EKINOPS-Pm251d-MIB

444 objects
MIB for the Ekinops Pm251d hardware.
OIDNameAccessStatusDescription
1.3.6.1.4.1.20044.31IdentitymodulePm251dMIB for the Ekinops Pm251d hardware.
1.3.6.1.4.1.20044.31.2Nodepm251dalarms
1.3.6.1.4.1.20044.31.2.1Nodepm251dAlmOther
1.3.6.1.4.1.20044.31.2.1.1Nodepm251dAlmOtherNurg
1.3.6.1.4.1.20044.31.2.1.1.0Nodepm251dAlmsynthAlm0
1.3.6.1.4.1.20044.31.2.1.1.0.9Scalarpm251dAlmModGlobFailread-onlycurrentModule Failure :This OID is set on detection of a failure originating from the PM <Condtype> MOD_GLOB_FAIL <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.31.2.1.1.0.15Scalarpm251dAlmDefFuseAread-onlycurrentFuse A fail :This OID indicates that the fuse of the power input A is in fail condition <Help> Status of the Fuse A <Condtype> DEF_FUSE_A <Probcause> powerProb…
1.3.6.1.4.1.20044.31.2.1.1.0.16Scalarpm251dAlmDefFuseBread-onlycurrentFuse B Fail :This OID indicates that the fuse of the power input B is in fail condition <Help> Status of the Fuse B <Condtype> DEF_FUSE_B <Probcause> powerProb…
1.3.6.1.4.1.20044.31.2.1.1.2Nodepm251dAlmsynthAlm2
1.3.6.1.4.1.20044.31.2.1.1.2.1Scalarpm251dAlmConfTableSaveread-onlycurrentPM configuration Save :This OID is set during the saving of a new configuration table in the PM Flash memory. <Condtype> CONF_TABLE_SAVE <Probcause> <Alarmtype…
1.3.6.1.4.1.20044.31.2.1.1.2.2Scalarpm251dAlmInvUploadread-onlycurrentInventory Upload :This OID is set during the uploading of PM inventory information. <Condtype> INV_UPLOAD <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.31.2.1.1.2.3Scalarpm251dAlmConfTableLoadread-onlycurrentPM configuration Load :This OID is set during the loading of configuration tables in the PMs RAM. <Condtype> CONF_TABLE_LOAD <Probcause> <Alarmtype> <Polarity>…
1.3.6.1.4.1.20044.31.2.1.1.2.4Scalarpm251dAlmCorrelatOffread-onlycurrentNot used :This OID, when set, indicates that alarm correlation is not being performed. <Condtype> CORRELAT_OFF <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.31.2.1.1.2.5Scalarpm251dAlmMaintenanceOnread-onlycurrentMaintenance Mode :This OID indicates that the PM is in maintenance mode. <Help> This alarm indicates that the maintenance mode is enabled on the PM <Condtype> …
1.3.6.1.4.1.20044.31.2.1.2Nodepm251dAlmOtherUrg
1.3.6.1.4.1.20044.31.2.1.2.194Nodepm251dAlmmodInitFailLevel2
1.3.6.1.4.1.20044.31.2.1.2.194.1Scalarpm251dAlmLedFailread-onlycurrentLed Fail :This OID indicates that Led register has not been correctly initalized <Condtype> LED_FAIL <Probcause> softwareError (47) <Alarmtype> processingError…
1.3.6.1.4.1.20044.31.2.1.2.194.2Scalarpm251dAlmNextColdBootForcedread-onlycurrentNext Cold Boot Forced :This OID indicates that the next Reset will be forced Cold <Condtype> NEXT_COLD_BOOT_FORCED <Probcause> informationalStatus(1000) <Alarm…
1.3.6.1.4.1.20044.31.2.1.2.194.3Scalarpm251dAlmBootUndoneread-onlycurrentBoot Undone :This OID indicates that the boot has not been correctly achieved <Condtype> BOOT_UNDONE <Probcause> softwareError (47) <Alarmtype> processingError…
1.3.6.1.4.1.20044.31.2.1.2.194.4Scalarpm251dAlmResetHwInitFailread-onlycurrentReset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions <Condtype> RESET_HW_INIT_FAIL <Probcause> softwareError (…
1.3.6.1.4.1.20044.31.2.1.2.194.5Scalarpm251dAlmSwInitFailread-onlycurrentSW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions <Condtype> SW_INIT_FAIL <Probcause> softwareError (47) <Alarmty…
1.3.6.1.4.1.20044.31.2.1.2.195Nodepm251dAlmmodInitFailLevel3
1.3.6.1.4.1.20044.31.2.1.2.195.1Scalarpm251dAlmGwIdentFailread-onlycurrentGW Ident Fail :This OID indicates that GW identification has not been read <Condtype> GW_IDENT_FAIL <Probcause> softwareError (47) <Alarmtype> processingErrorA…
1.3.6.1.4.1.20044.31.2.1.2.195.2Scalarpm251dAlmObmTypeReadFailread-onlycurrentOBM Type Read Fail :This OID indicates that OBM type has not been recognized <Condtype> OBM_TYPE_READ_FAIL <Probcause> softwareError (47) <Alarmtype> processin…
1.3.6.1.4.1.20044.31.2.1.2.195.3Scalarpm251dAlmInitModuleFailread-onlycurrentInit Module Fail :This OID indicates that the Module has not been correctly initialized <Condtype> INIT_MODULE_FAIL <Probcause> softwareError (47) <Alarmtype> …
