DASAN-GFAST-MIB
629 objects
The MIB module to describe G-FAST.
Imported Objects
| DASAN-SMI | dasanEvents dasanMgmt |
| IF-MIB | ifIndex |
| SNMPv2-SMI | Counter32 Counter64 Integer32 IpAddress MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6296.9.102 | IdentitygFastMIB | The MIB module to describe G-FAST. | ||
| 1.3.6.1.4.1.6296.9.102.1 | NodegfastGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.0 | NodegfastNotifPrefix | |||
| 1.3.6.1.4.1.6296.9.102.1.1 | NodegfastDeviceGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.1.1 | ScalargfastDevTddMf | read-only | current | Specifies the gfast number of symbols in a TDD frame. |
| 1.3.6.1.4.1.6296.9.102.1.1.2 | ScalargfastDevTddMds | read-write | current | Specifies the gfast number of DS symbols in a TDD frame. |
| 1.3.6.1.4.1.6296.9.102.1.1.3 | ScalargfastDevReboot | read-write | current | Controls the Gfast DSP to reboot. |
| 1.3.6.1.4.1.6296.9.102.1.1.4 | ScalargfastDevLineMode | read-write | current | Controls the Gfast Line Mode. |
| 1.3.6.1.4.1.6296.9.102.1.1.5 | ScalargfastDevSyslogRateChange | read-write | current | Specifies the gfast syslog rate-change bps. unit is Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.1.6 | ScalargfastDevAutoRateLimit | read-write | current | Specifies the gFastMIB System Port Auto Rate-Limit. |
| 1.3.6.1.4.1.6296.9.102.1.2 | NodegfastPortGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.2.1 | TablegfastPortTable | not-accessible | current | This table includes common attributes describing gFastMIB System Port Information. |
| 1.3.6.1.4.1.6296.9.102.1.2.1.1 | RowgfastPortEntry | not-accessible | current | An entry in gfastPortTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.1.1.1 | ColumngfastPortIndex | read-only | current | Specifies the gFastMIB System Port index. |
| 1.3.6.1.4.1.6296.9.102.1.2.1.1.2 | ColumngfastPortProfileID | read-only | current | Specifies the gFastMIB Profile ID. |
| 1.3.6.1.4.1.6296.9.102.1.2.1.1.3 | ColumngfastPortProfileName | read-only | current | Defines the Profile Name. |
| 1.3.6.1.4.1.6296.9.102.1.2.1.1.4 | ColumngfastPortAdminCommand | read-write | current | Controls the Gfast Port admin mode. |
| 1.3.6.1.4.1.6296.9.102.1.2.1.1.5 | ColumngfastPortRestartCommand | read-write | current | Controls the Gfast Port to restart. |
| 1.3.6.1.4.1.6296.9.102.1.2.2 | TablegfastPortStatusTable | not-accessible | current | The gfast port status table |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1 | RowgfastPortStatusEntry | not-accessible | current | an entry of the gfast port status table |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.1 | ColumngfastPortStatusState | read-only | current | Specifies the gfast Port's Status. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.2 | ColumngfastPortStatusUsLineBitRate | read-only | current | Specifies the gfast Port's Up Stream Line Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.3 | ColumngfastPortStatusDsLineBitRate | read-only | current | Specifies the gfast Port's Down Stream Line Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.4 | ColumngfastPortStatusAggregateDataBitRate | read-only | current | Specifies the gfast Port's Aggregate Data Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.5 | ColumngfastPortStatusUsDataBitRate | read-only | current | Specifies the gfast Port's Up Stream Data Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.6 | ColumngfastPortStatusDsDataBitRate | read-only | current | Specifies the gfast Port's Down Stream Data Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.7 | ColumngfastPortStatusUsSnrm | read-only | current | Specifies the gfast Port's Up Stream Signal to Noise Ratio Margin. Expressed in tenth of dB's |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.8 | ColumngfastPortStatusDsSnrm | read-only | current | Specifies the gfast Port's Down Stream Signal to Noise Ratio Margin. Expressed in tenth of dB's |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.9 | ColumngfastPortStatusUsOutputPower | read-only | current | Specifies the gfast Port's Up Stream Transmit Power. Expressed in tenth of dBm's |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.10 | ColumngfastPortStatusDsOutputPower | read-only | current | Specifies the gfast Port's Down Stream Transmit Power. Expressed in tenth of dBm's |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.11 | ColumngfastPortStatusUsActualInp | read-only | current | Specifies the gfast Port's Up Stream Actual INP aginst SHINE. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.12 | ColumngfastPortStatusDsActualInp | read-only | current | Specifies the gfast Port's Down Stream Actual INP aginst SHINE. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.13 | ColumngfastPortStatusUsActualInpRein | read-only | current | Specifies the gfast Port's Up Stream Actual INP aginst REIN. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.14 | ColumngfastPortStatusDsActualInpRein | read-only | current | Specifies the gfast Port's Down Stream Actual INP aginst REIN. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.15 | ColumngfastPortStatusLoopLength | read-only | current | Specifies the gfast Port's Estimated Loop Length. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.16 | ColumngfastPortStatusUpTime | read-only | current | Specifies the gfast Port's Showtime Up Time (sec). |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.17 | ColumngfastPortStatusLPR | read-only | current | Specifies the gfast Port's LPR status. |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.18 | ColumngfastPortStatusUsAutoBitRate | read-only | current | Specifies the gfast Port's Up Stream Auto Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.19 | ColumngfastPortStatusDsAutoBitRate | read-only | current | Specifies the gfast Port's Down Stream Auto Bit Rate. Unit is 1Kbps |
| 1.3.6.1.4.1.6296.9.102.1.2.2.1.20 | ColumngfastPortStatusProfileName | read-only | current | Defines the Profile Name. |
| 1.3.6.1.4.1.6296.9.102.1.2.3 | TablegfastPortCounterTable | not-accessible | current | The G.fast port running counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1 | RowgfastPortCounterEntry | not-accessible | current | An entry in gfastPortCounterTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.1 | ColumngfastPortCounterUsMinEftr | read-only | current | Specifies the gfast Port's Up Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.2 | ColumngfastPortCounterDsMinEftr | read-only | current | Specifies the gfast Port's Down Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.3 | ColumngfastPortCounterUsFecs | read-only | current | Specifies the gfast Port's Up Stream Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.4 | ColumngfastPortCounterDsFecs | read-only | current | Specifies the gfast Port's Down Stream Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.5 | ColumngfastPortCounterUsLoss | read-only | current | Specifies the gfast Port's Up Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.6 | ColumngfastPortCounterDsLoss | read-only | current | Specifies the gfast Port's Down Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.7 | ColumngfastPortCounterUsEs | read-only | current | Specifies the gfast Port's Up Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.8 | ColumngfastPortCounterDsEs | read-only | current | Specifies the gfast Port's Down Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.9 | ColumngfastPortCounterUsSes | read-only | current | Specifies the gfast Port's Up Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.10 | ColumngfastPortCounterDsSes | read-only | current | Specifies the gfast Port's Down Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.11 | ColumngfastPortCounterUsUas | read-only | current | Specifies the gfast Port's Up Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.12 | ColumngfastPortCounterDsUas | read-only | current | Specifies the gfast Port's Down Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.13 | ColumngfastPortCounterUsCv | read-only | current | Specifies the gfast Port's Up Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.14 | ColumngfastPortCounterDsCv | read-only | current | Specifies the gfast Port's Down Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.15 | ColumngfastPortCounterUsLols | read-only | current | Specifies the gfast Port's Up Stream Loss of Link Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.16 | ColumngfastPortCounterDsLprs | read-only | current | Specifies the gfast Port's Down Stream Loss of Power Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.17 | ColumngfastPortCounterUncorrectedCw | read-only | current | Specifies the gfast Port's Up Stream Codeword that could not be correced. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.18 | ColumngfastPortCounterUsRtxCw | read-only | current | Specifies the gfast Port's Up Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.19 | ColumngfastPortCounterDsRtxCw | read-only | current | Specifies the gfast Port's Down Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.20 | ColumngfastPortCounterRtxCorrectedCw | read-only | current | Specifies the gfast Port's Up Stream Number of Codewords corrected through retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.21 | ColumngfastPortCounterRtxUncorrectedCw | read-only | current | Specifies the gfast Port's Up Stream Number of Codewords left uncorrected after retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.22 | ColumngfastPortCounterFullInitCount | read-only | current | Specifies the gfast Port's Full Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.3.1.23 | ColumngfastPortCounterFastInitCount | read-only | current | Specifies the gfast Port's Fast Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.4 | TablegfastPortCurrent15MCounterTable | not-accessible | current | The G.fast port Current 15min Counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1 | RowgfastPortCurrent15MCounterEntry | not-accessible | current | An entry in gfastPortCurrent15MCounterTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.1 | ColumngfastPortCurrent15MCounterUsMinEftr | read-only | current | Specifies the gfast Port's Current15Min Up Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.2 | ColumngfastPortCurrent15MCounterDsMinEftr | read-only | current | Specifies the gfast Port's Current15Min Down Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.3 | ColumngfastPortCurrent15MCounterUsFecs | read-only | current | Specifies the gfast Port's Current15Min Up Stream Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.4 | ColumngfastPortCurrent15MCounterDsFecs | read-only | current | Specifies the gfast Port's Current15Min Down Stream Current15Min Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.5 | ColumngfastPortCurrent15MCounterUsLoss | read-only | current | Specifies the gfast Port's Current15Min Up Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.6 | ColumngfastPortCurrent15MCounterDsLoss | read-only | current | Specifies the gfast Port's Current15Min Down Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.7 | ColumngfastPortCurrent15MCounterUsEs | read-only | current | Specifies the gfast Port's Current15Min Up Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.8 | ColumngfastPortCurrent15MCounterDsEs | read-only | current | Specifies the gfast Port's Current15Min Down Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.9 | ColumngfastPortCurrent15MCounterUsSes | read-only | current | Specifies the gfast Port's Current15Min Up Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.10 | ColumngfastPortCurrent15MCounterDsSes | read-only | current | Specifies the gfast Port's Current15Min Down Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.11 | ColumngfastPortCurrent15MCounterUsUas | read-only | current | Specifies the gfast Port's Current15Min Up Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.12 | ColumngfastPortCurrent15MCounterDsUas | read-only | current | Specifies the gfast Port's Current15Min Down Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.13 | ColumngfastPortCurrent15MCounterUsCv | read-only | current | Specifies the gfast Port's Current15Min Up Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.14 | ColumngfastPortCurrent15MCounterDsCv | read-only | current | Specifies the gfast Port's Current15Min Down Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.15 | ColumngfastPortCurrent15MCounterUsLols | read-only | current | Specifies the gfast Port's Current15Min Up Stream Loss of Link Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.16 | ColumngfastPortCurrent15MCounterDsLprs | read-only | current | Specifies the gfast Port's Current15Min Down Stream Loss of Power Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.17 | ColumngfastPortCurrent15MCounterUncorrectedCw | read-only | current | Specifies the gfast Port's Current15Min Up Stream Codeword that could not be correced. