CPI-UNITY-MIB

1069 objects
The MIB module is used to register Chatsworth eConnect related SNMP OIDs for all models. Copyright 2014-2019 Chatsworth Products, Inc. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Chatsworth Products, Inc makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter64 enterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.30932Nodecpi
1.3.6.1.4.1.30932.1IdentityproductsThe MIB module is used to register Chatsworth eConnect related SNMP OIDs for all models. Copyright 2014-2019 Chatsworth Products, Inc. All rights reserved. Rep…
1.3.6.1.4.1.30932.1.1NodecpiPDU
1.3.6.1.4.1.30932.1.1.1NodesystemInfo
1.3.6.1.4.1.30932.1.1.1.1Scalarversionread-onlycurrentSoftware Version.
1.3.6.1.4.1.30932.1.1.1.2ScalarmodelCoderead-onlycurrentModel code for the PDU.
1.3.6.1.4.1.30932.1.1.1.3ScalarhwAddressread-onlycurrentPDU hardware MAC address.
1.3.6.1.4.1.30932.1.1.2Nodeconfiguration
1.3.6.1.4.1.30932.1.1.2.1ScalarlogIntervalread-writecurrentThe time interval in seconds for logging metrics (disabled if < 10).
1.3.6.1.4.1.30932.1.1.2.1Nodenetwork
1.3.6.1.4.1.30932.1.1.2.1.1Nodeipv4
1.3.6.1.4.1.30932.1.1.2.1.2Nodeipv6
1.3.6.1.4.1.30932.1.1.2.1.2.1ScalaripV6Enableread-writecurrentControls whether the IPv6 network interface is enabled.
1.3.6.1.4.1.30932.1.1.2.1.2.6ScalarautoDNSv6read-writecurrentControls whether the DNS IPv6 address is retrieved from a DHCP server or is set statically.
1.3.6.1.4.1.30932.1.1.2.1.2.7ScalarsubnetMaskv6read-writecurrentThe subnet mask associated with the IPv6 address of this entry. The value of the mask is an IPv6 address with all the network bits set to 1 and all the hosts b…
1.3.6.1.4.1.30932.1.1.2.1.2.8Scalargatewayv6read-writecurrentSet or get the IPv6 address of the gateway router for the PDU.
1.3.6.1.4.1.30932.1.1.2.1.2.9Scalardns1v6read-writecurrentSet or get the IPv6 address of the first DNS entry for the PDU.
1.3.6.1.4.1.30932.1.1.2.1.2.10Scalardns2v6read-writecurrentSet or get the IPv6 address of the second DNS entry for the PDU.
1.3.6.1.4.1.30932.1.1.2.1.2.11Scalardns3v6read-writecurrentSet or get the IPv6 address of the third DNS entry for the PDU.
1.3.6.1.4.1.30932.1.1.2.1.3Nodetime
1.3.6.1.4.1.30932.1.1.2.2ScalaralarmIntervalread-writecurrentThe time interval in seconds for alarm cycle (disabled if < 10).
1.3.6.1.4.1.30932.1.1.2.2Nodeinterfaces
1.3.6.1.4.1.30932.1.1.2.2.1Nodesnmp
1.3.6.1.4.1.30932.1.1.2.2.1.18NodesnmpControl
1.3.6.1.4.1.30932.1.1.2.2.1.18.5ScalarenableEASSNMPControlread-writecurrentAllows the use of SNMP to open/close the door locks. It is recommended that this only be enabled with SNMP v3 configurations.
1.3.6.1.4.1.30932.1.1.2.2.2Nodehttp
1.3.6.1.4.1.30932.1.1.2.2.3Nodesmtp
1.3.6.1.4.1.30932.1.1.2.2.3.1ScalarenableSMTPread-writecurrentControls whether the mail notification service is enabled..
1.3.6.1.4.1.30932.1.1.2.3ScalarlogDifferenceread-writecurrentThe current difference in 1/100 Amps that triggers logging metrics.
1.3.6.1.4.1.30932.1.1.2.3Nodelogging
1.3.6.1.4.1.30932.1.1.2.3.1ScalarlogEnableread-writecurrentControls whether the data logging feature is enabled.
1.3.6.1.4.1.30932.1.1.2.3.23ScalarsysLogIdentityread-writecurrentGet or set the identity to use with the syslog. The identity is an arbitrary identification string which syslog will prefix to each message. This is intended t…
1.3.6.1.4.1.30932.1.1.2.3.24ScalarsysLogFacilityread-writecurrentGet or set the facility to use with the syslog. The facility argument is used to specify what type of program is logging the message.
1.3.6.1.4.1.30932.1.1.2.3.25ScalarsysLogCentralServerAddrread-writecurrentGet or set the IP address for the central syslog server.
1.3.6.1.4.1.30932.1.1.2.3.26ScalarsysLogCentralServerPortread-writecurrentGet or set the port for the central syslog server.
1.3.6.1.4.1.30932.1.1.2.4Nodeaccesscontrol
1.3.6.1.4.1.30932.1.1.2.4ScalarpduIPread-writecurrentPDU IP address.
1.3.6.1.4.1.30932.1.1.2.4.1Nodeldap
1.3.6.1.4.1.30932.1.1.2.4.1.1ScalarenableADAuthread-writecurrentControls whether the Active Directory authentication is enabled.
1.3.6.1.4.1.30932.1.1.2.4.2Noderadius
1.3.6.1.4.1.30932.1.1.2.4.2.1ScalarenableRadiusAuthread-writecurrentControls whether radius authentication is enabled.
1.3.6.1.4.1.30932.1.1.2.4.2.7Scalarradiusip6read-writecurrentEnable/Disable IPv6 for radius authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.8Scalarradiuscardenableread-writecurrentEnable/Disable Radius for card authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.9Scalarcardradiusserverread-writecurrentSet or get the IP address of the Primary Radius Card Authentication Server.
1.3.6.1.4.1.30932.1.1.2.4.2.10Scalarcardradiusshsecretread-writecurrentSet or get the Radius Card Shared Secret.
1.3.6.1.4.1.30932.1.1.2.4.2.11ScalarcardradiusPortread-writecurrentSet or get the port for Radius Card Authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.12Scalarcardradiusip6read-writecurrentEnable/Disable IPv6 for Radius Card Authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.13ScalarradiusServer2read-writecurrentSet or get the IP address of the Secondary Radius Authentication Server.
1.3.6.1.4.1.30932.1.1.2.4.2.14ScalarradiusPort2read-writecurrentSet or get the port for Secondary Radius Authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.15ScalarradiusServer3read-writecurrentSet or get the IP address of the Tertiary Radius Authentication Server.
1.3.6.1.4.1.30932.1.1.2.4.2.16ScalarradiusPort3read-writecurrentSet or get the port for Tertiary Radius Authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.17ScalarcardradiusServer2read-writecurrentSet or get the IP address of the Secondary Radius Card Authentication Server.
1.3.6.1.4.1.30932.1.1.2.4.2.18ScalarcardradiusPort2read-writecurrentSet or get the port for Secondary Radius Card Authentication.
1.3.6.1.4.1.30932.1.1.2.4.2.19ScalarcardradiusServer3read-writecurrentSet or get the IP address of the Tertiary Radius Card Authentication Server.
1.3.6.1.4.1.30932.1.1.2.4.2.20ScalarcardradiusPort3read-writecurrentSet or get the port for Tertiary Radius Card Authentication.
1.3.6.1.4.1.30932.1.1.2.5NodenetOptions
1.3.6.1.4.1.30932.1.1.2.5.1ScalarautoIPread-writecurrentSelect dynamic (Auto) or static IP, 0=static and 1=dynamic.
1.3.6.1.4.1.30932.1.1.2.5.2ScalarautoDNSread-writecurrentSelect dynamic (Auto) or static DNS, 0=static and 1=dynamic.
1.3.6.1.4.1.30932.1.1.2.5.3ScalaripV4Enableread-writecurrentEnable IPV4 Network, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.5.4ScalarsnmpEnableread-writecurrentEnable SNMP network service, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.5.5ScalartelnetEnableread-writecurrentEnable Telnet service, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.5.6ScalarsshEnableread-writecurrentEnable SSH Service, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.5.7ScalarhttpEnableread-writecurrentEnable HTTP Service, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.5.8ScalarhttpsEnableread-writecurrentEnable HTTPS Service, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.6Nodepdu
1.3.6.1.4.1.30932.1.1.2.6ScalarsubnetMaskread-writecurrentPDU Subnet Mask.
1.3.6.1.4.1.30932.1.1.2.6.9ScalarsumAmpsread-writecurrentControl whether the PDU displays the amperage sum of all branchs.
1.3.6.1.4.1.30932.1.1.2.7Nodealerts
1.3.6.1.4.1.30932.1.1.2.7Scalargatewayread-writecurrentPDU Gateway Address.
1.3.6.1.4.1.30932.1.1.2.8NodednsHosts
1.3.6.1.4.1.30932.1.1.2.8Noderouting
1.3.6.1.4.1.30932.1.1.2.8.1Scalardns1read-writecurrentPDU DNS 1 IP.
1.3.6.1.4.1.30932.1.1.2.8.1NodeeventLogRouting
1.3.6.1.4.1.30932.1.1.2.8.1.1ScalarlogBranchCritLowVoltageread-writecurrentEnable/Disable logging of Critical Low Voltage on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.2ScalarlogBranchWarnLowVoltageread-writecurrentEnable/Disable logging of Warning Low Voltage on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.3ScalarlogBranchWarnHighVoltageread-writecurrentEnable/Disable logging of Warning High Voltage on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.4ScalarlogBranchCritHighVoltageread-writecurrentEnable/Disable logging of Critical High Voltage on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.5ScalarlogBranchCritLowCurrentread-writecurrentEnable/Disable logging of Critical Low Current on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.6ScalarlogBranchWarnLowCurrentread-writecurrentEnable/Disable logging of Warning Low Current on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.7ScalarlogBranchWarnHighCurrentread-writecurrentEnable/Disable logging of Warning High Current on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.8ScalarlogBranchCritHighCurrentread-writecurrentEnable/Disable logging of Critical High Current on the Branch to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.9ScalarlogOutletCritLowCurrentread-writecurrentEnable/Disable logging of Critical Low Current on the Outlet to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.10ScalarlogOutletWarnLowCurrentread-writecurrentEnable/Disable logging of Warning Low Current on the Outlet to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.11ScalarlogOutletWarnHighCurrentread-writecurrentEnable/Disable logging of Warning High Current on the Outlet to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.12ScalarlogOutletCritHighCurrentread-writecurrentEnable/Disable logging of Critical High Current to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.13ScalarlogTempCritLowread-writecurrentEnable/Disable logging of Critical Low Temperature to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.14ScalarlogTempWarnLowread-writecurrentEnable/Disable logging of Warning Low Temperature to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.15ScalarlogTempWarnHighread-writecurrentEnable/Disable logging of Warning High Temperature to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.16ScalarlogTempCritHighread-writecurrentEnable/Disable logging of Critical High Temperature to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.17ScalarlogHumidCritLowread-writecurrentEnable/Disable logging of Critical Low Humidity to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.18ScalarlogHumidWarnLowread-writecurrentEnable/Disable logging of Warning Low Humidity to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.19ScalarlogHumidWarnHighread-writecurrentEnable/Disable logging of Warning High Humidity to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.20ScalarlogHumidCritHighread-writecurrentEnable/Disable logging of Critical High Humidity to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.21ScalarlogScanPassread-writecurrentEnable/Disable logging of successful card scan events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.22ScalarlogScanFailread-writecurrentEnable/Disable logging of failed card scan events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.23ScalarlogDoorStateread-writecurrentEnable/Disable logging of Door Open/Close events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.24ScalarlogLockStateread-writecurrentEnable/Disable logging of Lock Open/Close events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.25ScalarlogExtendedOpenread-writecurrentEnable/Disable logging of extended door open events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.26ScalarlogFirmareUpdateread-writecurrentEnable/Disable logging of Firmare Update events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.27ScalarlogConfigUpdateread-writecurrentEnable/Disable logging of configuration change events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.28ScalarlogRecepChangeread-writecurrentEnable/Disable logging of receptacle change events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.29ScalarlogSystemread-writecurrentEnable/Disable logging of system events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.30ScalarlogPduAccessread-writecurrentEnable/Disable logging of access to PDU events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.1.31ScalarlogSecureArrayread-writecurrentEnable/Disable logging of SecureArray events to the event log.
1.3.6.1.4.1.30932.1.1.2.8.2Scalardns2read-writecurrentPDU DNS 2 IP.
1.3.6.1.4.1.30932.1.1.2.8.2NodeemailRouting
1.3.6.1.4.1.30932.1.1.2.8.2.1ScalaremailBranchCritLowVoltageread-writecurrentEnable/Disable notification of Critical Low Voltage on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.2ScalaremailBranchWarnLowVoltageread-writecurrentEnable/Disable notification of Warning Low Voltage on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.3ScalaremailBranchWarnHighVoltageread-writecurrentEnable/Disable notification of Warning High Voltage on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.4ScalaremailBranchCritHighVoltageread-writecurrentEnable/Disable notification of Critical High Voltage on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.5ScalaremailBranchCritLowCurrentread-writecurrentEnable/Disable notification of Critical Low Current on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.6ScalaremailBranchWarnLowCurrentread-writecurrentEnable/Disable notification of Warning Low Current on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.7ScalaremailBranchWarnHighCurrentread-writecurrentEnable/Disable notification of Warning High Current on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.8ScalaremailBranchCritHighCurrentread-writecurrentEnable/Disable notification of Critical High Current on the Branch in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.9ScalaremailOutletCritLowCurrentread-writecurrentEnable/Disable notification of Critical Low Current on the Outlet in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.10ScalaremailOutletWarnLowCurrentread-writecurrentEnable/Disable notification of Warning Low Current on the Outlet in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.11ScalaremailOutletWarnHighCurrentread-writecurrentEnable/Disable notification of Warning High Current on the Outlet in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.12ScalaremailOutletCritHighCurrentread-writecurrentEnable/Disable notification of Critical High Current in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.13ScalaremailTempCritLowread-writecurrentEnable/Disable notification of Critical Low Temperature in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.14ScalaremailTempWarnLowread-writecurrentEnable/Disable notification of Warning Low Temperature in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.15ScalaremailTempWarnHighread-writecurrentEnable/Disable notification of Warning High Temperature in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.16ScalaremailTempCritHighread-writecurrentEnable/Disable notification of Critical High Temperature in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.17ScalaremailHumidCritLowread-writecurrentEnable/Disable notification of Critical Low Humidity in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.18ScalaremailHumidWarnLowread-writecurrentEnable/Disable notification of Warning Low Humidity in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.19ScalaremailHumidWarnHighread-writecurrentEnable/Disable notification of Warning High Humidity in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.20ScalaremailHumidCritHighread-writecurrentEnable/Disable notification of Critical High Humidity in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.21ScalaremailScanPassread-writecurrentEnable/Disable notification of successful card scan events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.22ScalaremailScanFailread-writecurrentEnable/Disable notification of failed card scan events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.23ScalaremailDoorStateread-writecurrentEnable/Disable notification of Door Open/Close events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.24ScalaremailLockStateread-writecurrentEnable/Disable notification of Lock Open/Close events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.25ScalaremailExtendedOpenread-writecurrentEnable/Disable notification of extended door open events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.26ScalaremailFirmareUpdateread-writecurrentEnable/Disable notification of Firmare Update events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.27ScalaremailConfigUpdateread-writecurrentEnable/Disable notification of configuration change events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.28ScalaremailRecepChangeread-writecurrentEnable/Disable notification of receptacle change events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.29ScalaremailSystemread-writecurrentEnable/Disable notification of system events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.30ScalaremailPduAccessread-writecurrentEnable/Disable notification of access to PDU events in an email.
