MIB Viewer

DV2-MIB

2016 objects
No module-level DESCRIPTION found.
Imported Objects
groups MISSING--
GROUPS MISSINGasn -- dv2 --
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter enterprises Gauge IpAddress
RFC1213-MIBDisplayString PhysAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.251Nodenetcomm
1.3.6.1.4.1.251.1Nodeproducts
1.3.6.1.4.1.251.1.1Nodedv2
1.3.6.1.4.1.251.1.1.1Nodedv2MessageThis is used to send an arbitary text string to the NMS.
1.3.6.1.4.1.251.1.1.1Nodedv2System
1.3.6.1.4.1.251.1.1.1.1ScalarsysMemEndread-onlymandatoryThe current end of run-time allocated memory.
1.3.6.1.4.1.251.1.1.1.4ScalarsysInitialMemBread-onlymandatoryinitial number of memory items.
1.3.6.1.4.1.251.1.1.1.5ScalarsysCurrentMemBread-onlymandatoryCurrent number of memory items.
1.3.6.1.4.1.251.1.1.1.6ScalarsysInitialSemaread-onlymandatoryInitial number of semaphores.
1.3.6.1.4.1.251.1.1.1.7ScalarsysCurrentSemaread-onlymandatoryCurrent number of semaphores.
1.3.6.1.4.1.251.1.1.1.8ScalarsysInitialQItemsread-onlymandatoryInitial number of queue items.
1.3.6.1.4.1.251.1.1.1.9ScalarsysCurrentQItemsread-onlymandatoryCurrent number of queue items.
1.3.6.1.4.1.251.1.1.1.10ScalarsysInitialQsread-onlymandatoryInitial number of queues.
1.3.6.1.4.1.251.1.1.1.11ScalarsysCurrentQsread-onlymandatoryCurrent number of queues.
1.3.6.1.4.1.251.1.1.1.12ScalarsysInitialPortsread-onlymandatoryInitial number of ports.
1.3.6.1.4.1.251.1.1.1.13ScalarsysCurrentPortsread-onlymandatoryCurrent number of ports.
1.3.6.1.4.1.251.1.1.1.14ScalarsysDefaultCellModeread-onlymandatoryThis flag indicates whether the cell interface is operating in default mode. If yes(2) then this indicates that the daughter card processor is not running its …
1.3.6.1.4.1.251.1.1.1.15TablesysLinkTablenot-accessiblemandatoryThis table contains information about each link on this slot controller.
1.3.6.1.4.1.251.1.1.1.15.1RowsysLinkEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.1.15.1.1ColumnsysLkLinkNoread-onlymandatoryThe link number on the slot
1.3.6.1.4.1.251.1.1.1.15.1.2ColumnsysLkKillLinkread-writemandatorySet to restart(2) to kill this link
1.3.6.1.4.1.251.1.1.1.15.1.3ColumnsysLkStateread-onlymandatoryStatus of the link
1.3.6.1.4.1.251.1.1.1.15.1.4ColumnsysLkTxCellsread-onlymandatoryNumber of cells sent from link
1.3.6.1.4.1.251.1.1.1.15.1.5ColumnsysLkRxCellsread-onlymandatoryNumber of cells received to link
1.3.6.1.4.1.251.1.1.1.15.1.6ColumnsysLkTxRateread-onlymandatoryCells per second sent from link
1.3.6.1.4.1.251.1.1.1.15.1.7ColumnsysLkRxRateread-onlymandatoryCells per second received to link
1.3.6.1.4.1.251.1.1.1.15.1.8ColumnsysLkTxMaxRateread-onlymandatoryMaximum cells per second transmitted from link
1.3.6.1.4.1.251.1.1.1.15.1.9ColumnsysLkRxMaxRateread-onlymandatoryMaximum cells per second received to link
1.3.6.1.4.1.251.1.1.1.15.1.10ColumnsysLkResetStatsread-writemandatorySet to yes(2) to reset the link statistics
1.3.6.1.4.1.251.1.1.1.15.1.11ColumnsysLkClockSrcread-writemandatoryThis specifies where the link obtains its clock
1.3.6.1.4.1.251.1.1.1.15.1.12ColumnsysLkResetResrcread-writemandatorySet to yes(2) to reset the link resources
1.3.6.1.4.1.251.1.1.1.15.1.13ColumnsysLKEgCLPThresholdread-writemandatoryTransmit CLP1 threshold
1.3.6.1.4.1.251.1.1.1.15.1.14ColumnsysLKIgCLPThresholdread-writemandatoryReceive CLP1 threshold
1.3.6.1.4.1.251.1.1.1.15.1.15ColumnsysLKEgEFCIThresholdread-writemandatoryTransmit EFCI threshold
1.3.6.1.4.1.251.1.1.1.15.1.16ColumnsysLKIgEFCIThresholdread-writemandatoryReceive EFCI threshold
1.3.6.1.4.1.251.1.1.1.15.1.17ColumnsysLKEgLogBufferread-writemandatoryTransmit logic buffer size
1.3.6.1.4.1.251.1.1.1.15.1.18ColumnsysLKIgLogBufferread-writemandatoryReceive logic buffer size
1.3.6.1.4.1.251.1.1.1.15.1.19ColumnsysLKEgFIFODepthread-onlymandatoryTransmit FIFO Depth
1.3.6.1.4.1.251.1.1.1.15.1.20ColumnsysLKIgFIFODepthread-onlymandatoryReceive FIFO Depth
1.3.6.1.4.1.251.1.1.1.15.1.21ColumnsysLKEgMemBlockIdread-onlymandatoryTransmit Memory Block ID
1.3.6.1.4.1.251.1.1.1.15.1.22ColumnsysLKIgMemBlockIdread-onlymandatoryReceive Memory Block ID
1.3.6.1.4.1.251.1.1.1.16TablesysDbTablenot-accessiblemandatoryThis table contains information about the internal buffer pool on the slot controller.
1.3.6.1.4.1.251.1.1.1.16.1RowsysDbEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.1.16.1.1ColumnsysDbIndexread-onlymandatoryBuffer class number
1.3.6.1.4.1.251.1.1.1.16.1.2ColumnsysDbSizeread-onlymandatoryFive classes of buffers are used:- 16, 128, 368 and 1600 bytes plus 48 bytes for cells.
1.3.6.1.4.1.251.1.1.1.16.1.3ColumnsysDbInitialread-onlymandatoryThis is the initial number of buffers available.
1.3.6.1.4.1.251.1.1.1.16.1.4ColumnsysDbCurrentread-onlymandatoryThis is the current number of buffers available.
1.3.6.1.4.1.251.1.1.1.17TablesysAuthenticateTablenot-accessiblemandatoryTable containing all the authentication tuples for this agent.
1.3.6.1.4.1.251.1.1.1.17.1RowsysAuthenticateEntrynot-accessiblemandatoryAn authentication tuple. A PDU from the ipaddress specified that contains the community, will have access to this MIB.
1.3.6.1.4.1.251.1.1.1.17.1.1ColumnsysAuIndexread-writemandatoryIndex, identifying each entry in the authentication table.
1.3.6.1.4.1.251.1.1.1.17.1.2ColumnsysAuIpaddressread-writemandatoryThe network address of the manager that has authentication access to this agent.
1.3.6.1.4.1.251.1.1.1.17.1.3ColumnsysAuCommunityread-writemandatoryThe SNMP community for which the ipaddress is authenticated.
1.3.6.1.4.1.251.1.1.1.17.1.4ColumnsysAuAccessread-writemandatoryAccess permission for this ipaddress/community tuple. Write access is required for performing SNMP sets.
1.3.6.1.4.1.251.1.1.1.17.1.5ColumnsysAuSendTrapsread-writemandatorySet to send-none(2) to prevent traps being sent to this host.
1.3.6.1.4.1.251.1.1.1.17.1.6ColumnsysAuValidityread-writemandatorySet to invalid(2) to delete this row.
1.3.6.1.4.1.251.1.1.1.18ScalarsysLastTrapMessageread-onlymandatoryThis is used to contain the last trap string sent.
1.3.6.1.4.1.251.1.1.1.19ScalarsysConfigChangedread-writemandatoryThis indicates that a new <config.cfg> file is available. This should not be set by the user.
1.3.6.1.4.1.251.1.1.1.20ScalarsysConfigFileread-writemandatorySet to read(2) to re-read the <config.cfg> file. Set to write(3) to write the existing configuration to <config.cfg>.
1.3.6.1.4.1.251.1.1.1.21ScalarsysCompileTimeread-onlymandatoryDate and time of link in the form dd Mon yyyy hh:mm:ss. For example:- 15 Aug 1994 10:12:21
1.3.6.1.4.1.251.1.1.1.22ScalarslotNumberread-onlymandatorySlot Number
1.3.6.1.4.1.251.1.1.1.23ScalarsysLastResetTimeM2read-onlymandatoryDate and time board was last reset.
1.3.6.1.4.1.251.1.1.1.24ScalarsysCurrentTimeM2read-writemandatoryCurrent date and time in the form dd Mon yyyy hh:mm:ss. For example:- 15 Aug 1994 10:12:21
1.3.6.1.4.1.251.1.1.1.25ScalarlimTypeStatusread-onlymandatoryDescribes whether the lim and the DOC card are compatible.
1.3.6.1.4.1.251.1.1.2Nodedv2Slot0
1.3.6.1.4.1.251.1.1.2NodeslotChangedThis is sent when a slot changes state.
1.3.6.1.4.1.251.1.1.2.1Scalarslot0IntIpread-onlymandatoryIP address of SLOT 0 for ATM interface.
1.3.6.1.4.1.251.1.1.2.2Scalarslot0XpInUseread-onlymandatoryThe current Switch Fabric in Service
1.3.6.1.4.1.251.1.1.2.3Scalarslot0XpToUseread-writemandatoryThis indicates the switch fabric card you want the switch to use.
1.3.6.1.4.1.251.1.1.2.4Scalarslot0StandbyXpread-writemandatorySet to yes(1) to enable standby switch fabric.
1.3.6.1.4.1.251.1.1.2.5Tableslot0PsuTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.2.5.1Rowslot0PsuEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.2.5.1.1Columnslot0PsuIndexread-onlymandatoryPower-supply number.
1.3.6.1.4.1.251.1.1.2.5.1.2Columnslot0PsuFaultread-onlymandatoryIf fault(2) then this indicates a fault condition in the power-supply.
1.3.6.1.4.1.251.1.1.2.5.1.3Columnslot0PsuTestFaultread-onlymandatoryIf set to yes(1) the control button on the PSU module has been set to test fault mode.
1.3.6.1.4.1.251.1.1.2.5.1.4Columnslot0PsuVoltageread-onlymandatoryThis is a the voltage generated by the power-supply in millivolts.
1.3.6.1.4.1.251.1.1.2.5.1.5Columnslot0PsuTempread-onlymandatoryThis is the temperature of the power-supply module in degrees celsius.
1.3.6.1.4.1.251.1.1.2.5.1.6Columnslot0PsuFanASpeedread-onlymandatoryThis is the rotation speed of FAN A in RPM.
1.3.6.1.4.1.251.1.1.2.5.1.7Columnslot0PsuFanBSpeedread-onlymandatoryThis is the rotation speed of FAN B in RPM.
1.3.6.1.4.1.251.1.1.2.5.1.8Columnslot0PsuFanCSpeedread-onlymandatoryThis is the rotation speed of FAN C in RPM.
1.3.6.1.4.1.251.1.1.2.5.1.9Columnslot0PsuResetread-writemandatoryIf set to yes(2) then the power-supply module is returned to its initial state.
1.3.6.1.4.1.251.1.1.2.5.1.10Columnslot0PsuTyperead-onlymandatoryShows the type of PSU fitted into switch.
1.3.6.1.4.1.251.1.1.2.5.1.11Columnslot0PsuFanFailread-onlymandatorySet to yes(2) if the fan fails.
1.3.6.1.4.1.251.1.1.2.5.1.12Columnslot0PsuTooHotread-onlymandatorySet to yes(2) if the PSU is too hot
1.3.6.1.4.1.251.1.1.2.5.1.13Columnslot0PsuFrontTooHotread-onlymandatorySet to yes(2) if the Front is too hot
1.3.6.1.4.1.251.1.1.2.6Tableslot0PhyTablenot-accessiblemandatoryThis table summarises the hardware installed in the switch.
1.3.6.1.4.1.251.1.1.2.6.1Rowslot0PhyEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.2.6.1.1Columnslot0PhySlotNoread-onlymandatoryThis is the slot number in the switch.
1.3.6.1.4.1.251.1.1.2.6.1.2Columnslot0PhyNameread-writemandatoryThis is a mnemonic name for the slot.
1.3.6.1.4.1.251.1.1.2.6.1.3Columnslot0PhyTyperead-onlymandatoryThis enumerated type defines the type of card fitted in the slot.
1.3.6.1.4.1.251.1.1.2.6.1.4Columnslot0PhyDlimread-writemandatoryThis is the type of DLIM fitted to the slot.
1.3.6.1.4.1.251.1.1.2.6.1.5Columnslot0PhySwVerread-onlymandatoryVersion of the software running on this slot controller.
1.3.6.1.4.1.251.1.1.2.6.1.6Columnslot0PhyStateread-onlymandatoryThe state of the slot, -(1) indicates no card fitted.
1.3.6.1.4.1.251.1.1.2.6.1.7Columnslot0PhyResetread-writemandatorySetting to yes(2) will reset the slot - use with care
1.3.6.1.4.1.251.1.1.2.6.1.8Columnslot0PhyReqStateread-writemandatorySetting to shutdown(2) will stop the slot running. The slot should only be set to main(3) or shadow(4) if the slot is operating in hardware redundant mode with…
1.3.6.1.4.1.251.1.1.2.6.1.10Columnslot0PhyStateChangeread-onlymandatoryIndicates link has changed state.
1.3.6.1.4.1.251.1.1.2.6.1.11Columnslot0PhyLinkedSlotread-writemandatoryThis is used in hardware redundancy mode. If set to 0 then there is no associated slot. Otherwise the value is the slot number that will be used if this slot f…
1.3.6.1.4.1.251.1.1.2.6.1.12Columnslot0PhyLink0Stateread-onlymandatoryThis contains link 0 status.
1.3.6.1.4.1.251.1.1.2.6.1.13Columnslot0PhyLink1Stateread-onlymandatoryThis contains link 1 status.
1.3.6.1.4.1.251.1.1.2.6.1.14Columnslot0PhyLink2Stateread-onlymandatoryThis contains link 2 status.
1.3.6.1.4.1.251.1.1.2.6.1.15Columnslot0PhyLink3Stateread-onlymandatoryThis contains link 3 status.
1.3.6.1.4.1.251.1.1.2.6.1.16Columnslot0PhySlotSerNoread-onlymandatorySerial number of the slot controller.
1.3.6.1.4.1.251.1.1.2.6.1.17Columnslot0PhySlotHwVerNoread-onlymandatoryHardware version number and revision of the slot controller.
1.3.6.1.4.1.251.1.1.2.6.1.18Columnslot0PhyDocSerNoread-onlymandatorySerial number of the DOC.
1.3.6.1.4.1.251.1.1.2.6.1.19Columnslot0PhyDocHwVerNoread-onlymandatoryHardware version number and revision of the DOC.
1.3.6.1.4.1.251.1.1.2.6.1.20Columnslot0PhyMacAddressread-writemandatoryMAC address of the slot.
1.3.6.1.4.1.251.1.1.2.6.1.21Columnslot0PhyChangeTimeM2read-onlymandatoryLast date and time link changed state.
1.3.6.1.4.1.251.1.1.2.6.1.22Columnslot0PhyLstChngLnkNumread-onlymandatoryHolds the link number of the last link status to change.
1.3.6.1.4.1.251.1.1.2.6.1.23Columnslot0PhyLstChngPrevLnkStatread-onlymandatoryHolds the previous link state of the last link number whose status changed.
1.3.6.1.4.1.251.1.1.2.7Scalarslot0MaxUpSlotsread-onlymandatoryThe maximum number of slots that have been up.
1.3.6.1.4.1.251.1.1.2.8Scalarslot0CurrentUpSlotsread-onlymandatoryThe number of slots currently up.
1.3.6.1.4.1.251.1.1.2.9Scalarslot0IsStandbySlot0read-onlymandatorySet to yes(2) if there is a redundant slot 0 available.
1.3.6.1.4.1.251.1.1.2.10Scalarslot0TftpToStandbyread-writemandatorySet to no(2) to stop files being transferred to the out of service slot0 automatically when they are changed.
1.3.6.1.4.1.251.1.1.2.11Scalarslot0MibBroadcastread-writemandatoryBroadcasts particular tables to all other slots.
1.3.6.1.4.1.251.1.1.2.14Scalarslot0Addressread-writemandatoryThe E.164 address of the switch.
1.3.6.1.4.1.251.1.1.2.15Scalarslot0InUseread-onlymandatoryThe Slot 0 card Redundancy Status.
1.3.6.1.4.1.251.1.1.2.16Scalarslot0ToUseread-writemandatoryThis indicates the Slot 0 card you want the switch to use.
1.3.6.1.4.1.251.1.1.2.17Scalarslot0redmoderead-onlymandatoryThe Slot 0 card Redundancy mode.
1.3.6.1.4.1.251.1.1.2.18Scalarslot0IntIPMaskread-writemandatoryIP Mask for Internal Subnet. To reconfigure, Save new configuration and perform then warm Start.
1.3.6.1.4.1.251.1.1.2.19Scalarslot0SwitchIdread-writemandatorySwitch ID for this Apex node
1.3.6.1.4.1.251.1.1.2.20Scalarntms0docread-writemandatorySignifies that the S0DOC is capable of communicating with an NTM
1.3.6.1.4.1.251.1.1.2.21Scalarslot0LecsPrefixread-writemandatoryThe NSAP network prefix for LECS.
1.3.6.1.4.1.251.1.1.2.22Scalarslot0LecsESIread-writemandatoryThe NSAP ESI for LECS.
1.3.6.1.4.1.251.1.1.3Nodedv2Trace
1.3.6.1.4.1.251.1.1.3NodelinkChangedThis is sent when a link changes state.
1.3.6.1.4.1.251.1.1.3.1ScalartraceIpread-writemandatoryToggle for IP trace flag.
1.3.6.1.4.1.251.1.1.3.2ScalartraceUdpread-writemandatoryToggle for UDP trace flag.
1.3.6.1.4.1.251.1.1.3.3ScalartraceTcpread-writemandatoryToggle for TCP trace flag.
1.3.6.1.4.1.251.1.1.3.4ScalartraceSnmpread-writemandatoryToggle for SNMP trace flag.
1.3.6.1.4.1.251.1.1.3.5ScalartraceCatread-writemandatoryToggle for CAT trace flag.
1.3.6.1.4.1.251.1.1.4Nodedv2SlipLine
1.3.6.1.4.1.251.1.1.4NodepsuChangedThis is sent when a power supply changes state.
1.3.6.1.4.1.251.1.1.4.1ScalarslipIpread-writemandatoryIP address of SLIP line.
1.3.6.1.4.1.251.1.1.4.2ScalarslipMaskread-writemandatoryMask for SLIP line.
1.3.6.1.4.1.251.1.1.4.3ScalarslipRemoteIpread-writemandatoryIP address of remote end of SLIP line.
1.3.6.1.4.1.251.1.1.4.4ScalarslipSpeedread-writemandatoryBaud rate of SLIP serial line.
1.3.6.1.4.1.251.1.1.5NodeconfigChangedThis is sent when <config.cfg> has changed.
1.3.6.1.4.1.251.1.1.5Nodedv2StaticRoute
1.3.6.1.4.1.251.1.1.6Nodedv2Clocks
1.3.6.1.4.1.251.1.1.6.1ScalarclksTxTimingRefread-writemandatoryTransmit Timing Reference
1.3.6.1.4.1.251.1.1.6.2ScalarclksSysRefSlotNumread-writemandatorySystem Timing Reference Slot Number
1.3.6.1.4.1.251.1.1.6.3ScalarclksSysRefLinkNumread-writemandatorySystem Timing Reference Link Number
1.3.6.1.4.1.251.1.1.6.4ScalarclksSysRefErrorread-onlymandatorySystem Timing Error
1.3.6.1.4.1.251.1.1.8Nodedv2VcDoc
1.3.6.1.4.1.251.1.1.8.1TablevcDocTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.8.1.1RowvcDocEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.8.1.1.1ColumnvcDocLinkNoread-onlymandatoryThis is the target link number for the PVC.
1.3.6.1.4.1.251.1.1.8.1.1.2ColumnvcDocEnableread-writemandatorySetting to yes(1) enables the VCDOC channel.
1.3.6.1.4.1.251.1.1.8.1.1.3ColumnvcDocVpiread-onlymandatoryVPI of the VC being used for cell transfers.
1.3.6.1.4.1.251.1.1.8.1.1.4ColumnvcDocVciread-onlymandatoryVCI of the VC being used for cell transfers.
1.3.6.1.4.1.251.1.1.8.1.1.5ColumnvcDocLinkSpeedread-writemandatoryThis sets the speed at which the link is to run.
1.3.6.1.4.1.251.1.1.8.1.1.6ColumnvcDocCLinesread-writemandatoryThis sets how control lines should be processed. If Ignore(2) is set then the port is always online.
1.3.6.1.4.1.251.1.1.8.1.1.7ColumnvcDocFifoSizeread-writemandatoryThis is the size of the software emulated FIFO.
1.3.6.1.4.1.251.1.1.8.1.1.8ColumnvcDocLowWaterread-writemandatoryThis is the point at which the transmit clock is switched to low frequency. This must be between 0 and FIFO Size/2
1.3.6.1.4.1.251.1.1.8.1.1.9ColumnvcDocHighWaterread-writemandatoryThis is the point at which the transmit clock is switched to high frequency. This must be between FIFO size and FIFO Size/2
1.3.6.1.4.1.251.1.1.8.1.1.10ColumnvcDocTestModeread-writemandatoryThis is the type of self-test to perform with the VC DOC.
1.3.6.1.4.1.251.1.1.8.1.1.11ColumnvcDocTestValread-writemandatoryThis is the test value to use when doing the pattern-send test.
1.3.6.1.4.1.251.1.1.8.1.1.12ColumnvcDocPriorityread-onlymandatoryThis indicates that cells will be sent with the priority bit set.
1.3.6.1.4.1.251.1.1.8.1.1.13ColumnvcDocSubaread-onlymandatoryThis is the target link number for the VC.
1.3.6.1.4.1.251.1.1.8.1.1.14ColumnvcDocSaddrread-onlymandatoryThis is the target slot number for the VC.
1.3.6.1.4.1.251.1.1.8.1.1.15ColumnvcDocClockFixread-writemandatoryIf yes(2) then the clock will not be varied to maintain the size of the send FIFO.
1.3.6.1.4.1.251.1.1.8.2TablevcStatTablenot-accessiblemandatoryThis is a two row table that contains status information about the VCDOC.
1.3.6.1.4.1.251.1.1.8.2.1RowvcStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.8.2.1.1ColumnvcStatPortNoread-onlymandatoryThis is the originating port number for the PVC
1.3.6.1.4.1.251.1.1.8.2.1.2ColumnvcStatRxStateread-onlymandatoryThis indicates whether control lines are high at the other end of the link.
1.3.6.1.4.1.251.1.1.8.2.1.3ColumnvcStatTxStateread-onlymandatoryThis indicates whether the local control lines are high.
1.3.6.1.4.1.251.1.1.8.2.1.4ColumnvcStatFifoCountread-onlymandatoryThis indicates the number of cells waiting in the FIFO.
1.3.6.1.4.1.251.1.1.8.2.1.5ColumnvcStatOFlowread-onlymandatoryNumber of Overflows.
1.3.6.1.4.1.251.1.1.8.2.1.6ColumnvcStatUFlowread-onlymandatoryNumber of Underflows.
1.3.6.1.4.1.251.1.1.8.2.1.7ColumnvcStatReSyncread-onlymandatoryThis is the number of times a sequence number resync has been required.
1.3.6.1.4.1.251.1.1.8.2.1.8ColumnvcStatInventedread-onlymandatoryNumber of invented cells.
1.3.6.1.4.1.251.1.1.8.2.1.9ColumnvcStatRxCellsread-onlymandatoryReceived cells count.
1.3.6.1.4.1.251.1.1.8.2.1.10ColumnvcStatTxCellsread-onlymandatoryTransmitted cells count.
1.3.6.1.4.1.251.1.1.8.2.1.11ColumnvcStatRxSeqNoread-onlymandatoryReceive current sequence number.
1.3.6.1.4.1.251.1.1.8.2.1.12ColumnvcStatTxSeqNoread-onlymandatoryTransmit current sequence number.
1.3.6.1.4.1.251.1.1.8.2.1.13ColumnvcStatLastErrorread-onlymandatoryLast error type.
1.3.6.1.4.1.251.1.1.8.2.1.14ColumnvcStatLastCompareread-onlymandatoryLast compare value.
1.3.6.1.4.1.251.1.1.8.2.1.15ColumnvcStatTestErrorsread-onlymandatoryNumber of test errors detected.
1.3.6.1.4.1.251.1.1.9Nodedv2FrRelay
1.3.6.1.4.1.251.1.1.9.1TablefRelayStatTablenot-accessiblemandatoryThis contains the overall status information for the frame relay links.
1.3.6.1.4.1.251.1.1.9.1.1RowfRelayStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.1.1.1ColumnfRelStatLinkNoread-onlymandatoryLocal send sequence.
1.3.6.1.4.1.251.1.1.9.1.1.2ColumnfRelStatLocSeqread-onlymandatoryLocal send sequence.
1.3.6.1.4.1.251.1.1.9.1.1.3ColumnfRelStatLocAckread-onlymandatoryLocal ack sequence.
1.3.6.1.4.1.251.1.1.9.1.1.4ColumnfRelStatLocStateread-onlymandatoryLocal state of link.
1.3.6.1.4.1.251.1.1.9.1.1.5ColumnfRelStatLocStartTread-onlymandatoryLocal start time for poll.
1.3.6.1.4.1.251.1.1.9.1.1.6ColumnfRelStatLocErrThrread-onlymandatoryLocal error threshold Counter.
1.3.6.1.4.1.251.1.1.9.1.1.7ColumnfRelStatLocMecread-onlymandatoryLocal monitored events Counter.
1.3.6.1.4.1.251.1.1.9.1.1.8ColumnfRelStatLocPollread-onlymandatoryLocal poll Counter for DTE.
1.3.6.1.4.1.251.1.1.9.1.1.9ColumnfRelStatRemSeqread-onlymandatoryRemote send sequence.
1.3.6.1.4.1.251.1.1.9.1.1.10ColumnfRelStatRemAckread-onlymandatoryRemote ack sequence.
1.3.6.1.4.1.251.1.1.9.1.1.11ColumnfRelStatRemStateread-onlymandatoryRemote state of link.
1.3.6.1.4.1.251.1.1.9.1.1.12ColumnfRelStatRemStartTread-onlymandatoryRemote start time for poll.
1.3.6.1.4.1.251.1.1.9.1.1.13ColumnfRelStatRemErrThrread-onlymandatoryRemote error threshold Counter.
1.3.6.1.4.1.251.1.1.9.1.1.14ColumnfRelStatRemMecread-onlymandatoryRemote monitored events Counter.
1.3.6.1.4.1.251.1.1.9.1.1.15ColumnfRelStatRemPollread-onlymandatoryRemote poll Counter for DTE.
1.3.6.1.4.1.251.1.1.9.2TablefRelayConfTablenot-accessiblemandatoryThis table contains the overall configuration for the frame relay links.
1.3.6.1.4.1.251.1.1.9.2.1RowfRelayConfEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.2.1.1ColumnfRelConfLinkNoread-onlymandatoryNumber of the link to configure.
1.3.6.1.4.1.251.1.1.9.2.1.2ColumnfRelConfLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.9.2.1.3ColumnfRelConfLinkModeread-writemandatoryframe mode.
1.3.6.1.4.1.251.1.1.9.2.1.4ColumnfRelConfLinkSpeedread-writemandatoryLocal speed of link.
1.3.6.1.4.1.251.1.1.9.2.1.5ColumnfRelConfLinkClineread-writemandatorySet to no(2) to disable control line processing.
1.3.6.1.4.1.251.1.1.9.2.1.6ColumnfRelConfLinkTyperead-writemandatoryType of link.
1.3.6.1.4.1.251.1.1.9.2.1.7ColumnfRelConfN391read-writemandatoryPoll count.
1.3.6.1.4.1.251.1.1.9.2.1.8ColumnfRelConfN392read-writemandatoryThreshold.
1.3.6.1.4.1.251.1.1.9.2.1.9ColumnfRelConfN393read-writemandatoryMonitored events.
1.3.6.1.4.1.251.1.1.9.2.1.10ColumnfRelConfT391read-writemandatoryPoll period.
1.3.6.1.4.1.251.1.1.9.2.1.11ColumnfRelConfT392read-writemandatoryPoll timeout.
1.3.6.1.4.1.251.1.1.9.3TablefraPStatTablenot-accessiblemandatoryThis shows the status of the frame relay PVCs for link 0.
1.3.6.1.4.1.251.1.1.9.3.1RowfraPStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.3.1.1ColumnfraPStatDlciread-onlymandatoryThis is the DLCI for the PVC.
1.3.6.1.4.1.251.1.1.9.3.1.2ColumnfraPStatRxBCntread-onlymandatoryThe number of bytes received.
1.3.6.1.4.1.251.1.1.9.3.1.3ColumnfraPStatTxBCntread-onlymandatoryThe number of bytes transmitted.
1.3.6.1.4.1.251.1.1.9.3.1.4ColumnfraPStatRxFCntread-onlymandatoryThe number of frames received.
1.3.6.1.4.1.251.1.1.9.3.1.5ColumnfraPStatTxFCntread-onlymandatoryThe number of frames transmitted.
1.3.6.1.4.1.251.1.1.9.3.1.6ColumnfraPStatRxBRateread-onlymandatoryThe rate of bytes being received.
1.3.6.1.4.1.251.1.1.9.3.1.7ColumnfraPStatTxBRateread-onlymandatoryThe rate of bytes being transmitted.
1.3.6.1.4.1.251.1.1.9.3.1.8ColumnfraPStatRxFRateread-onlymandatoryThe rate of frames being received.
1.3.6.1.4.1.251.1.1.9.3.1.9ColumnfraPStatTxFRateread-onlymandatoryThe rate of frames being transmitted.
1.3.6.1.4.1.251.1.1.9.3.1.10ColumnfraPStatDERxFread-onlymandatoryThe count of discarded eligible received frames.
1.3.6.1.4.1.251.1.1.9.3.1.11ColumnfraPStatDisRxFread-onlymandatoryThe count of discarded received frames.
1.3.6.1.4.1.251.1.1.9.3.1.12ColumnfraPStatPvcStatread-onlymandatoryThe state of the PVC.
1.3.6.1.4.1.251.1.1.9.3.1.13ColumnfraPStatLinkStateread-onlymandatoryThe state of the link.
1.3.6.1.4.1.251.1.1.9.3.1.14ColumnfraPStatLocSeqread-onlymandatoryThe local send sequence.
1.3.6.1.4.1.251.1.1.9.3.1.15ColumnfraPStatLocAckread-onlymandatoryThe local acknowledge number.
1.3.6.1.4.1.251.1.1.9.3.1.16ColumnfraPStatLocStatread-onlymandatoryThe local state of the link.
1.3.6.1.4.1.251.1.1.9.3.1.17ColumnfraPStatLocStartTread-onlymandatoryThe local start time for poll.
1.3.6.1.4.1.251.1.1.9.3.1.18ColumnfraPStatLocErrThrread-onlymandatoryThe local error threshold Counter.
1.3.6.1.4.1.251.1.1.9.3.1.19ColumnfraPStatLocMecread-onlymandatoryThe local monitored event Counter.
1.3.6.1.4.1.251.1.1.9.3.1.20ColumnfraPStatLocPollread-onlymandatoryThe local poll Counter for DTE.
1.3.6.1.4.1.251.1.1.9.3.1.21ColumnfraPStatRemSeqread-onlymandatoryThe remote send sequence.
1.3.6.1.4.1.251.1.1.9.3.1.22ColumnfraPStatRemAckread-onlymandatoryThe remote acknowledge number.