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.18 | ColumngfastPortCurrent15MCounterUsRtxCw | read-only | current | Specifies the gfast Port's Current15Min Up Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.19 | ColumngfastPortCurrent15MCounterDsRtxCw | read-only | current | Specifies the gfast Port's Current15Min Down Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.20 | ColumngfastPortCurrent15MCounterRtxCorrectedCw | read-only | current | Specifies the gfast Port's Current15Min Up Stream Number of Codewords corrected through retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.21 | ColumngfastPortCurrent15MCounterRtxUncorrectedCw | read-only | current | Specifies the gfast Port's Current15Min Up Stream Number of Codewords left uncorrected after retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.22 | ColumngfastPortCurrent15MCounterFullInitCount | read-only | current | Specifies the gfast Port's Current15Min Full Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.4.1.23 | ColumngfastPortCurrent15MCounterFastInitCount | read-only | current | Specifies the gfast Port's Current15Min Fast Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.5 | TablegfastPortPrevious15MCounterTable | not-accessible | current | The G.fast port Previos 15min Counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1 | RowgfastPortPrevious15MCounterEntry | not-accessible | current | An entry in gfastPortPrevious15MCounterTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.1 | ColumngfastPortPrevious15MCounterUsMinEftr | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.2 | ColumngfastPortPrevious15MCounterDsMinEftr | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.3 | ColumngfastPortPrevious15MCounterUsFecs | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.4 | ColumngfastPortPrevious15MCounterDsFecs | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Previous15Min Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.5 | ColumngfastPortPrevious15MCounterUsLoss | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.6 | ColumngfastPortPrevious15MCounterDsLoss | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.7 | ColumngfastPortPrevious15MCounterUsEs | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.8 | ColumngfastPortPrevious15MCounterDsEs | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.9 | ColumngfastPortPrevious15MCounterUsSes | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.10 | ColumngfastPortPrevious15MCounterDsSes | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.11 | ColumngfastPortPrevious15MCounterUsUas | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.12 | ColumngfastPortPrevious15MCounterDsUas | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.13 | ColumngfastPortPrevious15MCounterUsCv | read-only | current | Specifies the gfast Port's Previous15Min Up Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.14 | ColumngfastPortPrevious15MCounterDsCv | read-only | current | Specifies the gfast Port's Previous15Min Down Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.15 | ColumngfastPortPrevious15MCounterUsLols | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Loss of Link Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.16 | ColumngfastPortPrevious15MCounterDsLprs | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Loss of Power Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.17 | ColumngfastPortPrevious15MCounterUncorrectedCw | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Codeword that could not be correced. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.18 | ColumngfastPortPrevious15MCounterUsRtxCw | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.19 | ColumngfastPortPrevious15MCounterDsRtxCw | read-only | current | Specifies the gfast Port's Previous15Min Down Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.20 | ColumngfastPortPrevious15MCounterRtxCorrectedCw | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Number of Codewords corrected through retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.21 | ColumngfastPortPrevious15MCounterRtxUncorrectedCw | read-only | current | Specifies the gfast Port's Previous15Min Up Stream Number of Codewords left uncorrected after retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.22 | ColumngfastPortPrevious15MCounterFullInitCount | read-only | current | Specifies the gfast Port's Previous15Min Full Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.5.1.23 | ColumngfastPortPrevious15MCounterFastInitCount | read-only | current | Specifies the gfast Port's Previous15Min Fast Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.6 | TablegfastPortCurrent1DayCounterTable | not-accessible | current | The G.fast port Current 1day Counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1 | RowgfastPortCurrent1DayCounterEntry | not-accessible | current | An entry in gfastPortCurrent1DayCounterTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.1 | ColumngfastPortCurrent1DayCounterUsMinEftr | read-only | current | Specifies the gfast Port's Current1day Up Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.2 | ColumngfastPortCurrent1DayCounterDsMinEftr | read-only | current | Specifies the gfast Port's Current1day Down Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.3 | ColumngfastPortCurrent1DayCounterUsFecs | read-only | current | Specifies the gfast Port's Current1day Up Stream Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.4 | ColumngfastPortCurrent1DayCounterDsFecs | read-only | current | Specifies the gfast Port's Current1day Down Stream Current1day Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.5 | ColumngfastPortCurrent1DayCounterUsLoss | read-only | current | Specifies the gfast Port's Current1day Up Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.6 | ColumngfastPortCurrent1DayCounterDsLoss | read-only | current | Specifies the gfast Port's Current1day Down Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.7 | ColumngfastPortCurrent1DayCounterUsEs | read-only | current | Specifies the gfast Port's Current1day Up Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.8 | ColumngfastPortCurrent1DayCounterDsEs | read-only | current | Specifies the gfast Port's Current1day Down Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.9 | ColumngfastPortCurrent1DayCounterUsSes | read-only | current | Specifies the gfast Port's Current1day Up Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.10 | ColumngfastPortCurrent1DayCounterDsSes | read-only | current | Specifies the gfast Port's Current1day Down Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.11 | ColumngfastPortCurrent1DayCounterUsUas | read-only | current | Specifies the gfast Port's Current1day Up Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.12 | ColumngfastPortCurrent1DayCounterDsUas | read-only | current | Specifies the gfast Port's Current1day Down Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.13 | ColumngfastPortCurrent1DayCounterUsCv | read-only | current | Specifies the gfast Port's Current1day Up Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.14 | ColumngfastPortCurrent1DayCounterDsCv | read-only | current | Specifies the gfast Port's Current1day Down Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.15 | ColumngfastPortCurrent1DayCounterUsLols | read-only | current | Specifies the gfast Port's Current1day Up Stream Loss of Link Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.16 | ColumngfastPortCurrent1DayCounterDsLprs | read-only | current | Specifies the gfast Port's Current1day Down Stream Loss of Power Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.17 | ColumngfastPortCurrent1DayCounterUncorrectedCw | read-only | current | Specifies the gfast Port's Current1day Up Stream Codeword that could not be correced. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.18 | ColumngfastPortCurrent1DayCounterUsRtxCw | read-only | current | Specifies the gfast Port's Current1day Up Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.19 | ColumngfastPortCurrent1DayCounterDsRtxCw | read-only | current | Specifies the gfast Port's Current1day Down Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.20 | ColumngfastPortCurrent1DayCounterRtxCorrectedCw | read-only | current | Specifies the gfast Port's Current1day Up Stream Number of Codewords corrected through retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.21 | ColumngfastPortCurrent1DayCounterRtxUncorrectedCw | read-only | current | Specifies the gfast Port's Current1day Up Stream Number of Codewords left uncorrected after retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.22 | ColumngfastPortCurrent1DayCounterFullInitCount | read-only | current | Specifies the gfast Port's Current1day Full Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.6.1.23 | ColumngfastPortCurrent1DayCounterFastInitCount | read-only | current | Specifies the gfast Port's Current1day Fast Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.7 | TablegfastPortPrevious1DayCounterTable | not-accessible | current | The G.fast port Previous 1day Counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1 | RowgfastPortPrevious1DayCounterEntry | not-accessible | current | An entry in gfastPortPrevious1DayCounterTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.1 | ColumngfastPortPrevious1DayCounterUsMinEftr | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.2 | ColumngfastPortPrevious1DayCounterDsMinEftr | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Minimum Error Free Throughput. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.3 | ColumngfastPortPrevious1DayCounterUsFecs | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.4 | ColumngfastPortPrevious1DayCounterDsFecs | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Previous1Day Forward Error Collection Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.5 | ColumngfastPortPrevious1DayCounterUsLoss | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.6 | ColumngfastPortPrevious1DayCounterDsLoss | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Loss of signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.7 | ColumngfastPortPrevious1DayCounterUsEs | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.8 | ColumngfastPortPrevious1DayCounterDsEs | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.9 | ColumngfastPortPrevious1DayCounterUsSes | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.10 | ColumngfastPortPrevious1DayCounterDsSes | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.11 | ColumngfastPortPrevious1DayCounterUsUas | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.12 | ColumngfastPortPrevious1DayCounterDsUas | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.13 | ColumngfastPortPrevious1DayCounterUsCv | read-only | current | Specifies the gfast Port's Previous1Day Up Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.14 | ColumngfastPortPrevious1DayCounterDsCv | read-only | current | Specifies the gfast Port's Previous1Day Down Stream CRC Violations. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.15 | ColumngfastPortPrevious1DayCounterUsLols | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Loss of Link Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.16 | ColumngfastPortPrevious1DayCounterDsLprs | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Loss of Power Seconds. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.17 | ColumngfastPortPrevious1DayCounterUncorrectedCw | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Codeword that could not be correced. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.18 | ColumngfastPortPrevious1DayCounterUsRtxCw | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.19 | ColumngfastPortPrevious1DayCounterDsRtxCw | read-only | current | Specifies the gfast Port's Previous1Day Down Stream Number of Codewords retransmitted. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.20 | ColumngfastPortPrevious1DayCounterRtxCorrectedCw | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Number of Codewords corrected through retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.21 | ColumngfastPortPrevious1DayCounterRtxUncorrectedCw | read-only | current | Specifies the gfast Port's Previous1Day Up Stream Number of Codewords left uncorrected after retransmission. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.22 | ColumngfastPortPrevious1DayCounterFullInitCount | read-only | current | Specifies the gfast Port's Previous1Day Full Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.7.1.23 | ColumngfastPortPrevious1DayCounterFastInitCount | read-only | current | Specifies the gfast Port's Previous1Day Fast Init Count. |
