MIB Viewer

CXAsync-MIB

139 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.495.2.1.6.30.1NodeasySapAlarmIndicates that the global object asyStatusEvent has occurred at the identified SAP (service access point) if the global object asyAlarms is enabled.
1.3.6.1.4.1.495.2.1.6.30.1ScalarasyX25TxQThresholdread-writemandatoryDefines the global X.25 queue threshold, in number of frames. When the threshold is exceeded and the SAP (service access point) object asySapNetworkFlowControl…
1.3.6.1.4.1.495.2.1.6.30.2ScalarasyPadIdBannerread-writemandatoryDefines the Async PAD Identification Banner. This banner is transmitted to the attached device whenever it raises interface signals. Range of Values: 1 - 255 D…
1.3.6.1.4.1.495.2.1.6.30.7ScalarasyAlarmsread-writemandatoryIndicates whether this layer produces the object asySapAlarm trap. Options: disabled (1) enable (2) Default Value: disable Configuration Changed: Administrative
1.3.6.1.4.1.495.2.1.6.30.8ScalarasySapStatusEventread-onlymandatoryIdentifies the status generated in the object asyAlarmTrap. This object is used for identification by the trap when it occurs and will always return the value …
1.3.6.1.4.1.495.2.1.6.30.9ScalarasySoftwareVersionsread-onlymandatoryIdentifies the revision numbers of the Async layer software. This is a read-only parameter that displays the revision number as a string of five numbers. Each …
1.3.6.1.4.1.495.2.1.6.30.10ScalarasyMibLevelread-onlymandatoryUsed to determine current MIB module release supported by the agent. Object is in decimal.
1.3.6.1.4.1.495.2.1.6.30.20TableasySapTablenot-accessiblemandatoryContains configuration information about each Async layer SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1RowasySapEntrynot-accessiblemandatoryContains the parameters for a specific Async layer SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.1ColumnasySapNumberread-onlymandatoryIndicates the table row containing configuration or monitoring objects for a SAP (service access point) associated with the slot of a card, a port of this card…
1.3.6.1.4.1.495.2.1.6.30.20.1.2ColumnasySapRowStatusread-writemandatoryIndicates whether or not this specific entry is configured within the MIB. Options: invalid (1): Row is flagged and deleted from the table after the next reset…
1.3.6.1.4.1.495.2.1.6.30.20.1.3ColumnasySapAliasread-writemandatoryDetermines the name which uniquely identifies the SAP (service access point). Range of Values: 1 to 16 alphanumeric characters beginning with an alpha characte…
1.3.6.1.4.1.495.2.1.6.30.20.1.4ColumnasySapMCompanionAliasread-writemandatoryDetermines the name which uniquely identifies the companion MAC SAP (service access point) which will communicate with this SAP. Range of Values: 1 to 16 alpha…
1.3.6.1.4.1.495.2.1.6.30.20.1.5ColumnasySapNCompanionAliasread-writemandatoryDetermines the name which uniquely identifies the X.25 SAP (service access point) which will communicate with this SAP. Range of Values: 1 to 16 alphanumeric c…
1.3.6.1.4.1.495.2.1.6.30.20.1.6ColumnasySapX3Profileread-writemandatoryTells the SAP (service access point) which set of X.3 parameters to use. Range of Values: 1 - 255 Default Value: 92 Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.7ColumnasySapNUIread-writemandatoryDefines the Network User ID for this SAP (service access point). Options: 1 to 14 alphanumeric characters Default Value: 0 Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.8ColumnasySapAddressread-writemandatoryDefines the calling address for this SAP (service access point). Range of Values: 1 to 15 digits Default Value: 0 Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.9ColumnasySapDisconnectRequestread-writemandatorySends a Disconnect Request to the MAC layer when the YT timer expires. Options: Yes = Enable the disconnect request No = Disable the disconnect request Default…
1.3.6.1.4.1.495.2.1.6.30.20.1.10ColumnasySapRxThruputClassread-writemandatoryDefines the default receive throughput class that is used at this SAP (service access point). Range of Values: 75 - 64000 bps Default Value: 9600 bps Configura…