1.3.6.1.4.1.30932.1.1.2.8.2.31ScalaremailSecureArrayread-writecurrentEnable/Disable notification of SecureArray events in an email.
1.3.6.1.4.1.30932.1.1.2.8.3Scalardns3read-writecurrentPDU DNS 3 IP.
1.3.6.1.4.1.30932.1.1.2.8.3NodetrapRouting
1.3.6.1.4.1.30932.1.1.2.8.3.1ScalartrapBranchCritLowVoltageread-writecurrentEnable/Disable notification of Critical Low Voltage on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.2ScalartrapBranchWarnLowVoltageread-writecurrentEnable/Disable notification of Warning Low Voltage on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.3ScalartrapBranchWarnHighVoltageread-writecurrentEnable/Disable notification of Warning High Voltage on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.4ScalartrapBranchCritHighVoltageread-writecurrentEnable/Disable notification of Critical High Voltage on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.5ScalartrapBranchCritLowCurrentread-writecurrentEnable/Disable notification of Critical Low Current on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.6ScalartrapBranchWarnLowCurrentread-writecurrentEnable/Disable notification of Warning Low Current on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.7ScalartrapBranchWarnHighCurrentread-writecurrentEnable/Disable notification of Warning High Current on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.8ScalartrapBranchCritHighCurrentread-writecurrentEnable/Disable notification of Critical High Current on the Branch in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.9ScalartrapOutletCritLowCurrentread-writecurrentEnable/Disable notification of Critical Low Current on the Outlet in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.10ScalartrapOutletWarnLowCurrentread-writecurrentEnable/Disable notification of Warning Low Current on the Outlet in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.11ScalartrapOutletWarnHighCurrentread-writecurrentEnable/Disable notification of Warning High Current on the Outlet in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.12ScalartrapOutletCritHighCurrentread-writecurrentEnable/Disable notification of Critical High Current in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.13ScalartrapTempCritLowread-writecurrentEnable/Disable notification of Critical Low Temperature in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.14ScalartrapTempWarnLowread-writecurrentEnable/Disable notification of Warning Low Temperature in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.15ScalartrapTempWarnHighread-writecurrentEnable/Disable notification of Warning High Temperature in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.16ScalartrapTempCritHighread-writecurrentEnable/Disable notification of Critical High Temperature in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.17ScalartrapHumidCritLowread-writecurrentEnable/Disable notification of Critical Low Humidity in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.18ScalartrapHumidWarnLowread-writecurrentEnable/Disable notification of Warning Low Humidity in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.19ScalartrapHumidWarnHighread-writecurrentEnable/Disable notification of Warning High Humidity in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.20ScalartrapHumidCritHighread-writecurrentEnable/Disable notification of Critical High Humidity in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.21ScalartrapScanPassread-writecurrentEnable/Disable notification of successful card ID scans in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.22ScalartrapScanFailread-writecurrentEnable/Disable notification of failed card ID scans in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.23ScalartrapDoorStateread-writecurrentEnable/Disable notification of Door Open/Closed events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.24ScalartrapLockStateread-writecurrentEnable/Disable notification of Lock Open/Closed events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.25ScalartrapExtendedOpenread-writecurrentEnable/Disable notification of extended door open events in an trap.
1.3.6.1.4.1.30932.1.1.2.8.3.26ScalartrapFirmareUpdateread-writecurrentEnable/Disable notification of Firmare Update events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.27ScalartrapConfigUpdateread-writecurrentEnable/Disable notification of configuration change events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.28ScalartrapRecepChangeread-writecurrentEnable/Disable notification of receptacle change events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.29ScalartrapSystemread-writecurrentEnable/Disable notification of system events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.30ScalartrapPduAccessread-writecurrentEnable/Disable notification of access to PDU events in a trap.
1.3.6.1.4.1.30932.1.1.2.8.3.31ScalartrapSecureArrayread-writecurrentEnable/Disable notification of SecureArray events in a trap.
1.3.6.1.4.1.30932.1.1.2.9NodesnmpHosts
1.3.6.1.4.1.30932.1.1.2.9.1ScalarsnmpHost1read-writecurrentSNMP Host 1 IP address.
1.3.6.1.4.1.30932.1.1.2.9.2ScalarsnmpHost2read-writecurrentSNMP Host 2 IP address.
1.3.6.1.4.1.30932.1.1.2.9.3ScalarsnmpHost3read-writecurrentSNMP Host 3 IP address.
1.3.6.1.4.1.30932.1.1.2.9.5ScalarsnmpHostIPv61read-writecurrentSet or get the IPv6 address of the first host the SNMP service will reply to.
1.3.6.1.4.1.30932.1.1.2.9.6ScalarsnmpHostIPv62read-writecurrentSet or get the IPv6 address of the first host the SNMP service will reply to.
1.3.6.1.4.1.30932.1.1.2.9.7ScalarsnmpHostIPV63read-writecurrentSet or get the IPv6 address of the first host the SNMP service will reply to.
1.3.6.1.4.1.30932.1.1.2.10ScalarpduIPv6read-writecurrentPDU IPV6 address.
1.3.6.1.4.1.30932.1.1.2.11NodenetOptionsIPv6
1.3.6.1.4.1.30932.1.1.2.11.1ScalarautoIPv6read-writecurrentSelect IPV6 dynamic (Auto) or static IP, 0=static and 1=dynamic.
1.3.6.1.4.1.30932.1.1.2.11.2ScalarautoDNSIPv6read-writecurrentSelect IPV6 dynamic (Auto) or static DNS, 0=static and 1=dynamic.
1.3.6.1.4.1.30932.1.1.2.11.3Scalaripv6Enableread-writecurrentEnable IPV6 Network, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.11.4ScalarlinkLocalEnableread-writecurrentEnable IPV6 Link-Local, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.11.5ScalarglobalAddrEnableread-writecurrentEnable IPV6 Global Address, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.12ScalarsubnetMaskIPv6read-writecurrentPDU IPV6 Subnet Mask.
1.3.6.1.4.1.30932.1.1.2.13ScalargatewayIPv6read-writecurrentPDU IPV6 Gateway Address.
1.3.6.1.4.1.30932.1.1.2.14NodednsHostIPv6
1.3.6.1.4.1.30932.1.1.2.14.1Scalardns1IPv6read-writecurrentPDU DNS 2 for IPV6.
1.3.6.1.4.1.30932.1.1.2.14.2Scalardns2IPv6read-writecurrentPDU DNS 3 for IPV6.
1.3.6.1.4.1.30932.1.1.2.14.3Scalardns3IPv6read-writecurrentPDU DNS 4 for IPV6.
1.3.6.1.4.1.30932.1.1.2.15NodesnmpHostsIPv6
1.3.6.1.4.1.30932.1.1.2.15.1ScalarsnmpHost1IPv6read-writecurrentSNMP Host 1 IPV6.
1.3.6.1.4.1.30932.1.1.2.15.2ScalarsnmpHost2IPv6read-writecurrentSNMP Host 2 IPV6.
1.3.6.1.4.1.30932.1.1.2.15.3ScalarsnmpHost3IPv6read-writecurrentSNMP Host 3 IPV6.
1.3.6.1.4.1.30932.1.1.2.16NodereceptacleControl
1.3.6.1.4.1.30932.1.1.2.16.1Scalaroutlet1Ctrlread-writecurrentOutlet1 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.2Scalaroutlet2Ctrlread-writecurrentOutlet2 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.3Scalaroutlet3Ctrlread-writecurrentOutlet3 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.4Scalaroutlet4Ctrlread-writecurrentOutlet4 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.5Scalaroutlet5Ctrlread-writecurrentOutlet5 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.6Scalaroutlet6Ctrlread-writecurrentOutlet6 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.7Scalaroutlet7Ctrlread-writecurrentOutlet7 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.8Scalaroutlet8Ctrlread-writecurrentOutlet8 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.9Scalaroutlet9Ctrlread-writecurrentOutlet9 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.10Scalaroutlet10Ctrlread-writecurrentOutlet10 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.11Scalaroutlet11Ctrlread-writecurrentOutlet11 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.12Scalaroutlet12Ctrlread-writecurrentOutlet12 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.13Scalaroutlet13Ctrlread-writecurrentOutlet13 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.14Scalaroutlet14Ctrlread-writecurrentOutlet14 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.15Scalaroutlet15Ctrlread-writecurrentOutlet15 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.16Scalaroutlet16Ctrlread-writecurrentOutlet16 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.17Scalaroutlet17Ctrlread-writecurrentOutlet17 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.18Scalaroutlet18Ctrlread-writecurrentOutlet18 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.19Scalaroutlet19Ctrlread-writecurrentOutlet19 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.20Scalaroutlet20Ctrlread-writecurrentOutlet20 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.21Scalaroutlet21Ctrlread-writecurrentOutlet21 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.22Scalaroutlet22Ctrlread-writecurrentOutlet22 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.23Scalaroutlet23Ctrlread-writecurrentOutlet23 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.16.24Scalaroutlet24Ctrlread-writecurrentOutlet24 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.2.17NodereceptacleONdelay
1.3.6.1.4.1.30932.1.1.2.17.1Scalaroutlet1ONdlyread-writecurrentOutlet1 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.2Scalaroutlet2ONdlyread-writecurrentOutlet2 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.3Scalaroutlet3ONdlyread-writecurrentOutlet3 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.4Scalaroutlet4ONdlyread-writecurrentOutlet4 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.5Scalaroutlet5ONdlyread-writecurrentOutlet5 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.6Scalaroutlet6ONdlyread-writecurrentOutlet6 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.7Scalaroutlet7ONdlyread-writecurrentOutlet7 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.8Scalaroutlet8ONdlyread-writecurrentOutlet8 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.9Scalaroutlet9ONdlyread-writecurrentOutlet9 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.10Scalaroutlet10ONdlyread-writecurrentOutlet10 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.11Scalaroutlet11ONdlyread-writecurrentOutlet11 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.12Scalaroutlet12ONdlyread-writecurrentOutlet12 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.13Scalaroutlet13ONdlyread-writecurrentOutlet13 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.14Scalaroutlet14ONdlyread-writecurrentOutlet14 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.15Scalaroutlet15ONdlyread-writecurrentOutlet15 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.16Scalaroutlet16ONdlyread-writecurrentOutlet16 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.17Scalaroutlet17ONdlyread-writecurrentOutlet17 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.18Scalaroutlet18ONdlyread-writecurrentOutlet18 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.19Scalaroutlet19ONdlyread-writecurrentOutlet19 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.20Scalaroutlet20ONdlyread-writecurrentOutlet20 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.21Scalaroutlet21ONdlyread-writecurrentOutlet21 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.22Scalaroutlet22ONdlyread-writecurrentOutlet22 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.23Scalaroutlet23ONdlyread-writecurrentOutlet23 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.17.24Scalaroutlet24ONdlyread-writecurrentOutlet24 power-on delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18NodereceptacleResetDelay
1.3.6.1.4.1.30932.1.1.2.18.1Scalaroutlet1RESdlyread-writecurrentOutlet1 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.2Scalaroutlet2RESdlyread-writecurrentOutlet2 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.3Scalaroutlet3RESdlyread-writecurrentOutlet3 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.4Scalaroutlet4RESdlyread-writecurrentOutlet4 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.5Scalaroutlet5RESdlyread-writecurrentOutlet5 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.6Scalaroutlet6RESdlyread-writecurrentOutlet6 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.7Scalaroutlet7RESdlyread-writecurrentOutlet7 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.8Scalaroutlet8RESdlyread-writecurrentOutlet8 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.9Scalaroutlet9RESdlyread-writecurrentOutlet9 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.10Scalaroutlet10RESdlyread-writecurrentOutlet10 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.11Scalaroutlet11RESdlyread-writecurrentOutlet11 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.12Scalaroutlet12RESdlyread-writecurrentOutlet12 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.13Scalaroutlet13RESdlyread-writecurrentOutlet13 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.14Scalaroutlet14RESdlyread-writecurrentOutlet14 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.15Scalaroutlet15RESdlyread-writecurrentOutlet15 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.16Scalaroutlet16RESdlyread-writecurrentOutlet16 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.17Scalaroutlet17RESdlyread-writecurrentOutlet17 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.18Scalaroutlet18RESdlyread-writecurrentOutlet18 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.19Scalaroutlet19RESdlyread-writecurrentOutlet19 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.20Scalaroutlet20RESdlyread-writecurrentOutlet20 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.21Scalaroutlet21RESdlyread-writecurrentOutlet21 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.22Scalaroutlet22RESdlyread-writecurrentOutlet22 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.23Scalaroutlet23RESdlyread-writecurrentOutlet23 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.18.24Scalaroutlet24RESdlyread-writecurrentOutlet24 reset delay in seconds.
