This MIB module contains objects related to the Removable Power Supply support.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.17713.24.6IdentitycnRPSMibThis MIB module contains objects related to the Removable Power Supply support.
1.3.6.1.4.1.17713.24.6.1TablecnRPSTablenot-accessiblecurrentRPS entry
1.3.6.1.4.1.17713.24.6.1.1RowcnRPSTableEntrynot-accessiblecurrentPort-specific data related to the transceivers
1.3.6.1.4.1.17713.24.6.1.1.1ColumncnRPSIndexread-onlycurrentRPS index identifier attribute
1.3.6.1.4.1.17713.24.6.1.1.2ColumncnRPSOutputVoltageread-onlycurrentRated output voltage of power supply.
1.3.6.1.4.1.17713.24.6.1.1.3ColumncnRPSMaximumCurrentread-onlycurrentMaximum output current rating of the power supply.
1.3.6.1.4.1.17713.24.6.1.1.4ColumncnRPSMaximumPowerread-onlycurrentMaximum output power rating of the power supply.
1.3.6.1.4.1.17713.24.6.1.1.5ColumncnRPSStatusread-onlycurrentStatus of power supply.
1.3.6.1.4.1.17713.24.6.1.1.6ColumncnRPSCurrentInputVoltageread-onlycurrentCurrent input voltage applied to the power supply.
1.3.6.1.4.1.17713.24.6.1.1.7ColumncnRPSCurrentInputPowerread-onlycurrentCurrent input power drawn by the power supply.
1.3.6.1.4.1.17713.24.6.1.1.8ColumncnRPSMinimumInputVoltageRatingread-onlycurrentMinimum input voltage rating of the power supply.
1.3.6.1.4.1.17713.24.6.1.1.9ColumncnRPSMaximumInputVoltageRatingread-onlycurrentMaximum input voltage rating of the power supply.
1.3.6.1.4.1.17713.24.6.1.1.10ColumncnRPSTemperatureread-onlycurrentCurrent temperature of the power supply.
1.3.6.1.4.1.17713.24.6.1.1.11ColumncnRPSFaultsread-onlycurrentFaults reported by the power supply.
1.3.6.1.4.1.17713.24.6.1.1.12ColumncnRPSTyperead-onlycurrentPower supply type.
1.3.6.1.4.1.17713.24.6.1.1.13ColumncnRPSModelread-onlycurrentPower supply model name.
1.3.6.1.4.1.17713.24.6.1.1.14ColumncnRPSSerialread-onlycurrentPower supply serial number.
1.3.6.1.4.1.17713.24.6.2NotificationcnRPSTrapMsgcurrentThis notification is sent out whenever a status change occurs on a power supply.