EKINOPS-Pm124fe-MIB

307 objects
MIB for the Ekinops Pm124FE hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.44IdentitymodulePm124feMIB for the Ekinops Pm124FE hardware.
1.3.6.1.4.1.20044.44.2Nodepm124fealarms
1.3.6.1.4.1.20044.44.2.1Nodepm124feAlmOther
1.3.6.1.4.1.20044.44.2.1.1Nodepm124feAlmOtherNurg
1.3.6.1.4.1.20044.44.2.1.1.2Nodepm124feAlmsynthAlm2
1.3.6.1.4.1.20044.44.2.1.1.2.1Scalarpm124feAlmConfTableSaveread-onlycurrentPM configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> <Alar…
1.3.6.1.4.1.20044.44.2.1.1.2.2Scalarpm124feAlmInvUploadread-onlycurrentInventory Upload :This OID is at 1 during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.44.2.1.1.2.3Scalarpm124feAlmConfTableLoadread-onlycurrentPM configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. <Condtype> CONF_TABLE_LOAD <Probcause> <Alarmtype> <Pola…
1.3.6.1.4.1.20044.44.2.1.1.2.4Scalarpm124feAlmCorrelatOffread-onlycurrentNot used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.44.2.1.2Nodepm124feAlmOtherUrg
1.3.6.1.4.1.20044.44.2.1.3Nodepm124feAlmOtherCrit
1.3.6.1.4.1.20044.44.2.1.3.0Nodepm124feAlmsynthAlm0
1.3.6.1.4.1.20044.44.2.1.3.0.9Scalarpm124feAlmModuleGlobFailureread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MODULE_GLOB_FAILURE <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.44.2.1.3.0.15Scalarpm124feAlmDefFuseAread-onlycurrentFuse A fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.44.2.1.3.0.16Scalarpm124feAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.44.2.2Nodepm124feAlmClient
1.3.6.1.4.1.20044.44.2.2.1Nodepm124feAlmClientNurg
1.3.6.1.4.1.20044.44.2.2.1.32Tablepm124feAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm124feAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.44.2.2.1.32.1Rowpm124feAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm124feAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.44.2.2.1.32.1.1Columnpm124feAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm124feAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.44.2.2.1.32.1.2Columnpm124feAlmClientTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CL…
1.3.6.1.4.1.20044.44.2.2.1.32.1.3Columnpm124feAlmClientTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.44.2.2.1.32.1.4Columnpm124feAlmClientTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.44.2.2.1.32.1.5Columnpm124feAlmClientTxBiasHighWngPortnread-onlycurrentClient SFP Bias High warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.44.2.2.1.32.1.6Columnpm124feAlmClientVccLowWngPortnread-onlycurrentClient SFP Power Supply Low warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.44.2.2.1.32.1.7Columnpm124feAlmClientVccHighWngPortnread-onlycurrentClient SFP Power Supply High warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.44.2.2.1.32.1.8Columnpm124feAlmClientTempLowWngPortnread-onlycurrentClient SFP Temp Low warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_…
1.3.6.1.4.1.20044.44.2.2.1.32.1.9Columnpm124feAlmClientTempHighWngPortnread-onlycurrentClient SFP Temp High warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIEN…
1.3.6.1.4.1.20044.44.2.2.1.32.1.16Columnpm124feAlmClientRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLI…
1.3.6.1.4.1.20044.44.2.2.1.32.1.17Columnpm124feAlmClientRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> C…
1.3.6.1.4.1.20044.44.2.2.2Nodepm124feAlmClientUrg
1.3.6.1.4.1.20044.44.2.2.2.24Tablepm124feAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm124feAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.44.2.2.2.24.1Rowpm124feAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm124feAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.44.2.2.2.24.1.1Columnpm124feAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm124feAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.44.2.2.2.24.1.2Columnpm124feAlmClientTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_PW…
1.3.6.1.4.1.20044.44.2.2.2.24.1.3Columnpm124feAlmClientClientTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_CLI…
1.3.6.1.4.1.20044.44.2.2.2.24.1.4Columnpm124feAlmClientTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_…
1.3.6.1.4.1.20044.44.2.2.2.24.1.5Columnpm124feAlmClientTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_T…
1.3.6.1.4.1.20044.44.2.2.2.24.1.6Columnpm124feAlmClientVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_V…
1.3.6.1.4.1.20044.44.2.2.2.24.1.7Columnpm124feAlmClientVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT…
1.3.6.1.4.1.20044.44.2.2.2.24.1.8Columnpm124feAlmClientTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_LOW_A…
1.3.6.1.4.1.20044.44.2.2.2.24.1.9Columnpm124feAlmClientTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_HIG…
1.3.6.1.4.1.20044.44.2.2.2.24.1.16Columnpm124feAlmClientRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_PWR…
1.3.6.1.4.1.20044.44.2.2.2.24.1.17Columnpm124feAlmClientRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_P…