1.3.6.1.4.1.30932.1.1.2.19NodemaxCurrentLimits
1.3.6.1.4.1.30932.1.1.2.19.1Scalarxy1MaxCurrread-writecurrentMaximum current that XY1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.19.2Scalaryz1MaxCurrread-writecurrentMaximum current that YZ1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.19.3Scalarzx1MaxCurrread-writecurrentMaximum current that ZX1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.19.4Scalarxy2MaxCurrread-writecurrentMaximum current that XY2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.19.5Scalaryz2MaxCurrread-writecurrentMaximum current that YZ2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.19.6Scalarzx2MaxCurrread-writecurrentMaximum current that ZX2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.20NodeminCurrentLimits
1.3.6.1.4.1.30932.1.1.2.20.1Scalarxy1MinCurrread-writecurrentMinimum current that XY1 should draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.20.2Scalaryz1MinCurrread-writecurrentMinimum current that YZ1 should draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.20.3Scalarzx1MinCurrread-writecurrentMinimum current that ZX1 should draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.20.4Scalarxy2MinCurrread-writecurrentMinimum current that XY2 should draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.20.5Scalaryz2MinCurrread-writecurrentMinimum current that YZ2 should draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.20.6Scalarzx2MinCurrread-writecurrentMinimum current that ZX2 should draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.21NodewarnHiCurrentLimits
1.3.6.1.4.1.30932.1.1.2.21.1Scalarxy1WarnHiCurrread-writecurrentWarning upper current limit that XY1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.21.2Scalaryz1WarnHiCurrread-writecurrentWarning upper current limit that YZ1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.21.3Scalarzx1WarnHiCurrread-writecurrentWarning upper current limit that ZX1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.21.4Scalarxy2WarnHiCurrread-writecurrentWarning upper current limit that XY2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.21.5Scalaryz2WarnHiCurrread-writecurrentWarning upper current limit that YZ2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.21.6Scalarzx2WarnHiCurrread-writecurrentWarning upper current limit that ZX2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.22NodewarnLoCurrentLimits
1.3.6.1.4.1.30932.1.1.2.22.1Scalarxy1WarnLoCurrread-writecurrentWarning lower current limit that XY1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.22.2Scalaryz1WarnLoCurrread-writecurrentWarning lower current limit that YZ1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.22.3Scalarzx1WarnLoCurrread-writecurrentWarning lower current limit that ZX1 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.22.4Scalarxy2WarnLoCurrread-writecurrentWarning lower current limit that XY2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.22.5Scalaryz2WarnLoCurrread-writecurrentWarning lower current limit that YZ2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.22.6Scalarzx2WarnLoCurrread-writecurrentWarning lower current limit that ZX2 can draw in 1/100 Amps, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.24NodemaxVoltageLimits
1.3.6.1.4.1.30932.1.1.2.24.1Scalarxy1MaxVoltread-writecurrentMaximum voltage that XY1 can reach up to in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.24.2Scalaryz1MaxVoltread-writecurrentMaximum voltage that YZ1 can reach up to in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.24.3Scalarzx1MaxVoltread-writecurrentMaximum voltage that ZX1 can reach up to in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.24.4Scalarxy2MaxVoltread-writecurrentMaximum voltage that XY2 can reach up to in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.24.5Scalaryz2MaxVoltread-writecurrentMaximum voltage that YZ2 can reach up to in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.24.6Scalarzx2MaxVoltread-writecurrentMaximum voltage that ZX2 can reach up to in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.25NodeminVoltageLimits
1.3.6.1.4.1.30932.1.1.2.25.1Scalarxy1MinVoltread-writecurrentMinimum voltage that XY1 can sag in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.25.2Scalaryz1MinVoltread-writecurrentMinimum voltage that YZ1 can sag in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.25.3Scalarzx1MinVoltread-writecurrentMinimum voltage that ZX1 can sag in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.25.4Scalarxy2MinVoltread-writecurrentMinimum voltage that XY2 can sag in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.25.5Scalaryz2MinVoltread-writecurrentMinimum voltage that YZ2 can sag in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.25.6Scalarzx2MinVoltread-writecurrentMinimum voltage that ZX2 can sag in volts, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.26NodewarnHiVoltageLimits
1.3.6.1.4.1.30932.1.1.2.26.1Scalarxy1WarnHiVoltread-writecurrentWarning High voltage in volts that XY1 can reach before triggering warning notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.26.2Scalaryz1WarnHiVoltread-writecurrentWarning High voltage in volts that YZ1 can reach before triggering warning notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.26.3Scalarzx1WarnHiVoltread-writecurrentWarning High voltage in volts that ZX1 can reach before triggering warning notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.26.4Scalarxy2WarnHiVoltread-writecurrentWarning High voltage in volts that XY2 can reach before triggering warning notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.26.5Scalaryz2WarnHiVoltread-writecurrentWarning High voltage in volts that YZ2 can reach before triggering warning notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.26.6Scalarzx2WarnHiVoltread-writecurrentWarning High voltage in volts that ZX2 can reach before triggering warning notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.27NodewarnLoVoltageLimits
1.3.6.1.4.1.30932.1.1.2.27.1Scalarxy1WarnLoVoltread-writecurrentWarning Low voltage in volts that XY1 can sag before triggering notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.27.2Scalaryz1WarnLoVoltread-writecurrentWarning Low voltage in volts that YZ1 can sag before triggering notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.27.3Scalarzx1WarnLoVoltread-writecurrentWarning Low voltage in volts that ZX1 can sag before triggering notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.27.4Scalarxy2WarnLoVoltread-writecurrentWarning Low voltage in volts that XY2 can sag before triggering notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.27.5Scalaryz2WarnLoVoltread-writecurrentWarning Low voltage in volts that YZ2 can sag before triggering notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.27.6Scalarzx2WarnLoVoltread-writecurrentWarning Low voltage in volts that ZX2 can sag before triggering notifications, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.28NodereceptacleMaxCurrent
1.3.6.1.4.1.30932.1.1.2.28.1Scalaroutlet1MaxCurrread-writecurrentOutlet1 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.2Scalaroutlet2MaxCurrread-writecurrentOutlet2 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.3Scalaroutlet3MaxCurrread-writecurrentOutlet3 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.4Scalaroutlet4MaxCurrread-writecurrentOutlet4 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.5Scalaroutlet5MaxCurrread-writecurrentOutlet5 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.6Scalaroutlet6MaxCurrread-writecurrentOutlet6 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.7Scalaroutlet7MaxCurrread-writecurrentOutlet7 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.8Scalaroutlet8MaxCurrread-writecurrentOutlet8 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.9Scalaroutlet9MaxCurrread-writecurrentOutlet9 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.10Scalaroutlet10MaxCurrread-writecurrentOutlet10 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.11Scalaroutlet11MaxCurrread-writecurrentOutlet11 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.12Scalaroutlet12MaxCurrread-writecurrentOutlet12 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.13Scalaroutlet13MaxCurrread-writecurrentOutlet13 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.14Scalaroutlet14MaxCurrread-writecurrentOutlet14 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.15Scalaroutlet15MaxCurrread-writecurrentOutlet15 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.16Scalaroutlet16MaxCurrread-writecurrentOutlet16 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.17Scalaroutlet17MaxCurrread-writecurrentOutlet17 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.18Scalaroutlet18MaxCurrread-writecurrentOutlet18 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.19Scalaroutlet19MaxCurrread-writecurrentOutlet19 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.20Scalaroutlet20MaxCurrread-writecurrentOutlet20 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.21Scalaroutlet21MaxCurrread-writecurrentOutlet21 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.22Scalaroutlet22MaxCurrread-writecurrentOutlet22 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.23Scalaroutlet23MaxCurrread-writecurrentOutlet23 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.28.24Scalaroutlet24MaxCurrread-writecurrentOutlet24 maximum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29NodereceptacleMinCurrent
1.3.6.1.4.1.30932.1.1.2.29.1Scalaroutlet1MinCurrread-writecurrentOutlet1 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.2Scalaroutlet2MinCurrread-writecurrentOutlet2 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.3Scalaroutlet3MinCurrread-writecurrentOutlet3 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.4Scalaroutlet4MinCurrread-writecurrentOutlet4 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.5Scalaroutlet5MinCurrread-writecurrentOutlet5 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.6Scalaroutlet6MinCurrread-writecurrentOutlet6 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.7Scalaroutlet7MinCurrread-writecurrentOutlet7 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.8Scalaroutlet8MinCurrread-writecurrentOutlet8 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.9Scalaroutlet9MinCurrread-writecurrentOutlet9 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.10Scalaroutlet10MinCurrread-writecurrentOutlet10 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.11Scalaroutlet11MinCurrread-writecurrentOutlet11 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.12Scalaroutlet12MinCurrread-writecurrentOutlet12 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.13Scalaroutlet13MinCurrread-writecurrentOutlet13 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.14Scalaroutlet14MinCurrread-writecurrentOutlet14 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.15Scalaroutlet15MinCurrread-writecurrentOutlet15 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.16Scalaroutlet16MinCurrread-writecurrentOutlet16 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.17Scalaroutlet17MinCurrread-writecurrentOutlet17 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.18Scalaroutlet18MinCurrread-writecurrentOutlet18 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.19Scalaroutlet19MinCurrread-writecurrentOutlet19 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.20Scalaroutlet20MinCurrread-writecurrentOutlet20 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.21Scalaroutlet21MinCurrread-writecurrentOutlet21 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.22Scalaroutlet22MinCurrread-writecurrentOutlet22 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.23Scalaroutlet23MinCurrread-writecurrentOutlet23 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.29.24Scalaroutlet24MinCurrread-writecurrentOutlet24 minimum current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30NodereceptacleWarnHiCurrent
1.3.6.1.4.1.30932.1.1.2.30.1Scalaroutlet1WarnHiCurrread-writecurrentOutlet1 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.2Scalaroutlet2WarnHiCurrread-writecurrentOutlet2 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.3Scalaroutlet3WarnHiCurrread-writecurrentOutlet3 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.4Scalaroutlet4WarnHiCurrread-writecurrentOutlet4 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.5Scalaroutlet5WarnHiCurrread-writecurrentOutlet5 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.6Scalaroutlet6WarnHiCurrread-writecurrentOutlet6 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.7Scalaroutlet7WarnHiCurrread-writecurrentOutlet7 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.8Scalaroutlet8WarnHiCurrread-writecurrentOutlet8 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.9Scalaroutlet9WarnHiCurrread-writecurrentOutlet9 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.10Scalaroutlet10WarnHiCurrread-writecurrentOutlet10 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.11Scalaroutlet11WarnHiCurrread-writecurrentOutlet11 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.12Scalaroutlet12WarnHiCurrread-writecurrentOutlet12 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.13Scalaroutlet13WarnHiCurrread-writecurrentOutlet13 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.14Scalaroutlet14WarnHiCurrread-writecurrentOutlet14 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.15Scalaroutlet15WarnHiCurrread-writecurrentOutlet15 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.16Scalaroutlet16WarnHiCurrread-writecurrentOutlet16 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.17Scalaroutlet17WarnHiCurrread-writecurrentOutlet17 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.18Scalaroutlet18WarnHiCurrread-writecurrentOutlet18 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.19Scalaroutlet19WarnHiCurrread-writecurrentOutlet19 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.20Scalaroutlet20WarnHiCurrread-writecurrentOutlet20 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.21Scalaroutlet21WarnHiCurrread-writecurrentOutlet21 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.22Scalaroutlet22WarnHiCurrread-writecurrentOutlet22 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.23Scalaroutlet23WarnHiCurrread-writecurrentOutlet23 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.30.24Scalaroutlet24WarnHiCurrread-writecurrentOutlet24 warning high current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31NodereceptacleWarnLoCurrent
1.3.6.1.4.1.30932.1.1.2.31.1Scalaroutlet1WarnLoCurrread-writecurrentOutlet1 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.2Scalaroutlet2WarnLoCurrread-writecurrentOutlet2 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.3Scalaroutlet3WarnLoCurrread-writecurrentOutlet3 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.4Scalaroutlet4WarnLoCurrread-writecurrentOutlet4 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.5Scalaroutlet5WarnLoCurrread-writecurrentOutlet5 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.6Scalaroutlet6WarnLoCurrread-writecurrentOutlet6 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.7Scalaroutlet7WarnLoCurrread-writecurrentOutlet7 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.8Scalaroutlet8WarnLoCurrread-writecurrentOutlet8 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.9Scalaroutlet9WarnLoCurrread-writecurrentOutlet9 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.10Scalaroutlet10WarnLoCurrread-writecurrentOutlet10 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.11Scalaroutlet11WarnLoCurrread-writecurrentOutlet11 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.12Scalaroutlet12WarnLoCurrread-writecurrentOutlet12 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.13Scalaroutlet13WarnLoCurrread-writecurrentOutlet13 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.14Scalaroutlet14WarnLoCurrread-writecurrentOutlet14 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.15Scalaroutlet15WarnLoCurrread-writecurrentOutlet15 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.16Scalaroutlet16WarnLoCurrread-writecurrentOutlet16 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.17Scalaroutlet17WarnLoCurrread-writecurrentOutlet17 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.18Scalaroutlet18WarnLoCurrread-writecurrentOutlet18 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.19Scalaroutlet19WarnLoCurrread-writecurrentOutlet19 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.20Scalaroutlet20WarnLoCurrread-writecurrentOutlet20 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.21Scalaroutlet21WarnLoCurrread-writecurrentOutlet21 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.22Scalaroutlet22WarnLoCurrread-writecurrentOutlet22 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.23Scalaroutlet23WarnLoCurrread-writecurrentOutlet23 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.31.24Scalaroutlet24WarnLoCurrread-writecurrentOutlet24 warning low current in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.2.32NodemaxTempLimits
1.3.6.1.4.1.30932.1.1.2.32.1ScalarmaxTempProbe1read-writecurrentMaximum temperature for Probe 1 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.32.2ScalarmaxTempProbe2read-writecurrentMaximum temperature for Probe 2 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.33NodeminTempLimits
1.3.6.1.4.1.30932.1.1.2.33.1ScalarminTempProbe1read-writecurrentMinimum temperature for Probe 1 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.33.2ScalarminTempProbe2read-writecurrentMinimum temperature for Probe 2 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.34NodewarnHiTempLimits
1.3.6.1.4.1.30932.1.1.2.34.1ScalarwarnHiTempProbe1read-writecurrentWarning High temperature for Probe 1 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.34.2ScalarwarnHiTempProbe2read-writecurrentWarning High temperature for Probe 2 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.35NodewarnLoTempLimits
1.3.6.1.4.1.30932.1.1.2.35.1ScalarwarnLoTempProbe1read-writecurrentWarning Low temperature for Probe 1 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.35.2ScalarwarnLoTempProbe2read-writecurrentWarning Low temperature for Probe 2 in 1/100 of degrees Fahrenheit, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.36NodemaxHumidityLimits
1.3.6.1.4.1.30932.1.1.2.36.1ScalarmaxHumidProbe1read-writecurrentMaximum humidity for Probe 1 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.36.2ScalarmaxHumidProbe2read-writecurrentMaximum humidity for Probe 2 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.37NodeminHumidityLimits
1.3.6.1.4.1.30932.1.1.2.37.1ScalarminHumidProbe1read-writecurrentMinimum humidity for Probe 1 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.37.2ScalarminHumidProbe2read-writecurrentMinimum humidity for Probe 2 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.38NodewarnHiHumidityLimits
1.3.6.1.4.1.30932.1.1.2.38.1ScalarwarnHiHumidProbe1read-writecurrentWarning High humidity for Probe 1 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.38.2ScalarwarnHiHumidProbe2read-writecurrentWarning High humidity for Probe 2 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.39NodewarnLoHumidityLimits
1.3.6.1.4.1.30932.1.1.2.39.1ScalarwarnLoHumidProbe1read-writecurrentWarning Low humidity for Probe 1 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.39.2ScalarwarnLoHumidProbe2read-writecurrentWarning Low humidity for Probe 2 in 1/100 of %, 0=ignore.
1.3.6.1.4.1.30932.1.1.2.40ScalarpduNameread-writecurrentPDU Name.
1.3.6.1.4.1.30932.1.1.2.41ScalarpduDescripread-writecurrentPDU Description.
1.3.6.1.4.1.30932.1.1.2.42NodereceptacleNames
1.3.6.1.4.1.30932.1.1.2.42.1Scalaroutlet1Nameread-writecurrentOutlet1 Name.
1.3.6.1.4.1.30932.1.1.2.42.2Scalaroutlet2Nameread-writecurrentOutlet2 Name.
1.3.6.1.4.1.30932.1.1.2.42.3Scalaroutlet3Nameread-writecurrentOutlet3 Name.
1.3.6.1.4.1.30932.1.1.2.42.4Scalaroutlet4Nameread-writecurrentOutlet4 Name.
