MIB Viewer

DAVID-MIB

126 objects
No module-level DESCRIPTION found.
Imported Objects
RFC1155-SMICounter DisplayString enterprises Gauge IpAddress NetworkAddress OBJECT-TYPE TimeTicks
OIDNameAccessStatusDescription
1.3.6.1.4.1.66Nodedavid
1.3.6.1.4.1.66.1Nodeproducts
1.3.6.1.4.1.66.1.3NodedavidExpressNet
1.3.6.1.4.1.66.1.3.1NodeexNetChassis
1.3.6.1.4.1.66.1.3.1.1ScalarexNetChassisTyperead-onlymandatoryThe chassis type (option).
1.3.6.1.4.1.66.1.3.1.2ScalarexNetChassisBkplTyperead-onlymandatoryThe chassis backplane type (option).
1.3.6.1.4.1.66.1.3.1.3ScalarexNetChassisBkplRevread-onlymandatoryThe chassis backplane revision.
1.3.6.1.4.1.66.1.3.1.4ScalarexNetChassisPsTyperead-onlymandatoryThe chassis power supply type. This refers to the chassis transformer. Each module (including the Supervisor Module) has its own switching power supply.
1.3.6.1.4.1.66.1.3.1.5ScalarexNetChassisPsStatusread-onlymandatoryThe chassis power supply status. This refers t othe chassis transformer. Each module (including the Supervisor Module) has its own switching power supply. The …
1.3.6.1.4.1.66.1.3.1.7TableexNetSlotConfigTablenot-accessiblemandatoryThe chassis slot configuration table.
1.3.6.1.4.1.66.1.3.1.7.1RowexNetSlotConfigEntrynot-accessiblemandatoryDescriptions of the modules (or boards) in each slot.
1.3.6.1.4.1.66.1.3.1.7.1.1ColumnexNetSlotIndexread-onlymandatoryThe DAVID ExpressNet chassis slot number. Valid entries are 1 to exNetChassisCapacity. On the physical Concentrator boxes, the Supervisor Modules are not numbe…
1.3.6.1.4.1.66.1.3.1.7.1.2ColumnexNetBoardIdread-onlymandatoryThe unique hardware ID for the module.
1.3.6.1.4.1.66.1.3.1.7.1.3ColumnexNetBoardTyperead-onlymandatoryThe type of the module.
1.3.6.1.4.1.66.1.3.1.7.1.4ColumnexNetBoardDescrread-onlymandatoryTextual description of the module type.
1.3.6.1.4.1.66.1.3.1.7.1.40ColumnexNetBoardNumOfPortsread-onlymandatoryThe number of ports supported by the plug-in module. For a 10BASE-T Module the value is 12; for an FOIRL Module, 6; for a Supervisor Module, 1.
1.3.6.1.4.1.66.1.3.1.8ScalarexNetChassisCapacityread-onlymandatoryThe number of slots in the chassis for plug-in modules. This number will be either five or twelve for a Concentrator and two for a Hub.
1.3.6.1.4.1.66.1.3.2NodeexNetEthernet
1.3.6.1.4.1.66.1.3.2.1NodeexNetConcentrator
1.3.6.1.4.1.66.1.3.2.1.1ScalarexNetConcRetimingStatusread-onlymandatoryIndicates whether this repeater has retiming turned on. All DAVID ExpressNet repeaters implement retiming, so the value on(2) is always returned for this varia…
1.3.6.1.4.1.66.1.3.2.1.2ScalarexNetConcFrmsRxOkread-onlymandatoryA count of frames that are successfully received by the Concentrator. This counter does not include frames received with frame-too-long, runt, FCS, or alignmen…
1.3.6.1.4.1.66.1.3.2.1.3ScalarexNetConcOctetsRxOkread-onlymandatoryA count of data and padding octets in frames that are successfully received by the concentrator. This counter does not include frames received with frame-too-l…
1.3.6.1.4.1.66.1.3.2.1.4ScalarexNetConcMcastFrmsRxOkread-onlymandatoryA count of frames that are successfully received by the concentrator and are directed to an active non-broadcast group address. This counter does not include f…
1.3.6.1.4.1.66.1.3.2.1.5ScalarexNetConcBcastFrmsRxOkread-onlymandatoryA count of frames that are successfully received by the concentrator and are directed to the broadcast group address. This counter does not include frames rece…
1.3.6.1.4.1.66.1.3.2.1.6ScalarexNetConcCollsread-onlymandatoryTotal collisions involving an incoming packet on any port (link or Network Interface port) in the Concentrator. This counter increments once for each collision…
1.3.6.1.4.1.66.1.3.2.1.7ScalarexNetConcTooLongErrorsread-onlymandatoryA count of frames that are received by the Concentrator and exceed the maximum permitted frame size.