| 1.3.6.1.4.1.6296.9.102.1.2.8 | TablegfastPortEventTable | not-accessible | current | The G.fast port running event counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1 | RowgfastPortEventEntry | not-accessible | current | An entry in gfastPortEventTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.1 | ColumngfastPortEventUsLos | read-only | current | Specifies the gfast Port's Up Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.2 | ColumngfastPortEventDsLos | read-only | current | Specifies the gfast Port's Down Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.3 | ColumngfastPortEventUsLom | read-only | current | Specifies the gfast Port's Up Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.4 | ColumngfastPortEventDsLom | read-only | current | Specifies the gfast Port's Down Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.5 | ColumngfastPortEventUsLor | read-only | current | Specifies the gfast Port's Up Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.6 | ColumngfastPortEventDsLor | read-only | current | Specifies the gfast Port's Down Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.7 | ColumngfastPortEventLpr | read-only | current | Specifies the gfast Port's Loss of Power. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.8 | ColumngfastPortEventLol | read-only | current | Specifies the gfast Port's LOL. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.9 | ColumngfastPortEventUsBs | read-only | current | Specifies the gfast Port's Up Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.10 | ColumngfastPortEventDsBs | read-only | current | Specifies the gfast Port's Down Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.11 | ColumngfastPortEventUsRau | read-only | current | Specifies the gfast Port's Up Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.12 | ColumngfastPortEventDsRau | read-only | current | Specifies the gfast Port's Down Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.13 | ColumngfastPortEventUsRad | read-only | current | Specifies the gfast Port's Up Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.14 | ColumngfastPortEventDsRad | read-only | current | Specifies the gfast Port's Down Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.15 | ColumngfastPortEventUsFra | read-only | current | Specifies the gfast Port's Up Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.16 | ColumngfastPortEventDsFra | read-only | current | Specifies the gfast Port's Down Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.17 | ColumngfastPortEventUsRpa | read-only | current | Specifies the gfast Port's Up Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.18 | ColumngfastPortEventDsRpa | read-only | current | Specifies the gfast Port's Down Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.8.1.19 | ColumngfastPortEventTiga | read-only | current | Specifies the gfast Port's Transmitter Initiated Gain Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.9 | TablegfastPortCurr15MinEventTable | not-accessible | current | The G.fast port Current 15Minutes Event counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1 | RowgfastPortCurr15MinEventEntry | not-accessible | current | An entry in gfastPortCurr15MinEventTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.1 | ColumngfastPortCurr15MinEventUsLos | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.2 | ColumngfastPortCurr15MinEventDsLos | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.3 | ColumngfastPortCurr15MinEventUsLom | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.4 | ColumngfastPortCurr15MinEventDsLom | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.5 | ColumngfastPortCurr15MinEventUsLor | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.6 | ColumngfastPortCurr15MinEventDsLor | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.7 | ColumngfastPortCurr15MinEventLpr | read-only | current | Specifies the gfast Port's Current 15Minutes Loss of Power. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.8 | ColumngfastPortCurr15MinEventLol | read-only | current | Specifies the gfast Port's Current 15Minutes LOL. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.9 | ColumngfastPortCurr15MinEventUsBs | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.10 | ColumngfastPortCurr15MinEventDsBs | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.11 | ColumngfastPortCurr15MinEventUsRau | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.12 | ColumngfastPortCurr15MinEventDsRau | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.13 | ColumngfastPortCurr15MinEventUsRad | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.14 | ColumngfastPortCurr15MinEventDsRad | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.15 | ColumngfastPortCurr15MinEventUsFra | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.16 | ColumngfastPortCurr15MinEventDsFra | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.17 | ColumngfastPortCurr15MinEventUsRpa | read-only | current | Specifies the gfast Port's Current 15Minutes Up Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.18 | ColumngfastPortCurr15MinEventDsRpa | read-only | current | Specifies the gfast Port's Current 15Minutes Down Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.9.1.19 | ColumngfastPortCurr15MinEventTiga | read-only | current | Specifies the gfast Port's Current 15Minutes Transmitter Initiated Gain Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.10 | TablegfastPortPrev15MinEventTable | not-accessible | current | The G.fast port previous 15Minutes event counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1 | RowgfastPortPrev15MinEventEntry | not-accessible | current | An entry in gfastPortPrev15MinEventTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.1 | ColumngfastPortPrev15MinEventUsLos | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.2 | ColumngfastPortPrev15MinEventDsLos | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.3 | ColumngfastPortPrev15MinEventUsLom | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.4 | ColumngfastPortPrev15MinEventDsLom | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.5 | ColumngfastPortPrev15MinEventUsLor | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.6 | ColumngfastPortPrev15MinEventDsLor | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.7 | ColumngfastPortPrev15MinEventLpr | read-only | current | Specifies the gfast Port's Previous 15Minutes Loss of Power. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.8 | ColumngfastPortPrev15MinEventLol | read-only | current | Specifies the gfast Port's Previous 15Minutes LOL. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.9 | ColumngfastPortPrev15MinEventUsBs | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.10 | ColumngfastPortPrev15MinEventDsBs | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.11 | ColumngfastPortPrev15MinEventUsRau | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.12 | ColumngfastPortPrev15MinEventDsRau | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.13 | ColumngfastPortPrev15MinEventUsRad | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.14 | ColumngfastPortPrev15MinEventDsRad | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.15 | ColumngfastPortPrev15MinEventUsFra | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.16 | ColumngfastPortPrev15MinEventDsFra | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.17 | ColumngfastPortPrev15MinEventUsRpa | read-only | current | Specifies the gfast Port's Previous 15Minutes Up Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.18 | ColumngfastPortPrev15MinEventDsRpa | read-only | current | Specifies the gfast Port's Previous 15Minutes Down Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.10.1.19 | ColumngfastPortPrev15MinEventTiga | read-only | current | Specifies the gfast Port's Previous 15Minutes Transmitter Initiated Gain Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.11 | TablegfastPortCurr1DayEventTable | not-accessible | current | The G.fast port Current 1Day event counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1 | RowgfastPortCurr1DayEventEntry | not-accessible | current | An entry in gfastPortCurr1DayEventTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.1 | ColumngfastPortCurr1DayEventUsLos | read-only | current | Specifies the gfast Port's Current 1Day Up Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.2 | ColumngfastPortCurr1DayEventDsLos | read-only | current | Specifies the gfast Port's Current 1Day Down Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.3 | ColumngfastPortCurr1DayEventUsLom | read-only | current | Specifies the gfast Port's Current 1Day Up Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.4 | ColumngfastPortCurr1DayEventDsLom | read-only | current | Specifies the gfast Port's Current 1Day Down Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.5 | ColumngfastPortCurr1DayEventUsLor | read-only | current | Specifies the gfast Port's Current 1Day Up Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.6 | ColumngfastPortCurr1DayEventDsLor | read-only | current | Specifies the gfast Port's Current 1Day Down Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.7 | ColumngfastPortCurr1DayEventLpr | read-only | current | Specifies the gfast Port's Current 1Day Loss of Power. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.8 | ColumngfastPortCurr1DayEventLol | read-only | current | Specifies the gfast Port's Current 1Day LOL. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.9 | ColumngfastPortCurr1DayEventUsBs | read-only | current | Specifies the gfast Port's Current 1Day Up Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.10 | ColumngfastPortCurr1DayEventDsBs | read-only | current | Specifies the gfast Port's Current 1Day Down Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.11 | ColumngfastPortCurr1DayEventUsRau | read-only | current | Specifies the gfast Port's Current 1Day Up Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.12 | ColumngfastPortCurr1DayEventDsRau | read-only | current | Specifies the gfast Port's Current 1Day Down Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.13 | ColumngfastPortCurr1DayEventUsRad | read-only | current | Specifies the gfast Port's Current 1Day Up Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.14 | ColumngfastPortCurr1DayEventDsRad | read-only | current | Specifies the gfast Port's Current 1Day Down Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.15 | ColumngfastPortCurr1DayEventUsFra | read-only | current | Specifies the gfast Port's Current 1Day Up Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.16 | ColumngfastPortCurr1DayEventDsFra | read-only | current | Specifies the gfast Port's Current 1Day Down Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.17 | ColumngfastPortCurr1DayEventUsRpa | read-only | current | Specifies the gfast Port's Current 1Day Up Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.18 | ColumngfastPortCurr1DayEventDsRpa | read-only | current | Specifies the gfast Port's Current 1Day Down Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.11.1.19 | ColumngfastPortCurr1DayEventTiga | read-only | current | Specifies the gfast Port's Current 1Day Transmitter Initiated Gain Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.12 | TablegfastPortPrev1DayEventTable | not-accessible | current | The G.fast port Previous 1Day event counter table |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1 | RowgfastPortPrev1DayEventEntry | not-accessible | current | An entry in gfastPortPrev1DayEventTable. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.1 | ColumngfastPortPrev1DayEventUsLos | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.2 | ColumngfastPortPrev1DayEventDsLos | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream Loss Of Signal. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.3 | ColumngfastPortPrev1DayEventUsLom | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.4 | ColumngfastPortPrev1DayEventDsLom | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream Loss Of Margin. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.5 | ColumngfastPortPrev1DayEventUsLor | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.6 | ColumngfastPortPrev1DayEventDsLor | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream Loss of RMC. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.7 | ColumngfastPortPrev1DayEventLpr | read-only | current | Specifies the gfast Port's Previous 1Day Loss of Power. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.8 | ColumngfastPortPrev1DayEventLol | read-only | current | Specifies the gfast Port's Previous 1Day LOL. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.9 | ColumngfastPortPrev1DayEventUsBs | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.10 | ColumngfastPortPrev1DayEventDsBs | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream Bit-Swap. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.11 | ColumngfastPortPrev1DayEventUsRau | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.12 | ColumngfastPortPrev1DayEventDsRau | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream Rate Adaptation Upwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.13 | ColumngfastPortPrev1DayEventUsRad | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.14 | ColumngfastPortPrev1DayEventDsRad | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream Rate Adaptation Downwards. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.15 | ColumngfastPortPrev1DayEventUsFra | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.16 | ColumngfastPortPrev1DayEventDsFra | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream FRA. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.17 | ColumngfastPortPrev1DayEventUsRpa | read-only | current | Specifies the gfast Port's Previous 1Day Up Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.18 | ColumngfastPortPrev1DayEventDsRpa | read-only | current | Specifies the gfast Port's Previous 1Day Down Stream RMC Parameter Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.12.1.19 | ColumngfastPortPrev1DayEventTiga | read-only | current | Specifies the gfast Port's Previous 1Day Transmitter Initiated Gain Adjustment. |
| 1.3.6.1.4.1.6296.9.102.1.2.13 | TablegfastPortCounterClearTable | not-accessible | current | This table includes G.fast Port's Counter Clear Table. |
| 1.3.6.1.4.1.6296.9.102.1.2.13.1 | RowgfastPortCounterClearEntry | not-accessible | current | An entry in the G.fast Port's Counter Clear Table. |
| 1.3.6.1.4.1.6296.9.102.1.2.13.1.1 | ColumngfastPortCounterClearCommand | read-write | current | Clear G.FAST Port's Counter. |
| 1.3.6.1.4.1.6296.9.102.1.3 | NodegfastPortSubcarrierGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.3.1 | NodegfastBitAllocPerScGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.3.1.1 | ScalargfastBitAllocPortNumber | read-write | current | Specifies the gFastMIB System Port index. |
| 1.3.6.1.4.1.6296.9.102.1.3.1.2 | ScalargfastBitAllocGetCommand | read-write | current | Specifies the Bit Alloc per sub carrier request command |
| 1.3.6.1.4.1.6296.9.102.1.3.1.3 | TablegfastBitAllocTable | not-accessible | current | This table includes G.fast Bit Allocation Per Sub-carrier Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.1.3.1 | RowgfastBitAllocEntry | not-accessible | current | An entry in the gfast BitAllocation Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.1.3.1.1 | ColumngfastBitAllocToneIndex | read-only | current | Specifies the G.Fast bit allocation Tone Index. |
| 1.3.6.1.4.1.6296.9.102.1.3.1.3.1.2 | ColumngfastBitAlloc | read-only | current | Specifies the G.Fast US/DS bit allocation value. |
| 1.3.6.1.4.1.6296.9.102.1.3.2 | NodegfastSnrPerScGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.3.2.1 | ScalargfastSnrPortNumber | read-write | current | Specifies the gFastMIB System Port index. |
| 1.3.6.1.4.1.6296.9.102.1.3.2.2 | ScalargfastSnrGetCommand | read-write | current | Specifies the SNR per sub carrier request command |
| 1.3.6.1.4.1.6296.9.102.1.3.2.3 | TablegfastSnrTable | not-accessible | current | This table includes G.fast Snr Per Sub-carrier Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.2.3.1 | RowgfastSnrEntry | not-accessible | current | An entry in the gfast SNR Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.2.3.1.1 | ColumngfastSnrToneIndex | read-only | current | Specifies the G.Fast SNR Tone Index. |
| 1.3.6.1.4.1.6296.9.102.1.3.2.3.1.2 | ColumngfastSnr | read-only | current | Specifies the G.Fast US/DS SNR value. |
| 1.3.6.1.4.1.6296.9.102.1.3.3 | NodegfastHlogPerSgGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.3.3.1 | ScalargfastHlogPortNumber | read-write | current | Specifies the gFastMIB System Port index. |
| 1.3.6.1.4.1.6296.9.102.1.3.3.2 | ScalargfastHlogGetCommand | read-write | current | Specifies the HLOG per sub carrier request command |
| 1.3.6.1.4.1.6296.9.102.1.3.3.3 | TablegfastHlogTable | not-accessible | current | This table includes G.fast HLOG Per Sub-carrier group Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.3.3.1 | RowgfastHlogEntry | not-accessible | current | An entry in the gfast HLOG Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.3.3.1.1 | ColumngfastHlogToneIndex | read-only | current | Specifies the G.Fast HLOG Tone Index. |
| 1.3.6.1.4.1.6296.9.102.1.3.3.3.1.2 | ColumngfastHlog | read-only | current | Specifies the G.Fast US/DS HLOG value. |
| 1.3.6.1.4.1.6296.9.102.1.3.4 | NodegfastQlnPerSgGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.3.4.1 | ScalargfastQlnPortNumber | read-write | current | Specifies the gFastMIB System Port index. |
| 1.3.6.1.4.1.6296.9.102.1.3.4.2 | ScalargfastQlnGetCommand | read-write | current | Specifies the Qln per sub carrier request command |
| 1.3.6.1.4.1.6296.9.102.1.3.4.3 | TablegfastQlnTable | not-accessible | current | This table includes G.fast QLN Per Sub-carrier group Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.4.3.1 | RowgfastQlnEntry | not-accessible | current | An entry in the gfast Qln Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.4.3.1.1 | ColumngfastQlnToneIndex | read-only | current | Specifies the G.Fast Qln Tone Index. |
| 1.3.6.1.4.1.6296.9.102.1.3.4.3.1.2 | ColumngfastQln | read-only | current | Specifies the G.Fast US/DS Qln value. |
| 1.3.6.1.4.1.6296.9.102.1.3.5 | NodegfastAlnPerSgGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.3.5.1 | ScalargfastAlnPortNumber | read-write | current | Specifies the gFastMIB System Port index. |
| 1.3.6.1.4.1.6296.9.102.1.3.5.2 | ScalargfastAlnGetCommand | read-write | current | Specifies the Aln per sub carrier request command |
| 1.3.6.1.4.1.6296.9.102.1.3.5.3 | TablegfastAlnTable | not-accessible | current | This table includes G.fast ALN Per Sub-carrier group Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.5.3.1 | RowgfastAlnEntry | not-accessible | current | An entry in the gfast Aln Table. |
| 1.3.6.1.4.1.6296.9.102.1.3.5.3.1.1 | ColumngfastAlnToneIndex | read-only | current | Specifies the G.Fast Aln Tone Index. |
| 1.3.6.1.4.1.6296.9.102.1.3.5.3.1.2 | ColumngfastAln | read-only | current | Specifies the G.Fast DS Aln value. |
| 1.3.6.1.4.1.6296.9.102.1.4 | NodegfastProfileGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.4.1 | ScalargfastProfileCreate | read-write | current | Create a Gfast profile. Input Profile name. |
| 1.3.6.1.4.1.6296.9.102.1.4.2 | ScalargfastProfileDelete | read-write | current | Delete a Gfast profile. Input Profile name. |
| 1.3.6.1.4.1.6296.9.102.1.4.5 | TablegfastProfileTable | not-accessible | current | This table includes Gfast Profile Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1 | RowgfastProfileEntry | not-accessible | current | An entry in the gfastProfileTable. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.1 | ColumngfastProfileIndex | read-only | current | Specifies the Gfast System's Profile index. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.2 | ColumngfastProfileName | read-only | current | Defines the Profile Name. It ranges from 1 to 16 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.3 | ColumngfastProfileAddPort | read-write | current | To apply a profile to a port. Enter the port number. ex) 1 | 1,4 | 1-4 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.4 | ColumngfastProfileDelPort | read-write | current | Remove the port profile is applied. Enter the port number. ex) 1 | 1,4 | 1-4 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.5 | ColumngfastProfileActive | read-write | current | Activate the profile. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.6 | ColumngfastProfileUsBandPlanLower | read-write | current | Specifies the gfast Port's Up stream Lower Band plan. It range from 43 to 2042 units is 1 sub-carrier (frequency = sub-carier * 51.75kHz) |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.7 | ColumngfastProfileUsBandPlanUpper | read-write | current | Specifies the gfast Port's Up stream Upper Band plan. It range from 43 to 2042 units is 1 sub-carrier (frequency = sub-carier * 51.75kHz) |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.8 | ColumngfastProfileDsBandPlanLower | read-write | current | Specifies the gfast Port's Down stream Lower Band plan. It range from 43 to 2042 units is 1 sub-carrier (frequency = sub-carier * 51.75kHz) |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.9 | ColumngfastProfileDsBandPlanUpper | read-write | current | Specifies the gfast Port's Down stream Upper Band plan. It range from 43 to 2042 units is 1 sub-carrier (frequency = sub-carier * 51.75kHz) |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.10 | ColumngfastProfileUsMaxNDR | read-write | current | Specifies the gfast Port's Up stream Maximum Data Rate. It range from 15000 to 1000000 units is 1 kbps |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.11 | ColumngfastProfileDsMaxNDR | read-write | current | Specifies the gfast Port's Down stream Maximum Data Rate. It range from 15000 to 1000000 units is 1 kbps |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.12 | ColumngfastProfileUsTargetMargin | read-write | current | Specifies the gfast Port's Up stream Target noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.13 | ColumngfastProfileDsTargetMargin | read-write | current | Specifies the gfast Port's Down stream Target noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.14 | ColumngfastProfileUsMaxMargin | read-write | current | Specifies the gfast Port's Up stream Max noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.15 | ColumngfastProfileDsMaxMargin | read-write | current | Specifies the gfast Port's Down stream Max noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.16 | ColumngfastProfileUsMinMargin | read-write | current | Specifies the gfast Port's Up stream Min noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.17 | ColumngfastProfileDsMinMargin | read-write | current | Specifies the gfast Port's Down stream Min noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.18 | ColumngfastProfileUsMaxTxPower | read-write | current | Specifies the gfast Port's Up stream Maximum allowed transmit power. It range from -130 to 200 units is 0.1 dBm |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.19 | ColumngfastProfileDsMaxTxPower | read-write | current | Specifies the gfast Port's Down stream Maximum allowed transmit power. It range from -50 to 200 units is 0.1 dBm |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.20 | ColumngfastProfileUsSraMode | read-write | current | Specifies the gfast Port's Up stream Rate Adaption admin. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.21 | ColumngfastProfileDsSraMode | read-write | current | Specifies the gfast Port's Down stream Rate Adaption admin. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.22 | ColumngfastProfileUsUpShiftMargin | read-write | current | Specifies the gfast Port's Up stream up-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.23 | ColumngfastProfileUsDownShiftMargin | read-write | current | Specifies the gfast Port's Up stream down-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.24 | ColumngfastProfileDsUpShiftMargin | read-write | current | Specifies the gfast Port's Down stream up-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.25 | ColumngfastProfileDsDownShiftMargin | read-write | current | Specifies the gfast Port's Down stream down-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.26 | ColumngfastProfileUsUpShiftInterval | read-write | current | Specifies the gfast Port's Up stream up-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.27 | ColumngfastProfileUsDownShiftInterval | read-write | current | Specifies the gfast Port's Up stream down-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.28 | ColumngfastProfileDsUpShiftInterval | read-write | current | Specifies the gfast Port's Down stream up-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.29 | ColumngfastProfileDsDownShiftInterval | read-write | current | Specifies the gfast Port's Down stream down-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.30 | ColumngfastProfileUsRpaMode | read-write | current | Specifies the gfast Port's Up stream RMC parameter adjustment admin. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.31 | ColumngfastProfileDsRpaMode | read-write | current | Specifies the gfast Port's Down stream RMC parameter adjustment admin. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.32 | ColumngfastProfileUsTargetMarginRmc | read-write | current | Specifies the gfast Port's Up stream target SNR margin of the RMC. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.33 | ColumngfastProfileDsTargetMarginRmc | read-write | current | Specifies the gfast Port's Down stream target SNR margin of the RMC. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.34 | ColumngfastProfileUsMinMarginRmc | read-write | current | Specifies the gfast Port's Up stream minimum SNR margin of the RMC. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.35 | ColumngfastProfileDsMinMarginRmc | read-write | current | Specifies the gfast Port's Down stream minimum SNR margin of the RMC. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.36 | ColumngfastProfileUsMaxBitloadingRmc | read-write | current | Specifies the gfast Port's Up stream maximum bit loading allowed for RMC sub-carrier. It range from 2 to 6 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.37 | ColumngfastProfileDsMaxBitloadingRmc | read-write | current | Specifies the gfast Port's Down stream maximum bit loading allowed for RMC sub-carrier. It range from 2 to 6 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.38 | ColumngfastProfileUsFraMode | read-write | current | Specifies the gfast Port's Up stream Fast Rate Adaptation admin. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.39 | ColumngfastProfileDsFraMode | read-write | current | Specifies the gfast Port's Down stream Fast Rate Adaptation admin. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.40 | ColumngfastProfileUsFraTime | read-write | current | Specifies the gfast Port's Up stream duration of the FRA time window used in the standard FRA triggering criteria. It range from 0 to 8 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.41 | ColumngfastProfileDsFraTime | read-write | current | Specifies the gfast Port's Down stream duration of the FRA time window used in the standard FRA triggering criteria. It range from 0 to 8 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.42 | ColumngfastProfileUsFraNtones | read-write | current | Specifies the gfast Port's Up stream minimum percentage of degraded loaded sub-carriers during FRA-TIME in order to arm the first FRA triggering criteria. It r… |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.43 | ColumngfastProfileDsFraNtones | read-write | current | Specifies the gfast Port's Down stream minimum percentage of degraded loaded sub-carriers during FRA-TIME in order to arm the first FRA triggering criteria. It… |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.44 | ColumngfastProfileUsFraRtxUc | read-write | current | Specifies the gfast Port's Up stream minimum number of rtx-uc anomalies received during FRA-TIME in order to arm the second FRA triggering criteria. It range f… |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.45 | ColumngfastProfileDsFraRtxUc | read-write | current | Specifies the gfast Port's Down stream minimum number of rtx-uc anomalies received during FRA-TIME in order to arm the second FRA triggering criteria. It range… |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.46 | ColumngfastProfileUsFraVendisc | read-write | current | Specifies the gfast Port's Up stream whether vendor discretionary FRA triggering criteria may be used. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.47 | ColumngfastProfileDsFraVendisc | read-write | current | Specifies the gfast Port's Down stream whether vendor discretionary FRA triggering criteria may be used. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.48 | ColumngfastProfileRtxUsETRmin | read-write | current | Specifies the gfast Port's Up stream minimum Expected Throughput Rate. It range from 0 to Max-NDR units is 1kbps. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.49 | ColumngfastProfileRtxDsETRmin | read-write | current | Specifies the gfast Port's Down stream minimum Expected Throughput Rate. It range from 0 to Max-NDR units is 1kbps |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.50 | ColumngfastProfileRtxUsMaxDelay | read-write | current | Specifies the gfast Port's Up stream maximum allowed delay for retransmission. It range from 0 to 63000 units is 1 micro sec |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.51 | ColumngfastProfileRtxDsMaxDelay | read-write | current | Specifies the gfast Port's Down stream maximum allowed delay for retransmission. It range from 0 to 63000 units is 1 micro sec |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.52 | ColumngfastProfileRtxUsInpMinShine | read-write | current | Specifies the gfast Port's Up stream minimum impulse noise protection against SHINE. It range from 0 to 1040 units is 0.5symbol |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.53 | ColumngfastProfileRtxDsInpMinShine | read-write | current | Specifies the gfast Port's Down stream minimum impulse noise protection against SHINE. It range from 0 to 1040 units is 0.5symbol |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.54 | ColumngfastProfileRtxUsShineRatio | read-write | current | Specifies the gfast Port's Up stream SHINE ratio. It range from 0 to 100 units is 0.001 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.55 | ColumngfastProfileRtxDsShineRatio | read-write | current | Specifies the gfast Port's Down stream SHINE ratio. It range from 0 to 100 units is 0.001 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.56 | ColumngfastProfileRtxUsInpMinRein | read-write | current | Specifies the gfast Port's Up stream minimum impulse noise protection against REIN. It range from 0 to 126 units is 0.5symbol |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.57 | ColumngfastProfileRtxDsInpMinRein | read-write | current | Specifies the gfast Port's Down stream minimum impulse noise protection against REIN. It range from 0 to 126 units is 0.5symbol |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.58 | ColumngfastProfileRtxUsIatReinFlag | read-write | current | Specifies the gfast Port's Up stream inter arrival time of REIN. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.59 | ColumngfastProfileRtxDsIatReinFlag | read-write | current | Specifies the gfast Port's Down stream inter arrival time of REIN. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.60 | ColumngfastProfileRtxUsRNratio | read-write | current | Specifies the gfast Port's Up stream minimum ratio R/N. It range from 0 to 8 unit is 1/32 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.61 | ColumngfastProfileRtxDsRNratio | read-write | current | Specifies the gfast Port's Down stream minimum ratio R/N. It range from 0 to 8 unit is 1/32 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.62 | ColumngfastProfileUpboAdmin | read-create | current | The identifier for G.FAST UPBO |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.63 | ColumngfastProfileUpboAValue | read-create | current | Specifies the gfast Port's UPBO a value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.64 | ColumngfastProfileUpboBValue | read-create | current | Specifies the gfast Port's UPBO b value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.65 | ColumngfastProfileUpboKl0 | read-create | current | Specifies the gfast Port's UPBO Electrical length estimation. value is 0 or 18 ~ 635. Unit is 0.1db |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.66 | ColumngfastProfileUsLosPersistency | read-write | current | Specifies the gfast Port's Up stream LOS Persistency. It range from 1 to 20. unit is 100ms. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.67 | ColumngfastProfileDsLosPersistency | read-write | current | Specifies the gfast Port's Down stream LOS Persistency. It range from 1 to 20. unit is 100ms. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.68 | ColumngfastProfileUsLorPersistency | read-write | current | Specifies the gfast Port's Up stream LOR Persistency. It range from 1 to 20. unit is 100ms. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.69 | ColumngfastProfileDsLorPersistency | read-write | current | Specifies the gfast Port's Down stream LOR Persistency. It range from 1 to 20. unit is 100ms. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.70 | ColumngfastProfileMaxBitloading | read-write | current | Specifies the gfast Port's Max Bitloading per tone. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.71 | ColumngfastProfileUsLomPersistency | read-write | current | Specifies the gfast Port's Up stream LOM Persistency. It range from 1 to 20. unit is 1sec. |
| 1.3.6.1.4.1.6296.9.102.1.4.5.1.72 | ColumngfastProfileDsLomPersistency | read-write | current | Specifies the gfast Port's Down stream LOM Persistency. It range from 1 to 20. unit is 1sec. |
| 1.3.6.1.4.1.6296.9.102.1.4.6 | TablegfastProfileUsPsdMaskTable | not-accessible | current | This table includes Gfast Profile Upstream PSD Mask Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.4.6.1 | RowgfastProfileUsPsdMaskEntry | not-accessible | current | An entry in the gfastProfileUsPsdMaskTable. |
| 1.3.6.1.4.1.6296.9.102.1.4.6.1.1 | ColumngfastProfileUsPsdMaskIndex | not-accessible | current | The identifier for G.FAST PSD Mask |
| 1.3.6.1.4.1.6296.9.102.1.4.6.1.2 | ColumngfastProfileUsPsdMaskTone | read-create | current | Specifies the gfast Port's Up stream PSD mask Sub-carrier index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz) |
| 1.3.6.1.4.1.6296.9.102.1.4.6.1.3 | ColumngfastProfileUsPsdMaskPSD | read-create | current | Specifies the gfast Port's Up stream PSD mask value. Unit is -0.1dB |
| 1.3.6.1.4.1.6296.9.102.1.4.6.1.4 | ColumngfastProfileUsPsdMaskRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.4.7 | TablegfastProfileDsPsdMaskTable | not-accessible | current | This table includes Gfast Profile Downstream PSD Mask Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.4.7.1 | RowgfastProfileDsPsdMaskEntry | not-accessible | current | An entry in the gfastProfileDsPsdMaskTable. |
| 1.3.6.1.4.1.6296.9.102.1.4.7.1.1 | ColumngfastProfileDsPsdMaskIndex | not-accessible | current | The identifier for G.FAST PSD Mask |
| 1.3.6.1.4.1.6296.9.102.1.4.7.1.2 | ColumngfastProfileDsPsdMaskTone | read-create | current | Specifies the gfast Port's Down stream PSD mask Sub-carrier index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.7.1.3 | ColumngfastProfileDsPsdMaskPSD | read-create | current | Specifies the gfast Port's Down stream PSD mask value. Unit is -0.1dB |
