EKINOPS-MGNT2-MIB
532 objects
MIB for Ekinops 360 management.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiLoadGWSW EkiLoadPermutMethod EkiLoadPermutMode EkiLoadState ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString RowStatus TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.7 | Identitymgnt2 | MIB for Ekinops 360 management. | ||
| 1.3.6.1.4.1.20044.7.1 | Nodemgnt2SNMPAgentData | |||
| 1.3.6.1.4.1.20044.7.1.1 | Nodemgnt2IPmanagment | |||
| 1.3.6.1.4.1.20044.7.1.1.1 | Tablemgnt2GigmManagerIpAddressTable | not-accessible | current | Manager IP address Table. |
| 1.3.6.1.4.1.20044.7.1.1.1.1 | Rowmgnt2GigmManagerIpAddressEntry | not-accessible | current | |
| 1.3.6.1.4.1.20044.7.1.1.1.1.1 | Columnmgnt2GigmManagerIpIndex | read-create | current | Index of the IP address of the manager |
| 1.3.6.1.4.1.20044.7.1.1.1.1.2 | Columnmgnt2GigmManagerIpAddress | read-create | current | IP address of the manager:This OID defines the IP address of the SNMP Manager attached to the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.1.1.1.3 | Columnmgnt2GigmManagerIpAddressTableRowStatus | read-create | current | The status of this row. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.4 | Columnmgnt2GigmManagerTrapPort | read-create | current | Manager UDP port. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.5 | Columnmgnt2GigmManagerEnableCtrl | read-create | current | Enabling trap of Ctrl. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.6 | Columnmgnt2GigmManagerEnableConfig | read-create | current | Enabling trap of config. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.7 | Columnmgnt2GigmManagerEnableEvent | read-create | current | Enabling trap of event. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.8 | Columnmgnt2GigmManagerEnableAlarmCrit | read-create | current | Enabling trap of crit alarm. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.9 | Columnmgnt2GigmManagerEnableAlarmMajor | read-create | current | Enabling trap of major alarm. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.10 | Columnmgnt2GigmManagerEnableAlarmMinor | read-create | current | Enabling trap of minor alarm. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.11 | Columnmgnt2GigmManagerRegistrationTimeout | read-create | current | Time-out for manager activities. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.12 | Columnmgnt2GigmManagerEnableAlarmWarning | read-create | current | Enabling trap of warning alarm. |
| 1.3.6.1.4.1.20044.7.1.1.1.1.13 | Columnmgnt2GigmManagerEnableAlarmIndeterminate | read-create | current | Enabling trap of indeterminate alarm. |
| 1.3.6.1.4.1.20044.7.1.1.2 | Scalarmgnt2GigmBoardIpAddress | read-write | current | IP address of the Chassis:This OID defines the IP address of the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.1.3 | Scalarmgnt2GigmIPAddresByDHCP | read-write | current | IP address retrieved by DHCP:If enabled, the IP address is retrieved by DHCP, in which case changes take effect after a board reset. If disabled the object, mg… |
| 1.3.6.1.4.1.20044.7.1.1.4 | Scalarmgnt2GigmNetmask | read-write | current | Netmask for the board IP address:This OID defined the IP Subnet mask of the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.1.5 | Tablemgnt2GigmGatewayAddressTable | not-accessible | current | Gateway IP address Table: This table contains all the gateway IP addresses. |
| 1.3.6.1.4.1.20044.7.1.1.5.1 | Rowmgnt2GigmGatewayAddressEntry | not-accessible | current | |
| 1.3.6.1.4.1.20044.7.1.1.5.1.1 | Columnmgnt2GigmGatewayIndex | read-create | current | Index of the IP address of the gateway |
| 1.3.6.1.4.1.20044.7.1.1.5.1.2 | Columnmgnt2GigmGatewayAddress | read-create | current | IP address of the gateway :This OID defines the IP address of the gateway attached to the Chassis |
| 1.3.6.1.4.1.20044.7.1.1.5.1.3 | Columnmgnt2GigmGatewayOrder | read-create | current | Gateway priority: This OID defines the priority of the gateway (lower number for higher priority) |
| 1.3.6.1.4.1.20044.7.1.1.6 | Scalarmgnt2GigmSyslog | read-write | current | IP address of the syslog server:This OID defines the IP address of the syslog of the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.1.7 | Scalarmgnt2GigmNtpServer | read-write | current | IP address of the ntp server:This OID defines the IP address of the ntp server for the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.1.8 | Scalarmgnt2GigmNodeIpAddress | read-write | current | Node IP address :This OID defines the Node IP address in node controller mode for the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.1.9 | Scalarmgnt2GigmOspfNetworkPortIpAddress | read-write | current | OSPF Network Port IP address :This OID defines the OSPF Network Port IP address used to reach Node through external interface |
| 1.3.6.1.4.1.20044.7.1.1.10 | Scalarmgnt2GigmOspfUnnumberedSubnet | read-write | current | OSPF Unnumbered subnet:This OID defines the subnet of the unnumbered IP inside the instance in the OSPF area |
| 1.3.6.1.4.1.20044.7.1.1.11 | Scalarmgnt2GigmOspfPassword | read-write | current | Shared password for Ospf:This OID defines the shared password of the OSPF area |
| 1.3.6.1.4.1.20044.7.1.1.12 | Scalarmgnt2GigmOspfFrontRouterIpAddress | read-write | current | OSPF Front Router IP address :This OID defines the OSPF Front Router IP address used for migration to reach RSTP node through OSC interface |
| 1.3.6.1.4.1.20044.7.1.1.13 | Scalarmgnt2GigmOspfRouterId | read-write | current | OSPF Router ID :This OID defines the OSPF Router ID used in chassis for OSPF routes. |
| 1.3.6.1.4.1.20044.7.1.1.14 | Scalarmgnt2GigmOspfSecondIpAddress | read-write | current | OSPF Second IP address :This OID defines the OSPF Second IP address used by backup network |
| 1.3.6.1.4.1.20044.7.1.2 | Nodemgnt2ModulesManagement | |||
| 1.3.6.1.4.1.20044.7.1.2.1 | Tablemgnt2GigmBoardTable | not-accessible | current | List of PMs plugged in the Chassis |
| 1.3.6.1.4.1.20044.7.1.2.1.1 | Rowmgnt2GigmBoardEntry | not-accessible | current | Row Definition for the PMs table |
| 1.3.6.1.4.1.20044.7.1.2.1.1.1 | Columnmgnt2IndexBoards | read-only | current | Index for PMs table |
| 1.3.6.1.4.1.20044.7.1.2.1.1.2 | Columnmgnt2Position | read-only | current | PM Slot number:This OID gives the slot number in which the PM is plugged |
| 1.3.6.1.4.1.20044.7.1.2.1.1.3 | Columnmgnt2Name | read-only | current | PM name:This OID gives the name of the PM plugged in the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.2.1.1.4 | Columnmgnt2PortNumber | read-only | current | Number of Client Ports:This OID gives the number of client ports on the PM plugged in the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.2.1.1.5 | Columnmgnt2LineNumber | read-only | current | Number of Line Ports:This OID gives the number of line ports on the PM plugged in the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.2.1.1.6 | Columnmgnt2GroupNumber | read-only | current | Number of Groups:This OID gives the number of group of clients on the PM plugged in the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.2.1.1.7 | Columnmgnt2RootOIDInventory | read-only | current | root oid of the inventory leaf of the corresponding PM |
| 1.3.6.1.4.1.20044.7.1.2.1.1.8 | Columnmgnt2SlotOcc | read-only | current | PM Slot occupied:This OID gives the slots taken by this PM |
| 1.3.6.1.4.1.20044.7.1.2.1.1.9 | Columnmgnt2SubFunctionLabel | read-only | current | Sub Function Label: This OID gives the name of the sub function embedded on the Chassis. (applied only on the 100G Chassis) |
| 1.3.6.1.4.1.20044.7.1.2.1.1.10 | Columnmgnt2SlotStatus | read-only | current | Slot Status: This OID gives the status of the slot in the Chassis: See Textual COnvention |
| 1.3.6.1.4.1.20044.7.1.2.7 | Scalarmgnt2GigmSelectedBoard | read-write | current | PM Slot number selected:PM selected for further operations in the Ekinops module board tree. This number is the slot number. |
| 1.3.6.1.4.1.20044.7.1.4 | Tablemgnt2GigmMibsTable | not-accessible | obsolete | List of MIBs supported by the Chassis SNMPAgent |
| 1.3.6.1.4.1.20044.7.1.4.1 | Rowmgnt2GigmMibsEntry | not-accessible | obsolete | Row definition for MIBs table |
| 1.3.6.1.4.1.20044.7.1.4.1.1 | Columnmgnt2IndexMibs | read-only | obsolete | Index for MIBs table |
| 1.3.6.1.4.1.20044.7.1.4.1.2 | Columnmgnt2MibName | read-only | obsolete | MIB name:This OID gives the name of the MIBs supported by the SNMP Agent |
| 1.3.6.1.4.1.20044.7.1.4.1.3 | Columnmgnt2MibPartNumber | read-only | obsolete | MIB Part Number:This OID gives the part number of the MIBs supported by the SNMP Agent |
| 1.3.6.1.4.1.20044.7.1.5 | Scalarmgnt2GigmLogicalName | read-write | current | Mgnt2 name:This OID defines the name of the Mgnt2 |
| 1.3.6.1.4.1.20044.7.1.6 | Scalarmgnt2GigmEqptType | read-only | current | Equipment type:This OID defines the type of the Equipment |
| 1.3.6.1.4.1.20044.7.1.7 | Nodemgnt2GigmTrapCount | |||
| 1.3.6.1.4.1.20044.7.1.7.1 | Scalarmgnt2GigmTrapCounter | read-only | current | Trap counter:This OID counts the number of trap sent |
| 1.3.6.1.4.1.20044.7.1.7.2 | Scalarmgnt2GigmResetTrapCounter | read-write | current | Reset trap counter:This OID reset the trap counter to 0 |
| 1.3.6.1.4.1.20044.7.1.8 | Nodemgnt2GigmSecurity | |||
| 1.3.6.1.4.1.20044.7.1.8.1 | Scalarmgnt2GigmRoCommunity | read-write | current | SNMP Get community:This OID defines the community for the SNMP Get function |
| 1.3.6.1.4.1.20044.7.1.8.2 | Scalarmgnt2GigmRwCommunity | read-write | current | SNMP Set community:This OID defines the community for the SNMP Set function |
| 1.3.6.1.4.1.20044.7.1.8.3 | Scalarmgnt2GigmTrapCommunity | read-write | current | SNMP Trap community:This OID defines the community for the SNMP Trap function |
| 1.3.6.1.4.1.20044.7.1.9 | Nodemgnt2GigmTime | |||
| 1.3.6.1.4.1.20044.7.1.9.1 | Scalarmgnt2GigmCurrentHour | read-write | current | Chassis Hour time:This OID defines the hour of the chassis' time |
| 1.3.6.1.4.1.20044.7.1.9.2 | Scalarmgnt2GigmCurrentMinute | read-write | current | Chassis Minute time:This OID defines the minute of the chassis' time |
| 1.3.6.1.4.1.20044.7.1.9.3 | Scalarmgnt2GigmCurrentYear | read-write | current | Chassis year date:This OID defines the year of the chassis' date |
| 1.3.6.1.4.1.20044.7.1.9.4 | Scalarmgnt2GigmCurrentMonth | read-write | current | Chassis month date:This OID defines the month of the chassis' date |
| 1.3.6.1.4.1.20044.7.1.9.5 | Scalarmgnt2GigmCurrentDay | read-write | current | Chassis day date:This OID defines the day of the chassis' date |
| 1.3.6.1.4.1.20044.7.1.10 | Nodemgnt2Authentication | |||
| 1.3.6.1.4.1.20044.7.1.10.1 | Scalarmgnt2GigmRadiusServer | read-write | current | IP address of the RADIUS server:This OID defines the IP address of the external RADIUS server for authentication |
| 1.3.6.1.4.1.20044.7.1.10.2 | Scalarmgnt2GigmRadiusPort | read-write | current | UDP port number of the RADIUS server:This OID defines the UDP port number of the external RADIUS server for authentication |
| 1.3.6.1.4.1.20044.7.1.10.3 | Scalarmgnt2GigmRadiusSecret | read-write | current | Shared secret of the RADIUS server:This OID defines the shared secret password of the RADIUS server for authentication |
| 1.3.6.1.4.1.20044.7.1.10.4 | Scalarmgnt2GigmLdapHost | read-write | deprecated | IP address of the LDAP host:This OID defines the IP address of the external LDAP server for authentication |
| 1.3.6.1.4.1.20044.7.1.10.5 | Scalarmgnt2GigmLdapPort | read-write | deprecated | UDP port number of the LDAP server:This OID defines the UDP port number of the external LDAP server for authentication |
| 1.3.6.1.4.1.20044.7.1.10.6 | Scalarmgnt2GigmLdapBase | read-write | deprecated | LDAP base:This OID defines the name of the search base of the LDAP server for authentication<Help>LDAP base name spelled as follows: 'ou=users,ou=network,dc=yo… |
| 1.3.6.1.4.1.20044.7.1.10.7 | Scalarmgnt2GigmLdapVersion | read-write | deprecated | Protocol number in use by the LDAP server:This OID defines the protocol version used by the external LDAP server for authentication<Help>Protocol version used … |
