CXMCPRT-MIB
161 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.495.2.1.1.1 | NodecxMcPrt | |||
| 1.3.6.1.4.1.495.2.1.1.1.1 | NodecxMcPrtGlobal | |||
| 1.3.6.1.4.1.495.2.1.1.1.1.1 | ScalarcxMcPrtGlobalConsoleRate | read-write | optional | The front panel console rate for the HC600. Range of Values: 300-19 200 Default Value: 19 200 |
| 1.3.6.1.4.1.495.2.1.1.1.1.2 | ScalarcxMcPrtGlobalResetStat | read-write | optional | Resets all statistics. Options: no(1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.1.3 | ScalarcxMcPrtGlobalStationId | read-write | optional | The local station identification. No space allowed in write. |
| 1.3.6.1.4.1.495.2.1.1.1.2 | TablecxMcPrtCfgTable | not-accessible | mandatory | cx Port Station Configuration Table. |
| 1.3.6.1.4.1.495.2.1.1.1.2.1 | RowcxMcPrtCfgEntry | not-accessible | mandatory | cx Port Station Configuration Entry gives the state of the configuration associated to a particular port. |
| 1.3.6.1.4.1.495.2.1.1.1.2.1.1 | ColumncxMcPrtCfgPortIndex | read-only | mandatory | Identifies the port by a numerical value. Range of Values: 1-4 |
| 1.3.6.1.4.1.495.2.1.1.1.2.1.2 | ColumncxMcPrtCfgDriverUsed | read-write | mandatory | Specifies the port driver used. The driver is associated with a numerical value that identify one of the tables below the object identifier; cxMcPrtDriver for … |
| 1.3.6.1.4.1.495.2.1.1.1.2.1.3 | ColumncxMcPrtCfgReinitPort | read-write | optional | Activate the planned configurations of the indexed port. Options: no (1) yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.2.1.4 | ColumncxMcPrtCfgUpdated | read-only | mandatory | The status of the configuration of a port. Options: no (1) yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3 | TablecxMcPrtStatTable | not-accessible | mandatory | cx Port Station Statistic Table. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1 | RowcxMcPrtStatEntry | not-accessible | mandatory | cx Port Station Statistic Entry gives the state of the counters associated with a particular port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.1 | ColumncxMcPrtStatPortNumber | read-only | mandatory | Indicates the port number of the statistics. Range of Values: 1-4 |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.2 | ColumncxMcPrtStatRts | read-only | mandatory | Indicates the current state of the Request to Send signal. Options: off (1) on (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.3 | ColumncxMcPrtStatDtr | read-only | mandatory | Indicates the current state of the Data Terminal Ready signal. Options: off (1) on (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.4 | ColumncxMcPrtStatDsr | read-only | mandatory | Indicates the current state of the Data Set Ready signal. Options: off (1) on (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.5 | ColumncxMcPrtStatDcd | read-only | mandatory | Indicates the current state of the Data Carrier Detect signal. Options: off (1) on (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.6 | ColumncxMcPrtStatCts | read-only | mandatory | Indicates the current state of the Clear to Send signal. Options: off (1) on (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.7 | ColumncxMcPrtStatCntMsgTx | read-only | mandatory | Indicates the number of frames transmitted on the specified port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.8 | ColumncxMcPrtStatCntMsgRx | read-only | mandatory | Indicates the number of frames received on the specified port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.9 | ColumncxMcPrtStatCntReinit | read-only | mandatory | Indicates the number of times that the specified port has reinitialized. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.10 | ColumncxMcPrtStatCntFlowCtrlTx | read-only | mandatory | Indicates the number of times that the specified port has performed output flow control. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.11 | ColumncxMcPrtStatCntFlowCtrlRx | read-only | mandatory | Indicates the number of times that the specified port has performed input flow control. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.12 | ColumncxMcPrtStatCntErrTx | read-only | mandatory | Indicates the number of bad frames transmitted on the specified port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.13 | ColumncxMcPrtStatCntErrRx | read-only | mandatory | Indicates the number of bad frames received on the specified port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.14 | ColumncxMcPrtStatCntConnect | read-only | mandatory | Indicates the number of connections for the specified port. The number of connections is equal to the number of times that the DTR modem signal changed from OF… |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.15 | ColumncxMcPrtStatCntChrDecomp | read-only | mandatory | Indicates the number of characters transmitted on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.16 | ColumncxMcPrtStatCntChrComp | read-only | mandatory | Indicates the number of characters received on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.17 | ColumncxMcPrtStatCntBitDecomp | read-only | mandatory | Indicates the number of bits transmitted on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.18 | ColumncxMcPrtStatCntBitComp | read-only | mandatory | Indicates the number of bits received on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.19 | ColumncxMcPrtStatStation | read-only | mandatory | Indicates the station that the port is using to transmit and receive data. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.20 | ColumncxMcPrtStatRoute | read-only | mandatory | Indicates the route of the station that the port is using. |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.21 | ColumncxMcPrtStatHwInterface | read-only | mandatory | Indicates whether the hardware port interface is DCE or DTE. The value depends on the I/O hardware. Options: dce (1) dte (2) |
| 1.3.6.1.4.1.495.2.1.1.1.3.1.22 | ColumncxMcPrtStatTimeTicks | read-only | mandatory | Indicates the number of milliseconds since the last reset for the current station. |
| 1.3.6.1.4.1.495.2.1.1.1.4 | NodecxMcPrtPath | |||
| 1.3.6.1.4.1.495.2.1.1.1.4.1 | ScalarcxMcPrtPathStationPri | read-write | mandatory | The primary port station. Range of Values: 1-16 Default Value: 1 |
| 1.3.6.1.4.1.495.2.1.1.1.4.2 | ScalarcxMcPrtPathRoutePri | read-write | mandatory | The primary route. Range of Values: 1-64 Default Value: 1 |
| 1.3.6.1.4.1.495.2.1.1.1.4.3 | ScalarcxMcPrtPathStationScd | read-write | mandatory | The secondary port station. Range of Values: 1-16 Default Value: 2 |
| 1.3.6.1.4.1.495.2.1.1.1.4.4 | ScalarcxMcPrtPathRouteScd | read-write | mandatory | The secondary route. Range of Values: 1-64 Default Value: 2 |
| 1.3.6.1.4.1.495.2.1.1.1.5 | NodecxMcPrtDriver | |||
| 1.3.6.1.4.1.495.2.1.1.1.5.1 | TablecxMcPrtBopTable | not-accessible | mandatory | cx Port Station MC600 & HC600 Bop Driver Table. |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1 | RowcxMcPrtBopEntry | not-accessible | mandatory | cx Port Station MC600 & HC600 Bop Driver Entry gives the state of the variables associated to the Bit Oriented Protocol. |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.1 | ColumncxMcPrtBopPortUsed | read-only | mandatory | Indicates the current port number that is used by the BOP driver. Range of Values: 1-4 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.2 | ColumncxMcPrtBopPortStatus | read-write | mandatory | Indicates whether the port is enabled or disabled. Options: disable (1) enable (2) Default Value: disable (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.3 | ColumncxMcPrtBopComRate | read-write | mandatory | Indicates the port communication rates. Range of Values: HC600: 9600-2048000 MC600: 110-128000 Default Value: HC600: 56 000, MC600: 9600 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.4 | ColumncxMcPrtBopUseLnkErrPassthro | read-write | mandatory | Indicates the link error passthrough state on the port. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.5 | ColumncxMcPrtBopInterface | read-write | mandatory | Indicates whether the port interface is DTE or DCE. Options: dce (1) dte (2) Default Value: dce (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.6 | ColumncxMcPrtBopRtsDcdModemCtrl | read-write | mandatory | Use the RTS or DCD modem control on the port. Options: on (1) vary (2) Default Value: on (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.7 | ColumncxMcPrtBopUseRtsDcdCndDataTx | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the presence of data in output queue. Options: no (1) yes (2) Default Va… |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.8 | ColumncxMcPrtBopUseRtsDcdCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.9 | ColumncxMcPrtBopUseRtsDcdCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.10 | ColumncxMcPrtBopDtrCtsModemCtrl | read-write | mandatory | Use the DTR or CTS modem control on the port. Options: on (1) vary (2) Default Value: on (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.11 | ColumncxMcPrtBopUseDtrCtsCndRts | read-write | mandatory | Use the state of the CTS modem control when the port selected is conditioned by the local RTS. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.12 | ColumncxMcPrtBopUseDtrCtsCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.13 | ColumncxMcPrtBopUseDtrCtsCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.14 | ColumncxMcPrtBopLimitBeforeOut | read-write | mandatory | The limit before activation of output for the port. Range of Values: HC600: 2-100, MC600: 5-4000 Default Value: HC600: 5, MC600: 15 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.15 | ColumncxMcPrtBopUseOutCndCtsDtrOn | read-write | mandatory | Use the output enable on CTS or DTR modem control for the port. Options: no(1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.16 | ColumncxMcPrtBopUseInCndDcdRtsOn | read-write | mandatory | Use the input enable on DCD or RTS modem control for the port. Options: no(1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.17 | ColumncxMcPrtBopSyncMode | read-write | mandatory | The clock synchronization for the port. Options: normal (1) extern (2) Default Value: normal (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.18 | ColumncxMcPrtBopDataLifetime | read-write | mandatory | The data lifetime in millisecond for the port. Range of Values: 1-60000 Default Value: 2000 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.19 | ColumncxMcPrtBopUseClockSync | read-write | mandatory | The clocks synchronization on the port. Options: no(1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.20 | ColumncxMcPrtBopUseFlowCtrlClock | read-write | mandatory | Use the flow control by clocks for the synchronous port. Options: no(1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.21 | ColumncxMcPrtBopFlowCtrlRate | read-write | mandatory | The flow control rate of the synchronous port. Range of Values: HC600: 300-5609, MC600: 110-9600 Default Value: HC600: 2400. MC600: 300 HC600 DEFVAL { 2400 } M… |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.22 | ColumncxMcPrtBopLimitOutFlowCtrl | read-write | mandatory | The limit before output flow control of the synchronous port. Range of Values: HC600: 1-100, MC600: 0-4000 Default Value: HC600: 15, MC600: 3 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.23 | ColumncxMcPrtBopLimitInFlowCtrl | read-write | mandatory | The overflow limit before input flow control of the synchronous port. Ranges of Values: HC600: 1-100, MC600: 0-4000 Default Value: HC600: 32, MC600: 512 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.24 | ColumncxMcPrtBopCoding | read-write | mandatory | The coding on the port for bit-oriented protocols. Options: nrz (1) nrzi (2) Default Value: nrz (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.25 | ColumncxMcPrtBopOutIdleState | read-write | mandatory | The output idle state of the synchronous port. Options: flag (1) mark (2) Default Value: flag (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.26 | ColumncxMcPrtBopDelayBeforeIdle | read-write | mandatory | The delay between frames before idle for the port. Range of Values: 0-2000 Default Value: 0 |
| 1.3.6.1.4.1.495.2.1.1.1.5.1.1.27 | ColumncxMcPrtBopOutPreambleLng | read-write | mandatory | The output preamble length of the synchronous port. Options: zero (1): HC600 or MC600 one (2): HC600 only two (3): HC600 only four (4): HC600 only eight (5): H… |
| 1.3.6.1.4.1.495.2.1.1.1.5.2 | TablecxMcPrtAsyTable | not-accessible | mandatory | cx Port Station MC600 Asy Driver Table. |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1 | RowcxMcPrtAsyEntry | not-accessible | mandatory | cx Port Station MC600 Asy Driver Entry gives the state of the variables associated to the Asynchronous Protocol. |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.1 | ColumncxMcPrtAsyPortUsed | read-only | mandatory | The current port number that is used by the ASY driver. |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.2 | ColumncxMcPrtAsyPortStatus | read-write | mandatory | The port status for enabling or disabling the port. Options: disable (1) enable (2) Default Value: disable (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.3 | ColumncxMcPrtAsyComRate | read-write | mandatory | The port communication rates. Range of Values: 110-128000 Default Value: 9600 |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.4 | ColumncxMcPrtAsyUseLnkErrPassthro | read-write | mandatory | Use the link error pass through on the port. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.5 | ColumncxMcPrtAsyInterface | read-write | mandatory | The port interface to DTE or DCE. Options: dce (1) dte (2) Default Value: dce (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.6 | ColumncxMcPrtAsyRtsDcdModemCtrl | read-write | mandatory | Use the RTS or DCD modem control on the port. Options: on (1) vary (2) Default Value: on (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.7 | ColumncxMcPrtAsyUseRtsDcdCndDataTx | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the presence of data in output queue. Options: no (1) yes (2) Default Va… |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.8 | ColumncxMcPrtAsyUseRtsDcdCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.9 | ColumncxMcPrtAsyUseRtsDcdCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.10 | ColumncxMcPrtAsyDtrCtsModemCtrl | read-write | mandatory | Use the DTR or CTS modem control on the port. Options: on (1) vary (2) Default Value: on (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.11 | ColumncxMcPrtAsyUseDtrCtsCndRts | read-write | mandatory | Use the state of the CTS modem control when the port selected is conditioned by the local RTS. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.12 | ColumncxMcPrtAsyUseDtrCtsCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.13 | ColumncxMcPrtAsyUseDtrCtsCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.14 | ColumncxMcPrtAsyLimitBeforeOut | read-write | mandatory | The limit before activation of output for the port. Range of Values: 1-100 Default Value: 15 |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.15 | ColumncxMcPrtAsyOutCndCtsDtrOn | read-write | mandatory | Use the output enable on CTS or DTR modem control for the port. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.16 | ColumncxMcPrtAsyInCndDcdRtsOn | read-write | mandatory | Use the input enable on DCD or RTS modem control for the port. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.17 | ColumncxMcPrtAsySyncMode | read-write | mandatory | The clock synchronization for the port. Options: normal (1) extern (2) Default Value: normal (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.18 | ColumncxMcPrtAsyUseDataLifeLimited | read-write | mandatory | Use the data lifetime limited on the asynchronous port. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.19 | ColumncxMcPrtAsyDataLifetime | read-write | mandatory | The data lifetime in milliseconds for the port. Range of Values: 1-60000 Default Value: 2000 |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.20 | ColumncxMcPrtAsyOutFlowCtrl | read-write | mandatory | The output flow control of the asynchronous port. Options: disable (1) xonxoff (2) ctsdtr (3) Default Value: xonxoff (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.21 | ColumncxMcPrtAsyInFlowCtrl | read-write | mandatory | The input flow control of the asynchronous port. Options: disable (1) xonxoff (2) ctsdtr (3) Default Value: xonxoff (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.22 | ColumncxMcPrtAsyXonChr | read-write | mandatory | The XON character value of the asynchronous port. Range of Values: 0-255 Default Value: 17 |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.23 | ColumncxMcPrtAsyXoffChr | read-write | mandatory | The XOFF character value of the asynchronous port. Range of Values: 0-255 Default Value: 19 |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.24 | ColumncxMcPrtAsyNbBitPerChr | read-write | mandatory | The number of bits per character on the port. Options: six (1) seven (2) eight (3) Default Value: eight (3) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.25 | ColumncxMcPrtAsyParity | read-write | mandatory | The parity on the port. Options: none (1) even (2) odd (3) Default Value: none (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.26 | ColumncxMcPrtAsyNbStopBit | read-write | mandatory | The number of stop bits per character on the asynchronous port. Options: one (1) onehalf (2) two (3) Default Value: one (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.27 | ColumncxMcPrtAsyUseFlushOutChr | read-write | mandatory | The flush output on specific character on the asynchronous port. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.2.1.28 | ColumncxMcPrtAsyFlushOutChr | read-write | mandatory | The flush character on the asynchronous port. Range of Values: 0-255 Default Value: 127 |