1.3.6.1.4.1.495.2.1.6.30.20.1.11ColumnasySapTxThruputClassread-writemandatoryDefines the default transmit throughput class that is used at this SAP (service access point). Range of Values: 75 to 64000 bps Default Value: 9600 bps Configu…
1.3.6.1.4.1.495.2.1.6.30.20.1.12ColumnasySapTxPacketSizeread-writemandatoryDefines the size of the transmit packet for the Async layer. Range of Values: 16 to 4096 bytes Default Value: 128 bytes Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.13ColumnasySapRxPacketSizeread-writemandatoryDefines the size of the receive packet for the Async layer. Range of Values: 16 to 4096 bytes Default Value: 128 bytes Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.14ColumnasySapTxWindowSizeread-writemandatoryDefines the size of the transmit window for the Async layer. Range of Values: 1 to 127 Default Value: 2 Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.15ColumnasySapRxWindowSizeread-writemandatoryDefines the size of the receive window for the Async layer. Range of Values: 1 to 127 Default Value: 2 Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.16ColumnasySapYTTimerread-writemandatoryDefines the time of inactivity, in seconds, after which the SAP (service access point) will send a disconnect request to the MAC layer. The timer starts when t…
1.3.6.1.4.1.495.2.1.6.30.20.1.17ColumnasySapSRTimerread-writemandatoryDefines the time of inactivity, in seconds, between command characters. The timer starts when the command mode is entered or when a character of a command is e…
1.3.6.1.4.1.495.2.1.6.30.20.1.18ColumnasySapNUILengthread-writeobsoleteDefines the length, in nibbles, allowed for the Network User ID. Range of Values: 1 to 14 Default Value: 0 Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.19ColumnasySapReverseChargingAcceptanceread-writemandatoryAuthorizes the DCE (Async application) to transmit incoming calls to the DTE (Async user) that requested the reverse charging, if reverse charging acceptance i…
1.3.6.1.4.1.495.2.1.6.30.20.1.20ColumnasySapChargingInformationread-writemandatoryAuthorizes the DCE (Async application) to send charging information to the DTE (user) with the Clear Indication or Clear Confirmation packet. Options: Yes No D…
1.3.6.1.4.1.495.2.1.6.30.20.1.21ColumnasySapSubscriptionCUGread-writemandatoryEnables the DTE (User) to subscribe to one or more CUGs (Closed User Groups). A CUG permits the DTEs belonging to the group to communicate with each other in t…
1.3.6.1.4.1.495.2.1.6.30.20.1.22ColumnasySapSubscriptionCUGOAread-writemandatoryEnables the DTE (user) to subscribe to one or more CUGs (Closed User Groups), as in object asySapSubscriptionCUG, with outgoing access. The DTE can originate v…
1.3.6.1.4.1.495.2.1.6.30.20.1.23ColumnasySapSubscriptionCUGIAread-writemandatoryEnables the DTE (user) to subscribe to one or more CUGs (Closed User Groups), as in object asySapSubscriptionCUG, with incoming access. The DTE can receive inc…
1.3.6.1.4.1.495.2.1.6.30.20.1.24ColumnasySapPreferentialCUGIndexread-writemandatoryDefines the preferential CUG (Closed User Group) for a DTE (user) with a CUG, CUGOA or CUGIA subscription. Range of Values: 0 to 99 Note: 0 = No preferential C…
1.3.6.1.4.1.495.2.1.6.30.20.1.25ColumnasySapReceiptConfirmationread-writemandatoryTells the X.25 layer which receipt confirmation value is required by this SAP (service access point). Options: noAck dBit localAck xmitAck Default Value: noAck…
1.3.6.1.4.1.495.2.1.6.30.20.1.26ColumnasySapEnableProtocolIdread-writemandatoryControls whether or not the Protocol ID field of the user data is inserted by the Async layer. Options: enable = Allows up to 12 bytes, or 124 bytes for fast s…
1.3.6.1.4.1.495.2.1.6.30.20.1.27ColumnasySapProtocolIdread-writemandatoryDefines the protocol format that is used for incoming call or call request packets to the X.25 call data field. The field consists of 4 hexadecimal octets wher…
