MIB Viewer

CRI-SERVER-MIB

270 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.34Nodesun
1.3.6.1.4.1.34.0NodedomainChangeThis trap indicates the domain table has changed. The first two variables (platformName and confNumDomain) will always have an instance value of 0. The remaini…
1.3.6.1.4.1.34.1NodeeddControlThis trap indicates the action EDD should be taken. All variables for this trap are mandatory.
1.3.6.1.4.1.34.2NodeeddStateThis trap indicates the new state of the EDD. All variables for this trap are mandatory.
1.3.6.1.4.1.34.2Nodeproducts
1.3.6.1.4.1.34.2.1Nodegeneral
1.3.6.1.4.1.34.2.1.1Nodeplatform
1.3.6.1.4.1.34.2.1.1.1ScalarplatformTyperead-onlymandatoryThe platform type. Currently, only one platform is defined: Starfire. There is no plan to backport to CS6400 yet.
1.3.6.1.4.1.34.2.1.1.2ScalarplatformNameread-onlymandatoryThe name assigned to a physical machine.
1.3.6.1.4.1.34.2.1.1.3ScalarplatformAmbientTempread-onlymandatoryThe current ambient temperature of the platform. The temperature will be in Celsius.
1.3.6.1.4.1.34.2.1.1.4ScalarplatformResetread-writemandatoryThis member resets the platform.
1.3.6.1.4.1.34.2.1.1.5ScalarplatformInterconnectClockFreqread-onlymandatoryThis member is the current interconnect frequency of the platform. The unit is in Hz.
1.3.6.1.4.1.34.2.1.1.6ScalarplatformProcClockFreqread-onlymandatoryThis member is the current processor clock frequency of the platform. The unit is in Hz.
1.3.6.1.4.1.34.2.1.1.7ScalarplatformJtagClockFreqread-onlymandatoryThis member is the current JTAG clock frequency of the platform. The unit is in Hz. Note: this member is only measurable in the rev-3 control board. If this un…
1.3.6.1.4.1.34.2.1.1.8ScalarplatformTargetInterconnectClockFreqread-writemandatoryThis member is the targeted interconnect clock frequency. The unit is in Hz and the valid range is between 40,000,000 Hz and 120,000,000 Hz. The platformTarget…
1.3.6.1.4.1.34.2.1.1.9ScalarplatformTargetProcClockMultipleread-writemandatoryThis member is the targeted processor clock frequency expressed in terms of a specific factor of the system clock. Possible options are factor of 2 or 3. See p…
1.3.6.1.4.1.34.2.1.1.10ScalarplatformTargetJtagClockFreqread-onlymandatoryThis member is the targeted JTAG clock frequency. The unit is in Hz. See platformTargetSystemClockFreq for more detail.
1.3.6.1.4.1.34.2.1.1.11ScalarplatformMasterConBrdread-onlymandatoryThis member is the master control board number.
1.3.6.1.4.1.34.2.1.1.12ScalarplatformSysClkConBrdread-onlymandatoryThis member is the control board providing system clock to the platform.
1.3.6.1.4.1.34.2.1.2Nodeconf
1.3.6.1.4.1.34.2.1.2.1ScalarconfNumDomainread-onlymandatoryThe number of domain in the platform. Domains are created with command, domain_create. Domains are removed with command, domain_remove.
1.3.6.1.4.1.34.2.1.2.2ScalarconfNumSysBrdread-onlymandatoryThe number of system board in the platform. The max # system board in a Starfire system is 16.
1.3.6.1.4.1.34.2.1.2.3ScalarconfNumProcread-onlymandatoryThe number of processor in a system board. The max # processors in a Starfire system is 64.
1.3.6.1.4.1.34.2.1.2.4ScalarconfNumConBrdread-onlymandatoryThe number of control board in the system. The max # control board in a Starfire system is 2.
1.3.6.1.4.1.34.2.1.2.5ScalarconfNumCenterplaneread-onlymandatoryThe number of centerplane in the system. The max # centerplane half board in a Starfire system is 2.
1.3.6.1.4.1.34.2.1.2.6ScalarconfNumSuppBrdread-onlymandatoryThe number of centerplane support board in the system. The max # of centerplane support board in a Starfire system is 2.
1.3.6.1.4.1.34.2.1.2.7ScalarconfNumIoCabread-onlymandatoryThe number of IO cabinet connected to the system. The max # of IO cabinets that can be connected to a Starfire system is 3.
1.3.6.1.4.1.34.2.1.2.8ScalarconfNumFanTrayread-onlymandatoryThe number of fan tray in the system. The max # of fan trays that can be installed in a Starfire system is 16.
1.3.6.1.4.1.34.2.1.2.9ScalarconfNumBulkPowerread-onlymandatoryThe number of bulk power supply in the system. The max # of bulk power supply in a Starfire system is 8.