| 1.3.6.1.4.1.20044.7.1.10.8 | Scalarmgnt2GigmLdapBindDn | read-write | deprecated | LDAP Bind DN:This OID defines the login name used to connect into the LDAP server base for authentication<Help>LDAP binddn spelled as follows: 'cn=ldap_admin,d… |
| 1.3.6.1.4.1.20044.7.1.10.9 | Scalarmgnt2GigmLdapBindPw | read-write | deprecated | Credentials to bind the LDAP server with:This OID defines the credentials to bind the LDAP server with for authentication<Help>Credentials for LDAP access (bin… |
| 1.3.6.1.4.1.20044.7.1.10.10 | Scalarmgnt2GigmLdapScope | read-write | deprecated | Scope for LDAP base search:This OID defines the search scope for an LDAP base search <Help>LDAP search scope |
| 1.3.6.1.4.1.20044.7.1.10.11 | Scalarmgnt2GigmLdapPamPasswd | read-write | deprecated | PAM password handling:This OID defines the way the PAM password is handled for LDAP authentication <Help>The 'pam_password' option sould be one of the followin… |
| 1.3.6.1.4.1.20044.7.1.10.12 | Scalarmgnt2GigmAuthenticationType | read-write | current | Authentication type in use |
| 1.3.6.1.4.1.20044.7.2 | Nodemgnt2Hardware | |||
| 1.3.6.1.4.1.20044.7.2.1 | Nodemgnt2alarms | |||
| 1.3.6.1.4.1.20044.7.2.1.0 | Nodemgnt2AlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.7.2.1.0.7 | Scalarmgnt2AlmChassisTempAlm | read-only | current | Chassis Temperature Alarm :This OID indicates that the chassis temperature reached an alarm threshold <Help> This alarm indicates that the temperature of the c… |
| 1.3.6.1.4.1.20044.7.2.1.0.8 | Scalarmgnt2AlmChassisTempWarn | read-only | current | Chassis Temperature Warning :This OID indicates that the chassis temperature reached a warning threshold <Help> This warning indicates that the temperature of … |
| 1.3.6.1.4.1.20044.7.2.1.0.9 | Scalarmgnt2AlmAbsFailure | read-only | current | Chassis Management Module Failure :This OID indicates that the Chassis Management module is in fail condition <Condtype> ABS_FAILURE <Probcause> other(1) <Alar… |
| 1.3.6.1.4.1.20044.7.2.1.0.10 | Scalarmgnt2AlmFansFailure | read-only | current | Chassis Fan Module Failure :This OID indicates that at least one of the three FAN unit of the FAN module is in fail condition <Condtype> FANS_FAILURE <Probcaus… |
| 1.3.6.1.4.1.20044.7.2.1.0.11 | Scalarmgnt2AlmDef48a | read-only | current | Power Input A Fail :This OID indicates that there is not input power on the right power connector (A) <Help> This alarm indicates if the power input A is prese… |
| 1.3.6.1.4.1.20044.7.2.1.0.12 | Scalarmgnt2AlmDef48b | read-only | current | Power Input B Fail :This OID indicates that there is not input power on the right power connector (B) <Help> This alarm indicates if the power input B is prese… |
| 1.3.6.1.4.1.20044.7.2.1.0.15 | Scalarmgnt2AlmMgntDefFuseA | read-only | current | Management Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Management board <Help> Status of the Management Fuse… |
| 1.3.6.1.4.1.20044.7.2.1.0.16 | Scalarmgnt2AlmMgntDefFuseB | read-only | current | Management Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Management board <Help> Status of the Management Fuse… |
| 1.3.6.1.4.1.20044.7.2.1.1 | Nodemgnt2AlmsynthAlm1 | |||
| 1.3.6.1.4.1.20044.7.2.1.1.1 | Scalarmgnt2AlmNurgVisual | read-only | current | Minor Chassis Alarm :This OID indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates … |
| 1.3.6.1.4.1.20044.7.2.1.1.2 | Scalarmgnt2AlmUrgVisual | read-only | current | Major Chassis Alarm :This OID indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indicates … |
| 1.3.6.1.4.1.20044.7.2.1.1.3 | Scalarmgnt2AlmCritVisual | read-only | current | Critical Chassis Alarm :This OID indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) <Help> This alarm indi… |
| 1.3.6.1.4.1.20044.7.2.1.1.16 | Scalarmgnt2AlmAcknowledge | read-only | current | Alarm Ack. :This OID indicates the alarms have been acknowledged by the user (locally or remotely) <Help> This status indicates the alarms have been acknowledg… |
| 1.3.6.1.4.1.20044.7.2.1.16 | Nodemgnt2AlmboardMgmntSet1 | |||
| 1.3.6.1.4.1.20044.7.2.1.16.2 | Scalarmgnt2AlmPmSlot1Absent | read-only | current | PM Absent In Chassis Slot 1 :This OID indicates the presence of a PM in Slot 1 of the Chassis . <Help> This status indicates if a PM is detected in slot 1 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.3 | Scalarmgnt2AlmPmSlot2Absent | read-only | current | PM Absent In Chassis Slot 2 :This OID indicates the presence of a PM in Slot 2 of the Chassis . <Help> This status indicates if a PM is detected in slot 2 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.4 | Scalarmgnt2AlmPmSlot3Absent | read-only | current | PM Absent In Chassis Slot 3 :This OID indicates the presence of a PM in Slot 3 of the Chassis . <Help> This status indicates if a PM is detected in slot 3 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.5 | Scalarmgnt2AlmPmSlot4Absent | read-only | current | PM Absent In Chassis Slot 4 :This OID indicates the presence of a PM in Slot 4 of the Chassis . <Help> This status indicates if a PM is detected in slot 4 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.6 | Scalarmgnt2AlmPmSlot5Absent | read-only | current | PM Absent In Chassis Slot 5 :This OID indicates the presence of a PM in Slot 5 of the Chassis . <Help> This status indicates if a PM is detected in slot 5 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.7 | Scalarmgnt2AlmPmSlot6Absent | read-only | current | PM Absent In Chassis Slot 6 :This OID indicates the presence of a PM in Slot 6 of the Chassis . <Help> This status indicates if a PM is detected in slot 6 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.8 | Scalarmgnt2AlmPmSlot7Absent | read-only | current | PM Absent In Chassis Slot 7 :This OID indicates the presence of a PM in Slot 7 of the Chassis . <Help> This status indicates if a PM is detected in slot 7 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.9 | Scalarmgnt2AlmPmSlot8Absent | read-only | current | PM Absent In Chassis Slot 8 :This OID indicates the presence of a PM in Slot 8 of the Chassis . <Help> This status indicates if a PM is detected in slot 8 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.10 | Scalarmgnt2AlmPmSlot9Absent | read-only | current | PM Absent In Chassis Slot 9 :This OID indicates the presence of a PM in Slot 9 of the Chassis . <Help> This status indicates if a PM is detected in slot 9 <Con… |
| 1.3.6.1.4.1.20044.7.2.1.16.11 | Scalarmgnt2AlmPmSlot10Absent | read-only | current | PM Absent In Chassis Slot 10 :This OID indicates the presence of a PM in Slot 10 of the Chassis . <Help> This status indicates if a PM is detected in slot 10 <… |
| 1.3.6.1.4.1.20044.7.2.1.16.12 | Scalarmgnt2AlmPmSlot11Absent | read-only | current | PM Absent In Chassis Slot 11 :This OID indicates the presence of a PM in Slot 11 of the Chassis . <Help> This status indicates if a PM is detected in slot 11 <… |
| 1.3.6.1.4.1.20044.7.2.1.16.14 | Scalarmgnt2AlmPmFanAbsent | read-only | current | Fan Module Absent in Chassis :This OID indicates the presence of the FAN module in the Chassis. <Help> This alarm indicates if the Fan module is detected in th… |
| 1.3.6.1.4.1.20044.7.2.1.17 | Nodemgnt2AlmboardMgmntSet2 | |||
| 1.3.6.1.4.1.20044.7.2.1.17.1 | Scalarmgnt2AlmPmSlot12Absent | read-only | current | PM Absent In Chassis Slot 12 :This OID indicates the presence of a PM in Slot 12 of the Chassis . <Help> This status indicates if a PM is detected in slot 12 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.2 | Scalarmgnt2AlmPmSlot13Absent | read-only | current | PM Absent In Chassis Slot 13 :This OID indicates the presence of a PM in Slot 13 of the Chassis . <Help> This status indicates if a PM is detected in slot 13 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.3 | Scalarmgnt2AlmPmSlot14Absent | read-only | current | PM Absent In Chassis Slot 14 :This OID indicates the presence of a PM in Slot 14 of the Chassis . <Help> This status indicates if a PM is detected in slot 14 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.4 | Scalarmgnt2AlmPmSlot15Absent | read-only | current | PM Absent In Chassis Slot 15 :This OID indicates the presence of a PM in Slot 15 of the Chassis . <Help> This status indicates if a PM is detected in slot 15 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.5 | Scalarmgnt2AlmPmSlot16Absent | read-only | current | PM Absent In Chassis Slot 16 :This OID indicates the presence of a PM in Slot 16 of the Chassis . <Help> This status indicates if a PM is detected in slot 16 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.6 | Scalarmgnt2AlmPmSlot17Absent | read-only | current | PM Absent In Chassis Slot 17 :This OID indicates the presence of a PM in Slot 17 of the Chassis . <Help> This status indicates if a PM is detected in slot 17 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.7 | Scalarmgnt2AlmPmSlot18Absent | read-only | current | PM Absent In Chassis Slot 18 :This OID indicates the presence of a PM in Slot 18 of the Chassis . <Help> This status indicates if a PM is detected in slot 18 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.8 | Scalarmgnt2AlmPmSlot19Absent | read-only | current | PM Absent In Chassis Slot 19 :This OID indicates the presence of a PM in Slot 19 of the Chassis . <Help> This status indicates if a PM is detected in slot 19 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.9 | Scalarmgnt2AlmPmSlot20Absent | read-only | current | PM Absent In Chassis Slot 20 :This OID indicates the presence of a PM in Slot 20 of the Chassis . <Help> This status indicates if a PM is detected in slot 20 <… |
| 1.3.6.1.4.1.20044.7.2.1.17.10 | Scalarmgnt2AlmPmSlot21Absent | read-only | current | PM Absent In Chassis Slot 21 :This OID indicates the presence of a PM in Slot 21 of the Chassis .<Help> This status indicates if a PM is detected in slot 21 <C… |
| 1.3.6.1.4.1.20044.7.2.1.17.11 | Scalarmgnt2AlmPmSlot22Absent | read-only | current | PM Absent In Chassis Slot 22 :This OID indicates the presence of a PM in Slot 22 of the Chassis .<Help> This status indicates if a PM is detected in slot 22 <C… |
| 1.3.6.1.4.1.20044.7.2.1.17.12 | Scalarmgnt2AlmPmSlot23Absent | read-only | current | PM Absent In Chassis Slot 23 :This OID indicates the presence of a PM in Slot 23 of the Chassis .<Help> This status indicates if a PM is detected in slot 23 <C… |
| 1.3.6.1.4.1.20044.7.2.1.17.13 | Scalarmgnt2AlmPmSlot24Absent | read-only | current | PM Absent In Chassis Slot 24 :This OID indicates the presence of a PM in Slot 24 of the Chassis .<Help> This status indicates if a PM is detected in slot 24 <C… |
| 1.3.6.1.4.1.20044.7.2.1.20 | Nodemgnt2AlmfanMgmnt | |||
| 1.3.6.1.4.1.20044.7.2.1.20.2 | Scalarmgnt2AlmPbFan1Fail | read-only | current | Fan Unit #1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.7.2.1.20.3 | Scalarmgnt2AlmPbFan2Fail | read-only | current | Fan Unit #2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.7.2.1.20.4 | Scalarmgnt2AlmPbFan3Fail | read-only | current | Fan Unit #3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.7.2.1.20.5 | Scalarmgnt2AlmPbFan4Fail | read-only | current | Fan Unit #4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.7.2.1.20.6 | Scalarmgnt2AlmPbFan5Fail | read-only | current | Fan Unit #5 Failed On Fan Module :This OID indicates a failure on fan 5. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.7.2.1.20.7 | Scalarmgnt2AlmPbFan6Fail | read-only | current | Fan Unit #6 Failed On Fan Module :This OID indicates a failure on fan 6. Removal of the fan unit or no rotation sets the OID. <Help> This alarm indicates if th… |
| 1.3.6.1.4.1.20044.7.2.1.20.15 | Scalarmgnt2AlmWbFanFail | read-only | current | Fan Fail :This OID indicates a failure on one of the fans . <Help> This alarm indicates if one of the fans is in fail condition <Condtype> WB_FAN_FAIL <Probcau… |
| 1.3.6.1.4.1.20044.7.2.1.20.16 | Scalarmgnt2AlmFanFilterAbsent | read-only | current | Dust Filter Absent :This OID indicates that the dust filter is not present<Help> This alarm indicates if the Dust Filter is detected in the chassis. <Condtype>… |
| 1.3.6.1.4.1.20044.7.2.1.21 | Nodemgnt2AlmrackMgmnt | |||