1.3.6.1.4.1.66.1.3.2.1.8ScalarexNetConcRuntErrorsread-onlymandatoryNumber of frames received by the Concentrator that have a correct preamble (including double 1), but are shorter than the minimum legal frame size of 64 bytes …
1.3.6.1.4.1.66.1.3.2.1.9ScalarexNetConcFragErrorsread-onlymandatoryFragments of packets, shorter than the minimum legal transmission size of 96 bits, that are received on the Concentrator. Fragments indicate an external noise …
1.3.6.1.4.1.66.1.3.2.1.10ScalarexNetConcAlignErrorsread-onlymandatoryNumber of frames received on the Concentrator that are byte-misaligned, such that the number of bits is not a multiple of 8. (These frames do not pass the fram…
1.3.6.1.4.1.66.1.3.2.1.11ScalarexNetConcFcsErrorsread-onlymandatoryA count of frames received by the Concentrator that are an integral number of octets in length and do not pass the frame check sequence (FCS) check. FCS errors…
1.3.6.1.4.1.66.1.3.2.1.12ScalarexNetConcLateCollErrorsread-onlymandatoryA total Concentrator count of the late collisions. The late collision counter for a port is incremented whenever a collision is detected on the port later than…
1.3.6.1.4.1.66.1.3.2.1.40ScalarexNetConcNameread-writemandatoryA descriptive string that can be used by a network administrator to name the Concentrator.
1.3.6.1.4.1.66.1.3.2.1.41ScalarexNetConcJabbersread-onlymandatoryA count of the number of times that the jabber function had to be invoked because a frame received from one of this Concentrator's ports exceeded 5 msec in dur…
1.3.6.1.4.1.66.1.3.2.1.42ScalarexNetConcSfdErrorsread-onlymandatoryAmount of activity from this Concentrator's ports where a double-zero is seen before the start-frame delimiter (double-1). (This could indicate a polarity prob…
1.3.6.1.4.1.66.1.3.2.1.43ScalarexNetConcAutoPartitionsread-onlymandatoryIndicates how often ports on this Concentrator have been automatically partitioned by the Concentrator repeater function.
1.3.6.1.4.1.66.1.3.2.1.44ScalarexNetConcOosBitRateread-onlymandatoryNumber of times that frames have been received on the Concentrator with the transmission frequency (data rate) badly out of spec. This counter is incremented w…
1.3.6.1.4.1.66.1.3.2.1.45ScalarexNetConcLinkErrorsread-onlymandatoryThis composite counter includes jabbers, auto-partitions, and start-frame delimiter errors.
1.3.6.1.4.1.66.1.3.2.1.46ScalarexNetConcFrameErrorsread-onlymandatoryThis composite counter includes frame check sequence errors, fragments, short frames, long frames, and alignment errors.
1.3.6.1.4.1.66.1.3.2.1.47ScalarexNetConcNetUtilizationread-onlymandatoryA series of ten bytes, each indicating the percentage of bandwidth utilization for a 100-millisecond interval. Together they give the bandwidth utilization for…
1.3.6.1.4.1.66.1.3.2.1.48ScalarexNetConcResetTimeStampread-onlymandatoryThe value of sysUpTime at the point that the Concentrator repeater state machine was last reset.
1.3.6.1.4.1.66.1.3.2.1.49ScalarexNetConcResetread-writemandatoryThe reset state of the Concentrator's repeater state machine. Writing a 2 will reset the Concentrator's control logic, without changing the current configurati…
1.3.6.1.4.1.66.1.3.2.2NodeexNetModule
1.3.6.1.4.1.66.1.3.2.2.1TableexNetModuleTablenot-accessiblemandatoryA list of module entries. The number of entries is given by the number of modules that are obtained by the Concentrator Slot Configuration Table.
1.3.6.1.4.1.66.1.3.2.2.1.1RowexNetModuleEntrynot-accessiblemandatoryA module entry containing objects at the module level for a particular module.
1.3.6.1.4.1.66.1.3.2.2.1.1.1ColumnexNetModuleIndexread-onlymandatoryA unique value for each module. Its value ranges between 1 and exNetChassisCapacity. The value for each module must remain constant at least from one reinitial…
1.3.6.1.4.1.66.1.3.2.2.1.1.2ColumnexNetModuleTyperead-onlymandatoryThe type of the module.
