EKINOPS-Pm124fe-MIB
307 objects
MIB for the Ekinops Pm124FE hardware.
Imported Objects
| EKINOPS-MIB | EkiApiState EkiMeasureType EkiMode ekinops EkiOnOff EkiProtocol EkiState EkiSynchroMode |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.20044.44 | IdentitymodulePm124fe | MIB for the Ekinops Pm124FE hardware. | ||
| 1.3.6.1.4.1.20044.44.2 | Nodepm124fealarms | |||
| 1.3.6.1.4.1.20044.44.2.1 | Nodepm124feAlmOther | |||
| 1.3.6.1.4.1.20044.44.2.1.1 | Nodepm124feAlmOtherNurg | |||
| 1.3.6.1.4.1.20044.44.2.1.1.2 | Nodepm124feAlmsynthAlm2 | |||
| 1.3.6.1.4.1.20044.44.2.1.1.2.1 | Scalarpm124feAlmConfTableSave | read-only | current | PM configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> <Alar… |
| 1.3.6.1.4.1.20044.44.2.1.1.2.2 | Scalarpm124feAlmInvUpload | read-only | current | Inventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.44.2.1.1.2.3 | Scalarpm124feAlmConfTableLoad | read-only | current | PM configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> <Alarmtype> <Pola… |
| 1.3.6.1.4.1.20044.44.2.1.1.2.4 | Scalarpm124feAlmCorrelatOff | read-only | current | Not used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.44.2.1.2 | Nodepm124feAlmOtherUrg | |||
| 1.3.6.1.4.1.20044.44.2.1.3 | Nodepm124feAlmOtherCrit | |||
| 1.3.6.1.4.1.20044.44.2.1.3.0 | Nodepm124feAlmsynthAlm0 | |||
| 1.3.6.1.4.1.20044.44.2.1.3.0.9 | Scalarpm124feAlmModuleGlobFailure | read-only | current | Module Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.44.2.1.3.0.15 | Scalarpm124feAlmDefFuseA | read-only | current | Fuse A fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.44.2.1.3.0.16 | Scalarpm124feAlmDefFuseB | read-only | current | Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb… |
| 1.3.6.1.4.1.20044.44.2.2 | Nodepm124feAlmClient | |||
| 1.3.6.1.4.1.20044.44.2.2.1 | Nodepm124feAlmClientNurg | |||
| 1.3.6.1.4.1.20044.44.2.2.1.32 | Tablepm124feAlmclientSfpWarnDdmTable | not-accessible | current | List of pm124feAlmclientSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1 | Rowpm124feAlmclientSfpWarnDdmEntry | not-accessible | current | Row definition for the pm124feAlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.1 | Columnpm124feAlmclientSfpWarnDdmIndex | read-only | current | Index definition for the pm124feAlmclientSfpWarnDdm table |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.2 | Columnpm124feAlmClientTxPwLowWngPortn | read-only | current | Client SFP Tx Power Low warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CL… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.3 | Columnpm124feAlmClientTxPwrHighWngPortn | read-only | current | Client SFP Tx Power High warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.4 | Columnpm124feAlmClientTxBiasLowWngPortn | read-only | current | Client SFP Bias Low warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.5 | Columnpm124feAlmClientTxBiasHighWngPortn | read-only | current | Client SFP Bias High warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.6 | Columnpm124feAlmClientVccLowWngPortn | read-only | current | Client SFP Power Supply Low warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.7 | Columnpm124feAlmClientVccHighWngPortn | read-only | current | Client SFP Power Supply High warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.8 | Columnpm124feAlmClientTempLowWngPortn | read-only | current | Client SFP Temp Low warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.9 | Columnpm124feAlmClientTempHighWngPortn | read-only | current | Client SFP Temp High warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIEN… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.16 | Columnpm124feAlmClientRxPwrLowWngPortn | read-only | current | Client SFP Rx Power Low warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLI… |
| 1.3.6.1.4.1.20044.44.2.2.1.32.1.17 | Columnpm124feAlmClientRxPwrHighWngPortn | read-only | current | Client SFP Rx Power High warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> C… |
| 1.3.6.1.4.1.20044.44.2.2.2 | Nodepm124feAlmClientUrg | |||
| 1.3.6.1.4.1.20044.44.2.2.2.24 | Tablepm124feAlmclientSfpAlmDdmTable | not-accessible | current | List of pm124feAlmclientSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1 | Rowpm124feAlmclientSfpAlmDdmEntry | not-accessible | current | Row definition for the pm124feAlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.1 | Columnpm124feAlmclientSfpAlmDdmIndex | read-only | current | Index definition for the pm124feAlmclientSfpAlmDdm table |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.2 | Columnpm124feAlmClientTxPwrLowAlaPortn | read-only | current | Client SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_PW… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.3 | Columnpm124feAlmClientClientTxPwrHighAlaPortn | read-only | current | Client SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_CLI… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.4 | Columnpm124feAlmClientTxBiasLowAlaPortn | read-only | current | Client SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.5 | Columnpm124feAlmClientTxBiasHighAlaPortn | read-only | current | Client SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_T… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.6 | Columnpm124feAlmClientVccLowAlaPortn | read-only | current | Client SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_V… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.7 | Columnpm124feAlmClientVccHighAlaPortn | read-only | current | Client SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.8 | Columnpm124feAlmClientTempLowAlaPortn | read-only | current | Client SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_LOW_A… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.9 | Columnpm124feAlmClientTempHighAlaPortn | read-only | current | Client SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_HIG… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.16 | Columnpm124feAlmClientRxPwrLowAlaPortn | read-only | current | Client SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_PWR… |