1.3.6.1.4.1.20044.44.2.2.3Nodepm124feAlmClientCrit
1.3.6.1.4.1.20044.44.2.2.3.8Tablepm124feAlmsynthAlmPortTablenot-accessiblecurrentList of pm124feAlmsynthAlmPort Article
1.3.6.1.4.1.20044.44.2.2.3.8.1Rowpm124feAlmsynthAlmPortEntrynot-accessiblecurrentRow definition for the pm124feAlmsynthAlmPort table
1.3.6.1.4.1.20044.44.2.2.3.8.1.1Columnpm124feAlmsynthAlmPortIndexread-onlycurrentIndex definition for the pm124feAlmsynthAlmPort table
1.3.6.1.4.1.20044.44.2.2.3.8.1.2Columnpm124feAlmClientSfpAbsentPortnread-onlycurrentClient SFP not plugged :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is pres…
1.3.6.1.4.1.20044.44.2.2.3.8.1.3Columnpm124feAlmClientDdmAbsentPortnread-onlycurrentDDM supported on client SFP :This OID indicates that the Client SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.44.2.2.3.8.1.5Columnpm124feAlmClientHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL_ACC_1 <Probcause> <Alarmtype> <Polar…
1.3.6.1.4.1.20044.44.2.2.3.8.1.6Columnpm124feAlmClientLsdPortnread-onlycurrentClient SFP optical TX ON :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the client transceiver laser is O…
1.3.6.1.4.1.20044.44.2.2.3.8.1.7Columnpm124feAlmClientLocalOosPortnread-onlycurrentLocal Client port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.44.2.2.3.8.1.8Columnpm124feAlmClientRemoteOosPortnread-onlycurrentRemote Client port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.44.2.2.3.8.1.9Columnpm124feAlmClientDwCaisPortnread-onlycurrentClient AIS inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.44.2.2.3.8.1.10Columnpm124feAlmClientSfpDdmWarningPortnread-onlycurrentWarning on Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.44.2.2.3.8.1.11Columnpm124feAlmClientSfpDdmAlmPortnread-onlycurrentAlarm on Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.44.2.2.3.8.1.13Columnpm124feAlmClientFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL_ACC_1 <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.44.2.2.3.8.1.17Columnpm124feAlmClientUpCsfPortnread-onlycurrentClient Signal Fail inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.44.2.2.3.16Tablepm124feAlmclientAccessioAlmTablenot-accessiblecurrentList of pm124feAlmclientAccessioAlm Article
1.3.6.1.4.1.20044.44.2.2.3.16.1Rowpm124feAlmclientAccessioAlmEntrynot-accessiblecurrentRow definition for the pm124feAlmclientAccessioAlm table
1.3.6.1.4.1.20044.44.2.2.3.16.1.1Columnpm124feAlmclientAccessioAlmIndexread-onlycurrentIndex definition for the pm124feAlmclientAccessioAlm table
1.3.6.1.4.1.20044.44.2.2.3.16.1.2Columnpm124feAlmClientLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.44.2.2.3.16.1.5Columnpm124feAlmClientLosPortnread-onlycurrentLoss of Optical signal on Client :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.44.2.2.3.40Tablepm124feAlmclientAccAlmTablenot-accessiblecurrentList of pm124feAlmclientAccAlm Article
1.3.6.1.4.1.20044.44.2.2.3.40.1Rowpm124feAlmclientAccAlmEntrynot-accessiblecurrentRow definition for the pm124feAlmclientAccAlm table
1.3.6.1.4.1.20044.44.2.2.3.40.1.1Columnpm124feAlmclientAccAlmIndexread-onlycurrentIndex definition for the pm124feAlmclientAccAlm table
1.3.6.1.4.1.20044.44.2.2.3.40.1.2Columnpm124feAlmClientOosPortnread-onlycurrentClient Loss of synchro :This OID indicates the upstream client input port has lost synchronization on its decoder <Help> This alarms indicates if the input cli…
1.3.6.1.4.1.20044.44.2.2.3.40.1.11Columnpm124feAlmClientUpEsOvlPortnread-onlycurrentClient Upstream buffer overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.44.2.2.3.40.1.12Columnpm124feAlmClientCsfDetPortnread-onlycurrentClient Signal Fail detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.44.2.2.3.40.1.15Columnpm124feAlmClientDwEsOvlPortnread-onlycurrentClient Downstream buffer overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.44.2.3Nodepm124feAlmLine
1.3.6.1.4.1.20044.44.2.3.1Nodepm124feAlmLineNurg
1.3.6.1.4.1.20044.44.2.3.1.66Tablepm124feAlmlineSfpWarnDdmTablenot-accessiblecurrentList of pm124feAlmlineSfpWarnDdm Article
1.3.6.1.4.1.20044.44.2.3.1.66.1Rowpm124feAlmlineSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm124feAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.44.2.3.1.66.1.1Columnpm124feAlmlineSfpWarnDdmIndexread-onlycurrentIndex definition for the pm124feAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.44.2.3.1.66.1.2Columnpm124feAlmLineTxPwLowWngPortnread-onlycurrentLine SFP Tx Power Low warning :Warning indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE…