1.3.6.1.4.1.20044.31.2.1.2.195.5Scalarpm251dAlmSfp1InitFailread-onlycurrentSFP1 Init Fail :This OID indicates that the SFP has not been correctly initialized <Condtype> SFP1_INIT_FAIL <Probcause> softwareError (47) <Alarmtype> process…
1.3.6.1.4.1.20044.31.2.1.2.195.6Scalarpm251dAlmSfp2InitFailread-onlycurrentSFP2 Init Fail :This OID indicates that the SFP has not been correctly initialized <Condtype> SFP2_INIT_FAIL <Probcause> softwareError (47) <Alarmtype> process…
1.3.6.1.4.1.20044.31.2.1.2.195.7Scalarpm251dAlmLine1InitFailread-onlycurrentLine1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized <Condtype> LINE1_INIT_FAIL <Probcause> softwareError (47)…
1.3.6.1.4.1.20044.31.2.1.2.195.8Scalarpm251dAlmLine2InitFailread-onlycurrentLine2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized <Condtype> LINE2_INIT_FAIL <Probcause> softwareError (47) …
1.3.6.1.4.1.20044.31.2.1.2.195.9Scalarpm251dAlmClient1InitFailread-onlycurrentClient1 Init Fail :This OID indicates that Client 1 registers subset has not been correctly initialized <Condtype> CLIENT1_INIT_FAIL <Probcause> softwareError …
1.3.6.1.4.1.20044.31.2.1.2.195.10Scalarpm251dAlmClient2InitFailread-onlycurrentClient2 Init Fail :This OID indicates that Client 2 registers subset has not been correctly initialized <Condtype> CLIENT2_INIT_FAIL <Probcause> softwareError …
1.3.6.1.4.1.20044.31.2.1.3Nodepm251dAlmOtherCrit
1.3.6.1.4.1.20044.31.2.2Nodepm251dAlmPort
1.3.6.1.4.1.20044.31.2.2.1Nodepm251dAlmPortNurg
1.3.6.1.4.1.20044.31.2.2.1.48Tablepm251dAlmclientSfpWarnDdmTablenot-accessiblecurrentList of pm251dAlmclientSfpWarnDdm Article
1.3.6.1.4.1.20044.31.2.2.1.48.1Rowpm251dAlmclientSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm251dAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.31.2.2.1.48.1.1Columnpm251dAlmclientSfpWarnDdmIndexread-onlycurrentIndex definition for the pm251dAlmclientSfpWarnDdm table
1.3.6.1.4.1.20044.31.2.2.1.48.1.2Columnpm251dAlmClientTxPwLowWngPortnread-onlycurrentClient SFP Tx Power Low warning :Warning indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CL…
1.3.6.1.4.1.20044.31.2.2.1.48.1.3Columnpm251dAlmClientTxPwrHighWngPortnread-onlycurrentClient SFP Tx Power High warning :Warning indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.31.2.2.1.48.1.4Columnpm251dAlmClientTxBiasLowWngPortnread-onlycurrentClient SFP Bias Low warning :Warning indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.31.2.2.1.48.1.5Columnpm251dAlmClientTxBiasHighWngPortnread-onlycurrentClient SFP Bias High warning :Warning indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.31.2.2.1.48.1.6Columnpm251dAlmClientVccLowWngPortnread-onlycurrentClient SFP Power Supply Low warning :Warning indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.31.2.2.1.48.1.7Columnpm251dAlmClientVccHighWngPortnread-onlycurrentClient SFP Power Supply High warning :Warning indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condty…
1.3.6.1.4.1.20044.31.2.2.1.48.1.8Columnpm251dAlmClientTempLowWngPortnread-onlycurrentClient SFP Temp Low warning :Warning indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_…
1.3.6.1.4.1.20044.31.2.2.1.48.1.9Columnpm251dAlmClientTempHighWngPortnread-onlycurrentClient SFP Temp High warning :Warning indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIEN…
1.3.6.1.4.1.20044.31.2.2.1.48.1.16Columnpm251dAlmClientRxPwrLowWngPortnread-onlycurrentClient SFP Rx Power Low warning :Warning indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLI…
1.3.6.1.4.1.20044.31.2.2.1.48.1.17Columnpm251dAlmClientRxPwrHighWngPortnread-onlycurrentClient SFP Rx Power High warning :Warning indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> C…
1.3.6.1.4.1.20044.31.2.2.2Nodepm251dAlmPortUrg
1.3.6.1.4.1.20044.31.2.2.2.32Tablepm251dAlmclientSfpAlmDdmTablenot-accessiblecurrentList of pm251dAlmclientSfpAlmDdm Article
1.3.6.1.4.1.20044.31.2.2.2.32.1Rowpm251dAlmclientSfpAlmDdmEntrynot-accessiblecurrentRow definition for the pm251dAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.31.2.2.2.32.1.1Columnpm251dAlmclientSfpAlmDdmIndexread-onlycurrentIndex definition for the pm251dAlmclientSfpAlmDdm table
1.3.6.1.4.1.20044.31.2.2.2.32.1.2Columnpm251dAlmClientTxPwrLowAlaPortnread-onlycurrentClient SFP Tx Power Low :Alarm indicating that the SFP output power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_PW…