| 1.3.6.1.4.1.6296.9.102.1.4.7.1.4 | ColumngfastProfileDsPsdMaskRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.4.8 | TablegfastProfileUsCarrierMaskTable | not-accessible | current | This table includes Gfast Profile Upstream Carrier Mask Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.4.8.1 | RowgfastProfileUsCarrierMaskEntry | not-accessible | current | An entry in the gfastProfileUsCarrierMaskTable. |
| 1.3.6.1.4.1.6296.9.102.1.4.8.1.1 | ColumngfastProfileUsCarrierMaskIndex | not-accessible | current | The identifier for G.FAST Carrier Mask |
| 1.3.6.1.4.1.6296.9.102.1.4.8.1.2 | ColumngfastProfileUsCarrierMaskStartTone | read-create | current | Specifies the gfast Port's Up stream Carrier mask Sub-carrier start index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.8.1.3 | ColumngfastProfileUsCarrierMaskEndTone | read-create | current | Specifies the gfast Port's Up stream Carrier mask Sub-carrier end index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.8.1.4 | ColumngfastProfileUsCarrierMaskRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.4.9 | TablegfastProfileDsCarrierMaskTable | not-accessible | current | This table includes Gfast Profile Downstream Carrier Mask Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.4.9.1 | RowgfastProfileDsCarrierMaskEntry | not-accessible | current | An entry in the gfastProfileDsCarrierMaskTable. |
| 1.3.6.1.4.1.6296.9.102.1.4.9.1.1 | ColumngfastProfileDsCarrierMaskIndex | not-accessible | current | The identifier for G.FAST Carrier Mask |
| 1.3.6.1.4.1.6296.9.102.1.4.9.1.2 | ColumngfastProfileDsCarrierMaskStartTone | read-create | current | Specifies the gfast Port's Down stream Carrier mask Sub-carrier start index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.9.1.3 | ColumngfastProfileDsCarrierMaskEndTone | read-create | current | Specifies the gfast Port's Down stream Carrier mask Sub-carrier end index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.9.1.4 | ColumngfastProfileDsCarrierMaskRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.4.10 | TablegfastProfileRfiNotchTable | not-accessible | current | This table includes Gfast Profile RFI notching Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.4.10.1 | RowgfastProfileRfiNotchEntry | not-accessible | current | An entry in the gfastProfileRfiNotchTable. |
| 1.3.6.1.4.1.6296.9.102.1.4.10.1.1 | ColumngfastProfileRfiNotchIndex | not-accessible | current | The identifier for G.FAST RFI notching |
| 1.3.6.1.4.1.6296.9.102.1.4.10.1.2 | ColumngfastProfileRfiNotchStartTone | read-create | current | Specifies the gfast Port's Notching Sub-carrier start index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.10.1.3 | ColumngfastProfileRfiNotchEndTone | read-create | current | Specifies the gfast Port's Notching Sub-carrier end index. Unit is 1 sub-carrier (frequency = sub-carier * 51.75kHz |
| 1.3.6.1.4.1.6296.9.102.1.4.10.1.4 | ColumngfastProfileRfiNotchRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.5 | NodevdslProfileGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.5.1 | TablevdslProfileTable | not-accessible | current | This table includes Vdsl Profile Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1 | RowvdslProfileEntry | not-accessible | current | An entry in the vdslProfileTable. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.1 | ColumnvdslProfileIndex | read-only | current | Specifies the VDSL System's Profile index. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.2 | ColumnvdslProfileName | read-only | current | Defines the Profile Name. It ranges from 1 to 16 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.3 | ColumnvdslProfileShape | read-write | current | Specifies the vdsl profile shape. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.4 | ColumnvdslProfileBitmap8a | read-write | current | Specifies the VDSL profile 8a protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.5 | ColumnvdslProfileBitmap8b | read-write | current | Specifies the VDSL profile 8b protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.6 | ColumnvdslProfileBitmap8c | read-write | current | Specifies the VDSL profile 8c protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.7 | ColumnvdslProfileBitmap8d | read-write | current | Specifies the VDSL profile 8d protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.8 | ColumnvdslProfileBitmap12a | read-write | current | Specifies the VDSL profile 12a protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.9 | ColumnvdslProfileBitmap12b | read-write | current | Specifies the VDSL profile 12b protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.10 | ColumnvdslProfileBitmap17a | read-write | current | Specifies the VDSL profile 17a protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.11 | ColumnvdslProfileBitmap30a | read-write | current | Specifies the VDSL profile 30a protocol. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.12 | ColumnvdslProfileMaxTxPower | read-write | current | Specifies the vdsl maximum downstream transmit power. It range from -256 to 40 units is 0.1dBm. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.13 | ColumnvdslProfileMaxRxPower | read-write | current | Specifies the vdsl maximum upstream receive power. It range from -256 to 256 units is 0.1dBm. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.14 | ColumnvdslProfileUsTargetMargin | read-write | current | Specifies the vdsl Port's Up stream Target noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.15 | ColumnvdslProfileDsTargetMargin | read-write | current | Specifies the vdsl Port's Down stream Target noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.16 | ColumnvdslProfileUsMaxMargin | read-write | current | Specifies the vdsl Port's Up stream Max noise margin. It range from -1 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.17 | ColumnvdslProfileDsMaxMargin | read-write | current | Specifies the vdsl Port's Down stream Max noise margin. It range from -1 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.18 | ColumnvdslProfileUsMinMargin | read-write | current | Specifies the vdsl Port's Up stream Min noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.19 | ColumnvdslProfileDsMinMargin | read-write | current | Specifies the vdsl Port's Down stream Min noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.20 | ColumnvdslProfileUsSraMode | read-write | current | Specifies to enable vdsl Seamless Rate Adaptation(SRA) in the upstream. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.21 | ColumnvdslProfileDsSraMode | read-write | current | Specifies to enable vdsl Seamless Rate Adaptation(SRA) in the downstream. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.22 | ColumnvdslProfileUsUpShiftMargin | read-write | current | Specifies the vdsl Port's Up stream up-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.23 | ColumnvdslProfileUsDownShiftMargin | read-write | current | Specifies the vdsl Port's Up stream down-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.24 | ColumnvdslProfileDsUpShiftMargin | read-write | current | Specifies the vdsl Port's Down stream up-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.25 | ColumnvdslProfileDsDownShiftMargin | read-write | current | Specifies the vdsl Port's Down stream down-shift noise margin. It range from 0 to 310 units is 0.1 dB |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.26 | ColumnvdslProfileUsUpShiftInterval | read-write | current | Specifies the vdsl Port's Up stream up-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.27 | ColumnvdslProfileUsDownShiftInterval | read-write | current | Specifies the vdsl Port's Up stream down-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.28 | ColumnvdslProfileDsUpShiftInterval | read-write | current | Specifies the vdsl Port's Down stream up-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.29 | ColumnvdslProfileDsDownShiftInterval | read-write | current | Specifies the vdsl Port's Down stream down-shift time interval. It range from 0 to 16383 units is 1sec |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.30 | ColumnvdslProfileUsRtxEtrMin | read-write | current | Specifies the vdsl Port's upstream minimum value of the ETR. It range from 64 to 512000 units is 1Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.31 | ColumnvdslProfileDsRtxEtrMin | read-write | current | Specifies the vdsl Port's downstream minimum value of the ETR. It range from 64 to 512000 units is 1Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.32 | ColumnvdslProfileUsRtxEtrMax | read-write | current | Specifies the vdsl Port's upstream maximum value of the ETR. It range from 64 to 512000 units is 1Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.33 | ColumnvdslProfileDsRtxEtrMax | read-write | current | Specifies the vdsl Port's downstream maximum value of the ETR. It range from 64 to 512000 units is 1Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.34 | ColumnvdslProfileUsRtxMaxNdr | read-write | current | Specifies the vdsl Port's upstream maximum data rate. It range from 64 to 512000 units is 1Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.35 | ColumnvdslProfileDsRtxMaxNdr | read-write | current | Specifies the vdsl Port's downstream maximum data rate. It range from 64 to 512000 units is 1Kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.36 | ColumnvdslProfileUsRtxMaxDelay | read-write | current | Specifies the vdsl Port's upstream maximum delay. It range from 0 to 64 units is 1msec. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.37 | ColumnvdslProfileDsRtxMaxDelay | read-write | current | Specifies the vdsl Port's downstream maximum delay. It range from 0 to 64 units is 1msec. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.38 | ColumnvdslProfileUsRtxMinDelay | read-write | current | Specifies the vdsl Port's upstream minimum delay. It range from 0 to 64 units is 1msec. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.39 | ColumnvdslProfileDsRtxMinDelay | read-write | current | Specifies the vdsl Port's downstream minimum delay. It range from 0 to 64 units is 1msec. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.40 | ColumnvdslProfileUsRtxInpMinShine | read-write | current | Specifies the vdsl Port's Up stream minimum impulse noise protection against SHINE. It range from 0 to 126 units is a half DMT symbol |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.41 | ColumnvdslProfileDsRtxInpMinShine | read-write | current | Specifies the vdsl Port's Down stream minimum impulse noise protection against SHINE. It range from 0 to 126 units is a half DMT symbol |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.42 | ColumnvdslProfileUsRtxShineRatio | read-write | current | Specifies the vdsl Port's Up stream SHINE ratio. It range from 0 to 255 units is 0.001 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.43 | ColumnvdslProfileDsRtxShineRatio | read-write | current | Specifies the vdsl Port's Down stream SHINE ratio. It range from 0 to 255 units is 0.001 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.44 | ColumnvdslProfileUsRtxInpMinRein | read-write | current | Specifies the vdsl Port's Up stream minimum impulse noise protection against REIN. It range from 0 to 7 units is 1/2 symbol at 4kHz. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.45 | ColumnvdslProfileDsRtxInpMinRein | read-write | current | Specifies the vdsl Port's Down stream minimum impulse noise protection against REIN. It range from 0 to 7 units is 1/2 symbol at 4kHz. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.46 | ColumnvdslProfileUsRtxReinFrequency | read-write | current | Specifies the vdsl Port's Up stream rein frequency. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.47 | ColumnvdslProfileDsRtxReinFrequency | read-write | current | Specifies the vdsl Port's Down stream rein frequency. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.48 | ColumnvdslProfileUsRtxIatRnRatio | read-write | current | Specifies the vdsl Port's Up stream minimum ratio R/N. It range from 0 to 64 unit is 1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.49 | ColumnvdslProfileDsRtxIatRnRatio | read-write | current | Specifies the vdsl Port's Down stream minimum ratio R/N. It range from 0 to 64 unit is 1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.50 | ColumnvdslProfileUsSosMode | read-write | current | Specifies to enable vdsl port's upstream SOS mode. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.51 | ColumnvdslProfileDsSosMode | read-write | current | Specifies to enable vdsl port's downstream SOS mode. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.52 | ColumnvdslProfileUsSosMinRate | read-write | current | Specifies the vdsl Port's upstream minimum bearer rate. It range from 0 to 100000 units is 1kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.53 | ColumnvdslProfileDsSosMinRate | read-write | current | Specifies the vdsl Port's downstream minimum bearer rate. It range from 0 to 100000 units is 1kbps. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.54 | ColumnvdslProfileUsSosTime | read-write | current | Specifies the vdsl Port's Up stream SOS monitering time window. It range from 64 to 16320 units is 1ms. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.55 | ColumnvdslProfileDsSosTime | read-write | current | Specifies the vdsl Port's Down stream SOS monitering time window. It range from 64 to 16320 units is 1ms. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.56 | ColumnvdslProfileUsSosCrc | read-write | current | Specifies the vdsl Port's Up stream SOS CRC trigger condition. It range from 0 to 65535 units is 0.02. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.57 | ColumnvdslProfileDsSosCrc | read-write | current | Specifies the vdsl Port's Down stream SOS CRC trigger condition. It range from 0 to 65535 units is 0.02. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.58 | ColumnvdslProfileUsSosNtone | read-write | current | Specifies the vdsl Port's Up stream SOS tone degraded condition. It range from 0 to 100 units is percent. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.59 | ColumnvdslProfileDsSosNtone | read-write | current | Specifies the vdsl Port's Down stream SOS tone degraded condition. It range from 0 to 100 units is percent. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.60 | ColumnvdslProfileUsSosMax | read-write | current | Specifies the vdsl Port's Up stream maximum number of successful SOS procedures in 120 seconds interval. It range from 0 to 15. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.61 | ColumnvdslProfileDsSosMax | read-write | current | Specifies the vdsl Port's Down stream maximum number of successful SOS procedures in 120 seconds interval. It range from 0 to 15. |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.62 | ColumnvdslProfileUpboMode | read-write | current | The identifier for VDSL UPBO |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.63 | ColumnvdslProfileUpboAValue1 | read-write | current | Specifies the vdsl Port's UPBO a value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.64 | ColumnvdslProfileUpboBValue1 | read-write | current | Specifies the vdsl Port's UPBO b value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.65 | ColumnvdslProfileUpboKl01 | read-write | current | Specifies the vdsl Port's UPBO Electrical length estimation. value is 0 or 18 ~ 635. Unit is 0.1db |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.66 | ColumnvdslProfileUpboAValue2 | read-write | current | Specifies the vdsl Port's UPBO a value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.67 | ColumnvdslProfileUpboBValue2 | read-write | current | Specifies the vdsl Port's UPBO b value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.68 | ColumnvdslProfileUpboKl02 | read-write | current | Specifies the vdsl Port's UPBO Electrical length estimation. value is 0 or 18 ~ 635. Unit is 0.1db |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.69 | ColumnvdslProfileUpboAValue3 | read-write | current | Specifies the vdsl Port's UPBO a value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.70 | ColumnvdslProfileUpboBValue3 | read-write | current | Specifies the vdsl Port's UPBO b value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.71 | ColumnvdslProfileUpboKl03 | read-write | current | Specifies the vdsl Port's UPBO Electrical length estimation. value is 0 or 18 ~ 635. Unit is 0.1db |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.72 | ColumnvdslProfileUpboAValue4 | read-write | current | Specifies the vdsl Port's UPBO a value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.73 | ColumnvdslProfileUpboBValue4 | read-write | current | Specifies the vdsl Port's UPBO b value. Unit is -1/256 |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.74 | ColumnvdslProfileUpboKl04 | read-write | current | Specifies the vdsl Port's UPBO Electrical length estimation. value is 0 or 18 ~ 635. Unit is 0.1db |
| 1.3.6.1.4.1.6296.9.102.1.5.1.1.75 | ColumnvdslProfilePtmMode | read-write | current | Specifies the vdsl Port's Ptm mode. |
| 1.3.6.1.4.1.6296.9.102.1.5.2 | TablevdslProfileRfiBandsTable | not-accessible | current | This table includes VDSL Profile RFI bands Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.5.2.1 | RowvdslProfileRfiBandsEntry | not-accessible | current | An entry in the vdslProfileRfiBandsTable. |
| 1.3.6.1.4.1.6296.9.102.1.5.2.1.1 | ColumnvdslProfileRfiBandsIndex | not-accessible | current | The identifier for VDSL RFI bands |
| 1.3.6.1.4.1.6296.9.102.1.5.2.1.2 | ColumnvdslProfileRfiBandsStartTone | read-create | current | Specifies the vdsl Port's Bands Sub-carrier start index. Unit is 1 sub-carrier (frequency = sub-carier * 4.3125kHz |
| 1.3.6.1.4.1.6296.9.102.1.5.2.1.3 | ColumnvdslProfileRfiBandsEndTone | read-create | current | Specifies the vdsl Port's Bands Sub-carrier end index. Unit is 1 sub-carrier (frequency = sub-carier * 4.3125kHz |
| 1.3.6.1.4.1.6296.9.102.1.5.2.1.4 | ColumnvdslProfileRfiBandsRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.5.3 | TablevdslProfileRfiGapsTable | not-accessible | current | This table includes VDSL Profile RFI Gaps Configuration Table. |
| 1.3.6.1.4.1.6296.9.102.1.5.3.1 | RowvdslProfileRfiGapsEntry | not-accessible | current | An entry in the vdslProfileRfiGapsTable. |
| 1.3.6.1.4.1.6296.9.102.1.5.3.1.1 | ColumnvdslProfileRfiGapsIndex | not-accessible | current | The identifier for VDSL RFI gaps |
| 1.3.6.1.4.1.6296.9.102.1.5.3.1.2 | ColumnvdslProfileRfiGapsStartTone | read-create | current | Specifies the vdsl Port's Gaps Sub-carrier start index. Unit is 1 sub-carrier (frequency = sub-carier * 4.3125kHz |
| 1.3.6.1.4.1.6296.9.102.1.5.3.1.3 | ColumnvdslProfileRfiGapsEndTone | read-create | current | Specifies the vdsl Port's Gaps Sub-carrier end index. Unit is 1 sub-carrier (frequency = sub-carier * 4.3125kHz |
| 1.3.6.1.4.1.6296.9.102.1.5.3.1.4 | ColumnvdslProfileRfiGapsRowStatus | read-create | current | The status of this conceptual row. |
| 1.3.6.1.4.1.6296.9.102.1.6 | NodegfastAutoRateLimitGroup | |||
| 1.3.6.1.4.1.6296.9.102.1.6.1 | TablegfastAutoRateLimitTable | not-accessible | current | This table includes common attributes describing gFastMIB System Port AutoRateLimit Information. |
| 1.3.6.1.4.1.6296.9.102.1.6.1.1 | RowgfastAutoRateLimitEntry | not-accessible | current | An entry in gfastPortTable. |
| 1.3.6.1.4.1.6296.9.102.1.6.1.1.1 | ColumngfastAutoRateLimitIndex | read-only | current | Specifies the gFastMIB System Port Rate-Limit Index. |
| 1.3.6.1.4.1.6296.9.102.1.6.1.1.2 | ColumngfastAutoRateLimitEgress | read-only | current | Specifies the gFastMIB System Port Rate-Limit Egress. |
| 1.3.6.1.4.1.6296.9.102.1.6.1.1.3 | ColumngfastAutoRateLimitWhich | read-only | current | Specifies the gFastMIB System Port Rate-Limit Which. |
| 1.3.6.1.4.1.6296.9.102.1.6.2 | TablegfastAutoRateLimitPercentageTable | not-accessible | current | This table includes common attributes describing gFastMIB System Port AutoRateLimitPercentage Information. |
| 1.3.6.1.4.1.6296.9.102.1.6.2.1 | RowgfastAutoRateLimitPercentageEntry | not-accessible | current | An entry in gfastAutoRateLimitPercentageTable. |
| 1.3.6.1.4.1.6296.9.102.1.6.2.1.1 | ColumngfastAutoRateLimitPercentage | read-write | current | Specifies the gfast Auto Rate-Limit Percentage. |
| 1.3.6.1.4.1.6296.9.102.2 | NodegfastCpeGroup | |||
| 1.3.6.1.4.1.6296.9.102.2.0 | NodegfastCpeNotifPrefix | |||
| 1.3.6.1.4.1.6296.9.102.2.1 | NodegfastCpeInfoGroup | |||
| 1.3.6.1.4.1.6296.9.102.2.1.1 | TablegfastCpeSystemTable | not-accessible | current | This table includes common attributes describing gFast Cpe System Information. |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1 | RowgfastCpeSystemEntry | not-accessible | current | An entry in gfastCpeSystemTable. |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.1 | ColumngfastCpeSystemIndex | read-only | current | The identifier for G.FAST CPE system |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.2 | ColumngfastCpeSystemStatus | read-write | current | Reboot the G.fast CPE |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.3 | ColumngfastCpeSystemModel | read-only | current | Display G.fast CPE model name |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.4 | ColumngfastCpeSystemHwAddr | read-only | current | Display G.fast CPE system mac address |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.5 | ColumngfastCpeSystemSerial | read-only | current | Display G.fast CPE system serial number |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.6 | ColumngfastCpeSystemHWVersion | read-only | current | Display activated G.fast CPE system H/W version |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.7 | ColumngfastCpeSystemOSVersion | read-only | current | Display activated G.fast CPE system Active OS version |
| 1.3.6.1.4.1.6296.9.102.2.1.1.1.8 | ColumngfastCpeSystemUptime | read-only | current | Display G.fast CPE system uptime |
| 1.3.6.1.4.1.6296.9.102.2.1.2 | TablegfastCpeLanStatusTable | not-accessible | current | The gfast cpe port status table |
| 1.3.6.1.4.1.6296.9.102.2.1.2.1 | RowgfastCpeLanStatusEntry | not-accessible | current | an entry of the gfast cpe port status table |
| 1.3.6.1.4.1.6296.9.102.2.1.2.1.1 | ColumngfastCpeLanIndex | read-only | current | The identifier for G.FAST CPE Lan port |
| 1.3.6.1.4.1.6296.9.102.2.1.2.1.2 | ColumngfastCpeLanName | read-only | current | Dispaly the G.FAST CPE Lan port name |
| 1.3.6.1.4.1.6296.9.102.2.1.2.1.3 | ColumngfastCpeLanAdmin | read-only | current | Display G.FAST CPE Lan port admin mode |
| 1.3.6.1.4.1.6296.9.102.2.1.2.1.4 | ColumngfastCpeLanOper | read-only | current | Display G.FAST CPE Lan port operation status |
| 1.3.6.1.4.1.6296.9.102.2.1.2.1.5 | ColumngfastCpeLanSpeed | read-only | current | Display G.FAST CPE Lan port speed |
| 1.3.6.1.4.1.6296.9.102.2.1.3 | TablegfastCpeLanCounterTable | not-accessible | current | The gfast cpe lan port packet counter table |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1 | RowgfastCpeLanCounterEntry | not-accessible | current | an entry of the gfast cpe lan port packet counter table |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.1 | ColumngfastCpeLanCounterIndex | read-only | current | The identifier for G.FAST CPE Lan port counter |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.2 | ColumngfastCpeLanInOctets | read-only | current | Display G.FAST CPE Lan port input octets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.3 | ColumngfastCpeLantInUnicast | read-only | current | Display G.FAST CPE Lan port input unicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.4 | ColumngfastCpeLanInMulticast | read-only | current | Display G.FAST CPE Lan port input multicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.5 | ColumngfastCpeLanInBroadcast | read-only | current | Display G.FAST CPE Lan port input broadcast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.6 | ColumngfastCpeLanInDiscard | read-only | current | Display G.FAST CPE Lan port input discard packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.7 | ColumngfastCpeLanInError | read-only | current | Display G.FAST CPE Lan port input error packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.8 | ColumngfastCpeLanOutOctets | read-only | current | Display G.FAST CPE Lan port output octets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.9 | ColumngfastCpeLanOutUnicast | read-only | current | Display G.FAST CPE Lan port output unicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.10 | ColumngfastCpeLanOutMulticast | read-only | current | Display G.FAST CPE Lan port output multicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.11 | ColumngfastCpeLanOutBroadcast | read-only | current | Display G.FAST CPE Lan port output broadcast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.12 | ColumngfastCpeLanOutDiscard | read-only | current | Display G.FAST CPE Lan port output discard packets |