| 1.3.6.1.4.1.20044.44.2.2.2.24.1.17 | Columnpm124feAlmClientRxPwrHighAlaPortn | read-only | current | Client SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_P… |
| 1.3.6.1.4.1.20044.44.2.2.3 | Nodepm124feAlmClientCrit | |||
| 1.3.6.1.4.1.20044.44.2.2.3.8 | Tablepm124feAlmsynthAlmPortTable | not-accessible | current | List of pm124feAlmsynthAlmPort Article |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1 | Rowpm124feAlmsynthAlmPortEntry | not-accessible | current | Row definition for the pm124feAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.1 | Columnpm124feAlmsynthAlmPortIndex | read-only | current | Index definition for the pm124feAlmsynthAlmPort table |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.2 | Columnpm124feAlmClientSfpAbsentPortn | read-only | current | Client SFP not plugged :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is pres… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.3 | Columnpm124feAlmClientDdmAbsentPortn | read-only | current | DDM supported on client SFP :This OID indicates that the Client SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.5 | Columnpm124feAlmClientHwFailAccPortn | read-only | current | Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL_ACC_1 <Probcause> <Alarmtype> <Polar… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.6 | Columnpm124feAlmClientLsdPortn | read-only | current | Client SFP optical TX ON :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the client transceiver laser is O… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.7 | Columnpm124feAlmClientLocalOosPortn | read-only | current | Local Client port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.8 | Columnpm124feAlmClientRemoteOosPortn | read-only | current | Remote Client port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.9 | Columnpm124feAlmClientDwCaisPortn | read-only | current | Client AIS inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.10 | Columnpm124feAlmClientSfpDdmWarningPortn | read-only | current | Warning on Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte… |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.11 | Columnpm124feAlmClientSfpDdmAlmPortn | read-only | current | Alarm on Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on … |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.13 | Columnpm124feAlmClientFailAccPortn | read-only | current | Client Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL_ACC_1 <Probcause> <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.44.2.2.3.8.1.17 | Columnpm124feAlmClientUpCsfPortn | read-only | current | Client Signal Fail inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu… |
| 1.3.6.1.4.1.20044.44.2.2.3.16 | Tablepm124feAlmclientAccessioAlmTable | not-accessible | current | List of pm124feAlmclientAccessioAlm Article |
| 1.3.6.1.4.1.20044.44.2.2.3.16.1 | Rowpm124feAlmclientAccessioAlmEntry | not-accessible | current | Row definition for the pm124feAlmclientAccessioAlm table |
| 1.3.6.1.4.1.20044.44.2.2.3.16.1.1 | Columnpm124feAlmclientAccessioAlmIndex | read-only | current | Index definition for the pm124feAlmclientAccessioAlm table |
| 1.3.6.1.4.1.20044.44.2.2.3.16.1.2 | Columnpm124feAlmClientLasFailPortn | read-only | current | Client SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm … |
| 1.3.6.1.4.1.20044.44.2.2.3.16.1.5 | Columnpm124feAlmClientLosPortn | read-only | current | Loss of Optical signal on Client :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal i… |
| 1.3.6.1.4.1.20044.44.2.2.3.40 | Tablepm124feAlmclientAccAlmTable | not-accessible | current | List of pm124feAlmclientAccAlm Article |
| 1.3.6.1.4.1.20044.44.2.2.3.40.1 | Rowpm124feAlmclientAccAlmEntry | not-accessible | current | Row definition for the pm124feAlmclientAccAlm table |
| 1.3.6.1.4.1.20044.44.2.2.3.40.1.1 | Columnpm124feAlmclientAccAlmIndex | read-only | current | Index definition for the pm124feAlmclientAccAlm table |
| 1.3.6.1.4.1.20044.44.2.2.3.40.1.2 | Columnpm124feAlmClientOosPortn | read-only | current | Client Loss of synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli… |
| 1.3.6.1.4.1.20044.44.2.2.3.40.1.11 | Columnpm124feAlmClientUpEsOvlPortn | read-only | current | Client Upstream buffer overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u… |
| 1.3.6.1.4.1.20044.44.2.2.3.40.1.12 | Columnpm124feAlmClientCsfDetPortn | read-only | current | Client Signal Fail detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client… |
| 1.3.6.1.4.1.20044.44.2.2.3.40.1.15 | Columnpm124feAlmClientDwEsOvlPortn | read-only | current | Client Downstream buffer overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs… |
| 1.3.6.1.4.1.20044.44.2.3 | Nodepm124feAlmLine | |||
| 1.3.6.1.4.1.20044.44.2.3.1 | Nodepm124feAlmLineNurg | |||