1.3.6.1.4.1.20044.44.2.3.1.66.1.3Columnpm124feAlmLineTxPwrHighWngPortnread-onlycurrentLine SFP Tx Power High warning :Warning indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.44.2.3.1.66.1.4Columnpm124feAlmLineTxBiasLowWngPortnread-onlycurrentLine SFP Bias Low warning :Warning indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.44.2.3.1.66.1.5Columnpm124feAlmLineTxBiasHighWngPortnread-onlycurrentLine SFP Bias High warning :Warning indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.44.2.3.1.66.1.6Columnpm124feAlmLineVccLowWngPortnread-onlycurrentLine SFP Power Supply Low warning :Warning indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.44.2.3.1.66.1.7Columnpm124feAlmLineVccHighWngPortnread-onlycurrentLine SFP Power Supply High warning :Warning indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.44.2.3.1.66.1.8Columnpm124feAlmLineTempLowWngPortnread-onlycurrentLine SFP Temp Low warning :Warning indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP…
1.3.6.1.4.1.20044.44.2.3.1.66.1.9Columnpm124feAlmLineTempHighWngPortnread-onlycurrentLine SFP Temp High warning :Warning indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TE…
1.3.6.1.4.1.20044.44.2.3.1.66.1.16Columnpm124feAlmLineRxPwrLowWngPortnread-onlycurrentLine SFP Rx Power Low warning :Warning indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_…
1.3.6.1.4.1.20044.44.2.3.1.66.1.17Columnpm124feAlmLineRxPwrHighWngPortnread-onlycurrentLine SFP Rx Power High warning :Warning indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.44.2.3.2Nodepm124feAlmLineUrg
1.3.6.1.4.1.20044.44.2.3.2.65Tablepm124feAlmlineSfpAlmDdmTablenot-accessiblecurrentList of pm124feAlmlineSfpAlmDdm Article
1.3.6.1.4.1.20044.44.2.3.2.65.1Rowpm124feAlmlineSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm124feAlmlineSfpAlmDdm table
1.3.6.1.4.1.20044.44.2.3.2.65.1.1Columnpm124feAlmlineSfpAlmDdmIndexread-onlycurrentIndex definition for the pm124feAlmlineSfpAlmDdm table
1.3.6.1.4.1.20044.44.2.3.2.65.1.2Columnpm124feAlmLineTxPwrLowAlaPortnread-onlycurrentLine SFP Tx Power Low :Alarm indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_LO…
1.3.6.1.4.1.20044.44.2.3.2.65.1.3Columnpm124feAlmLineTxPwrHighAlaPortnread-onlycurrentLine SFP Tx Power High :Alarm indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_…
1.3.6.1.4.1.20044.44.2.3.2.65.1.4Columnpm124feAlmLineTxBiasLowAlaPortnread-onlycurrentLine SFP Bias Low :Alarm indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BIAS…
1.3.6.1.4.1.20044.44.2.3.2.65.1.5Columnpm124feAlmLineTxBiasHighAlaPortnread-onlycurrentLine SFP Bias High :Alarm indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BI…
1.3.6.1.4.1.20044.44.2.3.2.65.1.6Columnpm124feAlmLineVccLowAlaPortnread-onlycurrentLine SFP Power Supply Low :Alarm indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC_L…
1.3.6.1.4.1.20044.44.2.3.2.65.1.7Columnpm124feAlmLineVccHighAlaPortnread-onlycurrentLine SFP Power Supply High :Alarm indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC…
1.3.6.1.4.1.20044.44.2.3.2.65.1.8Columnpm124feAlmLineTempLowAlaPortnread-onlycurrentLine SFP Temp Low :Alarm indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_LOW_ALA <…
1.3.6.1.4.1.20044.44.2.3.2.65.1.9Columnpm124feAlmLineTempHighAlaPortnread-onlycurrentLine SFP Temp High :Alarm indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_HIGH_AL…
1.3.6.1.4.1.20044.44.2.3.2.65.1.16Columnpm124feAlmLineRxPwrLowAlaPortnread-onlycurrentLine SFP Rx Power Low :Alarm indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_LOW…
1.3.6.1.4.1.20044.44.2.3.2.65.1.17Columnpm124feAlmLineRxPwrHighAlaPortnread-onlycurrentLine SFP Rx Power High :Alarm indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_H…
1.3.6.1.4.1.20044.44.2.3.3Nodepm124feAlmLineCrit
1.3.6.1.4.1.20044.44.2.3.3.7Tablepm124feAlmsynthAlmLineTablenot-accessiblecurrentList of pm124feAlmsynthAlmLine Article
1.3.6.1.4.1.20044.44.2.3.3.7.1Rowpm124feAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm124feAlmsynthAlmLine table
1.3.6.1.4.1.20044.44.2.3.3.7.1.1Columnpm124feAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm124feAlmsynthAlmLine table
1.3.6.1.4.1.20044.44.2.3.3.7.1.2Columnpm124feAlmLineSfpAbsentPortnread-onlycurrentLine SFP not plugged :This OID indicates that the SFP module is not present in the line port. <Help> This alarm indicates if the line transceiver is present. <…
1.3.6.1.4.1.20044.44.2.3.3.7.1.3Columnpm124feAlmLineDdmAbsentPortnread-onlycurrentDDM supported on Line SFP :This OID indicates that the SFP module on line port does not support Digital Diagnostic Monitoring Functions <Help> This status indi…
1.3.6.1.4.1.20044.44.2.3.3.7.1.5Columnpm124feAlmLineHwFailPortnread-onlycurrentLine HW Fail :This OID indicates a failure condition on the Line port, the most probable cause being a HW issue <Condtype> LINE_HW_FAIL <Probcause> <Alarmtype>…
1.3.6.1.4.1.20044.44.2.3.3.7.1.6Columnpm124feAlmLineLsdPortnread-onlycurrentLine SFP optical TX ON :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the line transceiver laser is ON or…
1.3.6.1.4.1.20044.44.2.3.3.7.1.7Columnpm124feAlmLineLocalOosPortnread-onlycurrentLine port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.44.2.3.3.7.1.10Columnpm124feAlmLineDdmWarningPortnread-onlycurrentWarning on Line SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detected …