1.3.6.1.4.1.66.1.3.2.2.1.1.3ColumnexNetModuleHwVerread-onlymandatoryThe hardware configuration of the module or hub. For model 6311, 6312, and 6313 board types, the type of Network Interface provided with the board is indicated…
1.3.6.1.4.1.66.1.3.2.2.1.1.4ColumnexNetModuleStatusread-onlymandatoryThe operational status of the module. If the status is selfTestFail(3), the exNetModuleSelfTestResult will give more detailed information about the module's co…
1.3.6.1.4.1.66.1.3.2.2.1.1.5ColumnexNetModuleResetread-writemandatoryThe reset state of the module. Writing a 2 will reset the module's control logic, without changing the current configuration. Writing a 3 will reset the module…
1.3.6.1.4.1.66.1.3.2.2.1.1.6ColumnexNetModulePartStatusread-writemandatoryTells whether the module is partitioned or enabled. Writing a 2 will partition the module and 1 will enable the module.
1.3.6.1.4.1.66.1.3.2.2.1.1.7ColumnexNetModuleNmCntlStatusread-onlymandatoryTells whether the module is under network management control. DAVID ExpressNet Concentrators always return nmControl(2), since all modules are always under net…
1.3.6.1.4.1.66.1.3.2.2.1.1.8ColumnexNetModulePsStatusread-onlymandatoryThe status of the module's power supply.
1.3.6.1.4.1.66.1.3.2.2.1.1.9ColumnexNetModuleFrmsRxOkread-onlymandatoryA count of frames that are successfully received by the module. This counter does not include frames received with frame-too-long, runt, FCS, or alignment erro…
1.3.6.1.4.1.66.1.3.2.2.1.1.10ColumnexNetModuleOctetsRxOkread-onlymandatoryA count of data and padding octets in frames that are successfully received by the module. This counter does not include frames received with frame-too-long, r…
1.3.6.1.4.1.66.1.3.2.2.1.1.13ColumnexNetModuleCollsread-onlymandatoryTotal collisions involving an incoming packet on any link or the backplane connector in the module. This counter increments once for each collision involving a…
1.3.6.1.4.1.66.1.3.2.2.1.1.14ColumnexNetModuleTooLongErrorsread-onlymandatoryA count of frames that are received by the module and exceed the maximum permitted frame size.
1.3.6.1.4.1.66.1.3.2.2.1.1.15ColumnexNetModuleRuntErrorsread-onlymandatoryNumber of frames received by the module that have a correct preamble (including double 1), but are shorter than the minimum legal frame size of 64 bytes (512 b…
1.3.6.1.4.1.66.1.3.2.2.1.1.16ColumnexNetModuleAlignErrorsread-onlymandatoryNumber of frames received by the module that are byte-misaligned, such that the number of bits is not a multiple of 8. (These frames do not pass the frame chec…
1.3.6.1.4.1.66.1.3.2.2.1.1.17ColumnexNetModuleFcsErrorsread-onlymandatoryA count of frames received by the module that are an integral number of octets in length and do not pass the frame check sequence (FCS) check. FCS errors are s…
1.3.6.1.4.1.66.1.3.2.2.1.1.18ColumnexNetModuleLateCollErrorsread-onlymandatoryA module count of the late collisions on all of the module's ports. The late collision counter for a port is incremented whenever a collision is detected on th…
1.3.6.1.4.1.66.1.3.2.2.1.1.40ColumnexNetModuleNameread-writemandatoryA descriptive string that can be used by a network administrator to name the module.
1.3.6.1.4.1.66.1.3.2.2.1.1.41ColumnexNetModuleJabbersread-onlymandatoryA count of the number of times that the jabber function had to be invoked because a frame received from one of this module's ports exceeded 5 msec in duration.
1.3.6.1.4.1.66.1.3.2.2.1.1.42ColumnexNetModuleSfdErrorsread-onlymandatoryAmount of activity from this module's ports where a double-zero is seen before the start-frame delimiter (double-1). (This could indicate a polarity problem.)
1.3.6.1.4.1.66.1.3.2.2.1.1.43ColumnexNetModuleAutoPartitionsread-onlymandatoryIndicates how often ports on this module have been automatically partitioned by the module repeater function.
