MIB Viewer

CAREL-aria-MIB

140 objects
This is the MIB module for the aria device.
OIDNameAccessStatusDescription
1.3.6.1.4.1.9839Nodecarel
1.3.6.1.4.1.9839.1Nodesystm
1.3.6.1.4.1.9839.1.1ScalaragentReleaseread-onlycurrentRelease of the Agent.
1.3.6.1.4.1.9839.1.2ScalaragentCoderead-onlycurrentCode of the Agent. 1=WebGate
1.3.6.1.4.1.9839.2Nodeinstruments
1.3.6.1.4.1.9839.2.0NodewebGateInfo
1.3.6.1.4.1.9839.2.0.1NodeagentParameters
1.3.6.1.4.1.9839.2.0.1.1ScalarnetSizeread-writecurrentNetwork size. It corresponds to the number of units connected to the WebGate.
1.3.6.1.4.1.9839.2.0.1.2ScalarbaudRateread-writecurrentBaudrate of the Carel network.
1.3.6.1.4.1.9839.2.0.2NodeunitTypeGroup
1.3.6.1.4.1.9839.2.0.2.1Scalarunit1-Typeread-onlycurrentType of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.3NodeunitCodeGroup
1.3.6.1.4.1.9839.2.0.3.1Scalarunit1-Coderead-onlycurrentCode of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.4NodeunitSoftwareReleaseGroup
1.3.6.1.4.1.9839.2.0.4.1Scalarunit1-SoftwareReleaseread-onlycurrentSoftware release of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.5NodeunitMinSoftwareReleaseGroup
1.3.6.1.4.1.9839.2.0.5.1Scalarunit1-MinSoftwareReleaseread-onlycurrentMinimum software release of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.6NodeunitMaxSoftwareReleaseGroup
1.3.6.1.4.1.9839.2.0.6.1Scalarunit1-MaxSoftwareReleaseread-onlycurrentMaximum software release of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.7NodeunitNoAnswerCounterGroup
1.3.6.1.4.1.9839.2.0.7.1Scalarunit1-NoAnswerCounterread-onlycurrentNo answer counter of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.8NodeunitErrorChecksumCounterGroup
1.3.6.1.4.1.9839.2.0.8.1Scalarunit1-ErrorChecksumCounterread-onlycurrentError checksum counter of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.9NodeunitTimeoutCounterGroup
1.3.6.1.4.1.9839.2.0.9.1Scalarunit1-TimeoutCounterread-onlycurrentTimeout counter of the unit having serial address 1.
1.3.6.1.4.1.9839.2.0.10NodeunitOnLineStatusGroup
1.3.6.1.4.1.9839.2.0.10.1Scalarunit1-OnLineStatusread-onlycurrentOn line status of the unit having serial address 1.
1.3.6.1.4.1.9839.2.1IdentityariaMIBThis is the MIB module for the aria device.
1.3.6.1.4.1.9839.2.1.1NodedigitalObjects
1.3.6.1.4.1.9839.2.1.1.1Scalarid1read-onlycurrentDigital input 1.
1.3.6.1.4.1.9839.2.1.1.2Scalarid2read-onlycurrentDigital input 2.
1.3.6.1.4.1.9839.2.1.1.3Scalarid3read-onlycurrentDigital input 3.
1.3.6.1.4.1.9839.2.1.1.4Scalarreset_allarmiread-writecurrentAlarm reset.
1.3.6.1.4.1.9839.2.1.1.5Scalarreset_hardwareread-writecurrentARIA terminal reboot.
1.3.6.1.4.1.9839.2.1.1.6Scalarforza_invio_parametriread-writecurrentRead all configuration parameters.
1.3.6.1.4.1.9839.2.1.1.7Scalarstato_uscite_remotoread-writecurrentUses remote output status.
1.3.6.1.4.1.9839.2.1.1.8Scalarbuzzerread-writecurrentBuzzer command.
1.3.6.1.4.1.9839.2.1.1.9Scalarallarme_remotoread-onlycurrentRemote alarm.
