EICON-MIB-TRACE
39 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.434 | Nodeeicon | |||
| 1.3.6.1.4.1.434.2 | Nodemanagement | |||
| 1.3.6.1.4.1.434.2.2 | Nodemibv2 | |||
| 1.3.6.1.4.1.434.2.2.4 | Nodemodule | |||
| 1.3.6.1.4.1.434.2.2.4.15 | Nodetrace | |||
| 1.3.6.1.4.1.434.2.2.4.15.1 | ScalartraceFreeEntryIndex | read-only | mandatory | The number indicating to the Manager the first available index for the new Entry in the traceTable. The Manager will first get this value from the Agent and th… |
| 1.3.6.1.4.1.434.2.2.4.15.2 | TabletraceControlTable | not-accessible | mandatory | Trace control paramters table, one row per port. All parameters in this table have read-write access and have to be set before the trace can be started. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1 | RowtraceControlEntry | not-accessible | mandatory | The set of attributes for each port. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.1 | ColumntraceCntrlIndex | read-only | mandatory | Index of the table |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.2 | ColumntraceCntrlEntryStatus | read-write | mandatory | Status of this entry in the table |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.3 | ColumntraceCntrlEntryOwner | read-write | mandatory | Owner of entry |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.4 | ColumntraceCntrlProtocol | read-write | mandatory | The Protocol to trace |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.5 | ColumntraceCntrlEntryReclaimTime | read-write | mandatory | This is the amount of time the the entry is valid. a value of 0 means valid forever. default is 1 day ticks |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.6 | ColumntraceCntrlOnOff | read-write | mandatory | The start/stop parameter |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.7 | ColumntraceCntrlActionState | read-only | mandatory | Result of the Trace start operation. Management Station should read this value after starting the trace to find it's status. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.8 | ColumntraceCntrlActionError | read-only | mandatory | The error codes if traceStartResult has start-failed |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.9 | ColumntraceCntrlFileName | read-write | mandatory | The trace file name (full). Has to be provided by the Operator. The Agent will create the file traceFileName. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.10 | ColumntraceCntrlCardRef | read-write | mandatory | The EiconCard Reference if the traced protocol requires a card reference. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.11 | ColumntraceCntrlPortRef | read-write | mandatory | The pointer to the port, the same as hdlcParmPortRef from the hdlcParmTable. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.12 | ColumntraceCntrlConnectionRef | read-write | mandatory | Connection Id reference, for Transport and Frame Relay. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.13 | ColumntraceCntrlPURef | read-write | mandatory | PU name for SNA PC. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.14 | ColumntraceCntrlModeRef | read-write | mandatory | Mode reference name for SNA APPC. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.15 | ColumntraceCntrlLURef | read-write | mandatory | LU reference for SNA PC |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.16 | ColumntraceCntrlStationRef | read-write | mandatory | Station reference for SDLC |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.17 | ColumntraceCntrlLLURef | read-write | mandatory | LLU reference. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.18 | ColumntraceCntrlRLURef | read-write | mandatory | RLU reference. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.19 | ColumntraceCntrlOption | read-write | mandatory | The option to reset the trace buffer |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.20 | ColumntraceCntrlPeriod | read-write | mandatory | The time period for the trace, in seconds |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.21 | ColumntraceCntrlMask | read-write | mandatory | The filter for the EiconCard trace function. The value has to be OR-ed using the following components, specific for each protocol. hdlc,sdlc: nothing (0), fram… |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.22 | ColumntraceCntrlBufSize | read-write | mandatory | The size of the trace buffer on the EiconCard |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.23 | ColumntraceCntrlEntrySize | read-write | mandatory | The buffer entry truncation length. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.24 | ColumntraceCntrlBufFullAction | read-write | mandatory | The buffer-full action of the EiconCard, wrap or stop and alarm. Only wrap is implemented in this first version. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.25 | ColumntraceCntrlReadFromEntryIndex | read-write | mandatory | This parameter is used to indicate to the EiconCard trace function the position in the buffer when reading the trace buffer. Used with the GET for traceTable. |
| 1.3.6.1.4.1.434.2.2.4.15.2.1.26 | ColumntraceCntrlFileType | read-write | mandatory |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| ActionState | INTEGER { done (1), failed (2), in-progress (3) } | ||
| CardRef | INTEGER (1..6) | ||
| ControlOnOff | INTEGER { stop (1), start (2), invalid (3) } | ||
| PortRef | INTEGER (1..48) | ||
| PositiveInteger | INTEGER (0..2147483647) |