1.3.6.1.4.1.251.1.1.9.3.1.23ColumnfraPStatRemStatread-onlymandatoryThe remote state of the link.
1.3.6.1.4.1.251.1.1.9.3.1.24ColumnfraPStatRemStartTread-onlymandatoryThe remote start time for poll.
1.3.6.1.4.1.251.1.1.9.3.1.25ColumnfraPStatRemErrThrread-onlymandatoryThe remote error threshold Counter.
1.3.6.1.4.1.251.1.1.9.3.1.26ColumnfraPStatRemMecread-onlymandatoryThe remote monitored event Counter.
1.3.6.1.4.1.251.1.1.9.3.1.27ColumnfraPStatRemPollread-onlymandatoryThe remote poll Counter for DTE.
1.3.6.1.4.1.251.1.1.9.3.1.29ColumnfraPStatLastChangeM2read-onlymandatoryThe date and time of last state change.
1.3.6.1.4.1.251.1.1.9.4TablefraPConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.4.1RowfraPConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.4.1.1ColumnfraPConfigDlciread-writemandatoryThis is the DLCI for the PVC.
1.3.6.1.4.1.251.1.1.9.4.1.2ColumnfraPConfigCirread-writemandatoryThe committed information rate.
1.3.6.1.4.1.251.1.1.9.4.1.3ColumnfraPConfigCommitBread-writemandatoryThe committed burst rate.
1.3.6.1.4.1.251.1.1.9.4.1.4ColumnfraPConfigExcessBread-writemandatoryThe excess burst size.
1.3.6.1.4.1.251.1.1.9.4.1.5ColumnfraVpiread-onlymandatoryThe VPI for this call.
1.3.6.1.4.1.251.1.1.9.4.1.6ColumnfraVciread-onlymandatoryThe VCI for the call.
1.3.6.1.4.1.251.1.1.9.4.1.7ColumnfraPConfigPriorityread-onlymandatory
1.3.6.1.4.1.251.1.1.9.4.1.8ColumnfraPConfigSubaread-onlymandatory
1.3.6.1.4.1.251.1.1.9.4.1.9ColumnfraPConfigSaddrread-onlymandatory
1.3.6.1.4.1.251.1.1.9.4.1.10ColumnfraPConfigValidityread-writemandatoryProvides a way of deleting a row in the table when set to invalid.
1.3.6.1.4.1.251.1.1.9.4.1.11ColumnfraPConfigDxivpiread-writemandatoryThis is the VPI for the PVC
1.3.6.1.4.1.251.1.1.9.4.1.12ColumnfraPConfigDxivciread-writemandatoryThis is the VCI for the PVC
1.3.6.1.4.1.251.1.1.9.4.1.13ColumnfraPConfigDximoderead-writemandatoryThis flag indicates whether the mode is DXI - in that case the value of DLCI is ignored
1.3.6.1.4.1.251.1.1.9.5TablefrbPStatTablenot-accessiblemandatoryThis table shows statistics about the Frame Relay PVCs for link 1.
1.3.6.1.4.1.251.1.1.9.5.1RowfrbPStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.5.1.1ColumnfrbPStatDlciread-onlymandatoryThis is the DLCI for the PVC.
1.3.6.1.4.1.251.1.1.9.5.1.2ColumnfrbPStatRxBCntread-onlymandatoryThe number of bytes received.
1.3.6.1.4.1.251.1.1.9.5.1.3ColumnfrbPStatTxBCntread-onlymandatoryThe number of bytes transmitted.
1.3.6.1.4.1.251.1.1.9.5.1.4ColumnfrbPStatRxFCntread-onlymandatoryThe number of frames received.
1.3.6.1.4.1.251.1.1.9.5.1.5ColumnfrbPStatTxFCntread-onlymandatoryThe number of frames transmitted.
1.3.6.1.4.1.251.1.1.9.5.1.6ColumnfrbPStatRxBRateread-onlymandatoryThe rate of bytes being received.
1.3.6.1.4.1.251.1.1.9.5.1.7ColumnfrbPStatTxBRateread-onlymandatoryThe rate of bytes being transmitted.
1.3.6.1.4.1.251.1.1.9.5.1.8ColumnfrbPStatRxFRateread-onlymandatoryThe rate of frames being received.
1.3.6.1.4.1.251.1.1.9.5.1.9ColumnfrbPStatTxFRateread-onlymandatoryThe rate of frames being transmitted.
1.3.6.1.4.1.251.1.1.9.5.1.10ColumnfrbPStatDERxFread-onlymandatoryThe count of discarded eligible received frames.
1.3.6.1.4.1.251.1.1.9.5.1.11ColumnfrbPStatDisRxFread-onlymandatoryThe count of discarded received frames.
1.3.6.1.4.1.251.1.1.9.5.1.12ColumnfrbPStatPvcStatread-onlymandatoryThe state of the PVC.
1.3.6.1.4.1.251.1.1.9.5.1.13ColumnfrbPStatLinkStateread-onlymandatoryThe state of the link.
1.3.6.1.4.1.251.1.1.9.5.1.14ColumnfrbPStatLocSeqread-onlymandatoryThe local send sequence.
1.3.6.1.4.1.251.1.1.9.5.1.15ColumnfrbPStatLocAckread-onlymandatoryThe local acknowledge number.
1.3.6.1.4.1.251.1.1.9.5.1.16ColumnfrbPStatLocStatread-onlymandatoryThe local state of the link.
1.3.6.1.4.1.251.1.1.9.5.1.17ColumnfrbPStatLocStartTread-onlymandatoryThe local start time for poll.
1.3.6.1.4.1.251.1.1.9.5.1.18ColumnfrbPStatLocErrThrread-onlymandatoryThe local error threshold Counter.
1.3.6.1.4.1.251.1.1.9.5.1.19ColumnfrbPStatLocMecread-onlymandatoryThe local monitored event Counter.
1.3.6.1.4.1.251.1.1.9.5.1.20ColumnfrbPStatLocPollread-onlymandatoryThe local poll Counter for DTE.
1.3.6.1.4.1.251.1.1.9.5.1.21ColumnfrbPStatRemSeqread-onlymandatoryThe remote send sequence.
1.3.6.1.4.1.251.1.1.9.5.1.22ColumnfrbPStatRemAckread-onlymandatoryThe remote acknowledge number.
1.3.6.1.4.1.251.1.1.9.5.1.23ColumnfrbPStatRemStatread-onlymandatoryThe remote state of the link.
1.3.6.1.4.1.251.1.1.9.5.1.24ColumnfrbPStatRemStartTread-onlymandatoryThe remote start time for poll.
1.3.6.1.4.1.251.1.1.9.5.1.25ColumnfrbPStatRemErrThrread-onlymandatoryThe remote error threshold Counter.
1.3.6.1.4.1.251.1.1.9.5.1.26ColumnfrbPStatRemMecread-onlymandatoryThe remote monitored event Counter.
1.3.6.1.4.1.251.1.1.9.5.1.27ColumnfrbPStatRemPollread-onlymandatoryThe remote poll Counter for DTE.
1.3.6.1.4.1.251.1.1.9.5.1.29ColumnfrbPStatLastChangeM2read-onlymandatoryThe date and time of last state change.
1.3.6.1.4.1.251.1.1.9.6TablefrbPConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.6.1RowfrbPConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.9.6.1.1ColumnfrbPConfigDlciread-writemandatoryThis is the DLCI for the PVC.
1.3.6.1.4.1.251.1.1.9.6.1.2ColumnfrbPConfigCirread-writemandatoryThe committed information rate.
1.3.6.1.4.1.251.1.1.9.6.1.3ColumnfrbPConfigCommitBread-writemandatoryThe committed burst rate.
1.3.6.1.4.1.251.1.1.9.6.1.4ColumnfrbPConfigExcessBread-writemandatoryThe excess burst size.
1.3.6.1.4.1.251.1.1.9.6.1.5ColumnfrbVpiread-onlymandatoryThe VPI for this call.
1.3.6.1.4.1.251.1.1.9.6.1.6ColumnfrbVciread-onlymandatoryThe VCI for the call.
1.3.6.1.4.1.251.1.1.9.6.1.7ColumnfrbPConfigPriorityread-onlymandatory
1.3.6.1.4.1.251.1.1.9.6.1.8ColumnfrbPConfigSubaread-onlymandatory
1.3.6.1.4.1.251.1.1.9.6.1.9ColumnfrbPConfigSaddrread-onlymandatory
1.3.6.1.4.1.251.1.1.9.6.1.10ColumnfrbPConfigValidityread-writemandatoryProvides a way of deleting a row in the table when set to invalid.
1.3.6.1.4.1.251.1.1.9.6.1.11ColumnfrbPConfigDxivpiread-writemandatoryThis is the VPI for the PVC
1.3.6.1.4.1.251.1.1.9.6.1.12ColumnfrbPConfigDxivciread-writemandatoryThis is the VCI for the PVC
1.3.6.1.4.1.251.1.1.9.6.1.13ColumnfrbPConfigDximoderead-writemandatoryThis flag indicates whether the mode is DXI - in that case the value of DLCI is ignored
1.3.6.1.4.1.251.1.1.10Nodedv2VcStatus
1.3.6.1.4.1.251.1.1.10.3TablevcaTablenot-accessiblemandatoryThis table shows detailed status for native ATM slot controller card link A VCs.
1.3.6.1.4.1.251.1.1.10.3.1RowvcaEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.10.3.1.1ColumnvcaVpiread-onlymandatoryVirtual path identifier for the VC.
1.3.6.1.4.1.251.1.1.10.3.1.2ColumnvcaVciread-onlymandatoryVirtual channel identifier for the VC.
1.3.6.1.4.1.251.1.1.10.3.1.3ColumnvcaTxGCellsread-onlymandatoryNumber of transmitted good cells CLP0.
1.3.6.1.4.1.251.1.1.10.3.1.4ColumnvcaTxGCellsClp1read-onlymandatoryNumber of transmitted good cells CLP1.
1.3.6.1.4.1.251.1.1.10.3.1.5ColumnvcaRxGCellsread-onlymandatoryNumber of received good cells.
1.3.6.1.4.1.251.1.1.10.3.1.6ColumnvcaExcessCellsread-onlymandatoryNumber of cells discarded because of bucket overflow.
1.3.6.1.4.1.251.1.1.10.3.1.7ColumnvcaPeakExceedsread-onlymandatoryNumber of cells discarded because of peak cell rate violation.
1.3.6.1.4.1.251.1.1.10.3.1.8ColumnvcaCellHeadread-onlymandatoryThis value is bitwise OR'd with the cell header.
1.3.6.1.4.1.251.1.1.10.3.1.9ColumnvcaCellMaskread-onlymandatoryThis value is bitwise AND'd with the cell header.
1.3.6.1.4.1.251.1.1.10.3.1.10ColumnvcaCellSwitchHeadread-onlymandatoryThis comprises a tag which is added to the cell before putting into the cell switch and a control byte.
1.3.6.1.4.1.251.1.1.10.3.1.11ColumnvcaStartTimeread-onlymandatoryThis is the bucket start time.
1.3.6.1.4.1.251.1.1.10.3.1.12ColumnvcaBucketControlread-onlymandatoryThis is the bucket control register value.
1.3.6.1.4.1.251.1.1.10.3.1.13ColumnvcaBucket0CVread-onlymandatoryThe current value of bucket 0.
1.3.6.1.4.1.251.1.1.10.3.1.14ColumnvcaBucket0Maxread-onlymandatoryThe maximum value of bucket 0.
1.3.6.1.4.1.251.1.1.10.3.1.15ColumnvcaBucket0Incread-onlymandatoryThe bucket 0 increment value.
1.3.6.1.4.1.251.1.1.10.3.1.16ColumnvcaBucket1CVread-onlymandatoryThe current value of bucket 1.
1.3.6.1.4.1.251.1.1.10.3.1.17ColumnvcaBucket1Maxread-onlymandatoryThe maximum value of bucket 1.
1.3.6.1.4.1.251.1.1.10.3.1.18ColumnvcaBucket1Incread-onlymandatoryThe bucket 1 increment value.
1.3.6.1.4.1.251.1.1.10.3.1.19ColumnvcaBucket2CVread-onlymandatoryThe current value of bucket 2.
1.3.6.1.4.1.251.1.1.10.3.1.20ColumnvcaBucket2Maxread-onlymandatoryThe maximum value of bucket 2.
1.3.6.1.4.1.251.1.1.10.3.1.21ColumnvcaBucket2Incread-onlymandatoryThe bucket 2 increment value.
1.3.6.1.4.1.251.1.1.10.3.1.22ColumnvcaBucket3CVread-onlymandatoryThe current value of bucket 3.
1.3.6.1.4.1.251.1.1.10.3.1.23ColumnvcaBucket3Maxread-onlymandatoryThe maximum value of bucket 3.
1.3.6.1.4.1.251.1.1.10.3.1.24ColumnvcaBucket3Incread-onlymandatoryThe bucket 3 increment value.
1.3.6.1.4.1.251.1.1.10.3.1.25ColumnvcaTyperead-onlymandatoryVirtual channel type for the VC.
1.3.6.1.4.1.251.1.1.10.3.1.26ColumnvcaDstSlotread-onlymandatoryslot # this VC is going to
1.3.6.1.4.1.251.1.1.10.3.1.27ColumnvcaDstLinkread-onlymandatorylink # this VC is going to
1.3.6.1.4.1.251.1.1.10.3.1.28ColumnvcaDstVpiread-onlymandatoryVPI this VC is destined for.
1.3.6.1.4.1.251.1.1.10.3.1.29ColumnvcaDstVciread-onlymandatoryVCI for this VC is destined for.
1.3.6.1.4.1.251.1.1.10.3.1.30ColumnvcaInternalVpiread-onlymandatoryInternal VPI
1.3.6.1.4.1.251.1.1.10.3.1.31ColumnvcaInternalVciread-onlymandatoryInternal VCI
1.3.6.1.4.1.251.1.1.10.4TablevcbTablenot-accessiblemandatoryThis table shows detailed status for native ATM slot controller card link B VCs.
1.3.6.1.4.1.251.1.1.10.4.1RowvcbEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.10.4.1.1ColumnvcbVpiread-onlymandatoryVirtual path identifier for the VC.
1.3.6.1.4.1.251.1.1.10.4.1.2ColumnvcbVciread-onlymandatoryVirtual channel identifier for the VC.
1.3.6.1.4.1.251.1.1.10.4.1.3ColumnvcbTxGCellsread-onlymandatoryNumber of transmitted good cells CLP0.
1.3.6.1.4.1.251.1.1.10.4.1.4ColumnvcbTxGCellsClp1read-onlymandatoryNumber of transmitted good cells CLP1.
1.3.6.1.4.1.251.1.1.10.4.1.5ColumnvcbRxGCellsread-onlymandatoryNumber of received good cells.
1.3.6.1.4.1.251.1.1.10.4.1.6ColumnvcbExcessCellsread-onlymandatoryNumber of cells discarded because of bucket overflow.
1.3.6.1.4.1.251.1.1.10.4.1.7ColumnvcbPeakExceedsread-onlymandatoryNumber of cells discarded because of peak cell rate violation.
1.3.6.1.4.1.251.1.1.10.4.1.8ColumnvcbCellHeadread-onlymandatoryThis value is bitwise OR'd with the cell header.
1.3.6.1.4.1.251.1.1.10.4.1.9ColumnvcbCellMaskread-onlymandatoryThis value is bitwise AND'd with the cell header.
1.3.6.1.4.1.251.1.1.10.4.1.10ColumnvcbCellSwitchHeadread-onlymandatoryThis comprises a tag which is added to the cell before putting into the cell switch and a control byte.
1.3.6.1.4.1.251.1.1.10.4.1.11ColumnvcbStartTimeread-onlymandatoryThis is the bucket start time.
1.3.6.1.4.1.251.1.1.10.4.1.12ColumnvcbBucketControlread-onlymandatoryThis is the bucket control register value.
1.3.6.1.4.1.251.1.1.10.4.1.13ColumnvcbBucket0CVread-onlymandatoryThe current value of bucket 0.
1.3.6.1.4.1.251.1.1.10.4.1.14ColumnvcbBucket0Maxread-onlymandatoryThe maximum value of bucket 0.
1.3.6.1.4.1.251.1.1.10.4.1.15ColumnvcbBucket0Incread-onlymandatoryThe bucket 0 increment value.
1.3.6.1.4.1.251.1.1.10.4.1.16ColumnvcbBucket1CVread-onlymandatoryThe current value of bucket 1.
1.3.6.1.4.1.251.1.1.10.4.1.17ColumnvcbBucket1Maxread-onlymandatoryThe maximum value of bucket 1.
1.3.6.1.4.1.251.1.1.10.4.1.18ColumnvcbBucket1Incread-onlymandatoryThe bucket 1 increment value.
1.3.6.1.4.1.251.1.1.10.4.1.19ColumnvcbBucket2CVread-onlymandatoryThe current value of bucket 2.
1.3.6.1.4.1.251.1.1.10.4.1.20ColumnvcbBucket2Maxread-onlymandatoryThe maximum value of bucket 2.
1.3.6.1.4.1.251.1.1.10.4.1.21ColumnvcbBucket2Incread-onlymandatoryThe bucket 2 increment value.
1.3.6.1.4.1.251.1.1.10.4.1.22ColumnvcbBucket3CVread-onlymandatoryThe current value of bucket 3.
1.3.6.1.4.1.251.1.1.10.4.1.23ColumnvcbBucket3Maxread-onlymandatoryThe maximum value of bucket 3.
1.3.6.1.4.1.251.1.1.10.4.1.24ColumnvcbBucket3Incread-onlymandatoryThe bucket 3 increment value.
1.3.6.1.4.1.251.1.1.10.4.1.25ColumnvcbTyperead-onlymandatoryVirtual channel type for the VC.
1.3.6.1.4.1.251.1.1.10.4.1.26ColumnvcbDstSlotread-onlymandatoryslot # this VC is going to
1.3.6.1.4.1.251.1.1.10.4.1.27ColumnvcbDstLinkread-onlymandatorylink # this VC is going to
1.3.6.1.4.1.251.1.1.10.4.1.28ColumnvcbDstVpiread-onlymandatoryVPI this VC is destined for.
1.3.6.1.4.1.251.1.1.10.4.1.29ColumnvcbDstVciread-onlymandatoryVCI for this VC is destined for.
1.3.6.1.4.1.251.1.1.10.4.1.30ColumnvcbInternalVpiread-onlymandatoryInternal VPI
1.3.6.1.4.1.251.1.1.10.4.1.31ColumnvcbInternalVciread-onlymandatoryInternal VCI
1.3.6.1.4.1.251.1.1.10.5TablexpStatTablenot-accessiblemandatoryThis table shows status of the switch fabric interface.
1.3.6.1.4.1.251.1.1.10.5.1RowxpStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.10.5.1.1ColumnxpIFaceread-onlymandatorySwitch fabric interface number.
1.3.6.1.4.1.251.1.1.10.5.1.2ColumnxpRXCellsread-onlymandatorySwitch fabric received cell count.
1.3.6.1.4.1.251.1.1.10.5.1.3ColumnxpTXCellsread-onlymandatorySwitch fabric transmit cell count.
1.3.6.1.4.1.251.1.1.10.5.1.4ColumnxpBadVpiVciread-onlymandatoryNumber of cells with bad VCI/VPI received.
1.3.6.1.4.1.251.1.1.10.5.1.5ColumnxpRxOverflowread-onlymandatoryNumber of receiver overflows.
1.3.6.1.4.1.251.1.1.10.5.1.6ColumnxpTxHighPrOverread-onlymandatoryNumber of transmitted cells with high priority overflow.
1.3.6.1.4.1.251.1.1.10.5.1.7ColumnxpTxLowPrOverread-onlymandatoryNumber of transmitted cells with low priority overflow.
1.3.6.1.4.1.251.1.1.10.5.1.8ColumnxpInputOverflowread-onlymandatoryNumber of M68302 fabric input overflow cells.
1.3.6.1.4.1.251.1.1.10.5.1.9ColumnxpDocErrorsread-onlymandatoryNumber of DOC errors.
1.3.6.1.4.1.251.1.1.10.5.1.10ColumnxpLowPriorityFiforead-onlymandatoryRead transmit low priority FIFO count.
1.3.6.1.4.1.251.1.1.10.5.1.11ColumnxpEgDiscCellsread-onlymandatoryRead transmit discard cell count.
1.3.6.1.4.1.251.1.1.10.5.1.12ColumnxpIgDiscCellsread-onlymandatoryRead receive discard cell count.
1.3.6.1.4.1.251.1.1.11Nodedv2PLPP
1.3.6.1.4.1.251.1.1.11.1TableplppCTablenot-accessiblemandatoryThis table is used to control PLPP configuration.
1.3.6.1.4.1.251.1.1.11.1.1RowplppCEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.1.1.1ColumnplppCLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.11.1.1.2ColumnplppCLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.11.1.1.3ColumnplppCCPLCPModeread-writemandatoryThe PLCP mode for link.
1.3.6.1.4.1.251.1.1.11.1.1.4ColumnplppCDS3Framerread-writemandatorySet to yes(1) to enable the DS3 framer mode for this link.
1.3.6.1.4.1.251.1.1.11.1.1.5ColumnplppCScramblerread-writemandatorySet to no(2) to disable the scrambler mode for this link.
1.3.6.1.4.1.251.1.1.11.1.1.6ColumnplppC0x55read-writemandatoryIf set to no(2) then HCS is not XORed with 0x55
1.3.6.1.4.1.251.1.1.11.1.1.7ColumnplppCCLineread-writemandatoryControl line processing for this link.
1.3.6.1.4.1.251.1.1.11.1.1.8ColumnplppCLoopbackread-writemandatorySet to yes(1) to enable loopback mode for this link.
1.3.6.1.4.1.251.1.1.11.1.1.12ColumnplppCSmdsModeread-writemandatorySet to yes(1) to enable SMDS mode.
1.3.6.1.4.1.251.1.1.11.1.1.13ColumnplppCPloadTypeLabread-writemandatoryPay type label.
1.3.6.1.4.1.251.1.1.11.1.1.14ColumnplppCTxTrlTrcIdLenread-writemandatoryTrail trace length for transmit and expected receive.
1.3.6.1.4.1.251.1.1.11.1.1.15ColumnplppCTxTrcIdread-writemandatoryTransmit trail trace identifier.
1.3.6.1.4.1.251.1.1.11.1.1.16ColumnplppCRxExTrcIdread-writemandatoryReceive expected trail trace identifier.
1.3.6.1.4.1.251.1.1.11.2TableplppSTablenot-accessiblemandatoryThe status table for plpp.
1.3.6.1.4.1.251.1.1.11.2.1RowplppSEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.2.1.1ColumnplppSLinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.11.2.1.2ColumnplppSCLinesread-onlymandatoryThe state of control lines for this link.
1.3.6.1.4.1.251.1.1.11.2.1.3ColumnplppSTXclockread-onlymandatoryThe state of TX clock for this link.
1.3.6.1.4.1.251.1.1.11.2.1.4ColumnplppSRXclockread-onlymandatoryThe state of RX clock for this link.
1.3.6.1.4.1.251.1.1.11.2.1.5ColumnplppSTXCellsread-onlymandatoryThe transmit cells count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.6ColumnplppSRXCellsread-onlymandatoryThe receive cells count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.7ColumnplppSHCSErrsread-onlymandatoryThe header checksum error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.11ColumnplppSFrameErrsread-onlymandatoryThe frame error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.12ColumnplppSBIP8Errsread-onlymandatoryThe BIP-8 error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.13ColumnplppSFEBEErrsread-onlymandatoryThe FEBE error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.14ColumnplppSSPLRStatusread-onlymandatoryThe SPLR Status Register Contents.
1.3.6.1.4.1.251.1.1.11.2.1.15ColumnplppSDs3Lcvsread-onlymandatoryThe DS3 LCV count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.16ColumnplppSDs3FrameErrsread-onlymandatoryThe DS3 frame error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.17ColumnplppSDs3ParityErrsread-onlymandatoryThe DS3 parity error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.18ColumnplppSDs3CbitPrtyErrsread-onlymandatoryThe DS3 control bit parity error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.19ColumnplppSDs3FEBEErrsread-onlymandatoryThe DS3 FEBE error count for this link.
1.3.6.1.4.1.251.1.1.11.2.1.20ColumnplppSDs3RxAISread-onlymandatoryReceive DS3 AIS status.
1.3.6.1.4.1.251.1.1.11.2.1.21ColumnplppSDs3RxRedAlarmread-onlymandatoryReceive DS3 Red Alarm status.
1.3.6.1.4.1.251.1.1.11.2.1.22ColumnplppSDs3RxYellowAlarmread-onlymandatoryReceive DS3 Yellow Alarm status.
1.3.6.1.4.1.251.1.1.11.2.1.23ColumnplppSPLCPRxYellowAlarmread-onlymandatoryReceive PLCP Yellow Alarm status.
1.3.6.1.4.1.251.1.1.11.2.1.24ColumnplppsRxTrIdMisread-onlymandatoryReceive trace id mismatch indication.
1.3.6.1.4.1.251.1.1.11.2.1.25ColumnplppsRxTrIdUnstread-onlymandatoryReceive trace id unstable indication.
1.3.6.1.4.1.251.1.1.11.2.1.26ColumnplppsRxPloadTypeLabMisread-onlymandatoryReceive payload type label mismatch indication.
1.3.6.1.4.1.251.1.1.11.2.1.27ColumnplppsRxPloadTypeLabUnstread-onlymandatoryReceive payload type label unstable indication.
1.3.6.1.4.1.251.1.1.11.2.1.28ColumnplppsRxTrlTrcread-onlymandatoryLast received trail trace message.
1.3.6.1.4.1.251.1.1.11.3TableplppV2CTablenot-accessiblemandatoryThis table is used to control DS3-2C PLPP configuration.
1.3.6.1.4.1.251.1.1.11.3.1RowplppV2CEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.3.1.1ColumnplppV2CLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.11.3.1.2ColumnplppV2CLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.11.3.1.3ColumnplppV2CCPLCPModeread-writemandatorySet to yes(1) to enable the PLCP layer mode for this link.
1.3.6.1.4.1.251.1.1.11.3.1.4ColumnplppV2CDS3Framerread-writemandatorySet to yes(1) to enable the DS3 framer mode for this link.
1.3.6.1.4.1.251.1.1.11.3.1.5ColumnplppV2CScramblerread-writemandatorySet to no(2) to disable the scrambler mode for this link.
1.3.6.1.4.1.251.1.1.11.3.1.6ColumnplppV2C0x55read-writemandatoryIf set to no(2) then HCS is not XORed with 0x55
1.3.6.1.4.1.251.1.1.11.3.1.7ColumnplppV2CLoopbackread-writemandatorySet to yes(1) to enable loopback mode for this link.
1.3.6.1.4.1.251.1.1.11.3.1.8ColumnplppV2CSmdsModeread-writemandatorySet to yes(1) to enable SMDS mode.
1.3.6.1.4.1.251.1.1.11.3.1.9ColumnplppV2CFrmFmtread-writemandatorySet to yes(1) to enable C-bit parity framing format.
1.3.6.1.4.1.251.1.1.11.3.1.10ColumnplppV2CTxAISread-writemandatorySet to yes(1) to enable framer to Txmt AIS.
1.3.6.1.4.1.251.1.1.11.4TableplppV2STablenot-accessiblemandatoryThe status table for DS3-2C plpp.
1.3.6.1.4.1.251.1.1.11.4.1RowplppV2SEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.4.1.1ColumnplppV2SLinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.11.4.1.2ColumnplppV2STXclockread-onlymandatoryThe state of TX clock for this link.
1.3.6.1.4.1.251.1.1.11.4.1.3ColumnplppV2SRXclockread-onlymandatoryThe state of RX clock for this link.
1.3.6.1.4.1.251.1.1.11.4.1.4ColumnplppV2STXCellsread-onlymandatoryThe transmit cells count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.5ColumnplppV2SRXCellsread-onlymandatoryThe receive cells count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.6ColumnplppV2SHCSErrsread-onlymandatoryThe header checksum error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.7ColumnplppV2SFrameErrsread-onlymandatoryThe frame error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.8ColumnplppV2SBIP8Errsread-onlymandatoryThe BIP-8 error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.9ColumnplppV2SFEBEErrsread-onlymandatoryThe FEBE error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.10ColumnplppV2SSPLRStatusread-onlymandatoryyes(1) indicates a PLCP LOF.
1.3.6.1.4.1.251.1.1.11.4.1.11ColumnplppV2SDs3FrmFmtread-onlymandatoryOperate in DS3 C-bit Parity or drop-back to Clear Channel.
1.3.6.1.4.1.251.1.1.11.4.1.12ColumnplppV2SDs3Lcvsread-onlymandatoryThe DS3 LCV count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.13ColumnplppV2SDs3FrameErrsread-onlymandatoryThe DS3 frame error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.14ColumnplppV2SDs3ParityErrsread-onlymandatoryThe DS3 parity error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.15ColumnplppV2SDs3CbitPrtyErrsread-onlymandatoryThe DS3 control bit parity error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.16ColumnplppV2SDs3FEBEErrsread-onlymandatoryThe DS3 FEBE error count for this link.
1.3.6.1.4.1.251.1.1.11.4.1.17ColumnplppV2SDs3RxAISread-onlymandatoryReceive DS3 AIS status.
1.3.6.1.4.1.251.1.1.11.4.1.18ColumnplppV2SDs3RxRedAlarmread-onlymandatoryReceive DS3 Red Alarm status.
1.3.6.1.4.1.251.1.1.11.4.1.19ColumnplppV2SDs3RxYellowAlarmread-onlymandatoryReceive DS3 Yellow Alarm status.
1.3.6.1.4.1.251.1.1.11.4.1.20ColumnplppV2SPLCPRxYellowAlarmread-onlymandatoryReceive PLCP Yellow Alarm status.
1.3.6.1.4.1.251.1.1.11.4.1.21ColumnplppV2SDs3FEACTxmtread-onlymandatoryCode that has been transmitted as a FEAC.
1.3.6.1.4.1.251.1.1.11.4.1.22ColumnplppV2SRxIDLread-onlymandatoryyes(1) indicates an IDLE has been received.
1.3.6.1.4.1.251.1.1.11.4.1.23ColumnplppV2SLOCread-onlymandatoryReceive Loss of cell delineation.
1.3.6.1.4.1.251.1.1.11.4.1.24ColumnplppV2SDs3LPBKread-onlymandatoryif yes(1), the DS3 Framer is in loopback.
1.3.6.1.4.1.251.1.1.11.5TableplppE1CTablenot-accessiblemandatoryThis table to control the E1-2C PLPP configuration.
1.3.6.1.4.1.251.1.1.11.5.1RowplppE1CEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.5.1.1ColumnplppE1CLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.11.5.1.2ColumnplppE1CLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.11.5.1.3ColumnplppE1CScramblerread-writemandatorySet to no(2) to disable the scrambler mode for this link.
1.3.6.1.4.1.251.1.1.11.5.1.4ColumnplppE1C0x55read-writemandatoryIf set to no(2) then HCS is not XORed with 0x55
1.3.6.1.4.1.251.1.1.11.5.1.5ColumnplppE1CSmdsModeread-writemandatorySet to yes(1) to enable SMDS mode.
1.3.6.1.4.1.251.1.1.11.5.1.6ColumnplppE1CLpbkread-writemandatorySet to yes(1) to enable DOC Framer loopback.
1.3.6.1.4.1.251.1.1.11.6TableplppE1STablenot-accessiblemandatoryThe status table for E1-2C plpp.
1.3.6.1.4.1.251.1.1.11.6.1RowplppE1SEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.6.1.1ColumnplppE1SLinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.11.6.1.2ColumnplppE1STXclockread-onlymandatoryThe state of TX clock for this link.
1.3.6.1.4.1.251.1.1.11.6.1.3ColumnplppE1SRXclockread-onlymandatoryThe state of RX clock for this link.