1.3.6.1.4.1.20044.31.2.2.2.32.1.3Columnpm251dAlmClientTxPwrHighAlaPortnread-onlycurrentClient SFP Tx Power High :Alarm indicating that the SFP output power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_…
1.3.6.1.4.1.20044.31.2.2.2.32.1.4Columnpm251dAlmClientTxBiasLowAlaPortnread-onlycurrentClient SFP Bias Low :Alarm indicating that the SFP laser bias current of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TX_…
1.3.6.1.4.1.20044.31.2.2.2.32.1.5Columnpm251dAlmClientTxBiasHighAlaPortnread-onlycurrentClient SFP Bias High :Alarm indicating that the SFP laser bias current of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_T…
1.3.6.1.4.1.20044.31.2.2.2.32.1.6Columnpm251dAlmClientVccLowAlaPortnread-onlycurrentClient SFP Power Supply Low :Alarm indicating that the SFP power supply of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_V…
1.3.6.1.4.1.20044.31.2.2.2.32.1.7Columnpm251dAlmClientVccHighAlaPortnread-onlycurrentClient SFP Power Supply High :Alarm indicating that the SFP power supply of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT…
1.3.6.1.4.1.20044.31.2.2.2.32.1.8Columnpm251dAlmClientTempLowAlaPortnread-onlycurrentClient SFP Temp Low :Alarm indicating that the SFP temperature of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_LOW_A…
1.3.6.1.4.1.20044.31.2.2.2.32.1.9Columnpm251dAlmClientTempHighAlaPortnread-onlycurrentClient SFP Temp High :Alarm indicating that the SFP temperature of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_TEMP_HIG…
1.3.6.1.4.1.20044.31.2.2.2.32.1.16Columnpm251dAlmClientRxPwrLowAlaPortnread-onlycurrentClient SFP Rx Power Low :Alarm indicating that the SFP input power of port is lower than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_PWR…
1.3.6.1.4.1.20044.31.2.2.2.32.1.17Columnpm251dAlmClientRxPwrHighAlaPortnread-onlycurrentClient SFP Rx Power High :Alarm indicating that the SFP input power of port is higher than the threshold value written in the SFP EEPROM <Condtype> CLIENT_RX_P…
1.3.6.1.4.1.20044.31.2.2.3Nodepm251dAlmPortCrit
1.3.6.1.4.1.20044.31.2.2.3.8Tablepm251dAlmsynthAlmClientTablenot-accessiblecurrentList of pm251dAlmsynthAlmClient Article
1.3.6.1.4.1.20044.31.2.2.3.8.1Rowpm251dAlmsynthAlmClientEntrynot-accessiblecurrentRow definition for the pm251dAlmsynthAlmClient table
1.3.6.1.4.1.20044.31.2.2.3.8.1.1Columnpm251dAlmsynthAlmClientIndexread-onlycurrentIndex definition for the pm251dAlmsynthAlmClient table
1.3.6.1.4.1.20044.31.2.2.3.8.1.2Columnpm251dAlmClientSfpAbsentPortnread-onlycurrentClient SFP not plugged :This OID indicates that the SFP module is not present in the client port. <Help> This alarm indicates if the client transceiver is pres…
1.3.6.1.4.1.20044.31.2.2.3.8.1.3Columnpm251dAlmClientDdmAbsentPortnread-onlycurrentDDM supported on Client SFP :This OID indicates that the Client SFP module does not support the Digital Diagnostic Monitoring function <Help> This status indic…
1.3.6.1.4.1.20044.31.2.2.3.8.1.5Columnpm251dAlmClientHwFailAccPortnread-onlycurrentClient HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. <Condtype> CLIENT_HW_FAIL_ACC_1 <Probcause> <Alarmtype> <Polar…
1.3.6.1.4.1.20044.31.2.2.3.8.1.6Columnpm251dAlmClientLsdPortnread-onlycurrentClient SFP optical Tx ON :This OID indicates the Client SFP transmitter output has shut down. <Help> This status indicates if the client transceiver laser is O…
1.3.6.1.4.1.20044.31.2.2.3.8.1.7Columnpm251dAlmClientLocalOosPortnread-onlycurrentLocal Client port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local c…
1.3.6.1.4.1.20044.31.2.2.3.8.1.8Columnpm251dAlmClientRemoteOosPortnread-onlycurrentRemote Client port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remot…
1.3.6.1.4.1.20044.31.2.2.3.8.1.9Columnpm251dAlmClientDwCaisPortnread-onlycurrentClient AIS inserted :This OID indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is…
1.3.6.1.4.1.20044.31.2.2.3.8.1.10Columnpm251dAlmClientSfpDdmWarningPortnread-onlycurrentWarning on Client SFP DDM :This OID indicates a warning is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Warning has been detecte…
1.3.6.1.4.1.20044.31.2.2.3.8.1.11Columnpm251dAlmClientSfpDdmAlmPortnread-onlycurrentAlarm on Client SFP DDM :This OID indicates an alarm is being received from the Client SFP DDM <Help> This alarm indicates if a DDM Alarm has been detected on …