1.3.6.1.4.1.9839.2.1.1.10Scalarid1_remotoread-writecurrentDigital remote input 1.
1.3.6.1.4.1.9839.2.1.1.11Scalarid2_remotoread-writecurrentDigital remote input 2.
1.3.6.1.4.1.9839.2.1.1.12Scalarid3_remotoread-writecurrentDigital remote input 3.
1.3.6.1.4.1.9839.2.1.1.13Scalarstato_regolazioneread-writecurrentClock functions.
1.3.6.1.4.1.9839.2.1.1.14Scalarsbrinamento_manualeread-writecurrentManual defrost.
1.3.6.1.4.1.9839.2.1.1.15Scalarforzatura_onread-writecurrentStandby override.
1.3.6.1.4.1.9839.2.1.2NodeanalogObjects
1.3.6.1.4.1.9839.2.1.2.1Scalarsonda_b1read-onlycurrentNTC temperature probe B1.
1.3.6.1.4.1.9839.2.1.2.2Scalarsonda_b2read-onlycurrentTemperature or humidity probe B2.
1.3.6.1.4.1.9839.2.1.2.3Scalarsonda_b3read-onlycurrentRemote temperature probe B3.
1.3.6.1.4.1.9839.2.1.2.5Scalarsetpoint_valigiaread-writecurrentUnoccupied mode temperature setpoint.
1.3.6.1.4.1.9839.2.1.2.6Scalarsetpoint_poltronaread-writecurrentComfort mode temperature setpoint.
1.3.6.1.4.1.9839.2.1.2.7Scalarsetpoint_lunaread-writecurrentNight mode temperature setpoint.
1.3.6.1.4.1.9839.2.1.2.8Scalardiffheatread-writecurrentTemperature regulating band.
1.3.6.1.4.1.9839.2.1.2.21Scalarr1read-writecurrentSwimming pool temperature setpoint.
1.3.6.1.4.1.9839.2.1.2.23Scalarr8read-writecurrentRelative setpoint for heating resistors.
1.3.6.1.4.1.9839.2.1.2.25Scalarr12read-writecurrentMinimum allowable temperature setpoint.
1.3.6.1.4.1.9839.2.1.2.26Scalarr13read-writecurrentMaximum allowable temperature setpoint.
1.3.6.1.4.1.9839.2.1.2.30Scalarr9read-writecurrentHeating resistors regulating band.
1.3.6.1.4.1.9839.2.1.2.31Scalarr2read-writecurrentSwimming pool temper. regulating band.
1.3.6.1.4.1.9839.2.1.2.32Scalarr4read-writecurrentTemperature dead band.
1.3.6.1.4.1.9839.2.1.2.33Scalarc5read-onlycurrentHour counter for compressor 1.
1.3.6.1.4.1.9839.2.1.2.34Scalarc6read-onlycurrentHour counter for compressor 2.
1.3.6.1.4.1.9839.2.1.2.37Scalarf3read-onlycurrentHour counter for main fan.
1.3.6.1.4.1.9839.2.1.2.38Scalarc7read-writecurrentMaintenance compressors hour threshold.
1.3.6.1.4.1.9839.2.1.2.39Scalarf4read-writecurrentMaintenance main fan hour threshold.
1.3.6.1.4.1.9839.2.1.2.40Scalarp3read-writecurrentHigh temperature alarm threshold.
1.3.6.1.4.1.9839.2.1.2.41Scalarp4read-writecurrentLow temperature alarm threshold.
1.3.6.1.4.1.9839.2.1.2.44Scalard3read-writecurrentDefrost start temperature.
1.3.6.1.4.1.9839.2.1.2.45Scalard4read-writecurrentDefrost stop temperature.
1.3.6.1.4.1.9839.2.1.2.46Scalard11read-writecurrentForced defrost start temperature.
1.3.6.1.4.1.9839.2.1.2.51Scalarr28read-writecurrentFreecooling/heating proportional band.
1.3.6.1.4.1.9839.2.1.2.52Scalarr29read-writecurrentCompressor disable temp. hysteresis.