| 1.3.6.1.4.1.20044.7.2.1.21.9 | Scalarmgnt2AlmChassisTempHiAlm | read-only | current | Chassis Temperature High Alarm :This OID indicates that the chassis temperature rose above the alarm threshold (+55C) <Help> This alarm indicates that the temp… |
| 1.3.6.1.4.1.20044.7.2.1.21.10 | Scalarmgnt2AlmChassisTempLoAlm | read-only | current | Chassis Temperature Low Alarm :This OID indicates that the chassis temperature dropped below the alarm threshold (-5C) <Help> This alarm indicates that the tem… |
| 1.3.6.1.4.1.20044.7.2.1.21.11 | Scalarmgnt2AlmChassisTempHiWarn | read-only | current | Chassis Temperature High Warning :This OID indicates that the chassis temperature rose above the warning threshold (+50C) <Help> This warning indicates that th… |
| 1.3.6.1.4.1.20044.7.2.1.21.12 | Scalarmgnt2AlmChassisTempLoWarn | read-only | current | Chassis Temperature Low Warning :This OID indicates that the chassis temperature dropped below the warning threshold (0C) <Help> This warning indicates that th… |
| 1.3.6.1.4.1.20044.7.2.1.24 | Nodemgnt2AlmfanPwrMgmnt | |||
| 1.3.6.1.4.1.20044.7.2.1.24.12 | Scalarmgnt2AlmFanPwrProtOn | read-only | current | Fan Backup Power :This OID indicates the backup power on the FAN module is switched on <Condtype> FAN_PWR_PROT_ON <Probcause> powerProblem (36) <Alarmtype> equ… |
| 1.3.6.1.4.1.20044.7.2.1.24.13 | Scalarmgnt2AlmFanPwrFail1 | read-only | current | Fan Main Power :This OID indicates a failure on the main power of the FAN module <Help> This alarm indicates if one of the tow main power convert of the Fan mo… |
| 1.3.6.1.4.1.20044.7.2.1.24.15 | Scalarmgnt2AlmFanDefFuseA | read-only | current | Fan Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Fan board <Help> Status of the Fan module Fuse A <Condtype> … |
| 1.3.6.1.4.1.20044.7.2.1.24.16 | Scalarmgnt2AlmFanDefFuseB | read-only | current | Fan Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Fan board <Help> Status of the Fan module Fuse B <Condtype> … |
| 1.3.6.1.4.1.20044.7.2.1.25 | Nodemgnt2AlmventFilterMgmnt | |||
| 1.3.6.1.4.1.20044.7.2.1.25.1 | Scalarmgnt2AlmVentFilterAbsent | read-only | current | Dust Filter Absent :This OID indicates that the dust filter is not present<Help> This alarm indicates if the Filter module is detected in the chassis. <Condtyp… |
| 1.3.6.1.4.1.20044.7.2.1.27 | Nodemgnt2AlmalmWdmInternal1 | |||
| 1.3.6.1.4.1.20044.7.2.1.27.2 | Scalarmgnt2AlmWdmSlot1Modif | read-only | current | Modification WDM Slot 1 :This OID indicates a modification on the WDM spectrum on the PM in Slot 1 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.3 | Scalarmgnt2AlmWdmSlot2Modif | read-only | current | Modification WDM Slot 2 :This OID indicates a modification on the WDM spectrum on the PM in Slot 2 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.4 | Scalarmgnt2AlmWdmSlot3Modif | read-only | current | Modification WDM Slot 3 :This OID indicates a modification on the WDM spectrum on the PM in Slot 3 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.5 | Scalarmgnt2AlmWdmSlot4Modif | read-only | current | Modification WDM Slot 4 :This OID indicates a modification on the WDM spectrum on the PM in Slot 4 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.6 | Scalarmgnt2AlmWdmSlot5Modif | read-only | current | Modification WDM Slot 5 :This OID indicates a modification on the WDM spectrum on the PM in Slot 5 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.7 | Scalarmgnt2AlmWdmSlot6Modif | read-only | current | Modification WDM Slot 6 :This OID indicates a modification on the WDM spectrum on the PM in Slot 6 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.8 | Scalarmgnt2AlmWdmSlot7Modif | read-only | current | Modification WDM Slot 7 :This OID indicates a modification on the WDM spectrum on the PM in Slot 7 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.9 | Scalarmgnt2AlmWdmSlot8Modif | read-only | current | Modification WDM Slot 8 :This OID indicates a modification on the WDM spectrum on the PM in Slot 8 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.10 | Scalarmgnt2AlmWdmSlot9Modif | read-only | current | Modification WDM Slot 9 :This OID indicates a modification on the WDM spectrum on the PM in Slot 9 of the Chassis . <Help> This status indicates indicates a mo… |
| 1.3.6.1.4.1.20044.7.2.1.27.11 | Scalarmgnt2AlmWdmSlot10Modif | read-only | current | Modification WDM Slot 10 :This OID indicates a modification on the WDM spectrum on the PM in Slot 10 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.27.12 | Scalarmgnt2AlmWdmSlot11Modif | read-only | current | Modification WDM Slot 11 :This OID indicates a modification on the WDM spectrum on the PM in Slot 11 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28 | Nodemgnt2AlmalmWdmInternal2 | |||
| 1.3.6.1.4.1.20044.7.2.1.28.1 | Scalarmgnt2AlmWdmSlot12Modif | read-only | current | Modification WDM Slot 12 :This OID indicates a modification on the WDM spectrum on the PM in Slot 12 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.2 | Scalarmgnt2AlmWdmSlot13Modif | read-only | current | Modification WDM Slot 13 :This OID indicates a modification on the WDM spectrum on the PM in Slot 13 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.3 | Scalarmgnt2AlmWdmSlot14Modif | read-only | current | Modification WDM Slot 14 :This OID indicates a modification on the WDM spectrum on the PM in Slot 14 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.4 | Scalarmgnt2AlmWdmSlot15Modif | read-only | current | Modification WDM Slot 15 :This OID indicates a modification on the WDM spectrum on the PM in Slot 15 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.5 | Scalarmgnt2AlmWdmSlot16Modif | read-only | current | Modification WDM Slot 16 :This OID indicates a modification on the WDM spectrum on the PM in Slot 16 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.6 | Scalarmgnt2AlmWdmSlot17Modif | read-only | current | Modification WDM Slot 17 :This OID indicates a modification on the WDM spectrum on the PM in Slot 17 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.7 | Scalarmgnt2AlmWdmSlot18Modif | read-only | current | Modification WDM Slot 18 :This OID indicates a modification on the WDM spectrum on the PM in Slot 18 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.8 | Scalarmgnt2AlmWdmSlot19Modif | read-only | current | Modification WDM Slot 19 :This OID indicates a modification on the WDM spectrum on the PM in Slot 19 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.9 | Scalarmgnt2AlmWdmSlot20Modif | read-only | current | Modification WDM Slot 20 :This OID indicates a modification on the WDM spectrum on the PM in Slot 20 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.10 | Scalarmgnt2AlmWdmSlot21Modif | read-only | current | Modification WDM Slot 21 :This OID indicates a modification on the WDM spectrum on the PM in Slot 21 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.11 | Scalarmgnt2AlmWdmSlot22Modif | read-only | current | Modification WDM Slot 22 :This OID indicates a modification on the WDM spectrum on the PM in Slot 22 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.12 | Scalarmgnt2AlmWdmSlot23Modif | read-only | current | Modification WDM Slot 23 :This OID indicates a modification on the WDM spectrum on the PM in Slot 23 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.28.13 | Scalarmgnt2AlmWdmSlot24Modif | read-only | current | Modification WDM Slot 24 :This OID indicates a modification on the WDM spectrum on the PM in Slot 24 of the Chassis . <Help> This status indicates indicates a … |
| 1.3.6.1.4.1.20044.7.2.1.29 | Nodemgnt2AlmalmWdmInternal3 | |||
| 1.3.6.1.4.1.20044.7.2.1.29.2 | Scalarmgnt2AlmLldponlySlot1 | read-only | current | Subnet Bridging detected Slot 1 :This OID indicates an external subnet is detected on M-Plane on slot 1.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.3 | Scalarmgnt2AlmLldponlySlot2 | read-only | current | Subnet Bridging detected Slot 2 :This OID indicates an external subnet is detected on M-Plane on slot 2.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.4 | Scalarmgnt2AlmLldponlySlot3 | read-only | current | Subnet Bridging detected Slot 3 :This OID indicates an external subnet is detected on M-Plane on slot 3.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.5 | Scalarmgnt2AlmLldponlySlot4 | read-only | current | Subnet Bridging detected Slot 4 :This OID indicates an external subnet is detected on M-Plane on slot 4.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.6 | Scalarmgnt2AlmLldponlySlot5 | read-only | current | Subnet Bridging detected Slot 5 :This OID indicates an external subnet is detected on M-Plane on slot 5.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.7 | Scalarmgnt2AlmLldponlySlot6 | read-only | current | Subnet Bridging detected Slot 6 :This OID indicates an external subnet is detected on M-Plane on slot 6.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.8 | Scalarmgnt2AlmLldponlySlot7 | read-only | current | Subnet Bridging detected Slot 7 :This OID indicates an external subnet is detected on M-Plane on slot 7.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.9 | Scalarmgnt2AlmLldponlySlot8 | read-only | current | Subnet Bridging detected Slot 8 :This OID indicates an external subnet is detected on M-Plane on slot 8.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.10 | Scalarmgnt2AlmLldponlySlot9 | read-only | current | Subnet Bridging detected Slot 9 :This OID indicates an external subnet is detected on M-Plane on slot 9.<Help> An external subnet is detected on M-plane. Check… |
| 1.3.6.1.4.1.20044.7.2.1.29.11 | Scalarmgnt2AlmLldponlySlot10 | read-only | current | Subnet Bridging detected Slot 10 :This OID indicates an external subnet is detected on M-Plane on slot 10.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.29.12 | Scalarmgnt2AlmLldponlySlot11 | read-only | current | Subnet Bridging detected Slot 11 :This OID indicates an external subnet is detected on M-Plane on slot 11.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.29.13 | Scalarmgnt2AlmLldponlySlot12 | read-only | current | Subnet Bridging detected Slot 12 :This OID indicates an external subnet is detected on M-Plane on slot 12.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.29.14 | Scalarmgnt2AlmLldponlySlot13 | read-only | current | Subnet Bridging detected Slot 13 :This OID indicates an external subnet is detected on M-Plane on slot 13.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.29.15 | Scalarmgnt2AlmLldponlySlot14 | read-only | current | Subnet Bridging detected Slot 14 :This OID indicates an external subnet is detected on M-Plane on slot 14.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.29.16 | Scalarmgnt2AlmLldponlySlot15 | read-only | current | Subnet Bridging detected Slot 15 :This OID indicates an external subnet is detected on M-Plane on slot 15.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.30 | Nodemgnt2AlmalmWdmInternal4 | |||
| 1.3.6.1.4.1.20044.7.2.1.30.1 | Scalarmgnt2AlmLldponlySlot16 | read-only | current | Subnet Bridging detected Slot 16 :This OID indicates an external subnet is detected on M-Plane on slot 16.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.30.2 | Scalarmgnt2AlmLldponlySlot17 | read-only | current | Subnet Bridging detected Slot 17 :This OID indicates an external subnet is detected on M-Plane on slot 17.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.30.3 | Scalarmgnt2AlmLldponlySlot18 | read-only | current | Subnet Bridging detected Slot 18 :This OID indicates an external subnet is detected on M-Plane on slot 18.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.30.4 | Scalarmgnt2AlmLldponlySlot19 | read-only | current | Subnet Bridging detected Slot 19 :This OID indicates an external subnet is detected on M-Plane on slot 19.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.30.5 | Scalarmgnt2AlmLldponlySlot20 | read-only | current | Subnet Bridging detected Slot 20 :This OID indicates an external subnet is detected on M-Plane on slot 20.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.30.6 | Scalarmgnt2AlmLldponlySlot21 | read-only | current | Subnet Bridging detected Slot 21 :This OID indicates an external subnet is detected on M-Plane on slot 21.<Help> An external subnet is detected on M-plane. Che… |