1.3.6.1.4.1.20044.31.2.2.3.8.1.13Columnpm251dAlmClientFailAccPortnread-onlycurrentClient Access Fail :This OID indicates a failure on the Client port <Condtype> CLIENT_FAIL_ACC_1 <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.31.2.2.3.8.1.17Columnpm251dAlmClientUpCsfPortnread-onlycurrentClient Signal Fail inserted :This OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is cu…
1.3.6.1.4.1.20044.31.2.2.3.16Tablepm251dAlmaccessioAlmTablenot-accessiblecurrentList of pm251dAlmaccessioAlm Article
1.3.6.1.4.1.20044.31.2.2.3.16.1Rowpm251dAlmaccessioAlmEntrynot-accessiblecurrentRow definition for the pm251dAlmaccessioAlm table
1.3.6.1.4.1.20044.31.2.2.3.16.1.1Columnpm251dAlmaccessioAlmIndexread-onlycurrentIndex definition for the pm251dAlmaccessioAlm table
1.3.6.1.4.1.20044.31.2.2.3.16.1.2Columnpm251dAlmClientDwLasFailPortnread-onlycurrentClient SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the client port (this alarm reports the transmitter failure alarm …
1.3.6.1.4.1.20044.31.2.2.3.16.1.5Columnpm251dAlmClientUpLosPortnread-onlycurrentLoss of Optical signal on Client :This OID indicates that no signal is present on the SFP of the client port <Help> This alarm indicates if an optical signal i…
1.3.6.1.4.1.20044.31.2.2.3.72Tablepm251dAlmclientMapperDeAlmTablenot-accessiblecurrentList of pm251dAlmclientMapperDeAlm Article
1.3.6.1.4.1.20044.31.2.2.3.72.1Rowpm251dAlmclientMapperDeAlmEntrynot-accessiblecurrentRow definition for the pm251dAlmclientMapperDeAlm table
1.3.6.1.4.1.20044.31.2.2.3.72.1.1Columnpm251dAlmclientMapperDeAlmIndexread-onlycurrentIndex definition for the pm251dAlmclientMapperDeAlm table
1.3.6.1.4.1.20044.31.2.2.3.72.1.2Columnpm251dAlmClientUpAccOosPortnread-onlycurrentClient Loss of 10b/8b synchro :This OID indicates the upstream client input port has lost synchronization on its 10B/8B decoder <Help> This alarms indicates if…
1.3.6.1.4.1.20044.31.2.2.3.72.1.11Columnpm251dAlmClientUpBufferOvlPortnread-onlycurrentClient Upstream buffer overload :This OID indicates that the rate adaptation buffer for client port is in overload. <Help> This alarm indicates if there is a u…
1.3.6.1.4.1.20044.31.2.2.3.72.1.12Columnpm251dAlmClientDwCsfDetPortnread-onlycurrentClient Signal Fail detected :This OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client…
1.3.6.1.4.1.20044.31.2.2.3.72.1.15Columnpm251dAlmClientDwBufferOvlPortnread-onlycurrentClient Downstream buffer overload :This OID indicates that the de-mapper buffer for client port is in overload. <Help> This alarm indicates if there is a downs…
1.3.6.1.4.1.20044.31.2.2.3.72.1.16Columnpm251dAlmClientLoopAccFifoFailPortnread-onlydeprecatedClient port loop FIFO failure :active only in client loopback mode. <Condtype> CLIENT_LOOP_ACC_FIFO_FAIL_1 <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.31.2.2.3.104Tablepm251dAlmaccessioSdhAlarmTablenot-accessiblecurrentList of pm251dAlmaccessioSdhAlarm Article
1.3.6.1.4.1.20044.31.2.2.3.104.1Rowpm251dAlmaccessioSdhAlarmEntrynot-accessiblecurrentRow definition for the pm251dAlmaccessioSdhAlarm table
1.3.6.1.4.1.20044.31.2.2.3.104.1.1Columnpm251dAlmaccessioSdhAlarmIndexread-onlycurrentIndex definition for the pm251dAlmaccessioSdhAlarm table
1.3.6.1.4.1.20044.31.2.2.3.104.1.2Columnpm251dAlmLosTrscPortnread-onlycurrentClient Transceiver Loss of Signal :This OID indicates that a Loss of Signal condition has been detected on the client input transceiver <Condtype> LOS_TRSC_1 <…
1.3.6.1.4.1.20044.31.2.2.3.104.1.3Columnpm251dAlmFifoErrPortnread-onlycurrentClient transceiver Fifo Error :This OID indicates that an error has been detected in the FIFO of the client transceiver <Condtype> FIFO_ERR_1 <Probcause> <Alar…
1.3.6.1.4.1.20044.31.2.2.3.104.1.4Columnpm251dAlmRxLossOfLockPortnread-onlycurrentClient Rx Clock Lock Error :This OID indicates the recovered receive clock of the client transceiver is not locked <Condtype> RX_LOSS_OF_LOCK_1 <Probcause> <Al…
1.3.6.1.4.1.20044.31.2.2.3.104.1.5Columnpm251dAlmTxLossOfLockPortnread-onlycurrentClient Tx Clock Lock Error :This OID indicates that the transmit clock of the client transceiver is not locked <Condtype> TX_LOSS_OF_LOCK_1 <Probcause> <Alarmt…
1.3.6.1.4.1.20044.31.2.2.3.104.1.6Columnpm251dAlmClientAisDetPortnread-onlycurrentMS-AIS detected on client input :This OID indicates that a MS-AIS has been detected on the client input stream <Help> This alarm indicates if there is a MS-AIS…