| 1.3.6.1.4.1.20044.44.2.3.1.66 | Tablepm124feAlmlineSfpWarnDdmTable | not-accessible | current | List of pm124feAlmlineSfpWarnDdm Article |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1 | Rowpm124feAlmlineSfpWarnDdmEntry | not-accessible | current | Row definition for the pm124feAlmlineSfpWarnDdm table |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.1 | Columnpm124feAlmlineSfpWarnDdmIndex | read-only | current | Index definition for the pm124feAlmlineSfpWarnDdm table |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.2 | Columnpm124feAlmLineTxPwLowWngPortn | read-only | current | Line SFP Tx Power Low warning :Warning indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.3 | Columnpm124feAlmLineTxPwrHighWngPortn | read-only | current | Line SFP Tx Power High warning :Warning indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.4 | Columnpm124feAlmLineTxBiasLowWngPortn | read-only | current | Line SFP Bias Low warning :Warning indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LI… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.5 | Columnpm124feAlmLineTxBiasHighWngPortn | read-only | current | Line SFP Bias High warning :Warning indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.6 | Columnpm124feAlmLineVccLowWngPortn | read-only | current | Line SFP Power Supply Low warning :Warning indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> … |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.7 | Columnpm124feAlmLineVccHighWngPortn | read-only | current | Line SFP Power Supply High warning :Warning indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.8 | Columnpm124feAlmLineTempLowWngPortn | read-only | current | Line SFP Temp Low warning :Warning indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.9 | Columnpm124feAlmLineTempHighWngPortn | read-only | current | Line SFP Temp High warning :Warning indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TE… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.16 | Columnpm124feAlmLineRxPwrLowWngPortn | read-only | current | Line SFP Rx Power Low warning :Warning indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_… |
| 1.3.6.1.4.1.20044.44.2.3.1.66.1.17 | Columnpm124feAlmLineRxPwrHighWngPortn | read-only | current | Line SFP Rx Power High warning :Warning indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LIN… |
| 1.3.6.1.4.1.20044.44.2.3.2 | Nodepm124feAlmLineUrg | |||
| 1.3.6.1.4.1.20044.44.2.3.2.65 | Tablepm124feAlmlineSfpAlmDdmTable | not-accessible | current | List of pm124feAlmlineSfpAlmDdm Article |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1 | Rowpm124feAlmlineSfpAlmDdmEntry | not-accessible | current | Row definition for the pm124feAlmlineSfpAlmDdm table |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.1 | Columnpm124feAlmlineSfpAlmDdmIndex | read-only | current | Index definition for the pm124feAlmlineSfpAlmDdm table |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.2 | Columnpm124feAlmLineTxPwrLowAlaPortn | read-only | current | Line SFP Tx Power Low :Alarm indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_LO… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.3 | Columnpm124feAlmLineTxPwrHighAlaPortn | read-only | current | Line SFP Tx Power High :Alarm indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.4 | Columnpm124feAlmLineTxBiasLowAlaPortn | read-only | current | Line SFP Bias Low :Alarm indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BIAS… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.5 | Columnpm124feAlmLineTxBiasHighAlaPortn | read-only | current | Line SFP Bias High :Alarm indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BI… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.6 | Columnpm124feAlmLineVccLowAlaPortn | read-only | current | Line SFP Power Supply Low :Alarm indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC_L… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.7 | Columnpm124feAlmLineVccHighAlaPortn | read-only | current | Line SFP Power Supply High :Alarm indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.8 | Columnpm124feAlmLineTempLowAlaPortn | read-only | current | Line SFP Temp Low :Alarm indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_LOW_ALA <… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.9 | Columnpm124feAlmLineTempHighAlaPortn | read-only | current | Line SFP Temp High :Alarm indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_HIGH_AL… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.16 | Columnpm124feAlmLineRxPwrLowAlaPortn | read-only | current | Line SFP Rx Power Low :Alarm indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_LOW… |
| 1.3.6.1.4.1.20044.44.2.3.2.65.1.17 | Columnpm124feAlmLineRxPwrHighAlaPortn | read-only | current | Line SFP Rx Power High :Alarm indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_H… |
| 1.3.6.1.4.1.20044.44.2.3.3 | Nodepm124feAlmLineCrit | |||
| 1.3.6.1.4.1.20044.44.2.3.3.7 | Tablepm124feAlmsynthAlmLineTable | not-accessible | current | List of pm124feAlmsynthAlmLine Article |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1 | Rowpm124feAlmsynthAlmLineEntry | not-accessible | current | Row definition for the pm124feAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.1 | Columnpm124feAlmsynthAlmLineIndex | read-only | current | Index definition for the pm124feAlmsynthAlmLine table |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.2 | Columnpm124feAlmLineSfpAbsentPortn | read-only | current | Line SFP not plugged :This OID indicates that the SFP module is not present in the line port. <Help> This alarm indicates if the line transceiver is present. <… |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.3 | Columnpm124feAlmLineDdmAbsentPortn | read-only | current | DDM supported on Line SFP :This OID indicates that the SFP module on line port does not support Digital Diagnostic Monitoring Functions <Help> This status indi… |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.5 | Columnpm124feAlmLineHwFailPortn | read-only | current | Line HW Fail :This OID indicates a failure condition on the Line port, the most probable cause being a HW issue <Condtype> LINE_HW_FAIL <Probcause> <Alarmtype>… |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.6 | Columnpm124feAlmLineLsdPortn | read-only | current | Line SFP optical TX ON :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the line transceiver laser is ON or… |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.7 | Columnpm124feAlmLineLocalOosPortn | read-only | current | Line port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service… |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.10 | Columnpm124feAlmLineDdmWarningPortn | read-only | current | Warning on Line SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detected … |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.11 | Columnpm124feAlmLineDdmAlmPortn | read-only | current | Alarm on Line SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on th… |