| 1.3.6.1.4.1.20044.7.2.1.32 | Nodemgnt2AlmswAlarm1 | |||
| 1.3.6.1.4.1.20044.7.2.1.32.1 | Scalarmgnt2AlmApiError | read-only | current | Comm fail between Agent and Transport :This OID indicates a failure detected on the Agent.The failure is located on a communication process with the modules. <… |
| 1.3.6.1.4.1.20044.7.2.1.32.2 | Scalarmgnt2AlmFifoCmdError | read-only | current | SNMP Agent to Transport comm FIFO fail :This OID indicates a failure inside the FIFO stack. The FIFO containing the messages from the agent (write) to the PMs … |
| 1.3.6.1.4.1.20044.7.2.1.32.3 | Scalarmgnt2AlmPollingManagerError | read-only | current | Polling Manager fail :This OID indicates a failure on the Manager polling the PM's <Help> This alarm indicates if there is a polling manager failure between th… |
| 1.3.6.1.4.1.20044.7.2.1.32.4 | Scalarmgnt2AlmCpldCompatError | read-only | current | MGNT GATEWARE Update Error :This OID indicates a failure on the compatibility of the CPLD with the current chassis.<Help> This alarm indicates if there is a CP… |
| 1.3.6.1.4.1.20044.7.2.1.32.5 | Scalarmgnt2AlmCpldCompatWarning | read-only | current | MGNT GATEWARE Update Warning :This OID indicates a warning with the CPLD update to the latest version.<Help> This alarm indicates if there is a CPLD compatibil… |
| 1.3.6.1.4.1.20044.7.2.1.33 | Scalarmgnt2AlmapiErrorCode | read-only | current | API Error Identification :Error number and description of the abs1AlmApiError object <Condtype> API_ERROR_CODE_1 <Probcause> <Alarmtype> |
| 1.3.6.1.4.1.20044.7.2.1.34 | Nodemgnt2AlmlogMgmnt | |||
| 1.3.6.1.4.1.20044.7.2.1.34.1 | Scalarmgnt2AlmLogFileFull | read-only | current | Log File Full Alarm :This OID indicates that a log file is full. This file must be cleared to insure correct log function <Help> This alarm indicates that one … |
| 1.3.6.1.4.1.20044.7.2.1.34.2 | Scalarmgnt2AlmLog80Full | read-only | current | Log File Full Warning :This OID indicates that a log file is 80% full. <Help> This alarm indicates that one of the log file is 80% Full <Condtype> LOG_80_FULL … |
| 1.3.6.1.4.1.20044.7.2.1.34.3 | Scalarmgnt2AlmLogStorageAbsent | read-only | current | Log Storage Absent :This OID indicates the internal SD card dedicated to log storage is not detected, the log feature is currently disabled.<Help> This alarm i… |
| 1.3.6.1.4.1.20044.7.2.1.35 | Nodemgnt2AlmntpSyncLoss | |||
| 1.3.6.1.4.1.20044.7.2.1.35.1 | Scalarmgnt2AlmNtpSyncLoss | read-only | current | NTP Sync Loss :This OID indicates a loss of synchronisation with the NTP Server. <Help> This alarm indicates a loss of synchronisation with the NTP Server. <Co… |
| 1.3.6.1.4.1.20044.7.2.1.35.2 | Scalarmgnt2AlmCpuTempOverRange | read-only | current | CPU HighTemperature Warning :This OID indicates a temperature over the expected range on the CPU<Help> This warning indicates that the temperature of the CPU i… |
| 1.3.6.1.4.1.20044.7.2.1.36 | Nodemgnt2AlmcpldPsStatus | |||
| 1.3.6.1.4.1.20044.7.2.1.36.1 | Scalarmgnt2AlmCpldPs1Presence | read-only | current | Presence of Power Supply 1 :This OID indicates that Power Supply 1 is present<Help>This information bit indicates that the Power Supply module 1 is present in … |
| 1.3.6.1.4.1.20044.7.2.1.36.2 | Scalarmgnt2AlmCpldPs1Alert | read-only | current | Alert on Power Supply 1 :This OID indicates that a State or Alarm change has occurred on Power Supply 1.<Help> This alarm bit indicates that a State or Alarm c… |
| 1.3.6.1.4.1.20044.7.2.1.36.3 | Scalarmgnt2AlmCpldPs1InputPowerOk | read-only | current | Input Power OK on Power Supply 1 :This OID indicates whether the Input power applied to Power Supply 1 is valid.<Help> This alarm bit indicates whether the Inp… |
| 1.3.6.1.4.1.20044.7.2.1.36.4 | Scalarmgnt2AlmCpldPs1PowerGood | read-only | current | Power Good on Power Supply 1 :This OID indicates whether the Output voltage from Power Supply 1 is valid.<Help> This alarm bit indicates whether the Output vol… |
| 1.3.6.1.4.1.20044.7.2.1.36.5 | Scalarmgnt2AlmCpldPs2Presence | read-only | current | Presence of Power Supply 2 :This OID indicates that Power Supply 2 is present.<Help> This information bit indicates that the Power Supply module 2 is present i… |
| 1.3.6.1.4.1.20044.7.2.1.36.6 | Scalarmgnt2AlmCpldPs2Alert | read-only | current | Alert on Power Supply 2: This OID indicates that a State or Alarm change has occurred on Power Supply 2.<Help> This alarm bit indicates that a State or Alarm c… |
| 1.3.6.1.4.1.20044.7.2.1.36.7 | Scalarmgnt2AlmCpldPs2InputPowerOk | read-only | current | Input Power OK on Power Supply 2 :This OID indicates whether the Input power applied to Power Supply 2 is valid.<Help> This alarm bit indicates whether the Inp… |
| 1.3.6.1.4.1.20044.7.2.1.36.8 | Scalarmgnt2AlmCpldPs2PowerGood | read-only | current | Power Good on Power Supply 2 :This OID indicates whether the Output voltage from Power Supply 2 is valid.<Help> This alarm bit indicates whether the Output vol… |
| 1.3.6.1.4.1.20044.7.2.1.37 | Nodemgnt2Almps1StatusWord | |||
| 1.3.6.1.4.1.20044.7.2.1.37.2 | Scalarmgnt2AlmPs1SwCmlFault | read-only | deprecated | Communication, memory or logic fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with a Communication , memory or logic fault.<Help> … |
| 1.3.6.1.4.1.20044.7.2.1.37.3 | Scalarmgnt2AlmPs1SwTempFault | read-only | current | Temperature fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with a Temperature fault or warning.<Help> This OID indicates that Powe… |
| 1.3.6.1.4.1.20044.7.2.1.37.4 | Scalarmgnt2AlmPs1SwVinUvFault | read-only | current | Input under voltage fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an excess voltage fault on its input.<Help> This OID indic… |
| 1.3.6.1.4.1.20044.7.2.1.37.5 | Scalarmgnt2AlmPs1SwIoutOcFault | read-only | current | Output over current fault on Power Supply 1 :This OID indicates that Power Supply 1 is affected with an excess current on its output.<Help> This OID indicates … |
| 1.3.6.1.4.1.20044.7.2.1.37.6 | Scalarmgnt2AlmPs1SwVoutOvFault | read-only | current | Output over voltage fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an excess voltage on its output.<Help> This OID indicates … |
| 1.3.6.1.4.1.20044.7.2.1.37.7 | Scalarmgnt2AlmPs1SwPsOff | read-only | current | PS Off on Power Supply 1 :This OID indicates that Power Supply 1 is off.<Help> This OID indicates that Power Supply 1 is off. <Condtype> PS1_SW_PS_OFF <Probcau… |
| 1.3.6.1.4.1.20044.7.2.1.37.11 | Scalarmgnt2AlmPs1SwFans | read-only | current | Fans alarm on Power Supply 1: This OID indicates that a fan airflow fault or warning occurred on Power Supply 1.<Help> This OID indicates that a fan airflow fa… |
| 1.3.6.1.4.1.20044.7.2.1.37.12 | Scalarmgnt2AlmPs1SwPwGoodNok | read-only | current | Power Good alarm on Power Supply 1: This OID indicates that the POWER_GOOD status was negated on Power Supply 1.<Help> This OID indicates that the POWER_GOOD s… |
| 1.3.6.1.4.1.20044.7.2.1.37.14 | Scalarmgnt2AlmPs1SwInput | read-only | current | Input alarm on Power Supply 1: This OID indicates that an input voltage, current or power fault or warning has occurred on Power Supply 1.<Help> This OID indic… |
| 1.3.6.1.4.1.20044.7.2.1.37.15 | Scalarmgnt2AlmPs1SwIout | read-only | current | Output current alarm on Power Supply 1: This OID indicates that an output current or power fault or warning has occurred on Power Supply 1.<Help> This OID indi… |
| 1.3.6.1.4.1.20044.7.2.1.37.16 | Scalarmgnt2AlmPs1SwVout | read-only | current | Output voltage alarm on Power Supply 1: This OID indicates that an output voltage fault or warning has occurred on Power Supply 1.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.38 | Nodemgnt2Almps1StatusVoutIout | |||
| 1.3.6.1.4.1.20044.7.2.1.38.1 | Scalarmgnt2AlmPs1PoutOpWarning | read-only | current | Output Overpower Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Overpower Warning.<Help> This OID indicates that … |
| 1.3.6.1.4.1.20044.7.2.1.38.2 | Scalarmgnt2AlmPs1PoutOpFault | read-only | current | Output Overpower Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Overpower Fault.<Help> This OID indicates that Powe… |
| 1.3.6.1.4.1.20044.7.2.1.38.6 | Scalarmgnt2AlmPs1IoutOcWarning | read-only | current | Output Over Current Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Over Current Warning.<Help> This OID indicates… |
| 1.3.6.1.4.1.20044.7.2.1.38.8 | Scalarmgnt2AlmPs1IoutOcFault | read-only | current | Output Over Current Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Over Current Fault.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.38.13 | Scalarmgnt2AlmPs1VoutUvFault | read-only | current | Output Under Voltage Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Under Voltage Fault.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.38.16 | Scalarmgnt2AlmPs1VoutOvFault | read-only | current | Output voltage alarm on Power Supply 2: This OID indicates that Power Supply 1 is affected with an Output Over Voltage Fault.<Help> This OID indicates that Pow… |
| 1.3.6.1.4.1.20044.7.2.1.39 | Nodemgnt2Almps1StatusInputTemp | |||
| 1.3.6.1.4.1.20044.7.2.1.39.7 | Scalarmgnt2AlmPs1OtWarning | read-only | current | Over Temperature Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Over Voltage Fault.<Help> This OID indicates that… |
| 1.3.6.1.4.1.20044.7.2.1.39.8 | Scalarmgnt2AlmPs1OtFault | read-only | current | Over Temperature Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Over Temperature Fault.<Help> This OID indicates that Powe… |
| 1.3.6.1.4.1.20044.7.2.1.39.9 | Scalarmgnt2AlmPs1PinOpWarning | read-only | current | PIn Over Power Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with a PIn Over Power Warning.<Help> This OID indicates that Power… |
| 1.3.6.1.4.1.20044.7.2.1.39.10 | Scalarmgnt2AlmPs1IinOcWarning | read-only | current | Input Over Current Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Input Over Current Warning.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.39.11 | Scalarmgnt2AlmPs1IinOcFault | read-only | current | Output Over Current Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Output Over Current Fault.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.39.12 | Scalarmgnt2AlmPs1VinUvOff | read-only | current | Unit Off for Insufficient Voltage on Power Supply 1: This OID indicates that Power Supply 1 is off due to insufficient input voltage.<Help> This OID indicates … |
| 1.3.6.1.4.1.20044.7.2.1.39.13 | Scalarmgnt2AlmPs1VinUvFault | read-only | current | Input Under Voltage Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Input Under Voltage Fault.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.39.14 | Scalarmgnt2AlmPs1VinUvWarning | read-only | current | Input Under Voltage Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Input Under Voltage Warning.<Help> This OID indicates… |
| 1.3.6.1.4.1.20044.7.2.1.39.15 | Scalarmgnt2AlmPs1VinOvWarning | read-only | current | Input Over Voltage Warning on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Input Over Voltage Warning.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.39.16 | Scalarmgnt2AlmPs1VinOvFault | read-only | current | Input Over Voltage Fault on Power Supply 1: This OID indicates that Power Supply 1 is affected with an Input Over Voltage Fault.<Help> This OID indicates that … |
| 1.3.6.1.4.1.20044.7.2.1.40 | Nodemgnt2Almps1StatusCmlFan | |||
| 1.3.6.1.4.1.20044.7.2.1.40.4 | Scalarmgnt2AlmPs1Fan1SpeedOverridden | read-only | current | Fan1 Speed Overridden on Power Supply 1 :This OID indicates that the default fan speed was overridden by the user on Power Supply 1.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.40.6 | Scalarmgnt2AlmPs1FanWarning | read-only | current | Fan Warning on Power Supply 1 :This OID indicates that Power Supply 1 has a Fan Warning.<Help> This OID indicates that Power Supply 1 has a Fan Warning. <Condt… |
| 1.3.6.1.4.1.20044.7.2.1.40.8 | Scalarmgnt2AlmPs1FanFault | read-only | current | Fan Fault on Power Supply 1 :This OID indicates that Power Supply 1 has a Fan Fault.<Help> This OID indicates that Power Supply 1 has a Fan Fault. <Condtype> P… |