1.3.6.1.4.1.20044.44.2.3.3.7.1.11Columnpm124feAlmLineDdmAlmPortnread-onlycurrentAlarm on Line SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on th…
1.3.6.1.4.1.20044.44.2.3.3.7.1.13Columnpm124feAlmLineFailPortnread-onlycurrentLine Fail :This OID indicates a failure on the Client port <Condtype> LINE_FAIL <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.44.2.3.3.64Tablepm124feAlmlineAccessioAlmTablenot-accessiblecurrentList of pm124feAlmlineAccessioAlm Article
1.3.6.1.4.1.20044.44.2.3.3.64.1Rowpm124feAlmlineAccessioAlmEntrynot-accessiblecurrentRow definition for the pm124feAlmlineAccessioAlm table
1.3.6.1.4.1.20044.44.2.3.3.64.1.1Columnpm124feAlmlineAccessioAlmIndexread-onlycurrentIndex definition for the pm124feAlmlineAccessioAlm table
1.3.6.1.4.1.20044.44.2.3.3.64.1.2Columnpm124feAlmLineLasFailPortnread-onlycurrentLine SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the line port (this alarm reports the transmitter failure alarm gene…
1.3.6.1.4.1.20044.44.2.3.3.64.1.5Columnpm124feAlmLineLosPortnread-onlycurrentLoss of Optical signal on Line :This OID indicates that no signal is present on the SFP of the line port <Help> This alarm indicates if an optical signal is de…
1.3.6.1.4.1.20044.44.2.3.3.64.1.7Columnpm124feAlmLineLossSyncPortnread-onlycurrentLine Loss of 10b/8b Sync :This OID indicates the upstream line input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if the in…
1.3.6.1.4.1.20044.44.3Nodepm124femeasures
1.3.6.1.4.1.20044.44.3.1Nodepm124feMesrOther
1.3.6.1.4.1.20044.44.3.2Nodepm124feMesrClient
1.3.6.1.4.1.20044.44.3.2.16Tablepm124feMesrclientTemperatureTablenot-accessiblecurrentList of pm124feMesrclientTemperature Article
1.3.6.1.4.1.20044.44.3.2.16.1Rowpm124feMesrclientTemperatureEntrynot-accessiblecurrentRow definition for the pm124feMesrclientTemperature table
1.3.6.1.4.1.20044.44.3.2.16.1.1Columnpm124feMesrclientTemperatureIndexread-onlycurrentIndex definition for the pm124feMesrclientTemperature table
1.3.6.1.4.1.20044.44.3.2.16.1.2Columnpm124feMesrclientTemperaturePortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit …
1.3.6.1.4.1.20044.44.3.2.24Tablepm124feMesrclientVoltTablenot-accessiblecurrentList of pm124feMesrclientVolt Article
1.3.6.1.4.1.20044.44.3.2.24.1Rowpm124feMesrclientVoltEntrynot-accessiblecurrentRow definition for the pm124feMesrclientVolt table
1.3.6.1.4.1.20044.44.3.2.24.1.1Columnpm124feMesrclientVoltIndexread-onlycurrentIndex definition for the pm124feMesrclientVolt table
1.3.6.1.4.1.20044.44.3.2.24.1.2Columnpm124feMesrclientVoltPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the SFP plugged into port, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/100…
1.3.6.1.4.1.20044.44.3.2.32Tablepm124feMesrclientTxBiasTablenot-accessiblecurrentList of pm124feMesrclientTxBias Article
1.3.6.1.4.1.20044.44.3.2.32.1Rowpm124feMesrclientTxBiasEntrynot-accessiblecurrentRow definition for the pm124feMesrclientTxBias table
1.3.6.1.4.1.20044.44.3.2.32.1.1Columnpm124feMesrclientTxBiasIndexread-onlycurrentIndex definition for the pm124feMesrclientTxBias table
1.3.6.1.4.1.20044.44.3.2.32.1.2Columnpm124feMesrclientTxBiasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> Th…
1.3.6.1.4.1.20044.44.3.2.40Tablepm124feMesrclientTxPowerTablenot-accessiblecurrentList of pm124feMesrclientTxPower Article
1.3.6.1.4.1.20044.44.3.2.40.1Rowpm124feMesrclientTxPowerEntrynot-accessiblecurrentRow definition for the pm124feMesrclientTxPower table
1.3.6.1.4.1.20044.44.3.2.40.1.1Columnpm124feMesrclientTxPowerIndexread-onlycurrentIndex definition for the pm124feMesrclientTxPower table
1.3.6.1.4.1.20044.44.3.2.40.1.2Columnpm124feMesrclientTxPowerPortnread-onlycurrentClient SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-…
1.3.6.1.4.1.20044.44.3.2.48Tablepm124feMesrclientRxPowerTablenot-accessiblecurrentList of pm124feMesrclientRxPower Article
1.3.6.1.4.1.20044.44.3.2.48.1Rowpm124feMesrclientRxPowerEntrynot-accessiblecurrentRow definition for the pm124feMesrclientRxPower table
1.3.6.1.4.1.20044.44.3.2.48.1.1Columnpm124feMesrclientRxPowerIndexread-onlycurrentIndex definition for the pm124feMesrclientRxPower table
1.3.6.1.4.1.20044.44.3.2.48.1.2Columnpm124feMesrclientRxPowerPortnread-onlycurrentClient SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (U…
1.3.6.1.4.1.20044.44.3.3Nodepm124feMesrLine
1.3.6.1.4.1.20044.44.3.3.64Tablepm124feMesrlineTemperatureTablenot-accessiblecurrentList of pm124feMesrlineTemperature Article
1.3.6.1.4.1.20044.44.3.3.64.1Rowpm124feMesrlineTemperatureEntrynot-accessiblecurrentRow definition for the pm124feMesrlineTemperature table
1.3.6.1.4.1.20044.44.3.3.64.1.1Columnpm124feMesrlineTemperatureIndexread-onlycurrentIndex definition for the pm124feMesrlineTemperature table
1.3.6.1.4.1.20044.44.3.3.64.1.2Columnpm124feMesrlineTemperaturePortnread-onlycurrentLine SFP Temperature :This OID gives the temperature value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C)…
1.3.6.1.4.1.20044.44.3.3.65Tablepm124feMesrlineVoltTablenot-accessiblecurrentList of pm124feMesrlineVolt Article
