MIB Viewer

EF-6000-MIB

143 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.289NodemcData
1.3.6.1.4.1.289.1Nodeef6000PortScnAn ef6000PortScn(1) is generated whenever a Fc_Port changes its operational state. For instance, the Fc_Port goes from on-line to offline.
1.3.6.1.4.1.289.2NodecommDev
1.3.6.1.4.1.289.2Nodeef6000FruScnAn ef6000FruScn(2) is generated whenever a FRU status changes its operational state.
1.3.6.1.4.1.289.2.1NodefibreChannel
1.3.6.1.4.1.289.2.1.1NodefcSwitch
1.3.6.1.4.1.289.2.1.1.2Nodeef-6000
1.3.6.1.4.1.289.2.1.1.2.1Nodeef6000Sys
1.3.6.1.4.1.289.2.1.1.2.1.1Scalaref6000SysCurrentDateread-onlymandatoryThe current date information.
1.3.6.1.4.1.289.2.1.1.2.1.2Scalaref6000SysBootDateread-onlymandatoryThe date and time of the last IPL of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.3Scalaref6000SysFirmwareVersionread-onlymandatoryThe current version of the firmware.
1.3.6.1.4.1.289.2.1.1.2.1.4Scalaref6000SysTypeNumread-onlymandatoryThe ASCII type number of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.5Scalaref6000SysModelNumread-onlymandatoryThe ASCII model number of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.6Scalaref6000SysMfgread-onlymandatoryThe ASCII manufacturer of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.7Scalaref6000SysPlantOfMfgread-onlymandatoryThe ASCII plant of manufacturer of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.8Scalaref6000SysEcLevelread-onlymandatoryThe ASCII EC level ID of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.9Scalaref6000SysSerialNumread-onlymandatoryThe ASCII system serial number of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.10Scalaref6000SysOperStatusread-onlymandatoryThe current operational status of the switch.
1.3.6.1.4.1.289.2.1.1.2.1.11Scalaref6000SysStateread-onlymandatoryIf the operational status of the switch is operational, the switch will be in one of the four states: online(1), coming-online(2), offline(3), and going-offlin…
1.3.6.1.4.1.289.2.1.1.2.1.12Scalaref6000SysAdmStatusread-writemandatoryThe desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The desired a…
1.3.6.1.4.1.289.2.1.1.2.1.13Scalaref6000SysConfigSpeedread-onlymandatorySwitch speed capability. It's a user initiated option to adjust the system-wide port speed capability.
1.3.6.1.4.1.289.2.1.1.2.2Nodeef6000Fru
1.3.6.1.4.1.289.2.1.1.2.2.1Tableef6000FruTablenot-accessiblemandatoryA table that contains one entry for each module.
1.3.6.1.4.1.289.2.1.1.2.2.1.1Rowef6000FruEntrynot-accessiblemandatoryAn entry containing the service parameters of the module.
1.3.6.1.4.1.289.2.1.1.2.2.1.1.1Columnef6000FruCoderead-onlymandatoryField Replaceable Unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code.
1.3.6.1.4.1.289.2.1.1.2.2.1.1.2Columnef6000FruPositionread-onlymandatoryThis object identifies the position of the module. The value starts from 1 to the maximum number of the cards that can be contained within this switch.
1.3.6.1.4.1.289.2.1.1.2.2.1.1.3Columnef6000FruStatusread-onlymandatoryThis object identifies the operational status of the module. The active(1) state indicates that the current module is active; The backup(2) state indicates tha…
1.3.6.1.4.1.289.2.1.1.2.2.1.1.4Columnef6000FruPartNumberread-onlymandatoryThe part number of the module.
1.3.6.1.4.1.289.2.1.1.2.2.1.1.5Columnef6000FruSerialNumberread-onlymandatoryThe serial number of the module.
1.3.6.1.4.1.289.2.1.1.2.2.1.1.6Columnef6000FruPowerOnHoursread-onlymandatoryThe number of the hours that the FRU has been in operation.
1.3.6.1.4.1.289.2.1.1.2.2.1.1.7Columnef6000FruTestDateread-onlymandatoryThe final test date of the module.