1.3.6.1.4.1.30932.1.1.2.42.5Scalaroutlet5Nameread-writecurrentOutlet5 Name.
1.3.6.1.4.1.30932.1.1.2.42.6Scalaroutlet6Nameread-writecurrentOutlet6 Name.
1.3.6.1.4.1.30932.1.1.2.42.7Scalaroutlet7Nameread-writecurrentOutlet7 Name.
1.3.6.1.4.1.30932.1.1.2.42.8Scalaroutlet8Nameread-writecurrentOutlet8 Name.
1.3.6.1.4.1.30932.1.1.2.42.9Scalaroutlet9Nameread-writecurrentOutlet9 Name.
1.3.6.1.4.1.30932.1.1.2.42.10Scalaroutlet10Nameread-writecurrentOutlet10 Name.
1.3.6.1.4.1.30932.1.1.2.42.11Scalaroutlet11Nameread-writecurrentOutlet11 Name.
1.3.6.1.4.1.30932.1.1.2.42.12Scalaroutlet12Nameread-writecurrentOutlet12 Name.
1.3.6.1.4.1.30932.1.1.2.42.13Scalaroutlet13Nameread-writecurrentOutlet13 Name.
1.3.6.1.4.1.30932.1.1.2.42.14Scalaroutlet14Nameread-writecurrentOutlet14 Name.
1.3.6.1.4.1.30932.1.1.2.42.15Scalaroutlet15Nameread-writecurrentOutlet15 Name.
1.3.6.1.4.1.30932.1.1.2.42.16Scalaroutlet16Nameread-writecurrentOutlet16 Name.
1.3.6.1.4.1.30932.1.1.2.42.17Scalaroutlet17Nameread-writecurrentOutlet17 Name.
1.3.6.1.4.1.30932.1.1.2.42.18Scalaroutlet18Nameread-writecurrentOutlet18 Name.
1.3.6.1.4.1.30932.1.1.2.42.19Scalaroutlet19Nameread-writecurrentOutlet19 Name.
1.3.6.1.4.1.30932.1.1.2.42.20Scalaroutlet20Nameread-writecurrentOutlet20 Name.
1.3.6.1.4.1.30932.1.1.2.42.21Scalaroutlet21Nameread-writecurrentOutlet21 Name.
1.3.6.1.4.1.30932.1.1.2.42.22Scalaroutlet22Nameread-writecurrentOutlet22 Name.
1.3.6.1.4.1.30932.1.1.2.42.23Scalaroutlet23Nameread-writecurrentOutlet23 Name.
1.3.6.1.4.1.30932.1.1.2.42.24Scalaroutlet24Nameread-writecurrentOutlet24 Name.
1.3.6.1.4.1.30932.1.1.2.43NodereceptacleDescrips
1.3.6.1.4.1.30932.1.1.2.43.1Scalaroutlet1Descripread-writecurrentOutlet1 Description.
1.3.6.1.4.1.30932.1.1.2.43.2Scalaroutlet2Descripread-writecurrentOutlet2 Description.
1.3.6.1.4.1.30932.1.1.2.43.3Scalaroutlet3Descripread-writecurrentOutlet3 Description.
1.3.6.1.4.1.30932.1.1.2.43.4Scalaroutlet4Descripread-writecurrentOutlet4 Description.
1.3.6.1.4.1.30932.1.1.2.43.5Scalaroutlet5Descripread-writecurrentOutlet5 Description.
1.3.6.1.4.1.30932.1.1.2.43.6Scalaroutlet6Descripread-writecurrentOutlet6 Description.
1.3.6.1.4.1.30932.1.1.2.43.7Scalaroutlet7Descripread-writecurrentOutlet7 Description.
1.3.6.1.4.1.30932.1.1.2.43.8Scalaroutlet8Descripread-writecurrentOutlet8 Description.
1.3.6.1.4.1.30932.1.1.2.43.9Scalaroutlet9Descripread-writecurrentOutlet9 Description.
1.3.6.1.4.1.30932.1.1.2.43.10Scalaroutlet10Descripread-writecurrentOutlet10 Description.
1.3.6.1.4.1.30932.1.1.2.43.11Scalaroutlet11Descripread-writecurrentOutlet11 Description.
1.3.6.1.4.1.30932.1.1.2.43.12Scalaroutlet12Descripread-writecurrentOutlet12 Description.
1.3.6.1.4.1.30932.1.1.2.43.13Scalaroutlet13Descripread-writecurrentOutlet13 Description.
1.3.6.1.4.1.30932.1.1.2.43.14Scalaroutlet14Descripread-writecurrentOutlet14 Description.
1.3.6.1.4.1.30932.1.1.2.43.15Scalaroutlet15Descripread-writecurrentOutlet15 Description.
1.3.6.1.4.1.30932.1.1.2.43.16Scalaroutlet16Descripread-writecurrentOutlet16 Description.
1.3.6.1.4.1.30932.1.1.2.43.17Scalaroutlet17Descripread-writecurrentOutlet17 Description.
1.3.6.1.4.1.30932.1.1.2.43.18Scalaroutlet18Descripread-writecurrentOutlet18 Description.
1.3.6.1.4.1.30932.1.1.2.43.19Scalaroutlet19Descripread-writecurrentOutlet19 Description.
1.3.6.1.4.1.30932.1.1.2.43.20Scalaroutlet20Descripread-writecurrentOutlet20 Description.
1.3.6.1.4.1.30932.1.1.2.43.21Scalaroutlet21Descripread-writecurrentOutlet21 Description.
1.3.6.1.4.1.30932.1.1.2.43.22Scalaroutlet22Descripread-writecurrentOutlet22 Description.
1.3.6.1.4.1.30932.1.1.2.43.23Scalaroutlet23Descripread-writecurrentOutlet23 Description.
1.3.6.1.4.1.30932.1.1.2.43.24Scalaroutlet24Descripread-writecurrentOutlet24 Description.
1.3.6.1.4.1.30932.1.1.2.50NodegroupNames
1.3.6.1.4.1.30932.1.1.2.50.1Scalargroup1Nameread-writecurrentName for GROUP 1 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.2Scalargroup2Nameread-writecurrentName for GROUP 2 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.3Scalargroup3Nameread-writecurrentName for GROUP 3 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.4Scalargroup4Nameread-writecurrentName for GROUP 4 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.5Scalargroup5Nameread-writecurrentName for GROUP 5 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.6Scalargroup6Nameread-writecurrentName for GROUP 6 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.7Scalargroup7Nameread-writecurrentName for GROUP 7 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.8Scalargroup8Nameread-writecurrentName for GROUP 8 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.9Scalargroup9Nameread-writecurrentName for GROUP 9 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.10Scalargroup10Nameread-writecurrentName for GROUP 10 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.11Scalargroup11Nameread-writecurrentName for GROUP 11 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.12Scalargroup12Nameread-writecurrentName for GROUP 12 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.13Scalargroup13Nameread-writecurrentName for GROUP 13 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.14Scalargroup14Nameread-writecurrentName for GROUP 14 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.15Scalargroup15Nameread-writecurrentName for GROUP 15 of receptacles.
1.3.6.1.4.1.30932.1.1.2.50.16Scalargroup16Nameread-writecurrentName for GROUP 16 of receptacles.
1.3.6.1.4.1.30932.1.1.2.51NodegroupMaps
1.3.6.1.4.1.30932.1.1.2.51.1Scalargroup1Mapread-writecurrentMap for Group 1 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.2Scalargroup2Mapread-writecurrentMap for Group 2 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.3Scalargroup3Mapread-writecurrentMap for Group 3 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.4Scalargroup4Mapread-writecurrentMap for Group 4 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.5Scalargroup5Mapread-writecurrentMap for Group 5 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.6Scalargroup6Mapread-writecurrentMap for Group 6 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.7Scalargroup7Mapread-writecurrentMap for Group 7 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.8Scalargroup8Mapread-writecurrentMap for Group 8 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.9Scalargroup9Mapread-writecurrentMap for Group 9 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.10Scalargroup10Mapread-writecurrentMap for Group 10 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.11Scalargroup11Mapread-writecurrentMap for Group 11 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.12Scalargroup12Mapread-writecurrentMap for Group 12 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.13Scalargroup13Mapread-writecurrentMap for Group 13 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.14Scalargroup14Mapread-writecurrentMap for Group 14 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.15Scalargroup15Mapread-writecurrentMap for Group 15 of receptacels.
1.3.6.1.4.1.30932.1.1.2.51.16Scalargroup16Mapread-writecurrentMap for Group 16 of receptacels.
1.3.6.1.4.1.30932.1.1.2.55ScalardispTimeoutread-writecurrentInactivity timeout in minutes to blank the local display (minimum is 1 minute).
1.3.6.1.4.1.30932.1.1.2.56ScalarloginTimeoutread-writecurrentInactivity timeout in minutes to terminate a logged in session (minimum is 1 minute).
1.3.6.1.4.1.30932.1.1.2.57ScalardispBrightnessread-writecurrentThe relative brightness of the local display (0 in min, 9 is max).
1.3.6.1.4.1.30932.1.1.2.58NodepduOptions
1.3.6.1.4.1.30932.1.1.2.58.1ScalarinputTopread-writecurrentInput cord entry orientation, 1 = top, 0 = bottom.
1.3.6.1.4.1.30932.1.1.2.58.2ScalarpduRoleread-writecurrentPDU Role, 1 = primary, 0 = secondary.
1.3.6.1.4.1.30932.1.1.2.58.3ScalarcelsiusTempread-writecurrentTemperature units, 1=Celsius, 0=Fahrenheit.
1.3.6.1.4.1.30932.1.1.2.58.4ScalarenableWebread-writecurrentEnable Web Access, 1 = enable, 0 = disable.
1.3.6.1.4.1.30932.1.1.2.58.5ScalarsnmpHostOnlyread-writecurrentRestrict access to SNMP via listed Hosts only, 1 = listed SNMP hosts only, 0 = any host.
1.3.6.1.4.1.30932.1.1.2.58.6ScalardisLocalAuthread-writecurrentDisable local authentication, 1 = disable, 0 = enable.
1.3.6.1.4.1.30932.1.1.2.58.7ScalarenaRadiusAuthread-writecurrentEnable Radius authentication, 1 = disable, 0 = enable.
1.3.6.1.4.1.30932.1.1.2.58.8ScalarenaADAuthread-writecurrentEnable Active Directory authentication, 1 = disable, 0 = enable.
1.3.6.1.4.1.30932.1.1.2.58.9ScalarenaSMTPread-writecurrentEnable Mail Notification, 1 = disable, 0 = enable.
1.3.6.1.4.1.30932.1.1.2.58.10ScalarpduAltRoleread-writecurrentPDU Alternate Role, 1 = alternate, 0 = secondary.
1.3.6.1.4.1.30932.1.1.2.58.11ScalarshareRoleread-writecurrentAllow sharing of PDU Primary and Alternate Roles, 1 = shared, 0 = backup only.
1.3.6.1.4.1.30932.1.1.2.58.12ScalaroutOfServiceread-writecurrentRemove a PDU from normal operation, 1 = out of service, 0 = normal operation.
1.3.6.1.4.1.30932.1.1.2.58.13ScalarmissingPDUNotifyread-writecurrentNotify when a PDU is missing from the link, 1 = enable, 0 = disable.
1.3.6.1.4.1.30932.1.1.2.58.14ScalarroleChangeNotifyread-writecurrentNotify when a PDU changes role in the link, 1 = enable, 0 = disable.
1.3.6.1.4.1.30932.1.1.2.58.15ScalarsumAmpread-writecurrentDisplay the sum of the current across branches, 1 = enable, 0 = disable.
1.3.6.1.4.1.30932.1.1.2.59NodehttpPorts
1.3.6.1.4.1.30932.1.1.2.59.1ScalarhttpPortread-writecurrentPort for unsecure HTTP access.
1.3.6.1.4.1.30932.1.1.2.59.2ScalarhttpsPortread-writecurrentPort for secure HTTPS access.
1.3.6.1.4.1.30932.1.1.2.60NodesshPorts
1.3.6.1.4.1.30932.1.1.2.60.1ScalarsshPortread-writecurrentPort for secure SSH access.
1.3.6.1.4.1.30932.1.1.2.60.2ScalartelnetPortread-writecurrentPort for non secure Telnet access.
1.3.6.1.4.1.30932.1.1.2.61NodesnmpPorts
1.3.6.1.4.1.30932.1.1.2.61.1ScalarsnmpQueryPortread-writecurrentPort for SNMP query access.
1.3.6.1.4.1.30932.1.1.2.61.2ScalarsnmpTrapPortread-writecurrentPort for SNMP trap.
1.3.6.1.4.1.30932.1.1.2.62NodesmtpPorts
1.3.6.1.4.1.30932.1.1.2.62.1ScalarsmtpSendPortread-writecurrentPort for SMTP send.
1.3.6.1.4.1.30932.1.1.2.62.2ScalarsmtpReceivePortread-writecurrentPort for SMTP Receive.
1.3.6.1.4.1.30932.1.1.2.63ScalarrfcTimeServerread-writecurrentRFC Time Server Address.
1.3.6.1.4.1.30932.1.1.2.64ScalarntpTimeServerread-writecurrentNTP Time Server Address.
1.3.6.1.4.1.30932.1.1.2.65ScalarsmtpServerread-writecurrentEmail Server Address.
1.3.6.1.4.1.30932.1.1.2.66ScalarsnmpReadCommread-writecurrentSNMP Read Community.
1.3.6.1.4.1.30932.1.1.2.67ScalarsnmpWriteCommread-writecurrentSNMP Write Community.
1.3.6.1.4.1.30932.1.1.2.68ScalarsnmpUSMuserNameread-writecurrentSNMP USM User Name.
1.3.6.1.4.1.30932.1.1.2.69NodesnmpSecurityLevelAlgorithm
1.3.6.1.4.1.30932.1.1.2.69.1ScalarsnmpSecurityLevelread-writecurrentSecurity Level for SNMP: 0 = v1, 1 = v2c, 2 = v3 no authentication, 3 = v3 with authentication only, 4 = v3 with authentication and privacy
1.3.6.1.4.1.30932.1.1.2.69.2ScalarsnmpAuthAlgoread-writecurrentAuthentication Algorithm for SNMP: 0 = SHA, 1 = MD5.
1.3.6.1.4.1.30932.1.1.2.69.3ScalarsnmpPrivAlgoread-writecurrentPrivacy Algorithm for SNMP: 0 = DES, 1 = AES.
1.3.6.1.4.1.30932.1.1.2.70ScalarsnmpAuthPasswdread-writecurrentSNMP Authentication Password.
1.3.6.1.4.1.30932.1.1.2.71ScalarsnmpPrivPasswdread-writecurrentSNMP Privacy Password.
1.3.6.1.4.1.30932.1.1.2.72ScalarsnmpContextNameread-writecurrentSNMP Context Name.
1.3.6.1.4.1.30932.1.1.2.73ScalarsnmpEngineIDread-writecurrentSNMP Engine ID.
1.3.6.1.4.1.30932.1.1.2.74ScalarsnmpLocAuthKeyread-writecurrentSNMP Local Authentication Key.