| 1.3.6.1.4.1.495.2.1.1.1.5.3 | TablecxMcPrtCopTable | not-accessible | mandatory | cx Port Station MC600 Cop Driver Table. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1 | RowcxMcPrtCopEntry | not-accessible | mandatory | cx Port Station MC600 Cop Driver Entry gives the state of the variables associated to the Character Oriented Protocol. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.1 | ColumncxMcPrtCopPortUsed | read-only | mandatory | The current port number that is used by the COP Driver. Range of Values: 1-4 |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.2 | ColumncxMcPrtCopPortStatus | read-write | mandatory | The port status for enabling or disabling the port. Options: disable (1) enable (2) Default Value: disable (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.3 | ColumncxMcPrtCopComRate | read-write | mandatory | The port communication rates. Range of Values: 110-128000 Default Value: 9600 |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.4 | ColumncxMcPrtCopUseLnkErrPassthro | read-write | mandatory | Use the link error pass through on the port. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.5 | ColumncxMcPrtCopInterfaceType | read-write | mandatory | The port interface type: DTE or DCE. Options: dce (1) dte (2) Default: dce (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.6 | ColumncxMcPrtCopRtsDcdModemCtrl | read-write | mandatory | Use the RTS or DCD modem control on the port. Options on (1) vary (2) Default Value: on (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.7 | ColumncxMcPrtCopUseRtsDcdCndDataTx | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the presence of data in output queue. Options: no (1) yes (2) Default Va… |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.8 | ColumncxMcPrtCopUseRtsDcdCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.9 | ColumncxMcPrtCopUseRtsDcdCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.10 | ColumncxMcPrtCopDtrCtsModemCtrl | read-write | mandatory | Use the DTR or CTS modem control on the port. Options: on (1) vary (2) Default Value: on (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.11 | ColumncxMcPrtCopUseDtrCtsCndRts | read-write | mandatory | Use the state of the CTS modem control when the port selected is conditioned by the local RTS. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.12 | ColumncxMcPrtCopUseDtrCtsCndLnk | read-write | mandatory | Use the the RTS or DCD modem control when the port selected is conditioned by the main link status. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.13 | ColumncxMcPrtCopUseDtrCtsCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. Options: no (1) yes (2) Default Value: yes (2) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.14 | ColumncxMcPrtCopLimitBeforeOut | read-write | mandatory | The limit before activation of output for the port. Range of Values: 5-4000 Default Value: 15 |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.15 | ColumncxMcPrtCopUseOutCndCtsDtrOn | read-write | mandatory | The output enable on CTS or DTR modem control for the port. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.16 | ColumncxMcPrtCopUseInCndDcdRtsOn | read-write | mandatory | The input enable on DCD or RTS modem control for the port. Options: no (1) yes (2) Default Value: no (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.17 | ColumncxMcPrtCopSyncMode | read-write | mandatory | The clock synchronization for the port. Options: normal (1) extern (2) Default Value: normal (1) |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.18 | ColumncxMcPrtCopDataLifetime | read-write | mandatory | The data lifetime in milliseconds for the port. Range of Values: 1-60000 |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.19 | ColumncxMcPrtCopUseClockSync | read-write | mandatory | The clocks synchronization on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.20 | ColumncxMcPrtCopUseFlowCtrlClock | read-write | mandatory | The use of flow control by clocks of the synchronous port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.21 | ColumncxMcPrtCopFlowCtrlRate | read-write | mandatory | The use of flow control rate of the synchronous port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.22 | ColumncxMcPrtCopLimitOutFlowCtrl | read-write | mandatory | The limit before output flow control of the synchronous port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.23 | ColumncxMcPrtCopLimitInFlowCtrl | read-write | mandatory | The overflow limit before input flow control for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.24 | ColumncxMcPrtCopOutIdleState | read-write | mandatory | The output idle state for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.25 | ColumncxMcPrtCopNbBitPerChr | read-write | mandatory | The number of bits per character on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.26 | ColumncxMcPrtCopParity | read-write | mandatory | The parity on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.27 | ColumncxMcPrtCopSyncChrOne | read-write | mandatory | The synchronization character number one for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.28 | ColumncxMcPrtCopSyncChrTwo | read-write | mandatory | The synchronization character number two for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.29 | ColumncxMcPrtCopNbSyncChr | read-write | mandatory | The number of synchronization character for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.30 | ColumncxMcPrtCopUseDesyncChr | read-write | mandatory | Use the desynchronization character on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.31 | ColumncxMcPrtCopDesyncChr | read-write | mandatory | The desynchronization character for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.32 | ColumncxMcPrtCopNbDesyncChr | read-write | mandatory | The number of desynchronization character for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.33 | ColumncxMcPrtCopUseDesyncRtsFall | read-write | mandatory | Use the desynchronization on RTS fall on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.3.1.34 | ColumncxMcPrtCopBitSense | read-write | mandatory | The bit sense on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4 | TablecxMcPrtBsyTable | not-accessible | mandatory | cx Port Station MC600 Bsy Driver Table. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1 | RowcxMcPrtBsyEntry | not-accessible | mandatory | cx Port Station MC600 Bsy Driver Entry gives the state of the variables associated to the Bi-synchronous Protocol. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.1 | ColumncxMcPrtBsyPortUsed | read-only | mandatory | The current port number that is used by the BSY Driver. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.2 | ColumncxMcPrtBsyPortStatus | read-write | mandatory | The port status for enabling or disabling the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.3 | ColumncxMcPrtBsyComRate | read-write | mandatory | The port communication rates. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.4 | ColumncxMcPrtBsyUseLnkErrPassthro | read-write | mandatory | Use the link error pass through on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.5 | ColumncxMcPrtBsyInterface | read-write | mandatory | The port interface type: DTE or DCE. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.6 | ColumncxMcPrtBsyRtsDcdModemCtrl | read-write | mandatory | Use the RTS or DCD modem control on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.7 | ColumncxMcPrtBsyUseRtsDcdCndDataTx | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the presence of data in output queue. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.8 | ColumncxMcPrtBsyUseRtsDcdCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.9 | ColumncxMcPrtBsyUseRtsDcdCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.10 | ColumncxMcPrtBsyDtrCtsModemCtrl | read-write | mandatory | Use the DTR or CTS modem control on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.11 | ColumncxMcPrtBsyUseDtrCtsCndRts | read-write | mandatory | Use the state of the CTS modem control when the port selected is conditioned by the local RTS. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.12 | ColumncxMcPrtBsyUseDtrCtsCndLnk | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the main link status. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.13 | ColumncxMcPrtBsyUseDtrCtsCndRem | read-write | mandatory | Use the state of the RTS or DCD modem control when the port selected is conditioned by the remote DCD or RTS. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.14 | ColumncxMcPrtBsyLimitBeforeOut | read-write | mandatory | The limit before activation of output for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.15 | ColumncxMcPrtBsyUseOutCndCtsDtrOn | read-write | mandatory | Use the output enable on CTS or DTR modem control for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.16 | ColumncxMcPrtBsyUseInCndDcdRtsOn | read-write | mandatory | Use the input enable on DCD or RTS modem control for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.17 | ColumncxMcPrtBsySyncMode | read-write | mandatory | The clock synchronization for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.18 | ColumncxMcPrtBsyDataLifetime | read-write | mandatory | The data lifetime in milliseconds for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.19 | ColumncxMcPrtBsyChrSet | read-write | mandatory | The character set on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.20 | ColumncxMcPrtBsyParity | read-write | mandatory | The parity on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.21 | ColumncxMcPrtBsyBlkChkChr | read-write | mandatory | The block check character on the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.22 | ColumncxMcPrtBsyNbSyncChr | read-write | mandatory | The number of synchronization character for the port. |
| 1.3.6.1.4.1.495.2.1.1.1.5.4.1.23 | ColumncxMcPrtBsyMaxFrameSize | read-write | mandatory | The maximum frame size for the port. |