1.3.6.1.4.1.495.2.1.6.30.20.1.28ColumnasySapPromptSignalread-writemandatoryDefines the prompt PAD service signal (banner) that is sent to the MAC layer whenever the Async PAD enters a PAD waiting state or waiting for command state. Op…
1.3.6.1.4.1.495.2.1.6.30.20.1.29ColumnasySapAutoConnectDteIdread-writemandatoryIdentifies the remote DTE (by name) to be connected to whenever the async sap receives a Connect Indication or Connect Confirm from the MAC layer. If no name i…
1.3.6.1.4.1.495.2.1.6.30.20.1.30ColumnasySapAutoConnectRetryread-writemandatoryDefines the number of times this async sap will try to connect (if Connect Accept is not received from the X.25 layer) to the remote DTE defined by the object …
1.3.6.1.4.1.495.2.1.6.30.20.1.31ColumnasySapAutoConnectDelayTimerread-writemandatoryDefines the time in seconds this async sap will wait before trying to connect to the remote DTE defined by the object asySapAutoConnectDteId whenever the async…
1.3.6.1.4.1.495.2.1.6.30.20.1.32ColumnasySapHardwareFlowControlread-writemandatoryEnables the MAC to flow control the device via the EIA RTS/CTS signal. Options: Yes No Default Value: No Configuration Changed: Operative
1.3.6.1.4.1.495.2.1.6.30.20.1.33ColumnasySapProtocolTyperead-writemandatoryDefines the Async Protocol type for this sap. Options: normal (1) for Normal Async (X.3, X.28, X.29) protocol. iocProtocol (2) for IOC Protocol. ModifiedUDF (3…
1.3.6.1.4.1.495.2.1.6.30.20.1.37ColumnasySapControlwrite-onlymandatoryDefines the control that is used with the specified Async layer SAP (service access point). Options: clearStats (1): Zeros all the statistic counters for this …
1.3.6.1.4.1.495.2.1.6.30.20.1.40ColumnasySapStateread-onlymandatoryIndicates the current state of the Async layer SAP(service access point). Options: disconnected (1) enabled (2) connecting (3) data Transfer (4) resetting (5) …
1.3.6.1.4.1.495.2.1.6.30.20.1.41ColumnasySapAsyncFlowControlStateread-onlymandatoryIndicates whether this SAP (service access point) was forced to initiate flow control procedures by the MAC (media access control) layer. Options: flowControlO…
1.3.6.1.4.1.495.2.1.6.30.20.1.42ColumnasySapNetworkFlowControlStateread-onlymandatoryIndicates whether or not this SAP (service access point) was forced to initiate flow control procedures by the network layer. Options: flowControlOff (1) flowC…
1.3.6.1.4.1.495.2.1.6.30.20.1.43ColumnasySapAsyncTxQueueSizeread-onlymandatoryIndicates the current number of frames to be transmitted to the MAC (media access control) layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.44ColumnasySapX25TxQueueSizeread-onlymandatoryIndicates the current number of frames to be send to the network layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.50ColumnasySapNumberConnectsread-onlymandatoryIndicates the number of call attempts by this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.51ColumnasySapNumberDisconnectsread-onlymandatoryIndicates the number of disconnects for this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.52ColumnasySapTxDataCharactersread-onlymandatoryIndicates the number of data characters that were transmitted from this SAP (service access point) to the MAC layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.53ColumnasySapRxDataCharactersread-onlymandatoryIndicates the number of data characters that were received at this SAP (service access point) from the MAC layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.54ColumnasySapParityErrorsread-onlymandatoryIndicates the number of characters with parity errors that were received at this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.55ColumnasySapOverrunsread-onlymandatoryIndicates the number of characters with overrun errors that were received at this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.56ColumnasySapFlowControlByUserread-onlymandatoryIndicates the number of flow control characters that were received by this SAP (service access point) from the Async port.