1.3.6.1.4.1.30932.1.1.2.75ScalarsnmpLocPrivKeyread-writecurrentSNMP Local Privacy Key.
1.3.6.1.4.1.30932.1.1.2.76ScalarsmtpUserNameread-writecurrentPDU Email User Login Name.
1.3.6.1.4.1.30932.1.1.2.77ScalarsmtpUserPasswdread-writecurrentPDU Email User Login Password.
1.3.6.1.4.1.30932.1.1.2.78ScalarsmtpEmailAddrread-writecurrentPDU Email address.
1.3.6.1.4.1.30932.1.1.2.79NodesmtpEmailDestinations
1.3.6.1.4.1.30932.1.1.2.79.1ScalarsmtpEmailDestination1read-writecurrentEmail destination for recipient 0.
1.3.6.1.4.1.30932.1.1.2.79.2ScalarsmtpEmailDestination2read-writecurrentEmail destination for recipient 1.
1.3.6.1.4.1.30932.1.1.2.79.3ScalarsmtpEmailDestination3read-writecurrentEmail destination for recipient 2.
1.3.6.1.4.1.30932.1.1.2.80ScalarsmtpServOptionsread-writecurrentSMTP Server Options.
1.3.6.1.4.1.30932.1.1.2.81ScalarradiusServerread-writecurrentRadius Authentication Server.
1.3.6.1.4.1.30932.1.1.2.82ScalarradiusSHSecretread-writecurrentRadius Shared Secret.
1.3.6.1.4.1.30932.1.1.2.83ScalarradiusNASServerread-writecurrentRadius Network Access Service.
1.3.6.1.4.1.30932.1.1.2.84NoderadiusNASPorts
1.3.6.1.4.1.30932.1.1.2.84.1ScalarradiusPortread-writecurrentPort for radius authentication.
1.3.6.1.4.1.30932.1.1.2.84.2ScalarnasPortread-writecurrentPort for Radius Network Access Service.
1.3.6.1.4.1.30932.1.1.2.85ScalaradServerread-writecurrentActive Directory Server.
1.3.6.1.4.1.30932.1.1.2.86ScalaradDomainread-writecurrentActive Directory Domain.
1.3.6.1.4.1.30932.1.1.2.87NodeadAllPorts
1.3.6.1.4.1.30932.1.1.2.87.1ScalaradPortread-writecurrentPort for Active Directory authentication.
1.3.6.1.4.1.30932.1.1.2.87.2ScalaradResvPortread-writecurrentAlternate or reserved port for Active Directory Authentication.
1.3.6.1.4.1.30932.1.1.2.88NodeenvProbeNames
1.3.6.1.4.1.30932.1.1.2.88.1Scalarprobe1Nameread-writecurrentName for Environmental Probe 1.
1.3.6.1.4.1.30932.1.1.2.88.2Scalarprobe2Nameread-writecurrentName for Environmental Probe 2.
1.3.6.1.4.1.30932.1.1.2.89NodedLogOptions
1.3.6.1.4.1.30932.1.1.2.89.1ScalardLogEnableread-writecurrentEnable data logging feature, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.2ScalarstdmeterdLogread-writecurrentEnable logging of branch, receptacle and environmental metrics, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.3ScalargroupmeterdLogread-writecurrentEnable logging of grouped receptacle metrics, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.4ScalaralarmdLogread-writecurrentEnable logging of alarm events, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.5ScalaruserlogindLogread-writecurrentEnable logging of user login events, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.6ScalarusersetupdLogread-writecurrentEnable logging of user setup change events, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.7ScalarfwupdatedLogread-writecurrentEnable data logging feature, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.8ScalarsetupchangedLogread-writecurrentEnable logging of setup change events, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.9ScalarrecepchangedLogread-writecurrentEnable logging of receptacle state changes, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.10ScalarpduopchangedLogread-writecurrentEnable logging of PDU operation and state changes, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.11ScalarnetservdLogread-writecurrentEnable data logging to log server over network, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.89.12ScalarautonetLogread-writecurrentEnable automatic transfer to log server every 6 hours, 0=disable and 1=enable.
1.3.6.1.4.1.30932.1.1.2.90ScalardLogCycleread-writecurrentThe time interval in minutes for internal data logging to occur.
1.3.6.1.4.1.30932.1.1.2.91ScalardLogFullWarnLevelread-writecurrentThe warning threshold for percentage of storage full (min=50, max=100).
1.3.6.1.4.1.30932.1.1.2.92ScalarnetdLogServerread-writecurrentThe network address for the data log server.
1.3.6.1.4.1.30932.1.1.2.93ScalarnetdLogPortread-writecurrentThe port used by the data log server.
1.3.6.1.4.1.30932.1.1.2.94ScalarnetdLogUserread-writecurrentThe user name to access the data log server.
1.3.6.1.4.1.30932.1.1.2.95ScalarnetdLogPasswdread-writecurrentThe user password to access the data log server.
1.3.6.1.4.1.30932.1.1.2.96ScalarnetdLogDestdirread-writecurrentThe destination directory in the data log server.
1.3.6.1.4.1.30932.1.1.2.97ScalarnetdLogOptionsread-writecurrentThe options string when accessing the data log server.
1.3.6.1.4.1.30932.1.1.2.98NodesnmpTrapHosts
1.3.6.1.4.1.30932.1.1.2.98.1ScalarsnmpTrapHost1read-writecurrentSNMP Trap Host 1 IP address.
1.3.6.1.4.1.30932.1.1.2.98.2ScalarsnmpTrapHost2read-writecurrentSNMP Trap Host 2 IP address.
1.3.6.1.4.1.30932.1.1.2.98.3ScalarsnmpTrapHost3read-writecurrentSNMP Trap Host 3 IP address.
1.3.6.1.4.1.30932.1.1.2.98.4ScalarsnmpTrapHostIPv61read-writecurrentSet or get the IPv6 address of the first SNMP Trap Host.
1.3.6.1.4.1.30932.1.1.2.98.5ScalarsnmpTrapHostIPv62read-writecurrentSet or get the IPv6 address of the second SNMP Trap Host.
1.3.6.1.4.1.30932.1.1.2.98.6ScalarsnmpTrapHostIPv63read-writecurrentSet or get the IPv6 address of the third SNMP Trap Host.
1.3.6.1.4.1.30932.1.1.2.99NodesnmpTrapHostsIPv6
1.3.6.1.4.1.30932.1.1.2.99.1ScalarsnmpTrapHost1IPv6read-writecurrentSNMP Trap Host 1 IPV6.
1.3.6.1.4.1.30932.1.1.2.99.2ScalarsnmpTrapHost2IPv6read-writecurrentSNMP Trap Host 2 IPV6.
1.3.6.1.4.1.30932.1.1.2.99.3ScalarsnmpTrapHost3IPv6read-writecurrentSNMP Trap Host 3 IPV6.
1.3.6.1.4.1.30932.1.1.2.100ScalarlnkAttachCountread-writecurrentCount of secondary PDUs that are attached to the link.
1.3.6.1.4.1.30932.1.1.3Nodemetrics
1.3.6.1.4.1.30932.1.1.3.1Nodemcurrent
1.3.6.1.4.1.30932.1.1.3.1.1Scalarcurrentxy1read-onlycurrentXY1 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.1.2Scalarcurrentyz1read-onlycurrentYZ1 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.1.3Scalarcurrentzx1read-onlycurrentZX1 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.1.4Scalarcurrentxy2read-onlycurrentXY2 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.1.5Scalarcurrentyz2read-onlycurrentYZ2 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.1.6Scalarcurrentzx2read-onlycurrentZX2 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.2Nodemvoltage
1.3.6.1.4.1.30932.1.1.3.2.1Scalarvoltagexy1read-onlycurrentXY1 voltage in 1/10 volts.
1.3.6.1.4.1.30932.1.1.3.2.2Scalarvoltageyz1read-onlycurrentYZ1 voltage in 1/10 volts.
1.3.6.1.4.1.30932.1.1.3.2.3Scalarvoltagezx1read-onlycurrentZX1 voltage in 1/10 volts.
1.3.6.1.4.1.30932.1.1.3.2.4Scalarvoltagexy2read-onlycurrentXY2 voltage in 1/10 volts.
1.3.6.1.4.1.30932.1.1.3.2.5Scalarvoltageyz2read-onlycurrentYZ2 voltage in 1/10 volts.
1.3.6.1.4.1.30932.1.1.3.2.6Scalarvoltagezx2read-onlycurrentZX2 voltage in 1/10 volts.
1.3.6.1.4.1.30932.1.1.3.3Nodempower
1.3.6.1.4.1.30932.1.1.3.3.1Scalarpowerxy1read-onlycurrentXY1 power consumption in Watts.
1.3.6.1.4.1.30932.1.1.3.3.2Scalarpoweryz1read-onlycurrentYZ1 power consumption in Watts.
1.3.6.1.4.1.30932.1.1.3.3.3Scalarpowerzx1read-onlycurrentZX1 power consumption in Watts.
1.3.6.1.4.1.30932.1.1.3.3.4Scalarpowerxy2read-onlycurrentXY2 power consumption in Watts.
1.3.6.1.4.1.30932.1.1.3.3.5Scalarpoweryz2read-onlycurrentYZ2 power consumption in Watts.
1.3.6.1.4.1.30932.1.1.3.3.6Scalarpowerzx2read-onlycurrentZX2 power consumption in Watts.
1.3.6.1.4.1.30932.1.1.3.4NodempowerFactor
1.3.6.1.4.1.30932.1.1.3.4.1ScalarpowerFactxy1read-onlycurrentXY1 power factor x 100.
1.3.6.1.4.1.30932.1.1.3.4.2ScalarpowerFactyz1read-onlycurrentYZ1 power factor x 100.
1.3.6.1.4.1.30932.1.1.3.4.3ScalarpowerFactzx1read-onlycurrentZX1 power factor x 100.
1.3.6.1.4.1.30932.1.1.3.4.4ScalarpowerFactxy2read-onlycurrentXY2 power factor x 100.
1.3.6.1.4.1.30932.1.1.3.4.5ScalarpowerFactyz2read-onlycurrentYZ2 power factor x 100.
1.3.6.1.4.1.30932.1.1.3.4.6ScalarpowerFactzx2read-onlycurrentZX2 power factor x 100.
1.3.6.1.4.1.30932.1.1.3.5NodereceptacleCurrent
1.3.6.1.4.1.30932.1.1.3.5.1Scalaroutlet1Currentread-onlycurrentOutlet1 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.2Scalaroutlet2Currentread-onlycurrentOutlet2 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.3Scalaroutlet3Currentread-onlycurrentOutlet3 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.4Scalaroutlet4Currentread-onlycurrentOutlet4 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.5Scalaroutlet5Currentread-onlycurrentOutlet5 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.6Scalaroutlet6Currentread-onlycurrentOutlet6 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.7Scalaroutlet7Currentread-onlycurrentOutlet7 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.8Scalaroutlet8Currentread-onlycurrentOutlet8 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.9Scalaroutlet9Currentread-onlycurrentOutlet9 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.10Scalaroutlet10Currentread-onlycurrentOutlet10 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.11Scalaroutlet11Currentread-onlycurrentOutlet11 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.12Scalaroutlet12Currentread-onlycurrentOutlet12 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.13Scalaroutlet13Currentread-onlycurrentOutlet13 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.14Scalaroutlet14Currentread-onlycurrentOutlet14 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.15Scalaroutlet15Currentread-onlycurrentOutlet15 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.16Scalaroutlet16Currentread-onlycurrentOutlet16 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.17Scalaroutlet17Currentread-onlycurrentOutlet17 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.18Scalaroutlet18Currentread-onlycurrentOutlet18 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.19Scalaroutlet19Currentread-onlycurrentOutlet19 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.20Scalaroutlet20Currentread-onlycurrentOutlet20 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.21Scalaroutlet21Currentread-onlycurrentOutlet21 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.22Scalaroutlet22Currentread-onlycurrentOutlet22 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.23Scalaroutlet23Currentread-onlycurrentOutlet23 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.5.24Scalaroutlet24Currentread-onlycurrentOutlet24 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.6ScalarreceptacleCurrentMapread-onlycurrentMap of receptacle currents in ascending order and delimited by space.
1.3.6.1.4.1.30932.1.1.3.7NodereceptacleStatus
1.3.6.1.4.1.30932.1.1.3.7.1Scalaroutlet1Stateread-onlycurrentOutlet1 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.2Scalaroutlet2Stateread-onlycurrentOutlet2 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.3Scalaroutlet3Stateread-onlycurrentOutlet3 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.4Scalaroutlet4Stateread-onlycurrentOutlet4 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.5Scalaroutlet5Stateread-onlycurrentOutlet5 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.6Scalaroutlet6Stateread-onlycurrentOutlet6 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.7Scalaroutlet7Stateread-onlycurrentOutlet7 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.8Scalaroutlet8Stateread-onlycurrentOutlet8 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.9Scalaroutlet9Stateread-onlycurrentOutlet9 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.10Scalaroutlet10Stateread-onlycurrentOutlet10 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.11Scalaroutlet11Stateread-onlycurrentOutlet11 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.12Scalaroutlet12Stateread-onlycurrentOutlet12 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.13Scalaroutlet13Stateread-onlycurrentOutlet13 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.14Scalaroutlet14Stateread-onlycurrentOutlet14 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.15Scalaroutlet15Stateread-onlycurrentOutlet15 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.16Scalaroutlet16Stateread-onlycurrentOutlet16 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.17Scalaroutlet17Stateread-onlycurrentOutlet17 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.18Scalaroutlet18Stateread-onlycurrentOutlet18 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.19Scalaroutlet19Stateread-onlycurrentOutlet19 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.20Scalaroutlet20Stateread-onlycurrentOutlet20 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.21Scalaroutlet21Stateread-onlycurrentOutlet21 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.22Scalaroutlet22Stateread-onlycurrentOutlet22 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.23Scalaroutlet23Stateread-onlycurrentOutlet23 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.7.24Scalaroutlet24Stateread-onlycurrentOutlet24 power state, 0=OFF, 1=ON.
1.3.6.1.4.1.30932.1.1.3.8Nodetemperature
1.3.6.1.4.1.30932.1.1.3.8.1ScalartemperatureProbe1read-onlycurrentProbe 1 temperature in 1/100 degree Fahrenheit.
1.3.6.1.4.1.30932.1.1.3.8.2ScalartemperatureProbe2read-onlycurrentProbe 2 temperature in 1/100 degree Fahrenheit.
1.3.6.1.4.1.30932.1.1.3.9Nodehumidity
1.3.6.1.4.1.30932.1.1.3.9.1ScalarhumidityProbe1read-onlycurrentProbe 1 humidity in 1/100 %.
1.3.6.1.4.1.30932.1.1.3.9.2ScalarhumidityProbe2read-onlycurrentProbe 2 humidity in 1/100 %.