1.3.6.1.4.1.20044.44.3.3.65.1Rowpm124feMesrlineVoltEntrynot-accessiblecurrentRow definition for the pm124feMesrlineVolt table
1.3.6.1.4.1.20044.44.3.3.65.1.1Columnpm124feMesrlineVoltIndexread-onlycurrentIndex definition for the pm124feMesrlineVolt table
1.3.6.1.4.1.20044.44.3.3.65.1.2Columnpm124feMesrlineVoltPortnread-onlycurrentLine SFP Power Supply :This OID gives the 3V3 voltage value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) …
1.3.6.1.4.1.20044.44.3.3.66Tablepm124feMesrlineTxBiasTablenot-accessiblecurrentList of pm124feMesrlineTxBias Article
1.3.6.1.4.1.20044.44.3.3.66.1Rowpm124feMesrlineTxBiasEntrynot-accessiblecurrentRow definition for the pm124feMesrlineTxBias table
1.3.6.1.4.1.20044.44.3.3.66.1.1Columnpm124feMesrlineTxBiasIndexread-onlycurrentIndex definition for the pm124feMesrlineTxBias table
1.3.6.1.4.1.20044.44.3.3.66.1.2Columnpm124feMesrlineTxBiasPortnread-onlycurrentLine SFP Laser Bias :This OID gives the bias value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This m…
1.3.6.1.4.1.20044.44.3.3.67Tablepm124feMesrlineTxPowerTablenot-accessiblecurrentList of pm124feMesrlineTxPower Article
1.3.6.1.4.1.20044.44.3.3.67.1Rowpm124feMesrlineTxPowerEntrynot-accessiblecurrentRow definition for the pm124feMesrlineTxPower table
1.3.6.1.4.1.20044.44.3.3.67.1.1Columnpm124feMesrlineTxPowerIndexread-onlycurrentIndex definition for the pm124feMesrlineTxPower table
1.3.6.1.4.1.20044.44.3.3.67.1.2Columnpm124feMesrlineTxPowerPortnread-onlycurrentLine SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) …
1.3.6.1.4.1.20044.44.3.3.68Tablepm124feMesrlineRxPowerTablenot-accessiblecurrentList of pm124feMesrlineRxPower Article
1.3.6.1.4.1.20044.44.3.3.68.1Rowpm124feMesrlineRxPowerEntrynot-accessiblecurrentRow definition for the pm124feMesrlineRxPower table
1.3.6.1.4.1.20044.44.3.3.68.1.1Columnpm124feMesrlineRxPowerIndexread-onlycurrentIndex definition for the pm124feMesrlineRxPower table
1.3.6.1.4.1.20044.44.3.3.68.1.2Columnpm124feMesrlineRxPowerPortnread-onlycurrentLine SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit …
1.3.6.1.4.1.20044.44.4Nodepm124fecounters
1.3.6.1.4.1.20044.44.4.1Nodepm124feCntOther
1.3.6.1.4.1.20044.44.4.2Nodepm124feCntClient
1.3.6.1.4.1.20044.44.4.2.16Tablepm124feCntclientCbipErrCntTablenot-accessiblecurrentList of pm124feCntclientCbipErrCnt Article
1.3.6.1.4.1.20044.44.4.2.16.1Rowpm124feCntclientCbipErrCntEntrynot-accessiblecurrentRow definition for the pm124feCntclientCbipErrCnt table
1.3.6.1.4.1.20044.44.4.2.16.1.1Columnpm124feCntclientCbipErrCntIndexread-onlycurrentIndex definition for the pm124feCntclientCbipErrCnt table
1.3.6.1.4.1.20044.44.4.2.16.1.2Columnpm124feCntclientCbipErrCntValuePortnread-onlycurrentClient CBIP errors (Err Sec) :This counter is incremented by one each time one or several CBIP parity error is detected during one second on the client output …
1.3.6.1.4.1.20044.44.4.2.16.1.3Columnpm124feCntclientCbipErrCntErrorPortnread-onlycurrentClient CBIP counter error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.44.4.2.16.1.4Columnpm124feCntclientCbipErrCntOverloadPortnread-onlycurrentClient CBIP counter overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.44.4.2.24Tablepm124feCntclientFcsErrCntTablenot-accessiblecurrentList of pm124feCntclientFcsErrCnt Article
1.3.6.1.4.1.20044.44.4.2.24.1Rowpm124feCntclientFcsErrCntEntrynot-accessiblecurrentRow definition for the pm124feCntclientFcsErrCnt table
1.3.6.1.4.1.20044.44.4.2.24.1.1Columnpm124feCntclientFcsErrCntIndexread-onlycurrentIndex definition for the pm124feCntclientFcsErrCnt table
1.3.6.1.4.1.20044.44.4.2.24.1.2Columnpm124feCntclientFcsErrCntValuePortnread-onlycurrentClient FCS errors (Err Sec) :This counter is incremented by one each time one or several FCS error is detected during one second on the client input stream. <H…
1.3.6.1.4.1.20044.44.4.2.24.1.3Columnpm124feCntclientFcsErrCntErrorPortnread-onlycurrentClient B1 counter error :This OID when set indicates the B1 counter value is invalid on Port
1.3.6.1.4.1.20044.44.4.2.24.1.4Columnpm124feCntclientFcsErrCntOverloadPortnread-onlycurrentClient B1 counter overload :This OID when set indicates a B1 counter overload on Port
1.3.6.1.4.1.20044.44.4.3Nodepm124feCntLine
1.3.6.1.4.1.20044.44.4.3.64Tablepm124feCntlineDispErrCntTablenot-accessiblecurrentList of pm124feCntlineDispErrCnt Article
1.3.6.1.4.1.20044.44.4.3.64.1Rowpm124feCntlineDispErrCntEntrynot-accessiblecurrentRow definition for the pm124feCntlineDispErrCnt table
1.3.6.1.4.1.20044.44.4.3.64.1.1Columnpm124feCntlineDispErrCntIndexread-onlycurrentIndex definition for the pm124feCntlineDispErrCnt table
1.3.6.1.4.1.20044.44.4.3.64.1.2Columnpm124feCntlineDispErrCntValuePortnread-onlycurrentLine RD errors (Err Sec) :This counter is in incremented by one each time one or several 10b/8b running disparity error is detected during one second on the Li…