1.3.6.1.4.1.289.2.1.1.2.3Nodeef6000Port
1.3.6.1.4.1.289.2.1.1.2.3.1Tableef6000PortTablenot-accessiblemandatoryA table that contains one entry for each switch port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1Rowef6000PortEntrynot-accessiblemandatoryAn entry containing the information of the switch port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.1Columnef6000PortIndexread-onlymandatoryThe fixed physical port number on the switch. It ranges from 1 to the number of physical ports that can be supported in the switch.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.2Columnef6000PortPhyStateread-onlymandatoryThe physical state of the port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.3Columnef6000PortOpStatusread-onlymandatoryThe operational status of the port. The online(1) state indicates that user frames can be passed.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.4Columnef6000PortAdmStatusread-writemandatoryThe desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates th…
1.3.6.1.4.1.289.2.1.1.2.3.1.1.5Columnef6000PortConnectorread-onlymandatorySupported connector types of the port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.6Columnef6000PortDistanceread-onlymandatoryA bit map to represent distance types of the Port. bit 0 unknown bit 1-3 reserved bit 4 long distance (l) bit 5 intermediate distance (i) bit 6 short distance …
1.3.6.1.4.1.289.2.1.1.2.3.1.1.7Columnef6000PortTyperead-onlymandatorySupported transceiver types of the port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.8Columnef6000PortMediaread-onlymandatoryA bit map to represent transmission media of the port. bit 0 single mode (sm) bit 1 reserved bit 2 multi-mode, 50m (m5) bit 3 multi-mode, 62.5 (m6) bit 4-6 res…
1.3.6.1.4.1.289.2.1.1.2.3.1.1.9Columnef6000PortSpeedCapread-onlymandatoryA bit map to represent the speed of optical transceiver. bit 0 100 MBytes/Sec bit 1 reserved bit 2 200 MBytes/Sec bit 3 reserved bit 4 400 MBytes/Sec bit 5-7 r…
1.3.6.1.4.1.289.2.1.1.2.3.1.1.10Columnef6000PortConfigSpeedread-onlymandatoryThe configured port speed.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.11Columnef6000PortSpeedread-onlymandatoryThe current operating speed of the port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.20Columnef6000PortTxWords32read-onlymandatoryA 32 bit counter for the number of words within frames that the port has transmitted. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.21Columnef6000PortRxWords32read-onlymandatoryA 32 bit counter for the number of words within frames that the port has received. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.22Columnef6000PortTxFrames32read-onlymandatoryA 32 bit counter for the number of (Fibre Channel) frames that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.23Columnef6000PortRxFrames32read-onlymandatoryA 32 bit counter for the number of (Fibre Channel) frames that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.24Columnef6000PortTxThroughputread-onlymandatoryThe Bps (bytes per second) transmission rate of the port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.25Columnef6000PortRxThroughputread-onlymandatoryThe Bps (bytes per second) reception rate of the port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.30Columnef6000PortTxC2Words32read-onlymandatoryA 32 bit counter for the number of class 2 4-byte words that the port has transmitted. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.31Columnef6000PortRxC2Words32read-onlymandatoryA 32 bit counter for the number of class 2 4-byte words that the port has received. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.32Columnef6000PortTxC2Frames32read-onlymandatoryA 32 bit counter for the number of Class 2 frames that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.33Columnef6000PortRxC2Frames32read-onlymandatoryA 32 bit counter for the number of Class 2 frames that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.34Columnef6000PortTxC2Octets32read-onlymandatoryA 32 bit counter for the number of Class 2 Octets that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.35Columnef6000PortRxC2Octets32read-onlymandatoryA 32 bit counter for the number of Class 2 Octets that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.40Columnef6000PortTxC3Words32read-onlymandatoryA 32 bit counter for the number of class 3 4-byte words that the port has transmitted. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.41Columnef6000PortRxC3Words32read-onlymandatoryA 32 bit counter for the number of class 3 4-byte words that the port has received. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.42Columnef6000PortTxC3Frames32read-onlymandatoryA 32 bit counter for the number of Class 3 frames that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.43Columnef6000PortRxC3Frames32read-onlymandatoryA 32 bit counter for the number of Class 3 frames that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.44Columnef6000PortTxC3Octets32read-onlymandatoryA 32 bit counter for the number of Class 3 Octets that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.45Columnef6000PortRxC3Octets32read-onlymandatoryA 32 bit counter for the number of Class 3 Octets that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.46Columnef6000PortC3Discards32read-onlymandatoryA 32 bit counter for the number of Class 3 frames that the port has discarded.