1.3.6.1.4.1.20044.31.2.2.3.104.1.7Columnpm251dAlmClientRdiDetPortnread-onlycurrentMS-RDI detected on client input :This OID indicates that a MS-RDI has been detected on the client input stream <Help> This alarm indicates if there is a MS-RDI…
1.3.6.1.4.1.20044.31.2.2.3.104.1.8Columnpm251dAlmClientOofPortnread-onlycurrentClient Rx Out Of Frame :This OID indicates that an Out Of Frame condition has been detected on the client input stream <Help> This alarm indicates if there is …
1.3.6.1.4.1.20044.31.2.3Nodepm251dAlmLine
1.3.6.1.4.1.20044.31.2.3.1Nodepm251dAlmLineNurg
1.3.6.1.4.1.20044.31.2.3.1.130Tablepm251dAlmlineDownS1Tablenot-accessiblecurrentList of pm251dAlmlineDownS1 Article
1.3.6.1.4.1.20044.31.2.3.1.130.1Rowpm251dAlmlineDownS1Entrynot-accessiblecurrentRow definition for the pm251dAlmlineDownS1 table
1.3.6.1.4.1.20044.31.2.3.1.130.1.1Columnpm251dAlmlineDownS1Indexread-onlycurrentIndex definition for the pm251dAlmlineDownS1 table
1.3.6.1.4.1.20044.31.2.3.1.130.1.2Columnpm251dAlmlineDownS1Portnread-onlycurrentLine 1 S1 Extracted Value :This gives the value of S1 extracted from the overhead of the received OC-48c/STM-16c signal on the line 1 <Condtype> LINE_DW_S1_8_1…
1.3.6.1.4.1.20044.31.2.3.1.131Tablepm251dAlmlineDownK1Tablenot-accessiblecurrentList of pm251dAlmlineDownK1 Article
1.3.6.1.4.1.20044.31.2.3.1.131.1Rowpm251dAlmlineDownK1Entrynot-accessiblecurrentRow definition for the pm251dAlmlineDownK1 table
1.3.6.1.4.1.20044.31.2.3.1.131.1.1Columnpm251dAlmlineDownK1Indexread-onlycurrentIndex definition for the pm251dAlmlineDownK1 table
1.3.6.1.4.1.20044.31.2.3.1.131.1.2Columnpm251dAlmlineDownK1Portnread-onlycurrentLine 1 K1 Extracted Value :This gives the value of K1 extracted from the overhead of the received OC-48c/STM-16c signal on the line 1 <Condtype> LINE_DW_K1_8_1…
1.3.6.1.4.1.20044.31.2.3.1.132Tablepm251dAlmlineDownK2Tablenot-accessiblecurrentList of pm251dAlmlineDownK2 Article
1.3.6.1.4.1.20044.31.2.3.1.132.1Rowpm251dAlmlineDownK2Entrynot-accessiblecurrentRow definition for the pm251dAlmlineDownK2 table
1.3.6.1.4.1.20044.31.2.3.1.132.1.1Columnpm251dAlmlineDownK2Indexread-onlycurrentIndex definition for the pm251dAlmlineDownK2 table
1.3.6.1.4.1.20044.31.2.3.1.132.1.2Columnpm251dAlmlineDownK2Portnread-onlycurrentLine 1 K2 Extracted Value :This gives the value of K2 extracted from the overhead of the received OC-48c/STM-16c signal on the line 1 <Condtype> LINE_DW_K2_8_1…
1.3.6.1.4.1.20044.31.2.3.1.164Tablepm251dAlmlineSfpWarnDdmTablenot-accessiblecurrentList of pm251dAlmlineSfpWarnDdm Article
1.3.6.1.4.1.20044.31.2.3.1.164.1Rowpm251dAlmlineSfpWarnDdmEntrynot-accessiblecurrentRow definition for the pm251dAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.31.2.3.1.164.1.1Columnpm251dAlmlineSfpWarnDdmIndexread-onlycurrentIndex definition for the pm251dAlmlineSfpWarnDdm table
1.3.6.1.4.1.20044.31.2.3.1.164.1.2Columnpm251dAlmLineTxPwLowWngPortnread-onlycurrentLine SFP Tx Power Low warning :Warning indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE…
1.3.6.1.4.1.20044.31.2.3.1.164.1.3Columnpm251dAlmLineTxPwrHighWngPortnread-onlycurrentLine SFP Tx Power High warning :Warning indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.31.2.3.1.164.1.4Columnpm251dAlmLineTxBiasLowWngPortnread-onlycurrentLine SFP Bias Low warning :Warning indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LI…
1.3.6.1.4.1.20044.31.2.3.1.164.1.5Columnpm251dAlmLineTxBiasHighWngPortnread-onlycurrentLine SFP Bias High warning :Warning indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.31.2.3.1.164.1.6Columnpm251dAlmLineVccLowWngPortnread-onlycurrentLine SFP Power Supply Low warning :Warning indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> …
1.3.6.1.4.1.20044.31.2.3.1.164.1.7Columnpm251dAlmLineVccHighWngPortnread-onlycurrentLine SFP Power Supply High warning :Warning indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype…
1.3.6.1.4.1.20044.31.2.3.1.164.1.8Columnpm251dAlmLineTempLowWngPortnread-onlycurrentLine SFP Temp Low warning :Warning indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP…
1.3.6.1.4.1.20044.31.2.3.1.164.1.9Columnpm251dAlmLineTempHighWngPortnread-onlycurrentLine SFP Temp High warning :Warning indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TE…