| 1.3.6.1.4.1.20044.7.2.1.40.14 | Scalarmgnt2AlmPs1PacketErrCheckFail | read-only | current | Packet error Check Failed on Power Supply 1 :This OID indicates that a corrupt PMBus packet was received on Power Supply 1.<Help> This OID indicates that a cor… |
| 1.3.6.1.4.1.20044.7.2.1.40.15 | Scalarmgnt2AlmPs1InvData | read-only | current | Invalid Data received on Power Supply 1 :This OID indicates that Power Supply 1 has received an Invalid Data word.<Help> This OID indicates that Power Supply 1… |
| 1.3.6.1.4.1.20044.7.2.1.40.16 | Scalarmgnt2AlmPs1InvCmd | read-only | current | Invalid Command received on Power Supply 1 :This OID indicates that Power Supply 1 has received an Invalid Command. <Help> This OID indicates that Power Supply… |
| 1.3.6.1.4.1.20044.7.2.1.41 | Nodemgnt2Almps2StatusWord | |||
| 1.3.6.1.4.1.20044.7.2.1.41.2 | Scalarmgnt2AlmPs2SwCmlFault | read-only | deprecated | Communication, memory or logic fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with a Communication , memory or logic fault.<Help> … |
| 1.3.6.1.4.1.20044.7.2.1.41.3 | Scalarmgnt2AlmPs2SwTempFault | read-only | current | Temperature fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with a Temperature fault or warning.<Help> This OID indicates that Powe… |
| 1.3.6.1.4.1.20044.7.2.1.41.4 | Scalarmgnt2AlmPs2SwVinUvFault | read-only | current | Input under voltage fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an excess voltage fault on its input.<Help> This OID indic… |
| 1.3.6.1.4.1.20044.7.2.1.41.5 | Scalarmgnt2AlmPs2SwIoutOcFault | read-only | current | Output over current fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an excess current on its output.<Help> This OID indicates … |
| 1.3.6.1.4.1.20044.7.2.1.41.6 | Scalarmgnt2AlmPs2SwVoutOvFault | read-only | current | Output over voltage fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an excess voltage on its output.<Help> This OID indicates … |
| 1.3.6.1.4.1.20044.7.2.1.41.7 | Scalarmgnt2AlmPs2SwPsOff | read-only | current | PS Off on Power Supply 2 :This OID indicates that Power Supply 2 is off.<Help> This OID indicates that Power Supply 2 is off. <Condtype> PS2_SW_PS_OFF <Probcau… |
| 1.3.6.1.4.1.20044.7.2.1.41.11 | Scalarmgnt2AlmPs2SwFans | read-only | current | Fans alarm on Power Supply 2 :This OID indicates that a fan airflow fault or warning occurred on Power Supply 2.<Help> This OID indicates that a fan airflow fa… |
| 1.3.6.1.4.1.20044.7.2.1.41.12 | Scalarmgnt2AlmPs2SwPwGoodNok | read-only | current | Power Good alarm on Power Supply 2 :This OID indicates that the POWER_GOOD status was negated on Power Supply 2.<Help> This OID indicates that the POWER_GOOD s… |
| 1.3.6.1.4.1.20044.7.2.1.41.14 | Scalarmgnt2AlmPs2SwInput | read-only | current | Input alarm on Power Supply 2 :This OID indicates that an input voltage, current or power fault or warning has occurred on Power Supply 2.<Help> This OID indic… |
| 1.3.6.1.4.1.20044.7.2.1.41.15 | Scalarmgnt2AlmPs2SwIout | read-only | current | Output current alarm on Power Supply 2 :This OID indicates that an output current or power fault or warning has occurred on Power Supply 2.<Help> This OID indi… |
| 1.3.6.1.4.1.20044.7.2.1.41.16 | Scalarmgnt2AlmPs2SwVout | read-only | current | Output voltage alarm on Power Supply 2 :This OID indicates that an output voltage fault or warning has occurred on Power Supply 2.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.42 | Nodemgnt2Almps2StatusVoutIout | |||
| 1.3.6.1.4.1.20044.7.2.1.42.1 | Scalarmgnt2AlmPs2PoutOpWarning | read-only | current | Output Overpower Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Overpower Warning.<Help> This OID indicates that … |
| 1.3.6.1.4.1.20044.7.2.1.42.2 | Scalarmgnt2AlmPs2PoutOpFault | read-only | current | Output Overpower Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Overpower Fault.<Help> This OID indicates that Powe… |
| 1.3.6.1.4.1.20044.7.2.1.42.6 | Scalarmgnt2AlmPs2IoutOcWarning | read-only | current | Output Over Current Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Over Current Warning.<Help> This OID indicates… |
| 1.3.6.1.4.1.20044.7.2.1.42.8 | Scalarmgnt2AlmPs2IoutOcFault | read-only | current | Output Over Current Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Over Current Fault.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.42.13 | Scalarmgnt2AlmPs2VoutUvFault | read-only | current | Output Under Voltage Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Under Voltage Fault.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.42.16 | Scalarmgnt2AlmPs2VoutOvFault | read-only | current | Output voltage alarm on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Over Voltage Fault.<Help> This OID indicates that Pow… |
| 1.3.6.1.4.1.20044.7.2.1.43 | Nodemgnt2Almps2StatusInputTemp | |||
| 1.3.6.1.4.1.20044.7.2.1.43.7 | Scalarmgnt2AlmPs2OtWarning | read-only | current | Over Temperature Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Over Voltage Fault.<Help> This OID indicates that… |
| 1.3.6.1.4.1.20044.7.2.1.43.8 | Scalarmgnt2AlmPs2OtFault | read-only | current | Over Temperature Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Over Temperature Fault.<Help> This OID indicates that Powe… |
| 1.3.6.1.4.1.20044.7.2.1.43.9 | Scalarmgnt2AlmPs2PinOpWarning | read-only | current | PIn Over Power Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with a PIn Over Power Warning.<Help> This OID indicates that Power… |
| 1.3.6.1.4.1.20044.7.2.1.43.10 | Scalarmgnt2AlmPs2IinOcWarning | read-only | current | Input Over Current Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Input Over Current Warning.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.43.11 | Scalarmgnt2AlmPs2IinOcFault | read-only | current | Output Over Current Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Output Over Current Fault.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.43.12 | Scalarmgnt2AlmPs2VinUvOff | read-only | current | Unit Off for Insufficient Voltage on Power Supply 2 :This OID indicates that Power Supply 2 is off due to insufficient input voltage.<Help> This OID indicates … |
| 1.3.6.1.4.1.20044.7.2.1.43.13 | Scalarmgnt2AlmPs2VinUvFault | read-only | current | Input Under Voltage Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Input Under Voltage Fault.<Help> This OID indicates tha… |
| 1.3.6.1.4.1.20044.7.2.1.43.14 | Scalarmgnt2AlmPs2VinUvWarning | read-only | current | Input Under Voltage Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Input Under Voltage Warning.<Help> This OID indicates… |
| 1.3.6.1.4.1.20044.7.2.1.43.15 | Scalarmgnt2AlmPs2VinOvWarning | read-only | current | Input Over Voltage Warning on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Input Over Voltage Warning.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.43.16 | Scalarmgnt2AlmPs2VinOvFault | read-only | current | Input Over Voltage Fault on Power Supply 2 :This OID indicates that Power Supply 2 is affected with an Input Over Voltage Fault.<Help> This OID indicates that … |
| 1.3.6.1.4.1.20044.7.2.1.44 | Nodemgnt2Almps2StatusCmlFan | |||
| 1.3.6.1.4.1.20044.7.2.1.44.4 | Scalarmgnt2AlmPs2Fan1SpeedOverridden | read-only | current | Fan1 Speed Overridden on Power Supply 2 :This OID indicates that the default fan speed was overridden by the user on Power Supply 2.<Help> This OID indicates t… |
| 1.3.6.1.4.1.20044.7.2.1.44.6 | Scalarmgnt2AlmPs2FanWarning | read-only | current | Fan Warning on Power Supply 2 :This OID indicates that Power Supply 2 has a Fan Warning.<Help> This OID indicates that Power Supply 2 has a Fan Warning. <Condt… |
| 1.3.6.1.4.1.20044.7.2.1.44.8 | Scalarmgnt2AlmPs2FanFault | read-only | current | Fan Fault on Power Supply 2 :This OID indicates that Power Supply 2 has a Fan Fault.<Help> This OID indicates that Power Supply 2 has a Fan Fault. <Condtype> P… |
| 1.3.6.1.4.1.20044.7.2.1.44.14 | Scalarmgnt2AlmPs2PacketErrCheckFail | read-only | current | Packet error Check Failed on Power Supply 2 :This OID indicates that a corrupt PMBus packet was received on Power Supply 2.<Help> This OID indicates that a cor… |
| 1.3.6.1.4.1.20044.7.2.1.44.15 | Scalarmgnt2AlmPs2InvData | read-only | current | Invalid Data received on Power Supply 2 :This OID indicates that Power Supply 2 has received an Invalid Data word.<Help> This OID indicates that Power Supply 2… |
| 1.3.6.1.4.1.20044.7.2.1.44.16 | Scalarmgnt2AlmPs2InvCmd | read-only | current | Invalid Command received on Power Supply 2 :This OID indicates that Power Supply 2 has received an Invalid Command. <Help> This OID indicates that Power Supply… |
| 1.3.6.1.4.1.20044.7.2.2 | Nodemgnt2controls | |||
| 1.3.6.1.4.1.20044.7.2.2.5 | Nodemgnt2Ctrlsynth5 | |||
| 1.3.6.1.4.1.20044.7.2.2.5.2 | Scalarmgnt2CtrlChassisShutdown | read-write | current | Shut Down of the Management Module :This OID shall be set before shutting down the Chassis power. A delay of 5 sec is necessary between this OID is set and pow… |
| 1.3.6.1.4.1.20044.7.2.2.5.3 | Scalarmgnt2CtrlChassisWarmReset | read-write | current | Reset of the Management Module :This oid triggers a 'warm' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration rem… |
| 1.3.6.1.4.1.20044.7.2.2.5.4 | Scalarmgnt2CtrlChassisColdReset | read-write | current | Cold Reset of the Management Module :This oid triggers a 'cold' reset of the Chassis . This type of reset is not traffic affecting and the modules configuratio… |
| 1.3.6.1.4.1.20044.7.2.2.18 | Nodemgnt2CtrltestLed | |||
| 1.3.6.1.4.1.20044.7.2.2.18.1 | Scalarmgnt2CtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the chassis to gre… |
| 1.3.6.1.4.1.20044.7.2.2.18.2 | Scalarmgnt2CtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the chassis to red |
| 1.3.6.1.4.1.20044.7.2.2.18.3 | Scalarmgnt2CtrlLedOff | read-write | current | Switch off Leds Test :This OID switches off all the Leds as a test feature <Help> This control initiates a test leds turning all the LEDs of the complete chass… |
| 1.3.6.1.4.1.20044.7.2.2.19 | Nodemgnt2CtrllogFile | |||
| 1.3.6.1.4.1.20044.7.2.2.19.1 | Scalarmgnt2CtrlLogFileReset | read-write | current | Log File Reset :This OID clears all the log files |
| 1.3.6.1.4.1.20044.7.2.2.23 | Nodemgnt2CtrlmgntSaveConfig | |||
| 1.3.6.1.4.1.20044.7.2.2.23.1 | Scalarmgnt2CtrlSaveConfig | read-write | current | Save Configuration :This OID is used save the configuration related to the enable and mode traps objects <Help> This control saves the customer configuration o… |
| 1.3.6.1.4.1.20044.7.2.2.24 | Nodemgnt2CtrlmgntGetGlobalConfig | |||
| 1.3.6.1.4.1.20044.7.2.2.24.1 | Scalarmgnt2CtrlGetGlobalConfig | read-write | current | Get Global Chassis Config :This OID is used to create a global configuration file of the chassis <Help> This control creates a single configuration file from P… |
| 1.3.6.1.4.1.20044.7.2.2.25 | Nodemgnt2CtrlmgntPutGlobalConfig | |||
| 1.3.6.1.4.1.20044.7.2.2.25.1 | Scalarmgnt2CtrlPutGlobalConfig | read-write | current | Put Global Chassis Config :This OID is used to extract a global configuration file of the chassis <Help> This control creates configuration files to PM's and M… |
| 1.3.6.1.4.1.20044.7.2.2.26 | Nodemgnt2CtrlmgntAcknowledge | |||
| 1.3.6.1.4.1.20044.7.2.2.26.1 | Scalarmgnt2CtrlAcknowledge | read-write | current | Alarm Ack. :This OID is used to acknowledge the current active alarms of the chassis <Help> This control is used to acknowledge the current active alarms of th… |
| 1.3.6.1.4.1.20044.7.2.3 | Nodemgnt2config | |||
| 1.3.6.1.4.1.20044.7.2.3.17 | Nodemgnt2CfgethPort2 | |||
| 1.3.6.1.4.1.20044.7.2.3.17.1 | Scalarmgnt2CfgEthPort2Disable | read-write | current | 2nd Ethernet Port Disable :This OID disables 'Ethernet Port 2' .When not required, this port must be disabled in order to prevent unwanted access. <Help> Disab… |
| 1.3.6.1.4.1.20044.7.2.3.17.2 | Scalarmgnt2CfgChassisEthernetSplit | read-write | current | Chassis Ethernet Split :This OID enables the split between the two kendings. <Help> Enable/Disable the switch between the two kendings |
| 1.3.6.1.4.1.20044.7.2.3.18 | Scalarmgnt2CfgmgntDccEnable | read-write | current | DCC Access :This OID selects the mode to enable the DCC on the slots. This Mode enables the Slots 2-4-6-8-10 , or the Slots 2-6-10-14-18. <Help> Defines the DC… |