| 1.3.6.1.4.1.20044.44.2.3.3.7.1.13 | Columnpm124feAlmLineFailPortn | read-only | current | Line Fail :This OID indicates a failure on the Client port <Condtype> LINE_FAIL <Probcause> <Alarmtype> <Polarity> (2) |
| 1.3.6.1.4.1.20044.44.2.3.3.64 | Tablepm124feAlmlineAccessioAlmTable | not-accessible | current | List of pm124feAlmlineAccessioAlm Article |
| 1.3.6.1.4.1.20044.44.2.3.3.64.1 | Rowpm124feAlmlineAccessioAlmEntry | not-accessible | current | Row definition for the pm124feAlmlineAccessioAlm table |
| 1.3.6.1.4.1.20044.44.2.3.3.64.1.1 | Columnpm124feAlmlineAccessioAlmIndex | read-only | current | Index definition for the pm124feAlmlineAccessioAlm table |
| 1.3.6.1.4.1.20044.44.2.3.3.64.1.2 | Columnpm124feAlmLineLasFailPortn | read-only | current | Line SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the line port (this alarm reports the transmitter failure alarm gene… |
| 1.3.6.1.4.1.20044.44.2.3.3.64.1.5 | Columnpm124feAlmLineLosPortn | read-only | current | Loss of Optical signal on Line :This OID indicates that no signal is present on the SFP of the line port <Help> This alarm indicates if an optical signal is de… |
| 1.3.6.1.4.1.20044.44.2.3.3.64.1.7 | Columnpm124feAlmLineLossSyncPortn | read-only | current | Line Loss of 10b/8b Sync :This OID indicates the upstream line input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if the in… |
| 1.3.6.1.4.1.20044.44.3 | Nodepm124femeasures | |||
| 1.3.6.1.4.1.20044.44.3.1 | Nodepm124feMesrOther | |||
| 1.3.6.1.4.1.20044.44.3.2 | Nodepm124feMesrClient | |||
| 1.3.6.1.4.1.20044.44.3.2.16 | Tablepm124feMesrclientTemperatureTable | not-accessible | current | List of pm124feMesrclientTemperature Article |
| 1.3.6.1.4.1.20044.44.3.2.16.1 | Rowpm124feMesrclientTemperatureEntry | not-accessible | current | Row definition for the pm124feMesrclientTemperature table |
| 1.3.6.1.4.1.20044.44.3.2.16.1.1 | Columnpm124feMesrclientTemperatureIndex | read-only | current | Index definition for the pm124feMesrclientTemperature table |
| 1.3.6.1.4.1.20044.44.3.2.16.1.2 | Columnpm124feMesrclientTemperaturePortn | read-only | current | Client SFP Temperature :This OID gives the temperature value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit … |
| 1.3.6.1.4.1.20044.44.3.2.24 | Tablepm124feMesrclientVoltTable | not-accessible | current | List of pm124feMesrclientVolt Article |
| 1.3.6.1.4.1.20044.44.3.2.24.1 | Rowpm124feMesrclientVoltEntry | not-accessible | current | Row definition for the pm124feMesrclientVolt table |
| 1.3.6.1.4.1.20044.44.3.2.24.1.1 | Columnpm124feMesrclientVoltIndex | read-only | current | Index definition for the pm124feMesrclientVolt table |
| 1.3.6.1.4.1.20044.44.3.2.24.1.2 | Columnpm124feMesrclientVoltPortn | read-only | current | Client SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100… |
| 1.3.6.1.4.1.20044.44.3.2.32 | Tablepm124feMesrclientTxBiasTable | not-accessible | current | List of pm124feMesrclientTxBias Article |
| 1.3.6.1.4.1.20044.44.3.2.32.1 | Rowpm124feMesrclientTxBiasEntry | not-accessible | current | Row definition for the pm124feMesrclientTxBias table |
| 1.3.6.1.4.1.20044.44.3.2.32.1.1 | Columnpm124feMesrclientTxBiasIndex | read-only | current | Index definition for the pm124feMesrclientTxBias table |
| 1.3.6.1.4.1.20044.44.3.2.32.1.2 | Columnpm124feMesrclientTxBiasPortn | read-only | current | Client SFP Laser Bias :This OID gives the bias value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> Th… |
| 1.3.6.1.4.1.20044.44.3.2.40 | Tablepm124feMesrclientTxPowerTable | not-accessible | current | List of pm124feMesrclientTxPower Article |
| 1.3.6.1.4.1.20044.44.3.2.40.1 | Rowpm124feMesrclientTxPowerEntry | not-accessible | current | Row definition for the pm124feMesrclientTxPower table |
| 1.3.6.1.4.1.20044.44.3.2.40.1.1 | Columnpm124feMesrclientTxPowerIndex | read-only | current | Index definition for the pm124feMesrclientTxPower table |
| 1.3.6.1.4.1.20044.44.3.2.40.1.2 | Columnpm124feMesrclientTxPowerPortn | read-only | current | Client SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-… |
| 1.3.6.1.4.1.20044.44.3.2.48 | Tablepm124feMesrclientRxPowerTable | not-accessible | current | List of pm124feMesrclientRxPower Article |
| 1.3.6.1.4.1.20044.44.3.2.48.1 | Rowpm124feMesrclientRxPowerEntry | not-accessible | current | Row definition for the pm124feMesrclientRxPower table |
| 1.3.6.1.4.1.20044.44.3.2.48.1.1 | Columnpm124feMesrclientRxPowerIndex | read-only | current | Index definition for the pm124feMesrclientRxPower table |
| 1.3.6.1.4.1.20044.44.3.2.48.1.2 | Columnpm124feMesrclientRxPowerPortn | read-only | current | Client SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (U… |
| 1.3.6.1.4.1.20044.44.3.3 | Nodepm124feMesrLine | |||
| 1.3.6.1.4.1.20044.44.3.3.64 | Tablepm124feMesrlineTemperatureTable | not-accessible | current | List of pm124feMesrlineTemperature Article |
| 1.3.6.1.4.1.20044.44.3.3.64.1 | Rowpm124feMesrlineTemperatureEntry | not-accessible | current | Row definition for the pm124feMesrlineTemperature table |
| 1.3.6.1.4.1.20044.44.3.3.64.1.1 | Columnpm124feMesrlineTemperatureIndex | read-only | current | Index definition for the pm124feMesrlineTemperature table |