1.3.6.1.4.1.20044.31.2.3.1.164.1.16Columnpm251dAlmLineRxPwrLowWngPortnread-onlycurrentLine SFP Rx Power Low warning :Warning indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_…
1.3.6.1.4.1.20044.31.2.3.1.164.1.17Columnpm251dAlmLineRxPwrHighWngPortnread-onlycurrentLine SFP Rx Power High warning :Warning indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LIN…
1.3.6.1.4.1.20044.31.2.3.2Nodepm251dAlmLineUrg
1.3.6.1.4.1.20044.31.2.3.2.162Tablepm251dAlmlineSfpAlaDdmTablenot-accessiblecurrentList of pm251dAlmlineSfpAlaDdm Article
1.3.6.1.4.1.20044.31.2.3.2.162.1Rowpm251dAlmlineSfpAlaDdmEntrynot-accessiblecurrentRow definition for the pm251dAlmlineSfpAlaDdm table
1.3.6.1.4.1.20044.31.2.3.2.162.1.1Columnpm251dAlmlineSfpAlaDdmIndexread-onlycurrentIndex definition for the pm251dAlmlineSfpAlaDdm table
1.3.6.1.4.1.20044.31.2.3.2.162.1.2Columnpm251dAlmLineTxPwrLowAlaPortnread-onlycurrentLine SFP Tx Power Low :Alarm indicating that the SFP output power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_LO…
1.3.6.1.4.1.20044.31.2.3.2.162.1.3Columnpm251dAlmLineTxPwrHighAlaPortnread-onlycurrentLine SFP Tx Power High :Alarm indicating that the SFP output power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_PWR_…
1.3.6.1.4.1.20044.31.2.3.2.162.1.4Columnpm251dAlmLineTxBiasLowAlaPortnread-onlycurrentLine SFP Bias Low :Alarm indicating that the SFP laser bias current of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BIAS…
1.3.6.1.4.1.20044.31.2.3.2.162.1.5Columnpm251dAlmLineTxBiasHighAlaPortnread-onlycurrentLine SFP Bias High :Alarm indicating that the SFP laser bias current of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TX_BI…
1.3.6.1.4.1.20044.31.2.3.2.162.1.6Columnpm251dAlmLineVccLowAlaPortnread-onlycurrentLine SFP Power Supply Low :Alarm indicating that the SFP power supply of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC_L…
1.3.6.1.4.1.20044.31.2.3.2.162.1.7Columnpm251dAlmLineVccHighAlaPortnread-onlycurrentLine SFP Power Supply High :Alarm indicating that the SFP power supply of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_VCC…
1.3.6.1.4.1.20044.31.2.3.2.162.1.8Columnpm251dAlmLineTempLowAlaPortnread-onlycurrentLine SFP Temp Low :Alarm indicating that the SFP temperature of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_LOW_ALA_1…
1.3.6.1.4.1.20044.31.2.3.2.162.1.9Columnpm251dAlmLineTempHighAlaPortnread-onlycurrentLine SFP Temp High :Alarm indicating that the SFP temperature of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_TEMP_HIGH_AL…
1.3.6.1.4.1.20044.31.2.3.2.162.1.16Columnpm251dAlmLineRxPwrLowAlaPortnread-onlycurrentLine SFP Rx Power Low :Alarm indicating that the SFP input power of Line is lower than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_LOW…
1.3.6.1.4.1.20044.31.2.3.2.162.1.17Columnpm251dAlmLineRxPwrHighAlaPortnread-onlycurrentLine SFP Rx Power High :Alarm indicating that the SFP input power of Line is higher than the threshold value written in the SFP EEPROM <Condtype> LINE_RX_PWR_H…
1.3.6.1.4.1.20044.31.2.3.3Nodepm251dAlmLineCrit
1.3.6.1.4.1.20044.31.2.3.3.4Tablepm251dAlmsynthAlmLineTablenot-accessiblecurrentList of pm251dAlmsynthAlmLine Article
1.3.6.1.4.1.20044.31.2.3.3.4.1Rowpm251dAlmsynthAlmLineEntrynot-accessiblecurrentRow definition for the pm251dAlmsynthAlmLine table
1.3.6.1.4.1.20044.31.2.3.3.4.1.1Columnpm251dAlmsynthAlmLineIndexread-onlycurrentIndex definition for the pm251dAlmsynthAlmLine table
1.3.6.1.4.1.20044.31.2.3.3.4.1.2Columnpm251dAlmLineSfpAbsentPortnread-onlycurrentLine SFP present :This OID indicates that the SFP module is not present in the line port. <Help> This alarm indicates if the line transceiver is present. <Cond…
1.3.6.1.4.1.20044.31.2.3.3.4.1.3Columnpm251dAlmLineDdmAbsentPortnread-onlycurrentDDM supported on Line SFP :This OID indicates that the SFP module on line port does not support Digital Diagnostic Monitoring Functions <Help> This status indi…
1.3.6.1.4.1.20044.31.2.3.3.4.1.5Columnpm251dAlmLineHwFailPortnread-onlycurrentLine HW Fail :This OID indicates a failure condition on the Line port, the most probable cause being a HW issue <Condtype> LINE_HW_FAIL_2 <Probcause> <Alarmtyp…
1.3.6.1.4.1.20044.31.2.3.3.4.1.6Columnpm251dAlmLineLsdPortnread-onlycurrentLine SFP optical Tx ON :This OID indicates the SFP transmitter line output is shut down. <Help> This status indicates if the line transceiver laser is ON or OF…