1.3.6.1.4.1.34.2.1.2.10ScalarconfNumSysBrdPowerread-onlymandatoryThe number of system board power supply in the system. The max # of system board power supply for a Starfire system is 16. In Starfire, system board power supp…
1.3.6.1.4.1.34.2.1.2.11ScalarconfSysBrdListread-onlymandatoryA string identifying the system boards that are present in the system. The format of the string is: xx-xx-.. where xx is the system board number and the delimi…
1.3.6.1.4.1.34.2.1.2.12ScalarconfProcListread-onlymandatoryA string identifying the processors that are present in the system. The format of the string is: bb.pp-bb.pp-... where bb is the system board number and pp is …
1.3.6.1.4.1.34.2.1.2.13ScalarconfConBrdListread-onlymandatoryA string identifying the control boards that are present in the system. The format of the string is: xx-xx-.. where xx is the control board number and dash is …
1.3.6.1.4.1.34.2.1.2.14ScalarconfCenterplaneListread-onlymandatoryA string identifying the centerplanes that are present in the system. The format of the string is: xx-xx-.. where xx is the centerplane number and dash is the …
1.3.6.1.4.1.34.2.1.2.15ScalarconfSuppBrdListread-onlymandatoryA string identifying the centerplane support boards that are present in the system. The format of the string is: xx-xx-... where xx is the centerplane support …
1.3.6.1.4.1.34.2.1.2.16ScalarconfIoCabListread-onlymandatoryA string identifying the IO cabinets that are connected to the system. The format of the string is: xx-xx-... where xx is the I/O cabinet number and dash is th…
1.3.6.1.4.1.34.2.1.2.17ScalarconfFanTrayListread-onlymandatoryA string identifying the fan trays that are present in the system. the format of the string is: xx-xx-... where xx is the fan tray number and dash is the delim…
1.3.6.1.4.1.34.2.1.2.18ScalarconfBulkPowerListread-onlymandatoryA string identifying the bulk power supplies that are present in the system. The format of the string is: x-x where x is the bulk power supply number and dash …
1.3.6.1.4.1.34.2.1.2.19ScalarconfSysBrdPowerListread-onlymandatoryA string identifying the system board power supplies that are present in the system. The format of the string: xx-xx-... where xx is the system board power sup…
1.3.6.1.4.1.34.2.1.2.20ScalarconfMaxProcPerSysBrdread-onlymandatoryThe maximum number of processor in a system board. There is a max of 4 processors in a Starfire system board.
1.3.6.1.4.1.34.2.1.2.21ScalarconfMaxFanPerTrayread-onlymandatoryThe maximum number of fan in a fan tray. There is a max of 2 fan in a Starfire fan tray.
1.3.6.1.4.1.34.2.1.2.22ScalarconfMaxLEDPerFanTrayread-onlymandatoryThe maximum number of LED in a fan tray. There is a max of 2 LEDs in a Starfire fan tray.
1.3.6.1.4.1.34.2.1.2.23ScalarconfMaxLEDPerBulkPowerread-onlymandatoryThe maximum number of LED in a bulk power supply. There is a max of 2 LEDs in a Starfire bulk power supply.
1.3.6.1.4.1.34.2.1.2.24ScalarconfMaxLEDPerSysBrdread-onlymandatoryThe maximum number of LED in a system board.
1.3.6.1.4.1.34.2.1.2.25ScalarconfMemAddrMapread-writemandatoryStarfire supports Shared Memory Domains. This requires the memory boards in the machine to have unique address. Because of this global requirement, Starfire hp…
1.3.6.1.4.1.34.2.1.3TabledomainTablenot-accessiblemandatoryThe domain table. The number of entries in the table is given by conf.confNumDomain.
1.3.6.1.4.1.34.2.1.3.1RowdomainEntrynot-accessiblemandatoryA domain table entry.
1.3.6.1.4.1.34.2.1.3.1.1ColumndomainIndexread-onlymandatoryA number assigned to a domain.
1.3.6.1.4.1.34.2.1.3.1.2ColumndomainNameread-onlymandatoryDomain name in ASCII format.
1.3.6.1.4.1.34.2.1.3.1.3ColumndomainNumSysBrdread-onlymandatoryThe number of system board assigned to this domain.
1.3.6.1.4.1.34.2.1.3.1.4ColumndomainSysBrdListread-onlymandatoryA list of system board entries belonging to this domain. The number of boards is given by domainNumSysBrd. The format of the string is: xx-xx where xx is the s…
1.3.6.1.4.1.34.2.1.3.1.5ColumndomainOSVersionread-onlymandatoryThe OS version for this domain.
1.3.6.1.4.1.34.2.1.3.1.6ColumndomainProcListread-onlymandatoryA list of processors belonging to this domain. The format of the string is in: ss.bb-ss.bb-... where ss is the system board number, bb is the processor number …
1.3.6.1.4.1.34.2.1.3.1.7ColumndomainBootProcread-writemandatoryThe boot processor number of this domain. If the value is -1, that means the domain is not configured/booted.
1.3.6.1.4.1.34.2.1.3.1.8ColumndomainInterruptVectorread-writemandatoryInterrupts to the host processor via JTAG requires 2 pieces of information: the UPA ID of the target CPU and the interrupt number assigned to the bootbus inter…
1.3.6.1.4.1.34.2.1.3.1.9ColumndomainSysBrdConfigread-onlymandatoryA list of configured system board entries belonging to this domain. The format of the string is: xx-xx where xx is the system board number and dash is the deli…
1.3.6.1.4.1.34.2.1.3.1.10ColumndomainProcConfigread-onlymandatoryPOST scans both blacklist and redlist files to determine which components should not be used to configure a domain. The content of the blacklist and redlist fi…
1.3.6.1.4.1.34.2.1.3.1.11ColumndomainABusConfigread-onlymandatorydomainAbusConfig describes the address bus configuration. Its format is a DisplayString in the format of xxS-xxS-... where xx is an address bus [0..3] and S is…
1.3.6.1.4.1.34.2.1.3.1.12ColumndomainDBusConfigread-onlymandatorydomainDbusConfig describes the data bus configuration. Its format is a DisplayString in the format of xxS-xxS where xx is a data bus [0..1] and S is a status c…
1.3.6.1.4.1.34.2.1.4TablesysBrdGenTablenot-accessiblemandatorySystem board table. The number host of entries in the table is represented by Conf.ConfNumSysBrd.