| 1.3.6.1.4.1.20044.44.3.3.64.1.2 | Columnpm124feMesrlineTemperaturePortn | read-only | current | Line SFP Temperature :This OID gives the temperature value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C)… |
| 1.3.6.1.4.1.20044.44.3.3.65 | Tablepm124feMesrlineVoltTable | not-accessible | current | List of pm124feMesrlineVolt Article |
| 1.3.6.1.4.1.20044.44.3.3.65.1 | Rowpm124feMesrlineVoltEntry | not-accessible | current | Row definition for the pm124feMesrlineVolt table |
| 1.3.6.1.4.1.20044.44.3.3.65.1.1 | Columnpm124feMesrlineVoltIndex | read-only | current | Index definition for the pm124feMesrlineVolt table |
| 1.3.6.1.4.1.20044.44.3.3.65.1.2 | Columnpm124feMesrlineVoltPortn | read-only | current | Line SFP Power Supply :This OID gives the 3V3 voltage value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) … |
| 1.3.6.1.4.1.20044.44.3.3.66 | Tablepm124feMesrlineTxBiasTable | not-accessible | current | List of pm124feMesrlineTxBias Article |
| 1.3.6.1.4.1.20044.44.3.3.66.1 | Rowpm124feMesrlineTxBiasEntry | not-accessible | current | Row definition for the pm124feMesrlineTxBias table |
| 1.3.6.1.4.1.20044.44.3.3.66.1.1 | Columnpm124feMesrlineTxBiasIndex | read-only | current | Index definition for the pm124feMesrlineTxBias table |
| 1.3.6.1.4.1.20044.44.3.3.66.1.2 | Columnpm124feMesrlineTxBiasPortn | read-only | current | Line SFP Laser Bias :This OID gives the bias value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This m… |
| 1.3.6.1.4.1.20044.44.3.3.67 | Tablepm124feMesrlineTxPowerTable | not-accessible | current | List of pm124feMesrlineTxPower Article |
| 1.3.6.1.4.1.20044.44.3.3.67.1 | Rowpm124feMesrlineTxPowerEntry | not-accessible | current | Row definition for the pm124feMesrlineTxPower table |
| 1.3.6.1.4.1.20044.44.3.3.67.1.1 | Columnpm124feMesrlineTxPowerIndex | read-only | current | Index definition for the pm124feMesrlineTxPower table |
| 1.3.6.1.4.1.20044.44.3.3.67.1.2 | Columnpm124feMesrlineTxPowerPortn | read-only | current | Line SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) … |
| 1.3.6.1.4.1.20044.44.3.3.68 | Tablepm124feMesrlineRxPowerTable | not-accessible | current | List of pm124feMesrlineRxPower Article |
| 1.3.6.1.4.1.20044.44.3.3.68.1 | Rowpm124feMesrlineRxPowerEntry | not-accessible | current | Row definition for the pm124feMesrlineRxPower table |
| 1.3.6.1.4.1.20044.44.3.3.68.1.1 | Columnpm124feMesrlineRxPowerIndex | read-only | current | Index definition for the pm124feMesrlineRxPower table |
| 1.3.6.1.4.1.20044.44.3.3.68.1.2 | Columnpm124feMesrlineRxPowerPortn | read-only | current | Line SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit … |
| 1.3.6.1.4.1.20044.44.4 | Nodepm124fecounters | |||
| 1.3.6.1.4.1.20044.44.4.1 | Nodepm124feCntOther | |||
| 1.3.6.1.4.1.20044.44.4.2 | Nodepm124feCntClient | |||
| 1.3.6.1.4.1.20044.44.4.2.16 | Tablepm124feCntclientCbipErrCntTable | not-accessible | current | List of pm124feCntclientCbipErrCnt Article |
| 1.3.6.1.4.1.20044.44.4.2.16.1 | Rowpm124feCntclientCbipErrCntEntry | not-accessible | current | Row definition for the pm124feCntclientCbipErrCnt table |
| 1.3.6.1.4.1.20044.44.4.2.16.1.1 | Columnpm124feCntclientCbipErrCntIndex | read-only | current | Index definition for the pm124feCntclientCbipErrCnt table |
| 1.3.6.1.4.1.20044.44.4.2.16.1.2 | Columnpm124feCntclientCbipErrCntValuePortn | read-only | current | Client CBIP errors (Err Sec) :This counter is incremented by one each time one or several CBIP parity error is detected during one second on the client output … |
| 1.3.6.1.4.1.20044.44.4.2.16.1.3 | Columnpm124feCntclientCbipErrCntErrorPortn | read-only | current | Client CBIP counter error :This OID when set indicates the CBIP error counter value is invalid on Port |
| 1.3.6.1.4.1.20044.44.4.2.16.1.4 | Columnpm124feCntclientCbipErrCntOverloadPortn | read-only | current | Client CBIP counter overload :This OID when set indicates a CBIP error counter overload on Port |
| 1.3.6.1.4.1.20044.44.4.2.24 | Tablepm124feCntclientFcsErrCntTable | not-accessible | current | List of pm124feCntclientFcsErrCnt Article |
| 1.3.6.1.4.1.20044.44.4.2.24.1 | Rowpm124feCntclientFcsErrCntEntry | not-accessible | current | Row definition for the pm124feCntclientFcsErrCnt table |
| 1.3.6.1.4.1.20044.44.4.2.24.1.1 | Columnpm124feCntclientFcsErrCntIndex | read-only | current | Index definition for the pm124feCntclientFcsErrCnt table |
| 1.3.6.1.4.1.20044.44.4.2.24.1.2 | Columnpm124feCntclientFcsErrCntValuePortn | read-only | current | Client FCS errors (Err Sec) :This counter is incremented by one each time one or several FCS error is detected during one second on the client input stream. <H… |
| 1.3.6.1.4.1.20044.44.4.2.24.1.3 | Columnpm124feCntclientFcsErrCntErrorPortn | read-only | current | Client B1 counter error :This OID when set indicates the B1 counter value is invalid on Port |
| 1.3.6.1.4.1.20044.44.4.2.24.1.4 | Columnpm124feCntclientFcsErrCntOverloadPortn | read-only | current | Client B1 counter overload :This OID when set indicates a B1 counter overload on Port |
| 1.3.6.1.4.1.20044.44.4.3 | Nodepm124feCntLine | |||
| 1.3.6.1.4.1.20044.44.4.3.64 | Tablepm124feCntlineDispErrCntTable | not-accessible | current | List of pm124feCntlineDispErrCnt Article |
| 1.3.6.1.4.1.20044.44.4.3.64.1 | Rowpm124feCntlineDispErrCntEntry | not-accessible | current | Row definition for the pm124feCntlineDispErrCnt table |
| 1.3.6.1.4.1.20044.44.4.3.64.1.1 | Columnpm124feCntlineDispErrCntIndex | read-only | current | Index definition for the pm124feCntlineDispErrCnt table |
| 1.3.6.1.4.1.20044.44.4.3.64.1.2 | Columnpm124feCntlineDispErrCntValuePortn | read-only | current | Line RD errors (Err Sec) :This counter is in incremented by one each time one or several 10b/8b running disparity error is detected during one second on the Li… |