1.3.6.1.4.1.66.1.3.2.2.1.1.44ColumnexNetModuleOosBitRateread-onlymandatoryNumber of times that frames have been received from ports on this module with the transmission frequency (data rate) badly out of spec. This counter is increme…
1.3.6.1.4.1.66.1.3.2.2.1.1.45ColumnexNetModuleLinkErrorsread-onlymandatoryThis composite counter includes jabbers, auto-partitions, and start-frame delimiter errors.
1.3.6.1.4.1.66.1.3.2.2.1.1.46ColumnexNetModuleFrameErrorsread-onlymandatoryThis composite counter includes frame check sequence errors, fragments, short frames, long frames, and alignment errors.
1.3.6.1.4.1.66.1.3.2.2.1.1.47ColumnexNetModuleFragErrorsread-onlymandatoryFragments of packets, shorter than the minimum legal transmission size of 96 bits, that are received on the module. Fragments indicate an external noise hit (a…
1.3.6.1.4.1.66.1.3.2.2.1.1.48ColumnexNetModulePortConfigread-writemandatoryCompresses the configuration of all of this module's ports into a two-byte integer value. Sums f(x) as x goes from 1 to number of ports, where f(x) = 0 for dis…
1.3.6.1.4.1.66.1.3.2.2.1.1.49ColumnexNetModuleLinkStatConfigread-writemandatoryCompresses the link status configuration of all of this module's ports into a two-byte integer value. Sums f(x) as x goes from 1 to number of ports, where f(x)…
1.3.6.1.4.1.66.1.3.2.2.1.1.50ColumnexNetModuleResetTimeStampread-onlymandatoryThe value of sysUpTime at the point that the module repeater state machine was last reset.
1.3.6.1.4.1.66.1.3.2.2.1.1.51ColumnexNetModuleLinkStatusread-onlymandatoryCompresses the link status of all of this module's ports into a two-byte integer value. Sums f(x) as x goes from 1 to number of ports, where f(x) = 0 for port …
1.3.6.1.4.1.66.1.3.2.2.1.1.52ColumnexNetModuleFwVerread-onlymandatoryThe firmware revision of the GAP processor on the module.
1.3.6.1.4.1.66.1.3.2.2.1.1.53ColumnexNetModuleFwFeaturePkgread-onlymandatoryThe feature package associated with the GAP processor on the module.
1.3.6.1.4.1.66.1.3.2.2.1.1.54ColumnexNetModuleSelfTestResultread-onlymandatoryThe self-test result value returned by the GAP processor on the module. Zero indicates that the module passed all tests. Bits set in the result indicate error …
1.3.6.1.4.1.66.1.3.2.3NodeexNetPort
1.3.6.1.4.1.66.1.3.2.3.1TableexNetPortTablenot-accessiblemandatoryA list of port entries. The number of entries is given by knowing the number of occupied slots in the exNetSlotConfigTable and the number of ports that are on …
1.3.6.1.4.1.66.1.3.2.3.1.1RowexNetPortEntrynot-accessiblemandatoryA port entry containing objects at the port level for a particular port.
1.3.6.1.4.1.66.1.3.2.3.1.1.1ColumnexNetPortModuleIndexread-onlymandatoryA unique value for each module. Its value ranges between 1 and exNetChassisCapacity.
1.3.6.1.4.1.66.1.3.2.3.1.1.2ColumnexNetPortIndexread-onlymandatoryA unique value for each port. Its value ranges between 1 and the value of exNetBoardNumOfPorts for this module.
1.3.6.1.4.1.66.1.3.2.3.1.1.3ColumnexNetPortLinkStatusread-onlymandatoryFor 10BASE-T ports: this is the link integrity test defined by the 10BASE-T standard. If link status test is enabled, this flag indicates whether the link is a…
1.3.6.1.4.1.66.1.3.2.3.1.1.4ColumnexNetPortPartStatusread-writemandatoryIndicates whether the port is currently partitioned by the Concentrator's auto-partition protection. (The Concentrator automatically partitions a port if it is…
1.3.6.1.4.1.66.1.3.2.3.1.1.5ColumnexNetPortJabberStatusread-onlymandatoryTells whether the DTE connected to the port is jabbering (receiving a frame longer than 5 msec in duration).
1.3.6.1.4.1.66.1.3.2.3.1.1.6ColumnexNetPortFrmsRxOkread-onlymandatoryA count of frames that are successfully received by the port. This counter does not include frames received with frame-too- long, runt, FCS, or alignment error…
1.3.6.1.4.1.66.1.3.2.3.1.1.7ColumnexNetPortOctetsRxOkread-onlymandatoryA count of data and padding octets in frames that are successfully received by the port. This counter does not include frames received with frame-too-long, run…
1.3.6.1.4.1.66.1.3.2.3.1.1.10ColumnexNetPortCollsread-onlymandatoryNumber of times this port was involved in a collision with another port in the same Hub.