1.3.6.1.4.1.20044.44.4.3.64.1.3Columnpm124feCntlineDispErrCntErrorPortnread-onlycurrentLine counter error :This OID when set indicates the line error counter value is invalid on Line
1.3.6.1.4.1.20044.44.4.3.64.1.4Columnpm124feCntlineDispErrCntOverloadPortnread-onlycurrentLine counter overload :This OID when set indicates a line input error counter overload on Line
1.3.6.1.4.1.20044.44.4.3.65Tablepm124feCntlineCrcErrCntTablenot-accessiblecurrentList of pm124feCntlineCrcErrCnt Article
1.3.6.1.4.1.20044.44.4.3.65.1Rowpm124feCntlineCrcErrCntEntrynot-accessiblecurrentRow definition for the pm124feCntlineCrcErrCnt table
1.3.6.1.4.1.20044.44.4.3.65.1.1Columnpm124feCntlineCrcErrCntIndexread-onlycurrentIndex definition for the pm124feCntlineCrcErrCnt table
1.3.6.1.4.1.20044.44.4.3.65.1.2Columnpm124feCntlineCrcErrCntValuePortnread-onlycurrentLine CRC errors (Err Sec) :This counter is incremented by one each time one or several CRC error is detected during one second on the Line port <Help> This cou…
1.3.6.1.4.1.20044.44.4.3.65.1.3Columnpm124feCntlineCrcErrCntErrorPortnread-onlycurrentCRC Errors counter error :This OID when set indicates the CRC Errors counter value is invalid on line port
1.3.6.1.4.1.20044.44.4.3.65.1.4Columnpm124feCntlineCrcErrCntOverloadPortnread-onlycurrentCRC Errors counter overload :This OID when set indicates a CRC Errors counter overload on line port
1.3.6.1.4.1.20044.44.4.259Scalarpm124feCntCountersResetread-writecurrentCounters Reset:This OID resets and restarts all the counters
1.3.6.1.4.1.20044.44.4.260Scalarpm124feCntCountersStopread-writecurrentCounters stop:This OID stops all the counters
1.3.6.1.4.1.20044.44.6Nodepm124fecontrolsWrite
1.3.6.1.4.1.20044.44.6.1Nodepm124feCtrlOther
1.3.6.1.4.1.20044.44.6.1.0Nodepm124feCtrlsynth0
1.3.6.1.4.1.20044.44.6.1.0.1Scalarpm124feCtrlConfLoadread-writecurrentLoad Configuration Tables :When set this enables loading from flash configuration1 into the module.
1.3.6.1.4.1.20044.44.6.1.0.9Scalarpm124feCtrlConfFlashread-writecurrentWrite Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. <Help> This control saves the customer config…
1.3.6.1.4.1.20044.44.6.1.0.13Scalarpm124feCtrlConfClearread-writecurrentClear Configuration Tables :This bit clears the configuration tables from configuration in the flash. <Help> This control restores the default configuration of…
1.3.6.1.4.1.20044.44.6.1.4Nodepm124feCtrlsynth4
1.3.6.1.4.1.20044.44.6.1.4.1Scalarpm124feCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.44.6.1.4.2Scalarpm124feCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.44.6.1.5Nodepm124feCtrlswMgnt
1.3.6.1.4.1.20044.44.6.1.5.2Scalarpm124feCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start…
1.3.6.1.4.1.20044.44.6.1.5.3Scalarpm124feCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unch…
1.3.6.1.4.1.20044.44.6.1.72Nodepm124feCtrlledTest
1.3.6.1.4.1.20044.44.6.1.72.1Scalarpm124feCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.44.6.1.72.2Scalarpm124feCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.44.6.1.72.3Scalarpm124feCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.44.6.1.73Nodepm124feCtrlmoduleOosMode
1.3.6.1.4.1.20044.44.6.1.73.1Scalarpm124feCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.44.6.2Nodepm124feCtrlClient
1.3.6.1.4.1.20044.44.6.2.16Tablepm124feCtrlclientSfpOnoffTablenot-accessiblecurrentList of pm124feCtrlclientSfpOnoff Article
1.3.6.1.4.1.20044.44.6.2.16.1Rowpm124feCtrlclientSfpOnoffEntrynot-accessiblecurrentRow definition for the pm124feCtrlclientSfpOnoff table
1.3.6.1.4.1.20044.44.6.2.16.1.1Columnpm124feCtrlclientSfpOnoffIndexread-onlycurrentIndex definition for the pm124feCtrlclientSfpOnoff table
1.3.6.1.4.1.20044.44.6.2.16.1.2Columnpm124feCtrlclientSfpOnoffPortnread-writecurrentSFP OFF (100 Base Sx only) :This OID switches off the clients SFP <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.44.6.2.17Tablepm124feCtrlclientLoopTablenot-accessiblecurrentList of pm124feCtrlclientLoop Article
1.3.6.1.4.1.20044.44.6.2.17.1Rowpm124feCtrlclientLoopEntrynot-accessiblecurrentRow definition for the pm124feCtrlclientLoop table
1.3.6.1.4.1.20044.44.6.2.17.1.1Columnpm124feCtrlclientLoopIndexread-onlycurrentIndex definition for the pm124feCtrlclientLoop table
1.3.6.1.4.1.20044.44.6.2.17.1.2Columnpm124feCtrlclientLoopPortnread-writecurrentClient Access Loop Back :This OID operates an access loopback on the Client port. <Help> This control defines the access loop back of the client port
1.3.6.1.4.1.20044.44.6.2.18Tablepm124feCtrlclientCsfUpInsertTablenot-accessiblecurrentList of pm124feCtrlclientCsfUpInsert Article
1.3.6.1.4.1.20044.44.6.2.18.1Rowpm124feCtrlclientCsfUpInsertEntrynot-accessiblecurrentRow definition for the pm124feCtrlclientCsfUpInsert table
1.3.6.1.4.1.20044.44.6.2.18.1.1Columnpm124feCtrlclientCsfUpInsertIndexread-onlycurrentIndex definition for the pm124feCtrlclientCsfUpInsert table
1.3.6.1.4.1.20044.44.6.2.18.1.2Columnpm124feCtrlclientCsfUpInsertPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port.
