No module-level DESCRIPTION found.
Imported Objects
ChrComIfifTable-MIBchrComIfifIndex
Chromatis-MIBchrComIfOptics
ChrTyp-MIB MISSINGTruthValue
LaserActivation-MIB MISSINGLaserActivation
OMSControlTypes-MIB MISSINGOMSControlType
OpaAPSDSTATE-MIB MISSINGAPSDSTATE
OTSControlTypes-MIB MISSINGAgcppc
SNMPv2-SMICounter32 Integer32 OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.3695.1.2.3.4TablechrComIfOpticsOMS-SRCTablenot-accessiblecurrentThe OMS is managed only for the Ring side of the Metropolis Network (not for the Trib side).
1.3.6.1.4.1.3695.1.2.3.4.1RowchrComIfOpticsOMS-SRCEntrynot-accessiblecurrent
1.3.6.1.4.1.3695.1.2.3.4.1.1ColumnchrComIfOpticsOmsSrcNumOfPrecedingOPAsread-writecurrentNumber of OPAs prior to the respective ADOM/OMDM.
1.3.6.1.4.1.3695.1.2.3.4.1.2ColumnchrComIfOpticsOmsSrcDWDMOutputPowerread-onlycurrentThe optical power in the DWDM band (without the 1310nm channel) at the output of the module.
1.3.6.1.4.1.3695.1.2.3.4.1.3ColumnchrComIfOpticsOmsSrcDWDMLOOPThrread-writecurrentThis is a threshold on OMS-SRC DWDM output Power, indicating the existence of power in the DWDM band at the output of the module.
1.3.6.1.4.1.3695.1.2.3.4.1.4ColumnchrComIfOpticsOmsSrcDWDMSafetyThrread-writecurrentThis is a threshold on OMS-SRC DWDM output Power, indicating the safety power level in the DWDM band at the output of the ADOM/OMDM.
1.3.6.1.4.1.3695.1.2.3.4.1.5ColumnchrComIfOpticsOmsSrcTx1310Powerread-onlycurrentThe optical power monitored on 1310 transmit point.
1.3.6.1.4.1.3695.1.2.3.4.1.6ColumnchrComIfOpticsOmsSrcTxLambdaPowerread-onlycurrentThe optical power monitored on Lambda transmit point.
1.3.6.1.4.1.3695.1.2.3.4.1.7ColumnchrComIfOpticsOmsSrcADOMPwrControlModeread-writecurrentDefines ADOM module operational mode.
1.3.6.1.4.1.3695.1.2.3.4.1.8ColumnchrComIfOpticsOmsSrcExpectedAddedLambdaPowerread-writecurrentThe expected added Lambda channel power after Attenuation (reflected to module out).
1.3.6.1.4.1.3695.1.2.3.4.1.9ColumnchrComIfOpticsOmsSrcActualAddedPowerread-onlycurrentMonitored added lambda channel power after Attenuation (reflected to module out).
1.3.6.1.4.1.3695.1.2.3.4.1.10ColumnchrComIfOpticsOmsSrcExpectedAddedLambdaPowerOffsetread-writecurrentThe expected added to dropped lambda channel power offset.
1.3.6.1.4.1.3695.1.2.3.4.1.11ColumnchrComIfOpticsOmsSrcActualAddedPowerOffsetread-onlycurrentThe Actual added to dropped lambda channel power offset.
1.3.6.1.4.1.3695.1.2.3.4.1.12ColumnchrComIfOpticsOmsSrcExpectedAddedChannelAttenuationread-writecurrentThe expected Attenuation of added lambda channel
1.3.6.1.4.1.3695.1.2.3.4.1.13ColumnchrComIfOpticsOmsSrcActualAddedChannelAttenuationread-onlycurrent
1.3.6.1.4.1.3695.1.2.3.4.1.14ColumnchrComIfOpticsOmsSrcBackplaneAttenuatorLambdaread-writecurrentAttenuation in dB. Zero when no backplane Attenuator exists.
1.3.6.1.4.1.3695.1.2.3.4.1.15ColumnchrComIfOpticsOmsSrcBackplaneAttenuator1310read-writecurrentAttenuation in dB. Zero when no backplane Attenuator exists.
1.3.6.1.4.1.3695.1.2.3.4.1.16ColumnchrComIfOpticsOmsSrcTxLambdaLOOCThrread-onlycurrentLooc Threshold of transmitted lambda power.
1.3.6.1.4.1.3695.1.2.3.4.1.17ColumnchrComIfOpticsOmsSrcOCHSLOOCThrLambdaread-writecurrentA duplication of the OCH-S Looc Threshold.