| 1.3.6.1.4.1.20044.44.4.3.64.1.3 | Columnpm124feCntlineDispErrCntErrorPortn | read-only | current | Line counter error :This OID when set indicates the line error counter value is invalid on Line |
| 1.3.6.1.4.1.20044.44.4.3.64.1.4 | Columnpm124feCntlineDispErrCntOverloadPortn | read-only | current | Line counter overload :This OID when set indicates a line input error counter overload on Line |
| 1.3.6.1.4.1.20044.44.4.3.65 | Tablepm124feCntlineCrcErrCntTable | not-accessible | current | List of pm124feCntlineCrcErrCnt Article |
| 1.3.6.1.4.1.20044.44.4.3.65.1 | Rowpm124feCntlineCrcErrCntEntry | not-accessible | current | Row definition for the pm124feCntlineCrcErrCnt table |
| 1.3.6.1.4.1.20044.44.4.3.65.1.1 | Columnpm124feCntlineCrcErrCntIndex | read-only | current | Index definition for the pm124feCntlineCrcErrCnt table |
| 1.3.6.1.4.1.20044.44.4.3.65.1.2 | Columnpm124feCntlineCrcErrCntValuePortn | read-only | current | Line CRC errors (Err Sec) :This counter is incremented by one each time one or several CRC error is detected during one second on the Line port <Help> This cou… |
| 1.3.6.1.4.1.20044.44.4.3.65.1.3 | Columnpm124feCntlineCrcErrCntErrorPortn | read-only | current | CRC Errors counter error :This OID when set indicates the CRC Errors counter value is invalid on line port |
| 1.3.6.1.4.1.20044.44.4.3.65.1.4 | Columnpm124feCntlineCrcErrCntOverloadPortn | read-only | current | CRC Errors counter overload :This OID when set indicates a CRC Errors counter overload on line port |
| 1.3.6.1.4.1.20044.44.4.259 | Scalarpm124feCntCountersReset | read-write | current | Counters Reset:This OID resets and restarts all the counters |
| 1.3.6.1.4.1.20044.44.4.260 | Scalarpm124feCntCountersStop | read-write | current | Counters stop:This OID stops all the counters |
| 1.3.6.1.4.1.20044.44.6 | Nodepm124fecontrolsWrite | |||
| 1.3.6.1.4.1.20044.44.6.1 | Nodepm124feCtrlOther | |||
| 1.3.6.1.4.1.20044.44.6.1.0 | Nodepm124feCtrlsynth0 | |||
| 1.3.6.1.4.1.20044.44.6.1.0.1 | Scalarpm124feCtrlConfLoad | read-write | current | Load Configuration Tables :When set this enables loading from flash configuration1 into the module. |
| 1.3.6.1.4.1.20044.44.6.1.0.9 | Scalarpm124feCtrlConfFlash | read-write | current | Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config… |
| 1.3.6.1.4.1.20044.44.6.1.0.13 | Scalarpm124feCtrlConfClear | read-write | current | Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of… |
| 1.3.6.1.4.1.20044.44.6.1.4 | Nodepm124feCtrlsynth4 | |||
| 1.3.6.1.4.1.20044.44.6.1.4.1 | Scalarpm124feCtrlCorrelatOn | read-write | current | Enable Alarm Correlation :This OID enables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.44.6.1.4.2 | Scalarpm124feCtrlCorrelatOff | read-write | current | Disable Alarm Correlation :This OID disables the alarm correlation in the PM. |
| 1.3.6.1.4.1.20044.44.6.1.5 | Nodepm124feCtrlswMgnt | |||
| 1.3.6.1.4.1.20044.44.6.1.5.2 | Scalarpm124feCtrlColdReset | read-write | current | PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start… |
| 1.3.6.1.4.1.20044.44.6.1.5.3 | Scalarpm124feCtrlWarmReset | read-write | current | PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch… |
| 1.3.6.1.4.1.20044.44.6.1.72 | Nodepm124feCtrlledTest | |||
| 1.3.6.1.4.1.20044.44.6.1.72.1 | Scalarpm124feCtrlGreenLed | read-write | current | Green Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green |
| 1.3.6.1.4.1.20044.44.6.1.72.2 | Scalarpm124feCtrlRedLed | read-write | current | Red Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red |
| 1.3.6.1.4.1.20044.44.6.1.72.3 | Scalarpm124feCtrlLedOff | read-write | current | Leds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF |
| 1.3.6.1.4.1.20044.44.6.1.73 | Nodepm124feCtrlmoduleOosMode | |||
| 1.3.6.1.4.1.20044.44.6.1.73.1 | Scalarpm124feCtrlModuleOosMode | read-write | current | PM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module |
| 1.3.6.1.4.1.20044.44.6.2 | Nodepm124feCtrlClient | |||
| 1.3.6.1.4.1.20044.44.6.2.16 | Tablepm124feCtrlclientSfpOnoffTable | not-accessible | current | List of pm124feCtrlclientSfpOnoff Article |
| 1.3.6.1.4.1.20044.44.6.2.16.1 | Rowpm124feCtrlclientSfpOnoffEntry | not-accessible | current | Row definition for the pm124feCtrlclientSfpOnoff table |
| 1.3.6.1.4.1.20044.44.6.2.16.1.1 | Columnpm124feCtrlclientSfpOnoffIndex | read-only | current | Index definition for the pm124feCtrlclientSfpOnoff table |
| 1.3.6.1.4.1.20044.44.6.2.16.1.2 | Columnpm124feCtrlclientSfpOnoffPortn | read-write | current | SFP OFF (100 Base Sx only) :This OID switches off the clients SFP <Help> This control defines the laser state of the client transceiver |
| 1.3.6.1.4.1.20044.44.6.2.17 | Tablepm124feCtrlclientLoopTable | not-accessible | current | List of pm124feCtrlclientLoop Article |
| 1.3.6.1.4.1.20044.44.6.2.17.1 | Rowpm124feCtrlclientLoopEntry | not-accessible | current | Row definition for the pm124feCtrlclientLoop table |
| 1.3.6.1.4.1.20044.44.6.2.17.1.1 | Columnpm124feCtrlclientLoopIndex | read-only | current | Index definition for the pm124feCtrlclientLoop table |
| 1.3.6.1.4.1.20044.44.6.2.17.1.2 | Columnpm124feCtrlclientLoopPortn | read-write | current | Client Access Loop Back :This OID operates an access loopback on the Client port. <Help> This control defines the access loop back of the client port |
| 1.3.6.1.4.1.20044.44.6.2.18 | Tablepm124feCtrlclientCsfUpInsertTable | not-accessible | current | List of pm124feCtrlclientCsfUpInsert Article |
| 1.3.6.1.4.1.20044.44.6.2.18.1 | Rowpm124feCtrlclientCsfUpInsertEntry | not-accessible | current | Row definition for the pm124feCtrlclientCsfUpInsert table |