1.3.6.1.4.1.34.2.1.4.1RowsysBrdGenEntrynot-accessiblemandatoryA system board table entry.
1.3.6.1.4.1.34.2.1.4.1.1ColumnsysBrdGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.4.1.2ColumnsysBrdGenNumread-onlymandatoryA unique number assigned to a system board. Index begins with 1.
1.3.6.1.4.1.34.2.1.4.1.3ColumnsysBrdGenPowerread-onlymandatoryPower status of the system board. To control power to a system board, modify the sysBrdGenPowerControl.
1.3.6.1.4.1.34.2.1.4.1.4ColumnsysBrdGenNumProcread-onlymandatoryNumber of processor that are present in this system board.
1.3.6.1.4.1.34.2.1.4.1.5ColumnsysBrdGenProcListread-onlymandatoryA string containing the processors list that are present in this system board. The format of the string is: xx-xx where xx is the processor number within a sys…
1.3.6.1.4.1.34.2.1.4.1.6ColumnsysBrdGenResetread-writemandatoryThis member resets the system board.
1.3.6.1.4.1.34.2.1.4.1.7ColumnsysBrdGenPowerControlread-writemandatoryOn reading it returns the power status of this system board power supply. On writing, it turns on/off this system board power supply.
1.3.6.1.4.1.34.2.1.5TableprocStateGenTablenot-accessiblemandatoryA table of processor entries.
1.3.6.1.4.1.34.2.1.5.1RowprocStateGenEntrynot-accessiblemandatoryA processor state table entry.
1.3.6.1.4.1.34.2.1.5.1.1ColumnprocStateGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.5.1.2ColumnprocStateGenNumread-onlymandatoryA unique number assigned to each CPU.
1.3.6.1.4.1.34.2.1.5.1.3ColumnprocStateGenHeartbeatread-onlymandatoryA counter being updated by the kernel. This serves an as indicator that the kernel is alive and well.
1.3.6.1.4.1.34.2.1.5.1.4ColumnprocStateGenPgmSignatureread-onlymandatoryThis value represents the current program running on a processor. Only 4 programs are identified: POST, Download_helper, OBP, and the kernel.
1.3.6.1.4.1.34.2.1.5.1.5ColumnprocStateGenPgmStateread-onlymandatoryThis value represents the current state of the program running on a processor. #define SIGBST_NONE 0 /* no state */ #define SIGBST_RUN 1 /* running */ #define …
1.3.6.1.4.1.34.2.1.5.1.6ColumnprocStateGenPgmSubStateread-onlymandatoryThis value represents a finer detail of the current state of the program running on a processor. #define EXIT_NULL 0 #define EXIT_HALT 1 #define EXIT_ENVIRON 2…
1.3.6.1.4.1.34.2.1.5.1.7ColumnprocStateGenTempread-onlymandatoryThe processor temperature.
1.3.6.1.4.1.34.2.1.6TableprocCommGenTablenot-accessiblemandatoryA table of processor communication entries.
1.3.6.1.4.1.34.2.1.6.1RowprocCommGenEntrynot-accessiblemandatoryA processor communication table entry.
1.3.6.1.4.1.34.2.1.6.1.1ColumnprocCommGenIndexread-onlymandatoryA unique number assigned to each CPU.
1.3.6.1.4.1.34.2.1.6.1.2ColumnprocCommGenNumread-onlymandatoryA unique number assigned to each CPU.
1.3.6.1.4.1.34.2.1.6.1.3ColumnprocCommGenSspMboxLenread-writemandatoryThe length of SSP-to-Host mailbox. This mailbox is used to instruct the host to perform a specific command.
1.3.6.1.4.1.34.2.1.6.1.4ColumnprocCommGenSspMboxFlagread-writemandatoryThe flag of SSP-to-Host mailbox.
1.3.6.1.4.1.34.2.1.6.1.5ColumnprocCommGenSspMboxCmdread-writemandatoryThe command of SSP-to-Host mailbox.
1.3.6.1.4.1.34.2.1.6.1.6ColumnprocCommGenSspMboxDataread-writemandatoryThe data in the SSP-to-Host mailbox.
1.3.6.1.4.1.34.2.1.6.1.7ColumnprocCommGenHostMboxLenread-writemandatoryThe length of Host-to-SSP mailbox.
1.3.6.1.4.1.34.2.1.6.1.8ColumnprocCommGenHostMboxFlagread-writemandatoryThe flag of Host-to-SSP mailbox.
1.3.6.1.4.1.34.2.1.6.1.9ColumnprocCommGenHostMboxCmdread-writemandatoryThe command of Host-to-SSP mailbox.
1.3.6.1.4.1.34.2.1.6.1.10ColumnprocCommGenHostMboxDataread-writemandatoryThe data in the Host-to-SSP mailbox. This mailbox serves for communication between OBP running on the host and obp_helper running on the SSP.