1.3.6.1.4.1.251.1.1.11.6.1.4ColumnplppE1STXCellsread-onlymandatoryThe transmit cells count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.5ColumnplppE1SRXCellsread-onlymandatoryThe receive cells count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.6ColumnplppE1SHCSErrsread-onlymandatoryThe HCS error count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.7ColumnplppE1SCRCErrsread-onlymandatoryThe CRC-4 error count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.8ColumnplppE1SFrameErrsread-onlymandatoryThe frame error count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.9ColumnplppE1SFEBEErrsread-onlymandatoryThe FEBE error count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.10ColumnplppE1SLcvsread-onlymandatoryThe E1 LCV count for this link.
1.3.6.1.4.1.251.1.1.11.6.1.11ColumnplppE1SRxAISread-onlymandatoryReceive E1 AIS status.
1.3.6.1.4.1.251.1.1.11.6.1.12ColumnplppE1SRxOOFread-onlymandatoryReceive E1 OOF status.
1.3.6.1.4.1.251.1.1.11.6.1.13ColumnplppE1SRxLOSread-onlymandatoryReceive E1 LOS status.
1.3.6.1.4.1.251.1.1.11.6.1.14ColumnplppE1SRxLOFread-onlymandatoryReceive E1 LOF status.
1.3.6.1.4.1.251.1.1.11.6.1.15ColumnplppE1SFerfread-onlymandatoryReceiving a Far-End Receive Failure if yes.
1.3.6.1.4.1.251.1.1.11.7TableplppE3CTablenot-accessiblemandatoryThis table is used to control the E3-2C PLPP configuration.
1.3.6.1.4.1.251.1.1.11.7.1RowplppE3CEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.7.1.1ColumnplppE3CLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.11.7.1.2ColumnplppE3CLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.11.7.1.3ColumnplppE3CFramerread-writemandatoryThe E3 framer mode for the link.
1.3.6.1.4.1.251.1.1.11.7.1.4ColumnplppE3CPLCPModeread-writemandatoryThe PLCP mode for the link.
1.3.6.1.4.1.251.1.1.11.7.1.5ColumnplppE3CScramblerread-writemandatorySet to no(2) to disable the scrambler mode for this link.
1.3.6.1.4.1.251.1.1.11.7.1.6ColumnplppE3C0x55read-writemandatoryIf set to no(2) then HCS is not XORed with 0x55
1.3.6.1.4.1.251.1.1.11.7.1.7ColumnplppE3CLoopbackread-writemandatorySet to yes(1) to enable loopback mode for this link.
1.3.6.1.4.1.251.1.1.11.7.1.8ColumnplppE3CSmdsModeread-writemandatorySet to yes(1) to enable SMDS mode.
1.3.6.1.4.1.251.1.1.11.7.1.9ColumnplppE3CTxmtTimMkread-writemandatorySet to yes(1) if traceable to primary ref clk.
1.3.6.1.4.1.251.1.1.11.7.1.10ColumnplppE3CPloadTypeLabread-writemandatoryPayload type label.
1.3.6.1.4.1.251.1.1.11.7.1.11ColumnplppE3CTxTrlTrcIdLenread-writemandatoryTrail trace length for transmit and expected receive.
1.3.6.1.4.1.251.1.1.11.7.1.12ColumnplppE3CTxTrcIdUHread-writemandatoryTransmit trail trace ID upper half.
1.3.6.1.4.1.251.1.1.11.7.1.13ColumnplppE3CTxTrcIdLHread-writemandatoryTransmit trail trace ID lower half.
1.3.6.1.4.1.251.1.1.11.7.1.14ColumnplppE3CRxExTrcIdUHread-writemandatoryReceive expected trail trace ID upper half.
1.3.6.1.4.1.251.1.1.11.7.1.15ColumnplppE3CRxExTrcIdLHread-writemandatoryReceive expected trail trace ID lower half.
1.3.6.1.4.1.251.1.1.11.8TableplppE3STablenot-accessiblemandatoryThe E3-2C status table for plpp.
1.3.6.1.4.1.251.1.1.11.8.1RowplppE3SEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.11.8.1.1ColumnplppE3SLinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.11.8.1.2ColumnplppE3STXclockread-onlymandatoryThe state of TX clock for this link.
1.3.6.1.4.1.251.1.1.11.8.1.3ColumnplppE3SRXclockread-onlymandatoryThe state of RX clock for this link.
1.3.6.1.4.1.251.1.1.11.8.1.4ColumnplppE3STXCellsread-onlymandatoryThe transmit cells count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.5ColumnplppE3SRXCellsread-onlymandatoryThe receive cells count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.6ColumnplppE3SHCSErrsread-onlymandatoryThe header checksum error count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.7ColumnplppE3SE3FrameErrsread-onlymandatoryThe E3 frame error count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.8ColumnplppE3SPLCPFrameErrsread-onlymandatoryThe PLCP frame error count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.9ColumnplppE3SBIP8Errsread-onlymandatoryThe BIP-8 error count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.10ColumnplppE3SFEBEErrsread-onlymandatoryThe FEBE error count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.11ColumnplppE3SLcvsread-onlymandatoryThe E3 LCV count for this link.
1.3.6.1.4.1.251.1.1.11.8.1.12ColumnplppE3SLcdread-onlymandatoryReceive Loss of cell delineation.
1.3.6.1.4.1.251.1.1.11.8.1.13ColumnplppE3SRxTrlTrcread-onlymandatoryLast received trail trace message.
1.3.6.1.4.1.251.1.1.11.8.1.14ColumnplppE3SRxAISread-onlymandatoryReceive E3 AIS status.
1.3.6.1.4.1.251.1.1.11.8.1.15ColumnplppE3SRxOOFread-onlymandatoryReceive E3 OOF status.
1.3.6.1.4.1.251.1.1.11.8.1.16ColumnplppE3SRxLOSread-onlymandatoryReceive E3 LOS status.
1.3.6.1.4.1.251.1.1.11.8.1.17ColumnplppE3SRxLOFread-onlymandatoryReceive E3 LOF status.
1.3.6.1.4.1.251.1.1.11.8.1.18ColumnplppE3SRxFERFread-onlymandatoryReceive E3 FERF status.
1.3.6.1.4.1.251.1.1.11.8.1.19ColumnplppE3SPLCPRxLofread-onlymandatoryThe PLCP Rx LOF for this link.
1.3.6.1.4.1.251.1.1.11.8.1.20ColumnplppE3SPLCPRxYellowAlarmread-onlymandatoryReceive PLCP Yellow Alarm status.
1.3.6.1.4.1.251.1.1.11.8.1.21ColumnplppE3SRxTrIdMisread-onlymandatoryReceive trace id mismatch indication.
1.3.6.1.4.1.251.1.1.11.8.1.22ColumnplppE3SRxTrIdUnstread-onlymandatoryReceive trace id unstable indication.
1.3.6.1.4.1.251.1.1.11.8.1.23ColumnplppE3SRxPloadTypeLabMisread-onlymandatoryReceive payload type label mismatch indication.
1.3.6.1.4.1.251.1.1.11.8.1.24ColumnplppE3SRxPloadTypeLabUnstread-onlymandatoryReceive payload type label unstable indication.
1.3.6.1.4.1.251.1.1.12Nodedv2LocalFibre
1.3.6.1.4.1.251.1.1.12.1TablelFibreConfTablenot-accessiblemandatoryThis table contains configuration information for the LFDOC.
1.3.6.1.4.1.251.1.1.12.1.1RowlFibreConfEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.12.1.1.1ColumnlFibreConfLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.12.1.1.2ColumnlFibreConfLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.12.1.1.3ColumnlFibreConfCLineread-writemandatorySet to ignored(2) to stop control line processing for this link.
1.3.6.1.4.1.251.1.1.12.1.1.4ColumnlFibreConfLoopbackread-writemandatorySet to yes(1) to enable loopback mode for this link.
1.3.6.1.4.1.251.1.1.12.2TablelFibreStatTablenot-accessiblemandatoryThis table contains status information for the LFDOC
1.3.6.1.4.1.251.1.1.12.2.1RowlFibreStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.12.2.1.1ColumnlFibreStatLinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.12.2.1.2ColumnlFibreStatCLinesread-onlymandatoryThe state of control lines for this link.
1.3.6.1.4.1.251.1.1.12.2.1.3ColumnlFibreStatHCSErrsread-onlymandatoryThe header checksum error count for this link.
1.3.6.1.4.1.251.1.1.13Nodedv2DS
1.3.6.1.4.1.251.1.1.13.1Tableds1Tablenot-accessiblemandatoryds1 Status Table
1.3.6.1.4.1.251.1.1.13.1.1Rowds1Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.1.1.1Columnds1LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.1.1.2Columnds1LineLengthread-writemandatoryLength of the line connected to the physical interface.
1.3.6.1.4.1.251.1.1.13.1.1.3Columnds1Framingread-writemandatoryT1 Framing type.
1.3.6.1.4.1.251.1.1.13.1.1.4Columnds1Codingread-writemandatoryThe line code of incoming DS1 signal. ami(2) selects AMI line code.
1.3.6.1.4.1.251.1.1.13.1.1.5Columnds1Trread-writemandatorySet to yes(1) to enable transmit loop-back.
1.3.6.1.4.1.251.1.1.13.1.1.6Columnds1Rtread-writemandatorySet to yes(1) to enable receive loop-back.
1.3.6.1.4.1.251.1.1.13.1.1.7Columnds1LOSDefectread-onlymandatoryLoss of Signal Defect
1.3.6.1.4.1.251.1.1.13.1.1.8Columnds1AISDefectread-onlymandatoryAIS Defect
1.3.6.1.4.1.251.1.1.13.1.1.9Columnds1OOFDefectread-onlymandatoryOOF Defect
1.3.6.1.4.1.251.1.1.13.1.1.10Columnds1YellowDefectread-onlymandatoryYellow Defect
1.3.6.1.4.1.251.1.1.13.1.1.11Columnds1LOSAlarmread-onlymandatoryLoss Of Signal alarm
1.3.6.1.4.1.251.1.1.13.1.1.12Columnds1AISAlarmread-onlymandatoryAIS alarm
1.3.6.1.4.1.251.1.1.13.1.1.13Columnds1LOFAlarmread-onlymandatoryLoss Of Frame alarm
1.3.6.1.4.1.251.1.1.13.1.1.14Columnds1YellowAlarmread-onlymandatoryYellow alarm
1.3.6.1.4.1.251.1.1.13.1.1.15Columnds1PdvCountread-onlymandatoryNumber of pulse density violations detected.
1.3.6.1.4.1.251.1.1.13.1.1.16Columnds1Z16Countread-onlymandatoryNumber of 16 consecutive zeroes detected.
1.3.6.1.4.1.251.1.1.13.1.1.17Columnds1LcvCountread-onlymandatoryNumber of line code violations detected.
1.3.6.1.4.1.251.1.1.13.1.1.18Columnds1BeeCountread-onlymandatoryNumber of block error events detected.
1.3.6.1.4.1.251.1.1.13.1.1.19Columnds1FerCountread-onlymandatoryNumber of framing bit error events detected.
1.3.6.1.4.1.251.1.1.13.1.1.20Columnds1OofCountread-onlymandatoryNumber of out of frame events detected.
1.3.6.1.4.1.251.1.1.13.1.1.21Columnds1ClrStatsread-writemandatoryClear counters
1.3.6.1.4.1.251.1.1.13.1.1.22Columnds1Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.1.1.23Columnds1LineESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.13.1.1.24Columnds1LineSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.13.1.1.25Columnds1ESread-onlymandatoryErrored Seconds
1.3.6.1.4.1.251.1.1.13.1.1.26Columnds1SESread-onlymandatorySeverely Errored Seconds
1.3.6.1.4.1.251.1.1.13.1.1.27Columnds1AISSread-onlymandatoryAIS Seconds
1.3.6.1.4.1.251.1.1.13.1.1.28Columnds1UASread-onlymandatoryUnavailable Seconds
1.3.6.1.4.1.251.1.1.13.1.1.29Columnds1TxClkSelread-writemandatoryTransmit clock select.
1.3.6.1.4.1.251.1.1.13.1.1.30Columnds1ExBERDefectread-onlymandatoryExcessive Bit Error Rate Defect
1.3.6.1.4.1.251.1.1.13.1.1.31Columnds1ExBERAlarmread-onlymandatoryExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.13.2Tableds3Tablenot-accessiblemandatoryds3 Status Table
1.3.6.1.4.1.251.1.1.13.2.1Rowds3Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.2.1.1Columnds3LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.2.1.2Columnds3Lbread-onlymandatoryLoop-back mode active.
1.3.6.1.4.1.251.1.1.13.2.1.3Columnds3Errread-onlymandatoryAIS or BPV detected.
1.3.6.1.4.1.251.1.1.13.2.1.4Columnds3RXLosread-onlymandatoryReceive loss of signal.
1.3.6.1.4.1.251.1.1.13.2.1.5Columnds3TXLocread-onlymandatoryTransmit loss of clock.
1.3.6.1.4.1.251.1.1.13.2.1.6Columnds3RXErrread-onlymandatoryReceive error detected.
1.3.6.1.4.1.251.1.1.13.2.1.7Columnds3RXAisread-writemandatorySet to yes(1) to generate a receive AIS alarm.
1.3.6.1.4.1.251.1.1.13.2.1.8Columnds3TXAisread-writemandatorySet to yes(1) to transmit an AIS alarm.
1.3.6.1.4.1.251.1.1.13.2.1.9Columnds3TXLevread-writemandatoryTransmit level.
1.3.6.1.4.1.251.1.1.13.2.1.10Columnds3Trread-writemandatoryTransmit loop-back.
1.3.6.1.4.1.251.1.1.13.2.1.11Columnds3Rtread-writemandatorySet to yes(1) to enable receive loop-back.
1.3.6.1.4.1.251.1.1.13.2.1.12Columnds3Equalread-writemandatoryEqualisation type.
1.3.6.1.4.1.251.1.1.13.2.1.13Columnds3LOSAlarmread-onlymandatoryLoss Of Signal Integrated Alarm
1.3.6.1.4.1.251.1.1.13.2.1.14Columnds3Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.5Tablee1Tablenot-accessiblemandatoryE1-2C Config/Status Table
1.3.6.1.4.1.251.1.1.13.5.1Rowe1Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.5.1.1Columne1LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.5.1.2Columne1LimTyperead-onlymandatoryLIM I.D. type
1.3.6.1.4.1.251.1.1.13.5.1.3Columne1Lbread-writemandatoryLoopback Selection
1.3.6.1.4.1.251.1.1.13.5.1.4Columne1FRMRModeread-writemandatorye1 Framing options.
1.3.6.1.4.1.251.1.1.13.5.1.5Columne1TxClkSelread-writemandatoryTransmit clock select.
1.3.6.1.4.1.251.1.1.13.5.1.6Columne1TS16PayLdread-writemandatoryEmploy TimeSlot 16 for customer data.
1.3.6.1.4.1.251.1.1.13.5.1.7Columne1TxAISread-writemandatoryTransmit the AIS State.
1.3.6.1.4.1.251.1.1.13.5.1.8Columne1GappedClkread-writemandatorySelect 1,(yes) for Circuit-emulation.
1.3.6.1.4.1.251.1.1.13.5.1.9Columne1IntrfTyperead-writemandatoryE1 Framing options.
1.3.6.1.4.1.251.1.1.13.5.1.10Columne1ClrStatsread-writemandatoryClear Counters
1.3.6.1.4.1.251.1.1.13.5.1.11Columne1Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.5.1.12Columnse1SA4read-writemandatoryNat'l bit Sa4
1.3.6.1.4.1.251.1.1.13.5.1.13Columnse1SA5read-writemandatoryNat'l bit Sa5
1.3.6.1.4.1.251.1.1.13.5.1.14Columnse1SA6read-writemandatoryNat'l bit Sa6
1.3.6.1.4.1.251.1.1.13.5.1.15Columnse1SA7read-writemandatoryNat'l bit Sa7
1.3.6.1.4.1.251.1.1.13.5.1.16Columnse1SA8read-writemandatoryNat'l bit Sa8
1.3.6.1.4.1.251.1.1.13.5.1.17Columnse1SI0read-writemandatoryInt'l bit Si0
1.3.6.1.4.1.251.1.1.13.5.1.18Columnse1SI1read-writemandatoryNat'l bit Si1
1.3.6.1.4.1.251.1.1.13.5.1.22Columne1LOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.5.1.23Columne1OOFDefectread-onlymandatoryReceive Out Of Frame
1.3.6.1.4.1.251.1.1.13.5.1.24Columne1AISDefectread-onlymandatoryReceive AIS Defect
1.3.6.1.4.1.251.1.1.13.5.1.25Columne1FerfDefectread-onlymandatoryReceive Yellow Defect
1.3.6.1.4.1.251.1.1.13.5.1.26Columne1ExBERDefectread-onlymandatoryExcessive Bit Error Rate Defect
1.3.6.1.4.1.251.1.1.13.5.1.37Columne1LOSAlarmread-onlymandatoryLoss Of Signal Integrated Alarm
1.3.6.1.4.1.251.1.1.13.5.1.38Columne1LOFAlarmread-onlymandatoryLoss Of Frame Integrated Alarm
1.3.6.1.4.1.251.1.1.13.5.1.39Columne1AISAlarmread-onlymandatoryAIS Integrated Alarm
1.3.6.1.4.1.251.1.1.13.5.1.40Columne1FerfAlarmread-onlymandatoryYellow Integrated Alarm
1.3.6.1.4.1.251.1.1.13.5.1.41Columne1ExBERAlarmread-onlymandatoryExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.13.5.1.52Columne1SCRCErrsread-onlymandatoryThe CRC-4 error count for this link.
1.3.6.1.4.1.251.1.1.13.5.1.53Columne1SFrameErrsread-onlymandatoryThe frame error count for this link.
1.3.6.1.4.1.251.1.1.13.5.1.54Columne1SFEBEErrsread-onlymandatoryThe FEBE error count for this link.
1.3.6.1.4.1.251.1.1.13.5.1.55Columne1SLcvsread-onlymandatoryThe E1 LCV count for this link.
1.3.6.1.4.1.251.1.1.13.5.1.66Columne1LineESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.13.5.1.67Columne1LineSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.13.5.1.68Columne1ESread-onlymandatoryErrored Seconds
1.3.6.1.4.1.251.1.1.13.5.1.69Columne1SESread-onlymandatorySeverely Errored Seconds
1.3.6.1.4.1.251.1.1.13.5.1.70Columne1AISSread-onlymandatoryAIS Seconds
1.3.6.1.4.1.251.1.1.13.5.1.71Columne1UASread-onlymandatoryUnavailable Seconds
1.3.6.1.4.1.251.1.1.13.7TablesoTablenot-accessiblemandatorySOLIM/DELIM Status Table
1.3.6.1.4.1.251.1.1.13.7.1RowsoEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.7.1.1ColumnsoLinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.7.1.2ColumnsoLimTyperead-onlymandatorySolim version
1.3.6.1.4.1.251.1.1.13.7.1.3ColumnsoTimingRefread-writemandatoryLocal timing reference
1.3.6.1.4.1.251.1.1.13.7.1.4ColumnsoTxEn0read-writemandatoryLink 0 Tx Enable (v2 and above)
1.3.6.1.4.1.251.1.1.13.7.1.5ColumnsoTxEn1read-writemandatoryLink 1 Tx Enable (v2 and above)
1.3.6.1.4.1.251.1.1.13.7.1.6ColumnsoLimDescread-writemandatoryLIM Description
1.3.6.1.4.1.251.1.1.13.7.1.7ColumnsoReconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.9Tableds1V2Tablenot-accessiblemandatoryds1 V2 Status Table
1.3.6.1.4.1.251.1.1.13.9.1Rowds1V2Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.9.1.1Columnds1V2LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.9.1.2Columnds1V2LimTyperead-onlymandatoryLIM I.D. type
1.3.6.1.4.1.251.1.1.13.9.1.3Columnds1V2TxLineLnread-writemandatorySelect txmt line length.
1.3.6.1.4.1.251.1.1.13.9.1.4Columnds1V2FRMRModeread-writemandatoryds1V2 Framing options.
1.3.6.1.4.1.251.1.1.13.9.1.5Columnds1V2Codingread-writemandatoryIf Line Coding is yes(1), AMI is selected
1.3.6.1.4.1.251.1.1.13.9.1.6Columnds1V2Lbread-writemandatoryLoopback Selection
1.3.6.1.4.1.251.1.1.13.9.1.7Columnds1V2TxAISread-writemandatoryTransmit the AIS State.
1.3.6.1.4.1.251.1.1.13.9.1.8Columnds1V2GappedClkread-writemandatorySelect 1,(yes) for Circuit-emulation.
1.3.6.1.4.1.251.1.1.13.9.1.9Columnds1V2TxClkSelread-writemandatoryTransmit clock select.
1.3.6.1.4.1.251.1.1.13.9.1.10Columnds1V2ClrStatsread-writemandatoryClear Counters
1.3.6.1.4.1.251.1.1.13.9.1.11Columnds1V2Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.9.1.22Columnds1V2LOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.9.1.23Columnds1V2OOFDefectread-onlymandatoryReceive Out Of Frame
1.3.6.1.4.1.251.1.1.13.9.1.24Columnds1V2AISDefectread-onlymandatoryReceive AIS Defect
1.3.6.1.4.1.251.1.1.13.9.1.25Columnds1V2FerfDefectread-onlymandatoryReceive FERF(Yellow) Defect
1.3.6.1.4.1.251.1.1.13.9.1.26Columnds1V2BERDefectread-onlymandatoryExcessive Bit Error Rate Defect
1.3.6.1.4.1.251.1.1.13.9.1.37Columnds1V2LOSAlarmread-onlymandatoryLoss Of Signal Integrated Alarm
1.3.6.1.4.1.251.1.1.13.9.1.38Columnds1V2LOFAlarmread-onlymandatoryLoss Of Frame Integrated Alarm
1.3.6.1.4.1.251.1.1.13.9.1.39Columnds1V2AISAlarmread-onlymandatoryAIS Integrated Alarm
1.3.6.1.4.1.251.1.1.13.9.1.40Columnds1V2FerfAlarmread-onlymandatoryYellow Integrated Alarm
1.3.6.1.4.1.251.1.1.13.9.1.41Columnds1V2BERAlarmread-onlymandatoryExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.13.9.1.52Columnds1V2FerCountread-onlymandatoryThe framing bit error count for this link.
1.3.6.1.4.1.251.1.1.13.9.1.53Columnds1V2BeeCountread-onlymandatoryThe bit error count for this link.
1.3.6.1.4.1.251.1.1.13.9.1.54Columnds1V2OCfCountread-onlymandatoryThe Out-of-frame or Change of Frame alignment error count for this link.
1.3.6.1.4.1.251.1.1.13.9.1.55Columnds1V2LcvCountread-onlymandatoryThe DS1 Line code violations count for this link.
1.3.6.1.4.1.251.1.1.13.9.1.66Columnds1V2LineESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.13.9.1.67Columnds1V2LineSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.13.9.1.68Columnds1V2ESread-onlymandatoryErrored Seconds
1.3.6.1.4.1.251.1.1.13.9.1.69Columnds1V2SESread-onlymandatorySeverely Errored Seconds
1.3.6.1.4.1.251.1.1.13.9.1.70Columnds1V2AISSread-onlymandatoryAIS Seconds
1.3.6.1.4.1.251.1.1.13.9.1.71Columnds1V2UASread-onlymandatoryUnavailable Seconds
1.3.6.1.4.1.251.1.1.13.9.1.72Columnds1V2ExBERread-onlymandatoryExcessive Bit Error Rate
1.3.6.1.4.1.251.1.1.13.10ScalardlimLpbkTimeoutread-writemandatoryThis parameter is used to set the dlim loopback timeout in minutes.
1.3.6.1.4.1.251.1.1.13.11Tableds3V2Tablenot-accessiblemandatoryds3-2C Config/Status Table
1.3.6.1.4.1.251.1.1.13.11.1Rowds3V2Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.11.1.1Columnds3V2LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.11.1.2Columnds3V2Lbread-writemandatoryLoopback Active
1.3.6.1.4.1.251.1.1.13.11.1.3Columnds3V2LimTyperead-onlymandatoryLIM I.D. type
1.3.6.1.4.1.251.1.1.13.11.1.4Columnds3V2LimOKread-onlymandatoryLIM OK.
1.3.6.1.4.1.251.1.1.13.11.1.5Columnds3V2TxLBOread-writemandatoryTransmit line build-out,(1)for short cables.
1.3.6.1.4.1.251.1.1.13.11.1.6Columnds3V2TxClkSelread-writemandatoryTransmit clock select.
1.3.6.1.4.1.251.1.1.13.11.1.8Columnds3V2LOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.11.1.9Columnds3V2LOSAlarmread-onlymandatoryLoss Of Signal Alarm
1.3.6.1.4.1.251.1.1.13.11.1.10Columnds3V2Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.12Tablee3Tablenot-accessiblemandatoryE3-2C Config/Status Table
1.3.6.1.4.1.251.1.1.13.12.1Rowe3Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.12.1.1Columne3LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.12.1.2Columne3LimTyperead-onlymandatoryLIM I.D. type
1.3.6.1.4.1.251.1.1.13.12.1.3Columne3LimOKread-onlymandatoryLIM OK.
1.3.6.1.4.1.251.1.1.13.12.1.4Columne3EQSelectread-writemandatoryRx Line Equalization select.
1.3.6.1.4.1.251.1.1.13.12.1.6Columne3Loopbackread-writemandatoryLoopback LIU.
1.3.6.1.4.1.251.1.1.13.12.1.7Columne3TxAISread-writemandatoryTransmit AIS.
1.3.6.1.4.1.251.1.1.13.12.1.8Columne3TxClkSelread-writemandatoryTransmit clock select.
1.3.6.1.4.1.251.1.1.13.12.1.9Columne3LOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.12.1.10Columne3LOSAlarmread-onlymandatoryLoss Of Signal Alarm
1.3.6.1.4.1.251.1.1.13.12.1.11Columne3Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.13TablehssiTablenot-accessiblemandatoryhssi Status Table
1.3.6.1.4.1.251.1.1.13.13.1RowhssiEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.13.1.1ColumnhssiLinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.13.1.2ColumnhssiLocalLoopbackread-writemandatoryLocal Loopback.
1.3.6.1.4.1.251.1.1.13.13.1.3ColumnhssiRemoteLoopbackread-writemandatoryRemote Loopback.
1.3.6.1.4.1.251.1.1.13.13.1.4ColumnhssiReconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.13.1.15ColumnhssiTyperead-writemandatoryType of link.
1.3.6.1.4.1.251.1.1.13.13.1.16ColumnhssiLimTyperead-onlymandatoryLIM Version
1.3.6.1.4.1.251.1.1.13.13.1.17ColumnhssiClockSrcread-writemandatorySource of clock. Note that for a DCE, from-DCE(4) should not be selected.
1.3.6.1.4.1.251.1.1.13.13.1.18ColumnhssiCtrTestModeread-onlymandatoryTest Mode.
1.3.6.1.4.1.251.1.1.13.13.1.19ColumnhssiLinkReadyread-onlymandatorySet to yes(1) if link is ready.
1.3.6.1.4.1.251.1.1.13.13.1.20ColumnhssiRemoteReadyread-onlymandatorySet to yes(1) if remote link is ready.
1.3.6.1.4.1.251.1.1.13.13.1.25ColumnhssiLOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.13.1.30ColumnhssiLOSAlarmread-onlymandatoryLoss Of Signal Alarm
1.3.6.1.4.1.251.1.1.13.14Tablej2Tablenot-accessiblemandatoryJ2 Config/Status Table
1.3.6.1.4.1.251.1.1.13.14.1Rowj2Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.14.1.1Columnj2LinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.14.1.3Columnj2FirmwareRevread-onlymandatoryFirmware Revision
1.3.6.1.4.1.251.1.1.13.14.1.4Columnj2TxEqread-writemandatorySelect equalizer setting
1.3.6.1.4.1.251.1.1.13.14.1.6Columnj2Lbread-writemandatoryLoopback Selection
1.3.6.1.4.1.251.1.1.13.14.1.7Columnj2TxAISread-writemandatoryTransmit the AIS State.
1.3.6.1.4.1.251.1.1.13.14.1.9Columnj2TxClkSelread-writemandatoryTransmit clock select.
1.3.6.1.4.1.251.1.1.13.14.1.10Columnj2ClrStatsread-writemandatoryClear Counters
1.3.6.1.4.1.251.1.1.13.14.1.11Columnj2Reconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.14.1.12Columnj2TS97TS98read-writemandatorySet the value (in hex) of the bytes to be transmitted in time slots 97 and 98 of the J2 frame.
1.3.6.1.4.1.251.1.1.13.14.1.20Columnj2QualClockread-onlymandatoryQuality of Clock Selection
1.3.6.1.4.1.251.1.1.13.14.1.22Columnj2LOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.14.1.23Columnj2OOFDefectread-onlymandatoryReceive Out Of Frame
1.3.6.1.4.1.251.1.1.13.14.1.24Columnj2AISDefectread-onlymandatoryReceive AIS Defect
1.3.6.1.4.1.251.1.1.13.14.1.26Columnj2RAlmDefectread-onlymandatoryRemote Alarm Defect
1.3.6.1.4.1.251.1.1.13.14.1.37Columnj2LOSAlarmread-onlymandatoryLoss Of Signal Integrated Alarm
1.3.6.1.4.1.251.1.1.13.14.1.38Columnj2LOFAlarmread-onlymandatoryLoss Of Frame Integrated Alarm
1.3.6.1.4.1.251.1.1.13.14.1.39Columnj2AISAlarmread-onlymandatoryAIS Integrated Alarm
1.3.6.1.4.1.251.1.1.13.14.1.41Columnj2RAlmAlarmread-onlymandatoryRemote Alarm Condition
1.3.6.1.4.1.251.1.1.13.14.1.52Columnj2FerCountread-onlymandatoryThe framing bit error count for this link.
1.3.6.1.4.1.251.1.1.13.14.1.53Columnj2RAlmCountread-onlymandatoryThe Remote Alarm error count for this link.
1.3.6.1.4.1.251.1.1.13.14.1.55Columnj2LcvCountread-onlymandatoryThe J2 Line code violations count for this link.
1.3.6.1.4.1.251.1.1.13.14.1.56Columnj2CrcCountread-onlymandatoryNumber of J2 muliframes received with CRC errors
1.3.6.1.4.1.251.1.1.13.14.1.66Columnj2LineESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.13.14.1.67Columnj2LineSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.13.14.1.68Columnj2ESread-onlymandatoryErrored Seconds
1.3.6.1.4.1.251.1.1.13.14.1.69Columnj2SESread-onlymandatorySeverely Errored Seconds
1.3.6.1.4.1.251.1.1.13.14.1.70Columnj2AISSread-onlymandatoryAIS Seconds
1.3.6.1.4.1.251.1.1.13.14.1.71Columnj2UASread-onlymandatoryUnavailable Seconds
1.3.6.1.4.1.251.1.1.13.15TablescfTablenot-accessiblemandatorySCF Config/Status Table
1.3.6.1.4.1.251.1.1.13.15.1RowscfEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.13.15.1.1ColumnscfLinkNoread-onlymandatoryLink number - this is the instance.
1.3.6.1.4.1.251.1.1.13.15.1.2ColumnscfLimTyperead-onlymandatoryLIM I.D. type
1.3.6.1.4.1.251.1.1.13.15.1.3ColumnscfFirmwareRevread-onlymandatoryFirmware Revision
1.3.6.1.4.1.251.1.1.13.15.1.4ColumnscfQualClockread-onlymandatoryQuality of Clock Selection
1.3.6.1.4.1.251.1.1.13.15.1.5ColumnscfContrread-writemandatoryController Selection
1.3.6.1.4.1.251.1.1.13.15.1.6ColumnscfDCEDTEread-writemandatoryDCE or DTE Selection
1.3.6.1.4.1.251.1.1.13.15.1.7ColumnscfLbread-writemandatoryLoopback Selection
1.3.6.1.4.1.251.1.1.13.15.1.8ColumnscfLineTimingread-writemandatoryReceive Line Timing Selection
1.3.6.1.4.1.251.1.1.13.15.1.9ColumnscfDataRateread-writemandatoryData Rate Selection in K Bit/Sec
1.3.6.1.4.1.251.1.1.13.15.1.10ColumnscfClkSelread-writemandatoryClock select
1.3.6.1.4.1.251.1.1.13.15.1.11ColumnscfInterfaceTyperead-writemandatoryInterface type selection
1.3.6.1.4.1.251.1.1.13.15.1.12ColumnscfReconfigread-writemandatoryReconfigure Link
1.3.6.1.4.1.251.1.1.13.15.1.13ColumnscfLOSDefectread-onlymandatoryLoss Of Signal Defect
1.3.6.1.4.1.251.1.1.13.15.1.14ColumnscfLOSAlarmread-onlymandatoryLoss Of Signal Integrated Alarm
1.3.6.1.4.1.251.1.1.14Nodedv2Billing
1.3.6.1.4.1.251.1.1.14.1ScalarbillAvailableread-onlymandatoryNumber of billing records available.