1.3.6.1.4.1.66.1.3.2.3.1.1.11ColumnexNetPortTooLongErrorsread-onlymandatoryA count of frames that are received by the port and exceed the maximum permitted frame size.
1.3.6.1.4.1.66.1.3.2.3.1.1.12ColumnexNetPortRuntErrorsread-onlymandatoryNumber of frames received by the port that have a correct preamble (including double 1), but are shorter than the minimum legal frame size of 64 bytes (512 bit…
1.3.6.1.4.1.66.1.3.2.3.1.1.13ColumnexNetPortAlignErrorsread-onlymandatoryNumber of frames received by the port that are byte-misaligned, such that the number of bits is not a multiple of 8. (These frames do not pass the frame check …
1.3.6.1.4.1.66.1.3.2.3.1.1.14ColumnexNetPortFcsErrorsread-onlymandatoryA count of frames received by the port that are an integral number of octets in length and do not pass the frame check sequence (FCS) check. This counter is in…
1.3.6.1.4.1.66.1.3.2.3.1.1.15ColumnexNetPortLateCollErrorsread-onlymandatoryNumber of times that a collision has been detected on this port later than 512 bit times into the transmitted packet. Late collisions are not included in the c…
1.3.6.1.4.1.66.1.3.2.3.1.1.40ColumnexNetPortNameread-writemandatoryA descriptive string that can be used by a network administrator to name the port.
1.3.6.1.4.1.66.1.3.2.3.1.1.41ColumnexNetPortJabbersread-onlymandatoryA count of the number of times that the jabber function had to be invoked because a frame received from this port exceeded 5 msec in duration.
1.3.6.1.4.1.66.1.3.2.3.1.1.42ColumnexNetPortSfdErrorsread-onlymandatoryAmount of activity from this port where a double-zero is seen before the start-frame delimiter (double-1). (This could indicate a polarity problem.)
1.3.6.1.4.1.66.1.3.2.3.1.1.43ColumnexNetPortAutoPartitionsread-onlymandatoryIndicates how often this port has been automatically partitioned by the module repeater function.
1.3.6.1.4.1.66.1.3.2.3.1.1.44ColumnexNetPortOosBitRateread-onlymandatoryNumber of times that frames have been received from this link with the transmission frequency (data rate) badly out of spec. This counter is incremented when t…
1.3.6.1.4.1.66.1.3.2.3.1.1.45ColumnexNetPortLinkErrorsread-onlymandatoryThis composite counter includes jabbers, auto-partitions, late collisions, start-frame delimiter errors, and out-of-spec bit rate errors.
1.3.6.1.4.1.66.1.3.2.3.1.1.46ColumnexNetPortFrameErrorsread-onlymandatoryThis composite counter includes frame check sequence errors, fragments, short frames, long frames, and alignment errors.
1.3.6.1.4.1.66.1.3.2.3.1.1.47ColumnexNetPortFragErrorsread-onlymandatoryFragments of packets, shorter than the minimum legal transmission size of 96 bits, that are received on this port. Fragments indicate an external noise hit (a …
1.3.6.1.4.1.66.1.3.2.3.1.1.48ColumnexNetPortTyperead-onlymandatoryThe type of the port.
1.3.6.1.4.1.66.1.3.2.3.1.1.49ColumnexNetPortMauTyperead-onlymandatoryThe type of the MAU attached to the port.
1.3.6.1.4.1.66.1.3.2.3.1.1.50ColumnexNetPortConfigread-writemandatoryThe administrative state of the port. If both transmit and receive are enabled, the port state is enabled. If both transmit and receive are disabled, the port …
1.3.6.1.4.1.66.1.3.2.3.1.1.51ColumnexNetPortLinkStatConfigread-writemandatoryThe administrative status of the link status test for this link. If both transmit and receive are enabled, the link status test is enabled. If both transmit an…
1.3.6.1.4.1.66.1.3.2.3.1.1.52ColumnexNetPortPolarityread-writemandatoryThe polarity of the port. Applies only to ports with MAU type 10BASE-T. The value other(1) is returned for other MAU types.