1.3.6.1.4.1.3695.1.2.3.4.1.18ColumnchrComIfOpticsOmsSrcAddedLambdaLOOCThrread-writecurrentLooc Threshold of added lambda.
1.3.6.1.4.1.3695.1.2.3.4.1.19ColumnchrComIfOpticsOmsSrcTx1310LOOCThrread-onlycurrentLooc Threshold of transmitted 1310.
1.3.6.1.4.1.3695.1.2.3.4.1.20ColumnchrComIfOpticsOmsSrcOCHSLOOCThr1310read-writecurrentA duplication of the OCH-S Looc Threshold.
1.3.6.1.4.1.3695.1.2.3.4.1.21ColumnchrComIfOpticsOmsSrcPostOPADWDMInputPowerread-onlycurrentThe optical power in the DWDM band (without the 1310nm channel) at the input of the pre-OPA.
1.3.6.1.4.1.3695.1.2.3.4.1.22ColumnchrComIfOpticsOmsSrcPostOPAInputLOOCThrread-onlycurrentThis is a threshold on OMS-SRC post-OPA DWDM input Power, indicating Loss Of Optical DWDM Channels at the input to the Post-OPA.
1.3.6.1.4.1.3695.1.2.3.4.1.23ColumnchrComIfOpticsOmsSrcParamForPostOPAInputLOOCThrread-writecurrentInput parameter for calculating OMS-SRC post-OPA input LOOC threshold.
1.3.6.1.4.1.3695.1.2.3.4.1.24ColumnchrComIfOpticsOmsSrcPostOPAInputLOOPThrread-writecurrentThis is a threshold on OMS-SRC post-OPA DWDM input Power, indicating Loss Of Optical DWDM power at the input to the Post-OPA.
1.3.6.1.4.1.3695.1.2.3.4.1.25ColumnchrComIfOpticsOmsSrcPostOPAModeOfOperationread-writecurrent� (Automatic Gain Control AGC  Default) � Automatic Pump Power Control  PPC
1.3.6.1.4.1.3695.1.2.3.4.1.26ColumnchrComIfOpticsOmsSrcPostOPAExpectedGainread-writecurrentThe Desired gain of the post OPA module (input to output optical DWDM power).
1.3.6.1.4.1.3695.1.2.3.4.1.27ColumnchrComIfOpticsOmsSrcPostOPAActualGainread-onlycurrentThe Actual gain of the post OPA (input to output optical DWDM power).
1.3.6.1.4.1.3695.1.2.3.4.1.28ColumnchrComIfOpticsOmsSrcPostOPAExpectedPumpPowerread-writecurrentThe Desired EDFA pump power of post-OPA module.
1.3.6.1.4.1.3695.1.2.3.4.1.29ColumnchrComIfOpticsOmsSrcPostOPAActualPumpPowerread-onlycurrentThe Actual EDFA pump power of post-OPA module.
1.3.6.1.4.1.3695.1.2.3.4.1.30ColumnchrComIfOpticsOmsSrcPostOPAAPSDStateread-writecurrentControlling the Automatic Pump Shut Down (APSD) mode.
1.3.6.1.4.1.3695.1.2.3.4.1.31ColumnchrComIfOpticsOmsSrcPostOPAPumpRestartActionread-writecurrentEnables remote operation which is equivalent to the restart push button of the post-OPA.
1.3.6.1.4.1.3695.1.2.3.4.1.32ColumnchrComIfOpticsOmsSrcPostOPAPumpLaserActivationStatusread-onlycurrentPost OPA Pump Laser ON/OFF Actual status.
1.3.6.1.4.1.3695.1.2.3.4.1.33ColumnchrComIfOpticsOmsSrcOPAExpectedAttenuatorAttenuationread-writecurrentThe expected Attenuation of the attenuator at the output of the OPA
1.3.6.1.4.1.3695.1.2.3.4.1.34ColumnchrComIfOpticsOmsSrcOPAActualAttenuatorAttenuationread-onlycurrentThe actual Attenuation of the attenuator at the output of the OPA
1.3.6.1.4.1.3695.1.2.3.4.1.35ColumnchrComIfOpticsOmsSrcPostOPAPumpTempread-onlycurrentThe temperature of the module.
1.3.6.1.4.1.3695.1.2.3.4.1.36ColumnchrComIfOpticsOmsSrcPostOPAPumpBiasCurrentread-onlycurrent
1.3.6.1.4.1.3695.1.2.3.4.1.37ColumnchrComIfOpticsAlarmVectorread-onlycurrent