1.3.6.1.4.1.34.2.1.6.1.11ColumnprocCommGenObpMboxLenread-writemandatoryThe length of Obp-to-SSP mailbox.
1.3.6.1.4.1.34.2.1.6.1.12ColumnprocCommGenObpMboxFlagread-writemandatoryThe flag of Obp-to-SSP mailbox.
1.3.6.1.4.1.34.2.1.6.1.13ColumnprocCommGenObpMboxCmdread-writemandatoryThe command of Obp-to-SSP mailbox. #define SSPC_MULTIPROC 0x0b0b0001 /* Request to release slave CPUs */ #define SSPC_GETTOD 0x0b0b0002 /* Get Unix time of day…
1.3.6.1.4.1.34.2.1.6.1.14ColumnprocCommGenObpMboxDataread-writemandatoryThe data in the Obp-to-SSP mailbox.
1.3.6.1.4.1.34.2.1.6.1.15ColumnprocCommGenCvcInputDataread-writemandatoryThe input buffer to cvc.
1.3.6.1.4.1.34.2.1.6.1.16ColumnprocCommGenCvcOutputDataread-writemandatoryThe output buffer to cvc.
1.3.6.1.4.1.34.2.1.7TablecbGenTablenot-accessiblemandatoryA table of general control board entries.
1.3.6.1.4.1.34.2.1.7.1RowcbGenEntrynot-accessiblemandatoryA general control board table entry.
1.3.6.1.4.1.34.2.1.7.1.1ColumncbGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.7.1.2ColumncbGenNumread-onlymandatoryA unique number assigned to a control board.
1.3.6.1.4.1.34.2.1.7.1.3ColumncbGenPowerread-onlymandatoryPower status of the control board.
1.3.6.1.4.1.34.2.1.7.1.4ColumncbGenPowerControlread-writemandatoryOn writing, it turns off this control board power supply. By default, control board is powered on automatically upon insertion to the cabinet or when house kee…
1.3.6.1.4.1.34.2.1.8TableioCabGenTablenot-accessiblemandatoryA table of general IO cabinet entries.
1.3.6.1.4.1.34.2.1.8.1RowioCabGenEntrynot-accessiblemandatoryA general I/O cabinet table entry.
1.3.6.1.4.1.34.2.1.8.1.1ColumnioCabGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.8.1.2ColumnioCabGenNumread-onlymandatoryA unique number assigned to an I/O Cabinet.
1.3.6.1.4.1.34.2.1.8.1.3ColumnioCabGenPowerread-writemandatoryA value identifying the current power state of an IO cabinet and also for powering on and off the I/O cabinet.
1.3.6.1.4.1.34.2.1.10TablefanTrayGenTablenot-accessiblemandatoryA table of fan tray entries.
1.3.6.1.4.1.34.2.1.10.1RowfanTrayGenEntrynot-accessiblemandatoryA fan tray table entry.
1.3.6.1.4.1.34.2.1.10.1.1ColumnfanTrayGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.10.1.2ColumnfanTrayGenNumread-onlymandatoryA unique number assigned to a fan tray.
1.3.6.1.4.1.34.2.1.10.1.3ColumnfanTrayGenPowerread-writemandatoryOn reading this object, it returns the power status of this fan tray. On writing it turns on/off the fan tray power.
1.3.6.1.4.1.34.2.1.11TablefanGenTablenot-accessiblemandatoryA table of fan entries. Each fan tray has certain number of fans. The number is represented by ConfMaxFanPerTray.
1.3.6.1.4.1.34.2.1.11.1RowfanGenEntrynot-accessiblemandatoryA fan tray entry containing information about a fan tray. Each fan entry is uniquely identified by 2 fields: fan tray number and fan number.
1.3.6.1.4.1.34.2.1.11.1.1ColumnfanGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.11.1.2ColumnfanGenTraySlotNumread-onlymandatoryA unique number assigned to a fan tray slot.
1.3.6.1.4.1.34.2.1.11.1.3ColumnfanGenNumread-onlymandatoryA unique number assigned to a fan inside this tray.
1.3.6.1.4.1.34.2.1.11.1.4ColumnfanGenStatusread-writemandatoryOn reading it returns the power status of this fan. On writing it allows an application to turn on/off this fan.
1.3.6.1.4.1.34.2.1.11.1.5ColumnfanGenSpeedread-writemandatoryOn reading it returns the speed of this fan inside a fan tray. On writing, it allows one to change the speed of this fan. Nominal is the medium speed the fan w…
1.3.6.1.4.1.34.2.1.11.1.6ColumnfanGenPowerControlread-writemandatoryThe MIB object that is used to either power on or off this fan. The power status of this fan should be read from the fanGenStatus MIB object. On writing, the f…
1.3.6.1.4.1.34.2.1.13TablesuppBrdGenTablenot-accessiblemandatoryA table of support board entries.
1.3.6.1.4.1.34.2.1.13.1RowsuppBrdGenEntrynot-accessiblemandatoryA support board table entry.
1.3.6.1.4.1.34.2.1.13.1.1ColumnsuppBrdGenIndexread-onlymandatoryA unique number assigned to this support board.
1.3.6.1.4.1.34.2.1.13.1.2ColumnsuppBrdGenNumread-onlymandatoryA unique number assigned to this support board.
1.3.6.1.4.1.34.2.1.13.1.3ColumnsuppBrdGenPowerread-onlymandatoryPower status of the support board.