1.3.6.1.4.1.251.1.1.14.3TablebillingTablenot-accessiblemandatoryThis table is used to contain billing records.
1.3.6.1.4.1.251.1.1.14.3.1RowbillingEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.14.3.1.1ColumnbillSeqread-onlymandatorybilling record sequence number.
1.3.6.1.4.1.251.1.1.14.3.1.2ColumnbillSvpiread-onlymandatorySource Virtual Path Identifier for VC.
1.3.6.1.4.1.251.1.1.14.3.1.3ColumnbillSvciread-onlymandatorySource Virtual Circuit Identifier for VC.
1.3.6.1.4.1.251.1.1.14.3.1.4ColumnbillDvpiread-onlymandatoryDestination Virtual Path Identifier for VC.
1.3.6.1.4.1.251.1.1.14.3.1.5ColumnbillDvciread-onlymandatoryDestination Virtual Circuit Identifier for VC.
1.3.6.1.4.1.251.1.1.14.3.1.6ColumnbillSslotread-onlymandatorySource slot for VC.
1.3.6.1.4.1.251.1.1.14.3.1.7ColumnbillSlinkread-onlymandatorySource link for VC.
1.3.6.1.4.1.251.1.1.14.3.1.8ColumnbillDslotread-onlymandatoryDestination slot for VC.
1.3.6.1.4.1.251.1.1.14.3.1.9ColumnbillDlinkread-onlymandatoryDestination link for VC.
1.3.6.1.4.1.251.1.1.14.3.1.10ColumnbillCalledread-onlymandatoryCalled or Destination E.164 address.
1.3.6.1.4.1.251.1.1.14.3.1.11ColumnbillCalledSubread-onlymandatoryCalled or Destination E.164 sub-address.
1.3.6.1.4.1.251.1.1.14.3.1.12ColumnbillCallingread-onlymandatoryCalling or Originating E.164 address.
1.3.6.1.4.1.251.1.1.14.3.1.13ColumnbillCallingSubread-onlymandatoryCalling or Originating E.164 sub-address.
1.3.6.1.4.1.251.1.1.14.3.1.14ColumnbillCellInCread-onlymandatoryCell in overflows count.
1.3.6.1.4.1.251.1.1.14.3.1.15ColumnbillCellInread-onlymandatoryCell in count.
1.3.6.1.4.1.251.1.1.14.3.1.16ColumnbillFrameInread-onlymandatoryFrame in count.
1.3.6.1.4.1.251.1.1.14.3.1.17ColumnbillByteInCread-onlymandatoryByte in overflows count.
1.3.6.1.4.1.251.1.1.14.3.1.18ColumnbillByteInread-onlymandatoryByte in count.
1.3.6.1.4.1.251.1.1.14.3.1.19ColumnbillCellOutCread-onlymandatoryCell out overflows count.
1.3.6.1.4.1.251.1.1.14.3.1.20ColumnbillCellOutread-onlymandatoryCell out count.
1.3.6.1.4.1.251.1.1.14.3.1.21ColumnbillFrameOutread-onlymandatoryFrame out count.
1.3.6.1.4.1.251.1.1.14.3.1.22ColumnbillByteOutCread-onlymandatoryByte out overflows count.
1.3.6.1.4.1.251.1.1.14.3.1.23ColumnbillByteOutread-onlymandatoryByte out count.
1.3.6.1.4.1.251.1.1.14.3.1.25ColumnbillCauseread-onlymandatoryClear cause code.
1.3.6.1.4.1.251.1.1.14.3.1.28ColumnbillValidread-writemandatoryDeletes billing record Entry by setting to invalid(2).
1.3.6.1.4.1.251.1.1.14.3.1.29ColumnbillCLP1OutCread-onlymandatoryCLP1 out overflows count.
1.3.6.1.4.1.251.1.1.14.3.1.30ColumnbillCLP1Outread-onlymandatoryCLP1 out count.
1.3.6.1.4.1.251.1.1.14.3.1.31ColumnbillTagread-onlymandatoryThis identifies the billable SVC.
1.3.6.1.4.1.251.1.1.14.3.1.32ColumnbillStartM2read-onlymandatoryCall start date-time.
1.3.6.1.4.1.251.1.1.14.3.1.33ColumnbillEndM2read-onlymandatoryCall end date-time.
1.3.6.1.4.1.251.1.1.14.3.1.34ColumnbillFwdPCRread-onlymandatorySVC Forward Peak Cell Rate.
1.3.6.1.4.1.251.1.1.14.3.1.35ColumnbillBwdPCRread-onlymandatorySVC Backward Peak Cell Rate.
1.3.6.1.4.1.251.1.1.14.3.1.36ColumnbillFwdSCRread-onlymandatorySVC Forward Sustained Cell Rate.
1.3.6.1.4.1.251.1.1.14.3.1.37ColumnbillBwdSCRread-onlymandatorySVC Backward Sustained Cell Rate.
1.3.6.1.4.1.251.1.1.14.3.1.38ColumnbillFwdMBSread-onlymandatorySVC Forward Maximum Burst Size.
1.3.6.1.4.1.251.1.1.14.3.1.39ColumnbillBwdMBSread-onlymandatorySVC Backward Maximum Burst Size.
1.3.6.1.4.1.251.1.1.14.3.1.40ColumnbillFwdQOSread-onlymandatoryForward Quality of Service.
1.3.6.1.4.1.251.1.1.14.3.1.41ColumnbillBwdQOSread-onlymandatoryBackward Quality of Service.
1.3.6.1.4.1.251.1.1.14.4ScalarbillingControlread-writemandatoryThis object is set to start SPVC/PVC process.
1.3.6.1.4.1.251.1.1.14.7ScalarbillLostread-writemandatoryLost of billing record count.
1.3.6.1.4.1.251.1.1.14.8ScalarbillLinksread-writemandatoryThis value is bitwise billing link control.
1.3.6.1.4.1.251.1.1.14.9ScalarbillTrapControlread-writemandatoryThis object is set to enable or disable billing traps
1.3.6.1.4.1.251.1.1.14.10ScalarbillDirControlread-writemandatoryThis object is selected for uni-direction billing or bi-direction billing.
1.3.6.1.4.1.251.1.1.14.12ScalarbillingIntervalread-writemandatoryThis parameter is used to set the billing period in 15/30/60/120 minute intervals
1.3.6.1.4.1.251.1.1.15Nodedv2QeDoc
1.3.6.1.4.1.251.1.1.15.1ScalarqeDocMacAddressread-onlymandatoryMAC address of Ethernet ports.
1.3.6.1.4.1.251.1.1.15.2ScalarqeDocTunRetryPeriodread-writemandatoryNumber of seconds between retries of tunnel establishment.
1.3.6.1.4.1.251.1.1.15.3ScalarqeDocTunIdlePeriodread-writemandatoryNumber of seconds to wait without activity before clearing tunnel call.
1.3.6.1.4.1.251.1.1.15.4TableqeDocBridgeTablenot-accessiblemandatoryThis table is used to statistics and control for the bridges.
1.3.6.1.4.1.251.1.1.15.4.1RowqeDocBridgeEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.15.4.1.1ColumnqeDocBridgeLinkNoread-onlymandatoryLink number.
1.3.6.1.4.1.251.1.1.15.4.1.2ColumnqeDocBridgeEnableread-writemandatorySet to yes(1) to enable MAC bridging.
1.3.6.1.4.1.251.1.1.15.4.1.3ColumnqeDocBridgeLink0Eligibleread-writemandatoryLink 0 eligible for frames
1.3.6.1.4.1.251.1.1.15.4.1.4ColumnqeDocBridgeLink1Eligibleread-writemandatoryLink 1 eligible for frames
1.3.6.1.4.1.251.1.1.15.4.1.5ColumnqeDocBridgeLink2Eligibleread-writemandatoryLink 2 eligible for frames
1.3.6.1.4.1.251.1.1.15.4.1.6ColumnqeDocBridgeLink3Eligibleread-writemandatoryLink 3 eligible for frames
1.3.6.1.4.1.251.1.1.15.6TableqeDocTunTablenot-accessiblemandatoryThis table is used to establish and control tunnels set-up using SVCs.
1.3.6.1.4.1.251.1.1.15.6.1RowqeDocTunEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.15.6.1.1ColumnqeDocTunIndexread-writemandatoryThe tunnel index number.
1.3.6.1.4.1.251.1.1.15.6.1.2ColumnqeDocTunNameread-writemandatoryMnemonic name for tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.3ColumnqeDocTunTyperead-writemandatorySpecifies the type of tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.4ColumnqeDocTunStateread-writemandatorySet to Use pvc(2) if using with a PVC. Set to Use svc(3) if using with a SVC. Set to idle(1) to prevent tunnel being established.
1.3.6.1.4.1.251.1.1.15.6.1.5ColumnqeDocTunCallStateread-onlymandatoryState of tunnel call.
1.3.6.1.4.1.251.1.1.15.6.1.6ColumnqeDocTunInFramesread-onlymandatoryReceived frames count.
1.3.6.1.4.1.251.1.1.15.6.1.7ColumnqeDocTunOutFramesread-onlymandatoryTransmitted frames count.
1.3.6.1.4.1.251.1.1.15.6.1.8ColumnqeDocTunVPIread-onlymandatoryVPI being used for the tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.9ColumnqeDocTunVCIread-onlymandatoryVCI being used for the tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.10ColumnqeDocTunPriorityread-onlymandatoryCell priority bit value.
1.3.6.1.4.1.251.1.1.15.6.1.11ColumnqeDocTunSlotread-onlymandatoryTarget slot for tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.12ColumnqeDocTunLinkread-onlymandatoryTarget link for tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.13ColumnqeDocTunRemNetread-writemandatoryRemote network address for tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.14ColumnqeDocTunRemMaskread-writemandatoryMask for remote network.
1.3.6.1.4.1.251.1.1.15.6.1.15ColumnqeDocTunLocNetread-writemandatoryLocal network address for tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.16ColumnqeDocTunLocMaskread-writemandatoryMask for local network.
1.3.6.1.4.1.251.1.1.15.6.1.17ColumnqeDocTunRemStartSktread-writemandatorySpecifies start of socket range from remote that is allowed/barred from access to tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.18ColumnqeDocTunRemEndSktread-writemandatorySpecifies end of socket range from remote that is allowed/barred from access to tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.19ColumnqeDocTunLocStartSktread-writemandatorySpecifies start of socket range from local that is allowed/barred from access to tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.20ColumnqeDocTunLocEndSktread-writemandatorySpecifies end of socket range from local that is allowed/barred from access to tunnel.
1.3.6.1.4.1.251.1.1.15.6.1.21ColumnqeDocTunSktTyperead-writemandatorySpecifies the protocol type and whether to include or exclude frames with socket number in the specified range.
1.3.6.1.4.1.251.1.1.15.6.1.22ColumnqeDocTunDestAddressread-writemandatoryDestination address for tunnel. This is only required for SVC tunnels.
1.3.6.1.4.1.251.1.1.15.6.1.23ColumnqeDocTunDestSubAddressread-writemandatoryDestination sub-address for tunnel. This is only required for SVC tunnels.
1.3.6.1.4.1.251.1.1.15.6.1.24ColumnqeDocTunLink0Eligibleread-writemandatoryLink 0 eligible for frames
1.3.6.1.4.1.251.1.1.15.6.1.25ColumnqeDocTunLink1Eligibleread-writemandatoryLink 1 eligible for frames
1.3.6.1.4.1.251.1.1.15.6.1.26ColumnqeDocTunLink2Eligibleread-writemandatoryLink 2 eligible for frames
1.3.6.1.4.1.251.1.1.15.6.1.27ColumnqeDocTunLink3Eligibleread-writemandatoryLink 3 eligible for frames
1.3.6.1.4.1.251.1.1.15.6.1.28ColumnqeDocTunValidityread-writemandatorySetting to invalid(2) removes the row from the table.
1.3.6.1.4.1.251.1.1.15.6.1.29ColumnqeDocTunRfc1483Encapread-writemandatorySetting to yes(1) enable RFC 1483 LLC encapsulation.
1.3.6.1.4.1.251.1.1.15.6.1.31ColumnqeDocTunClpread-onlymandatoryCell loss priority bit value.
1.3.6.1.4.1.251.1.1.15.7ScalarqeDocIpAddressread-writemandatoryThe IP address of the QEDOC for management use.
1.3.6.1.4.1.251.1.1.15.8ScalarqeDocIpMaskread-writemandatoryThe mask for management use.
1.3.6.1.4.1.251.1.1.15.9ScalarqeDocIpBCastread-writemandatoryThe management broadcast address.
1.3.6.1.4.1.251.1.1.16Nodedv2SDH
1.3.6.1.4.1.251.1.1.16.1TablesdhCTablenot-accessiblemandatoryThis table is used to control sdh/Sonet configuration.
1.3.6.1.4.1.251.1.1.16.1.1RowsdhCEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.16.1.1.1ColumnsdhCLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.16.1.1.2ColumnsdhCLinkEnabread-writemandatorySet to yes(1) to enable the link.
1.3.6.1.4.1.251.1.1.16.1.1.3ColumnsdhCLoopTimerread-writemandatorySet to yes(1) to enable loop timing for this link.
1.3.6.1.4.1.251.1.1.16.1.1.4ColumnsdhCLoopDiagread-writemandatorySet to yes(1) to enable diagnostic loopback.
1.3.6.1.4.1.251.1.1.16.1.1.5ColumnsdhCLoopLineread-writemandatorySet to yes(1) to enable line loopback.
1.3.6.1.4.1.251.1.1.16.1.1.6ColumnsdhCScramblerread-writemandatorySet to no(2) to disable scramble mode for this link.
1.3.6.1.4.1.251.1.1.16.1.1.7ColumnsdhC0x55read-writemandatoryIf set to no(2) then HCS is XORed with 0x55
1.3.6.1.4.1.251.1.1.16.1.1.8ColumnsdhSonetSdhread-writemandatoryIf set to sdh(2) then sdh header is used
1.3.6.1.4.1.251.1.1.16.1.1.9ColumnsdhClearCountsread-writemandatoryClear Error Counts and Performance Parameters
1.3.6.1.4.1.251.1.1.16.1.1.10ColumnsdhReconfigread-writemandatoryPerform Reconfiguration for Link
1.3.6.1.4.1.251.1.1.16.1.1.11ColumnsdhCLpbkTimeoutread-writemandatoryThis parameter is used to set the loopback timeout in minutes.
1.3.6.1.4.1.251.1.1.16.1.1.12ColumnsdhStmStsread-writemandatorySet to 155.52(1) for STS-3c/STM-1 format
1.3.6.1.4.1.251.1.1.16.1.1.13ColumnsdhAPSOnOffread-writemandatoryIf set to on(2) then sdh APS is used
1.3.6.1.4.1.251.1.1.16.1.1.14ColumnsdhCIdleCellread-writemandatoryIdle Cell Header Contents
1.3.6.1.4.1.251.1.1.16.3TablesdhSTablenot-accessiblemandatoryThe status table for sdh/SONET.
1.3.6.1.4.1.251.1.1.16.3.1RowsdhSEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.16.3.1.1ColumnsdhSLinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.16.3.1.2ColumnsdhSTXclockread-onlymandatoryThe state of TX clock for this link.
1.3.6.1.4.1.251.1.1.16.3.1.3ColumnsdhSRXclockread-onlymandatoryThe state of RX clock for this link.
1.3.6.1.4.1.251.1.1.16.3.1.4ColumnsdhSSectLOSread-onlymandatoryThe loss of signal indicator.
1.3.6.1.4.1.251.1.1.16.3.1.5ColumnsdhSSectOOFread-onlymandatoryThe out of frame indicator.
1.3.6.1.4.1.251.1.1.16.3.1.6ColumnsdhSSectLOFread-onlymandatoryThe loss of frame indicator.
1.3.6.1.4.1.251.1.1.16.3.1.7ColumnsdhSLineAISread-onlymandatorySet to yes(1) if Line AIS detected.
1.3.6.1.4.1.251.1.1.16.3.1.8ColumnsdhSLineFERFread-onlymandatorySet to yes(1) if Line FERF detected.
1.3.6.1.4.1.251.1.1.16.3.1.9ColumnsdhSPathAISread-onlymandatorySet to yes(1) if Alarm Indication Signal detected.
1.3.6.1.4.1.251.1.1.16.3.1.10ColumnsdhSPathYellowread-onlymandatorySet to yes(1) if yellow alarm active.
1.3.6.1.4.1.251.1.1.16.3.1.11ColumnsdhSPathFERFread-onlymandatorySet to yes(1) if Far End Receive Failure detected.
1.3.6.1.4.1.251.1.1.16.3.1.12ColumnsdhSPathLOPread-onlymandatorySet to yes(1) if Loss Of Pointer detected.
1.3.6.1.4.1.251.1.1.16.3.1.13ColumnsdhSPathLabelMMread-onlymandatorySet to yes(1) if a Path Label Mismatch is detected
1.3.6.1.4.1.251.1.1.16.3.1.14ColumnsdhSExBERDefectread-onlymandatoryExcessive Bit Error Rate Defect
1.3.6.1.4.1.251.1.1.16.3.1.15ColumnsdhSPathLabelread-onlymandatoryThe Path Label.
1.3.6.1.4.1.251.1.1.16.3.1.16ColumnsdhSCellDelStateread-onlymandatoryThe Cell Delineation State
1.3.6.1.4.1.251.1.1.16.3.1.17ColumnsdhSAlarmLOSread-onlymandatorySet to yes(1) if a LOS failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.18ColumnsdhSAlarmLOFread-onlymandatorySet to yes(1) if a LOF failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.19ColumnsdhSAlarmLineAISread-onlymandatorySet to yes(1) if a Line AIS failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.20ColumnsdhSAlarmLineRFIread-onlymandatorySet to yes(1) if a Line Remote Failure Indication (Yellow Alarm) failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.21ColumnsdhSAlarmPathAISread-onlymandatorySet to yes(1) if a Path AIS failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.22ColumnsdhSAlarmPathRFIread-onlymandatorySet to yes(1) if a Path Remote Failure Indication (Yellow Alarm) failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.23ColumnsdhSAlarmLOPread-onlymandatorySet to yes(1) if a LOP failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.24ColumnsdhSAlarmPLMread-onlymandatorySet to yes(1) if a Payload Mismatch failure is declared
1.3.6.1.4.1.251.1.1.16.3.1.25ColumnsdhSExBERAlarmread-onlymandatoryExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.16.3.1.26ColumnsdhSCorrHCSread-onlymandatoryThe correctable HCS errors count.
1.3.6.1.4.1.251.1.1.16.3.1.27ColumnsdhSUnCorrHCSread-onlymandatoryThe uncorrectable HCS errors count.
1.3.6.1.4.1.251.1.1.16.4TablesdhS2Tablenot-accessiblemandatoryThe second status table for sdh/SONET.
1.3.6.1.4.1.251.1.1.16.4.1RowsdhS2Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.16.4.1.1ColumnsdhS2LinkNoread-onlymandatoryThe link number for this status.
1.3.6.1.4.1.251.1.1.16.4.1.2ColumnsdhSSectBIP8read-onlymandatorySection BIP-8 error count.
1.3.6.1.4.1.251.1.1.16.4.1.3ColumnsdhSSectESread-onlymandatorySection Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.4ColumnsdhSSectSESread-onlymandatorySection Severely Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.5ColumnsdhSLineBIP24read-onlymandatoryLine BIP-24 error count.
1.3.6.1.4.1.251.1.1.16.4.1.6ColumnsdhSLineESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.7ColumnsdhSLineSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.8ColumnsdhSLineUASread-onlymandatoryLine Unavailable Seconds
1.3.6.1.4.1.251.1.1.16.4.1.9ColumnsdhSLineFCread-onlymandatoryLine Failure Count
1.3.6.1.4.1.251.1.1.16.4.1.10ColumnsdhSPathBIP8read-onlymandatoryThe path BIP-8 count.
1.3.6.1.4.1.251.1.1.16.4.1.11ColumnsdhSPathESread-onlymandatoryPath Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.12ColumnsdhSPathSESread-onlymandatoryPath Severely Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.13ColumnsdhSPathUASread-onlymandatoryPath Unavailable Seconds
1.3.6.1.4.1.251.1.1.16.4.1.14ColumnsdhSPathFCread-onlymandatoryPath Failure Count
1.3.6.1.4.1.251.1.1.16.4.1.15ColumnsdhSLineFEBEread-onlymandatoryFar end block errors.
1.3.6.1.4.1.251.1.1.16.4.1.16ColumnsdhSLineFarEndESread-onlymandatoryFar End Line Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.17ColumnsdhSLineFarEndSESread-onlymandatoryFar End Line Severely Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.18ColumnsdhSLineFarEndUASread-onlymandatoryFar End Line Unavailable Seconds
1.3.6.1.4.1.251.1.1.16.4.1.19ColumnsdhSLineFarEndFCread-onlymandatoryFar End Line Failure Count
1.3.6.1.4.1.251.1.1.16.4.1.20ColumnsdhSPathFEBEread-onlymandatoryThe Path Far End Block Error count.
1.3.6.1.4.1.251.1.1.16.4.1.21ColumnsdhSPathFarEndESread-onlymandatoryFar End Path Errored Second
1.3.6.1.4.1.251.1.1.16.4.1.22ColumnsdhSPathFarEndSESread-onlymandatoryFar End Path Severely Errored Seconds
1.3.6.1.4.1.251.1.1.16.4.1.23ColumnsdhSPathFarEndUASread-onlymandatoryFar End Path Unavailable Seconds
1.3.6.1.4.1.251.1.1.16.4.1.24ColumnsdhSPathFarEndFCread-onlymandatoryFar End Path Failure Count
1.3.6.1.4.1.251.1.1.17Nodedv2Pvc
1.3.6.1.4.1.251.1.1.17.1TablepvcResourceTablenot-accessiblemandatoryThis table contains information about the resource available for pvcs on each link.
1.3.6.1.4.1.251.1.1.17.1.1RowpvcResourceEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.17.1.1.1ColumnpvcSlotread-onlymandatoryThe slot number.
1.3.6.1.4.1.251.1.1.17.1.1.2ColumnpvcLinkread-onlymandatoryThe link number being used for the call.
1.3.6.1.4.1.251.1.1.17.1.1.3ColumnpvcVciStartread-writemandatoryIdentifies the start of the range of PVC VCI values supported on this link.
1.3.6.1.4.1.251.1.1.17.1.1.4ColumnpvcVciEndread-writemandatoryIdentifies the end of the range of PVC VCI values supported on this link.
1.3.6.1.4.1.251.1.1.17.1.1.5ColumnpvcVpiStartread-writemandatoryIdentifies the start of the range of PVC VPI values supported on this link.
1.3.6.1.4.1.251.1.1.17.1.1.6ColumnpvcVpiEndread-writemandatoryIdentifies the end of the range of PVC VPI values supported on this link.
1.3.6.1.4.1.251.1.1.17.1.1.7ColumnpvcVpStartread-writemandatoryIdentifies the start of the range of VPs supported on this link.
1.3.6.1.4.1.251.1.1.17.1.1.8ColumnpvcVpEndread-writemandatoryIdentifies the end of the range of VPs supported on this link.
1.3.6.1.4.1.251.1.1.17.1.1.11ColumnpvcBackwardCellRateTotalread-writemandatoryThe backward total cell rate configured for PVCs on this link. Note that this object is in cells per second (CPS).
1.3.6.1.4.1.251.1.1.17.1.1.13ColumnpvcLinkQoSread-writemandatoryThis specifies the type of ATM link.
1.3.6.1.4.1.251.1.1.17.1.1.14ColumnpvcMolnVpiread-writemandatoryThis is the VPI for the management overlay network.
1.3.6.1.4.1.251.1.1.17.1.1.15ColumnpvcMolnVciread-writemandatoryThis is the VCI for the management overlay network.
1.3.6.1.4.1.251.1.1.17.1.1.16ColumnpvcLowPriOverbookFactorread-writemandatoryThis is the percentage of low priority traffic overbook factor.
1.3.6.1.4.1.251.1.1.17.2TablepvcTablenot-accessiblemandatoryThis table contains information on each PVC.
1.3.6.1.4.1.251.1.1.17.2.1RowpvcEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.17.2.1.1ColumnpvcDSlotread-writemandatoryThe destination slot for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.2ColumnpvcDLinkread-writemandatoryThe destination link for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.3ColumnpvcDvciread-writemandatoryThe destination virtual circuit identifier for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.4ColumnpvcDvpiread-writemandatoryThe destination virtual path identifier for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.5ColumnpvcSSlotread-writemandatoryThe source slot for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.6ColumnpvcSLinkread-writemandatoryThe source link for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.7ColumnpvcSvciread-writemandatoryThe source virtual circuit identifier for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.8ColumnpvcSvpiread-writemandatoryThe source virtual path identifier for the PVC.
1.3.6.1.4.1.251.1.1.17.2.1.9ColumnpvcForwardPeakCellRateread-writemandatoryForward Peak Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.10ColumnpvcForwardPeakSizeread-writemandatoryForward Peak Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.11ColumnpvcForwardPeakModeread-writemandatoryForward Peak Mode
1.3.6.1.4.1.251.1.1.17.2.1.12ColumnpvcBackwardPeakCellRateread-writemandatoryBackward Peak Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.13ColumnpvcBackwardPeakSizeread-writemandatoryBackward Peak Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.14ColumnpvcBackwardPeakModeread-writemandatoryBackward Peak Mode
1.3.6.1.4.1.251.1.1.17.2.1.15ColumnpvcForwardSustainedCellRateread-writemandatoryForward Sustained Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.16ColumnpvcForwardSustainedSizeread-writemandatoryForward Sustained Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.17ColumnpvcForwardSustainedModeread-writemandatoryForward Sustained Mode
1.3.6.1.4.1.251.1.1.17.2.1.18ColumnpvcBackwardSustainedCellRateread-writemandatoryBackward Sustained Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.19ColumnpvcBackwardSustainedSizeread-writemandatoryBackward Sustained Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.20ColumnpvcBackwardSustainedModeread-writemandatoryBackward Sustained Mode
1.3.6.1.4.1.251.1.1.17.2.1.21ColumnpvcAuxForwardPeakCellRateread-writemandatoryAuxiliary Forward Peak Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.22ColumnpvcAuxForwardPeakSizeread-writemandatoryAuxiliary Forward Peak Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.23ColumnpvcAuxForwardPeakModeread-writemandatoryAuxiliary Forward Peak Mode
1.3.6.1.4.1.251.1.1.17.2.1.24ColumnpvcAuxBackwardPeakCellRateread-writemandatoryAuxiliary Backward Peak Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.25ColumnpvcAuxBackwardPeakSizeread-writemandatoryAuxiliary Backward Peak Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.26ColumnpvcAuxBackwardPeakModeread-writemandatoryAuxiliary Backward Peak Mode
1.3.6.1.4.1.251.1.1.17.2.1.27ColumnpvcAuxForwardSustainedCellRateread-writemandatoryAuxiliary Forward Sustained Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.28ColumnpvcAuxForwardSustainedSizeread-writemandatoryAuxiliary Forward Sustained Bucket Size (Cells)
1.3.6.1.4.1.251.1.1.17.2.1.29ColumnpvcAuxForwardSustainedModeread-writemandatoryAuxiliary Forward Sustained Mode
1.3.6.1.4.1.251.1.1.17.2.1.30ColumnpvcAuxBackwardSustainedCellRateread-writemandatoryAuxiliary Backward Sustained Cell Rate (CPS)
1.3.6.1.4.1.251.1.1.17.2.1.31ColumnpvcAuxBackwardSustainedSizeread-writemandatoryAuxiliary Backward Sustained Bucket Size
1.3.6.1.4.1.251.1.1.17.2.1.32ColumnpvcAuxBackwardSustainedModeread-writemandatoryAuxiliary Backward Sustained Mode
1.3.6.1.4.1.251.1.1.17.2.1.33ColumnpvcQoSClassread-writemandatoryCBR(1) is a constant bit rate service, vbr-high(2) is variable bit rate with high priority, vbr-med(3) has low priority, vbr-low(4) is a `best effort' service …
1.3.6.1.4.1.251.1.1.17.2.1.34ColumnpvcStatusread-writemandatoryIf this object is set to invalid(2), the PVC entry is removed. Set to start-PVC(3) to activate the PVC. When the state changes to running(5) then the PVC is su…
1.3.6.1.4.1.251.1.1.17.2.1.35ColumnpvcMulticastread-writemandatoryIf this object is set to no, multicast is not allowed; otherwise, multicast is allowed.
1.3.6.1.4.1.251.1.1.17.2.1.36ColumnpvcInternalVpiread-onlymandatoryThis object indicates the internal VPI value that the source side of multicast tree ranslates its orignal VPI to.
1.3.6.1.4.1.251.1.1.17.2.1.37ColumnpvcInternalVciread-onlymandatoryThis object indicates the internal VCI value that the source side of multicast tree ranslates its orignal VCI to.
1.3.6.1.4.1.251.1.1.17.2.1.38ColumnpvcNumLeavesread-onlymandatoryThis object indicates the number of leaves this multicast tree currently contains.
1.3.6.1.4.1.251.1.1.17.2.1.39ColumnpvcDirectionread-writemandatoryThis object determines if a multicast PVC is to be unidirectional or bidirectional
1.3.6.1.4.1.251.1.1.18Nodedv2Svc
1.3.6.1.4.1.251.1.1.18.1ScalarsvcMaxPtPtConnectionsread-writemandatoryThe maximum number of point-to-point connections.
1.3.6.1.4.1.251.1.1.18.2ScalarsvcMaxPtMptConnectionsread-writemandatoryThe maximum number of point-to-multipoint connections.
1.3.6.1.4.1.251.1.1.18.3ScalarsvcMaxPtMptPartiesread-writemandatoryThe maximum number of parties in a point-to-multipoint connection.
1.3.6.1.4.1.251.1.1.18.6TablesvcResourceTablenot-accessiblemandatoryThis table contains information about the resource available for svcs on each link.
1.3.6.1.4.1.251.1.1.18.6.1RowsvcResourceEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.6.1.1ColumnsvcSAPread-onlymandatoryIdentifies the SAP.
1.3.6.1.4.1.251.1.1.18.6.1.2ColumnsvcHiLoread-writemandatorySelect VPI/VCI values from low to high or high to low
1.3.6.1.4.1.251.1.1.18.6.1.3ColumnsvcVciStartread-onlymandatoryIdentifies the start of the range of SVC VCI values supported on this link.
1.3.6.1.4.1.251.1.1.18.6.1.4ColumnsvcVciEndread-onlymandatoryIdentifies the end of the range of SVC VCI values supported on this link.
1.3.6.1.4.1.251.1.1.18.6.1.5ColumnsvcVpiStartread-writemandatoryIdentifies the start of the range of SVC VPI values supported on this link.
1.3.6.1.4.1.251.1.1.18.6.1.6ColumnsvcVpiEndread-writemandatoryIdentifies the end of the range of SVC VPI values supported on this link.
1.3.6.1.4.1.251.1.1.18.6.1.7ColumnsvcVpStartread-writemandatoryIdentifies the start of the range of SVPs supported on this link.
1.3.6.1.4.1.251.1.1.18.6.1.8ColumnsvcVpEndread-writemandatoryIdentifies the end of the range of SVPs supported on this link.
1.3.6.1.4.1.251.1.1.18.6.1.11ColumnsvcBackwardCellRateTotalread-writemandatoryThe backward total cell rate configured for SVCs on this link. Note that this object is in cells per second (CPS).
1.3.6.1.4.1.251.1.1.18.6.1.12ColumnsvcBackwardCellRateAvailableread-onlymandatoryThe backward cell rate available for SVCs on this link. Note that this object is in cells per second (CPS).