1.3.6.1.4.1.495.2.1.6.30.20.1.57ColumnasySapFlowControlByX25read-onlymandatoryIndicates the number of flow control messages that were received by this SAP (service access point) from the network layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.58ColumnasySapFlowControlToUserread-onlymandatoryIndicates the number of flow control characters that were transmitted by this SAP (service access point) to the Async port.
1.3.6.1.4.1.495.2.1.6.30.20.1.59ColumnasySapFlowControlToX25read-onlymandatoryIndicates the number of flow control messages that were sent by this SAP (service access point) to the network layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.60ColumnasySapRxResetread-onlymandatoryIndicates the number of resets that were received at this SAP (service access point) from the network layer.
1.3.6.1.4.1.495.2.1.6.30.20.1.61ColumnasySapRxBreakread-onlymandatoryIndicates the number of breaks that were received at this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.62ColumnasySapTxBreakread-onlymandatoryIndicates the number of breaks that were transmitted from this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.20.1.63ColumnasySapRxDiscardCharactersread-onlymandatoryIndicates the number of discard characters that were received at this SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.21TableasyProfTablenot-accessiblemandatoryContains the X.3 parameters for each defined X.3 profile.
1.3.6.1.4.1.495.2.1.6.30.21.1RowasyProfEntrynot-accessiblemandatoryProvides the parameters for a specific X.3 profile SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.21.1.1ColumnasyProfNumberread-onlymandatoryIdentifies the profile SAP (service access point) using a unique numerical value.
1.3.6.1.4.1.495.2.1.6.30.21.1.2ColumnasyProfRowStatusread-writemandatoryIndicates whether or not this specific entry is configured within the MIB. Options: invalid (1): Row is flagged and deleted from the table after the next reset…
1.3.6.1.4.1.495.2.1.6.30.21.1.3ColumnasyProfAliasread-writemandatoryIdentifies the SAP (service access point) using a unique textual name. Range of Values: 1 to 16 alphanumeric characters beginning with an alpha character Defau…
1.3.6.1.4.1.495.2.1.6.30.21.1.5ColumnasyProfParameter1read-writemandatoryDefines the X.3 parameter 1, PAD recall using a character. This parameter allows the start-stop mode DTE (user) to initiate an escape from the data transfer or…
1.3.6.1.4.1.495.2.1.6.30.21.1.6ColumnasyProfParameter2read-writemandatoryDefines the X.3 parameter 2, Echo. This parameter provides for characters received from the start-stop mode DTE (user) to be transmitted back to the start-stop…
1.3.6.1.4.1.495.2.1.6.30.21.1.7ColumnasyProfParameter3read-writemandatoryDefines the X.3 parameter 3, Selection of data forwarding character(s). This parameter allows the selection of defined sets of characters received from the sta…
1.3.6.1.4.1.495.2.1.6.30.21.1.8ColumnasyProfParameter4read-writemandatoryDefines the X.3 parameter 4, Selection of idle timer delay, in tenths of a second. This parameter allows the selection of the duration of an interval between s…
1.3.6.1.4.1.495.2.1.6.30.21.1.9ColumnasyProfParameter5read-writemandatoryDefines the X.3 parameter 5, Ancillary device control. This parameter allows for flow control between the PAD and the start-stop mode DTE (user). Options: 0: N…
1.3.6.1.4.1.495.2.1.6.30.21.1.10ColumnasyProfParameter6read-writemandatoryDefines the X.3 parameter 6, Control of PAD service signals and PAD command signals. This parameter provides the start-stop mode DTE (user) with the ability to…