1.3.6.1.4.1.30932.1.1.3.10Nodealarms
1.3.6.1.4.1.30932.1.1.3.10.1ScalaralarmsMaxMapread-onlycurrentMax threshold alarmed state bitmap: bit0=currA, bit1=currB, bit2=currC ... bit6=voltA, bit7=voltB, bit8=voltC ... bit12=temperature1, bit13=temperature2, bit14…
1.3.6.1.4.1.30932.1.1.3.10.2ScalaralarmsMinMapread-onlycurrentMin threshold alarmed state bitmap: bit0=currA, bit1=currB, bit2=currC ... bit6=voltA, bit7=voltB, bit8=voltC ... bit12=temperature1, bit13=temperature2, bit14…
1.3.6.1.4.1.30932.1.1.3.10.3ScalaralarmsWarnHiMapread-onlycurrentHigh threshold warning state bitmap: bit0=currA, bit1=currB, bit2=currC ... bit6=voltA, bit7=voltB, bit8=voltC ... bit12=temperature1, bit13=temperature2, bit1…
1.3.6.1.4.1.30932.1.1.3.10.4ScalaralarmsWarnLoMapread-onlycurrentLow threshold warning state bitmap: bit0=currA, bit1=currB, bit2=currC ... bit6=voltA, bit7=voltB, bit8=voltC ... bit12=temperature1, bit13=temperature2, bit14…
1.3.6.1.4.1.30932.1.1.3.10.5Scalarrecep1To32AlarmsMaxMapread-onlycurrentMax threshold alarmed receptacle state bitmap: bit0=recep1, bit1=recep2, ... bit31=recep32
1.3.6.1.4.1.30932.1.1.3.10.7Scalarrecep1To32AlarmsMinMapread-onlycurrentMin threshold alarmed receptacle state bitmap: bit0=recep1, bit1=recep2, ... bit31=recep32
1.3.6.1.4.1.30932.1.1.3.10.9Scalarrecep1To32WarnHiMapread-onlycurrentHigh threshold warning receptacle state bitmap: bit0=recep1, bit1=recep2, ... bit31=recep32
1.3.6.1.4.1.30932.1.1.3.10.11Scalarrecep1To32WarnLoMapread-onlycurrentLow threshold warning receptacle state bitmap: bit0=recep1, bit1=recep2, ... bit31=recep32
1.3.6.1.4.1.30932.1.1.3.11Nodemenergy
1.3.6.1.4.1.30932.1.1.3.11.1Scalarenergyxy1sread-onlycurrentXY1 branch energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.11.2Scalarenergyyz1sread-onlycurrentYZ1 branch energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.11.3Scalarenergyzx1sread-onlycurrentZX1 branch energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.11.4Scalarenergyxy2sread-onlycurrentXY2 branch energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.11.5Scalarenergyyz2sread-onlycurrentYZ2 branch energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.11.6Scalarenergyzx2sread-onlycurrentZX2 branch energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12NodereceptacleEnergy
1.3.6.1.4.1.30932.1.1.3.12.1ScalarreceptacleEnergyoutlet1sread-onlycurrentOutlet1 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.2ScalarreceptacleEnergyoutlet2sread-onlycurrentOutlet2 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.3ScalarreceptacleEnergyoutlet3sread-onlycurrentOutlet3 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.4ScalarreceptacleEnergyoutlet4sread-onlycurrentOutlet4 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.5ScalarreceptacleEnergyoutlet5sread-onlycurrentOutlet5 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.6ScalarreceptacleEnergyoutlet6sread-onlycurrentOutlet6 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.7ScalarreceptacleEnergyoutlet7sread-onlycurrentOutlet7 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.8ScalarreceptacleEnergyoutlet8sread-onlycurrentOutlet8 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.9ScalarreceptacleEnergyoutlet9sread-onlycurrentOutlet9 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.10ScalarreceptacleEnergyoutlet10sread-onlycurrentOutlet10 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.11ScalarreceptacleEnergyoutlet11sread-onlycurrentOutlet11 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.12ScalarreceptacleEnergyoutlet12sread-onlycurrentOutlet12 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.13ScalarreceptacleEnergyoutlet13sread-onlycurrentOutlet13 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.14ScalarreceptacleEnergyoutlet14sread-onlycurrentOutlet14 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.15ScalarreceptacleEnergyoutlet15sread-onlycurrentOutlet15 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.16ScalarreceptacleEnergyoutlet16sread-onlycurrentOutlet16 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.17ScalarreceptacleEnergyoutlet17sread-onlycurrentOutlet17 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.18ScalarreceptacleEnergyoutlet18sread-onlycurrentOutlet18 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.19ScalarreceptacleEnergyoutlet19sread-onlycurrentOutlet19 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.20ScalarreceptacleEnergyoutlet20sread-onlycurrentOutlet20 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.21ScalarreceptacleEnergyoutlet21sread-onlycurrentOutlet21 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.22ScalarreceptacleEnergyoutlet22sread-onlycurrentOutlet22 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.23ScalarreceptacleEnergyoutlet23sread-onlycurrentOutlet23 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.12.24ScalarreceptacleEnergyoutlet24sread-onlycurrentOutlet24 receptacle energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.1.3.13Nodemline
1.3.6.1.4.1.30932.1.1.3.13.1Scalarline1currread-onlycurrentLine 1 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.13.2Scalarline2currread-onlycurrentLine 2 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.3.13.3Scalarline3currread-onlycurrentLine 3 current draw in 1/100 Amps.
1.3.6.1.4.1.30932.1.1.4Nodecontrol
1.3.6.1.4.1.30932.1.1.4.1NodecreceptacleControl
1.3.6.1.4.1.30932.1.1.4.1.1Scalaroutlet1ONOFFread-writecurrentTurn ON or OFF power to Outlet1, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.2Scalaroutlet2ONOFFread-writecurrentTurn ON or OFF power to Outlet2, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.3Scalaroutlet3ONOFFread-writecurrentTurn ON or OFF power to Outlet3, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.4Scalaroutlet4ONOFFread-writecurrentTurn ON or OFF power to Outlet4, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.5Scalaroutlet5ONOFFread-writecurrentTurn ON or OFF power to Outlet5, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.6Scalaroutlet6ONOFFread-writecurrentTurn ON or OFF power to Outlet6, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.7Scalaroutlet7ONOFFread-writecurrentTurn ON or OFF power to Outlet7, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.8Scalaroutlet8ONOFFread-writecurrentTurn ON or OFF power to Outlet8, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.9Scalaroutlet9ONOFFread-writecurrentTurn ON or OFF power to Outlet9, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.10Scalaroutlet10ONOFFread-writecurrentTurn ON or OFF power to Outlet10, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.11Scalaroutlet11ONOFFread-writecurrentTurn ON or OFF power to Outlet11, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.12Scalaroutlet12ONOFFread-writecurrentTurn ON or OFF power to Outlet12, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.13Scalaroutlet13ONOFFread-writecurrentTurn ON or OFF power to Outlet13, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.14Scalaroutlet14ONOFFread-writecurrentTurn ON or OFF power to Outlet14, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.15Scalaroutlet15ONOFFread-writecurrentTurn ON or OFF power to Outlet15, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.16Scalaroutlet16ONOFFread-writecurrentTurn ON or OFF power to Outlet16, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.17Scalaroutlet17ONOFFread-writecurrentTurn ON or OFF power to Outlet17, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.18Scalaroutlet18ONOFFread-writecurrentTurn ON or OFF power to Outlet18, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.19Scalaroutlet19ONOFFread-writecurrentTurn ON or OFF power to Outlet19, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.20Scalaroutlet20ONOFFread-writecurrentTurn ON or OFF power to Outlet20, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.21Scalaroutlet21ONOFFread-writecurrentTurn ON or OFF power to Outlet21, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.22Scalaroutlet22ONOFFread-writecurrentTurn ON or OFF power to Outlet22, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.23Scalaroutlet23ONOFFread-writecurrentTurn ON or OFF power to Outlet23, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.1.24Scalaroutlet24ONOFFread-writecurrentTurn ON or OFF power to Outlet24, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.4.2NodereceptacleReset
1.3.6.1.4.1.30932.1.1.4.2.1Scalaroutlet1Resetread-writecurrentReset power to Outlet1, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.2Scalaroutlet2Resetread-writecurrentReset power to Outlet2, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.3Scalaroutlet3Resetread-writecurrentReset power to Outlet3, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.4Scalaroutlet4Resetread-writecurrentReset power to Outlet4, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.5Scalaroutlet5Resetread-writecurrentReset power to Outlet5, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.6Scalaroutlet6Resetread-writecurrentReset power to Outlet6, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.7Scalaroutlet7Resetread-writecurrentReset power to Outlet7, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.8Scalaroutlet8Resetread-writecurrentReset power to Outlet8, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.9Scalaroutlet9Resetread-writecurrentReset power to Outlet9, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.10Scalaroutlet10Resetread-writecurrentReset power to Outlet10, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.11Scalaroutlet11Resetread-writecurrentReset power to Outlet11, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.12Scalaroutlet12Resetread-writecurrentReset power to Outlet12, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.13Scalaroutlet13Resetread-writecurrentReset power to Outlet13, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.14Scalaroutlet14Resetread-writecurrentReset power to Outlet14, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.15Scalaroutlet15Resetread-writecurrentReset power to Outlet15, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.16Scalaroutlet16Resetread-writecurrentReset power to Outlet16, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.17Scalaroutlet17Resetread-writecurrentReset power to Outlet17, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.18Scalaroutlet18Resetread-writecurrentReset power to Outlet18, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.19Scalaroutlet19Resetread-writecurrentReset power to Outlet19, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.20Scalaroutlet20Resetread-writecurrentReset power to Outlet20, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.21Scalaroutlet21Resetread-writecurrentReset power to Outlet21, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.22Scalaroutlet22Resetread-writecurrentReset power to Outlet22, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.23Scalaroutlet23Resetread-writecurrentReset power to Outlet23, 1=reset.
1.3.6.1.4.1.30932.1.1.4.2.24Scalaroutlet24Resetread-writecurrentReset power to Outlet24, 1=reset.
1.3.6.1.4.1.30932.1.1.4.3ScalarreceptacleCtrlMapread-onlycurrentMap of receptacle status in ascending order, 1=ON, 0=OFF.
1.3.6.1.4.1.30932.1.1.5Nodechained
1.3.6.1.4.1.30932.1.1.5.1ScalarpduCountread-onlycurrentCount of number of PDUs in the chain.
1.3.6.1.4.1.30932.1.1.5.2ScalarpduMapread-onlycurrentTable map of PDU IDs in the chain, each ID consists of 4 bytes.
1.3.6.1.4.1.30932.1.1.5.3ScalarpduSelectread-writecurrentSelects the PDUs in the chain for access.
1.3.6.1.4.1.30932.1.1.5.4ScalarpduNamelistread-onlycurrentList of PDU Names in the chain link, delimited by '|' and in matching order with pduMap.
1.3.6.1.4.1.30932.1.1.6NodecpiTraps
1.3.6.1.4.1.30932.1.1.6.0NodecpiSpecific
1.3.6.1.4.1.30932.1.1.6.0.1NotificationmaxCurrentxy1currentTrap is sent when current in XY1 exceeds set limit.
1.3.6.1.4.1.30932.1.1.6.0.2NotificationmaxCurrentyz1currentTrap is sent when current in YZ1 exceeds set limit.
1.3.6.1.4.1.30932.1.1.6.0.3NotificationmaxCurrentzx1currentTrap is sent when current in ZX1 exceeds set limit.
1.3.6.1.4.1.30932.1.1.6.0.4NotificationmaxCurrentxy2currentTrap is sent when current in XY2 exceeds set limit.
1.3.6.1.4.1.30932.1.1.6.0.5NotificationmaxCurrentyz2currentTrap is sent when current in YZ2 exceeds set limit.
1.3.6.1.4.1.30932.1.1.6.0.6NotificationmaxCurrentzx2currentTrap is sent when current in ZX2 exceeds set limit.
1.3.6.1.4.1.30932.1.1.6.0.7NotificationminCurrentxy1currentTrap is sent when current in XY1 drops below set limit.
1.3.6.1.4.1.30932.1.1.6.0.8NotificationminCurrentyz1currentTrap is sent when current in YZ1 drops below set limit.
1.3.6.1.4.1.30932.1.1.6.0.9NotificationminCurrentzx1currentTrap is sent when current in ZX1 drops below set limit.
1.3.6.1.4.1.30932.1.1.6.0.10NotificationminCurrentxy2currentTrap is sent when current in XY2 drops below set limit.
1.3.6.1.4.1.30932.1.1.6.0.11NotificationminCurrentyz2currentTrap is sent when current in YZ2 drops below set limit.
1.3.6.1.4.1.30932.1.1.6.0.12NotificationminCurrentzx2currentTrap is sent when current in ZX2 drops below set limit.
1.3.6.1.4.1.30932.1.1.6.0.13NotificationmaxVoltxy1currentTrap is sent when voltage in XY1 exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.14NotificationmaxVoltyz1currentTrap is sent when voltage in YZ1 exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.15NotificationmaxVoltzx1currentTrap is sent when voltage in ZX1 exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.16NotificationmaxVoltxy2currentTrap is sent when voltage in XY2 exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.17NotificationmaxVoltyz2currentTrap is sent when voltage in YZ2 exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.18NotificationmaxVoltzx2currentTrap is sent when voltage in ZX2 exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.19NotificationminVoltxy1currentTrap is sent when voltage in XY1 drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.20NotificationminVoltyz1currentTrap is sent when voltage in YZ1 drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.21NotificationminVoltzx1currentTrap is sent when voltage in ZX1 drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.22NotificationminVoltxy2currentTrap is sent when voltage in XY2 drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.23NotificationminVoltyz2currentTrap is sent when voltage in YZ2 drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.24NotificationminVoltzx2currentTrap is sent when voltage in ZX2 drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.25NotificationmaxTemperature1currentTrap is sent when temperature exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.26NotificationmaxTemperature2currentTrap is sent when temperature exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.27NotificationminTemperature1currentTrap is sent when temperature drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.28NotificationminTemperature2currentTrap is sent when temperature drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.29NotificationmaxHumidity1currentTrap is sent when humidity exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.30NotificationmaxHumidity2currentTrap is sent when humidity exceeds high limit.
1.3.6.1.4.1.30932.1.1.6.0.31NotificationminHumidity1currentTrap is sent when humidity drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.32NotificationminHumidity2currentTrap is sent when humidity drops below low limit.
1.3.6.1.4.1.30932.1.1.6.0.33NotificationchangeLogcurrentTrap is sent when changes in current exceed the amount set in LOGDIFFERENCE.
1.3.6.1.4.1.30932.1.1.6.0.34NotificationdataLogcurrentTrap is sent when the data logging interval time is reached
1.3.6.1.4.1.30932.1.1.6.0.35NotificationalarmChangecurrentTrap is sent when all alarms have been resolved/cleared
1.3.6.1.4.1.30932.1.2NodecpiMIBConformance
1.3.6.1.4.1.30932.1.2.1NodecpiMIBCompliances
1.3.6.1.4.1.30932.1.2.1.1CompliancecpiMIBComplianceRev1currentThe compliance statement for this MIB.