1.3.6.1.4.1.251.1.1.18.6.1.13ColumnsvcSigVciread-writemandatoryThe VCI used for signalling.
1.3.6.1.4.1.251.1.1.18.6.1.14ColumnsvcSigVpiread-writemandatoryThe VPI used for signalling.
1.3.6.1.4.1.251.1.1.18.6.1.15ColumnsvcSAPStatusread-writemandatorySelect on(4) to activate the SAP, off(1) to deactivate, reconfigure(2) to hot reconfigure the vci/vpi ranges and reset(3) to clear all calls on the SAP.
1.3.6.1.4.1.251.1.1.18.6.1.16ColumnsvcCDVTSizeread-writemandatoryCell Delay Variation Tolerance size.
1.3.6.1.4.1.251.1.1.18.6.1.17ColumnsvcIntTyperead-writemandatoryInterface type - NETWORK or USER.
1.3.6.1.4.1.251.1.1.18.6.1.18ColumnsvcPolicingread-writemandatoryPolicing - ON or OFF
1.3.6.1.4.1.251.1.1.18.6.1.19ColumnsvcLowPriOverbookFactorread-writemandatoryThis is the percentage of low priority traffic overbook factor.
1.3.6.1.4.1.251.1.1.18.6.1.20ColumnsvcMaxSapConnread-writemandatoryMaximum SVCs this SAP
1.3.6.1.4.1.251.1.1.18.6.1.21ColumnsvcCurSapConnread-onlymandatoryCurrent SVC count this SAP
1.3.6.1.4.1.251.1.1.18.6.1.22ColumnsvcLinkNoread-writemandatoryThis is the physical link number associated with this SAP
1.3.6.1.4.1.251.1.1.18.6.1.23ColumnsvcVpiMappingread-writemandatoryVPI and VPCI mapping status
1.3.6.1.4.1.251.1.1.18.6.1.24ColumnsvcQosRouteread-writemandatoryQoS based route
1.3.6.1.4.1.251.1.1.18.6.1.25ColumnsvcSwtchread-writemandatoryUNI Interface Type
1.3.6.1.4.1.251.1.1.18.6.1.26ColumnsvcRestartread-writemandatorySend Restart when link is up
1.3.6.1.4.1.251.1.1.18.6.1.27ColumnsvcE164Addrread-writemandatoryThe E.164 address for this SAP
1.3.6.1.4.1.251.1.1.18.6.1.28ColumnsvcAutoSapOffread-writemandatoryThis option allows a Sap Status to be automatically turned OFF after T309 expiry. Select Yes(1) if a sap (which was ON before) is to be turned OFF after T309 e…
1.3.6.1.4.1.251.1.1.18.7TablesvcTablenot-accessiblemandatoryThis table contains information on each on SVC.
1.3.6.1.4.1.251.1.1.18.7.1RowsvcEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.7.1.1ColumnsvcIdread-onlymandatoryThe svc ID number
1.3.6.1.4.1.251.1.1.18.7.1.2ColumnsvcDSlotread-onlymandatoryThe destination slot of the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.3ColumnsvcDLinkread-onlymandatoryThe destination link of the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.4ColumnsvcDvciread-onlymandatoryThe destination virtual circuit identifier for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.5ColumnsvcDvpiread-onlymandatoryThe destination virtual path identifier for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.6ColumnsvcDE164read-onlymandatoryThe destination E.164 address for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.7ColumnsvcDE164Subread-onlymandatoryThe destination sub-address for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.8ColumnsvcSSlotread-onlymandatoryThe source slot of the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.9ColumnsvcSLinkread-onlymandatoryThe source link of the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.10ColumnsvcSvciread-onlymandatoryThe source virtual circuit identifier for a SVC.
1.3.6.1.4.1.251.1.1.18.7.1.11ColumnsvcSvpiread-onlymandatoryThe source virtual path identifier for a SVC.
1.3.6.1.4.1.251.1.1.18.7.1.12ColumnsvcSE164read-onlymandatoryThe source E.164 address for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.13ColumnsvcSE164Subread-onlymandatoryThe source sub-address for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.14ColumnsvcForwardPeakCellRateread-onlymandatoryThe forward user cell rate for a SVC. The forward user cell rate is a measurement of bandwidth available to the initiating user to transfer information to the …
1.3.6.1.4.1.251.1.1.18.7.1.15ColumnsvcForwardPeakModeread-onlymandatorySVC/SVP Forward Peak Mode
1.3.6.1.4.1.251.1.1.18.7.1.16ColumnsvcBackwardPeakCellRateread-onlymandatoryThe backward user cell rate for a SVC. The backward user cell rate is a measurement of bandwidth available to the responding user to transfer information to th…
1.3.6.1.4.1.251.1.1.18.7.1.17ColumnsvcBackwardPeakModeread-onlymandatorySVC/SVP Backward Peak Mode
1.3.6.1.4.1.251.1.1.18.7.1.18ColumnsvcForwardSustainableCellRateread-onlymandatoryThe sustainable forward cell rate for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.19ColumnsvcForwardMaxBurstSizeread-onlymandatoryThe forward maximum burst size for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.20ColumnsvcForwardSustainableModeread-onlymandatorySVC/SVP Forward Sustained Mode
1.3.6.1.4.1.251.1.1.18.7.1.21ColumnsvcBackwardSustainableCellRateread-onlymandatoryThe sustainable backward cell rate for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.22ColumnsvcBackwardMaxBurstSizeread-onlymandatoryThe backward maximum burst size for the SVC.
1.3.6.1.4.1.251.1.1.18.7.1.23ColumnsvcBackwardSustainableModeread-onlymandatorySVC/SVP Backward Sustained Mode
1.3.6.1.4.1.251.1.1.18.7.1.24ColumnsvcQoSClassread-onlymandatoryCBR(1) is a constant bit rate service, vbr-high(2) is variable bit rate with high priority, vbr-med(3) has low priority, vbr-low(4) is a `best effort' service …
1.3.6.1.4.1.251.1.1.18.7.1.25ColumnsvcBillTagread-onlymandatoryThis identifies the billable SVC.
1.3.6.1.4.1.251.1.1.18.7.1.26ColumnsvcDurationread-onlymandatoryDuration of the SVC in milliseconds.
1.3.6.1.4.1.251.1.1.18.7.1.27ColumnsvcTyperead-onlymandatoryThe type of SVC.
1.3.6.1.4.1.251.1.1.18.7.1.28ColumnsvcStatusread-writemandatoryIf this object is set to invalid (2), the SVC is cleared and the entry is removed. If set to active(4) then the SVC is active.
1.3.6.1.4.1.251.1.1.18.7.1.29ColumnsvcNumLeavesread-onlymandatoryNumber of multicast leaves
1.3.6.1.4.1.251.1.1.18.7.1.30ColumnsvcInternalVpiread-onlymandatoryinternal VPI used for multicast operation
1.3.6.1.4.1.251.1.1.18.7.1.31ColumnsvcInternalVciread-onlymandatoryinternal VCI used for multicast operation
1.3.6.1.4.1.251.1.1.18.8TablesPvcTablenot-accessiblemandatoryThis table contains information on Semi-Permanent Virtual Circuits (SPVCs).
1.3.6.1.4.1.251.1.1.18.8.1RowsPvcEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.8.1.1ColumnsPvcIdread-writemandatorySlot-unique SPVC identifier.
1.3.6.1.4.1.251.1.1.18.8.1.2ColumnsPvcCallIdread-onlymandatoryCall identifier.
1.3.6.1.4.1.251.1.1.18.8.1.3ColumnsPvcLinkread-writemandatoryThe physical link for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.4ColumnsPvcAddressread-writemandatoryThe E.164 address for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.5ColumnsPvcForwardPeakCellRateread-writemandatoryThe forward user cell rate for an SPVC. The forward user cell rate is a measurement of bandwidth available to the initiating user to transfer information to th…
1.3.6.1.4.1.251.1.1.18.8.1.6ColumnsPvcForwardPeakModeread-writemandatorySPVC/SPVP Forward Peak Mode
1.3.6.1.4.1.251.1.1.18.8.1.7ColumnsPvcBackwardPeakCellRateread-writemandatoryThe backward user cell rate for an SPVC. The backward user cell rate is a measurement of bandwidth available to the responding user to transfer information to …
1.3.6.1.4.1.251.1.1.18.8.1.8ColumnsPvcBackwardPeakModeread-writemandatorySPVC/SPVP Backward Peak Mode
1.3.6.1.4.1.251.1.1.18.8.1.9ColumnsPvcForwardSustainableCellRateread-writemandatoryThe sustainable forward cell rate for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.10ColumnsPvcForwardMaxBurstSizeread-writemandatoryThe forward maximum burst size for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.11ColumnsPvcForwardSustainableModeread-writemandatorySPVC/SPVP Forward Sustained Mode
1.3.6.1.4.1.251.1.1.18.8.1.12ColumnsPvcBackwardSustainableCellRateread-writemandatoryThe sustainable backward cell rate for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.13ColumnsPvcBackwardMaxBurstSizeread-writemandatoryThe backward maximum burst size for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.14ColumnsPvcBackwardSustainableModeread-writemandatorySPVC/SPVP Backward Sustained Mode
1.3.6.1.4.1.251.1.1.18.8.1.15ColumnsPvcQoSClassread-writemandatoryCBR(1) is a constant bit rate service, vbr-high(2) is variable bit rate with high priority, vbr-med(3) has low priority, vbr-low(4) has low priority and the ce…
1.3.6.1.4.1.251.1.1.18.8.1.16ColumnsPvcSourceVciread-writemandatoryThe source virtual circuit identifier for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.17ColumnsPvcSourceVpiread-writemandatoryThe source virtual path identifier for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.18ColumnsPvcTargetVciread-writemandatoryThe target virtual circuit identifier for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.19ColumnsPvcTargetVpiread-writemandatoryThe target virtual path identifier for the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.20ColumnsPvcRetryread-writemandatoryRetry timeout. Zero represents an infinite timeout.
1.3.6.1.4.1.251.1.1.18.8.1.21ColumnsPvcConnectTimeread-onlymandatoryConnect time in ms.
1.3.6.1.4.1.251.1.1.18.8.1.22ColumnsPvcNumberRetriesread-writemandatoryNumber of retries to attempt. Zero represents no limit.
1.3.6.1.4.1.251.1.1.18.8.1.23ColumnsPvcFailuresread-onlymandatoryA count of the SPVC setup failures.
1.3.6.1.4.1.251.1.1.18.8.1.24ColumnsPvcAlertFailuresread-writemandatoryDescribes the circumstances under which to issue an Alert message to the NMS.
1.3.6.1.4.1.251.1.1.18.8.1.25ColumnsPvcCauseDiagread-onlymandatoryCause and diagnostic codes.
1.3.6.1.4.1.251.1.1.18.8.1.26ColumnsPvcTyperead-onlymandatoryIf the SPVC entry is passive, it will not try to initiate a call. An active will attempt to build an SPVC at intervals set by the retry field.
1.3.6.1.4.1.251.1.1.18.8.1.27ColumnsPvcCallStateread-writemandatorySets the state of the SPVC. Set the value to invalid(3) to tear down the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.28ColumnsPvcStatusread-onlymandatoryDescribes the state of the SPVC.
1.3.6.1.4.1.251.1.1.18.8.1.29ColumnsPvcCauseDiagCoderead-onlymandatoryCause and diagnostic codes as defined in UNI-3.0 Annex E .
1.3.6.1.4.1.251.1.1.18.8.1.30ColumnsPvcMulticastread-writemandatorypt-pt - point-to-point SPVC; pt-mpt - point-to-multipoint SPVC; bidirect-root: pt-mpt birection root.
1.3.6.1.4.1.251.1.1.18.9TablesvcQ93bStatTablenot-accessiblemandatoryThis table contains statistical protocol information for each link.
1.3.6.1.4.1.251.1.1.18.9.1RowsvcQ93bStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.9.1.1ColumnsvcQ93bStatSAPread-onlymandatoryThis is the layer 3 Service Access Point for the link.
1.3.6.1.4.1.251.1.1.18.9.1.2ColumnsvcQ93bStatActiveread-onlymandatoryNumber of calls currently active on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.3ColumnsvcQ93bStatAccumalativeread-onlymandatoryTotal number of calls established on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.4ColumnsvcQ93bStatCallProcTxread-onlymandatoryCall Proceeding pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.5ColumnsvcQ93bStatConnTxread-onlymandatoryConnect pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.6ColumnsvcQ93bStatConnAckTxread-onlymandatoryConnect Acknowledge pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.7ColumnsvcQ93bStatSetupTxread-onlymandatorySetup pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.8ColumnsvcQ93bStatRelTxread-onlymandatoryRelease pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.9ColumnsvcQ93bStatRelCmpltTxread-onlymandatoryRelease Complete pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.10ColumnsvcQ93bStatRstTxread-onlymandatoryRestart pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.11ColumnsvcQ93bStatRstAckTxread-onlymandatoryRestart Acknowledge pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.12ColumnsvcQ93bStatStatTxread-onlymandatoryStatus pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.13ColumnsvcQ93bStatStatEnqTxread-onlymandatoryStatus Enquiry pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.14ColumnsvcQ93bStatAddPtyTxread-onlymandatoryAdd Party pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.15ColumnsvcQ93bStatAddPtyAckTxread-onlymandatoryAdd Party Acknowledge pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.16ColumnsvcQ93bStatAddPtyRejTxread-onlymandatoryAdd Party Reject pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.17ColumnsvcQ93bStatDropPtyTxread-onlymandatoryDrop Party pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.18ColumnsvcQ93bStatDropPtyAckTxread-onlymandatoryDrop Party Acknowledge pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.19ColumnsvcQ93bStatLstCauseTxread-onlymandatoryLast cause code transmitted.
1.3.6.1.4.1.251.1.1.18.9.1.20ColumnsvcQ93bStatLstDiagTxread-onlymandatoryLast diagnostic code transmitted.
1.3.6.1.4.1.251.1.1.18.9.1.21ColumnsvcQ93bStatCallProcRxread-onlymandatoryCall Proceeding pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.22ColumnsvcQ93bStatConnRxread-onlymandatoryConnect pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.23ColumnsvcQ93bStatConnAckRxread-onlymandatoryConnect Acknowledge pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.24ColumnsvcQ93bStatSetupRxread-onlymandatorySetup pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.25ColumnsvcQ93bStatRelRxread-onlymandatoryRelease pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.26ColumnsvcQ93bStatRelCmpltRxread-onlymandatoryRelease Complete pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.27ColumnsvcQ93bStatRstRxread-onlymandatoryRestart pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.28ColumnsvcQ93bStatRstAckRxread-onlymandatoryRestart Acknowledge pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.29ColumnsvcQ93bStatStatRxread-onlymandatoryStatus pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.30ColumnsvcQ93bStatStatEnqRxread-onlymandatoryStatus Enquiry pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.31ColumnsvcQ93bStatAddPtyRxread-onlymandatoryAdd Party pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.32ColumnsvcQ93bStatAddPtyAckRxread-onlymandatoryAdd Party Acknowledge pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.33ColumnsvcQ93bStatAddPtyRejRxread-onlymandatoryAdd Party Reject pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.34ColumnsvcQ93bStatDropPtyRxread-onlymandatoryDrop Party pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.35ColumnsvcQ93bStatDropPtyAckRxread-onlymandatoryDrop Party Acknowledge pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.36ColumnsvcQ93bStatLstCauseRxread-onlymandatoryLast cause code received.
1.3.6.1.4.1.251.1.1.18.9.1.37ColumnsvcQ93bStatLstDiagRxread-onlymandatoryLast diagnostic code received.
1.3.6.1.4.1.251.1.1.18.9.1.38ColumnsvcQ93bStatClrread-writemandatoryClear Q.93B statistics for this SAP.
1.3.6.1.4.1.251.1.1.18.9.1.39ColumnsvcQ93bStatDiagTxread-onlymandatoryTx SAP diagnostic codes
1.3.6.1.4.1.251.1.1.18.9.1.40ColumnsvcQ93bStatDiagRxread-onlymandatoryRx SAP diagnostic codes
1.3.6.1.4.1.251.1.1.18.10TablesvcQsaalStatTablenot-accessiblemandatoryThis table contains protocol information for the Q.SAAL layer for each link.
1.3.6.1.4.1.251.1.1.18.10.1RowsvcQsaalStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.10.1.1ColumnsvcQsaalStatSAPread-onlymandatoryThis is the layer 3 Service Access Point for the link.
1.3.6.1.4.1.251.1.1.18.10.1.2ColumnsvcQsaalStatOutSduDiscread-onlymandatoryOutgoing SDUs discarded.
1.3.6.1.4.1.251.1.1.18.10.1.3ColumnsvcQsaalStatInPduErrread-onlymandatoryNumber of incoming PDUs with a reception error.
1.3.6.1.4.1.251.1.1.18.10.1.4ColumnsvcQsaalStatInPduDiscread-onlymandatoryNumber of incoming PDUs discarded.
1.3.6.1.4.1.251.1.1.18.10.1.5ColumnsvcQsaalStatOutPduErrread-onlymandatoryNumber of outgoing PDUs with a transmission error.
1.3.6.1.4.1.251.1.1.18.10.1.6ColumnsvcQsaalStatOutPduDiscread-onlymandatoryNumber of outgoing PDUs discarded.
1.3.6.1.4.1.251.1.1.18.10.1.7ColumnsvcQsaalStatBgnTxread-onlymandatoryBGN pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.8ColumnsvcQsaalStatBgakTxread-onlymandatoryBGAK pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.9ColumnsvcQsaalStatBgrejTxread-onlymandatoryBGREJ pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.10ColumnsvcQsaalStatEndTxread-onlymandatoryEND pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.11ColumnsvcQsaalStatRsTxread-onlymandatoryRS pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.12ColumnsvcQsaalStatRsakTxread-onlymandatoryRSAK pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.13ColumnsvcQsaalStatSdTxread-onlymandatorySD pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.14ColumnsvcQsaalStatSdpTxread-onlymandatorySDP pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.15ColumnsvcQsaalStatPollTxread-onlymandatoryPOLL pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.16ColumnsvcQsaalStatStatTxread-onlymandatorySTAT pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.17ColumnsvcQsaalStatUstatTxread-onlymandatoryUSTAT pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.18ColumnsvcQsaalStatUdTxread-onlymandatoryUD pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.19ColumnsvcQsaalStatMdTxread-onlymandatoryMD pdus transmitted on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.20ColumnsvcQsaalStatBgnRxread-onlymandatoryBGN pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.21ColumnsvcQsaalStatBgakRxread-onlymandatoryBGAK pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.22ColumnsvcQsaalStatBgrejRxread-onlymandatoryBGREJ pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.23ColumnsvcQsaalStatEndRxread-onlymandatoryEND pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.24ColumnsvcQsaalStatRsRxread-onlymandatoryRS pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.25ColumnsvcQsaalStatRsakRxread-onlymandatoryRSAK pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.26ColumnsvcQsaalStatSdRxread-onlymandatorySD pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.27ColumnsvcQsaalStatSdpRxread-onlymandatorySDP pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.28ColumnsvcQsaalStatPollRxread-onlymandatoryPOLL pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.29ColumnsvcQsaalStatStatRxread-onlymandatorySTAT pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.30ColumnsvcQsaalStatUstatRxread-onlymandatoryUSTAT pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.31ColumnsvcQsaalStatUdRxread-onlymandatoryUD pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.32ColumnsvcQsaalStatMdRxread-onlymandatoryMD pdus received on this SAP.
1.3.6.1.4.1.251.1.1.18.10.1.33ColumnsvcQsaalStatClrread-writemandatoryClear statistics for this SAP.
1.3.6.1.4.1.251.1.1.18.11ScalarsvcQsaalTmrPollread-writemandatorySSCOP Timer_POLL (8=800ms).
1.3.6.1.4.1.251.1.1.18.12ScalarsvcQsaalTmrKeepAliveread-writemandatorySSCOP Timer_KEEPALIVE (20=2seconds).
1.3.6.1.4.1.251.1.1.18.13ScalarsvcQsaalTmrNoResponseread-writemandatorySSCOP Timer_NORESPONSE (100=10seconds).
1.3.6.1.4.1.251.1.1.18.14ScalarsvcQsaalTmrCCread-writemandatorySSCOP Timer_CC (20=2seconds).
1.3.6.1.4.1.251.1.1.18.15ScalarsvcQsaalMaxPDread-writemandatorySSCOP Maximum PD.
1.3.6.1.4.1.251.1.1.18.16ScalarsvcQ93bTmrT303read-writemandatoryQ.93B T303 (40=4seconds).
1.3.6.1.4.1.251.1.1.18.17ScalarsvcQ93bTmrT310read-writemandatoryQ.93B T310 (200=20seconds).
1.3.6.1.4.1.251.1.1.18.18ScalarsvcQ93bTmrT308read-writemandatoryQ.93B T308 (300=30seconds).
1.3.6.1.4.1.251.1.1.18.19ScalarsvcQ93bTmrT309read-writemandatoryQ.93B T309 (150=15seconds).
1.3.6.1.4.1.251.1.1.18.20ScalarmaxOutstandingread-writemandatoryMax Outgoing Outstanding Calls.
1.3.6.1.4.1.251.1.1.18.21ScalarsvcLoadRouteread-writemandatoryPoke point for loading routing tables
1.3.6.1.4.1.251.1.1.18.22ScalarsvcHalfConTimerread-writemandatorySVC half connect recovery poll timer
1.3.6.1.4.1.251.1.1.18.23ScalarsvcHalfConCntread-onlymandatorySVC half connect counter
1.3.6.1.4.1.251.1.1.18.24ScalarsvcQ93bTmrT398read-writemandatoryQ.93B T398 (40= 4 seconds).
1.3.6.1.4.1.251.1.1.18.25ScalarsvcQ93bTmrT399read-writemandatoryQ.93B T399 (140= 14 seconds).
1.3.6.1.4.1.251.1.1.18.26ScalarsvcRetryPeriodread-writemandatoryRetry Period
1.3.6.1.4.1.251.1.1.18.27TablesvcCellRateTablenot-accessiblemandatoryThis table contains information about the limitations on Cell Rates on link
1.3.6.1.4.1.251.1.1.18.27.1RowsvcCellRateEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.27.1.1ColumnsvcCRLinkNoread-onlymandatoryThis is the physical link number associated with this SAP
1.3.6.1.4.1.251.1.1.18.27.1.2ColumnsvcPCRCLP01Maxread-writemandatoryPCRCLP01 Max(0 disables checking)
1.3.6.1.4.1.251.1.1.18.27.1.3ColumnsvcSCRMaxread-writemandatorySCR Max(0 disables checking)
1.3.6.1.4.1.251.1.1.18.27.1.4ColumnsvcMBSMaxread-writemandatoryMBS Max(0 disables checking)
1.3.6.1.4.1.251.1.1.18.28TablesvcTrafficTablenot-accessiblemandatoryThis table contains information about the limitations on Cell Rates on link
1.3.6.1.4.1.251.1.1.18.28.1RowsvcTrafficEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.18.28.1.1ColumnsvcTLinkNoread-onlymandatoryLnk Number
1.3.6.1.4.1.251.1.1.18.28.1.2ColumnsvcCBRallowedread-writemandatoryAllows or disallows CBR traffic
1.3.6.1.4.1.251.1.1.18.28.1.3ColumnsvcVBRHallowedread-writemandatoryAllows or disallows VBR High traffic
1.3.6.1.4.1.251.1.1.18.28.1.4ColumnsvcVBRMallowedread-writemandatoryAllows or disallows VBR Med traffic
1.3.6.1.4.1.251.1.1.18.28.1.5ColumnsvcVBRLUBRallowedread-writemandatoryAllows or disallows VBR Low/UBR traffic
1.3.6.1.4.1.251.1.1.18.28.1.6ColumnsvcVBRLUBRsubtractpercentread-writemandatorySpecifies a percentage of BW to be subtracted for VBR Low/UBR traffic
1.3.6.1.4.1.251.1.1.19Nodedv2CE
1.3.6.1.4.1.251.1.1.19.1TableceTablenot-accessiblemandatoryConfiguration Table for dv2CE Links
1.3.6.1.4.1.251.1.1.19.1.1RowceEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.19.1.1.1ColumnceLinkNoread-onlymandatoryLink Number for Table Entry
1.3.6.1.4.1.251.1.1.19.1.1.2ColumnceEnableread-writemandatorySetting to yes(1) enables the Link
1.3.6.1.4.1.251.1.1.19.1.1.3ColumnceModeread-writemandatoryService Clock Recovery Mode
1.3.6.1.4.1.251.1.1.19.1.1.4ColumncePriorityread-onlymandatorySet to high for normal CBR operation
1.3.6.1.4.1.251.1.1.19.1.1.5ColumncePvcValidread-onlymandatoryIndicates if valid PVC exists for Link
1.3.6.1.4.1.251.1.1.19.1.1.6ColumnceDstSlotread-onlymandatoryDestination Slot for PVC
1.3.6.1.4.1.251.1.1.19.1.1.7ColumnceDstLinkread-onlymandatoryDestination Link for PVC
1.3.6.1.4.1.251.1.1.19.1.1.8ColumnceDstVpiread-onlymandatoryDestination VPI for PVC
1.3.6.1.4.1.251.1.1.19.1.1.9ColumnceDstVciread-onlymandatoryDestination VCI for PVC
1.3.6.1.4.1.251.1.1.19.1.1.10ColumnceCDVread-writemandatoryCell Delay Variation Tolerance
1.3.6.1.4.1.251.1.1.19.1.1.11ColumnceCDVMaxread-writemandatoryCell Delay Variation Tolerance
1.3.6.1.4.1.251.1.1.19.1.1.24ColumnceMulticastread-onlymandatoryIs link part of multicast tree
1.3.6.1.4.1.251.1.1.19.1.1.25ColumnceXhIntread-onlymandatoryXH Interface for Link
1.3.6.1.4.1.251.1.1.19.2TableceStatTablenot-accessiblemandatorystatus information about the dv2CE.
1.3.6.1.4.1.251.1.1.19.2.1RowceStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.19.2.1.1ColumnceStatPortNoread-onlymandatoryLink Number for Table Entry
1.3.6.1.4.1.251.1.1.19.2.1.2ColumnceStatResetread-writemandatoryClear Statistics for Link
1.3.6.1.4.1.251.1.1.19.2.1.3ColumnceStatTxStateread-onlymandatoryIndicates if data is being received and segmented
1.3.6.1.4.1.251.1.1.19.2.1.4ColumnceStatRxStateread-onlymandatoryIndicates if data being reassembled and transmitted
1.3.6.1.4.1.251.1.1.19.2.1.5ColumnceTxCntread-onlymandatoryCount of Cells transmitted from switch fabric
1.3.6.1.4.1.251.1.1.19.2.1.6ColumnceRxCntread-onlymandatoryCount of Cells received into switch fabric
1.3.6.1.4.1.251.1.1.19.2.1.7ColumnceOflCntread-onlymandatoryCount of 1S intervals during which RX FIFO overflowed
1.3.6.1.4.1.251.1.1.19.2.1.8ColumnceUflCntread-onlymandatoryCount of 1S intervals during which RX FIFO underflowed
1.3.6.1.4.1.251.1.1.19.2.1.9ColumnceDisCntread-onlymandatoryCount of 1S intervals during which cells were discarded
1.3.6.1.4.1.251.1.1.19.2.1.10ColumnceInvCntread-onlymandatoryCount of 1S intervals during which cells were invented
1.3.6.1.4.1.251.1.1.19.2.1.11ColumnceResCntread-onlymandatoryCount of 1S intervals during which AAL1 resync occurred
1.3.6.1.4.1.251.1.1.19.2.1.12ColumnceFifoLvlCntread-onlymandatoryNumber of Cells currently in FIFO
1.3.6.1.4.1.251.1.1.19.21ScalarcePriValread-onlymandatoryPrimary Clock Valid
1.3.6.1.4.1.251.1.1.19.22ScalarceSecValread-onlymandatorySecondary Clock Valid
1.3.6.1.4.1.251.1.1.19.23ScalarceClkSelread-onlymandatoryClock Select
1.3.6.1.4.1.251.1.1.19.24ScalarceClkInpread-onlymandatoryIs there clock input
1.3.6.1.4.1.251.1.1.19.25ScalarceStr3read-onlymandatoryIs there STR3
1.3.6.1.4.1.251.1.1.20Nodedv2VE
1.3.6.1.4.1.251.1.1.20.1TableveTablenot-accessiblemandatoryConfiguration Table for dv2VE Links
1.3.6.1.4.1.251.1.1.20.1.1RowveEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.20.1.1.1ColumnveLinkNoread-onlymandatoryLink Number for Table Entry
1.3.6.1.4.1.251.1.1.20.1.1.2ColumnveEnableread-writemandatorySetting to yes(1) enables the Link
1.3.6.1.4.1.251.1.1.20.1.1.3ColumnveModeread-onlymandatoryService Clock Recovery Mode
1.3.6.1.4.1.251.1.1.20.1.1.4ColumnvePriorityread-onlymandatorySet to high for normal CBR operation
1.3.6.1.4.1.251.1.1.20.1.1.5ColumnvePvcValidread-onlymandatoryIndicates if valid PVC exists for Link
1.3.6.1.4.1.251.1.1.20.1.1.6ColumnveDstSlotread-onlymandatoryDestination Slot for PVC
1.3.6.1.4.1.251.1.1.20.1.1.7ColumnveDstLinkread-onlymandatoryDestination Link for PVC
1.3.6.1.4.1.251.1.1.20.1.1.8ColumnveDstVpiread-onlymandatoryDestination VPI for PVC
1.3.6.1.4.1.251.1.1.20.1.1.9ColumnveDstVciread-onlymandatoryDestination VCI for PVC
1.3.6.1.4.1.251.1.1.20.1.1.10ColumnveCDVread-writemandatoryCell Delay Variation Tolerance
1.3.6.1.4.1.251.1.1.20.1.1.11ColumnveCDVMaxread-writemandatoryCell Delay Variation Tolerance
1.3.6.1.4.1.251.1.1.20.1.1.24ColumnveMulticastread-onlymandatoryIs link part of multicast tree
1.3.6.1.4.1.251.1.1.20.1.1.25ColumnveXhIntread-onlymandatoryXH Interface for Link
1.3.6.1.4.1.251.1.1.20.2TableveStatTablenot-accessiblemandatorystatus information about the dv2VE.