1.3.6.1.4.1.495.2.1.6.30.21.1.11ColumnasyProfParameter7read-writemandatoryDefines the X.3 parameter 7, Selection of operation of the PAD on receipt of a break signal from the start-stop mode DTE. This parameter allows the selection o…
1.3.6.1.4.1.495.2.1.6.30.21.1.12ColumnasyProfParameter8read-writemandatoryDefines the X.3 parameter 8, Discard output. This parameter provides for a PAD to discard the content of user sequences in packets upon request rather than dis…
1.3.6.1.4.1.495.2.1.6.30.21.1.13ColumnasyProfParameter9read-writemandatoryDefines the X.3 parameter 9, Padding after carriage return (CR). This parameter provides for the automatic insertion of padding characters by the PAD after a c…
1.3.6.1.4.1.495.2.1.6.30.21.1.14ColumnasyProfParameter10read-writemandatoryDefines the X.3 parameter 10, Line folding. This parameter provides for the automatic insertion of graphic characters by the PAD in the character stream transm…
1.3.6.1.4.1.495.2.1.6.30.21.1.15ColumnasyProfParameter11read-onlymandatoryDefines the X.3 parameter 11, Binary speed of start-stop mode DTE. Options: 0: 110 bit/s 1: 134.5 bit/s 2: 300 bit/s 3: 1200 bit/s 4: 600 bit/s 5: 75 bit/s 6: …
1.3.6.1.4.1.495.2.1.6.30.21.1.16ColumnasyProfParameter12read-writemandatoryDefines the X.3 parameter 12, Flow control of the PAD. This parameter allows for flow control between the start-stop mode DTE (user) and the PAD. Options: 0: N…
1.3.6.1.4.1.495.2.1.6.30.21.1.17ColumnasyProfParameter13read-writemandatoryDefines the X.3 parameter 13, Linefeed insertion after carriage return. This parameter allows for the automatic insertion of a linefeed character in the charac…
1.3.6.1.4.1.495.2.1.6.30.21.1.18ColumnasyProfParameter14read-writemandatoryDefines the X.3 parameter 14, Padding after linefeed. This parameter provides for the automatic insertion of padding characters in the character stream transmi…
1.3.6.1.4.1.495.2.1.6.30.21.1.19ColumnasyProfParameter15read-writemandatoryDefines the X.3 parameter 15, Editing. This parameter provides for character size delete, line delete and line display editing capabilities in the PAD command …
1.3.6.1.4.1.495.2.1.6.30.21.1.20ColumnasyProfParameter16read-writemandatoryDefines the X.3 parameter 16, Character delete. Range of Values: 0 to 127 0 to126: One character from IA5 127: Character 7/15 (DEL) Default Value: 0 Configurat…
1.3.6.1.4.1.495.2.1.6.30.21.1.21ColumnasyProfParameter17read-writemandatoryDefines the X.3 parameter 17, Line delete. Range of Values: 0 to 127 0 to 23: One character from the range of IA5 24: Character 1/8 (CAN) 25 to 127: One charac…
1.3.6.1.4.1.495.2.1.6.30.21.1.22ColumnasyProfParameter18read-writemandatoryDefines the X.3 parameter 18, Line display. Range of Values: 0 to 127 0 to 17: One character from the range of IA5 18: Character 1/8 (DC2) 19 to 127: One chara…
1.3.6.1.4.1.495.2.1.6.30.21.1.23ColumnasyProfParameter19read-writemandatoryDefines the X.3 parameter 19, Editing PAD service signals. This parameter provides the start-stop mode DTE (user) with the ability to decide whether or not edi…
1.3.6.1.4.1.495.2.1.6.30.21.1.24ColumnasyProfParameter20read-writemandatoryDefines the X.3 parameter 20, Echo mask. This parameter allows selected defined sets of characters received from the start-stop mode DTE (user) not to be trans…
1.3.6.1.4.1.495.2.1.6.30.21.1.25ColumnasyProfParameter21read-writemandatoryDefines the X.3 parameter 21, Parity treatment. This parameter allows the PAD to check parity in the data stream from the start-stop mode DTE (user) or generat…