| 1.3.6.1.4.1.20044.44.6.2.18.1.1 | Columnpm124feCtrlclientCsfUpInsertIndex | read-only | current | Index definition for the pm124feCtrlclientCsfUpInsert table |
| 1.3.6.1.4.1.20044.44.6.2.18.1.2 | Columnpm124feCtrlclientCsfUpInsertPortn | read-write | current | Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. |
| 1.3.6.1.4.1.20044.44.6.2.19 | Tablepm124feCtrlclientCaisDwInsertTable | not-accessible | current | List of pm124feCtrlclientCaisDwInsert Article |
| 1.3.6.1.4.1.20044.44.6.2.19.1 | Rowpm124feCtrlclientCaisDwInsertEntry | not-accessible | current | Row definition for the pm124feCtrlclientCaisDwInsert table |
| 1.3.6.1.4.1.20044.44.6.2.19.1.1 | Columnpm124feCtrlclientCaisDwInsertIndex | read-only | current | Index definition for the pm124feCtrlclientCaisDwInsert table |
| 1.3.6.1.4.1.20044.44.6.2.19.1.2 | Columnpm124feCtrlclientCaisDwInsertPortn | read-write | current | Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. |
| 1.3.6.1.4.1.20044.44.6.2.20 | Tablepm124feCtrlclientOosModeTable | not-accessible | current | List of pm124feCtrlclientOosMode Article |
| 1.3.6.1.4.1.20044.44.6.2.20.1 | Rowpm124feCtrlclientOosModeEntry | not-accessible | current | Row definition for the pm124feCtrlclientOosMode table |
| 1.3.6.1.4.1.20044.44.6.2.20.1.1 | Columnpm124feCtrlclientOosModeIndex | read-only | current | Index definition for the pm124feCtrlclientOosMode table |
| 1.3.6.1.4.1.20044.44.6.2.20.1.2 | Columnpm124feCtrlclientOosModePortn | read-write | current | Client port Out of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port |
| 1.3.6.1.4.1.20044.44.6.3 | Nodepm124feCtrlLine | |||
| 1.3.6.1.4.1.20044.44.6.3.64 | Tablepm124feCtrllineSfpOnoffTable | not-accessible | current | List of pm124feCtrllineSfpOnoff Article |
| 1.3.6.1.4.1.20044.44.6.3.64.1 | Rowpm124feCtrllineSfpOnoffEntry | not-accessible | current | Row definition for the pm124feCtrllineSfpOnoff table |
| 1.3.6.1.4.1.20044.44.6.3.64.1.1 | Columnpm124feCtrllineSfpOnoffIndex | read-only | current | Index definition for the pm124feCtrllineSfpOnoff table |
| 1.3.6.1.4.1.20044.44.6.3.64.1.2 | Columnpm124feCtrllineSfpOnoffPortn | read-write | current | Line SFP Optical Output Shut Down :This OID switches off the line SFP <Help> This control defines the laser state of the line transceiver |
| 1.3.6.1.4.1.20044.44.6.3.65 | Tablepm124feCtrllineOosModeTable | not-accessible | current | List of pm124feCtrllineOosMode Article |
| 1.3.6.1.4.1.20044.44.6.3.65.1 | Rowpm124feCtrllineOosModeEntry | not-accessible | current | Row definition for the pm124feCtrllineOosMode table |
| 1.3.6.1.4.1.20044.44.6.3.65.1.1 | Columnpm124feCtrllineOosModeIndex | read-only | current | Index definition for the pm124feCtrllineOosMode table |
| 1.3.6.1.4.1.20044.44.6.3.65.1.2 | Columnpm124feCtrllineOosModePortn | read-write | current | Line port Out of Service :This OID sets the line port Out Of Service <Help> This controls defines the service state of the line port |
| 1.3.6.1.4.1.20044.44.6.3.66 | Tablepm124feCtrllineLoopTable | not-accessible | current | List of pm124feCtrllineLoop Article |
| 1.3.6.1.4.1.20044.44.6.3.66.1 | Rowpm124feCtrllineLoopEntry | not-accessible | current | Row definition for the pm124feCtrllineLoop table |
| 1.3.6.1.4.1.20044.44.6.3.66.1.1 | Columnpm124feCtrllineLoopIndex | read-only | current | Index definition for the pm124feCtrllineLoop table |
| 1.3.6.1.4.1.20044.44.6.3.66.1.2 | Columnpm124feCtrllineLoopPortn | read-write | current | Line Access Loop Back :This OID operates an access loopback on the line port. <Help> This control defines the access loop back of the line port |
| 1.3.6.1.4.1.20044.44.7 | Nodepm124feri | |||
| 1.3.6.1.4.1.20044.44.7.1 | Nodepm124feriTable | |||
| 1.3.6.1.4.1.20044.44.7.1.1 | Tablepm124feRinvClientTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.44.7.1.1.1 | Rowpm124feRinvClientEntry | not-accessible | current | Row definition for the Client SFP table |
| 1.3.6.1.4.1.20044.44.7.1.1.1.1 | Columnpm124feRinvClientIndex | read-only | current | Index for Client SFP table |
| 1.3.6.1.4.1.20044.44.7.1.1.1.2 | Columnpm124feRinvSfpClient | read-only | current | Inventory for the SFP: This OID contains the inventory for the Client SFP |
| 1.3.6.1.4.1.20044.44.7.1.2 | Tablepm124feRinvLineTable | not-accessible | current | List of the SFPs on the selected module |
| 1.3.6.1.4.1.20044.44.7.1.2.1 | Rowpm124feRinvLineEntry | not-accessible | current | Row definition for the Line SFP table |
| 1.3.6.1.4.1.20044.44.7.1.2.1.1 | Columnpm124feRinvLineIndex | read-only | current | Index for SFP table |
| 1.3.6.1.4.1.20044.44.7.1.2.1.2 | Columnpm124feRinvsfpLine | read-only | current | Inventory for the SFP: This OID contains the inventory for the Line SFP |
| 1.3.6.1.4.1.20044.44.7.2 | Scalarpm124feRinvReloadInventory | read-write | current | Reload the inventory: This OID triggers an inventory reload. |
| 1.3.6.1.4.1.20044.44.7.3 | Scalarpm124feRinvHwPlatform | read-only | current | HW platform description: This OID contains the description of the Hardware platform. |
| 1.3.6.1.4.1.20044.44.7.4 | Scalarpm124feRinvModulePlatform | read-only | current | Module platform description: This OID contains the description of the Module. |
| 1.3.6.1.4.1.20044.44.7.5 | Scalarpm124feRinvSwPlatform | read-only | current | SW platform description: This OID contains the description of the Software platform. |
| 1.3.6.1.4.1.20044.44.7.6 | Scalarpm124feRinvGwPlatform | read-only | current | GW platform desciption: This OID contains the description of the Gateware platform. |
| 1.3.6.1.4.1.20044.44.9 | Nodepm124feConfig | |||
| 1.3.6.1.4.1.20044.44.9.1 | Nodepm124feCfgLsd | |||
| 1.3.6.1.4.1.20044.44.9.1.1 | Tablepm124feCfgClientLsdTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.44.9.1.1.1 | Rowpm124feCfgClientLsdEntry | not-accessible | current | Row definition for the lsd table |