1.3.6.1.4.1.20044.31.2.3.3.4.1.7Columnpm251dAlmLineLocalOosPortnread-onlycurrentLine port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service…
1.3.6.1.4.1.20044.31.2.3.3.4.1.9Columnpm251dAlmLineUpRdiInsPortnread-onlycurrentRDI inserted on Line :This OID indicates an upstream RDI has been inserted on the outgoing 2.5 Gb/s SDH/SONET signal. <Help> This status indicates if a RDI is …
1.3.6.1.4.1.20044.31.2.3.3.4.1.10Columnpm251dAlmLineDdmWarningPortnread-onlycurrentWarning on Line SFP DDM :This OID indicates a warning is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Warning has been…
1.3.6.1.4.1.20044.31.2.3.3.4.1.11Columnpm251dAlmLineDdmAlmPortnread-onlycurrentAlarm on Line SFP DDM :This OID indicates an alarm is present coming out of Line optical interface DDM <Help> This alarm indicates if a DDM Alarm has been dete…
1.3.6.1.4.1.20044.31.2.3.3.4.1.13Columnpm251dAlmLineFailPortnread-onlycurrentLine Fail :This OID indicates a failure condition on the Line. <Condtype> LINE_FAIL_2 <Probcause> <Alarmtype> <Polarity> (2)
1.3.6.1.4.1.20044.31.2.3.3.128Tablepm251dAlmlineDfrmAlmTablenot-accessiblecurrentList of pm251dAlmlineDfrmAlm Article
1.3.6.1.4.1.20044.31.2.3.3.128.1Rowpm251dAlmlineDfrmAlmEntrynot-accessiblecurrentRow definition for the pm251dAlmlineDfrmAlm table
1.3.6.1.4.1.20044.31.2.3.3.128.1.1Columnpm251dAlmlineDfrmAlmIndexread-onlycurrentIndex definition for the pm251dAlmlineDfrmAlm table
1.3.6.1.4.1.20044.31.2.3.3.128.1.2Columnpm251dAlmLineDwAisDetPortnread-onlycurrentAIS detected on line input :This OID indicates that an AIS has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if there is an…
1.3.6.1.4.1.20044.31.2.3.3.128.1.3Columnpm251dAlmLineDwRdiDetPortnread-onlycurrentRDI detected on line input :This OID indicates that an RDI has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if there is a …
1.3.6.1.4.1.20044.31.2.3.3.128.1.4Columnpm251dAlmLineDwOofPortnread-onlycurrentSONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if t…
1.3.6.1.4.1.20044.31.2.3.3.128.1.5Columnpm251dAlmLineDwLofPortnread-onlycurrentSONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming OC-48c/STM-16c input signal <Help> This alarm indicates if …
1.3.6.1.4.1.20044.31.2.3.3.160Tablepm251dAlmlineIoAlmTablenot-accessiblecurrentList of pm251dAlmlineIoAlm Article
1.3.6.1.4.1.20044.31.2.3.3.160.1Rowpm251dAlmlineIoAlmEntrynot-accessiblecurrentRow definition for the pm251dAlmlineIoAlm table
1.3.6.1.4.1.20044.31.2.3.3.160.1.1Columnpm251dAlmlineIoAlmIndexread-onlycurrentIndex definition for the pm251dAlmlineIoAlm table
1.3.6.1.4.1.20044.31.2.3.3.160.1.2Columnpm251dAlmLineUpLasFailPortnread-onlycurrentLine SFP Tx Failed :This OID indicates that the transmitter fails for the SFP plugged into the line port #n (this alarm reports the transmitter failure alarm g…
1.3.6.1.4.1.20044.31.2.3.3.160.1.5Columnpm251dAlmLineDwLosPortnread-onlycurrentLine input Loss of Signal :This OID indicates that no signal is present on the SFP of the line port #n <Help> This alarm indicates if an optical signal is dete…
1.3.6.1.4.1.20044.31.3Nodepm251dmeasures
1.3.6.1.4.1.20044.31.3.1Nodepm251dMesrOther
1.3.6.1.4.1.20044.31.3.2Nodepm251dMesrPort
1.3.6.1.4.1.20044.31.3.2.16Tablepm251dMesrclientTempMeasTablenot-accessiblecurrentList of pm251dMesrclientTempMeas Article
1.3.6.1.4.1.20044.31.3.2.16.1Rowpm251dMesrclientTempMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrclientTempMeas table
1.3.6.1.4.1.20044.31.3.2.16.1.1Columnpm251dMesrclientTempMeasIndexread-onlycurrentIndex definition for the pm251dMesrclientTempMeas table
1.3.6.1.4.1.20044.31.3.2.16.1.2Columnpm251dMesrclientTempMeasPortnread-onlycurrentClient SFP Temperature :This OID gives the temperature value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit …
1.3.6.1.4.1.20044.31.3.2.24Tablepm251dMesrclientVoltMeasTablenot-accessiblecurrentList of pm251dMesrclientVoltMeas Article
1.3.6.1.4.1.20044.31.3.2.24.1Rowpm251dMesrclientVoltMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrclientVoltMeas table
1.3.6.1.4.1.20044.31.3.2.24.1.1Columnpm251dMesrclientVoltMeasIndexread-onlycurrentIndex definition for the pm251dMesrclientVoltMeas table
1.3.6.1.4.1.20044.31.3.2.24.1.2Columnpm251dMesrclientVoltMeasPortnread-onlycurrentClient SFP Power Supply :This OID gives the 3V3 voltage value of the client SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit =…