1.3.6.1.4.1.9839.2.1.2.53Scalarr23read-writecurrentPositive gain for setpoint compensation.
1.3.6.1.4.1.9839.2.1.2.54Scalarr24read-writecurrentNegative gain for setpoint compensation.
1.3.6.1.4.1.9839.2.1.2.55Scalarr25read-writecurrentLower setpoint compensation limit.
1.3.6.1.4.1.9839.2.1.2.56Scalarr26read-writecurrentUpper setpoint compensation limit.
1.3.6.1.4.1.9839.2.1.2.57Scalars2read-writecurrentMinimum B2 reading.
1.3.6.1.4.1.9839.2.1.2.58Scalars3read-writecurrentMaximum B2 reading.
1.3.6.1.4.1.9839.2.1.2.59Scalars4read-writecurrentB1 fixed offset.
1.3.6.1.4.1.9839.2.1.2.60Scalars5read-writecurrentB2 fixed offset.
1.3.6.1.4.1.9839.2.1.3NodeintegerObjects
1.3.6.1.4.1.9839.2.1.3.8Scalarmodalita_ventoleread-writecurrentFan status.
1.3.6.1.4.1.9839.2.1.3.21Scalars1read-writecurrentB2 probe type selection.
1.3.6.1.4.1.9839.2.1.3.22Scalars8read-writecurrentInternal/external B1 probe.
1.3.6.1.4.1.9839.2.1.3.23Scalars6read-writecurrentB1 digital filter time constant.
1.3.6.1.4.1.9839.2.1.3.24Scalars9read-writecurrentB2 digital filter time constant.
1.3.6.1.4.1.9839.2.1.3.25Scalars10read-writecurrentB3 digital filter time constant.
1.3.6.1.4.1.9839.2.1.3.26Scalarr19read-writecurrentType regulation.
1.3.6.1.4.1.9839.2.1.3.27Scalarr20read-writecurrentRegulation integral time.
1.3.6.1.4.1.9839.2.1.3.28Scalarr21read-writecurrentRegulation startup delay.
1.3.6.1.4.1.9839.2.1.3.29Scalarh3read-writecurrentDigital input ID1 operating mode.
1.3.6.1.4.1.9839.2.1.3.30Scalarh4read-writecurrentDigital input ID2 operating mode.
1.3.6.1.4.1.9839.2.1.3.31Scalarh5read-writecurrentDigital input ID3 operating mode.
1.3.6.1.4.1.9839.2.1.3.32Scalarp2read-writecurrentDigital input ID3 alarm type.
1.3.6.1.4.1.9839.2.1.3.33Scalars7read-writecurrentTemperature �C/�F unit selection.
1.3.6.1.4.1.9839.2.1.3.35Scalarh18read-writecurrentPump operating mode.
1.3.6.1.4.1.9839.2.1.3.36Scalarc1read-writecurrentMinimum compressor ON time.
1.3.6.1.4.1.9839.2.1.3.37Scalarc2read-writecurrentMinimum compressor OFF time.
1.3.6.1.4.1.9839.2.1.3.38Scalarc3read-writecurrentMinimum delay for compressor restart.
1.3.6.1.4.1.9839.2.1.3.39Scalarc4read-writecurrentMinimum delay for second comp. start.
1.3.6.1.4.1.9839.2.1.3.40Scalarc8read-writecurrentFan ON delay from heat resistor ON.
1.3.6.1.4.1.9839.2.1.3.41Scalarf1read-writecurrentFan ON supplementary delay.
1.3.6.1.4.1.9839.2.1.3.42Scalarf2read-writecurrentFan OFF supplementary delay.
1.3.6.1.4.1.9839.2.1.3.43Scalarf6read-writecurrentExternal fan OFF delay.
1.3.6.1.4.1.9839.2.1.3.46Scalarf14read-writecurrentAnti-stratification inactivity time
1.3.6.1.4.1.9839.2.1.3.47Scalarf15read-writecurrentAir stirring active duration.
1.3.6.1.4.1.9839.2.1.3.48Scalarr18read-writecurrentCompressor selection rotation enable.