| 1.3.6.1.4.1.6296.9.102.2.1.3.1.13 | ColumngfastCpeLanOutError | read-only | current | Display G.FAST CPE Lan port input error packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4 | TablegfastCpeWanCounterTable | not-accessible | current | The gfast cpe wan port packet counter table |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1 | RowgfastCpeWanCounterEntry | not-accessible | current | an entry of the gfast cpe wan port packet counter table |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.1 | ColumngfastCpeWanCounterIndex | read-only | current | The identifier for G.FAST CPE Wan port counter |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.2 | ColumngfastCpeWantInUnicast | read-only | current | Display G.FAST CPE Wan port input unicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.3 | ColumngfastCpeWanInMulticast | read-only | current | Display G.FAST CPE Wan port input multicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.4 | ColumngfastCpeWanInBroadcast | read-only | current | Display G.FAST CPE Wan port input broadcast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.5 | ColumngfastCpeWanInDiscard | read-only | current | Display G.FAST CPE Wan port input discard packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.6 | ColumngfastCpeWanInError | read-only | current | Display G.FAST CPE Wan port input error packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.7 | ColumngfastCpeWanOutUnicast | read-only | current | Display G.FAST CPE Wan port output unicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.8 | ColumngfastCpeWanOutMulticast | read-only | current | Display G.FAST CPE Wan port output multicast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.9 | ColumngfastCpeWanOutBroadcast | read-only | current | Display G.FAST CPE Wan port output broadcast packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.10 | ColumngfastCpeWanOutDiscard | read-only | current | Display G.FAST CPE Wan port output discard packets |
| 1.3.6.1.4.1.6296.9.102.2.1.4.1.11 | ColumngfastCpeWanOutError | read-only | current | Display G.FAST CPE Wan port input error packets |
| 1.3.6.1.4.1.6296.9.102.2.1.5 | TablegfastCpePtmCounterTable | not-accessible | current | This table includes CPE ptm packet counter |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1 | RowgfastCpePtmCounterEntry | not-accessible | current | An entry in CPE Ptm Counter Table. |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1.1 | ColumngfastCpePtmIndex | read-only | current | The identifier for G.FAST CPE ptm counter |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1.2 | ColumngfastCpePtmInPacket | read-only | current | Display G.FAST CPE ptm input packets |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1.3 | ColumngfastCpePtmInPktErr | read-only | current | Display G.FAST CPE ptm input error packets |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1.4 | ColumngfastCpePtmOutPacket | read-only | current | Display G.FAST CPE ptm output packets |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1.5 | ColumngfastCpePtmOutPktErr | read-only | current | Display G.FAST CPE ptm output error packets |
| 1.3.6.1.4.1.6296.9.102.2.1.5.1.6 | ColumngfastCpePtmFrameDrop | read-only | current | Display G.FAST CPE ptm drop frame |
| 1.3.6.1.4.1.6296.9.102.2.1.6 | TablegfastCpeStatCounterTable | not-accessible | current | This table includes CPE G.fast statistics counter. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1 | RowgfastCpeStatCounterEntry | not-accessible | current | An entry in CPE Statistics Counter Table. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.1 | ColumngfastCpeStatIndex | read-only | current | The identifier for G.FAST CPE Port's statistics. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.2 | ColumngfastCpeStatDsFec | read-only | current | Display G.FAST CPE Port's Down Stream Forward Error Correction Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.3 | ColumngfastCpeStatUsFec | read-only | current | Display G.FAST CPE Port's Up Stream Forward Error Correction Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.4 | ColumngfastCpeStatDsCrc | read-only | current | Display G.FAST CPE Port's Down Stream Cyclic Redundancy Checking. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.5 | ColumngfastCpeStatUsCrc | read-only | current | Display G.FAST CPE Port's Up Stream Cyclic Redundancy Checking. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.6 | ColumngfastCpeStatDsEss | read-only | current | Display G.FAST CPE Port's Down Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.7 | ColumngfastCpeStatUsEss | read-only | current | Display G.FAST CPE Port's Up Stream Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.8 | ColumngfastCpeStatDsSes | read-only | current | Display G.FAST CPE Port's Down Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.9 | ColumngfastCpeStatUsSes | read-only | current | Display G.FAST CPE Port's Up Stream Severely Errored Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.10 | ColumngfastCpeStatDsUas | read-only | current | Display G.FAST CPE Port's Down Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.11 | ColumngfastCpeStatUsUas | read-only | current | Display G.FAST CPE Port's Up Stream Unavailable Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.12 | ColumngfastCpeStatDsLoss | read-only | current | Display G.FAST CPE Port's Down Stream Loss of Signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.13 | ColumngfastCpeStatUsLoss | read-only | current | Display G.FAST CPE Port's Up Stream Loss of Signal Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.14 | ColumngfastCpeStatDsLofs | read-only | current | Display G.FAST CPE Port's Down Stream Loss Of Frame Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.15 | ColumngfastCpeStatUsLofs | read-only | current | Display G.FAST CPE Port's Up Stream Loss Of Frame Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.16 | ColumngfastCpeStatDsLoms | read-only | current | Display G.FAST CPE Port's Down Stream LOM Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.17 | ColumngfastCpeStatUsLoms | read-only | current | Display G.FAST CPE Port's Up Stream LOM Seconds. |
| 1.3.6.1.4.1.6296.9.102.2.1.6.1.18 | ColumngfastCpeStatRetrain | read-only | current | Display G.FAST CPE Port's Count of total retrains. |
| 1.3.6.1.4.1.6296.9.102.2.1.7 | TablegfastCpeMacTable | not-accessible | current | This table includes G.FAST CPE mac address table |
| 1.3.6.1.4.1.6296.9.102.2.1.7.1 | RowgfastCpeMacEntry | not-accessible | current | An entry in G.FAST CPE mac address Table |
| 1.3.6.1.4.1.6296.9.102.2.1.7.1.1 | ColumngfastCpeMacIndex | read-only | current | The identifier for G.FAST CPE mac address table |
| 1.3.6.1.4.1.6296.9.102.2.1.7.1.2 | ColumngfastCpeMacAddr | read-only | current | Display G.FAST CPE learning mac address |
| 1.3.6.1.4.1.6296.9.102.2.1.7.1.3 | ColumngfastCpeMacPort | read-only | current | Display G.FAST CPE learning port |
| 1.3.6.1.4.1.6296.9.102.2.1.8 | TablegfastCpeIgsTable | not-accessible | current | This table includes G.FAST CPE IGMP snooping group table |
| 1.3.6.1.4.1.6296.9.102.2.1.8.1 | RowgfastCpeIgsEntry | not-accessible | current | An entry in G.FAST CPE IGMP snooping group table |
| 1.3.6.1.4.1.6296.9.102.2.1.8.1.1 | ColumngfastCpeIgsIndex | read-only | current | The identifier for G.FAST CPE IGMP snooping group table |
| 1.3.6.1.4.1.6296.9.102.2.1.8.1.2 | ColumngfastCpeIgsGrpAddress | read-only | current | Display G.FAST CPE IGMP snooping group address |
| 1.3.6.1.4.1.6296.9.102.2.1.8.1.3 | ColumngfastCpeIgsGrpPortMask | read-only | current | Display G.FAST CPE IGMP snooping group port mask |
| 1.3.6.1.4.1.6296.9.102.2.1.9 | TablegfastCpeRateLimitTable | not-accessible | current | The gfast cpe port Rate Limit table |
| 1.3.6.1.4.1.6296.9.102.2.1.9.1 | RowgfastCpeRateLimitEntry | not-accessible | current | an entry of the gfast cpe port Rate Limit table |
| 1.3.6.1.4.1.6296.9.102.2.1.9.1.1 | ColumngfastCpeRateLimitIndex | read-only | current | The identifier for G.FAST CPE port. |
| 1.3.6.1.4.1.6296.9.102.2.1.9.1.2 | ColumngfastCpeRateLimitEgress | read-write | current | Specifies the G.FAST CPE Lan port Rate Limit Egress. range is 64 to 1048000. unit is 1Kbps. (steps of 64Kbps) |
| 1.3.6.1.4.1.6296.9.102.2.1.10 | NodegfastCpeVlan | |||
| 1.3.6.1.4.1.6296.9.102.2.1.10.1 | TablegfastCpeVlanTable | not-accessible | current | The gfast cpe port vlan table. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.1.1 | RowgfastCpeVlanEntry | not-accessible | current | An entry of the gfast cpe port vlan table. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.1.1.1 | ColumngfastCpeVlanIndex | read-only | current | The vlan index. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.1.1.2 | ColumngfastCpeVlanId | read-only | current | The vlan-identifier of G.FAST CPE port. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.1.1.3 | ColumngfastCpeVlanMemberPort | read-only | current | The identifier for G.FAST CPE member port. ex) 1 | 1,4 | 1-4 (1-4 : LAN port, 5 : WAN port) |
| 1.3.6.1.4.1.6296.9.102.2.1.10.1.1.4 | ColumngfastCpeVlanUntagPort | read-only | current | The identifier for G.FAST CPE untag port. ex) 1 | 1,4 | 1-4 (1-4 : LAN port, 5 : WAN port) |
| 1.3.6.1.4.1.6296.9.102.2.1.10.2 | NodegfastCpeVlanControl | |||
| 1.3.6.1.4.1.6296.9.102.2.1.10.2.1 | ScalargfastCpeVlanControlRequest | read-write | current | setCpeVlan: gfastCpeVlanControlSystemPort gfastCpeVlanControlVlanId gfastCpeVlanControlCpeMemberPort gfastCpeVlanControlCpeUntagPort destroyCpeVlan: gfastCpeVl… |
| 1.3.6.1.4.1.6296.9.102.2.1.10.2.2 | ScalargfastCpeVlanControlSystemPort | read-write | current | The identifier for G.FAST CPE system port. ex) 1 | 1,4 | 1-4 |
| 1.3.6.1.4.1.6296.9.102.2.1.10.2.3 | ScalargfastCpeVlanControlVlanId | read-write | current | The vlan-identifier of G.FAST CPE port. ex) 1 | 1,4 | 1-4 (max vlan count : 16) |
| 1.3.6.1.4.1.6296.9.102.2.1.10.2.4 | ScalargfastCpeVlanControlMemberPort | read-write | current | The identifier for G.FAST CPE member port. ex) 1 | 1,4 | 1-4 (1-4 : LAN port, 5 : WAN port) |
| 1.3.6.1.4.1.6296.9.102.2.1.10.2.5 | ScalargfastCpeVlanControlUntagPort | read-write | current | The identifier for G.FAST CPE untag port. ex) 1 | 1,4 | 1-4 (1-4 : LAN port, 5 : WAN port) |
| 1.3.6.1.4.1.6296.9.102.2.1.10.2.6 | ScalargfastCpeVlanControlApply | read-write | current | System Apply. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.3 | TablegfastCpePvidTable | not-accessible | current | The gfast cpe port pvid table. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.3.1 | RowgfastCpePvidEntry | not-accessible | current | An entry of the gfast cpe port pvid table. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.3.1.1 | ColumngfastCpePvid | read-only | current | The PVID of G.FAST CPE port. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.4 | NodegfastCpePvidControl | |||
| 1.3.6.1.4.1.6296.9.102.2.1.10.4.1 | ScalargfastCpePvidControlRequest | read-write | current | setCpePvid: gfastCpePvidControlSystemPort gfastCpePvidControlPvid gfastCpePvidControlCpePort |
| 1.3.6.1.4.1.6296.9.102.2.1.10.4.2 | ScalargfastCpePvidControlSystemPort | read-write | current | The identifier for G.FAST CPE system port. ex) 1 | 1,4 | 1-4 |
| 1.3.6.1.4.1.6296.9.102.2.1.10.4.3 | ScalargfastCpePvidControlPvid | read-write | current | The PVID of G.FAST CPE port. |
| 1.3.6.1.4.1.6296.9.102.2.1.10.4.4 | ScalargfastCpePvidControlPort | read-write | current | The identifier for G.FAST CPE port. ex) 1 | 1,4 | 1-4 (1-4 : LAN port, 5 : WAN port) |
| 1.3.6.1.4.1.6296.9.102.2.1.10.4.5 | ScalargfastCpePvidControlApply | read-write | current | System Apply. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| EntryStatus | INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } | current | The status of a table entry. Setting this object to the value invalid(4) has the effect of invalidating the corresponding entry. That is, it effectively disassociates the mapping identified with said entry. It is an imp… |