1.3.6.1.4.1.34.2.1.13.1.4ColumnsuppBrdGenPowerControlread-writemandatoryOn reading it returns the power status of this support board power suuply. On writing, it turns on/off this support board power supply.
1.3.6.1.4.1.34.2.1.14TablebulkPowerGenTablenot-accessiblemandatoryA table of bulk power supply entries.
1.3.6.1.4.1.34.2.1.14.1RowbulkPowerGenEntrynot-accessiblemandatoryA bulk power supply table entry.
1.3.6.1.4.1.34.2.1.14.1.1ColumnbulkPowerGenIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.1.14.1.2ColumnbulkPowerGenNumread-onlymandatoryA unique number assigned to this bulk power supply.
1.3.6.1.4.1.34.2.1.14.1.3ColumnbulkPowerGenControlread-writemandatoryThe MIB object that is used to power off this bulk power supply. On writing, it powers off this bulk power supply.
1.3.6.1.4.1.34.2.1.14.1.4ColumnbulkPowerGenStatusread-onlymandatoryPower status of the bulk power supply. A status of ok implies the unit is on and supplying enough voltage/current. A status of fail implies the unit is on but …
1.3.6.1.4.1.34.2.2Nodeue10000
1.3.6.1.4.1.34.2.2.1TablesysBrdStarfireTablenot-accessiblemandatorySystem board table. The number host of entries in the table is represented by Conf.ConfNumSysBrd.
1.3.6.1.4.1.34.2.2.1.1RowsysBrdStarfireEntrynot-accessiblemandatoryA system board table entry.
1.3.6.1.4.1.34.2.2.1.1.1ColumnsysBrdStarfireIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.2.1.1.2ColumnsysBrdStarfireNumread-onlymandatoryA unique number assigned to a system board.
1.3.6.1.4.1.34.2.2.1.1.3ColumnsysBrdStarfireCIC0Tempread-onlymandatoryThe temperature of the CIC0 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.4ColumnsysBrdStarfireCIC1Tempread-onlymandatoryThe temperature of the CIC1 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.5ColumnsysBrdStarfireMCTempread-onlymandatoryThe temperature of the MC ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.6ColumnsysBrdStarfireXDB2Tempread-onlymandatoryThe temperature of the XDB2 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.7ColumnsysBrdStarfireXDB3Tempread-onlymandatoryThe temperature of the XDB3 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.8ColumnsysBrdStarfirePROC0Tempread-onlymandatoryThe temperature of the PROC0 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.9ColumnsysBrdStarfirePROC1Tempread-onlymandatoryThe temperature of the PROC1 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.10ColumnsysBrdStarfirePROC2Tempread-onlymandatoryThe temperature of the PROC2 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.11ColumnsysBrdStarfirePROC3Tempread-onlymandatoryThe temperature of the PROC3 ASIC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.12ColumnsysBrdStarfire3p3VDCTempread-onlymandatoryThe temperature of the PS2 3.3V DC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.13ColumnsysBrdStarfireVDCCoreTempread-onlymandatoryThe temperature of the PS3 VDD Core on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.14ColumnsysBrdStarfire5VDCTempread-onlymandatoryThe temperature of the PS5 5V DC on this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.15ColumnsysBrdStarfire3p3VDCread-onlymandatoryThe VDD voltage reading of this Starfire system board, which is equivalent to 3.3VDC.
1.3.6.1.4.1.34.2.2.1.1.16ColumnsysBrdStarfire5VDCHKread-onlymandatoryThe 5V DC housekeeping voltage reading of this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.17ColumnsysBrdStarfire5VDCread-onlymandatoryThe 5V DC voltage reading of this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.18ColumnsysBrdStarfireVDCCoreread-onlymandatoryThe VDD Core voltage reading of this Starfire system board.
1.3.6.1.4.1.34.2.2.1.1.19ColumnsysBrdStarfire3p3VDCHKread-onlymandatoryThe 3.3V DC voltage reading of this Starfire system board.
1.3.6.1.4.1.34.2.2.2TablecbStarfireTablenot-accessiblemandatoryA table of control board entries.
1.3.6.1.4.1.34.2.2.2.1RowcbStarfireEntrynot-accessiblemandatoryA control board table entry.
1.3.6.1.4.1.34.2.2.2.1.1ColumncbStarfireIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.2.2.1.2ColumncbStarfireNumread-onlymandatoryA unique number assigned to a control board.
1.3.6.1.4.1.34.2.2.2.1.3ColumncbStarfireHostNameread-onlymandatoryHost name assigned to this control board.
1.3.6.1.4.1.34.2.2.2.1.4ColumncbStarfire5VDCTempread-onlymandatoryThe temperature of PS1.
1.3.6.1.4.1.34.2.2.2.1.5ColumncbStarfire5VDCPerTempread-onlymandatoryThe temperature of PS2.
1.3.6.1.4.1.34.2.2.2.1.6ColumncbStarfire5VDCFanTempread-onlymandatoryThe temperature of PS3.
1.3.6.1.4.1.34.2.2.2.1.7ColumncbStarfireSen0Tempread-onlymandatoryThe temperature of the 1st temperature sensor.
1.3.6.1.4.1.34.2.2.2.1.8ColumncbStarfireSen1Tempread-onlymandatoryThe temperature of the 2nd temperature sensor.
1.3.6.1.4.1.34.2.2.2.1.9ColumncbStarfireSen2Tempread-onlymandatoryThe temperature of the 3rd temperature sensor.