1.3.6.1.4.1.251.1.1.20.2.1RowveStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.20.2.1.1ColumnveStatPortNoread-onlymandatoryLink Number for Table Entry
1.3.6.1.4.1.251.1.1.20.2.1.2ColumnveStatResetread-writemandatoryClear Statistics for Link
1.3.6.1.4.1.251.1.1.20.2.1.3ColumnveStatTxStateread-onlymandatoryIndicates if data is being received and segmented
1.3.6.1.4.1.251.1.1.20.2.1.4ColumnveStatRxStateread-onlymandatoryIndicates if data being reassembled and transmitted
1.3.6.1.4.1.251.1.1.20.2.1.5ColumnveTxCntread-onlymandatoryCount of Cells transmitted from switch fabric
1.3.6.1.4.1.251.1.1.20.2.1.6ColumnveRxCntread-onlymandatoryCount of Cells received into switch fabric
1.3.6.1.4.1.251.1.1.20.2.1.7ColumnveOflCntread-onlymandatoryCount of 1S intervals during which RX FIFO overflowed or underflowed
1.3.6.1.4.1.251.1.1.20.2.1.8ColumnveUflCntread-onlymandatoryCount of 1S intervals during which RX FIFO underflowed
1.3.6.1.4.1.251.1.1.20.2.1.9ColumnveDisCntread-onlymandatoryCount of 1S intervals during which cells were discarded
1.3.6.1.4.1.251.1.1.20.2.1.10ColumnveInvCntread-onlymandatoryCount of 1S intervals during which cells were invented
1.3.6.1.4.1.251.1.1.20.2.1.11ColumnveResCntread-onlymandatoryCount of 1S intervals during which AAL1 resync occurred
1.3.6.1.4.1.251.1.1.20.2.1.12ColumnveFifoLvlCntread-onlymandatoryNumber of Cells currently in FIFO
1.3.6.1.4.1.251.1.1.21Nodedv2SystemClocks
1.3.6.1.4.1.251.1.1.21.1ScalarautoRevertread-writemandatoryAutomatic Revert after Timing Source Recovery
1.3.6.1.4.1.251.1.1.21.2ScalarrevertTimerread-writemandatoryRevert Timer in Seconds
1.3.6.1.4.1.251.1.1.21.3ScalarforceRevertread-writemandatoryForce Immediate Revert
1.3.6.1.4.1.251.1.1.21.4ScalarforceSecondaryread-writemandatoryForce Secondary Source Timing
1.3.6.1.4.1.251.1.1.21.5ScalaralarmStatusread-onlymandatoryTiming Alarm Status
1.3.6.1.4.1.251.1.1.21.6ScalarinServiceread-onlymandatoryCard in Service
1.3.6.1.4.1.251.1.1.21.7TableprimaryClockTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.7.1RowprimaryEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.7.1.1ColumnpIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.7.1.2ColumnpValidSourceread-onlymandatoryValid Timing Source
1.3.6.1.4.1.251.1.1.21.7.1.3ColumnpOnOffLineread-writemandatoryOn / Off line Toggle
1.3.6.1.4.1.251.1.1.21.7.1.4ColumnpSlotNumberread-writemandatoryPrimary Source Slot Number
1.3.6.1.4.1.251.1.1.21.7.1.5ColumnpSysRefSelectread-writemandatorySystem Reference Select
1.3.6.1.4.1.251.1.1.21.7.1.6ColumnpActiveTimingSourceread-onlymandatoryActive Timing Reference
1.3.6.1.4.1.251.1.1.21.7.1.7ColumnpInputLineOkread-onlymandatoryInput Line OK
1.3.6.1.4.1.251.1.1.21.7.1.8ColumnpSysRefTimingOkread-onlymandatorySystem Reference Timing OK
1.3.6.1.4.1.251.1.1.21.8TablesecondaryClockTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.8.1RowsecondaryEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.8.1.1ColumnsIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.8.1.2ColumnsValidSourceread-onlymandatoryValid Timing Source
1.3.6.1.4.1.251.1.1.21.8.1.3ColumnsOnOffLineread-writemandatoryOn / Off line Toggle
1.3.6.1.4.1.251.1.1.21.8.1.4ColumnsSlotNumberread-writemandatorySecondary Source Slot Number
1.3.6.1.4.1.251.1.1.21.8.1.5ColumnsSysRefSelectread-writemandatorySystem Reference Select
1.3.6.1.4.1.251.1.1.21.8.1.6ColumnsActiveTimingSourceread-onlymandatoryActive Timing Reference
1.3.6.1.4.1.251.1.1.21.8.1.7ColumnsInputLineOkread-onlymandatoryInput Line OK
1.3.6.1.4.1.251.1.1.21.8.1.8ColumnsSysRefTimingOkread-onlymandatorySystem Reference Timing OK
1.3.6.1.4.1.251.1.1.21.9Scalarstr3Configuredread-onlymandatoryCAT Card present
1.3.6.1.4.1.251.1.1.21.10TablepCATcontrolTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.10.1RowpCATcontrolEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.10.1.1ColumnpccIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.10.1.2Columnpccatlimtyperead-writemandatoryType of CAT LIM
1.3.6.1.4.1.251.1.1.21.10.1.3Columnpccatsendcoderead-writemandatorySend code to NTM LIM
1.3.6.1.4.1.251.1.1.21.10.1.4Columnpccatactivateread-writemandatoryActivate NTM Code
1.3.6.1.4.1.251.1.1.21.10.1.5Columnpccatsendconfigread-writemandatorySend Configuration to NTM LIM
1.3.6.1.4.1.251.1.1.21.10.1.6Columnpccatbytestransferredread-onlymandatoryCode bytes transferred to NTM LIM
1.3.6.1.4.1.251.1.1.21.10.1.7Columnpccatfilexferstatread-onlymandatoryFile transfer status as reported by Slot 0
1.3.6.1.4.1.251.1.1.21.10.1.8Columnpcatforcesecextread-writemandatoryForce the secondary external
1.3.6.1.4.1.251.1.1.21.10.1.9Columnpcatforcesecstr3read-writemandatoryForce the secondary stratum 3
1.3.6.1.4.1.251.1.1.21.10.1.10Columnpcatcommandread-onlymandatoryInternal Use
1.3.6.1.4.1.251.1.1.21.10.1.11Columnpcatplaceholder1read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.10.1.12Columnpcatplaceholder2read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.10.1.13Columnpcconofflineread-writemandatoryPut NTM LIM on or offline
1.3.6.1.4.1.251.1.1.21.11TablesCATcontrolTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.11.1RowsCATcontrolEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.11.1.1ColumnsccIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.11.1.2Columnsccatlimtyperead-writemandatoryType of NTM LIM
1.3.6.1.4.1.251.1.1.21.11.1.3Columnsccatsendcoderead-writemandatoryDownload code to NTM LIM
1.3.6.1.4.1.251.1.1.21.11.1.4Columnsccatactivateread-writemandatoryActivate NTM Code
1.3.6.1.4.1.251.1.1.21.11.1.5Columnsccatsendconfigread-writemandatoryDownload Configuration to NTM LIM
1.3.6.1.4.1.251.1.1.21.11.1.6Columnsccatbytestransferredread-onlymandatoryCode bytes transferred to NTM LIM
1.3.6.1.4.1.251.1.1.21.11.1.7Columnsccatfilexferstatread-onlymandatoryFile transfer status as reported by Slot 0
1.3.6.1.4.1.251.1.1.21.11.1.8Columnscatcommandread-onlymandatoryInternal Use
1.3.6.1.4.1.251.1.1.21.11.1.9Columnscatplaceholder1read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.11.1.10Columnscatplaceholder2read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.11.1.11Columnscconofflineread-writemandatoryPut NTM LIM on or offline
1.3.6.1.4.1.251.1.1.21.12TablepCATstatusTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.12.1RowpCATstatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.12.1.1ColumnpscIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.12.1.2Columnpscatlimtyperead-onlymandatoryType of NTM LIM detected
1.3.6.1.4.1.251.1.1.21.12.1.3ColumnpsCATFFrevisionread-onlymandatoryNTM LIM Code Revision
1.3.6.1.4.1.251.1.1.21.12.1.4ColumnpsCATBootrevisionread-onlymandatoryNTM LIM Boot Revision
1.3.6.1.4.1.251.1.1.21.12.1.5Columnpscatfilestatusread-onlymandatoryFlash file status
1.3.6.1.4.1.251.1.1.21.12.1.6ColumnpsCATfilerevisionread-onlymandatoryNTM LIM file Revision
1.3.6.1.4.1.251.1.1.21.12.1.7ColumnpsCATHWrevisionread-onlymandatoryNTM LIM Hardware Revision
1.3.6.1.4.1.251.1.1.21.12.1.8Columnpscatmoderead-onlymandatoryOperating Mode of NTM LIM
1.3.6.1.4.1.251.1.1.21.12.1.9Columnpscaterrorcoderead-onlymandatoryNTM LIM Error Code
1.3.6.1.4.1.251.1.1.21.12.1.10Columnpscatplaceholder1read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.12.1.11Columnpscatplaceholder2read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.13TablesCATstatusTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.13.1RowsCATstatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.13.1.1ColumnsscIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.13.1.2Columnsscatlimtyperead-onlymandatoryType of NTM LIM
1.3.6.1.4.1.251.1.1.21.13.1.3ColumnssCATFFrevisionread-onlymandatoryNTM LIM Code Revision
1.3.6.1.4.1.251.1.1.21.13.1.4ColumnssCATBootrevisionread-onlymandatoryNTM LIM Boot Revision
1.3.6.1.4.1.251.1.1.21.13.1.5Columnsscatfilestatusread-onlymandatoryFlash file status
1.3.6.1.4.1.251.1.1.21.13.1.6ColumnssCATfilerevisionread-onlymandatoryNTM LIM file Revision
1.3.6.1.4.1.251.1.1.21.13.1.7ColumnssCATHWrevisionread-onlymandatoryNTM LIM Hardware Revision
1.3.6.1.4.1.251.1.1.21.13.1.8Columnsscatmoderead-onlymandatoryOperating mode of NTM LIM
1.3.6.1.4.1.251.1.1.21.13.1.9Columnsscaterrorcoderead-onlymandatoryNTM LIM Error Code
1.3.6.1.4.1.251.1.1.21.13.1.10Columnsscatplaceholder1read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.13.1.11Columnsscatplaceholder2read-onlymandatoryPlaceholder for future MIB changes
1.3.6.1.4.1.251.1.1.21.14TablepCATStratum3ConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.14.1RowpCATStratum3ConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.14.1.1Columnps3cIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.14.1.2Columnpcatstr3listenerread-writemandatoryConfigures Stratum 3 Reference
1.3.6.1.4.1.251.1.1.21.14.1.3Columnpcatstr3oscillatorread-writemandatoryConfigures Stratum 3 Mode
1.3.6.1.4.1.251.1.1.21.14.1.4Columnpcatstr3forcesecondaryread-writemandatoryDisables Stratum 3 Driver on Primary NTM LIM only
1.3.6.1.4.1.251.1.1.21.14.1.5Columnpcatstr3reconfigureread-writemandatoryRe-configure Primary Stratum 3
1.3.6.1.4.1.251.1.1.21.15TablesCATStratum3ConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.15.1RowsCATStratum3ConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.15.1.1Columnss3cIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.15.1.2Columnscatstr3listenerread-writemandatoryConfigures Stratum 3 Reference
1.3.6.1.4.1.251.1.1.21.15.1.3Columnscatstr3oscillatorread-writemandatoryConfigures Stratum 3 Mode
1.3.6.1.4.1.251.1.1.21.15.1.4Columnscatstr3reconfigureread-writemandatoryRe-configure Secondary Stratum 3
1.3.6.1.4.1.251.1.1.21.16TablepCATStratum3StatusTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.16.1RowpCATStratum3StatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.16.1.1Columnps3sIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.16.1.2Columnpcatstr3listenerstatusread-onlymandatoryWhat the Stratum 3 is referencing to
1.3.6.1.4.1.251.1.1.21.16.1.3Columnpcatstr3driverstatusread-onlymandatoryWhat the Stratum 3 output is driving
1.3.6.1.4.1.251.1.1.21.16.1.4Columnpcatstr3oscstatusread-onlymandatoryStratum 3 oscillator status
1.3.6.1.4.1.251.1.1.21.17TablesCATStratum3StatusTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.17.1RowsCATStratum3StatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.17.1.1Columnss3sIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.17.1.2Columnscatstr3listenerstatusread-onlymandatoryWhat the Stratum 3 Listener is referencing
1.3.6.1.4.1.251.1.1.21.17.1.3Columnscatstr3driverstatusread-onlymandatoryWhat the Stratum 3 output is driving
1.3.6.1.4.1.251.1.1.21.17.1.4Columnscatstr3oscstatusread-onlymandatoryStratum 3 oscillator status
1.3.6.1.4.1.251.1.1.21.18TablepCATBitsConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.18.1RowpCATBitsConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.18.1.1ColumnpbcIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.18.1.2Columnpbcds1V2TxLineLnread-writemandatorySelect transmit line length
1.3.6.1.4.1.251.1.1.21.18.1.3Columnpbcplaceholder1read-writemandatoryFuture Use
1.3.6.1.4.1.251.1.1.21.18.1.4ColumnpbcV2FRMRModeread-writemandatoryDS1 Framing options.
1.3.6.1.4.1.251.1.1.21.18.1.5Columnpbcds1V2Codingread-writemandatoryT1 Line Code
1.3.6.1.4.1.251.1.1.21.18.1.6ColumnpbcV2Lbread-writemandatoryLoopback Selection DS1
1.3.6.1.4.1.251.1.1.21.18.1.7Columnpbcclrperfread-writemandatoryClear the Performance Counters
1.3.6.1.4.1.251.1.1.21.18.1.9Columnpbcreconfigureread-writemandatoryRe-configure Primary External
1.3.6.1.4.1.251.1.1.21.19TablesCATBitsConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.19.1RowsCATBitsConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.19.1.1ColumnsbcIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.19.1.2Columnsbcds1V2TxLineLnread-writemandatorySelect transmit line length
1.3.6.1.4.1.251.1.1.21.19.1.3Columnsbcplaceholder1read-writemandatoryFuture Use
1.3.6.1.4.1.251.1.1.21.19.1.4ColumnsbcV2FRMRModeread-writemandatoryDS1 Framing options.
1.3.6.1.4.1.251.1.1.21.19.1.5Columnsbcds1V2Codingread-writemandatoryT1 Line Coding
1.3.6.1.4.1.251.1.1.21.19.1.6ColumnsbcV2Lbread-writemandatoryLoopback Selection
1.3.6.1.4.1.251.1.1.21.19.1.7Columnsbcclrperfread-writemandatoryClear the Performance Counters
1.3.6.1.4.1.251.1.1.21.19.1.8Columnsbcreconfigureread-writemandatoryRe-configure Secondary External
1.3.6.1.4.1.251.1.1.21.20TablepCATBitsStatusTablenot-accessiblemandatoryDs1/E1 Bits Status Table
1.3.6.1.4.1.251.1.1.21.20.1RowpCATBitsStatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.20.1.1ColumnpbsIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.20.1.2Columnpbslineokread-onlymandatoryIs the line OK
1.3.6.1.4.1.251.1.1.21.20.1.3ColumnpbsV2RxAISread-onlymandatoryReceive DS1 AIS(Blue)Alarm status.
1.3.6.1.4.1.251.1.1.21.20.1.4ColumnpbsV2RxLOSread-onlymandatoryReceive DS1 LOS status.
1.3.6.1.4.1.251.1.1.21.20.1.5ColumnpbsV2RxOOFread-onlymandatoryReceive DS1 OOF status.
1.3.6.1.4.1.251.1.1.21.20.1.6ColumnpbsV2RxBERread-onlymandatoryReceive DS1 BER status.
1.3.6.1.4.1.251.1.1.21.20.1.7ColumnpbsV2RxOOFCntread-onlymandatoryReceive DS1 OOF count.
1.3.6.1.4.1.251.1.1.21.20.1.8ColumnpbsV2RxBERCntread-onlymandatoryReceive DS1 BEE count.
1.3.6.1.4.1.251.1.1.21.20.1.9ColumnpbsV2RxLOSCntread-onlymandatoryReceive DS1 LOS count.
1.3.6.1.4.1.251.1.1.21.20.1.10ColumnpbsV2LCVCntread-onlymandatoryReceive DS1 LCV count.
1.3.6.1.4.1.251.1.1.21.21TablesCATBitsStatusTablenot-accessiblemandatoryDs1/E1 Bits Status Table
1.3.6.1.4.1.251.1.1.21.21.1RowsCATBitsStatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.21.1.1ColumnsbsIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.21.1.2Columnsbslineokread-onlymandatoryIs the line OK
1.3.6.1.4.1.251.1.1.21.21.1.3ColumnsbsV2RxAISread-onlymandatoryReceive DS1 AIS(Blue)Alarm status.
1.3.6.1.4.1.251.1.1.21.21.1.4ColumnsbsV2RxLOSread-onlymandatoryReceive DS1 LOS status.
1.3.6.1.4.1.251.1.1.21.21.1.5ColumnsbsV2RxOOFread-onlymandatoryReceive DS1 OOF status.
1.3.6.1.4.1.251.1.1.21.21.1.6ColumnsbsV2RxBERread-onlymandatoryReceive DS1 BER status.
1.3.6.1.4.1.251.1.1.21.21.1.7ColumnsbsV2RxOOFCntread-onlymandatoryReceive DS1 OOF Counts.
1.3.6.1.4.1.251.1.1.21.21.1.8ColumnsbsV2RxBERCntread-onlymandatoryReceive DS1 BEE Counts.
1.3.6.1.4.1.251.1.1.21.21.1.9ColumnsbsV2RxLOSCntread-onlymandatoryReceive DS1/E1 LOS Counts.
1.3.6.1.4.1.251.1.1.21.21.1.10ColumnsbsV2LCVCntread-onlymandatoryReceive DS1 AIS Counts.
1.3.6.1.4.1.251.1.1.21.22TablepCATDerConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.22.1RowpCATDerConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.22.1.1ColumnpdcIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.22.1.2Columnpdcds1V2TxLineLnread-writemandatorySelect transmit line length
1.3.6.1.4.1.251.1.1.21.22.1.3Columnpdcplaceholder1read-writemandatoryFuture Use
1.3.6.1.4.1.251.1.1.21.22.1.4ColumnpdcV2FRMRModeread-writemandatoryDS1 Framing options.
1.3.6.1.4.1.251.1.1.21.22.1.5Columnpdcds1V2Codingread-writemandatoryLine Code
1.3.6.1.4.1.251.1.1.21.22.1.6ColumnpdcV2Lbread-writemandatoryLoopback Selection
1.3.6.1.4.1.251.1.1.21.22.1.7Columnpdcclrperfread-writemandatoryClear the performance counters
1.3.6.1.4.1.251.1.1.21.22.1.8Columnpdcreconfigureread-writemandatoryRe-configure Primary Line
1.3.6.1.4.1.251.1.1.21.23TablesCATDerConfigTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.23.1RowsCATDerConfigEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.23.1.1ColumnsdcIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.23.1.2Columnsdcds1V2TxLineLnread-writemandatorySelect transmit line length
1.3.6.1.4.1.251.1.1.21.23.1.3Columnsdcplaceholder1read-writemandatoryFuture Use
1.3.6.1.4.1.251.1.1.21.23.1.4ColumnsdcV2FRMRModeread-writemandatoryDS1 Framing options.
1.3.6.1.4.1.251.1.1.21.23.1.5Columnsdcds1V2Codingread-writemandatoryLine Coding
1.3.6.1.4.1.251.1.1.21.23.1.6ColumnsdcV2Lbread-writemandatoryLoopback Selection DS1
1.3.6.1.4.1.251.1.1.21.23.1.7Columnsdcclrperfread-writemandatoryClear the Performance Counters
1.3.6.1.4.1.251.1.1.21.23.1.8Columnsdcreconfigureread-writemandatoryRe-configure Secondary Line
1.3.6.1.4.1.251.1.1.21.24TablepCATDerStatusTablenot-accessiblemandatoryDs1/E1 Derived Status Table
1.3.6.1.4.1.251.1.1.21.24.1RowpCATDerStatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.24.1.1ColumnpdsIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.24.1.2Columnpdslineokread-onlymandatoryIs the line OK
1.3.6.1.4.1.251.1.1.21.24.1.3ColumnpdsV2TxReferenceread-onlymandatoryTransmit Reference Status
1.3.6.1.4.1.251.1.1.21.24.1.4ColumnpdsV2RxAISread-onlymandatoryReceive DS1 AIS(Blue)Alarm status.
1.3.6.1.4.1.251.1.1.21.24.1.5ColumnpdsV2RxLOSread-onlymandatoryReceive DS1 LOS status.
1.3.6.1.4.1.251.1.1.21.24.1.6ColumnpdsV2RxOOFread-onlymandatoryReceive DS1 OOF status.
1.3.6.1.4.1.251.1.1.21.24.1.7ColumnpdsV2RxBERread-onlymandatoryReceive DS1 BER status.
1.3.6.1.4.1.251.1.1.21.24.1.8ColumnpdsV2RxOOFCntread-onlymandatoryReceive DS1 OOF count.
1.3.6.1.4.1.251.1.1.21.24.1.9ColumnpdsV2RxBERCntread-onlymandatoryReceive DS1 BEE count.
1.3.6.1.4.1.251.1.1.21.24.1.10ColumnpdsV2RxLOSCntread-onlymandatoryReceive DS1 LOS count.
1.3.6.1.4.1.251.1.1.21.24.1.11ColumnpdsV2LCVCntread-onlymandatoryReceive DS1 AIS count.
1.3.6.1.4.1.251.1.1.21.25TablesCATDerStatusTablenot-accessiblemandatoryDs1/E1 Derived Status Table
1.3.6.1.4.1.251.1.1.21.25.1RowsCATDerStatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.21.25.1.1ColumnsdsIndexread-onlymandatoryEntry Index
1.3.6.1.4.1.251.1.1.21.25.1.2Columnsdslineokread-onlymandatoryIs the line OK
1.3.6.1.4.1.251.1.1.21.25.1.3ColumnsdsV2TxReferenceread-onlymandatoryTransmit Reference Status
1.3.6.1.4.1.251.1.1.21.25.1.4ColumnsdsV2RxAISread-onlymandatoryReceive DS1 AIS(Blue)Alarm status.
1.3.6.1.4.1.251.1.1.21.25.1.5ColumnsdsV2RxLOSread-onlymandatoryReceive DS1 LOS status.
1.3.6.1.4.1.251.1.1.21.25.1.6ColumnsdsV2RxOOFread-onlymandatoryReceive DS1 OOF status.
1.3.6.1.4.1.251.1.1.21.25.1.7ColumnsdsV2RxBERread-onlymandatoryReceive DS1 BER status.
1.3.6.1.4.1.251.1.1.21.25.1.8ColumnsdsV2RxOOFCntread-onlymandatoryReceive DS1 OOF count.
1.3.6.1.4.1.251.1.1.21.25.1.9ColumnsdsV2RxBERCntread-onlymandatoryReceive DS1 BEE count.
1.3.6.1.4.1.251.1.1.21.25.1.10ColumnsdsV2RxLOSCntread-onlymandatoryReceive DS1 LOS count.
1.3.6.1.4.1.251.1.1.21.25.1.11ColumnsdsV2LCVCntread-onlymandatoryReceive DS1 AIS count.
1.3.6.1.4.1.251.1.1.21.26ScalarsysClkAlarmErrread-onlymandatoryDefines the error type for the current clock alarm
1.3.6.1.4.1.251.1.1.22NodemjlimSlipLine
1.3.6.1.4.1.251.1.1.22Nodereset040This is sent when a the master processor is reset by operator
1.3.6.1.4.1.251.1.1.22.1ScalarjpegSlipIpread-writemandatoryIP address of SLIP line.
1.3.6.1.4.1.251.1.1.22.2ScalarjpegSlipMaskread-writemandatoryMask for SLIP line.
1.3.6.1.4.1.251.1.1.22.3ScalarjpegSlipRemoteIpread-writemandatoryIP address of remote end of SLIP line.
1.3.6.1.4.1.251.1.1.22.4ScalarjpegSlipSpeedread-writemandatoryBaud rate of SLIP serial line.
1.3.6.1.4.1.251.1.1.23NodebadPasswordThis is sent when a user enters a bad password
1.3.6.1.4.1.251.1.1.23NodemjlimSystem
1.3.6.1.4.1.251.1.1.23.1ScalarlimSysStateread-onlymandatoryM-JPEG LIM System State
1.3.6.1.4.1.251.1.1.23.2ScalarlimSysFaultread-onlymandatoryM-JPEG LIM Hardware Fault - front panel lamp
1.3.6.1.4.1.251.1.1.23.3ScalarlimSysCompErrread-onlymandatoryM-JPEG LIM Compression Error - front panel lamp
1.3.6.1.4.1.251.1.1.23.4ScalarlimSysDecompErrread-onlymandatoryM-JPEG LIM Decompression Error - front panel lamp
1.3.6.1.4.1.251.1.1.23.5ScalarlimSysVideoInread-onlymandatoryM-JPEG LIM Video Input Present - front panel lamp
1.3.6.1.4.1.251.1.1.23.6ScalarlimSysVideoOutread-onlymandatoryM-JPEG LIM Video Output Active - front panel lamp
1.3.6.1.4.1.251.1.1.23.30ScalarlimSysStartModeread-writemandatoryM-JPEG LIM Default Startup mode
1.3.6.1.4.1.251.1.1.24NodevidInCfg
1.3.6.1.4.1.251.1.1.24.1ScalarvidInJpegread-writemandatoryM-JPEG LIM Video Input JPEG mode
1.3.6.1.4.1.251.1.1.24.2ScalarvidInRateread-writemandatoryM-JPEG LIM Video Input Channel Bit Rate
1.3.6.1.4.1.251.1.1.24.3ScalarvidInProvModeread-writemandatoryM-JPEG LIM Video Input Provisioning Mode
1.3.6.1.4.1.251.1.1.24.4ScalarvidInFrameRateread-writemandatoryM-JPEG LIM Video Input Frame Rate
1.3.6.1.4.1.251.1.1.24.5ScalarvidInWindowSizeread-writemandatoryM-JPEG LIM Video Input Window size
1.3.6.1.4.1.251.1.1.24.6ScalarvidInQuanFactorread-writemandatoryM-JPEG LIM Video Input Quantization factor
1.3.6.1.4.1.251.1.1.24.7ScalarvidInTransModeread-writemandatoryM-JPEG LIM Video Input Transmit Mode
1.3.6.1.4.1.251.1.1.24.8ScalarvidInStandread-writemandatoryM-JPEG LIM Video Input Standard
1.3.6.1.4.1.251.1.1.24.9ScalarvidInVcrModeread-writemandatoryM-JPEG LIM Video Input VCR mode
1.3.6.1.4.1.251.1.1.24.10ScalarvidInAnLpbkread-writemandatoryM-JPEG LIM Video Input Analog Loopback
1.3.6.1.4.1.251.1.1.24.11ScalarvidInTestread-writemandatoryM-JPEG LIM Video Input Test Pattern
1.3.6.1.4.1.251.1.1.25NodevidOutCfg
1.3.6.1.4.1.251.1.1.25.1ScalarvidOutJpegread-writemandatoryM-JPEG LIM Video Output JPEG Mode
1.3.6.1.4.1.251.1.1.25.2ScalarvidOutStandread-writemandatoryM-JPEG LIM Video Output Standard
1.3.6.1.4.1.251.1.1.25.3ScalarvidOutSourceread-writemandatoryM-JPEG LIM Video Output Timing Source
1.3.6.1.4.1.251.1.1.25.4ScalarvidOutUnLpbread-writemandatoryM-JPEG LIM Video Output Uncompressed Loopback
1.3.6.1.4.1.251.1.1.25.5ScalarvidOutIdleSrcread-writemandatoryM-JPEG LIM Video Output Idle Source
1.3.6.1.4.1.251.1.1.25.6ScalarvidOutChnlLpbkread-writemandatoryM-JPEG LIM Video Output Channel Loopback
1.3.6.1.4.1.251.1.1.26NodebillingRecFailCould not create billing record
1.3.6.1.4.1.251.1.1.26NodevidInSta
1.3.6.1.4.1.251.1.1.26.1ScalarvidInStateread-onlymandatoryM-JPEG LIM Video Input State
1.3.6.1.4.1.251.1.1.26.2ScalarvidInPresread-onlymandatoryM-JPEG LIM Video Input Present Indicator
1.3.6.1.4.1.251.1.1.26.3ScalarvidInCurQFactorread-onlymandatoryM-JPEG LIM Video Input Current Quality Factor
1.3.6.1.4.1.251.1.1.26.4ScalarvidInCurFrameRateread-onlymandatoryM-JPEG LIM Video Input Current Frame Rate
1.3.6.1.4.1.251.1.1.26.5ScalarvidInAvgBitRateread-onlymandatoryM-JPEG LIM Video Input Average Bitrate (Mpbs)
1.3.6.1.4.1.251.1.1.26.6ScalarvidInPeakBitRateread-onlymandatoryM-JPEG LIM Video Input Peak Bitrate (Mbps)
1.3.6.1.4.1.251.1.1.26.7ScalarvidInSubSampleread-onlymandatoryM-JPEG LIM Video Input Field Subsample Status
1.3.6.1.4.1.251.1.1.26.8ScalarvidInCompCntread-onlymandatoryM-JPEG LIM Video Input Compressed Packet Count
1.3.6.1.4.1.251.1.1.26.9ScalarvidInSkipCntread-onlymandatoryM-JPEG LIM Video Input Skipped Packet Count
1.3.6.1.4.1.251.1.1.26.10ScalarvidInBuffOvfread-onlymandatoryM-JPEG LIM Video Input Buffer Controller Overflow Count
1.3.6.1.4.1.251.1.1.26.11ScalarvidInImageErrread-onlymandatoryM-JPEG LIM Video Input JPEG Chip FIFO Overflow
1.3.6.1.4.1.251.1.1.26.12ScalarvidInFldSynErrread-onlymandatoryM-JPEG LIM Video Input Field Synchronization Errors
1.3.6.1.4.1.251.1.1.26.13ScalarvidInCompErrread-onlymandatoryM-JPEG LIM Video Input Compression Errors
1.3.6.1.4.1.251.1.1.26.14ScalarvidInBufLevelread-onlymandatoryM-JPEG LIM Video Input Buffer Fill Level (%)
1.3.6.1.4.1.251.1.1.26.15ScalarvidInFailReasonread-onlymandatoryM-JPEG LIM Video Input Fail Reason
1.3.6.1.4.1.251.1.1.27NodeclockAlarmChange in system clock alarm state: declare or clear minor/major alarms, describe error and location, includes primary/secondary clock locations and the active…
1.3.6.1.4.1.251.1.1.27NodevidOutSta
1.3.6.1.4.1.251.1.1.27.1ScalarvidOutStateread-onlymandatoryM-JPEG LIM Video Output state
1.3.6.1.4.1.251.1.1.27.2ScalarvidOutRateread-onlymandatoryM-JPEG LIM Video Output Bitrate (Mbps)
1.3.6.1.4.1.251.1.1.27.3ScalarvidOutFrameRateread-onlymandatoryM-JPEG LIM Video Output Frame Rate
1.3.6.1.4.1.251.1.1.27.4ScalarvidOutWindowWidthread-onlymandatoryM-JPEG LIM Video Output Window Width
1.3.6.1.4.1.251.1.1.27.5ScalarvidOutWindowHeightread-onlymandatoryM-JPEG LIM Video Output Window Height
1.3.6.1.4.1.251.1.1.27.6ScalarvidOutChnlLockread-onlymandatoryM-JPEG LIM Video Output Channel Lock Indicator
1.3.6.1.4.1.251.1.1.27.7ScalarvidOutPacketsread-onlymandatoryM-JPEG LIM Video Output Packets Received Count
1.3.6.1.4.1.251.1.1.27.8ScalarvidOutPlayedread-onlymandatoryM-JPEG LIM Video Output Packets Played Count
1.3.6.1.4.1.251.1.1.27.9ScalarvidOutSkippedread-onlymandatoryM-JPEG LIM Video Output Skipped Packet Count
1.3.6.1.4.1.251.1.1.27.10ScalarvidOutChnlErrread-onlymandatoryM-JPEG LIM Video Output Channel Error Count
1.3.6.1.4.1.251.1.1.27.11ScalarvidOutBuffOvfread-onlymandatoryM-JPEG LIM Video Output Buffer Controller Overflow Count
1.3.6.1.4.1.251.1.1.27.12ScalarvidOutImageErrread-onlymandatoryM-JPEG LIM Video Output JPEG Chip Error Count
1.3.6.1.4.1.251.1.1.27.13ScalarvidOutSeqnoErrread-onlymandatoryM-JPEG LIM Video Output Packet Sequence Number Error Count
1.3.6.1.4.1.251.1.1.27.14ScalarvidOutCurrQFactorread-onlymandatoryM-JPEG LIM Video Output Current JPEG Quantization Factor
1.3.6.1.4.1.251.1.1.27.15ScalarvidOutStdStatread-onlymandatoryM-JPEG LIM Video Output Standard Status
1.3.6.1.4.1.251.1.1.27.16ScalarvidOutBuffLevelread-onlymandatoryM-JPEG LIM Video Output Buffer Fill Level (%)
1.3.6.1.4.1.251.1.1.27.17ScalarvidOutPktsInBuffread-onlymandatoryM-JPEG LIM Video Output Packets in Buffer
1.3.6.1.4.1.251.1.1.27.18ScalarvidOutFailReasonread-onlymandatoryM-JPEG LIM Video Output Fail Reason
1.3.6.1.4.1.251.1.1.27.19ScalarvidOutSrcStsread-onlymandatoryM-JPEG LIM Video Output Timing Source Status
1.3.6.1.4.1.251.1.1.28NodeaudInCfg
1.3.6.1.4.1.251.1.1.28NodespvcInitCall successfully established
1.3.6.1.4.1.251.1.1.28.1ScalaraudInLoopBackread-writemandatoryM-JPEG LIM Audio Input LoopBack Mode
1.3.6.1.4.1.251.1.1.29NodeaudOutCfg
1.3.6.1.4.1.251.1.1.29NodespvcFailCall attempt failed
1.3.6.1.4.1.251.1.1.29.1ScalaraudOutMuteread-writemandatoryM-JPEG LIM Audio Output Mute Control
1.3.6.1.4.1.251.1.1.29.2ScalaraudOutDigLpbkread-writemandatoryM-JPEG LIM Audio Digital Loopback
1.3.6.1.4.1.251.1.1.30NodeaudInSta
1.3.6.1.4.1.251.1.1.30NodespvcCallClrCall cleared after established
1.3.6.1.4.1.251.1.1.31NodeaudOutSta
1.3.6.1.4.1.251.1.1.31NodespvcCallResetCall reset after established
1.3.6.1.4.1.251.1.1.31.1ScalaraudOutLockread-onlymandatoryM-JPEG LIM Audio Output Channel Lock Indicator
1.3.6.1.4.1.251.1.1.31.2ScalaraudOutMuteStatread-onlymandatoryM-JPEG LIM Audio Output Mute Status
1.3.6.1.4.1.251.1.1.32NodedataCfg
1.3.6.1.4.1.251.1.1.32.1ScalardataIpread-writemandatoryIP address of Data Channel.