1.3.6.1.4.1.20044.44.6.2.19Tablepm124feCtrlclientCaisDwInsertTablenot-accessiblecurrentList of pm124feCtrlclientCaisDwInsert Article
1.3.6.1.4.1.20044.44.6.2.19.1Rowpm124feCtrlclientCaisDwInsertEntrynot-accessiblecurrentRow definition for the pm124feCtrlclientCaisDwInsert table
1.3.6.1.4.1.20044.44.6.2.19.1.1Columnpm124feCtrlclientCaisDwInsertIndexread-onlycurrentIndex definition for the pm124feCtrlclientCaisDwInsert table
1.3.6.1.4.1.20044.44.6.2.19.1.2Columnpm124feCtrlclientCaisDwInsertPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port.
1.3.6.1.4.1.20044.44.6.2.20Tablepm124feCtrlclientOosModeTablenot-accessiblecurrentList of pm124feCtrlclientOosMode Article
1.3.6.1.4.1.20044.44.6.2.20.1Rowpm124feCtrlclientOosModeEntrynot-accessiblecurrentRow definition for the pm124feCtrlclientOosMode table
1.3.6.1.4.1.20044.44.6.2.20.1.1Columnpm124feCtrlclientOosModeIndexread-onlycurrentIndex definition for the pm124feCtrlclientOosMode table
1.3.6.1.4.1.20044.44.6.2.20.1.2Columnpm124feCtrlclientOosModePortnread-writecurrentClient port Out of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.44.6.3Nodepm124feCtrlLine
1.3.6.1.4.1.20044.44.6.3.64Tablepm124feCtrllineSfpOnoffTablenot-accessiblecurrentList of pm124feCtrllineSfpOnoff Article
1.3.6.1.4.1.20044.44.6.3.64.1Rowpm124feCtrllineSfpOnoffEntrynot-accessiblecurrentRow definition for the pm124feCtrllineSfpOnoff table
1.3.6.1.4.1.20044.44.6.3.64.1.1Columnpm124feCtrllineSfpOnoffIndexread-onlycurrentIndex definition for the pm124feCtrllineSfpOnoff table
1.3.6.1.4.1.20044.44.6.3.64.1.2Columnpm124feCtrllineSfpOnoffPortnread-writecurrentLine SFP Optical Output Shut Down :This OID switches off the line SFP <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.44.6.3.65Tablepm124feCtrllineOosModeTablenot-accessiblecurrentList of pm124feCtrllineOosMode Article
1.3.6.1.4.1.20044.44.6.3.65.1Rowpm124feCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm124feCtrllineOosMode table
1.3.6.1.4.1.20044.44.6.3.65.1.1Columnpm124feCtrllineOosModeIndexread-onlycurrentIndex definition for the pm124feCtrllineOosMode table
1.3.6.1.4.1.20044.44.6.3.65.1.2Columnpm124feCtrllineOosModePortnread-writecurrentLine port Out of Service :This OID sets the line port Out Of Service <Help> This controls defines the service state of the line port
1.3.6.1.4.1.20044.44.6.3.66Tablepm124feCtrllineLoopTablenot-accessiblecurrentList of pm124feCtrllineLoop Article
1.3.6.1.4.1.20044.44.6.3.66.1Rowpm124feCtrllineLoopEntrynot-accessiblecurrentRow definition for the pm124feCtrllineLoop table
1.3.6.1.4.1.20044.44.6.3.66.1.1Columnpm124feCtrllineLoopIndexread-onlycurrentIndex definition for the pm124feCtrllineLoop table
1.3.6.1.4.1.20044.44.6.3.66.1.2Columnpm124feCtrllineLoopPortnread-writecurrentLine Access Loop Back :This OID operates an access loopback on the line port. <Help> This control defines the access loop back of the line port
1.3.6.1.4.1.20044.44.7Nodepm124feri
1.3.6.1.4.1.20044.44.7.1Nodepm124feriTable
1.3.6.1.4.1.20044.44.7.1.1Tablepm124feRinvClientTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.44.7.1.1.1Rowpm124feRinvClientEntrynot-accessiblecurrentRow definition for the Client SFP table
1.3.6.1.4.1.20044.44.7.1.1.1.1Columnpm124feRinvClientIndexread-onlycurrentIndex for Client SFP table
1.3.6.1.4.1.20044.44.7.1.1.1.2Columnpm124feRinvSfpClientread-onlycurrentInventory for the SFP: This OID contains the inventory for the Client SFP
1.3.6.1.4.1.20044.44.7.1.2Tablepm124feRinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.44.7.1.2.1Rowpm124feRinvLineEntrynot-accessiblecurrentRow definition for the Line SFP table
1.3.6.1.4.1.20044.44.7.1.2.1.1Columnpm124feRinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.44.7.1.2.1.2Columnpm124feRinvsfpLineread-onlycurrentInventory for the SFP: This OID contains the inventory for the Line SFP
1.3.6.1.4.1.20044.44.7.2Scalarpm124feRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.44.7.3Scalarpm124feRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.44.7.4Scalarpm124feRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.44.7.5Scalarpm124feRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.44.7.6Scalarpm124feRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.44.9Nodepm124feConfig
1.3.6.1.4.1.20044.44.9.1Nodepm124feCfgLsd
1.3.6.1.4.1.20044.44.9.1.1Tablepm124feCfgClientLsdTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.44.9.1.1.1Rowpm124feCfgClientLsdEntrynot-accessiblecurrentRow definition for the lsd table