1.3.6.1.4.1.9839.2.1.3.49Scalarr10read-writecurrentHeating resistors enable.
1.3.6.1.4.1.9839.2.1.3.50Scalarr11read-writecurrentHeating resistors with compressor enable.
1.3.6.1.4.1.9839.2.1.3.51Scalarf7read-writecurrentCondensation control operating mode.
1.3.6.1.4.1.9839.2.1.3.52Scalarp5read-writecurrentHigh/low temper./humidity alarm delay.
1.3.6.1.4.1.9839.2.1.3.53Scalarp9read-writecurrentID2 low pressure alarm delay (COOL).
1.3.6.1.4.1.9839.2.1.3.54Scalarp10read-writecurrentID2 low pressure alarm delay (HEAT).
1.3.6.1.4.1.9839.2.1.3.55Scalarp11read-writecurrentID2 low pressure alarm delay (defrost).
1.3.6.1.4.1.9839.2.1.3.56Scalarp6read-writecurrentID3 alarm delay.
1.3.6.1.4.1.9839.2.1.3.57Scalarh7read-writecurrentSmall LCD reading selection.
1.3.6.1.4.1.9839.2.1.3.59Scalarh13read-writecurrentClock and timetable mode selection.
1.3.6.1.4.1.9839.2.1.3.60Scalarh6read-writecurrentLocal keyboard lock.
1.3.6.1.4.1.9839.2.1.3.61Scalarh10read-writecurrentLCD contrast.
1.3.6.1.4.1.9839.2.1.3.67Scalarh1read-writecurrentMachine type selection.
1.3.6.1.4.1.9839.2.1.3.68Scalarh2read-writecurrentProgrammable output operating mode.
1.3.6.1.4.1.9839.2.1.3.70Scalarf5read-writecurrentContinuous main fan operation enable.
1.3.6.1.4.1.9839.2.1.3.71Scalard1read-writecurrentDefrost enable.
1.3.6.1.4.1.9839.2.1.3.72Scalard2read-writecurrentDefrost stop mode selection.
1.3.6.1.4.1.9839.2.1.3.73Scalard5read-writecurrentDefrost start delay.
1.3.6.1.4.1.9839.2.1.3.74Scalard6read-writecurrentDefrost maximum duration.
1.3.6.1.4.1.9839.2.1.3.75Scalard7read-writecurrentSuccessive defrost start delay.
1.3.6.1.4.1.9839.2.1.3.76Scalard8read-writecurrentDefrost with heat resistors enable.
1.3.6.1.4.1.9839.2.1.3.77Scalard9read-writecurrentCompressor pause at defrost start & stop.
1.3.6.1.4.1.9839.2.1.3.78Scalard10read-writecurrentCompr. ON delay after valve inversion.
1.3.6.1.4.1.9839.2.1.3.79Scalard12read-writecurrentd7 step change for smart defrost.
1.3.6.1.4.1.9839.2.1.3.80Scalard13read-writecurrentManual defrost request.
1.3.6.1.4.1.9839.2.1.3.83Scalarr27read-writecurrentFreecooling/heating mode selection.
1.3.6.1.4.1.9839.2.1.3.84Scalarl4read-writecurrentAir duct shutter total run time.
1.3.6.1.4.1.9839.2.1.3.85Scalarh16read-writecurrentSetpoint compensation enable.
1.3.6.1.4.1.9839.2.1.3.86Scalarp12read-writecurrentID2 low pressure alarm reset mode.
1.3.6.1.4.1.9839.2.1.3.87Scalarl1read-onlycurrentNetwork address.
1.3.6.1.4.1.9839.2.1.3.88Scalarl2read-writecurrentpLAN description address
1.3.6.1.4.1.9839.2.1.3.89Scalarl3read-writecurrentpLAN pages
1.3.6.1.4.1.9839.2.1.3.90Scalarl5read-writecurrentRemote input selection mask.
1.3.6.1.4.1.9839.2.1.3.91Scalarr14read-writecurrentAntifreeze enable.