1.3.6.1.4.1.34.2.2.2.1.10ColumncbStarfire5VDCread-onlymandatoryThe voltage reading of 5V DC.
1.3.6.1.4.1.34.2.2.2.1.11ColumncbStarfire5VDCHKread-onlymandatoryThe voltage reading of housekeeping 5V DC.
1.3.6.1.4.1.34.2.2.2.1.12ColumncbStarfire3p3VDCHKread-onlymandatoryThe voltage reading of housekeeping 3.3V DC.
1.3.6.1.4.1.34.2.2.2.1.13ColumncbStarfire5VDCPerread-onlymandatoryThe voltage reading of VccPer.
1.3.6.1.4.1.34.2.2.2.1.14ColumncbStarfire5VDCFanread-onlymandatoryThe voltage reading of VccFan.
1.3.6.1.4.1.34.2.2.3TablecenterplaneStarfireTablenot-accessiblemandatoryA table of centerplane entries.
1.3.6.1.4.1.34.2.2.3.1RowcenterplaneStarfireEntrynot-accessiblemandatoryA centerplane table entry.
1.3.6.1.4.1.34.2.2.3.1.1ColumncenterplaneStarfireIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.2.3.1.2ColumncenterplaneStarfireNumread-onlymandatoryA unique number assigned to this centerplane.
1.3.6.1.4.1.34.2.2.3.1.3ColumncenterplaneStarfireTemp0read-onlymandatoryThe 1st temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.4ColumncenterplaneStarfireTemp1read-onlymandatoryThe 2nd temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.5ColumncenterplaneStarfireTemp2read-onlymandatoryThe 3rd temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.6ColumncenterplaneStarfireTemp3read-onlymandatoryThe 4th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.7ColumncenterplaneStarfireTemp4read-onlymandatoryThe 5th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.8ColumncenterplaneStarfireTemp5read-onlymandatoryThe 6th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.9ColumncenterplaneStarfireTemp6read-onlymandatoryThe 7th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.10ColumncenterplaneStarfireTemp7read-onlymandatoryThe 8th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.11ColumncenterplaneStarfireTemp8read-onlymandatoryThe 9th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.3.1.12ColumncenterplaneStarfireTemp9read-onlymandatoryThe 10th temp point of this Starfire centerplane.
1.3.6.1.4.1.34.2.2.4TablesuppBrdStarfireTablenot-accessiblemandatoryA table of support board entries.
1.3.6.1.4.1.34.2.2.4.1RowsuppBrdStarfireEntrynot-accessiblemandatoryA support board table entry.
1.3.6.1.4.1.34.2.2.4.1.1ColumnsuppBrdStarfireIndexread-onlymandatoryAn index into this table.
1.3.6.1.4.1.34.2.2.4.1.2ColumnsuppBrdStarfireNumread-onlymandatoryA unique number assigned to this support board.
1.3.6.1.4.1.34.2.2.4.1.3ColumnsuppBrdStarfire3p3VDC1Tempread-onlymandatoryThe PS1 temp point of this Starfire support board.
1.3.6.1.4.1.34.2.2.4.1.4ColumnsuppBrdStarfire3p3VDC2Tempread-onlymandatoryThe PS2 temp point of this Starfire support board.
1.3.6.1.4.1.34.2.2.4.1.5ColumnsuppBrdStarfire5VDCHKread-onlymandatoryThe 5V DC voltage in this Starfire support board.
1.3.6.1.4.1.34.2.2.4.1.6ColumnsuppBrdStarfire3p3VDCHKread-onlymandatoryThe 3.3V DC housekeeping voltage in this Starfire support board.
1.3.6.1.4.1.34.2.2.4.1.7ColumnsuppBrdStarfire3p3VDCread-onlymandatoryThe CP 3.3V DC housekeeping voltage in this Starfire support board.
