (Current number of entries in the Modul table)
1.3.6.1.4.1.7501.1.1.1.11ScalarneObsolete_UsingRevertiveModeread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.12ScalarneObsolete_RevertiveModeread-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.13ScalarneObsolete_InitPhaseread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.14ScalarneObsolete_PredecessorRedundantPathread-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.15ScalarneObsolete_PredecessorNominalPathread-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.1.16TableneModuleTablenot-accessiblemandatoryTable containing information about each Module.
1.3.6.1.4.1.7501.1.1.1.16.1RowneModuleEntrynot-accessiblemandatoryList of information about each Module.
1.3.6.1.4.1.7501.1.1.1.16.1.1ColumnneModuleNESlotread-onlymandatorySlot number IMPORTANT NOTE: this is a not a physical slot within a module rack, but an assigned slot ID that uniquely identifies each module including non subr…
1.3.6.1.4.1.7501.1.1.1.16.1.2ColumnneModuleSubrackread-onlymandatorySubrack number in which the module is equiped (1 .. N). A value of 0 means: No subrack number
1.3.6.1.4.1.7501.1.1.1.16.1.3ColumnneModuleModelNameread-onlymandatoryModule model name
1.3.6.1.4.1.7501.1.1.1.16.1.4ColumnneModuleMibLinkread-onlymandatoryDefines the link to the OID of the equiped module
1.3.6.1.4.1.7501.1.1.1.16.1.5ColumnneModuleSubrackSlotread-onlymandatorySlot number within subrack in which the module is equiped (1 .. N). A value of 0 means: No slot number
1.3.6.1.4.1.7501.1.1.1.16.1.6ColumnneModuleSlotUnitsUsedread-onlymandatoryFor modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. For all other module types the number of slots within…
1.3.6.1.4.1.7501.1.1.1.16.1.7ColumnneModuleSlotRackDetectionread-onlymandatoryReports the state of modules slot and rack hardware detection.
1.3.6.1.4.1.7501.1.1.1.16.1.8ColumnneModuleHousingTyperead-onlymandatoryModule housing type
1.3.6.1.4.1.7501.1.1.1.16.1.9ColumnneModuleFirmwareVersionread-onlymandatoryModule firmware version
1.3.6.1.4.1.7501.1.1.1.16.1.10ColumnneModuleHardwareVersionread-onlymandatoryModule hardware version
1.3.6.1.4.1.7501.1.1.1.16.1.11ColumnneModuleDateOfProductionread-onlymandatoryModule date of production, possible formats: - empty string -> no data defined - YYYY -> only the year of production is defined - YYYY-MM-DD -> full date of pr…
1.3.6.1.4.1.7501.1.1.1.16.1.12ColumnneModuleSerialNumberread-onlymandatoryModule serial number
1.3.6.1.4.1.7501.1.1.1.16.1.13ColumnneModuleArticleNumberread-onlymandatoryModule article number
1.3.6.1.4.1.7501.1.1.1.16.1.14ColumnneModuleCustomerCoderead-onlymandatoryCustomer specific article code
1.3.6.1.4.1.7501.1.1.1.16.1.15ColumnneModuleAliasNameread-writemandatoryModule alias name
1.3.6.1.4.1.7501.1.1.1.16.1.16ColumnneModuleUserdataread-writemandatoryModule user data
1.3.6.1.4.1.7501.1.1.1.16.1.17ColumnneModuleResetread-writemandatoryResets the module if this parameter is written to true(1).
1.3.6.1.4.1.7501.1.1.1.16.1.18ColumnneModuleLedBlinkread-writemandatoryWriting this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variabl…
1.3.6.1.4.1.7501.1.1.2NodeneStates
1.3.6.1.4.1.7501.1.1.2.1ScalarneStatesObsolete_TrapDisableread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.2ScalarneStatesObsolete_TerminalConnectedread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.4ScalarneStatesObsolete_Isolatedread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.5ScalarneStatesObsolete_ResetModullistread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.6ScalarneStatesObsolete_Redundantread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.7ScalarneStatesObsolete_ActivateRedundantPathread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.2.8ScalarneStatesObsolete_AutoOffread-onlyobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3NodeneConfig
1.3.6.1.4.1.7501.1.1.3.1ScalarneConfigObsolete_NEtyperead-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3.2ScalarneConfigObsolete_IPaddressread-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3.3ScalarneConfigObsolete_Alarmdelayread-writeobsoleteThis parameter is obsolete.
1.3.6.1.4.1.7501.1.1.3.4ScalarneConfigDeprecated_MinTrapIntervalread-writeoptionalThis parameter is deprecated. (The minimum waiting time between two traps. Only used for HMS070 over RS232 interface)
1.3.6.1.4.1.7501.1.1.3.5ScalarneConfigDeprecated_MaxTrapLifetimeread-writeoptionalThis parameter is deprecated. (The maximum lifetime of a trap. Only used for HMS070 over RS232 interface)
1.3.6.1.4.1.7501.1.1.4NodeneControl
1.3.6.1.4.1.7501.1.1.4.1ScalarneControlTrapDisableread-writemandatoryAll traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)
1.3.6.1.4.1.7501.1.1.4.2ScalarneControlResetModullistread-writemandatoryThis command removes all disconnected (not responding) modules from the module list.
1.3.6.1.4.1.7501.1.1.4.3ScalarneControlObsolete_SetDefaultAPSread-writeobsoleteThis parameter is obsolete.