1.3.6.1.4.1.495.2.1.6.30.21.1.26ColumnasyProfParameter22read-writemandatoryDefines the X.3 parameter 22, Page wait. This parameter allows the PAD to suspend transmission of additional characters to the start-stop mode DTE (user) after…
1.3.6.1.4.1.495.2.1.6.30.21.1.27ColumnasyProfParameter23read-writemandatoryDefines parameter 23 (extension to X.3), Receive parity type. Options: 0: Parity disable 1: Even parity 2: Odd parity 3: Space parity 4: Mark parity Default Va…
1.3.6.1.4.1.495.2.1.6.30.21.1.28ColumnasyProfParameter24read-writemandatoryDefines parameter 24 (extension to X.3), Transmit parity type. Options: 0: Parity disable 1: Even parity 2: Odd parity 3: Space parity 4: Mark parity Default V…
1.3.6.1.4.1.495.2.1.6.30.21.1.29ColumnasyProfParameter25read-writemandatoryDefines parameter 25 (extension to X.3), Flow control on character to PAD. Range of Values: 0 to 127 Note: 0 to 18: One character from the range of IA5 19: DC3…
1.3.6.1.4.1.495.2.1.6.30.21.1.30ColumnasyProfParameter26read-writemandatoryDefines parameter 26 (extension to X.3), Flow control off character to PAD. Range of Values: 0 to 127 0 to 16: One character from the range of IA5 17: DC1 18 t…
1.3.6.1.4.1.495.2.1.6.30.21.1.31ColumnasyProfParameter27read-writemandatoryDefines parameter 27 (extension to X.3), Flow control on character to ancillary device. Range of Values: 0 to 127 Note: 0 to 18: One character from the range o…
1.3.6.1.4.1.495.2.1.6.30.21.1.32ColumnasyProfParameter28read-writemandatoryDefines parameter 28 (extension to X.3), Flow control off character to ancillary device. Range of Values: 0 to 127 0 to 16: One character from the range of IA5…
1.3.6.1.4.1.495.2.1.6.30.22TableasySapProfTablenot-accessiblemandatoryContains the operational X.3 parameters for each async SAP (service access point).
1.3.6.1.4.1.495.2.1.6.30.22.1RowasySapProfEntrynot-accessiblemandatoryProvides the operational X.3 parameters for a specific async sap.
1.3.6.1.4.1.495.2.1.6.30.22.1.1ColumnasySapProfSapNumberread-onlymandatoryIdentifies the SAP (service access point) using a unique numerical value.
1.3.6.1.4.1.495.2.1.6.30.22.1.5ColumnasySapProfParameter1read-writemandatoryDefines the X.3 parameter 1, PAD recall using a character. This parameter allows the start-stop mode DTE (user) to initiate an escape from the data transfer or…
1.3.6.1.4.1.495.2.1.6.30.22.1.6ColumnasySapProfParameter2read-writemandatoryDefines the X.3 parameter 2, Echo. This parameter provides for characters received from the start-stop mode DTE (user) to be transmitted back to the start-stop…
1.3.6.1.4.1.495.2.1.6.30.22.1.7ColumnasySapProfParameter3read-writemandatoryDefines the X.3 parameter 3, Selection of data forwarding character(s). This parameter allows the selection of defined sets of characters received from the sta…
1.3.6.1.4.1.495.2.1.6.30.22.1.8ColumnasySapProfParameter4read-writemandatoryDefines the X.3 parameter 4, Selection of idle timer delay, in tenths of a second. This parameter allows the selection of the duration of an interval between s…
1.3.6.1.4.1.495.2.1.6.30.22.1.9ColumnasySapProfParameter5read-writemandatoryDefines the X.3 parameter 5, Ancillary device control. This parameter allows for flow control between the PAD and the start-stop mode DTE (user). Options: 0: N…
1.3.6.1.4.1.495.2.1.6.30.22.1.10ColumnasySapProfParameter6read-writemandatoryDefines the X.3 parameter 6, Control of PAD service signals and PAD command signals. This parameter provides the start-stop mode DTE (user) with the ability to…