| 1.3.6.1.4.1.20044.7.2.3.20 | Nodemgnt2CfgpmTrapEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.20.1 | Scalarmgnt2CfgPmCriticalTrapEn | read-write | current | Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for all the PM plugged in the chassis <Help> In detailed tra… |
| 1.3.6.1.4.1.20044.7.2.3.20.2 | Scalarmgnt2CfgPmMajorTrapEn | read-write | current | Major Alarm Traps Enable :This OID, when set, enables the generation of the major alarm trap for all the PM plugged in the chassis <Help> In detailed traps mec… |
| 1.3.6.1.4.1.20044.7.2.3.20.3 | Scalarmgnt2CfgPmMinorTrapEn | read-write | current | Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for all the PM plugged in the chassis <Help> In detailed traps mec… |
| 1.3.6.1.4.1.20044.7.2.3.20.5 | Scalarmgnt2CfgPmControlTrapEn | read-write | current | Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a PM plugged in the chassis <Help> In detailed traps mecha… |
| 1.3.6.1.4.1.20044.7.2.3.20.6 | Scalarmgnt2CfgPmConfigTrapEn | read-write | current | Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a PM plugged in the chassis is modified <Help> In detailed … |
| 1.3.6.1.4.1.20044.7.2.3.21 | Nodemgnt2CfgmgntTrapEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.21.1 | Scalarmgnt2CfgMgntCriticalTrapEn | read-write | current | Management Critical Traps Enable :This OID, when set, enables the generation of the critical alarm trap for the Management and Fan modules board <Help> In deta… |
| 1.3.6.1.4.1.20044.7.2.3.21.2 | Scalarmgnt2CfgMgntMajorTrapEn | read-write | current | Management Major Traps Enable :This OID, when set, enables the generation of the major alarm trap for the Management and Fan modules board <Help> In detailed t… |
| 1.3.6.1.4.1.20044.7.2.3.21.3 | Scalarmgnt2CfgMgntMinorTrapEn | read-write | current | Management Minor Traps Enable :This OID, when set, enables the generation of the minor alarm trap for the Management and Fan modules board <Help> In detailed t… |
| 1.3.6.1.4.1.20044.7.2.3.21.5 | Scalarmgnt2CfgMgntControlTrapEn | read-write | current | Management Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a Management plugged in the chassis <Help> In d… |
| 1.3.6.1.4.1.20044.7.2.3.21.6 | Scalarmgnt2CfgMgntConfigTrapEn | read-write | current | Management Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a Management plugged in the chassis is modified … |
| 1.3.6.1.4.1.20044.7.2.3.21.7 | Scalarmgnt2CfgMgntEventTrapEn | read-write | current | Management Event Traps Enable :This OID, when set, enables the generation of a trap when an event occurs on the chassis <Help> In detailed traps mechanism, ena… |
| 1.3.6.1.4.1.20044.7.2.3.22 | Scalarmgnt2CfgmgntTrapMode | read-write | current | Traps Mode :This OID is used to define the trap mode (synthetic or detailed mode) <Help> Selects the traps mechanism |
| 1.3.6.1.4.1.20044.7.2.3.23 | Nodemgnt2CfgsyslogEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.23.1 | Scalarmgnt2CfgSyslogEventEn | read-write | current | Syslog Event Enable :This OID, when set, enables the generation of a syslog, when an event has been detected <Help> Enable a syslog emission on event detected … |
| 1.3.6.1.4.1.20044.7.2.3.23.2 | Scalarmgnt2CfgSyslogConfigEn | read-write | current | Syslog Config Enable :This OID, when set, enables the generation of a syslog, when the configuration has been changed. <Help> Enable a syslog emission on a con… |
| 1.3.6.1.4.1.20044.7.2.3.23.3 | Scalarmgnt2CfgSyslogCtrlEn | read-write | current | Syslog Control Enable :This OID, when set, enables the generation of a syslog, when a control is set <Help> Enable a syslog emission on a control operated on t… |
| 1.3.6.1.4.1.20044.7.2.3.23.4 | Scalarmgnt2CfgSyslogAlarmEn | read-write | current | Syslog Alarm Enable :This OID, when set, enables the generation of a syslog, when an alarm occurs <Help> Enable a syslog emission on an alarm detected on the c… |
| 1.3.6.1.4.1.20044.7.2.3.24 | Scalarmgnt2CfgntpTimeZone | read-write | current | NTP Time Zone :This OID defines the time zone of the MGNT board for the NTP server <Help> This object defines the time zone of the MGNT board (from -12 to +12 … |
| 1.3.6.1.4.1.20044.7.2.3.25 | Nodemgnt2CfgpmConfEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.25.1 | Scalarmgnt2CfgPmBackupEnable | read-write | current | Automatic Config Backup :This OID enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modification. <Help> This paramet… |
| 1.3.6.1.4.1.20044.7.2.3.25.2 | Scalarmgnt2CfgPmRestoreEnable | read-write | current | Automatic Config Restore :This OID enables the automatic PM configuration restore mechanism on PM insertion <Help> This parameter enables the automatic PM conf… |
| 1.3.6.1.4.1.20044.7.2.3.26 | Scalarmgnt2CfginactivityTimeout | read-write | current | Idle Timeout :This OID defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI. <Help> This object defines the idle timeo… |
| 1.3.6.1.4.1.20044.7.2.3.28 | Scalarmgnt2CfgcraftAccess | read-write | current | CRAFT access :This OID selects the remote access to a CRAFT user. <Help> This object defines the access for a remote CRAFT. |
| 1.3.6.1.4.1.20044.7.2.3.29 | Scalarmgnt2CfgperfModes1 | read-write | current | PERF Synchro Source :This OID selects the source of the synchronisation (Internal/External). <Help> This object defines the source of the synchronization to op… |
| 1.3.6.1.4.1.20044.7.2.3.30 | Scalarmgnt2CfgalarmModelActiv | read-write | current | Acknowledge mode :This OID defines the alarms akcnowledge mode <Help> This configuration defines the alarms akcnowledge mode |
| 1.3.6.1.4.1.20044.7.2.3.31 | Scalarmgnt2CfgnetworkInput | read-write | current | Network input :This OID selects the connection of the Ethernet Network input to either the switches (2) or the daughter board (1) , in this case the MGNT can a… |
| 1.3.6.1.4.1.20044.7.2.3.32 | Scalarmgnt2CfgmasterEthMode | read-write | current | DHCP Master Ethernet Mode :This OID selects the mode of the Master Ethernet in DHCP mode (2) or in Static Mode(1) <Help> This configuration defines the use of … |
| 1.3.6.1.4.1.20044.7.2.3.33 | Scalarmgnt2CfgsubnetMode | read-write | current | DHCP Subnet Mode :This OID selects the mode of the Subnet in DHCP mode (2) or in Static Mode(1) <Help> This configuration defines the use of the Subnet Mode |
| 1.3.6.1.4.1.20044.7.2.3.34 | Nodemgnt2CfgrstpMode | |||
| 1.3.6.1.4.1.20044.7.2.3.34.1 | Scalarmgnt2CfgRstpEnable | read-write | current | RSTP Enable :This OID enables the RSTP algorythm <Help> This configuration defines the use of RSTP |
| 1.3.6.1.4.1.20044.7.2.3.35 | Nodemgnt2CfglldpMode | |||
| 1.3.6.1.4.1.20044.7.2.3.35.1 | Scalarmgnt2CfgLldpEnable | read-write | current | LLDP Enable :This OID enables the LLDP algorythm <Help> This configuration defines the use of LLDP |
| 1.3.6.1.4.1.20044.7.2.3.36 | Scalarmgnt2CfglogMode | read-write | current | Log Mode :This OID enables the log file mode<Help> This configuration defines the use of the log mod |
| 1.3.6.1.4.1.20044.7.2.3.37 | Nodemgnt2CfgnodeMode | |||
| 1.3.6.1.4.1.20044.7.2.3.37.1 | Scalarmgnt2CfgNodeControllerEnable | read-write | current | Node Controller Mode :This OID enables the node controller mode<Help> This configuration defines the use of the node controller mod |
| 1.3.6.1.4.1.20044.7.2.3.37.2 | Scalarmgnt2CfgNodeControllerStandaloneEnable | read-write | current | Node Controller Standalone :This OID enables the standalone option of the node controller mode<Help> This option restricts the node controller mode to a single… |
| 1.3.6.1.4.1.20044.7.2.3.38 | Nodemgnt2CfgunprivilegedUsersMode | |||
| 1.3.6.1.4.1.20044.7.2.3.38.1 | Scalarmgnt2CfgRestrictUnprivilegeUsers | read-write | current | Restrict Unprivileged Users Rights :This OID enables the restriction of unprivileged user rights to modify their own password <Help> This parameter enables the… |
| 1.3.6.1.4.1.20044.7.2.3.39 | Scalarmgnt2CfgoscDccLinkUpThreshold | read-write | current | OSC/DCC Link Up Thresh. [10-30]s :This OID defines the confirmation threshold to consider an OSC/DCC link as up <Help> This parameter defines the confirmation … |
| 1.3.6.1.4.1.20044.7.2.3.40 | Scalarmgnt2CfgoscDccLinkDownThreshold | read-write | current | OSC/DCC Link Down Thresh. [2-3]s :This OID defines the confirmation threshold to consider an OSC/DCC link as down <Help> This parameter defines the confirmatio… |
| 1.3.6.1.4.1.20044.7.2.3.41 | Scalarmgnt2CfgaccountAutoLock | read-write | current | Account Auto-Lock [-1 / 1-10] err :This OID defines the number of error password to lock an account. This counter is reset on successful login or after an admi… |
| 1.3.6.1.4.1.20044.7.2.3.42 | Scalarmgnt2CfgfailCountReset | read-write | current | Fail Count Reset [-1 / 1-10] hrs :This OID defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful logi… |
| 1.3.6.1.4.1.20044.7.2.3.43 | Scalarmgnt2CfgchassisIndex | read-write | current | Chassis Index :This OID defines the index of the chassis in the node context. This index is used to sort the chassis inside the Node and therefore must be uniq… |
| 1.3.6.1.4.1.20044.7.2.3.46 | Scalarmgnt2Cfgrj45EthernetPort | read-write | current | RJ45 Ethernet Port Mode :This OID defines the 'RJ45 Ethernet Ports' Mode. Default Mode is Enabled. <Help> Defines the RJ45 Ethernet ports Mode (Enabled = 0, Di… |
| 1.3.6.1.4.1.20044.7.2.3.47 | Nodemgnt2CfgospfMode | |||
| 1.3.6.1.4.1.20044.7.2.3.47.1 | Scalarmgnt2CfgOspfModeEnable | read-write | current | OSPF Mode :This OID defines the OSPF Mode. Default Mode is Disabled. <Help> Defines theOSPF Mode (Disabled = 1, Enabled = 2). |
| 1.3.6.1.4.1.20044.7.2.3.48 | Scalarmgnt2CfgnetworkPortMode | read-write | current | Network Port Mode :This OID defines the Network Port Mode. Default Mode is Stacking. <Help> Defines the Network Port Mode (Stacking = 0, DCN = 1). |
| 1.3.6.1.4.1.20044.7.2.3.49 | Scalarmgnt2CfgospfAreaNumber | read-write | current | OSPF Area Number :This OID defines the number of the OSPF area in the network configured with OSPF. <Help> This object defines the number of the OSPF area in a… |
| 1.3.6.1.4.1.20044.7.2.3.50 | Scalarmgnt2CfgospfFrontrouterMethNumber | read-write | current | OSPF FrontRouter Meth Number :This OID defines the slot of the front routeur instance in the chassis. <Help> This object defines the slot of the front routeur … |
| 1.3.6.1.4.1.20044.7.2.3.51 | Nodemgnt2CfgfrontrouterEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.51.1 | Scalarmgnt2CfgFrontrouterEnable | read-write | current | Front Router Mode :This OID activates the front router. Default Mode is Disabled. <Help> Activates the Front Router (Disabled = 1, Enabled = 2). |
| 1.3.6.1.4.1.20044.7.2.3.52 | Scalarmgnt2CfgospfFrontrouterMask | read-write | current | OSPF Front Router Mask :This OID defines the mask of the Front Router IP for the migration<Help> defines the mask of the Front Router IP for the migration |
| 1.3.6.1.4.1.20044.7.2.3.53 | Nodemgnt2CfgospfSnmp | |||
| 1.3.6.1.4.1.20044.7.2.3.53.1 | Scalarmgnt2CfgOspfSnmpEnable | read-write | current | OSPF SNMP :This OID defines the OSPF SNMP activation. Default Mode is Disabled. <Help> Defines the OSPF SNMP activation (Disabled = 1, Enabled = 2). |
| 1.3.6.1.4.1.20044.7.2.3.54 | Nodemgnt2CfgospfSecondIpEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.54.1 | Scalarmgnt2CfgOspfSecondIpEnable | read-write | current | OSPF Second IP Enable :This OID defined the OSFP Second IP functionality activation. Default Mode is Enabled. <Help> Defines the OSPF Second IP Address functio… |
| 1.3.6.1.4.1.20044.7.2.3.55 | Nodemgnt2CfgacPowerMonEnable | |||
| 1.3.6.1.4.1.20044.7.2.3.55.1 | Scalarmgnt2CfgAcPowerMonEnable | read-write | current | AC Power Monitoring Enable :This OID enables the monitoring of external AC power supplies (C700HC) <Help> This configuration enables or disables the monitoring… |
| 1.3.6.1.4.1.20044.7.2.4 | Nodemgnt2measures | |||
| 1.3.6.1.4.1.20044.7.2.4.16 | Scalarmgnt2Mesrchassistemperature | read-only | current | Chassis Temperature :This OID gives the Chassis temperature (Chassis Temperature = AV_S16/10) (Unit = C) <Help> This measure gives gives the Chassis temperatur… |