1.3.6.1.4.1.251.1.1.32.2ScalardataMaskread-writemandatoryNetwork Mask for Data Channel.
1.3.6.1.4.1.251.1.1.32.3ScalardataRemoteIpread-writemandatoryIP address of remote end of Data Channel.
1.3.6.1.4.1.251.1.1.33NodedataSta
1.3.6.1.4.1.251.1.1.33NodespvcRetryExceededCall attempts exceeded retry limit
1.3.6.1.4.1.251.1.1.34NodemjlimControl
1.3.6.1.4.1.251.1.1.34.1ScalarsendFileSelread-writemandatoryFile to send
1.3.6.1.4.1.251.1.1.34.2ScalarjpegCurrentFileread-onlymandatoryFile being sent
1.3.6.1.4.1.251.1.1.34.3ScalarsendFileStatread-onlymandatoryStatus of file send
1.3.6.1.4.1.251.1.1.34.4ScalarsendFileBytesread-onlymandatoryBytes sent
1.3.6.1.4.1.251.1.1.34.20ScalarjpegResetread-writemandatoryHard/Soft Reset
1.3.6.1.4.1.251.1.1.34.21ScalarjpegSaveCfgread-writemandatorySave Configuration
1.3.6.1.4.1.251.1.1.34.22ScalarjpegLoadCfgread-writemandatoryLoad Configuration
1.3.6.1.4.1.251.1.1.34.40ScalarjpegSWRevread-onlymandatoryJPEG Code Revision
1.3.6.1.4.1.251.1.1.35Nodedv2PDH
1.3.6.1.4.1.251.1.1.35.1TablepdhPLCPTablenot-accessiblemandatoryThis table is used for PLCP configuration and status
1.3.6.1.4.1.251.1.1.35.1.1RowpdhPLCPEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.35.1.1.1ColumnpdhPLCPLinkNoread-onlymandatoryLink Number
1.3.6.1.4.1.251.1.1.35.1.1.2ColumnpdhPLCPLinkEnableread-writemandatoryEnable/Disable Link
1.3.6.1.4.1.251.1.1.35.1.1.3ColumnpdhPLCPLinkStatusAffectread-writemandatoryLink Status affect on receiving/transmitting
1.3.6.1.4.1.251.1.1.35.1.1.4ColumnpdhPLCPLinkStateread-onlymandatoryCurrent Link State
1.3.6.1.4.1.251.1.1.35.1.1.5ColumnpdhPLCPPhyModeread-writemandatoryThe physical framing for link
1.3.6.1.4.1.251.1.1.35.1.1.6ColumnpdhPLCPModeread-writemandatoryThe PLCP mode for link.
1.3.6.1.4.1.251.1.1.35.1.1.7ColumnpdhPLCPScramblerread-writemandatoryEnable/Disable scrambling
1.3.6.1.4.1.251.1.1.35.1.1.8ColumnpdhPLCP0x55read-writemandatoryEnable/Disable XORing HCS with 0x55
1.3.6.1.4.1.251.1.1.35.1.1.9ColumnpdhPLCPSmdsModeread-writemandatoryEnable/Disable SMDS mode
1.3.6.1.4.1.251.1.1.35.1.1.10ColumnpdhPLCPIdleCellread-writemandatoryIdle Cell Header Contents
1.3.6.1.4.1.251.1.1.35.1.1.11ColumnpdhPLCPLoopbackread-writemandatoryPLCP Loopback
1.3.6.1.4.1.251.1.1.35.1.1.12ColumnpdhPLCPClearread-writemandatoryClear PLCP counts
1.3.6.1.4.1.251.1.1.35.1.1.13ColumnpdhPLCPReconfigread-writemandatoryReconfigure link
1.3.6.1.4.1.251.1.1.35.1.1.14ColumnpdhPLCPLpbkTimeoutread-writemandatoryThis parameter is used to set the loopback timeout in minutes.
1.3.6.1.4.1.251.1.1.35.1.1.32ColumnpdhPLCPChipTyperead-onlymandatoryPDH Chip Type
1.3.6.1.4.1.251.1.1.35.1.1.33ColumnpdhPLCPTXclockread-onlymandatoryThe state of TX clock for this link.
1.3.6.1.4.1.251.1.1.35.1.1.34ColumnpdhPLCPRXclockread-onlymandatoryThe state of RX clock for this link.
1.3.6.1.4.1.251.1.1.35.1.1.35ColumnpdhPLCPTXCellsread-onlymandatoryThe transmit cells count for this link.
1.3.6.1.4.1.251.1.1.35.1.1.36ColumnpdhPLCPRXCellsread-onlymandatoryThe receive cells count for this link.
1.3.6.1.4.1.251.1.1.35.1.1.37ColumnpdhPLCPHCSErrsread-onlymandatoryThe header checksum error count for this link.
1.3.6.1.4.1.251.1.1.35.1.1.43ColumnpdhPLCPLOCDDefectread-onlymandatoryLoss of cell delineation Defect
1.3.6.1.4.1.251.1.1.35.1.1.44ColumnpdhPLCPYellowDefectread-onlymandatoryPLCP Yellow Defect
1.3.6.1.4.1.251.1.1.35.1.1.45ColumnpdhPLCPLOFDefectread-onlymandatoryPLCP Loss Of Frame Defect
1.3.6.1.4.1.251.1.1.35.1.1.49ColumnpdhPLCPLOCDAlarmread-onlymandatoryLoss of cell delineation Alarm
1.3.6.1.4.1.251.1.1.35.1.1.50ColumnpdhPLCPYellowAlarmread-onlymandatoryPLCP Yellow Alarm
1.3.6.1.4.1.251.1.1.35.1.1.51ColumnpdhPLCPLOFAlarmread-onlymandatoryPLCP Loss Of Frame Alarm
1.3.6.1.4.1.251.1.1.35.1.1.56ColumnpdhPLCPFrameErrsread-onlymandatoryNumber of PLCP frame errors
1.3.6.1.4.1.251.1.1.35.1.1.57ColumnpdhPLCPBIP8Errsread-onlymandatoryNumber of PLCP BIP-8 errors
1.3.6.1.4.1.251.1.1.35.1.1.58ColumnpdhPLCPFEBEErrsread-onlymandatoryNumber of PLCP FEBE errors
1.3.6.1.4.1.251.1.1.35.1.1.63ColumnpdhPLCPESread-onlymandatoryPLCP Errored Seconds
1.3.6.1.4.1.251.1.1.35.1.1.64ColumnpdhPLCPSESread-onlymandatoryPLCP Severely Errored Seconds
1.3.6.1.4.1.251.1.1.35.1.1.65ColumnpdhPLCPUASread-onlymandatoryPLCP Unavailable Seconds
1.3.6.1.4.1.251.1.1.35.1.1.66ColumnpdhPLCPFEESread-onlymandatoryPLCP Far End Errored Seconds
1.3.6.1.4.1.251.1.1.35.1.1.67ColumnpdhPLCPFESESread-onlymandatoryPLCP Far End Severely Errored Seconds
1.3.6.1.4.1.251.1.1.35.1.1.68ColumnpdhPLCPFEUASread-onlymandatoryPLCP Far End Unavailable Seconds
1.3.6.1.4.1.251.1.1.35.2TablepdhDS3Tablenot-accessiblemandatoryThis table is used for DS3 config/status supplied by the PLPP chip
1.3.6.1.4.1.251.1.1.35.2.1RowpdhDS3Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.35.2.1.1ColumnpdhDS3TableValidread-onlymandatoryIndicates if table is valid for configured LIM
1.3.6.1.4.1.251.1.1.35.2.1.2ColumnpdhDS3LinkNoread-onlymandatoryLink Number
1.3.6.1.4.1.251.1.1.35.2.1.3ColumnpdhDS3Framerread-writemandatoryDS3 framer mode
1.3.6.1.4.1.251.1.1.35.2.1.4ColumnpdhDS3TxAISread-writemandatoryTransmit AIS
1.3.6.1.4.1.251.1.1.35.2.1.5ColumnpdhDS3Clearread-writemandatoryClear Button for Counters
1.3.6.1.4.1.251.1.1.35.2.1.6ColumnpdhDS3Reconfigread-writemandatoryReconfigure link
1.3.6.1.4.1.251.1.1.35.2.1.26ColumnpdhDS3RxFrmFmtread-onlymandatoryReceive framing format
1.3.6.1.4.1.251.1.1.35.2.1.27ColumnpdhDS3RxIDLread-onlymandatoryReceive IDLE status
1.3.6.1.4.1.251.1.1.35.2.1.28ColumnpdhDS3FEACTxmtread-onlymandatoryCode that has been transmitted as a FEAC.
1.3.6.1.4.1.251.1.1.35.2.1.33ColumnpdhDS3Lcvsread-onlymandatoryDS3 Line Code Violation count
1.3.6.1.4.1.251.1.1.35.2.1.34ColumnpdhDS3FrameErrsread-onlymandatoryDS3 frame error count
1.3.6.1.4.1.251.1.1.35.2.1.35ColumnpdhDS3ParityErrsread-onlymandatoryDS3 parity error count
1.3.6.1.4.1.251.1.1.35.2.1.36ColumnpdhDS3CbitPrtyErrsread-onlymandatoryDS3 C-bit parity error count
1.3.6.1.4.1.251.1.1.35.2.1.37ColumnpdhDS3FEBEErrsread-onlymandatoryDS3 FEBE error count
1.3.6.1.4.1.251.1.1.35.2.1.43ColumnpdhDS3LOSDefectread-onlymandatoryDS3 Loss of Signal Defect
1.3.6.1.4.1.251.1.1.35.2.1.44ColumnpdhDS3OOFDefectread-onlymandatoryDS3 Out of Frame Defect
1.3.6.1.4.1.251.1.1.35.2.1.45ColumnpdhDS3AISDefectread-onlymandatoryReceive DS3 AIS Defect
1.3.6.1.4.1.251.1.1.35.2.1.46ColumnpdhDS3YellowDefectread-onlymandatoryDS3 Yellow Defect
1.3.6.1.4.1.251.1.1.35.2.1.47ColumnpdhDS3ExBERDefectread-onlymandatoryExcessive Bit Error Rate Defect
1.3.6.1.4.1.251.1.1.35.2.1.53ColumnpdhDS3LOSAlarmread-onlymandatoryDS3 Loss of Signal Alarm
1.3.6.1.4.1.251.1.1.35.2.1.54ColumnpdhDS3LOFAlarmread-onlymandatoryDS3 Loss of Frame Defect
1.3.6.1.4.1.251.1.1.35.2.1.55ColumnpdhDS3AISAlarmread-onlymandatoryReceive DS3 AIS Defect
1.3.6.1.4.1.251.1.1.35.2.1.56ColumnpdhDS3YellowAlarmread-onlymandatoryDS3 Yellow Alarm
1.3.6.1.4.1.251.1.1.35.2.1.57ColumnpdhDS3ExBERAlarmread-onlymandatoryExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.35.2.1.63ColumnpdhDS3LESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.35.2.1.64ColumnpdhDS3LSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.35.2.1.65ColumnpdhDS3ESread-onlymandatoryErrored Seconds
1.3.6.1.4.1.251.1.1.35.2.1.66ColumnpdhDS3ES2read-onlymandatorySecondary Errored Seconds (C-bit mode only)
1.3.6.1.4.1.251.1.1.35.2.1.67ColumnpdhDS3SESread-onlymandatorySeverely Errored Seconds
1.3.6.1.4.1.251.1.1.35.2.1.68ColumnpdhDS3SES2read-onlymandatorySecondary Severely Errored Seconds (C-bit mode only)
1.3.6.1.4.1.251.1.1.35.2.1.69ColumnpdhDS3AISSread-onlymandatoryAIS Seconds
1.3.6.1.4.1.251.1.1.35.2.1.70ColumnpdhDS3UASread-onlymandatoryUnavailable Seconds
1.3.6.1.4.1.251.1.1.35.2.1.71ColumnpdhDS3FarEndESread-onlymandatoryFar End Errored Seconds
1.3.6.1.4.1.251.1.1.35.2.1.72ColumnpdhDS3FarEndSESread-onlymandatoryFar End Severely Errored Seconds
1.3.6.1.4.1.251.1.1.35.2.1.73ColumnpdhDS3FarEndUASread-onlymandatoryFar End Unavailable Seconds
1.3.6.1.4.1.251.1.1.35.3TablepdhE3Tablenot-accessiblemandatoryThis table is used for E3 config/status supplied by the PLPP chip
1.3.6.1.4.1.251.1.1.35.3.1RowpdhE3Entrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.35.3.1.1ColumnpdhE3TableValidread-onlymandatoryIndicates if table is valid for configured LIM
1.3.6.1.4.1.251.1.1.35.3.1.2ColumnpdhE3LinkNoread-onlymandatoryLink Number
1.3.6.1.4.1.251.1.1.35.3.1.3ColumnpdhE3Framerread-writemandatoryE3 framer mode
1.3.6.1.4.1.251.1.1.35.3.1.4ColumnpdhE3Clearread-writemandatoryClear Button for Counters
1.3.6.1.4.1.251.1.1.35.3.1.5ColumnpdhE3Reconfigread-writemandatoryReconfigure link
1.3.6.1.4.1.251.1.1.35.3.1.6ColumnpdhE3TxmtTimMkread-writemandatorySet to yes(1) if traceable to primary ref clk.
1.3.6.1.4.1.251.1.1.35.3.1.7ColumnpdhE3PloadTypeLabread-writemandatoryPayload type label.
1.3.6.1.4.1.251.1.1.35.3.1.8ColumnpdhE3TxTrlTrcIdLenread-writemandatoryTrail trace length for transmit and expected receive.
1.3.6.1.4.1.251.1.1.35.3.1.9ColumnpdhE3TxTrcIdUHread-writemandatoryTransmit trail trace ID upper half.
1.3.6.1.4.1.251.1.1.35.3.1.10ColumnpdhE3TxTrcIdLHread-writemandatoryTransmit trail trace ID lower half.
1.3.6.1.4.1.251.1.1.35.3.1.11ColumnpdhE3RxExTrcIdUHread-writemandatoryReceive expected trail trace ID upper half.
1.3.6.1.4.1.251.1.1.35.3.1.12ColumnpdhE3RxExTrcIdLHread-writemandatoryReceive expected trail trace ID lower half.
1.3.6.1.4.1.251.1.1.35.3.1.32ColumnpdhE3FrameErrsread-onlymandatoryE3 frame error count
1.3.6.1.4.1.251.1.1.35.3.1.33ColumnpdhE3Lcvsread-onlymandatoryE3 Line Code Violation count
1.3.6.1.4.1.251.1.1.35.3.1.34ColumnpdhE3ParityErrsread-onlymandatoryE3-G832 parity error count
1.3.6.1.4.1.251.1.1.35.3.1.35ColumnpdhE3FEBEErrsread-onlymandatoryE3-G832 FEBE error count
1.3.6.1.4.1.251.1.1.35.3.1.41ColumnpdhE3LOSDefectread-onlymandatoryLOS Defect
1.3.6.1.4.1.251.1.1.35.3.1.42ColumnpdhE3OOFDefectread-onlymandatoryLOF Defect
1.3.6.1.4.1.251.1.1.35.3.1.43ColumnpdhE3AISDefectread-onlymandatoryAIS Defect
1.3.6.1.4.1.251.1.1.35.3.1.44ColumnpdhE3FERFDefectread-onlymandatoryFERF Defect
1.3.6.1.4.1.251.1.1.35.3.1.45ColumnpdhE3ExBERDefectread-onlymandatoryExcessive Bit Error Rate Defect
1.3.6.1.4.1.251.1.1.35.3.1.51ColumnpdhE3LOSAlarmread-onlymandatoryLOS Alarm
1.3.6.1.4.1.251.1.1.35.3.1.52ColumnpdhE3LOFAlarmread-onlymandatoryLOF Alarm
1.3.6.1.4.1.251.1.1.35.3.1.53ColumnpdhE3AISAlarmread-onlymandatoryAIS Alarm
1.3.6.1.4.1.251.1.1.35.3.1.54ColumnpdhE3FERFAlarmread-onlymandatoryFERF Alarm
1.3.6.1.4.1.251.1.1.35.3.1.55ColumnpdhE3ExBERAlarmread-onlymandatoryExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.35.3.1.61ColumnpdhE3LESread-onlymandatoryLine Errored Seconds
1.3.6.1.4.1.251.1.1.35.3.1.62ColumnpdhE3LSESread-onlymandatoryLine Severely Errored Seconds
1.3.6.1.4.1.251.1.1.35.3.1.63ColumnpdhE3ESread-onlymandatoryErrored Seconds
1.3.6.1.4.1.251.1.1.35.3.1.64ColumnpdhE3SESread-onlymandatorySeverely Errored Seconds
1.3.6.1.4.1.251.1.1.35.3.1.65ColumnpdhE3AISSread-onlymandatoryAIS Seconds
1.3.6.1.4.1.251.1.1.35.3.1.66ColumnpdhE3UASread-onlymandatoryUnavailable Seconds
1.3.6.1.4.1.251.1.1.35.3.1.76ColumnpdhE3RxTrlTrcread-onlymandatoryLast received trail trace message.
1.3.6.1.4.1.251.1.1.35.3.1.77ColumnpdhE3RxTrIdMisread-onlymandatoryReceive trace id mismatch indication.
1.3.6.1.4.1.251.1.1.35.3.1.78ColumnpdhE3RxTrIdUnstread-onlymandatoryReceive trace id unstable indication.
1.3.6.1.4.1.251.1.1.35.3.1.79ColumnpdhE3RxPloadTypeLabMisread-onlymandatoryReceive payload type label mismatch indication.
1.3.6.1.4.1.251.1.1.35.3.1.80ColumnpdhE3RxPloadTypeLabUnstread-onlymandatoryReceive payload type label unstable indication.
1.3.6.1.4.1.251.1.1.36Nodedv2Oam
1.3.6.1.4.1.251.1.1.36.1TableoamTablenot-accessiblemandatoryThis table is used for per-port OAM configuration.
1.3.6.1.4.1.251.1.1.36.1.1RowoamEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.36.1.1.1ColumnoamLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.36.1.1.2ColumnoamSegEndPointread-writemandatorySet to yes(1) to configure the link as segment end point.
1.3.6.1.4.1.251.1.1.36.1.1.3ColumnoamVcEndPointread-writemandatorySet to yes(1) to configure the link as connection end point.
1.3.6.1.4.1.251.1.1.36.1.1.4ColumnoamAisRdiGenerationread-writemandatorySet to yes(1) to generate AIS/RDI up on physical failure.
1.3.6.1.4.1.251.1.1.36.1.1.5ColumnoamLastRxTyperead-onlymandatoryType of the last received OAM cell.
1.3.6.1.4.1.251.1.1.36.1.1.6ColumnoamLastRxVpiread-onlymandatoryVPI value of the last received OAM cell.
1.3.6.1.4.1.251.1.1.36.1.1.7ColumnoamLastRxVciread-onlymandatoryVCI value of the last received OAM cell.
1.3.6.1.4.1.251.1.1.36.1.1.8ColumnoamRxCountread-onlymandatorySum of received OAM cells.
1.3.6.1.4.1.251.1.1.36.1.1.9ColumnoamLastTxTyperead-onlymandatoryType of the last transmitted OAM cell.
1.3.6.1.4.1.251.1.1.36.1.1.10ColumnoamLastTxVpiread-onlymandatoryVPI value of the last transmitted OAM cell.
1.3.6.1.4.1.251.1.1.36.1.1.11ColumnoamLastTxVciread-onlymandatoryVCI value of the last transmitted OAM cell.
1.3.6.1.4.1.251.1.1.36.1.1.12ColumnoamTxCountread-onlymandatorySum of transmitted OAM cells.
1.3.6.1.4.1.251.1.1.36.1.1.13ColumnoamClearStatsread-writemandatorySet to yes(2) to clear OAM Tx and Rx Statistics.
1.3.6.1.4.1.251.1.1.36.2TableoamLoopbackTablenot-accessiblemandatoryThis table is used to configure and control loopback test. Change Test Status to Start Test(1) to initiate loopback test.
1.3.6.1.4.1.251.1.1.36.2.1RowoamLoopbackEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.36.2.1.1ColumnoamLoopbackLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.36.2.1.2ColumnoamLoopbackVpiread-writemandatoryVPI value for the loopback cells to send.
1.3.6.1.4.1.251.1.1.36.2.1.3ColumnoamLoopbackVciread-writemandatoryVCI value for the loopback cells to send.
1.3.6.1.4.1.251.1.1.36.2.1.4ColumnoamLoopbackSpanread-writemandatoryFlow span for the loopback cells to send.
1.3.6.1.4.1.251.1.1.36.2.1.5ColumnoamLoopbackMaxNumCellsread-writemandatoryMaximum number of loopback cells to send.
1.3.6.1.4.1.251.1.1.36.2.1.6ColumnoamLoopbackNumCellsSentread-onlymandatoryNumber of loopback cells sent.
1.3.6.1.4.1.251.1.1.36.2.1.7ColumnoamLoopbackTimeOutread-writemandatoryNumber of seconds to wait for loopback cells to return.
1.3.6.1.4.1.251.1.1.36.2.1.8ColumnoamLoopbackActiveread-writemandatoryChange to Start Test to run loopback test.
1.3.6.1.4.1.251.1.1.36.2.1.9ColumnoamLoopbackResultread-onlymandatoryLoopback test result.
1.3.6.1.4.1.251.1.1.36.2.1.10ColumnoamLoopbackLocIdread-writemandatoryLocation Node ID for loopback point.
1.3.6.1.4.1.251.1.1.36.3ScalaroamDisableread-writemandatoryyes(2) will disable the oam for entire slot.
1.3.6.1.4.1.251.1.1.36.4TableoamVcaTablenot-accessiblemandatoryThis table is used for per-port OAM configuration.
1.3.6.1.4.1.251.1.1.36.4.1RowoamVcaEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.36.4.1.1ColumnoamVcaVpiread-onlymandatoryThe VPI for this configuration.
1.3.6.1.4.1.251.1.1.36.4.1.2ColumnoamVcaVciread-onlymandatoryThe VCI for this configuration.
1.3.6.1.4.1.251.1.1.36.4.1.3ColumnoamVcaConnectionTyperead-writemandatorySet End point configuration on hardware per VPC/VCC
1.3.6.1.4.1.251.1.1.36.4.1.4ColumnoamVcaVpcEndPointread-writemandatorySet yes(1) to configure the VC to VPC end point.
1.3.6.1.4.1.251.1.1.36.4.1.5ColumnoamVcaAisRdiGenerationread-writemandatoryAIS/RDI disable or enable with or without traps.
1.3.6.1.4.1.251.1.1.36.4.1.6ColumnoamVcaAisRdiStateread-onlymandatoryAIS/RDI state for this VP/VC.
1.3.6.1.4.1.251.1.1.36.4.1.7ColumnoamVcaDefectTyperead-onlymandatoryAIS/RDI defect type.
1.3.6.1.4.1.251.1.1.36.4.1.8ColumnoamVcaDefectNoderead-onlymandatoryAIS/RDI location.
1.3.6.1.4.1.251.1.1.36.4.1.9ColumnoamVcaDefectSlotread-onlymandatoryAIS/RDI location.
1.3.6.1.4.1.251.1.1.36.4.1.10ColumnoamVcaDefectLinkread-onlymandatoryAIS/RDI location.
1.3.6.1.4.1.251.1.1.36.4.1.11ColumnoamVcaTrapEnableread-writemandatorySet enable to generate trap when AIS/RDI received.
1.3.6.1.4.1.251.1.1.36.4.1.12ColumnoamVcaCCread-writemandatoryActivate segment or end to end Continuity Checks.
1.3.6.1.4.1.251.1.1.36.4.1.13ColumnoamVcaCCStateread-onlymandatoryContinuity Check state.
1.3.6.1.4.1.251.1.1.36.4.1.14ColumnoamVcaPMread-writemandatoryActivate segment or end to end Performance Monitoring.
1.3.6.1.4.1.251.1.1.36.4.1.15ColumnoamVcaPMBlockSizeread-writemandatoryPerformance Monitoring block size.
1.3.6.1.4.1.251.1.1.36.4.1.16ColumnoamVcaPMStateread-onlymandatoryContinuity Check state.
1.3.6.1.4.1.251.1.1.36.4.1.17ColumnoamVcaBkwRptLosCellsread-onlymandatoryBackward Reporting loss of cell.
1.3.6.1.4.1.251.1.1.36.4.1.18ColumnoamVcaBkwRptMisCellsread-onlymandatoryBackward Reporting misinserted cell.
1.3.6.1.4.1.251.1.1.36.4.1.19ColumnoamVcaBkwRptBip16read-onlymandatoryBackward Reporting BIP-16 violations.
1.3.6.1.4.1.251.1.1.36.4.1.20ColumnoamVcaBkwRptSevErrread-onlymandatoryBackward Reporting Severly Errored Cells.
1.3.6.1.4.1.251.1.1.36.5TableoamVcbTablenot-accessiblemandatoryThis table is used for per-port OAM configuration.
1.3.6.1.4.1.251.1.1.36.5.1RowoamVcbEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.36.5.1.1ColumnoamVcbVpiread-onlymandatoryThe VPI for this configuration.
1.3.6.1.4.1.251.1.1.36.5.1.2ColumnoamVcbVciread-onlymandatoryThe VCI for this configuration.
1.3.6.1.4.1.251.1.1.36.5.1.3ColumnoamVcbConnectionTyperead-writemandatorySet End point configuration on hardware per VPC/VCC
1.3.6.1.4.1.251.1.1.36.5.1.4ColumnoamVcbVpcEndPointread-writemandatorySet yes(1) to configure the VC to VPC end point.
1.3.6.1.4.1.251.1.1.36.5.1.5ColumnoamVcbAisRdiGenerationread-writemandatoryAIS/RDI disable or enable with or without traps.
1.3.6.1.4.1.251.1.1.36.5.1.6ColumnoamVcbAisRdiStateread-onlymandatoryAIS/RDI state for this VP/VC.
1.3.6.1.4.1.251.1.1.36.5.1.7ColumnoamVcbDefectTyperead-onlymandatoryAIS/RDI defect type.
1.3.6.1.4.1.251.1.1.36.5.1.8ColumnoamVcbDefectNoderead-onlymandatoryAIS/RDI location.
1.3.6.1.4.1.251.1.1.36.5.1.9ColumnoamVcbDefectSlotread-onlymandatoryAIS/RDI location.
1.3.6.1.4.1.251.1.1.36.5.1.10ColumnoamVcbDefectLinkread-onlymandatoryAIS/RDI location.
1.3.6.1.4.1.251.1.1.36.5.1.11ColumnoamVcbTrapEnableread-writemandatorySet enable to generate trap when AIS/RDI received.
1.3.6.1.4.1.251.1.1.36.5.1.12ColumnoamVcbCCread-writemandatoryActivate segment or end to end Continuity Checks.
1.3.6.1.4.1.251.1.1.36.5.1.13ColumnoamVcbCCStateread-onlymandatoryContinuity Check state.
1.3.6.1.4.1.251.1.1.36.5.1.14ColumnoamVcbPMread-writemandatoryActivate segment or end to end Performance Monitoring.
1.3.6.1.4.1.251.1.1.36.5.1.15ColumnoamVcbPMBlockSizeread-writemandatoryPerformance Monitoring block size.
1.3.6.1.4.1.251.1.1.36.5.1.16ColumnoamVcbPMStateread-onlymandatoryContinuity Check state.
1.3.6.1.4.1.251.1.1.36.5.1.17ColumnoamVcbBkwRptLosCellsread-onlymandatoryBackward Reporting loss of cell.
1.3.6.1.4.1.251.1.1.36.5.1.18ColumnoamVcbBkwRptMisCellsread-onlymandatoryBackward Reporting misinserted cell.
1.3.6.1.4.1.251.1.1.36.5.1.19ColumnoamVcbBkwRptBip16read-onlymandatoryBackward Reporting BIP-16 violations.
1.3.6.1.4.1.251.1.1.36.5.1.20ColumnoamVcbBkwRptSevErrread-onlymandatoryBackward Reporting Severly Errored Cells.
1.3.6.1.4.1.251.1.1.37Nodedv2Lmi
1.3.6.1.4.1.251.1.1.37.1TablelmiTablenot-accessiblemandatoryThis table is used to control ILMI configuration.
1.3.6.1.4.1.251.1.1.37.1.1RowlmiEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.37.1.1.1ColumnlmiLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.37.1.1.2ColumnlmiVpiread-writemandatoryThe VPI used for ILMI.
1.3.6.1.4.1.251.1.1.37.1.1.3ColumnlmiVciread-writemandatoryThe VCI used for ILMI.
1.3.6.1.4.1.251.1.1.37.1.1.4ColumnlmiTyperead-writemandatorySet to network side (1) to configure the link as network side ILMI.
1.3.6.1.4.1.251.1.1.37.1.1.5ColumnlmiStateread-onlymandatoryThe state of ILMI for this link.
1.3.6.1.4.1.251.1.1.37.1.1.6ColumnlmiFormatread-writemandatoryILMI address format.
1.3.6.1.4.1.251.1.1.37.1.1.7ColumnlmiPrefixread-onlymandatoryDefault Network prefix to use.
1.3.6.1.4.1.251.1.1.37.1.1.8ColumnlmiOnOffread-writemandatoryTurn on/off ILMI.
1.3.6.1.4.1.251.1.1.37.1.1.9ColumnlmiPollPeriodread-writemandatoryPeriod in seconds to send polling request for link management.
1.3.6.1.4.1.251.1.1.37.1.1.10ColumnlmiNoRspDownread-writemandatoryNumber of failed polls (no response) before declaration of link down.
1.3.6.1.4.1.251.1.1.37.1.1.11ColumnlmiLinkMgmtread-writemandatoryTurn on/off link management.
1.3.6.1.4.1.251.1.1.37.1.1.12ColumnlmiConnectivityread-onlymandatoryATM interface status.
1.3.6.1.4.1.251.1.1.37.1.1.13ColumnlmiPrefixModread-writemandatoryModifiable Network prefix to use. MUST BE 26 DIGITS
1.3.6.1.4.1.251.1.1.37.1.1.14ColumnlmiEsiread-writemandatoryESI field to use on User side. MUST BE 12 DIGITS
1.3.6.1.4.1.251.1.1.37.2TablelmiNetSideTablenot-accessiblemandatoryThis table is used to configure and control network side ILMI.
1.3.6.1.4.1.251.1.1.37.2.1RowlmiNetSideEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.37.2.1.1ColumnlmiNetSideLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.37.2.1.2ColumnlmiNetSidePrefixIdread-onlymandatoryNetwork prefix identification number.
1.3.6.1.4.1.251.1.1.37.2.1.3ColumnlmiNetSidePrefixread-onlymandatoryNetwork prefix to register or de-register.