1.3.6.1.4.1.495.2.1.6.30.22.1.11ColumnasySapProfParameter7read-writemandatoryDefines the X.3 parameter 7, Selection of operation of the PAD on receipt of a break signal from the start-stop mode DTE. This parameter allows the selection o…
1.3.6.1.4.1.495.2.1.6.30.22.1.12ColumnasySapProfParameter8read-writemandatoryDefines the X.3 parameter 8, Discard output. This parameter provides for a PAD to discard the content of user sequences in packets upon request rather than dis…
1.3.6.1.4.1.495.2.1.6.30.22.1.13ColumnasySapProfParameter9read-writemandatoryDefines the X.3 parameter 9, Padding after carriage return (CR). This parameter provides for the automatic insertion of padding characters by the PAD after a c…
1.3.6.1.4.1.495.2.1.6.30.22.1.14ColumnasySapProfParameter10read-writemandatoryDefines the X.3 parameter 10, Line folding. This parameter provides for the automatic insertion of graphic characters by the PAD in the character stream transm…
1.3.6.1.4.1.495.2.1.6.30.22.1.15ColumnasySapProfParameter11read-onlymandatoryDefines the X.3 parameter 11, Binary speed of start-stop mode DTE. Options: 0: 110 bit/s 1: 134.5 bit/s 2: 300 bit/s 3: 1200 bit/s 4: 600 bit/s 5: 75 bit/s 6: …
1.3.6.1.4.1.495.2.1.6.30.22.1.16ColumnasySapProfParameter12read-writemandatoryDefines the X.3 parameter 12, Flow control of the PAD. This parameter allows for flow control between the start-stop mode DTE (user) and the PAD. Options: 0: N…
1.3.6.1.4.1.495.2.1.6.30.22.1.17ColumnasySapProfParameter13read-writemandatoryDefines the X.3 parameter 13, Linefeed insertion after carriage return. This parameter allows for the automatic insertion of a linefeed character in the charac…
1.3.6.1.4.1.495.2.1.6.30.22.1.18ColumnasySapProfParameter14read-writemandatoryDefines the X.3 parameter 14, Padding after linefeed. This parameter provides for the automatic insertion of padding characters in the character stream transmi…
1.3.6.1.4.1.495.2.1.6.30.22.1.19ColumnasySapProfParameter15read-writemandatoryDefines the X.3 parameter 15, Editing. This parameter provides for character size delete, line delete and line display editing capabilities in the PAD command …
1.3.6.1.4.1.495.2.1.6.30.22.1.20ColumnasySapProfParameter16read-writemandatoryDefines the X.3 parameter 16, Character delete. Range of Values: 0 to 127 0 to126: One character from IA5 127: Character 7/15 (DEL) Default Value: 0 Configurat…
1.3.6.1.4.1.495.2.1.6.30.22.1.21ColumnasySapProfParameter17read-writemandatoryDefines the X.3 parameter 17, Line delete. Range of Values: 0 to 127 0 to 23: One character from the range of IA5 24: Character 1/8 (CAN) 25 to 127: One charac…
1.3.6.1.4.1.495.2.1.6.30.22.1.22ColumnasySapProfParameter18read-writemandatoryDefines the X.3 parameter 18, Line display. Range of Values: 0 to 127 0 to 17: One character from the range of IA5 18: Character 1/8 (DC2) 19 to 127: One chara…
1.3.6.1.4.1.495.2.1.6.30.22.1.23ColumnasySapProfParameter19read-writemandatoryDefines the X.3 parameter 19, Editing PAD service signals. This parameter provides the start-stop mode DTE (user) with the ability to decide whether or not edi…
1.3.6.1.4.1.495.2.1.6.30.22.1.24ColumnasySapProfParameter20read-writemandatoryDefines the X.3 parameter 20, Echo mask. This parameter allows selected defined sets of characters received from the start-stop mode DTE (user) not to be trans…
1.3.6.1.4.1.495.2.1.6.30.22.1.25ColumnasySapProfParameter21read-writemandatoryDefines the X.3 parameter 21, Parity treatment. This parameter allows the PAD to check parity in the data stream from the start-stop mode DTE (user) or generat…