1.3.6.1.4.1.20044.44.9.1.1.1.1Columnpm124feCfgClientLsdIndexread-onlycurrentIndex definition for the clientLsd table
1.3.6.1.4.1.20044.44.9.1.1.1.3Columnpm124feCfgClientLsdModePortnread-writecurrentCAIS mode on Client Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port
1.3.6.1.4.1.20044.44.9.1.1.1.4Columnpm124feCfgClientAccessioCtrbInsPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.44.9.1.1.1.5Columnpm124feCfgClientAccCtrbInsPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.44.9.1.1.1.6Columnpm124feCfgLineAccessioCtrbInsPortnread-writecurrentCSF contributors on Client Port :This register selects the contributors to upstream CAIS/CSF on Port
1.3.6.1.4.1.20044.44.9.1.1.1.8Columnpm124feCfgClientAccCtrbActPortnread-writecurrentCAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.44.9.1.1.1.9Columnpm124feCfgLineAccessioCtrbActPortnread-writecurrentCAIS contributors on Client Port :This register selects the contributors to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.44.9.2Nodepm124feCfgStartUp
1.3.6.1.4.1.20044.44.9.2.1Tablepm124feCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.44.9.2.1.1Rowpm124feCfgClientStartupEntrynot-accessiblecurrentRow definition for the startUp table
1.3.6.1.4.1.20044.44.9.2.1.1.1Columnpm124feCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.44.9.2.1.1.3Columnpm124feCfgClientTrscvCtrlPortnread-writecurrentDefault Settings on client TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.44.9.2.1.1.5Columnpm124feCfgClientOosModePortnread-writecurrentDefault Settings on client TRSCV :This register configures the default initialisation settings on client transceiver.
1.3.6.1.4.1.20044.44.9.2.2Nodepm124fetablelineStartup
1.3.6.1.4.1.20044.44.9.2.2.2Scalarpm124feCfglineTrscvCtrlread-writecurrentDefault Settings on line TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.44.9.2.2.3Scalarpm124feCfglineOosModeread-writecurrentDefault Settings on line TRSCV :This register configures the default initialisation settings on line transceiver.
1.3.6.1.4.1.20044.44.9.3Nodepm124feCfgLabels
1.3.6.1.4.1.20044.44.9.3.1Tablepm124feCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.44.9.3.1.1Rowpm124feCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.44.9.3.1.1.1Columnpm124feCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.44.9.3.1.1.3Columnpm124feCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.44.9.3.2Tablepm124feCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.44.9.3.2.1Rowpm124feCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.44.9.3.2.1.1Columnpm124feCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.44.9.3.2.1.3Columnpm124feCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.44.9.257Scalarpm124feCfgWriteConfigurationread-writecurrentWrite configuration to module:This OID writes the complete configuration to the module
1.3.6.1.4.1.20044.44.10Nodepm124fetraps
1.3.6.1.4.1.20044.44.10.2Scalarpm124fetrapPortNumberread-onlycurrentLast port which generates a trap
1.3.6.1.4.1.20044.44.10.3Scalarpm124fetrapLineNumberread-onlycurrentLast Line which generates a trap
1.3.6.1.4.1.20044.44.10.4Scalarpm124fetrapBoardNumberread-onlycurrentLast module which generates a trap
1.3.6.1.4.1.20044.44.10.30Notificationpm124feLineTrapNotUrgentGoesOncurrentNot urgent Line default is activated
1.3.6.1.4.1.20044.44.10.31Notificationpm124feLineTrapNotUrgentGoesOffcurrentNot urgent Line default disappeared
1.3.6.1.4.1.20044.44.10.32Notificationpm124feLineTrapUrgentGoesOncurrentUrgent Line default is activated
1.3.6.1.4.1.20044.44.10.33Notificationpm124feLineTrapUrgentGoesOffcurrentUrgent Line default disappeared
1.3.6.1.4.1.20044.44.10.34Notificationpm124feLineTrapCritGoesOncurrentCritical Line default is activated
1.3.6.1.4.1.20044.44.10.35Notificationpm124feLineTrapCritGoesOffcurrentCritical Line default disappeared
1.3.6.1.4.1.20044.44.10.40Notificationpm124feClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.44.10.41Notificationpm124feClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.44.10.42Notificationpm124feClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.44.10.43Notificationpm124feClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.44.10.44Notificationpm124feClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.44.10.45Notificationpm124feClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.44.10.50Notificationpm124fePowerTrapUrgentGoesOncurrentUrgent power supply default is activated
1.3.6.1.4.1.20044.44.10.51Notificationpm124fePowerTrapUrgentGoesOffcurrentUrgent power supply default disappeared