1.3.6.1.4.1.30932.1.2.2NodecpiMIBGroups
1.3.6.1.4.1.30932.1.2.2.1GroupcpiMIBGroupsObjectscurrentA collection of objects for managing the PDU.
1.3.6.1.4.1.30932.1.2.2.2GroupcpiMIBGroupNotificationscurrentA collection of notifications supported by PDU.
1.3.6.1.4.1.30932.1.10Nodeunity
1.3.6.1.4.1.30932.1.10.1Nodeeconnect
1.3.6.1.4.1.30932.1.10.1.2Nodesysteminfo
1.3.6.1.4.1.30932.1.10.1.2.1ScalarcpiPduTableCountread-onlycurrentGet the number of PDUs being monitored by this PDU. This is the number of entries in the cpiPduTable.
1.3.6.1.4.1.30932.1.10.1.2.10TablecpiPduTablenot-accessiblecurrentThis table contains a list of PDU entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of PDUs being mo…
1.3.6.1.4.1.30932.1.10.1.2.10.1RowcpiPduEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduTable'. Each column represents an attribute of a PDU. This table is indexed by the PDU MAC that is…
1.3.6.1.4.1.30932.1.10.1.2.10.1.1ColumncpiPduMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.2ColumncpiPduModelread-onlycurrentGet the model number of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.3ColumncpiPduNameread-writecurrentSet or get the user assigned name of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.4ColumncpiPduDescriptionread-writecurrentSet or get the user assigned description of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.5ColumncpiPduHasBranchMonitorread-onlycurrentAn indicator if the PDU supports monitoring voltage, and current on branches in the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.6ColumncpiPduHasOutletMonitorread-onlycurrentAn indicator if the PDU supports monitoring current on the individual outlets in the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.7ColumncpiPduHasOutletControlread-onlycurrentAn indicator if the PDU supports control (turn on/off) individual outlets in the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.8ColumncpiPduNumberBranchesread-onlycurrentGet the number of branches (breakers) in the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.9ColumncpiPduNumberOutletsread-onlycurrentGet the number of outlets in the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.10ColumncpiPduOutOfServiceread-writecurrentSet or get whether the PDU is in-service.
1.3.6.1.4.1.30932.1.10.1.2.10.1.11ColumncpiPduVersionread-onlycurrentGet the firmware version number of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.12ColumncpiPduUpgraderead-onlycurrentAn indicator if the PDU firmware is being upgraded.
1.3.6.1.4.1.30932.1.10.1.2.10.1.13ColumncpiPduChainRoleread-writecurrentGet the role of the PDU in a daisy chain.
1.3.6.1.4.1.30932.1.10.1.2.10.1.14ColumncpiPduIpread-onlycurrentGet IP address of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.15ColumncpiPduIpv6read-onlycurrentGet the IPv6 address of the PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.16ColumncpiPduTotalPowerread-onlycurrentGet the power in volt-amps for the entire PDU.
1.3.6.1.4.1.30932.1.10.1.2.10.1.17ColumncpiPduCabinetIdread-onlycurrentGet/set the name of the cabinet the PDU is in.
1.3.6.1.4.1.30932.1.10.1.2.10.1.18ColumncpiPduSerialNumread-onlycurrentGet the serial number of the PDU.
1.3.6.1.4.1.30932.1.10.1.3Nodebranch
1.3.6.1.4.1.30932.1.10.1.3.1ScalarcpiLineTableCountread-onlycurrentGet the number of PDU input lines being monitored by this PDU. This is the number of entries in the cpiLineTable and accounts for all input lines in a daisy ch…
1.3.6.1.4.1.30932.1.10.1.3.10TablecpiPduLineTablenot-accessiblecurrentThis table contains a list of PDU line entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of PDUs bei…
1.3.6.1.4.1.30932.1.10.1.3.10.1RowcpiPduLineEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduLineTable'. Each column represents an attribute of a PDU. This table is indexed by the PDU Line id…
1.3.6.1.4.1.30932.1.10.1.3.10.1.1ColumncpiPduLineMacread-onlycurrentGet the MAC address of the PDU that owns the input line.
1.3.6.1.4.1.30932.1.10.1.3.10.1.2ColumncpiPduLineIdread-onlycurrentGet the ID of the input line on the PDU.
1.3.6.1.4.1.30932.1.10.1.3.10.1.3ColumncpiPduLineCurrentread-onlycurrentGet current draw in 1/100 amp of the line on the PDU. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.100ScalarcpiBranchTableCountread-onlycurrentGet the number of PDU branches being monitored by this PDU. This is the number of entries in the cpiPduBranchTable.
1.3.6.1.4.1.30932.1.10.1.3.110TablecpiPduBranchTablenot-accessiblecurrentThis table contains a list of PDU branch entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of PDUs b…
1.3.6.1.4.1.30932.1.10.1.3.110.1RowcpiPduBranchEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduBranchTable'. Each column represents an attribute of a PDU. This table is indexed by the PDU Line …
1.3.6.1.4.1.30932.1.10.1.3.110.1.1ColumncpiPduBranchMacread-onlycurrentGet the MAC address of the PDU that owns the branch.
1.3.6.1.4.1.30932.1.10.1.3.110.1.2ColumncpiPduBranchIdread-onlycurrentGet the ID of the branch on the owning PDU.
1.3.6.1.4.1.30932.1.10.1.3.110.1.3ColumncpiPduBranchCurrentread-onlycurrentGet the current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.110.1.4ColumncpiPduBranchMaxCurrentread-onlycurrentGet the maximum current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.110.1.5ColumncpiPduBranchVoltageread-onlycurrentGet the voltage in 1/10 volts of the branch on the PDU. Convert the value by dividing by 10.
1.3.6.1.4.1.30932.1.10.1.3.110.1.6ColumncpiPduBranchPowerread-onlycurrentGet the power in volt-amps for the branch.
1.3.6.1.4.1.30932.1.10.1.3.110.1.7ColumncpiPduBranchPowerFactorread-onlycurrentGet the power factor for the branch.
1.3.6.1.4.1.30932.1.10.1.3.110.1.8ColumncpiPduBranchStatusread-onlycurrentGet the alarm status of the branch.
1.3.6.1.4.1.30932.1.10.1.3.110.1.9ColumncpiPduBranchEnergyread-onlycurrentGet the branch energy accumulated in decaVA-secs, divide by 360 to obtain VA-hr.
1.3.6.1.4.1.30932.1.10.1.3.210TablecpiPduBranchAlertTablenot-accessiblecurrentThis table contains a list of PDU branch alert entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of …
1.3.6.1.4.1.30932.1.10.1.3.210.1RowcpiPduBranchAlertEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduBranchAlertTable'. Each column represents an alert attribute of a PDU. This table is indexed by th…
1.3.6.1.4.1.30932.1.10.1.3.210.1.1ColumncpiPduBranchAlertMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.3.210.1.2ColumncpiPduBranchAlertBranchIdread-onlycurrentGet the branch ID on the PDU.
1.3.6.1.4.1.30932.1.10.1.3.210.1.3ColumncpiPduBranchAlertWarnLoCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU that triggers a warning condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.210.1.4ColumncpiPduBranchAlertWarnHiCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU that triggers a warning condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.210.1.5ColumncpiPduBranchAlertLoCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU that triggers an alarm condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.210.1.6ColumncpiPduBranchAlertHiCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU, that triggers an alarm condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.210.1.7ColumncpiPduBranchAlertCriticalCurrentread-writecurrentSet or get the critical current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.3.210.1.8ColumncpiPduBranchAlertWarnLoVoltread-writecurrentSet or get the minimum voltage that the branch can reach up to in 1/10th volts, 0=ignore. Convert the value by dividing by 10.
1.3.6.1.4.1.30932.1.10.1.3.210.1.9ColumncpiPduBranchAlertWarnHiVoltread-writecurrentSet or get the maximum voltage that the branch can reach up to in 1/10th volts, 0=ignore. Convert the value by dividing by 10.
1.3.6.1.4.1.30932.1.10.1.3.210.1.10ColumncpiPduBranchAlertLoVoltread-writecurrentSet or get the minimum voltage that the branch can reach up to in 1/10th volts, 0=ignore. Convert the value by dividing by 10.
1.3.6.1.4.1.30932.1.10.1.3.210.1.11ColumncpiPduBranchAlertHiVoltread-writecurrentSet or get the maximum voltage that the branch can reach up to in 1/10th volts, 0=ignore. Convert the value by dividing by 10.
1.3.6.1.4.1.30932.1.10.1.3.210.1.12ColumncpiPduBranchAlertIndexread-onlycurrentIndex for branch aler
1.3.6.1.4.1.30932.1.10.1.4Nodeoutlet
1.3.6.1.4.1.30932.1.10.1.4.1ScalarcpiOutletTableCountread-onlycurrentGet the number of PDU outlets being monitored by this PDU. This is the number of entries in the cpiPduOutletTable.
1.3.6.1.4.1.30932.1.10.1.4.10TablecpiPduOutletTablenot-accessiblecurrentThis table contains a list of PDU outlet entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of PDUs b…
1.3.6.1.4.1.30932.1.10.1.4.10.1RowcpiPduOutletEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduOutletTable'. Each column represents an outlet of a PDU. This table is indexed by the PDU Outlet i…
1.3.6.1.4.1.30932.1.10.1.4.10.1.1ColumncpiPduOutletMacread-onlycurrentGet the MAC address of the source PDU.
1.3.6.1.4.1.30932.1.10.1.4.10.1.2ColumncpiPduOutletIdread-onlycurrentGet the ID of the outlet on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.10.1.3ColumncpiPduOutletBranchIdread-onlycurrentGet the ID of the branch the outlet is associated with on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.10.1.4ColumncpiPduOutletNameread-writecurrentSet or get the user supplied name of the outlet on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.10.1.5ColumncpiPduOutletDescriptionread-writecurrentSet or get the user supplied description of the outlet on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.10.1.6ColumncpiPduOutletCurrentread-onlycurrentGet the current draw in 1/100 amp of the outlet on the PDU. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.4.10.1.7ColumncpiPduOutletVoltageread-onlycurrentGet the voltage in 1/10 volts of the outlet on the PDU. Convert the value by dividing by 10.
1.3.6.1.4.1.30932.1.10.1.4.10.1.8ColumncpiPduOutletPowerread-onlycurrentThe power in Volt-Amps of the outlet on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.10.1.9ColumncpiPduOutletStatusread-onlycurrentGet the alarm status of the outlet.
1.3.6.1.4.1.30932.1.10.1.4.10.1.10ColumncpiPduOutletEnergyread-onlycurrentGet the outlet energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.
1.3.6.1.4.1.30932.1.10.1.4.10.1.11ColumncpiPduOutletControlread-writecurrentSet or get power control to the outlet.
1.3.6.1.4.1.30932.1.10.1.4.10.1.12ColumncpiPduOutletResetread-writecurrentSet or get reset power to the outlet.
1.3.6.1.4.1.30932.1.10.1.4.210TablecpiPduOutletConfigTablenot-accessiblecurrentThis table contains a list of PDU outlet configuration entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the nu…
1.3.6.1.4.1.30932.1.10.1.4.210.1RowcpiPduOutletConfigEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduOutletConfigTable'. Each column represents an configurable attribute of an outlet in the PDU. This…
1.3.6.1.4.1.30932.1.10.1.4.210.1.1ColumncpiPduOutletConfigMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.4.210.1.2ColumncpiPduOutletConfigOutletIdread-onlycurrentGet the ID of the outlet on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.210.1.3ColumncpiPduOutletConfigOnDelayread-writecurrentSet or get the outlet power-on delay in seconds.
1.3.6.1.4.1.30932.1.10.1.4.210.1.4ColumncpiPduOutletConfigResetDelayread-writecurrentSet or get the outlet reset delay in seconds.
1.3.6.1.4.1.30932.1.10.1.4.310TablecpiPduOutletAlertTablenot-accessiblecurrentThis table contains a list of PDU outlet alert entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of …
1.3.6.1.4.1.30932.1.10.1.4.310.1RowcpiPduOutletAlertEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduOutletAlertTable'. Each column represents an alert attribute of a PDU. This table is indexed by th…
1.3.6.1.4.1.30932.1.10.1.4.310.1.1ColumncpiPduOutletAlertMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.4.310.1.2ColumncpiPduOutletAlertOutletIdread-onlycurrentGet the outlet ID on the PDU.
1.3.6.1.4.1.30932.1.10.1.4.310.1.3ColumncpiPduOutletAlertWarnLoCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU that triggers a warning condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.4.310.1.4ColumncpiPduOutletAlertWarnHiCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU that triggers a warning condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.4.310.1.5ColumncpiPduOutletAlertLoCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU that triggers an alarm condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.4.310.1.6ColumncpiPduOutletAlertHiCurrentread-writecurrentSet or get the current draw in 1/100 amp of the branch on the PDU, that triggers an alarm condition. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.4.310.1.7ColumncpiPduOutletAlertCriticalCurrentread-writecurrentSet or get the critical current draw in 1/100 amp of the outlet on the PDU. Convert the value by dividing by 100.
1.3.6.1.4.1.30932.1.10.1.5Nodesensors
1.3.6.1.4.1.30932.1.10.1.5.1ScalarcpiPduSensorCountread-onlycurrentGet the number of PDU sensors being monitored by this PDU. This is the number of entries in the cpiPduSensorTable.
1.3.6.1.4.1.30932.1.10.1.5.5TablecpiPduProbeTablenot-accessiblecurrentThis table contains a list of PDU probes that are being monitored by the PDU. The table contains zero, one, or many rows, depending upon the number of PDUs bei…
1.3.6.1.4.1.30932.1.10.1.5.5.1RowcpiPduProbeEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduProbeTable'. Each column represents an attribute of a PDU probe. This table is indexed by the PDU …
1.3.6.1.4.1.30932.1.10.1.5.5.1.1ColumncpiPduProbeMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.5.5.1.2ColumncpiPduProbeIdread-onlycurrentGet the probe ID on the PDU.
1.3.6.1.4.1.30932.1.10.1.5.5.1.3ColumncpiPduProbeNameread-writecurrentSet or get the user defined name of the probe.
1.3.6.1.4.1.30932.1.10.1.5.10TablecpiPduSensorTablenot-accessiblecurrentThis table contains a list of PDU sensor entries that are being monitored by the PDU. The table contains zero, one, or many rows, depending upon the number of …
1.3.6.1.4.1.30932.1.10.1.5.10.1RowcpiPduSensorEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduSensorTable'. Each column represents an attribute of a PDU sensor. This table is indexed by the PD…
1.3.6.1.4.1.30932.1.10.1.5.10.1.1ColumncpiPduSensorMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.5.10.1.2ColumncpiPduSensorIdread-onlycurrentGet the sensor ID on the PDU.
1.3.6.1.4.1.30932.1.10.1.5.10.1.3ColumncpiPduSensorNameread-onlycurrentSet or get the user defined name of the sensor.
1.3.6.1.4.1.30932.1.10.1.5.10.1.4ColumncpiPduSensorTyperead-onlycurrentGet the type of sensor for the entry.