1.3.6.1.4.1.495.2.1.6.30.22.1.26ColumnasySapProfParameter22read-writemandatoryDefines the X.3 parameter 22, Page wait. This parameter allows the PAD to suspend transmission of additional characters to the start-stop mode DTE (user) after…
1.3.6.1.4.1.495.2.1.6.30.22.1.27ColumnasySapProfParameter23read-writemandatoryDefines parameter 23 (extension to X.3), Receive parity type. Options: 0: Parity disable 1: Even parity 2: Odd parity 3: Space parity 4: Mark parity Default Va…
1.3.6.1.4.1.495.2.1.6.30.22.1.28ColumnasySapProfParameter24read-writemandatoryDefines parameter 24 (extension to X.3), Transmit parity type. Options: 0: Parity disable 1: Even parity 2: Odd parity 3: Space parity 4: Mark parity Default V…
1.3.6.1.4.1.495.2.1.6.30.22.1.29ColumnasySapProfParameter25read-writemandatoryDefines parameter 25 (extension to X.3), Flow control on character to PAD. Range of Values: 0 to 127 0 to 18: One character from the range of IA5 19: DC3 20 to…
1.3.6.1.4.1.495.2.1.6.30.22.1.30ColumnasySapProfParameter26read-writemandatoryDefines parameter 26 (extension to X.3), Flow control off character to PAD. Range of Values: 0 to 127 0 to 16: One character from the range of IA5 17 = DC1 18 …
1.3.6.1.4.1.495.2.1.6.30.22.1.31ColumnasySapProfParameter27read-writemandatoryDefines parameter 27 (extension to X.3), Flow control on character to ancillary device. Range of Values: 0 to 127 Note: 0 to 18: One character from the range o…
1.3.6.1.4.1.495.2.1.6.30.22.1.32ColumnasySapProfParameter28read-writemandatoryDefines parameter 28 (extension to X.3), Flow control off character to ancillary device. Range of Values: 0 to 127 0 to 16: One character from the range of IA5…
1.3.6.1.4.1.495.2.1.6.30.23TableasyDteTablenot-accessiblemandatoryA table containing the DTE X.28 Selection command objects for each defined 'abbreviated address'.
1.3.6.1.4.1.495.2.1.6.30.23.1RowasyDteEntrynot-accessiblemandatoryThe objects for a specific DTE X.28 Selection entry.
1.3.6.1.4.1.495.2.1.6.30.23.1.1ColumnasyDteNumberread-onlymandatoryIdentifies the DTE X.28 Selection entry by a unique numerical value.
1.3.6.1.4.1.495.2.1.6.30.23.1.2ColumnasyDteRowStatusread-writemandatoryIndicates whether this specific entry is configured within the MIB. Entries (rows) may be created by setting this object value to 'valid', or deleted by changi…
1.3.6.1.4.1.495.2.1.6.30.23.1.3ColumnasyDteAliasread-writemandatoryIdentifies the DTE entry by a textual name. Names are unique per service access point. Note: Dte alias (name) must be preceded by a '.' (period) when used in a…
1.3.6.1.4.1.495.2.1.6.30.23.1.5ColumnasyDteCalledAddressread-writemandatoryDefines the network address of a remote device for this DTE entry. Allowable values: 1 to 15 numerical digits.
1.3.6.1.4.1.495.2.1.6.30.23.1.6ColumnasyDteFacilityFieldread-writemandatoryDefines the facility codes and parameters requires for the X.28 Selection command for this DTE entry. The facility codes and parameters must be entered as defi…
1.3.6.1.4.1.495.2.1.6.30.23.1.7ColumnasyDteUserDataFieldread-writemandatoryDefines the user data field of the X.28 Selection command for this DTE entry. A value of nul string (blank) means no user data.
1.3.6.1.4.1.495.2.1.6.30.23.1.8ColumnasyDteX3Profileread-writemandatoryDefines the X.3 Profile number for a specific set of X.3 parameters. The Async layer will initialize its SAP to this X.3 Profile before establishing a logical …
Type Definitions
NameSyntaxStatusDescription
DteIndexINTEGER (1..255)
PacketSizeINTEGER { bytes16 (4), bytes32 (5), bytes64 (6), bytes128 (7), bytes256 (8), bytes512 (9), bytes1024 (10), bytes2048 (11), bytes4096 (12) }
ProfIndexINTEGER (1..255)
YesNoINTEGER { no (1), yes (2) }