1.3.6.1.4.1.34.2.3Nodessp
1.3.6.1.4.1.34.2.3.1NodesspPlatformApp
1.3.6.1.4.1.34.2.3.1.1ScalarsspPlatformAppEddControlread-writemandatoryThe object identifies the action intended for the EDD. Changing this object will cause the agent to send a eddControl trap. Reading this object returns the las…
1.3.6.1.4.1.34.2.3.1.2ScalarsspPlatformAppEddStateread-writemandatoryThe object identifies the current state of the Event Detector Daemon. Changing this object will cause the agent to send a eddState trap. Reading this object re…
1.3.6.1.4.1.34.3NodesysBrdTempNormThis trap indicates a System Board transition from over temperature reading to normal. The platform name and board number will always be provided with this tra…
1.3.6.1.4.1.34.4NodesysBrdTempHighThis trap indicates a System Board high temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only…
1.3.6.1.4.1.34.5NodesysBrdTempWarnThis trap indicates a System Board warning temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, o…
1.3.6.1.4.1.34.6NodesysBrdTempMaxThis trap indicates a System Board max temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only …
1.3.6.1.4.1.34.7NodesysBrdTemp911This trap indicates a System Board 911 temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only …
1.3.6.1.4.1.34.8NodesysBrdTempBadThis trap indicates a System Board bad temperature reading. This means that at least half the temperature sensors on the board report invalid temperature readi…
1.3.6.1.4.1.34.9NodesysBrdTempChangeThis trap indicates that a System Board temperature reading has changed within a specified delta. The platform name and board number variables will always be p…
1.3.6.1.4.1.34.10NodecbTempNormThis trap indicates a Control Board transition to normal temperature reading. The platform name and board number variables will always be provided with this tr…
1.3.6.1.4.1.34.11NodecbTempHighThis trap indicates a Control Board high temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, onl…
1.3.6.1.4.1.34.12NodecbTempWarnThis trap indicates a Control Board warning temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, …
1.3.6.1.4.1.34.13NodecbTempMaxThis trap indicates a Control Board max temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only…
1.3.6.1.4.1.34.14NodecbTemp911This trap indicates a Control Board 911 temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only…
1.3.6.1.4.1.34.15NodecbTempBadThis trap indicates a Control Board bad temperature reading. This means that at least half the temperature sensors on the board report invalid temperature read…
1.3.6.1.4.1.34.16NodecbTempChangeThis trap indicates that a Control Board temperature reading has changed within a specified delta. The platform name and board number variables will always be …
1.3.6.1.4.1.34.17NodecenterplaneTempNormThis trap indicates a Centerplane transition to normal temperature reading. The platform name and board number variables will always be provided with this trap…
1.3.6.1.4.1.34.18NodecenterplaneTempHighThis trap indicates a Centerplane high temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only …
1.3.6.1.4.1.34.19NodecenterplaneTempWarnThis trap indicates a Centerplane warning temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, on…
1.3.6.1.4.1.34.20NodecenterplaneTempMaxThis trap indicates a Centerplane max temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only t…
1.3.6.1.4.1.34.21NodecenterplaneTemp911This trap indicates a Centerplane 911 temperature reading. The platform name and board number variables will always be provided with this trap. Whereas, only t…
1.3.6.1.4.1.34.22NodecenterplaneTempBadThis trap indicates a Centerplane bad temperature reading. This means that at least half the temperature sensors on the board report invalid temperature readin…
1.3.6.1.4.1.34.23NodecenterplaneTempChangeThis trap indicates that a Centerplane temperature reading has changed within a specified delta. The platform name and board number variables will always be pr…
1.3.6.1.4.1.34.24NodecbeConnectedThis trap indicates that the control board server (cbs) is connected to the control board executive (cbe) and is ready for control board operation. All variabl…
1.3.6.1.4.1.34.25NodecbeDisconnectedThis trap indicates that the control board server (cbs) has lost connection with the control board executive (cbe). All variables are mandatory for this trap.
1.3.6.1.4.1.34.26NodesuppBrdTempNormThis trap indicates a Centerplane Support Board transition from over temperature reading to normal. The platform name and board number variables will always be…
1.3.6.1.4.1.34.27NodesuppBrdTempHighThis trap indicates a Centerplane Support Board high temperature reading. The platform name and board number variables will always be provided with this trap. …
1.3.6.1.4.1.34.28NodesuppBrdTempWarnThis trap indicates a Centerplane Support Board warning temperature reading. The platform name and board number variables will always be provided with this tra…
1.3.6.1.4.1.34.29NodesuppBrdTempMaxThis trap indicates a Centerplane Support Board max temperature reading. The platform name and board number variables will always be provided with this trap. W…
1.3.6.1.4.1.34.30NodesuppBrdTemp911This trap indicates a Centerplane Support Board 911 temperature reading. The platform name and board number variables will always be provided with this trap. W…
1.3.6.1.4.1.34.31NodesuppBrdTempBadThis trap indicates a Centerplane Support Board bad temperature reading. This means that half the temperature sensors on the board do not report valid temperat…
1.3.6.1.4.1.34.32NodesuppBrdTempChangeThis trap indicates that a Centerplane Support Board temperature reading has changed within a specified delta. The platform name and board number variables wil…
1.3.6.1.4.1.34.33NodesysBrdVoltNormThis trap indicates a System Board transition from low or high power reading to normal. The platform name and board number variables will always be provided wi…
1.3.6.1.4.1.34.34NodesysBrdVoltMaxThis trap indicates a System Board max voltage reading. The platform name and board number variables will always be provided with this trap. Whereas, only thos…
1.3.6.1.4.1.34.35NodesysBrdVoltMinThis trap indicates a System Board min voltage reading. The platform name and board number variables will always be provided with this trap. Whereas, only thos…
1.3.6.1.4.1.34.36NodesysBrdVoltBadThis trap indicates a System Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The pla…