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.50Columnef6000PortDiscardFramesread-onlymandatoryThe number of frames that the port has discarded.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.51Columnef6000PortTxLinkResetsread-onlymandatoryThe number of link resets initiated by this switch port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.52Columnef6000PortRxLinkResetsread-onlymandatoryThe number of link resets initiated by the attached N_port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.53Columnef6000PortTxOLSsread-onlymandatoryThe number of offline sequences initiated by this switch port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.54Columnef6000PortRxOLSsread-onlymandatoryThe number of offline sequences initiated by the attached N_port.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.60Columnef6000PortSyncLossesread-onlymandatoryThe number of loss of synchronization timeout.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.61Columnef6000PortSigLossesread-onlymandatoryThe number of times that a Loss of Signal is detected.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.62Columnef6000PortProtocolErrorsread-onlymandatoryThe number of protocol errors detected.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.63Columnef6000PortInvalidTxWordsread-onlymandatoryThe number of Invalid Transmission words that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.64Columnef6000PortLinkFailuresread-onlymandatoryThe number of transitions to an LFx state.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.65Columnef6000PortCrcsread-onlymandatoryThe number of CRC errors detected from frames received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.66Columnef6000PortTruncsread-onlymandatoryThe number of frames shorter than the Fibre Channel minimum.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.67Columnef6000PortTxWords64read-onlymandatoryA 64 bit counter for the number of words within frames that the port has transmitted. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.68Columnef6000PortRxWords64read-onlymandatoryA 64 bit counter for the number of words within frames that the port has received. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.69Columnef6000PortTxFrames64read-onlymandatoryA 64 bit counter for the number of (Fibre Channel) frames that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.70Columnef6000PortRxFrames64read-onlymandatoryA 64 bit counter for the number of (Fibre Channel) frames that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.71Columnef6000PortTxC2Words64read-onlymandatoryA 64 bit counter for the number of class 2 4-byte words that the port has transmitted. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.72Columnef6000PortRxC2Words64read-onlymandatoryA 64 bit counter for the number of class 2 4-byte words that the port has received. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.73Columnef6000PortTxC2Frames64read-onlymandatoryA 64 bit counter for the number of Class 2 frames that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.74Columnef6000PortRxC2Frames64read-onlymandatoryA 64 bit counter for the number of Class 2 frames that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.75Columnef6000PortTxC2Octets64read-onlymandatoryA 64 bit counter for the number of Class 2 Octets that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.76Columnef6000PortRxC2Octets64read-onlymandatoryA 64 bit counter for the number of Class 2 Octets that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.77Columnef6000PortTxC3Words64read-onlymandatoryA 64 bit counter for the number of class 3 4-byte words that the port has transmitted. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.78Columnef6000PortRxC3Words64read-onlymandatoryA 64 bit counter for the number of class 3 4-byte words that the port has received. (Primitive signals and primitive sequence are not included.)
1.3.6.1.4.1.289.2.1.1.2.3.1.1.79Columnef6000PortTxC3Frames64read-onlymandatoryA 64 bit counter for the number of Class 3 frames that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.80Columnef6000PortRxC3Frames64read-onlymandatoryA 64 bit counter for the number of Class 3 frames that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.81Columnef6000PortTxC3Octets64read-onlymandatoryA 64 bit counter for the number of Class 3 Octets that the port has transmitted.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.82Columnef6000PortRxC3Octets64read-onlymandatoryA 64 bit counter for the number of Class 3 Octets that the port has received.
1.3.6.1.4.1.289.2.1.1.2.3.1.1.83Columnef6000PortC3Discards64read-onlymandatoryA 64 bit counter for the number of Class 3 frames that the port has discarded.
1.3.6.1.4.1.289.2.1.1.2.4Nodeef6000PortBinding
1.3.6.1.4.1.289.2.1.1.2.4.1Tableef6000PortBindingTablenot-accessiblemandatoryA table that contains one entry for each switch port.