1.3.6.1.4.1.30932.1.10.1.5.10.1.5ColumncpiPduSensorValueread-onlycurrentGet the value of the sensor. For temperature the value is in degrees Fahrenheit and for humidity the value is percent humidity.
1.3.6.1.4.1.30932.1.10.1.5.110TablecpiPduSensorAlertTablenot-accessiblecurrentThis table contains a list of PDU sensor alert entries that are being monitored by the PDU. The table contains zero, one, or many rows, depending upon the numb…
1.3.6.1.4.1.30932.1.10.1.5.110.1RowcpiPduSensorAlertEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiPduSensorAlertTable'. Each column represents an attribute of a PDU sensor alert. This table is indexe…
1.3.6.1.4.1.30932.1.10.1.5.110.1.1ColumncpiPduSensorAlertMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.5.110.1.2ColumncpiPduSensorAlertSensorIdread-onlycurrentGet the id of the sensor.
1.3.6.1.4.1.30932.1.10.1.5.110.1.3ColumncpiPduSensorAlertWarnMinread-writecurrentSet or get the minimum warning value of the sensor.
1.3.6.1.4.1.30932.1.10.1.5.110.1.4ColumncpiPduSensorAlertWarnMaxread-writecurrentSet or get the maximum warning value of the sensor.
1.3.6.1.4.1.30932.1.10.1.5.110.1.5ColumncpiPduSensorAlertMinread-writecurrentSet or get the minimum alarm value of the sensor.
1.3.6.1.4.1.30932.1.10.1.5.110.1.6ColumncpiPduSensorAlertMaxread-writecurrentSet or get the maximum alarm value of the sensor.
1.3.6.1.4.1.30932.1.10.1.6Nodegroup
1.3.6.1.4.1.30932.1.10.1.6.1ScalarcpiPduGroupCountread-onlycurrentGet the number of supported groups by the PDU. Value from 0 to 16.
1.3.6.1.4.1.30932.1.10.1.6.2ScalarcpiPduGroupOutletCountread-onlycurrentGet the number of outlets in the Group Outlet Table.
1.3.6.1.4.1.30932.1.10.1.6.10TablecpiGroupTablenot-accessiblecurrentThis table contains a list of PDU group entries that are being monitored by the PDU. The table contains one, or many rows, depending upon the number of groups …
1.3.6.1.4.1.30932.1.10.1.6.10.1RowcpiGroupEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiGroupTable'. This table is indexed by the group identifier that is unique within the PDU.
1.3.6.1.4.1.30932.1.10.1.6.10.1.1ColumncpiGroupEntryIndexread-onlycurrentThis is the index that indicates the row of the 'cpiPduTable'.
1.3.6.1.4.1.30932.1.10.1.6.10.1.2ColumncpiGroupNameread-writecurrentName for GROUP 1 of receptacles.
1.3.6.1.4.1.30932.1.10.1.6.20TablecpiGroupOutletTablenot-accessiblecurrentThis table contains a list of PDU group entries. The table contains zero, one, or many rows, depending upon the number of groups that have been configured. Eac…
1.3.6.1.4.1.30932.1.10.1.6.20.1RowcpiGroupOutletEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiGroupTable'. This table is indexed by the group identifier that is unique within the PDU.
1.3.6.1.4.1.30932.1.10.1.6.20.1.1ColumncpiGroupOutletEntryIndexread-onlycurrentThis is the index that indicates the row of the 'cpiGroupOutletTable'.
1.3.6.1.4.1.30932.1.10.1.6.20.1.2ColumncpiGroupOutletGroupIDread-onlycurrentName for GROUP 1 of receptacles.
1.3.6.1.4.1.30932.1.10.1.6.20.1.3ColumncpiGroupOutletPDUMacread-writecurrentMAC of PDU the outlet is on.
1.3.6.1.4.1.30932.1.10.1.6.20.1.4ColumncpiGroupOutletOutletIdread-writecurrentThe ID of the outlet on the PDU.
1.3.6.1.4.1.30932.1.10.1.7NodeeasData
1.3.6.1.4.1.30932.1.10.1.7.1ScalarcpiEasCountread-onlycurrentGet the number of locks connected to the PDU. This includes the PDUs on the daisy chain.
1.3.6.1.4.1.30932.1.10.1.7.90TablecpiEasConfigTablenot-accessiblecurrentThis table contains a list of electronic locks that are connected to the PDU and allows for the configuration of the various settings associated with the EAS (…
1.3.6.1.4.1.30932.1.10.1.7.90.1RowcpiEasConfigEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiEasTable'. Each column represents an attribute of a PDU lock. This table is indexed by the PDU identi…
1.3.6.1.4.1.30932.1.10.1.7.90.1.1ColumncpiEasConfigLockMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.7.90.1.2ColumncpiEasConfigEnabledread-onlycurrentIndicates whether the Electronic Access System (EAS) is available on the PDU.
1.3.6.1.4.1.30932.1.10.1.7.90.1.3ColumncpiEasFrontLockEnabledread-writecurrentEnables the front lock on the EAS.
1.3.6.1.4.1.30932.1.10.1.7.90.1.4ColumncpiEasRearLockEnabledread-writecurrentEnables the rear lock on the EAS.
1.3.6.1.4.1.30932.1.10.1.7.90.1.5ColumncpiEasLockHoldOpenTimeread-writecurrentThe length of time in seconds to hold open the lock after a successful card scan.
1.3.6.1.4.1.30932.1.10.1.7.90.1.6ColumncpiEasDoorOpenAlarmTimeread-writecurrentThe length of time in minutes before alerting that the door is open.
1.3.6.1.4.1.30932.1.10.1.7.100TablecpiEasTablenot-accessiblecurrentThis table contains a list of electronic locks that are connected to the PDU The table contains zero, one, or many rows, depending upon the number of PDUs bein…
1.3.6.1.4.1.30932.1.10.1.7.100.1RowcpiEasEntrynot-accessiblecurrentThis entry defines the columns to be populated in the 'cpiEasTable'. Each column represents an attribute of a PDU lock. This table is indexed by the PDU identi…
1.3.6.1.4.1.30932.1.10.1.7.100.1.1ColumncpiPduLockMacread-onlycurrentGet the MAC address of the PDU.
1.3.6.1.4.1.30932.1.10.1.7.100.1.2ColumncpiPduLockIdread-onlycurrentGet the lock ID on the PDU.
1.3.6.1.4.1.30932.1.10.1.7.100.1.3ColumncpiPduEasStatusread-onlycurrentIndicates if the Electronic Access Control system is ready, inactive, or in an error state. If the status is Inactive, then the lock is not enabled on the PDU.…
1.3.6.1.4.1.30932.1.10.1.7.100.1.4ColumncpiPduDoorStatusread-onlycurrentIndicates if the door sensor is closed or open.
1.3.6.1.4.1.30932.1.10.1.7.100.1.5ColumncpiPduLockStatusread-onlycurrentIndicates if the lock is closed or open.
1.3.6.1.4.1.30932.1.10.1.7.100.1.6ColumncpiPduForceStatusread-onlycurrentIndicates if the cabinet was forced open by a command from the webUI or SNMP interfaces.
1.3.6.1.4.1.30932.1.10.1.7.100.1.7ColumncpiPduTamperStatusread-onlycurrentIndicates if the cabinet is currently unlocked/opened without an authorization scan.
1.3.6.1.4.1.30932.1.10.1.7.100.1.8ColumncpiEasErrorread-onlycurrentGets the error code associated for the electronic lock system. The possible error codes are: 196608 (0x00030000 ) - No error, the lock is working and ready. 16…
1.3.6.1.4.1.30932.1.10.1.7.100.1.9ColumncpiEasLockVerread-onlycurrentGets the version of the electronic lock control.
1.3.6.1.4.1.30932.1.10.1.7.100.1.10ColumncpiEasLockSerialNumberread-onlycurrentGet the serial number of the electronic lock control.
1.3.6.1.4.1.30932.1.10.1.7.100.1.11ColumncpiPduLockCtrlread-writecurrentTells the system to open the locks on the cabinet.
1.3.6.1.4.1.30932.1.10.1.500Nodetraps
1.3.6.1.4.1.30932.1.10.1.500.0NodetrapInformation
1.3.6.1.4.1.30932.1.10.1.500.0.1ScalartrapInfoUserNamenot-accessiblecurrentThe user Id associated with the action.
1.3.6.1.4.1.30932.1.10.1.500.0.2ScalartrapInfoCardIdnot-accessiblecurrentThe card Id associated with the action.
1.3.6.1.4.1.30932.1.10.1.500.0.3ScalartrapInfoConfigNamenot-accessiblecurrentThe configuration value that was changed.
1.3.6.1.4.1.30932.1.10.1.500.0.4ScalartrapInfoInterfacenot-accessiblecurrentAn identifier for the affected interface.
1.3.6.1.4.1.30932.1.10.1.500.0.5ScalartrapInfoVarIdnot-accessiblecurrentAn identifier for the value that was changed.
1.3.6.1.4.1.30932.1.10.1.500.0.6ScalartrapInfoBootTypenot-accessiblecurrentIndicates that type of boot up occurring. A Cold boot is done from a complete power off. A Warm boot was not a loss in power, but just a reboot of the control …
1.3.6.1.4.1.30932.1.10.1.500.0.7ScalartrapInfoProgressnot-accessiblecurrentIndicates the percent complete of an operation.
1.3.6.1.4.1.30932.1.10.1.500.0.8ScalartrapInfoResultnot-accessiblecurrentIndicates the result of an operation.
1.3.6.1.4.1.30932.1.10.1.500.0.9ScalartrapInfoErrorCodenot-accessiblecurrentIndicates the error code of an operation. See the operation for details. Firmware Update Operation Error Codes: 151060481 - Error: Insufficient space available…
1.3.6.1.4.1.30932.1.10.1.500.0.10ScalartrapInfoGroupNamenot-accessiblecurrentThe user group Id associated with the action.
1.3.6.1.4.1.30932.1.10.1.500.1NodesystemNotifications
1.3.6.1.4.1.30932.1.10.1.500.1.1NotificationsystemConfigChangeAlertcurrentNotification that a configuration value was changed on the PDU.
1.3.6.1.4.1.30932.1.10.1.500.1.2NotificationsystemBootAlertcurrentNotification that a PDU is booting up.
1.3.6.1.4.1.30932.1.10.1.500.1.3NotificationsystemFWUpdateStartAlertcurrentNotification that a firmware update has been initiated.
1.3.6.1.4.1.30932.1.10.1.500.1.4NotificationsystemFWUpdateStatusAlertcurrentNotification that about the progress of the firmware update.
1.3.6.1.4.1.30932.1.10.1.500.1.5NotificationsystemFWUpdateCompleteAlertcurrentNotification that about the progress of the firmware update.
1.3.6.1.4.1.30932.1.10.1.500.1.6NotificationsystemSecureArrayFailoverAlertcurrentNotification that the SecureArray is being managed by the identified PDU.
1.3.6.1.4.1.30932.1.10.1.500.1.7NotificationsystemSecureArrayDisconnectAlertcurrentNotification that the specified PDU disconnected from the SecureArray.
1.3.6.1.4.1.30932.1.10.1.500.1.8NotificationsystemSecureArrayConnectAlertcurrentNotification that the specified PDU connected to the SecureArray.
1.3.6.1.4.1.30932.1.10.1.500.1.9NotificationsystemConfigCertAlertcurrentNotification that the HTTPS certificate was changed on the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2NodeuserNotifications
1.3.6.1.4.1.30932.1.10.1.500.2.1NotificationuserLoginAlertcurrentNotification that a user logged onto the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.2NotificationuserLoginFailAlertcurrentNotification that a user failed to log onto the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.3NotificationuserAddAlertcurrentNotification that a user was added to the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.4NotificationuserDeleteAlertcurrentNotification that a user was deleted from the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.5NotificationuserModifiedAlertcurrentNotification that a user was modified on the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.6NotificationuserGroupAddAlertcurrentNotification that a user group was added to the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.7NotificationuserGroupDeleteAlertcurrentNotification that a user group was deleted from the PDU.
1.3.6.1.4.1.30932.1.10.1.500.2.8NotificationuserGroupModifyAlertcurrentNotification that a user group was modified on the PDU.
1.3.6.1.4.1.30932.1.10.1.500.3NodeinletNotifications
1.3.6.1.4.1.30932.1.10.1.500.4NodebranchNotifications
1.3.6.1.4.1.30932.1.10.1.500.5NodeoutletNotifications
1.3.6.1.4.1.30932.1.10.1.500.5.1NotificationoutletStateChangeAlertcurrentThe outlet state has changed.
1.3.6.1.4.1.30932.1.10.1.500.6NodeenvironNotification
1.3.6.1.4.1.30932.1.10.1.500.6.1NotificationenvironMaxTempAlertcurrentThe temperature sensor reached the Maximum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.2NotificationenvironMinTempAlertcurrentThe temperature sensor reached the minimum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.3NotificationenvironMaxHumidAlertcurrentThe humidity sensor reached the maximum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.4NotificationenvironMinHumidAlertcurrentThe humidity sensor reached the maximum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.5NotificationenvironMaxWarnTempAlertcurrentThe temperature sensor reached the Maximum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.6NotificationenvironMinWarnTempAlertcurrentThe temperature sensor reached the minimum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.7NotificationenvironMaxWarnHumidAlertcurrentThe humidity sensor reached the maximum limit.
1.3.6.1.4.1.30932.1.10.1.500.6.8NotificationenvironMinWarnHumidAlertcurrentThe humidity sensor reached the maximum limit.
1.3.6.1.4.1.30932.1.10.1.500.7NodeeasNotification
1.3.6.1.4.1.30932.1.10.1.500.7.1NotificationeasScanPassAlertcurrentA card was scanned and the associated user was authenticated and authorized to access the cabinet.
1.3.6.1.4.1.30932.1.10.1.500.7.2NotificationeasScanFailAlertcurrentA card was scanned but was not authenticated or authorized to access the cabinet.
1.3.6.1.4.1.30932.1.10.1.500.7.3NotificationeasDoorOpenAlertcurrentNotification that a door was opened.
1.3.6.1.4.1.30932.1.10.1.500.7.4NotificationeasDoorCloseAlertcurrentNotification that a door was closed.
1.3.6.1.4.1.30932.1.10.1.500.7.5NotificationeasLockOpenAlertcurrentNotification that a lock was opened.
1.3.6.1.4.1.30932.1.10.1.500.7.6NotificationeasLockCloseAlertcurrentNotification that a lock was closed.
1.3.6.1.4.1.30932.1.10.1.500.7.7NotificationeasDoorExtOpenAlertcurrentNotification that a door was open for longer that the time set in cpiEasDoorOpenAlarmTime setting.
1.3.6.1.4.1.30932.1.10.1.500.7.8NotificationeasDoorExtOpenClearAlertcurrentNotification that a door was open for longer that the time set in cpiEasDoorOpenAlarmTime setting.
1.3.6.1.4.1.30932.1.10.1.500.7.9NotificationeasForceUnlockAlertcurrentNotification that a door was open for longer that the time set in cpiEasDoorOpenAlarmTime setting.
1.3.6.1.4.1.30932.1.10.1.600Nodemibconformance