| 1.3.6.1.4.1.20044.44.9.1.1.1.1 | Columnpm124feCfgClientLsdIndex | read-only | current | Index definition for the clientLsd table |
| 1.3.6.1.4.1.20044.44.9.1.1.1.3 | Columnpm124feCfgClientLsdModePortn | read-write | current | CAIS mode on Client Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port |
| 1.3.6.1.4.1.20044.44.9.1.1.1.4 | Columnpm124feCfgClientAccessioCtrbInsPortn | read-write | current | CSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.44.9.1.1.1.5 | Columnpm124feCfgClientAccCtrbInsPortn | read-write | current | CSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.44.9.1.1.1.6 | Columnpm124feCfgLineAccessioCtrbInsPortn | read-write | current | CSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.44.9.1.1.1.8 | Columnpm124feCfgClientAccCtrbActPortn | read-write | current | CAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.44.9.1.1.1.9 | Columnpm124feCfgLineAccessioCtrbActPortn | read-write | current | CAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port |
| 1.3.6.1.4.1.20044.44.9.2 | Nodepm124feCfgStartUp | |||
| 1.3.6.1.4.1.20044.44.9.2.1 | Tablepm124feCfgClientStartupTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.44.9.2.1.1 | Rowpm124feCfgClientStartupEntry | not-accessible | current | Row definition for the startUp table |
| 1.3.6.1.4.1.20044.44.9.2.1.1.1 | Columnpm124feCfgClientStartupIndex | read-only | current | Index definition for the clientStartup table |
| 1.3.6.1.4.1.20044.44.9.2.1.1.3 | Columnpm124feCfgClientTrscvCtrlPortn | read-write | current | Default Settings on client TRSCV :This register configures the default initialisation settings on client transceiver. |
| 1.3.6.1.4.1.20044.44.9.2.1.1.5 | Columnpm124feCfgClientOosModePortn | read-write | current | Default Settings on client TRSCV :This register configures the default initialisation settings on client transceiver. |
| 1.3.6.1.4.1.20044.44.9.2.2 | Nodepm124fetablelineStartup | |||
| 1.3.6.1.4.1.20044.44.9.2.2.2 | Scalarpm124feCfglineTrscvCtrl | read-write | current | Default Settings on line TRSCV :This register configures the default initialisation settings on line transceiver. |
| 1.3.6.1.4.1.20044.44.9.2.2.3 | Scalarpm124feCfglineOosMode | read-write | current | Default Settings on line TRSCV :This register configures the default initialisation settings on line transceiver. |
| 1.3.6.1.4.1.20044.44.9.3 | Nodepm124feCfgLabels | |||
| 1.3.6.1.4.1.20044.44.9.3.1 | Tablepm124feCfgLabelclientTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.44.9.3.1.1 | Rowpm124feCfgLabelclientEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.44.9.3.1.1.1 | Columnpm124feCfgLabelclientIndex | read-only | current | Index definition for the labelclient table |
| 1.3.6.1.4.1.20044.44.9.3.1.1.3 | Columnpm124feCfgLabelclientPortn | read-write | current | Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
| 1.3.6.1.4.1.20044.44.9.3.2 | Tablepm124feCfgLabellineTable | not-accessible | current | List of Article |
| 1.3.6.1.4.1.20044.44.9.3.2.1 | Rowpm124feCfgLabellineEntry | not-accessible | current | Row definition for the labels table |
| 1.3.6.1.4.1.20044.44.9.3.2.1.1 | Columnpm124feCfgLabellineIndex | read-only | current | Index definition for the labelline table |
| 1.3.6.1.4.1.20044.44.9.3.2.1.3 | Columnpm124feCfgLabellinePortn | read-write | current | Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. |
| 1.3.6.1.4.1.20044.44.9.257 | Scalarpm124feCfgWriteConfiguration | read-write | current | Write configuration to module:This OID writes the complete configuration to the module |
| 1.3.6.1.4.1.20044.44.10 | Nodepm124fetraps | |||
| 1.3.6.1.4.1.20044.44.10.2 | Scalarpm124fetrapPortNumber | read-only | current | Last port which generates a trap |
| 1.3.6.1.4.1.20044.44.10.3 | Scalarpm124fetrapLineNumber | read-only | current | Last Line which generates a trap |
| 1.3.6.1.4.1.20044.44.10.4 | Scalarpm124fetrapBoardNumber | read-only | current | Last module which generates a trap |
| 1.3.6.1.4.1.20044.44.10.30 | Notificationpm124feLineTrapNotUrgentGoesOn | current | Not urgent Line default is activated | |
| 1.3.6.1.4.1.20044.44.10.31 | Notificationpm124feLineTrapNotUrgentGoesOff | current | Not urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.44.10.32 | Notificationpm124feLineTrapUrgentGoesOn | current | Urgent Line default is activated | |
| 1.3.6.1.4.1.20044.44.10.33 | Notificationpm124feLineTrapUrgentGoesOff | current | Urgent Line default disappeared | |
| 1.3.6.1.4.1.20044.44.10.34 | Notificationpm124feLineTrapCritGoesOn | current | Critical Line default is activated | |
| 1.3.6.1.4.1.20044.44.10.35 | Notificationpm124feLineTrapCritGoesOff | current | Critical Line default disappeared | |
| 1.3.6.1.4.1.20044.44.10.40 | Notificationpm124feClientTrapNotUrgentGoesOn | current | Not urgent client default is activated | |
| 1.3.6.1.4.1.20044.44.10.41 | Notificationpm124feClientTrapNotUrgentGoesOff | current | Not urgent client default disappeared | |
| 1.3.6.1.4.1.20044.44.10.42 | Notificationpm124feClientTrapUrgentGoesOn | current | Urgent client default is activated | |
| 1.3.6.1.4.1.20044.44.10.43 | Notificationpm124feClientTrapUrgentGoesOff | current | Urgent client default disappeared | |
| 1.3.6.1.4.1.20044.44.10.44 | Notificationpm124feClientTrapCritGoesOn | current | Critical client default is activated | |
| 1.3.6.1.4.1.20044.44.10.45 | Notificationpm124feClientTrapCritGoesOff | current | Critical client default disappeared | |
| 1.3.6.1.4.1.20044.44.10.50 | Notificationpm124fePowerTrapUrgentGoesOn | current | Urgent power supply default is activated | |
| 1.3.6.1.4.1.20044.44.10.51 | Notificationpm124fePowerTrapUrgentGoesOff | current | Urgent power supply default disappeared |