1.3.6.1.4.1.289.2.1.1.2.4.1.1Rowef6000PortBindingEntrynot-accessiblemandatoryAn entry containing the port binding information of the switch port.
1.3.6.1.4.1.289.2.1.1.2.4.1.1.1Columnef6000PortBindingIndexread-onlymandatoryThe fixed physical port number on the switch. It ranges from 1 to the number of physical ports that can be supported in the switch.
1.3.6.1.4.1.289.2.1.1.2.4.1.1.2Columnef6000PortBindingFlagread-writemandatoryThe flag indicates whether or not Port Binding is in effect for an individual port.
1.3.6.1.4.1.289.2.1.1.2.4.1.1.3Columnef6000PortConfiguredWWNread-writemandatoryThe authorized port WWN for attached servers and storage systems (F ports), or the authorized switch WWN for attached switches (E ports).
1.3.6.1.4.1.289.2.1.1.2.4.1.1.4Columnef6000PortAttachedWWNread-onlymandatoryThe WWN of the device currently attached to the port whether it has successfully connected or is currently being rejected due to a Port Binding violation.
1.3.6.1.4.1.289.2.1.1.2.5Nodeef6000Zoning
1.3.6.1.4.1.289.2.1.1.2.5.1Scalaref6000ActiveZoneSetNameread-onlymandatoryThe active zone set name. This value will return NULL if the active zone set state is disabled
1.3.6.1.4.1.289.2.1.1.2.5.2Scalaref6000ActiveZoneCountread-onlymandatoryThe number of zones in the active zone set. This value will return 0 if the active zone set state is disabled
1.3.6.1.4.1.289.2.1.1.2.5.3Scalaref6000DefaultZoneSetStateread-onlymandatoryThe set state of the default zone set (1=Enabled,2= Disabled).
1.3.6.1.4.1.289.2.1.1.2.5.4Scalaref6000ActiveZoneSetStateread-onlymandatoryThe state of the active zone set. If the active zone set state is disabled, then ActiveZoneSetName and ActiveZoneSetCount are invalid (1=Enabled,2= Disabled).
1.3.6.1.4.1.289.2.1.1.2.5.5Scalaref6000HardwareEnforcedZoningread-onlymandatoryIndicates if zoning is hardware enforced (1=Yes, 2=No).
1.3.6.1.4.1.289.2.1.1.2.5.6Tableef6000ActiveZoneTablenot-accessiblemandatoryA table that contains one entry for each zone in the active zone set.
1.3.6.1.4.1.289.2.1.1.2.5.6.1Rowef6000ActiveZoneEntrynot-accessiblemandatoryAn entry containing the information specific to a zone.
1.3.6.1.4.1.289.2.1.1.2.5.6.1.1Columnef6000ZoneIndexread-onlymandatoryZone index number. This number will range from 1 to the number of zones specified by the ActiveZoneCount.
1.3.6.1.4.1.289.2.1.1.2.5.6.1.2Columnef6000ZoneNameread-onlymandatoryThis object is the name of this zone entry.
1.3.6.1.4.1.289.2.1.1.2.5.6.1.3Columnef6000ZoneMemberCountread-onlymandatoryThis object contains a count of the number of members in this zone entry.
1.3.6.1.4.1.289.2.1.1.2.5.7Tableef6000ActiveMemberTablenot-accessiblemandatoryA table that contains one entry for each member in the active zone set.
1.3.6.1.4.1.289.2.1.1.2.5.7.1Rowef6000ActiveMemberEntrynot-accessiblemandatoryAn entry containing the information specific to a member.
1.3.6.1.4.1.289.2.1.1.2.5.7.1.1Columnef6000MemberZoneIndexread-onlymandatoryThe index of the zone that this member belongs to. This is the same value as ef6000ZoneIndex.
1.3.6.1.4.1.289.2.1.1.2.5.7.1.2Columnef6000MemberIndexread-onlymandatoryMember index number. This number will range from 1 to the number of members specified by the corresponding ZoneMemberCount.
1.3.6.1.4.1.289.2.1.1.2.5.7.1.3Columnef6000MemberTyperead-onlymandatoryThis object is the type of addressing that is associated with this member.
1.3.6.1.4.1.289.2.1.1.2.5.7.1.4Columnef6000MemberWWNread-onlymandatoryThe WWN name as an 8-octet string. This value is only valid if the member type is 1, otherwise it will return all zeros.