1.3.6.1.4.1.34.37NodesysBrdVoltChangeThis trap indicates a System Board voltage reading has changed within a specified delta. The platform name and board number variables will always be provided w…
1.3.6.1.4.1.34.38NodecbVoltNormThis trap indicates a Control Board transition to normal voltage reading. The platform name and board number variables will always be provided with this trap. …
1.3.6.1.4.1.34.39NodecbVoltMaxThis trap indicates a Control Board max voltage reading. The platform name and board number variables will always be provided with this trap. Whereas, only tho…
1.3.6.1.4.1.34.40NodecbVoltMinThis trap indicates a Control Board min voltage reading. The platform name and board number variables will always be provided with this trap. Whereas, only tho…
1.3.6.1.4.1.34.41NodecbVoltBadThis trap indicates a Control Board bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The pl…
1.3.6.1.4.1.34.42NodecbVoltChangeThis trap indicates a Control Board voltage reading has changed within a specified delta. The platform name and board number variables will always be provided …
1.3.6.1.4.1.34.43NodecenterplaneVoltNormThis trap indicates a Centerplane transition to normal voltage reading. The platform name and board number variables will always be provided with this trap.' W…
1.3.6.1.4.1.34.44NodecenterplaneVoltMaxThis trap indicates a Centerplane max voltage reading. The platform name and board number variables will always be provided with this trap. Whereas, only those…
1.3.6.1.4.1.34.45NodecenterplaneVoltMinThis trap indicates a Centerplane Min voltage reading. The platform name and board number variables will always be provided with this trap. Whereas, only those…
1.3.6.1.4.1.34.46NodecenterplaneVoltBadThis trap indicates a Centerplane bad voltage reading. This means that at least half the voltage sensors on the board report invalid voltage readings. The plat…
1.3.6.1.4.1.34.47NodecenterplaneVoltChangeThis trap indicates a Centerplane voltage reading has changed within a specified delta. The platform name and board number variables will always be provided wi…
1.3.6.1.4.1.34.48NodesuppBrdVoltNormThis trap indicates a Centerplane Support Board transition from over voltage reading to normal. The platform name and board number variables will always be pro…
1.3.6.1.4.1.34.49NodesuppBrdVoltMaxThis trap indicates a Centerplane Support Board max voltage reading. The platform name and board number variables will always be provided with this trap. Where…
1.3.6.1.4.1.34.50NodesuppBrdVoltMinThis trap indicates a Centerplane Support Board Min voltage reading. The platform name and board number variables will always be provided with this trap. Where…
1.3.6.1.4.1.34.51NodesuppBrdVoltBadThis trap indicates a Centerplane Support Board bad voltage reading. This means that half the voltage sensors on the board do not report valid voltage readings…
1.3.6.1.4.1.34.52NodesuppBrdVoltChangeThis trap indicates a Centerplane Support Board voltage reading has changed within a specified delta. The platform name and board number variables will always …
1.3.6.1.4.1.34.53NodefanNormThis trap indicates a fan transition from failed to normal. All variables are mandatory for this trap.
1.3.6.1.4.1.34.54NodefanFailThis trap indicates a fan failure. All variables are mandatory for this trap.
1.3.6.1.4.1.34.55NodesystemConfigurationChangeThis trap indicates that the system configuration has changed. It indicates what boards have been inserted or removed. The platform name will always be provide…
1.3.6.1.4.1.34.56NodearbitrationStopThis trap indicates that a particular domain has experienced an arbstop. All variables will be provided with this trap.
1.3.6.1.4.1.34.57NoderecordStopThis trap indicates that a particular domain has experienced a recordarbstop. All variables will be provided with this trap.
1.3.6.1.4.1.34.58NodewatchdogThis trap indicates that a particular domain has experienced a watchdog. All variables will be provided with this trap.
1.3.6.1.4.1.34.59NodeenvironmentalShutdownThis trap indicates that a particular domain has experienced an environmental shutdown. All variables will be provided with this trap.
1.3.6.1.4.1.34.60NoderebootThis trap indicates that a particular domain has experienced a reboot. All variables will be provided with this trap.
1.3.6.1.4.1.34.61Nodepanic1This trap indicates that a particular domain has experienced a panic1. All variables will be provided with this trap.
1.3.6.1.4.1.34.62Nodepanic2This trap indicates that a particular domain has experienced a panic2. All variables will be provided with this trap.
1.3.6.1.4.1.34.63NodepanicRebootThis trap indicates that a particular domain has experienced a panic_reboot. All variables will be provided with this trap.
1.3.6.1.4.1.34.64NodeheartbeatFailureThis trap indicates that a particular domain has experienced a heartbeat_failure. All variables will be provided with this trap.
1.3.6.1.4.1.34.65NodesignatureBlockChangeThis trap indicates that the signature block has changed. All variables will be provided with this trap.
1.3.6.1.4.1.34.66NodesysbrdPowerOffThis trap indicates that a system board has been powered off. The platform name will always be provided whereas one or more board number identifiers will be pr…
1.3.6.1.4.1.34.67NodesysbrdPowerOnThis trap indicates that a system board has been powered on. The platform name will always be provided whereas one or more board number identifiers will be pro…
1.3.6.1.4.1.34.68NodesuppbrdPowerOffThis trap indicates that a support board has been powered off. The platform name will always be provided whereas one or more board number identifiers will be p…
1.3.6.1.4.1.34.69NodesuppbrdPowerOnThis trap indicates that a support board has been powered on. The platform name will always be provided whereas one or more board number identifiers will be pr…
1.3.6.1.4.1.34.70NodebulkPowerNormThis trap indicates that a particular Bulk Power has returned to (or is in) normal mode. All variables are mandatory for this trap.
1.3.6.1.4.1.34.71NodebulkPowerFailThis trap indicates Bulk Power failure. All variables are mandatory for this event.
1.3.6.1.4.1.34.72NodebootProcChangeThis trap indicates a change in the Boot Proc. All variables are mandatory for this event.
1.3.6.1.4.1.34.73NodesigObpBootingThis trap indicates that a proc in a particular domain has experienced a signature change indicating the domain is booting. The signature block specifies signa…
Type Definitions
NameSyntaxStatusDescription
BooleanINTEGER { true(1), false(2) }
DisplayStringOCTET STRING
YesNoINTEGER { yes(1), no(2) }