1.3.6.1.4.1.66.1.3.2.3.1.1.53ColumnexNetPortTransmitTestread-writemandatoryWhether or not transmit test is enabled on the link. Transmit test applies only to links of type 10BASE-T. The value other(1) is returned for other MAU types. …
1.3.6.1.4.1.66.1.3.2.4NodeexNetMgmt
1.3.6.1.4.1.66.1.3.2.4.1ScalarexNetMgmtTyperead-onlymandatoryThe DAVID ExpressNet Ethernet network management type.
1.3.6.1.4.1.66.1.3.2.4.2ScalarexNetMgmtHwVerread-onlymandatoryThe network management ICM hardware version number: 1=Rev. A, 2=Rev. B, etc.
1.3.6.1.4.1.66.1.3.2.4.3ScalarexNetMgmtFwVerread-onlymandatoryThe network management ICP firmware version.
1.3.6.1.4.1.66.1.3.2.4.4ScalarexNetMgmtSwMajorVerread-onlymandatoryThe network management major software version number, where the version number is of the form major.minor, e.g. 3.0. Refers to the ECP (External Communications…
1.3.6.1.4.1.66.1.3.2.4.5ScalarexNetMgmtSwMinorVerread-onlymandatoryThe network management minor software version number, where the version number is of the form major.minor, e.g. 3.0. Refers to the ECP.
1.3.6.1.4.1.66.1.3.2.4.6ScalarexNetMgmtStatusread-onlymandatoryIndicates that the network management is on line and operating. For the DAVID ExpressNet Concentrators, management status is always online(2).
1.3.6.1.4.1.66.1.3.2.4.7ScalarexNetMgmtModeread-writemandatoryIndicates whether the network management is operating in primary or secondary mode. Presently, all DAVID ExpressNet Concentrators return primary(1).
1.3.6.1.4.1.66.1.3.2.4.8ScalarexNetMgmtResetread-writemandatoryNetwork management reset status. Writing a 2 to this object will reset the network management (stop refreshing the watchdog timer) and restart.
1.3.6.1.4.1.66.1.3.2.4.9ScalarexNetMgmtRestartread-writemandatoryNetwork management restart status. Writing a 2 to this object will restart the network management. This initializes all the counters, rereads the EEPROM data s…
1.3.6.1.4.1.66.1.3.2.4.10ScalarexNetMgmtIpAddrread-writemandatoryThe network management's administrative IP address. This parameter will take effect ONLY after a restart (exNetMgmtRestart) or reset (exNetMgmtReset) is issued…
1.3.6.1.4.1.66.1.3.2.4.11ScalarexNetMgmtNetMaskread-writemandatoryThe network management's administrative subnet mask. This parameter will take effect ONLY after a restart (exNetMgmtRestart) or reset (exNetMgmtReset) is issue…
1.3.6.1.4.1.66.1.3.2.4.12ScalarexNetMgmtDefaultGatewayread-writemandatoryThe network management's administrative default gateway IP address. This parameter will take effect ONLY after a restart (exNetMgmtRestart) or reset (exNetMgmt…
1.3.6.1.4.1.66.1.3.2.4.17ScalarexNetMgmtBaudRateread-onlymandatoryReturns the baud rate in bits per second of the RS-232 port. Note: The Concentrators autobaud to match the device attached to the RS-232 port.
1.3.6.1.4.1.66.1.3.2.4.19ScalarexNetMgmtLocationread-writemandatoryThis is an informational string that could be used to show the physical location (i.e., area) of the network management or Concentrator. This parameter is save…
1.3.6.1.4.1.66.1.3.2.4.20TableexNetMgmtTrapReceiverTablenot-accessiblemandatoryThis entity's Trap Receiver Table (10 entries).
1.3.6.1.4.1.66.1.3.2.4.20.1RowexNetMgmtTrapReceiverEntrynot-accessiblemandatoryA destination address and community string to a particular trap receiver.
1.3.6.1.4.1.66.1.3.2.4.20.1.1ColumnexNetMgmtTrapTyperead-writemandatorySetting this object to the value invalid(2) invalidates the corresponding entry in the exNetTrapReceiverTable. That is, it effectively disassociates the addres…
1.3.6.1.4.1.66.1.3.2.4.20.1.2ColumnexNetMgmtTrapReceiverAddrread-writemandatoryIP address for trap receiver.
1.3.6.1.4.1.66.1.3.2.4.20.1.3ColumnexNetMgmtTrapReceiverCommread-writemandatoryCommunity string used for traps.
1.3.6.1.4.1.66.1.3.2.4.21ScalarexNetMgmtAuthTrapread-writemandatoryEnable or disable the use of authentication error trap generation.