| 1.3.6.1.4.1.20044.7.2.4.17 | Scalarmgnt2MesrmContFanSpeed | read-only | current | Fan Speed on mCONT board :This OID gives the speed of the Fan in RPMs on the mCONT board. (Fan Speed = AV_S16) (Unit = RPM)<Help> This OID gives the speed of t… |
| 1.3.6.1.4.1.20044.7.2.4.18 | Scalarmgnt2MesrCpuCoreTemp | read-only | current | Hot spot temperature on CPU module :This OID gives the temperature of the hot spot in Celsius (PMBus Linear11 format) in the CPU core of the COM Express module… |
| 1.3.6.1.4.1.20044.7.2.4.19 | Scalarmgnt2MesrPs1ReadPIn | read-only | current | Input Power in Watts on Power Supply 1 :This OID gives the input power in Watts (PMBus Linear11 format) on Power Supply 1. (Input Power = LIN11(AV_S16)) (Unit … |
| 1.3.6.1.4.1.20044.7.2.4.20 | Scalarmgnt2MesrPs1ReadPOut | read-only | current | Output Power in Watts on Power Supply 1 :This OID gives the output Power in Watts (PMBus Linear11 format) on Power Supply 1. (Output Power = LIN11(AV_S16)) (Un… |
| 1.3.6.1.4.1.20044.7.2.4.21 | Scalarmgnt2MesrPs1Fan1Speed | read-only | current | Fan 1 Speed on Power Supply 1 :This OID gives the speed of Fan 1 in RPMs on Power Supply 1. (Fan Speed = AV_S16) (Unit = RPM)<Help> This measurement gives the … |
| 1.3.6.1.4.1.20044.7.2.4.22 | Scalarmgnt2MesrPs1Temp2 | read-only | current | Hot spot temperature on Power Supply 1 :This OID gives the temperature of the hot spot in Celsius (PMBus Linear11 format) on Power Supply 1. (Temperature = LIN… |
| 1.3.6.1.4.1.20044.7.2.4.23 | Scalarmgnt2MesrPs1Temp1 | read-only | current | Inlet temperature on Power Supply 1 :This OID gives the temperature of the inlet in Celsius (PMBus Linear11 format) on Power Supply 1. (Temperature = LIN11(AV_… |
| 1.3.6.1.4.1.20044.7.2.4.24 | Scalarmgnt2MesrPs1IOut | read-only | current | Output current on Power Supply 1 :This OID gives the measurement of the output current in Amperes (PMBus Linear11 format) on Power Supply 1. (Output current = … |
| 1.3.6.1.4.1.20044.7.2.4.25 | Scalarmgnt2MesrPs1VOut | read-only | current | Output voltage on Power Supply 1 :This OID gives the measurement of the output voltage in Volts (PMBus Linear11 format) on Power Supply 1. (Output voltage = AV… |
| 1.3.6.1.4.1.20044.7.2.4.26 | Scalarmgnt2MesrPs1IIn | read-only | current | Input current on Power Supply 1 :This OID gives the measurement of the input current in Amperes (PMBus Linear11 format) on Power Supply 1. (Input current = LIN… |
| 1.3.6.1.4.1.20044.7.2.4.27 | Scalarmgnt2MesrPs1vIn | read-only | current | Input voltage on Power Supply 1 :This OID gives the measurement of the input voltage in Volts (PMBus Linear11 format) on Power Supply 1. (Input voltage = LIN11… |
| 1.3.6.1.4.1.20044.7.2.4.28 | Scalarmgnt2MesrPs2ReadPIn | read-only | current | Input Power in Watts on Power Supply 2 :This OID gives the input Power in Watts (PMBus Linear11 format) on Power Supply 2. (Input power = LIN11(AV_S16)) (Unit … |
| 1.3.6.1.4.1.20044.7.2.4.29 | Scalarmgnt2MesrPs2ReadPOut | read-only | current | Output Power in Watts on Power Supply 2 :This OID gives the output Power in Watts (PMBus Linear11 format) on Power Supply 2. (Output power = LIN11(AV_S16)) (Un… |
| 1.3.6.1.4.1.20044.7.2.4.30 | Scalarmgnt2MesrPs2Fan1Speed | read-only | current | Fan 1 Speed on Power Supply 2 :This OID gives the speed of Fan 1 in RPMs on Power Supply 2. (Fan Speed = AV_S16) (Unit = RPM)<Help> This measurement gives the … |
| 1.3.6.1.4.1.20044.7.2.4.31 | Scalarmgnt2MesrPs2Temp2 | read-only | current | Hot spot temperature on Power Supply 2 :This OID gives the temperature of the hot spot in Celsius (PMBus Linear11 format) on Power Supply 2. (Temperature = LIN… |
| 1.3.6.1.4.1.20044.7.2.4.32 | Scalarmgnt2MesrPs2Temp1 | read-only | current | Inlet temperature on Power Supply 2 :This OID gives the temperature of the inlet in Celsius (PMBus Linear11 format) on Power Supply 2. (Temperature = LIN11(AV_… |
| 1.3.6.1.4.1.20044.7.2.4.33 | Scalarmgnt2MesrPs2IOut | read-only | current | Output current on Power Supply 2 :This OID gives the measurement of the output current in Amperes (PMBus Linear11 format) on Power Supply 2. (Output current = … |
| 1.3.6.1.4.1.20044.7.2.4.34 | Scalarmgnt2MesrPs2VOut | read-only | current | Output voltage on Power Supply 2 :This OID gives the measurement of the output voltage in Volts (PMBus Linear11 format) on Power Supply 2. (Output voltage = AV… |
| 1.3.6.1.4.1.20044.7.2.4.35 | Scalarmgnt2MesrPs2IIn | read-only | current | Input current on Power Supply 2 :This OID gives the measurement of the input current in Amperes (PMBus Linear11 format) on Power Supply 2. (Input current = LIN… |
| 1.3.6.1.4.1.20044.7.2.4.36 | Scalarmgnt2MesrPs2VIn | read-only | current | Input voltage on Power Supply 2 :This OID gives the measurement of the input voltage in Volts (PMBus Linear11 format) on Power Supply 2. (Input voltage = LIN11… |
| 1.3.6.1.4.1.20044.7.2.4.37 | Scalarmgnt2MesrPsGlobalOutputPower | read-only | current | Global output power of power supplies :This OID gives the measurement of the global ouput power in Watts (PMBus Linear11 format) delivered by the power supplie… |
| 1.3.6.1.4.1.20044.7.3 | Nodemgnt2Traps | |||
| 1.3.6.1.4.1.20044.7.3.1 | Notificationmgnt2TrapApi | current | Api error trap with its number | |
| 1.3.6.1.4.1.20044.7.3.2 | Notificationmgnt2TrapSwError | current | Chassis software error other API | |
| 1.3.6.1.4.1.20044.7.3.4 | Notificationmgnt2TrapBoardInserted | current | A board has been plugged in | |
| 1.3.6.1.4.1.20044.7.3.5 | Notificationmgnt2TrapBoardRemoved | current | A board has been plugged out | |
| 1.3.6.1.4.1.20044.7.3.6 | Notificationmgnt2TrapRestoreConfDone | current | The Configuration has been restored from the management board | |
| 1.3.6.1.4.1.20044.7.3.8 | Notificationmgnt2TrapGlobalPowerFail | current | A global power supply failure has been detected | |
| 1.3.6.1.4.1.20044.7.3.9 | Notificationmgnt2TrapFanPowerFail | current | A Fan power supply failure has been detected | |
| 1.3.6.1.4.1.20044.7.3.10 | Notificationmgnt2TrapGigmPowerFail | current | A power supply default has been detected in the management board | |
| 1.3.6.1.4.1.20044.7.3.11 | Notificationmgnt2TrapFanFail | current | A Fan failure has been detected | |
| 1.3.6.1.4.1.20044.7.3.20 | Notificationmgnt2TrapLogFileFull | current | Indicates that the corresponding log file is almost full | |
| 1.3.6.1.4.1.20044.7.3.30 | Notificationmgnt2TrapAlarm | current | Indicates that an alarm state has changed | |
| 1.3.6.1.4.1.20044.7.3.31 | Notificationmgnt2TrapEvent | current | Indicates that an event has occured | |
| 1.3.6.1.4.1.20044.7.3.32 | Notificationmgnt2TrapControl | current | Indicates that a control has been set to the module | |
| 1.3.6.1.4.1.20044.7.3.33 | Notificationmgnt2TrapConfig | current | Indicates that a config word has been changed | |
| 1.3.6.1.4.1.20044.7.3.50 | Scalarmgnt2TrapBoardNumber | read-only | current | This OID gives the slot number of the PM that sent the last trap |
| 1.3.6.1.4.1.20044.7.3.51 | Scalarmgnt2TrapSeverity | read-only | current | This OID gives the trap severity |
| 1.3.6.1.4.1.20044.7.3.52 | Scalarmgnt2TrapSourcePm | read-only | current | This OID gives the mnemonic of the pm who sent a trap |
| 1.3.6.1.4.1.20044.7.3.53 | Scalarmgnt2TrapSourcePortType | read-only | current | This OID gives the type of the port who sent a trap |
| 1.3.6.1.4.1.20044.7.3.54 | Scalarmgnt2TrapSourcePortNumber | read-only | current | This OID gives the port number of the PM that sent the last trap |
| 1.3.6.1.4.1.20044.7.3.55 | Scalarmgnt2TrapSourceLabel | read-only | current | This OID gives the label of the alarm who sent a trap |
| 1.3.6.1.4.1.20044.7.3.56 | Scalarmgnt2TrapSourceValue | read-only | current | This OID gives the value of the alarm who sent a trap |
| 1.3.6.1.4.1.20044.7.3.57 | Scalarmgnt2TrapEventLabel | read-only | current | This OID gives the label of the event |
| 1.3.6.1.4.1.20044.7.3.58 | Scalarmgnt2TrapNodeControllerIpAddress | read-only | current | This OID gives the IP address of the Node Controller |
| 1.3.6.1.4.1.20044.7.3.59 | Scalarmgnt2TrapChassisId | read-only | current | This OID gives the chassis ID |
| 1.3.6.1.4.1.20044.7.4 | Nodemgnt2SoftwareManagement | |||
| 1.3.6.1.4.1.20044.7.4.1 | Tablemgnt2DwlUploadingTable | not-accessible | deprecated | SNMP Agent SW packages in ram: List of the SNMP agent software packages available in /ram for download on the Chassis managment module flash |
| 1.3.6.1.4.1.20044.7.4.1.1 | Rowmgnt2DwlUploadingEntry | not-accessible | deprecated | Row definition for the package uploading table |
| 1.3.6.1.4.1.20044.7.4.1.1.1 | Columnmgnt2IndexUpload | read-only | deprecated | Index for uploading table |
| 1.3.6.1.4.1.20044.7.4.1.1.2 | Columnmgnt2DwlUploadFileName | read-only | deprecated | Package filename in RAM:This OID gives the name of the SNMP agent software packages in RAM |
| 1.3.6.1.4.1.20044.7.4.1.1.3 | Columnmgnt2ImmediateReplacement | read-write | deprecated | Immediat Agent Replacement:This OID indicates to switch to selected SNMP agent immediately or after reset of the MGNT2 |
| 1.3.6.1.4.1.20044.7.4.1.1.4 | Columnmgnt2FileUpload | read-write | deprecated | Agent File Upload:This OID validates the upload of the SNMP agent from RAM to FLASH |
| 1.3.6.1.4.1.20044.7.4.1.1.5 | Columnmgnt2DeletePackageFromRam | read-write | deprecated | Delete Package from RAM:This OID requests to delete the SNMP Agent SW package from RAM |
| 1.3.6.1.4.1.20044.7.4.1.1.6 | Columnmgnt2FlashingInProgress | read-only | deprecated | Flashing in Progress:This OID indicates whether there is a file upload to FLASH in progress |
| 1.3.6.1.4.1.20044.7.4.2 | Tablemgnt2DwlPackageTable | not-accessible | deprecated | List of SNMP agent software packages present in flash memory |
| 1.3.6.1.4.1.20044.7.4.2.1 | Rowmgnt2DwlPackageEntry | not-accessible | deprecated | Row definition for the package management table |
| 1.3.6.1.4.1.20044.7.4.2.1.1 | Columnmgnt2IndexPackage | read-only | deprecated | Index for package management table |
| 1.3.6.1.4.1.20044.7.4.2.1.2 | Columnmgnt2DwlPackageFileName | read-only | deprecated | Package File name in FLASH:This OID gives the name of the SNMP agent software package in FLASH |
| 1.3.6.1.4.1.20044.7.4.2.1.3 | Columnmgnt2ExtractedPack | read-only | deprecated | Extracted SNMP agent software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted |
| 1.3.6.1.4.1.20044.7.4.2.1.4 | Columnmgnt2SwitchTo | read-write | deprecated | Switch to package:This OID activates the SNMP Agent Software package |
| 1.3.6.1.4.1.20044.7.4.2.1.5 | Columnmgnt2Immediate | read-write | deprecated | Immediate SNMP agent activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next … |
| 1.3.6.1.4.1.20044.7.4.2.1.6 | Columnmgnt2DeletePackageFromFlash | read-write | deprecated | Delete package from FLASH:This OID deletes the SNMP agent software package from the FLASH |
| 1.3.6.1.4.1.20044.7.4.2.1.7 | Columnmgnt2PackageExtractionInProgress | read-only | deprecated | Package extraction in progress:This OID indicates that a SNMP agent software activation is in progress |
| 1.3.6.1.4.1.20044.7.4.3 | Scalarmgnt2DwlUploadingTableUpdate | read-write | deprecated | Uploading Table update:This OID updates the contents of the uploading table |
| 1.3.6.1.4.1.20044.7.4.4 | Tablemgnt2LoadPMTable | not-accessible | deprecated | List of the PM module software files (GW/SW) present on the repository |
| 1.3.6.1.4.1.20044.7.4.4.1 | Rowmgnt2LoadPMEntry | not-accessible | deprecated | Row definition for the LOAD article table |
| 1.3.6.1.4.1.20044.7.4.4.1.1 | Columnmgnt2LoadPMIndex | read-only | deprecated | Index for Load article table |
| 1.3.6.1.4.1.20044.7.4.4.1.2 | Columnmgnt2LoadFileName | read-only | deprecated | PM Upgrade filename:This OID gives the name of the file |
| 1.3.6.1.4.1.20044.7.4.4.1.3 | Columnmgnt2LoadFileType | read-only | deprecated | PM upgrade file type:This OID gives the type of file (gateware or software) |
| 1.3.6.1.4.1.20044.7.4.4.1.4 | Columnmgnt2LoadState | read-only | deprecated | PM upgrade status:This OID gives the status of the selected Load file |
| 1.3.6.1.4.1.20044.7.4.4.1.5 | Columnmgnt2LoadModuleNumber | read-write | deprecated | PM ugprade target:This OID defines the slot number of the PM to upgrade |