1.3.6.1.4.1.251.1.1.37.2.1.4ColumnlmiNetSidePrefixStatusread-onlymandatorySet to register to send the prefix to the user side; set to de-register to remove the prefix from the user side.
1.3.6.1.4.1.251.1.1.37.3TablelmiUserSideTablenot-accessiblemandatoryThis table is used to configure and control user side ILMI.
1.3.6.1.4.1.251.1.1.37.3.1RowlmiUserSideEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.37.3.1.1ColumnlmiUserSideLinkNoread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.37.3.1.2ColumnlmiUserSideAddressIdread-onlymandatoryThe link number for this configuration.
1.3.6.1.4.1.251.1.1.37.3.1.3ColumnlmiUserSideAddressread-onlymandatoryATM address to register or de-register.
1.3.6.1.4.1.251.1.1.37.3.1.4ColumnlmiUserSideAddressStatusread-onlymandatorySet to valid to register the address to the network side; set to invalid to de-register the address from the network side.
1.3.6.1.4.1.251.1.1.38Nodedv2AlarmHandler
1.3.6.1.4.1.251.1.1.38.1ScalaralarmNodeCritread-onlymandatoryNode Critical Alarm Status
1.3.6.1.4.1.251.1.1.38.2ScalaralarmNodeMajorread-onlymandatoryNode Major Alarm Status
1.3.6.1.4.1.251.1.1.38.3ScalaralarmNodeMinorread-onlymandatoryNode Minor Alarm Status
1.3.6.1.4.1.251.1.1.38.4TablealarmStatTablenot-accessiblemandatoryThis table is used for Alarm Handler status
1.3.6.1.4.1.251.1.1.38.4.1RowalarmStatEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.38.4.1.1ColumnalrStatSlotNoread-onlymandatorySlot Number
1.3.6.1.4.1.251.1.1.38.4.1.2ColumnslotCritStatusread-onlymandatorySlot Critical Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.3ColumnslotMajorStatusread-onlymandatorySlot Major Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.4ColumnslotMinorStatusread-onlymandatorySlot Minor Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.5Columnlink0CritStatusread-onlymandatoryLink 0 Critical Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.6Columnlink0MajorStatusread-onlymandatoryLink 0 Major Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.7Columnlink0MinorStatusread-onlymandatoryLink 0 Minor Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.8Columnlink1CritStatusread-onlymandatoryLink 1 Critical Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.9Columnlink1MajorStatusread-onlymandatoryLink 1 Major Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.10Columnlink1MinorStatusread-onlymandatoryLink 1 Minor Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.11Columnlink2CritStatusread-onlymandatoryLink 2 Critical Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.12Columnlink2MajorStatusread-onlymandatoryLink 2 Major Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.13Columnlink2MinorStatusread-onlymandatoryLink 2 Minor Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.14Columnlink3CritStatusread-onlymandatoryLink 3 Critical Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.15Columnlink3MajorStatusread-onlymandatoryLink 3 Major Alarm Status
1.3.6.1.4.1.251.1.1.38.4.1.16Columnlink3MinorStatusread-onlymandatoryLink 3 Minor Alarm Status
1.3.6.1.4.1.251.1.1.38.5ScalaralarmNodeACOread-writemandatoryNode ACO Status
1.3.6.1.4.1.251.1.1.38.6TablealarmACOTablenot-accessiblemandatoryThis table is used for the Alarm Handler ACO
1.3.6.1.4.1.251.1.1.38.6.1RowalarmACOEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.38.6.1.1ColumnalrACOslotNoread-onlymandatorySlot Number
1.3.6.1.4.1.251.1.1.38.6.1.2ColumnalrACOslotACOread-writemandatorySlot ACO Status
1.3.6.1.4.1.251.1.1.38.6.1.3ColumnalrACOlink0ACOread-writemandatoryLink 0 ACO Status
1.3.6.1.4.1.251.1.1.38.6.1.4ColumnalrACOlink1ACOread-writemandatoryLink 1 ACO Status
1.3.6.1.4.1.251.1.1.38.6.1.5ColumnalrACOlink2ACOread-writemandatoryLink 2 ACO Status
1.3.6.1.4.1.251.1.1.38.6.1.6ColumnalrACOlink3ACOread-writemandatoryLink 3 ACO Status
1.3.6.1.4.1.251.1.1.38.7TableuserStatusTablenot-accessiblemandatoryThis table is used for the User Status Inputs
1.3.6.1.4.1.251.1.1.38.7.1RowuserStatusEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.38.7.1.1ColumnuserInputNoread-onlymandatoryUser Status Input Number
1.3.6.1.4.1.251.1.1.38.7.1.2ColumnuserInputEnableread-writemandatoryEnable User Status Input
1.3.6.1.4.1.251.1.1.38.7.1.3ColumnuserInputTrapEnableread-writemandatoryEnable User Defined Trap/Event
1.3.6.1.4.1.251.1.1.38.7.1.4ColumnuserInputTrapDescread-writemandatoryDescription string for trap/event
1.3.6.1.4.1.251.1.1.38.7.1.5ColumnuserInputActiveStateread-writemandatoryAlarm active state of user input relay switch
1.3.6.1.4.1.251.1.1.38.7.1.10ColumnuserInputAlrClassread-onlymandatoryClassification of Status/Alarm Input
1.3.6.1.4.1.251.1.1.38.7.1.11ColumnuserInputStatusread-onlymandatoryCurrent Status of Status/Alarm Input
1.3.6.1.4.1.251.1.1.38.8ScalaralarmScanFileread-writemandatoryRescan the alr_class.txt file
1.3.6.1.4.1.251.1.1.39Nodedv2Cac
1.3.6.1.4.1.251.1.1.39.1ScalarcacCurrentEbtIdread-onlymandatoryCurrent EBT file ID code. <DETAIL_DESCRIPTION> cacCurrentEbtId holds the EBT file ID code of the EBT file currently in memory in a verified state. The CAC appl…
1.3.6.1.4.1.251.1.1.39.2ScalarcacEbtCommandread-writemandatoryEBT file command. <DETAIL_DESCRIPTION> This field, normally with the value none, may be set by the manager to: * load-ebt to initiate the loading of a new EBT …
1.3.6.1.4.1.251.1.1.39.3ScalarcacCommandEbtIdread-writemandatoryCommand EBT file ID code. <DETAIL_DESCRIPTION> cacCommandEbtId is written to by the manager to identify the EBT file in the flash that should be loaded or dele…
1.3.6.1.4.1.251.1.1.39.4ScalarcacEbtStateread-onlymandatoryState of the CAC. <DETAIL_DESCRIPTION> The state: * uninitialized is an initial MIB value which is never returned to without starting from a new MIB. * initial…
1.3.6.1.4.1.251.1.1.39.5ScalarcacErrorCoderead-onlymandatoryError code. <DETAIL_DESCRIPTION> Error codes are produced at certain stages in the CAC application. The interpretation of the error codes is: Terms: 'ebXXXXX.b…
1.3.6.1.4.1.251.1.1.39.6TablecacPerLinkTablenot-accessiblemandatoryThis table containing per link data. <DETAIL_DESCRIPTION> Contains per link specific data
1.3.6.1.4.1.251.1.1.39.6.1RowcacPerLinkEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.39.6.1.1ColumncacLinkNoread-onlymandatoryLink number. <DETAIL_DESCRIPTION> cacLinkNo is the index (0..3) to the array of link data.
1.3.6.1.4.1.251.1.1.39.6.1.2ColumncacLinkSumE10read-onlymandatoryRunning sum of e10. <DETAIL_DESCRIPTION> cacSumE10 zero loss effective bandwidth for high priority queue. This value is maintained only when the CAC is enabled…
1.3.6.1.4.1.251.1.1.39.6.1.3ColumncacLinkSumE1Tread-onlymandatoryRunning sum of e1T. <DETAIL_DESCRIPTION> cacSumE1T tangent effective bandwidth for high priority queue. This value is maintained only when the CAC is enabled o…
1.3.6.1.4.1.251.1.1.39.6.1.4ColumncacLinkObfPvc1read-writemandatoryUtilization factor for high priority pvc. <DETAIL_DESCRIPTION> Utilization factor for PVCs and SPVCs for the high priority queue.
1.3.6.1.4.1.251.1.1.39.6.1.5ColumncacLinkObfSvc1read-writemandatoryUtilization factor for high priority svc. <DETAIL_DESCRIPTION> Utilization factor for SVCs for the high priority queue.
1.3.6.1.4.1.251.1.1.39.6.1.6ColumncacLinkSumE20read-onlymandatoryRunning sum of e20. <DETAIL_DESCRIPTION> cacSumE20 zero loss effective bandwidth for low priority queue. This value is maintained only when the CAC is enabled …
1.3.6.1.4.1.251.1.1.39.6.1.7ColumncacLinkSumE2Tread-onlymandatoryRunning sum of e2T. <DETAIL_DESCRIPTION> cacSumE1T zero tangent effective bandwidth for low priority queue. This value is maintained only when the CAC is enabl…
1.3.6.1.4.1.251.1.1.39.6.1.8ColumncacLinkObfPvc2read-writemandatoryUtilization factor for low priority pvc. <DETAIL_DESCRIPTION> Utilization factor for PVCs and SPVCs for the low priority queue.
1.3.6.1.4.1.251.1.1.39.6.1.9ColumncacLinkObfSvc2read-writemandatoryUtilization factor for low priority svc. <DETAIL_DESCRIPTION> Utilization factor for SVCs for the low priority queue.
1.3.6.1.4.1.251.1.1.39.6.1.10ColumncacLinkTotalBwScrPcrread-onlymandatorytotal bw allocation on the link by scr-pcr CAC. <DETAIL_DESCRIPTION> cacTotalBwScrPcr is the total bandwidth allocated to extant connections when the CAC is en…
1.3.6.1.4.1.251.1.1.39.6.1.11ColumncacCurrentLinkUsageread-onlymandatoryCurrent link bandwidth allocation. <DETAIL_DESCRIPTION> It is the current indication of bandwidth allocation on a link based on the formula using effective ban…
1.3.6.1.4.1.251.1.1.39.6.1.12ColumncacMaxLinkUsageread-onlymandatoryMax link bw allocation since last reset or card boot. <DETAIL_DESCRIPTION> cacMaxLinkUsage shows the maximum value that cacCurrentLinkUsage has reached since c…
1.3.6.1.4.1.251.1.1.39.6.1.13ColumncacLinkResetread-writemandatoryReload maximum link usage from current allocation. <DETAIL_DESCRIPTION> cacReset resets cacMaxLinkUsage, after the reset cacMaxLinkUsage shows the same value a…
1.3.6.1.4.1.251.1.1.39.6.1.14ColumncacLinkVersionread-writemandatoryUse EB CAC or scr-pcr CAC? <DETAIL_DESCRIPTION> The per-link variable cacVersion may take on the values * SCR-PCR indicating that the old, pre Rel 4.2 CAC base…
1.3.6.1.4.1.251.1.1.39.6.1.15ColumncacLinkEnableread-writemandatoryEnable cac? <DETAIL_DESCRIPTION> When cacEnable has the value * yes, then the three CAC service routines are operational as defined, * no, then all connections…
1.3.6.1.4.1.251.1.1.39.6.1.16ColumncacLinkSignalModeread-onlymandatoryLink signalling mode <DETAIL_DESCRIPTION> cacSignallingMode is a read-only variable indicating whether the link is currently in the signalling mode: * single-c…
1.3.6.1.4.1.251.1.1.39.6.1.17ColumncacLinkStateread-onlymandatoryState of the Link <DETAIL_DESCRIPTION> The cacLinkState variable can take the values: * uninitialised is an initial MIB value which is never returned to withou…
1.3.6.1.4.1.251.1.1.39.7TablecacPerSapTablenot-accessiblemandatoryThis table containing per Sap data. <DETAIL_DESCRIPTION> The virtual SAP table in the MIB has 12 entries indexed by cacSapNo in the range (20..31). For each SA…
1.3.6.1.4.1.251.1.1.39.7.1RowcacPerSapEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.39.7.1.1ColumncacSapNoread-onlymandatorySAP number. <DETAIL_DESCRIPTION> cacSapNo is the index (0..11) to the array of sap data.
1.3.6.1.4.1.251.1.1.39.7.1.2ColumncacSapSumE1Tread-onlymandatoryRunning sum of e1T. <DETAIL_DESCRIPTION> cacSumE1T tangent effective bandwidth for high priority queue These values are maintained only when the CAC is enabled…
1.3.6.1.4.1.251.1.1.39.7.1.3ColumncacSapSumE2Tread-onlymandatoryRunning sum of e2T. <DETAIL_DESCRIPTION> cacSumE1T tangent effective bandwidth for low priority queue These values are maintained only when the CAC is enabled …
1.3.6.1.4.1.251.1.1.39.7.1.4ColumncacSapTotalBwScrPcrread-onlymandatorytotal bw allocation on the link by scr-pcr CAC. <DETAIL_DESCRIPTION> cacTotalBwScrPcr is the total bandwidth allocated to extant connections when the CAC is en…
1.3.6.1.4.1.251.1.1.39.7.1.5ColumncacCurrentSapUsageread-onlymandatoryCurrent SAP bandwidth allocation <DETAIL_DESCRIPTION> It is the current indication of bandwidth allocation on a sap based on the formula using effective bandwi…
1.3.6.1.4.1.251.1.1.39.7.1.6ColumncacMaxSapUsageread-onlymandatoryMax SAP b/w allocation since last reset or card boot. <DETAIL_DESCRIPTION> cacMaxSapUsage shows the maximum value that cacCurrentSapUsage has reached since cac…
1.3.6.1.4.1.251.1.1.39.7.1.7ColumncacSapResetread-writemandatoryReload maximum SAP usage from current allocation <DETAIL_DESCRIPTION> cacReset resets cacMaxSapUsage, after the reset cacMaxSapUsage shows the same value as ca…
1.3.6.1.4.1.251.1.1.40Nodedv2MS2FRAC
1.3.6.1.4.1.251.1.1.41Nodedv2aal5
1.3.6.1.4.1.251.1.1.42Nodevhsystem
1.3.6.1.4.1.251.1.1.42.1ScalarlimHostRevread-onlymandatoryHost S/W Revision
1.3.6.1.4.1.251.1.1.42.2ScalarlimBootRevread-onlymandatoryBoot S/W Revision
1.3.6.1.4.1.251.1.1.42.3ScalarlimHwRevread-onlymandatoryHardware Architecture
1.3.6.1.4.1.251.1.1.42.4ScalarlimActionread-writemandatoryLIM action
1.3.6.1.4.1.251.1.1.42.5ScalarlimStateread-onlymandatoryLIM state
1.3.6.1.4.1.251.1.1.42.6ScalarlimFaultread-onlymandatoryLIM Fault LED
1.3.6.1.4.1.251.1.1.42.7ScalarlimFaultReasonread-onlymandatoryLIM Fault Reason
1.3.6.1.4.1.251.1.1.42.8ScalarlimCodec0read-onlymandatoryH.320 Codec 0 Active LED
1.3.6.1.4.1.251.1.1.42.9ScalarlimCodec1read-onlymandatoryH.320 Codec 1 Active LED
1.3.6.1.4.1.251.1.1.42.10ScalarlimSCmgmtread-onlymandatorySlot Controller Mgmt Link Status
1.3.6.1.4.1.251.1.1.42.11ScalarlimSCmgmtDataread-onlymandatorySlot Controller Mgmt Information Data State
1.3.6.1.4.1.251.1.1.42.12ScalarlimSCfileXferReqread-writemandatorySlot Controller Mgmt File Transfer Request
1.3.6.1.4.1.251.1.1.42.13ScalarlimSCfileXferStatread-onlymandatorySlot Controller Mgmt File Transfer State
1.3.6.1.4.1.251.1.1.42.14ScalarlimSCbytesread-onlymandatorySlot Controller Mgmt File Transfer Byte Count
1.3.6.1.4.1.251.1.1.43Nodevhcontrol
1.3.6.1.4.1.251.1.1.43.1TablectrlTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.1.1RowctrlEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.1.1.1ColumnctrlIndexread-onlymandatoryCodec Index
1.3.6.1.4.1.251.1.1.43.1.1.2ColumnctrlCodecTyperead-onlymandatoryCodec Type
1.3.6.1.4.1.251.1.1.43.1.1.3ColumnctrlCodecActionread-writemandatoryCodec Action
1.3.6.1.4.1.251.1.1.43.1.1.4ColumnctrlCodecReqread-writemandatoryCodec Request
1.3.6.1.4.1.251.1.1.43.1.1.5ColumnctrlCallTyperead-onlymandatoryCodec Call Type
1.3.6.1.4.1.251.1.1.43.1.1.6ColumnctrlCodecStaread-onlymandatoryCodec Status
1.3.6.1.4.1.251.1.1.43.1.1.7ColumnctrlChnlLpbkread-writemandatoryCodec Channel Loopback
1.3.6.1.4.1.251.1.1.43.1.1.8ColumnctrlFramingread-onlymandatoryCodec H.221 Framing Detected
1.3.6.1.4.1.251.1.1.43.1.1.9ColumnctrlChnlStatread-onlymandatoryCodec Channel Link Status
1.3.6.1.4.1.251.1.1.43.1.1.10ColumnctrlFaultReasonread-onlymandatoryCodec Fault Reason
1.3.6.1.4.1.251.1.1.43.2TablevidTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.2.1RowvidEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.2.1.1ColumnvidIndexread-onlymandatoryVH320 Codec Index
1.3.6.1.4.1.251.1.1.43.2.1.2ColumnvidStandardread-writemandatoryVH320 Analog Video I/O Standard
1.3.6.1.4.1.251.1.1.43.2.1.3ColumnvidTxVidReqread-writemandatoryVH320 Transmit Video Request
1.3.6.1.4.1.251.1.1.43.2.1.4ColumnvidRxVidReqread-writemandatoryVH320 Display Video Request
1.3.6.1.4.1.251.1.1.43.2.1.5ColumnvidViewPipread-writemandatoryVH320 View Self Picture in Picture
1.3.6.1.4.1.251.1.1.43.2.1.6ColumnvidCompQualread-writemandatoryVH320 Compression Quality
1.3.6.1.4.1.251.1.1.43.2.1.7ColumnvidDigLpbkread-writemandatoryVH320 Digital Loopback
1.3.6.1.4.1.251.1.1.43.2.1.8ColumnvidEncFrameCountread-onlymandatoryVH320 Video Encoded Frame Count
1.3.6.1.4.1.251.1.1.43.2.1.9ColumnvidDecFrameCountread-onlymandatoryVH320 Video Decoded Frame Count
1.3.6.1.4.1.251.1.1.43.2.1.10ColumnvidStateread-onlymandatoryVH320 Video State
1.3.6.1.4.1.251.1.1.43.2.1.11ColumnvidInPresentread-onlymandatoryVH320 Video Input Present
1.3.6.1.4.1.251.1.1.43.2.1.12ColumnvidEncBitRateread-onlymandatoryVH320 Encoded Bitrate (bps)
1.3.6.1.4.1.251.1.1.43.3TableaudTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.3.1RowaudEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.3.1.1ColumnaudIndexread-onlymandatoryVH320 Codec Index
1.3.6.1.4.1.251.1.1.43.3.1.2ColumnaudStateread-onlymandatoryVH320 Audio State
1.3.6.1.4.1.251.1.1.43.3.1.3ColumnaudPrefModeread-writemandatoryVH320 Audio Preferred Coding Mode
1.3.6.1.4.1.251.1.1.43.3.1.4ColumnaudCommModeread-onlymandatoryVH320 Audio Common Coding Mode
1.3.6.1.4.1.251.1.1.43.3.1.5ColumnaudBitRateread-onlymandatoryVH320 Audio Bit Rate (bps)
1.3.6.1.4.1.251.1.1.43.3.1.6ColumnaudMuteInReqread-writemandatoryVH320 Audio Mute Input Request
1.3.6.1.4.1.251.1.1.43.3.1.7ColumnaudMuteOutReqread-writemandatoryVH320 Audio Mute Output Request
1.3.6.1.4.1.251.1.1.43.3.1.8ColumnaudMuteOutStatread-onlymandatoryVH320 Audio Mute Output Status
1.3.6.1.4.1.251.1.1.43.3.1.9ColumnaudLpbkread-writemandatoryVH320 Audio Loopback Request
1.3.6.1.4.1.251.1.1.43.3.1.10ColumnaudInVolread-writemandatoryVH320 Audio Input Volume
1.3.6.1.4.1.251.1.1.43.3.1.11ColumnaudOutVolread-writemandatoryVH320 Audio Output Volume
1.3.6.1.4.1.251.1.1.43.3.1.12ColumnaudInDelayread-writemandatoryVH320 Audio Input Delay Request (ms)
1.3.6.1.4.1.251.1.1.43.3.1.13ColumnaudOutDelayread-writemandatoryVH320 Audio Output Delay Status (ms)
1.3.6.1.4.1.251.1.1.43.3.1.14ColumnaudFaultReasonread-onlymandatoryVH320 Audio Fault Reason
1.3.6.1.4.1.251.1.1.43.4TabledataTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.4.1RowdataEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.43.4.1.1ColumndataIndexread-onlymandatoryVH320 Codec Index
1.3.6.1.4.1.251.1.1.43.4.1.2ColumndataChnlTyperead-writemandatoryData Channel Type
1.3.6.1.4.1.251.1.1.43.4.1.3ColumndataPortSpeedread-writemandatoryData Port Speed (bps)
1.3.6.1.4.1.251.1.1.43.4.1.4ColumndataPortProtread-writemandatoryData Port Protocol
1.3.6.1.4.1.251.1.1.43.4.1.5ColumndataHDLCcheckread-writemandatoryHDLC Check CRC
1.3.6.1.4.1.251.1.1.43.4.1.6ColumndataChnlStatread-onlymandatoryData Channel Status
1.3.6.1.4.1.251.1.1.43.4.1.7ColumndataBytesRcvdread-onlymandatoryData Channel Bytes Received
1.3.6.1.4.1.251.1.1.43.4.1.8ColumndataBytesSentread-onlymandatoryData Channel Bytes Sent
1.3.6.1.4.1.251.1.1.43.4.1.9ColumndataResetStatread-writemandatoryData Channel Reset Statistics
1.3.6.1.4.1.251.1.1.44Nodevhmgmt
1.3.6.1.4.1.251.1.1.44.1TablemgmtTablenot-accessiblemandatory
1.3.6.1.4.1.251.1.1.44.1.1RowmgmtEntrynot-accessiblemandatory
1.3.6.1.4.1.251.1.1.44.1.1.1ColumnmgmtIndexread-onlymandatoryVH320 Management Port Index
1.3.6.1.4.1.251.1.1.44.1.1.2ColumnmgmtDescrread-onlymandatoryVH320 Management Port Descriptor
1.3.6.1.4.1.251.1.1.44.1.1.3ColumnmgmtPortProtread-writemandatoryManagement Port Protocol
1.3.6.1.4.1.251.1.1.44.1.1.4ColumnmgmtPortSpeedread-writemandatoryManagement Port Speed (bps)
1.3.6.1.4.1.251.1.1.44.1.1.5ColumnmgmtPortAddressread-writemandatoryManagement Port Address
1.3.6.1.4.1.251.1.1.44.1.1.6ColumnmgmtAddressMaskread-writemandatoryManagement Port Address Mask
1.3.6.1.4.1.251.1.1.44.1.1.7ColumnmgmtRemoteAddressread-writemandatoryManagement Remote Address
1.3.6.1.4.1.251.1.1.44.1.1.8ColumnmgmtPortStatread-onlymandatoryManagement Port Status
1.3.6.1.4.1.251.1.1.44.1.1.9ColumnmgmtBytesRcvdread-onlymandatoryManagement Bytes Received
1.3.6.1.4.1.251.1.1.44.1.1.10ColumnmgmtBytesSentread-onlymandatoryManagement Bytes Sent
1.3.6.1.4.1.251.1.1.44.1.1.11ColumnmgmtResetStatread-writemandatoryManagement Reset Statistics
1.3.6.1.4.1.251.1.1.76NodemainInServThis is sent when the Main Slot 0 Controller goes into service
1.3.6.1.4.1.251.1.1.77NodestandbyInServThis is sent when the Standby Slot 0 Controller goes into service
1.3.6.1.4.1.251.1.1.78Nodebill25pstfullThis is sent when billing table is 25% full.
1.3.6.1.4.1.251.1.1.79Nodebill75pstfullThis is sent when billing table is 75% full.
1.3.6.1.4.1.251.1.1.80Noderestart040This is sent when the master processor has been restarted by the 68302 processor.
1.3.6.1.4.1.251.1.1.81NodealcTxErrorThis is sent after master processor has been reset due to ALC-87 Transmitter Error.
1.3.6.1.4.1.251.1.1.91Nodelim-faultConfigured LIM type does not match the LIM in slot
1.3.6.1.4.1.251.1.1.92Nodelim-operLIM operational
1.3.6.1.4.1.251.1.1.93NodepsuAbsentPSU Absent detected
1.3.6.1.4.1.251.1.1.94NodepsuPresentPSU Presence detected
1.3.6.1.4.1.251.1.1.95NodeswitchFabricSwapSwitch Fabric Redundant Swap
1.3.6.1.4.1.251.1.1.106NodeinternalResetThis is sent after the software has detected an internal error and restarted itself.
1.3.6.1.4.1.251.1.1.107Nodeaal1FaultThis is sent when an AAL1 fault has occurred.
1.3.6.1.4.1.251.1.1.108Nodeaal1ClearThis is sent when an AAL1 fault has been cleared.
1.3.6.1.4.1.251.1.1.109Nodeds1LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.110Nodeds1LOFLoss of Frame alarm
1.3.6.1.4.1.251.1.1.111Nodeds1AISAIS alarm
1.3.6.1.4.1.251.1.1.112Nodeds1YellowYellow alarm
1.3.6.1.4.1.251.1.1.113Nodeds1ExBERExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.114Nodeds1v2LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.115Nodeds1v2LOFLoss of Frame alarm
1.3.6.1.4.1.251.1.1.116Nodeds1v2AISAIS alarm
1.3.6.1.4.1.251.1.1.117Nodeds1v2YellowYellow alarm
1.3.6.1.4.1.251.1.1.118Nodeds1v2ExBERExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.119Nodeds3LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.120Nodeds3V2LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.121Nodeds3LOFLoss of Frame alarm
1.3.6.1.4.1.251.1.1.122Nodeds3AISAIS alarm
1.3.6.1.4.1.251.1.1.123Nodeds3YellowYellow alarm
1.3.6.1.4.1.251.1.1.124Nodeds3ExBERExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.125Nodeds3FEFrmrDifReceived frame format is different than configured frame format
1.3.6.1.4.1.251.1.1.126Nodee1LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.127Nodee1LOFLoss of Frame alarm
1.3.6.1.4.1.251.1.1.128Nodee1AISAIS alarm
1.3.6.1.4.1.251.1.1.129Nodee1YellowYellow alarm
1.3.6.1.4.1.251.1.1.130Nodee1ExBERExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.131Nodee3LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.132Nodee3LOFLoss of Frame alarm
1.3.6.1.4.1.251.1.1.133Nodee3AISAIS alarm
1.3.6.1.4.1.251.1.1.134Nodee3YellowYellow alarm
1.3.6.1.4.1.251.1.1.135Nodee3ExBERExcessive Bit Error Rate Alarm
1.3.6.1.4.1.251.1.1.136NodelocdLoss Of Cell Delineation
1.3.6.1.4.1.251.1.1.137NodeplcpYellowPLCP yellow alarm
1.3.6.1.4.1.251.1.1.138NodeplcpLOFPLCP Loss of Frame alarm
1.3.6.1.4.1.251.1.1.139NodesdhLOSSONET/SDH Loss of Signal
1.3.6.1.4.1.251.1.1.140NodesdhLOFSONET/SDH Loss of Frame
1.3.6.1.4.1.251.1.1.141NodesdhLineAISSONET/SDH Line AIS failure
1.3.6.1.4.1.251.1.1.142NodesdhPathAISSONET/SDH Path AIS failure
1.3.6.1.4.1.251.1.1.143NodesdhLOPSONET/SDH Loss of Pointer
1.3.6.1.4.1.251.1.1.144NodesdhPLMSONET/SDH Path Label Mismatch
1.3.6.1.4.1.251.1.1.145NodesdhLineYellowSONET/SDH Line FERF failure
1.3.6.1.4.1.251.1.1.146NodesdhPathYellowSONET/SDH Path Yellow failure
1.3.6.1.4.1.251.1.1.147NodesdhExBERSONET/SDH Excessive Bit Error Rate
1.3.6.1.4.1.251.1.1.148NodeclockActiveRefCurrent Active Reference
1.3.6.1.4.1.251.1.1.149NodeoutOfResourceLink cell rate is not sufficient for established connections
1.3.6.1.4.1.251.1.1.150NodehssiLOSHSSI Loss of Signal
1.3.6.1.4.1.251.1.1.151NodehssiDTEReadyDTE is Ready
1.3.6.1.4.1.251.1.1.152NodehssiDCEReadyDCE is Ready
1.3.6.1.4.1.251.1.1.153NodehssiDTENotReadyDTE is not Ready
1.3.6.1.4.1.251.1.1.154NodehssiDCENotReadyDCE is not Ready
1.3.6.1.4.1.251.1.1.155Nodeuserstatus1
1.3.6.1.4.1.251.1.1.156Nodeuserstatus2
1.3.6.1.4.1.251.1.1.157NodepntmoperSent when Primary NTM card operational status changes
1.3.6.1.4.1.251.1.1.158NodesntmoperSent when Secondary NTM card operational status changes
1.3.6.1.4.1.251.1.1.159NodepntmoscstatusSent when Primary NTM card oscillator status changes
1.3.6.1.4.1.251.1.1.160NodesntmoscstatusSent when secondary NTM card oscillator status changes
1.3.6.1.4.1.251.1.1.161NodepbitslineokSent when Primary NTM card BITS line status changes
1.3.6.1.4.1.251.1.1.162NodesbitslineokSent when secondary NTM card BITS line status changes
1.3.6.1.4.1.251.1.1.163NodesvcHalfConnectSVC half connect detected
1.3.6.1.4.1.251.1.1.164NodeduplicateIpAddrSent When a duplicate IP address is detected.
1.3.6.1.4.1.251.1.1.165NodesvcQsaalResetSent when SAP is reset
1.3.6.1.4.1.251.1.1.166NodesvcQsaalUpDownSent when SAP transitions between Up and Down
1.3.6.1.4.1.251.1.1.167NodesvcT309ExpirySent when T309 timer expired and calls exist on a SAP
1.3.6.1.4.1.251.1.1.168Nodej2LOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.169Nodej2LOFLoss of Frame alarm
1.3.6.1.4.1.251.1.1.170Nodej2AISAIS alarm
1.3.6.1.4.1.251.1.1.171Nodej2RAIRAI alarm
1.3.6.1.4.1.251.1.1.172NodescfLOSLoss of Signal alarm
1.3.6.1.4.1.251.1.1.173NoderouteLoadFaildef.rtb file load failure
1.3.6.1.4.1.251.1.1.174NodedTLLoadFaildtl.bin file load failure
1.3.6.1.4.1.251.1.1.175NoderedunNotAvailThis is sent when the Redundant Slot 0 Controller is not available
1.3.6.1.4.1.251.1.1.176NoderedunAvailThis is sent when the Redundant Slot 0 Controller is available
1.3.6.1.4.1.251.1.1.177NodedQ7-errorThis trap is sent when edos discovers a DQ7 error in flash
1.3.6.1.4.1.251.1.1.178NodeoamVcaRcvAIS-RDIThis trap is generated when an AIS or RDI is received on VCa port
1.3.6.1.4.1.251.1.1.179NodeoamVcbRcvAIS-RDIThis trap is generated when an AIS or RDI is received on VCb port
Type Definitions
NameSyntaxStatusDescription
DateTimeStringOCTET STRING (SIZE (8))
E164OCTET STRING (SIZE (2..10))
E164SUBOCTET STRING (SIZE (2..22))
HexINTEGER (0..65535)
Q93bCauseDiagOCTET STRING (SIZE (4))
VirtualCircuitIdentifierINTEGER (0..65535)
VirtualPathIdentifierINTEGER (0..4095)