1.3.6.1.4.1.289.2.1.1.2.5.7.1.5Columnef6000MemberDomainIDread-onlymandatoryThe domain ID. This value is only valid if the member type is 2, otherwise it will return NULL.
1.3.6.1.4.1.289.2.1.1.2.5.7.1.6Columnef6000MemberPortNumberread-onlymandatoryThe port number. This value is only valid if the member type is 2, otherwise it will return NULL.
1.3.6.1.4.1.289.2.1.1.2.6Nodeef6000TA
1.3.6.1.4.1.289.2.1.1.2.6.1Tableef6000TATablenot-accessiblemandatoryA table that contains one entry for each configured threshold alert.
1.3.6.1.4.1.289.2.1.1.2.6.1.1Rowef6000TAEntrynot-accessiblemandatoryAn entry containing a threshold alert configuration.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.1Columnef6000TAIndexread-onlymandatoryThis object is used to identify which threshold has been triggered.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.2Columnef6000TANameread-onlymandatoryThe threshold alert name.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.3Columnef6000TAStateread-onlymandatoryThe current state of the threshold.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.4Columnef6000TATyperead-onlymandatoryThe type of the threshold.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.5Columnef6000TAPortTyperead-onlymandatoryA threshold can be set on a list of physical port numbers or on all the ports of the specified type (ePorts, fPorts).
1.3.6.1.4.1.289.2.1.1.2.6.1.1.6Columnef6000TAPortListread-onlymandatoryA bit map that identifies which ports this threhold alert applies to (only valid if the Threshold Alert Port Type = list). The left most bit represents the por…
1.3.6.1.4.1.289.2.1.1.2.6.1.1.7Columnef6000TAIntervalread-onlymandatoryThe number of minutes in a threshold alert interval.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.8Columnef6000TATriggerValueread-onlymandatoryIf the alert type is a Throughput Threshold Alert, then this is the percent utilization (1-100) required to trigger an alert. If the alert type is a Counter Th…
1.3.6.1.4.1.289.2.1.1.2.6.1.1.9Columnef6000TTADirectionread-onlymandatoryThis only applies when the alert type is a Throughput Threshold Alert. It specifies the throughput direction of the threshold.
1.3.6.1.4.1.289.2.1.1.2.6.1.1.10Columnef6000TTATriggerDurationread-onlymandatoryThis only applies when the alert type is a Throughput Threshold Alert. It specifies the amount of time during a threshold alert interval that the trigger must …
1.3.6.1.4.1.289.2.1.1.2.6.1.1.11Columnef6000CTACounterread-onlymandatoryThis only applies when the alert type is a Counter Threshold Alert. It specifies statistical counter or counter set to be monitored. (This object is not suppor…
1.3.6.1.4.1.289.3Nodeef6000PortBindingViolationAn ef6000PortBindingViolation(3) is generated whenever the switch detects that a port binding violation occurs.
1.3.6.1.4.1.289.4Nodeef6000ThresholdAlertAn ef6000ThresholdAlert(4) is generated whenever a threshold alert occurs.
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING
Ef6000FruCodeINTEGER { fru-bkplane (1) , fru-ctp (2) , fru-sbar (3) , fru-fan2 (4) , fru-fan (5) , fru-power (6) , fru-reserved (7) , fru-glsl (8) , fru-gsml (9) , fru-gxxl (10), fru-gsf1 (11), fru-gsf2 (12), fru-glsr (13), fru-gsmr (14), fru-gxxr (15), fru-fint1 (16) }
Ef6000FruPositionINTEGER (1..255)
Ef6000PortIndexINTEGER (1..2048)
Ef6000PortListOCTET STRING (SIZE (32))
Ef6000PortPhyStateINTEGER { psNotInstalled (1), psAvailable (2), psBlocked (3), psUnavailable (4), psLinkFailure (5), psLinkFailLOL (6), psIntDiags (7), psExtLoop (8), psPortFail (9), psSR (10), psLR (11), psInaccessible (12), psInactive (13) }
Ef6000PortWWNOCTET STRING (SIZE (8))
Ef6000SysOperStatusINTEGER { operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5) }