| 1.3.6.1.4.1.20044.7.4.4.1.6 | Columnmgnt2LoadResetMethod | read-write | deprecated | PM upgrade reset method:This OID defines the reset method (manual, immediate or scheduled) |
| 1.3.6.1.4.1.20044.7.4.4.1.7 | Columnmgnt2LoadResetMode | read-write | deprecated | PM upgrade reset mode:This OID defines the type of reset (cold or warm) |
| 1.3.6.1.4.1.20044.7.4.4.1.8 | Columnmgnt2LoadBankNumber | read-write | deprecated | PM upgrade bank number:This OID defines the target bank number in the PM's flash |
| 1.3.6.1.4.1.20044.7.4.4.1.9 | Columnmgnt2LoadDownloadProgress | read-only | deprecated | PM upgrade progress:This OID gives the upgrade progress (percentage) |
| 1.3.6.1.4.1.20044.7.4.4.1.10 | Columnmgnt2LoadTransfer | read-write | deprecated | PM upgrade transfer:This OID launchs the transfer of the associated file to the selected PM's flash |
| 1.3.6.1.4.1.20044.7.4.4.1.11 | Columnmgnt2LoadDelete | read-write | deprecated | PM upgrade delete file:This OID deletes the associated file from the RAM of the management board |
| 1.3.6.1.4.1.20044.7.4.5 | Scalarmgnt2LoadPMTableUpdate | read-write | deprecated | Load PM Table update:This OID updates the contents of the Load table |
| 1.3.6.1.4.1.20044.7.4.6 | Tablemgnt2DwlEkicraftPkgTable | not-accessible | deprecated | List of Ekicraft software packages present in flash memory |
| 1.3.6.1.4.1.20044.7.4.6.1 | Rowmgnt2DwlEkicraftPkgEntry | not-accessible | deprecated | Row definition for the package management table |
| 1.3.6.1.4.1.20044.7.4.6.1.1 | Columnmgnt2IndexEkicraftPkg | read-only | deprecated | Index for Ekicraft package management table |
| 1.3.6.1.4.1.20044.7.4.6.1.2 | Columnmgnt2DwlEkicraftPkgFileName | read-only | deprecated | Package File name in FLASH:This OID gives the name of the Ekicraft software package in FLASH |
| 1.3.6.1.4.1.20044.7.4.6.1.3 | Columnmgnt2DwlEkicraftExtractedPack | read-only | deprecated | Extracted Ekicraft software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted |
| 1.3.6.1.4.1.20044.7.4.6.1.4 | Columnmgnt2DwlEkicraftSwitchTo | read-write | deprecated | Switch to package:This OID activates the Ekicraft Software package |
| 1.3.6.1.4.1.20044.7.4.6.1.5 | Columnmgnt2DwlEkicraftImmediate | read-write | deprecated | Immediate Ekicraft activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next re… |
| 1.3.6.1.4.1.20044.7.4.6.1.6 | Columnmgnt2DeleteEkicraftPkgFromFlash | read-write | deprecated | Delete package from FLASH:This OID deletes the Ekicraft software package from the FLASH |
| 1.3.6.1.4.1.20044.7.4.6.1.7 | Columnmgnt2EkicraftPkgExtractionInProgress | read-only | deprecated | Package extraction in progress:This OID indicates that an Ekicraft activation is in progress |
| 1.3.6.1.4.1.20044.7.5 | Nodemgnt2ConfigManagement | |||
| 1.3.6.1.4.1.20044.7.5.1 | Tablemgnt2CnfUploadConfigFilesTable | not-accessible | deprecated | List of configuration files uploaded to RAM |
| 1.3.6.1.4.1.20044.7.5.1.1 | Rowmgnt2CnfUploadConfigFilesEntry | not-accessible | deprecated | Row definition for the package uploading table |
| 1.3.6.1.4.1.20044.7.5.1.1.1 | Columnmgnt2CnfUploadConfigIndex | read-only | deprecated | Index of config files |
| 1.3.6.1.4.1.20044.7.5.1.1.2 | Columnmgnt2CnfConfigFileName | read-only | deprecated | Configuration filename in RAM:This OID gives the name of the configuration file in RAM |
| 1.3.6.1.4.1.20044.7.5.1.1.3 | Columnmgnt2CnfConfigSlot | read-write | deprecated | Configuration target:This OID defines the target slot number for the configuration file |
| 1.3.6.1.4.1.20044.7.5.1.1.4 | Columnmgnt2CnfConfigUpload | read-write | deprecated | Configuration Upload:This OID uploads the configuration file to the specified slot number in the PM FLASH |
| 1.3.6.1.4.1.20044.7.5.1.1.5 | Columnmgnt2CnfDeleteConfigFile | read-write | deprecated | Configuration delete from RAM:This OID deletes the configuration file from RAM |
| 1.3.6.1.4.1.20044.7.5.2 | Tablemgnt2CnfManageConfigFilesTable | not-accessible | deprecated | List of configuration files uploaded to RAM |
| 1.3.6.1.4.1.20044.7.5.2.1 | Rowmgnt2CnfManageConfigFilesEntry | not-accessible | deprecated | Row definition for the package uploading table |
| 1.3.6.1.4.1.20044.7.5.2.1.1 | Columnmgnt2CnfManageConfigIndex | read-only | deprecated | Index of config file slots |
| 1.3.6.1.4.1.20044.7.5.2.1.2 | Columnmgnt2CnfManageConfigFileID | read-write | deprecated | Configuration file ID in FLASH:This OID gives the ID of the configuration file in MGNT2 FLASH |
| 1.3.6.1.4.1.20044.7.5.2.1.3 | Columnmgnt2CnfManageConfigFileName | read-write | deprecated | Configuration file name in FLASH:This OID gives the name of the configuration file in MGNT2 FLASH |
| 1.3.6.1.4.1.20044.7.5.2.1.4 | Columnmgnt2CnfModuleSlotNumber | read-write | deprecated | Configuration target:This OID defines the target module slot number for the configuration file |
| 1.3.6.1.4.1.20044.7.5.2.1.5 | Columnmgnt2CnfBackupConfig | read-write | deprecated | Configuration backup:This OID backups the configuration of the specified module to the selected file in MGNT2 FLASH |
| 1.3.6.1.4.1.20044.7.5.2.1.6 | Columnmgnt2CnfRestoreConfig | read-write | deprecated | Configuration Restore:This OID restores the configuration of the specified module from the selected file in MGNT2 FLASH |
| 1.3.6.1.4.1.20044.7.5.2.1.7 | Columnmgnt2CnfExportConfig | read-write | deprecated | Configuration Export:This OID exports the selected file in MGNT2 FLASH to a file in RAM |
| 1.3.6.1.4.1.20044.7.5.2.1.8 | Columnmgnt2CnfDeleteConfig | read-write | deprecated | Configuration delete from FLASH:This OID deletes the configuration file from the MGNT2 FLASH |
| 1.3.6.1.4.1.20044.7.6 | Nodemgnt2RemoteInventory | |||
| 1.3.6.1.4.1.20044.7.6.1 | Scalarmgnt2RinvHwPlatform | read-write | current | Chassis Hardware inventory:This OID gives the Hardware inventory of the Mgnt2 management module |
| 1.3.6.1.4.1.20044.7.6.2 | Scalarmgnt2RinvSoftwarePackage | read-write | current | Chassis Software package inventory:this OID gives the Software package inventory of the Mgnt2 management module |
| 1.3.6.1.4.1.20044.7.6.3 | Scalarmgnt2RinvGateware | read-write | current | Chassis Gateware inventory:This OID gives the gateware inventory of the Mgnt2 management module |
| 1.3.6.1.4.1.20044.7.6.4 | Scalarmgnt2RinvAgent | read-write | current | Chassis Software inventory:This OID gives the software inventory of the Mgnt2 management module |
| 1.3.6.1.4.1.20044.7.6.5 | Scalarmgnt2RinvCraft | read-write | current | Chassis Craft inventory:This OID gives the craft inventory of the Mgnt2 management module |
| 1.3.6.1.4.1.20044.7.6.6 | Scalarmgnt2RinvLinux | read-write | current | Chassis Linux inventory:This OID gives the linux inventory of the Mgnt2 management module |
| 1.3.6.1.4.1.20044.7.6.7 | Tablemgnt2GigmPlugInTable | not-accessible | current | List of Plug-ins present |
| 1.3.6.1.4.1.20044.7.6.7.1 | Rowmgnt2GigmPlugInEntry | not-accessible | current | Row Definition for the Plug-ins table |
| 1.3.6.1.4.1.20044.7.6.7.1.1 | Columnmgnt2IndexPlugIns | read-only | current | Index for PMs table |
| 1.3.6.1.4.1.20044.7.6.7.1.2 | Columnmgnt2PlugInRinv | read-only | current | Plug-in RI:This OID gives the remote inventory of the plug-in |
| 1.3.6.1.4.1.20044.7.6.7.1.3 | Columnmgnt2PollingPresent | read-only | current | Polling present:This OID gives the presence of the polling plug-in |
| 1.3.6.1.4.1.20044.7.6.7.1.4 | Columnmgnt2SnmpPresent | read-only | current | Snmp present:This OID gives the presence of the snmp plug-in |
| 1.3.6.1.4.1.20044.7.6.8 | Scalarmgnt2RinvBackpanel | read-write | current | Backpanel inventory:This OID gives the Backpanel inventory of the chassis |
| 1.3.6.1.4.1.20044.7.6.9 | Scalarmgnt2RinvFan | read-write | current | Fan inventory:This OID gives the fan inventory of the chassis |
| 1.3.6.1.4.1.20044.7.6.10 | Scalarmgnt2RinvUboot | read-write | current | U-Boot inventory:This OID gives the U-Boot inventory |
| 1.3.6.1.4.1.20044.7.7 | Nodemgnt2ErrorCounters | |||
| 1.3.6.1.4.1.20044.7.7.1 | Tablemgnt2GigmErrorCounterTable | not-accessible | current | List of error counters |
| 1.3.6.1.4.1.20044.7.7.1.1 | Rowmgnt2GigmErrorCounterEntry | not-accessible | current | Row Definition for the error counters table |
| 1.3.6.1.4.1.20044.7.7.1.1.1 | Columnmgnt2IndexErrorCounter | read-only | current | Index for error counters table |
| 1.3.6.1.4.1.20044.7.7.1.1.2 | Columnmgnt2ErrorCounterSlotNumber | read-only | current | Slot number:This OID gives the slot number for the corresponding counter |
| 1.3.6.1.4.1.20044.7.7.1.1.3 | Columnmgnt2ErrorCounterValue | read-only | current | Count value:This OID gives the value of the error counter |
| 1.3.6.1.4.1.20044.7.7.2 | Scalarmgnt2GigmResetErrorCounters | read-write | current | Reset error counters:This OID reset the error counters to 0 |
| 1.3.6.1.4.1.20044.7.8 | Nodemgnt2Perf | |||
| 1.3.6.1.4.1.20044.7.8.1 | Tablemgnt2PerfCapabilityTable | not-accessible | current | List of Perf capability of PMs plugged in the Chassis |
| 1.3.6.1.4.1.20044.7.8.1.1 | Rowmgnt2PerfCapabilityEntry | not-accessible | current | Row Definition for the Perf capability table |
| 1.3.6.1.4.1.20044.7.8.1.1.1 | Columnmgnt2PerfCapIndexBoards | read-only | current | Index for Perf cap table |
| 1.3.6.1.4.1.20044.7.8.1.1.2 | Columnmgnt2PerfCapPosition | read-only | current | PM Slot number:This OID gives the slot number in which the PM is plugged |
| 1.3.6.1.4.1.20044.7.8.1.1.3 | Columnmgnt2PerfCapName | read-only | current | PM name:This OID gives the name of the PM plugged in the Mgnt2 |
| 1.3.6.1.4.1.20044.7.8.1.1.4 | Columnmgnt2PerfCapStatus | read-only | current | Status of the perf cap:This OID gives the capability of the pm to do performance |
| 1.3.6.1.4.1.20044.7.8.1.1.5 | Columnmgnt2PerfCapOidEnable | read-only | current | OID of the object perf enable:This OID gives the OID of the perf enable object of the correspondind mib of the module |
| 1.3.6.1.4.1.20044.7.8.2 | Scalarmgnt2GigmPerf15minSync | read-write | current | 15 min sync perf : this oid send a 15min sync to all modules |
| 1.3.6.1.4.1.20044.7.8.3 | Scalarmgnt2GigmPerf24hSync | read-write | current | 15 min sync perf : this oid send a 24h sync to all modules |
| 1.3.6.1.4.1.20044.7.8.4 | Scalarmgnt2PerfResyncNMS | read-write | current | Resync Perf : this oid allows to create an historical perf file for all modules |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| EkiPlugInState | INTEGER { absent(0), loaded(1), versionError(2), symbolError(3) } | current | Plug-in state |
| Mgnt2AckMode | INTEGER { modeA(1), modeB(2) } | current | different modes to acknowledge alarms |
| Mgnt2AuthTypeValues | INTEGER { authLocal(0), authRADIUS(1), authLDAP(2) } | current | Various types of authentication processes |
| Mgnt2CraftAccessValues | INTEGER { noCraftAccess(0), craftEnable(1), craftEnableHttps(2) } | current | enables access to the CRAFT |
| Mgnt2DccAccessValues | INTEGER { mode1Slots2s4s6s8s10(0), mode2Slots2s6s10s14s18(1) } | current | different modes for the Dcc access |
| Mgnt2LogFileMode | INTEGER { disabled(0), linear(1), rotary(2) } | current | different modes for the log files |
| Mgnt2MasterEthMode | INTEGER { static(1), dhcp(2) } | current | different modes for the Master |
| Mgnt2NetMode | INTEGER { switch(1), gateway(2) } | current | different modes for the network management |
| Mgnt2NetworkPort | INTEGER { stacking(0), dcn(1), frontrouter(2), edge(3), udcn(4) } | current | different modes for Network Port |
| Mgnt2PerfResyncValues | INTEGER { perfResyncIdle(1), perfResyncSync(2), perfResyncReady(3), perfResyncDelete(4) } | current | different modes for the trap generation |
| Mgnt2RJ45EthernetPortMode | INTEGER { enabled(0), disabled(1) } | current | different modes for RJ45 port disabling |
| Mgnt2SlotStatus | INTEGER { slotEmpty(0), pmReady(1), pmReset(2), pmLoad(3), pmPassive(4), pmUnknown(5), pmNotReady(6) } | current | Status of the slot |
| Mgnt2SubnetEthMode | INTEGER { static(1), dhcp(2) } | current | different modes for the Subnet |
| Mgnt2TrapModeValues | INTEGER { syntheticTrap(0), detailedTrap(1), nmsTrap(2) } | current | different modes for the trap generation |