1.3.6.1.4.1.20044.31.3.2.32Tablepm251dMesrclientBiasMeasTablenot-accessiblecurrentList of pm251dMesrclientBiasMeas Article
1.3.6.1.4.1.20044.31.3.2.32.1Rowpm251dMesrclientBiasMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrclientBiasMeas table
1.3.6.1.4.1.20044.31.3.2.32.1.1Columnpm251dMesrclientBiasMeasIndexread-onlycurrentIndex definition for the pm251dMesrclientBiasMeas table
1.3.6.1.4.1.20044.31.3.2.32.1.2Columnpm251dMesrclientBiasMeasPortnread-onlycurrentClient SFP Laser Bias :This OID gives the bias value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> Th…
1.3.6.1.4.1.20044.31.3.2.40Tablepm251dMesrclientTxpwrMeasTablenot-accessiblecurrentList of pm251dMesrclientTxpwrMeas Article
1.3.6.1.4.1.20044.31.3.2.40.1Rowpm251dMesrclientTxpwrMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrclientTxpwrMeas table
1.3.6.1.4.1.20044.31.3.2.40.1.1Columnpm251dMesrclientTxpwrMeasIndexread-onlycurrentIndex definition for the pm251dMesrclientTxpwrMeas table
1.3.6.1.4.1.20044.31.3.2.40.1.2Columnpm251dMesrclientTxpwrMeasPortnread-onlycurrentClient SFP Transmitted Power :This OID gives the transmit power value of the Client SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-…
1.3.6.1.4.1.20044.31.3.2.48Tablepm251dMesrclientRxpwrMeasTablenot-accessiblecurrentList of pm251dMesrclientRxpwrMeas Article
1.3.6.1.4.1.20044.31.3.2.48.1Rowpm251dMesrclientRxpwrMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrclientRxpwrMeas table
1.3.6.1.4.1.20044.31.3.2.48.1.1Columnpm251dMesrclientRxpwrMeasIndexread-onlycurrentIndex definition for the pm251dMesrclientRxpwrMeas table
1.3.6.1.4.1.20044.31.3.2.48.1.2Columnpm251dMesrclientRxpwrMeasPortnread-onlycurrentClient SFP Received Power :This OID gives the receive power value of the Client SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (U…
1.3.6.1.4.1.20044.31.3.3Nodepm251dMesrLine
1.3.6.1.4.1.20044.31.3.3.160Tablepm251dMesrlineTempMeasTablenot-accessiblecurrentList of pm251dMesrlineTempMeas Article
1.3.6.1.4.1.20044.31.3.3.160.1Rowpm251dMesrlineTempMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrlineTempMeas table
1.3.6.1.4.1.20044.31.3.3.160.1.1Columnpm251dMesrlineTempMeasIndexread-onlycurrentIndex definition for the pm251dMesrlineTempMeas table
1.3.6.1.4.1.20044.31.3.3.160.1.2Columnpm251dMesrlineTempMeasPortnread-onlycurrentLine SFP Temperature :This OID gives the temperature value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C)…
1.3.6.1.4.1.20044.31.3.3.161Tablepm251dMesrlineVoltMeasTablenot-accessiblecurrentList of pm251dMesrlineVoltMeas Article
1.3.6.1.4.1.20044.31.3.3.161.1Rowpm251dMesrlineVoltMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrlineVoltMeas table
1.3.6.1.4.1.20044.31.3.3.161.1.1Columnpm251dMesrlineVoltMeasIndexread-onlycurrentIndex definition for the pm251dMesrlineVoltMeas table
1.3.6.1.4.1.20044.31.3.3.161.1.2Columnpm251dMesrlineVoltMeasPortnread-onlycurrentLine SFP Power Supply :This OID gives the 3V3 voltage value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) …
1.3.6.1.4.1.20044.31.3.3.162Tablepm251dMesrlineBiasMeasTablenot-accessiblecurrentList of pm251dMesrlineBiasMeas Article
1.3.6.1.4.1.20044.31.3.3.162.1Rowpm251dMesrlineBiasMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrlineBiasMeas table
1.3.6.1.4.1.20044.31.3.3.162.1.1Columnpm251dMesrlineBiasMeasIndexread-onlycurrentIndex definition for the pm251dMesrlineBiasMeas table
1.3.6.1.4.1.20044.31.3.3.162.1.2Columnpm251dMesrlineBiasMeasPortnread-onlycurrentLine SFP Laser Bias :This OID gives the bias value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This m…
1.3.6.1.4.1.20044.31.3.3.163Tablepm251dMesrlineTxpwrMeasTablenot-accessiblecurrentList of pm251dMesrlineTxpwrMeas Article
1.3.6.1.4.1.20044.31.3.3.163.1Rowpm251dMesrlineTxpwrMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrlineTxpwrMeas table
1.3.6.1.4.1.20044.31.3.3.163.1.1Columnpm251dMesrlineTxpwrMeasIndexread-onlycurrentIndex definition for the pm251dMesrlineTxpwrMeas table
1.3.6.1.4.1.20044.31.3.3.163.1.2Columnpm251dMesrlineTxpwrMeasPortnread-onlycurrentLine SFP Transmitted Power :This OID gives the transmit power value of the Line SFP, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) …
1.3.6.1.4.1.20044.31.3.3.164Tablepm251dMesrlineRxpwrMeasTablenot-accessiblecurrentList of pm251dMesrlineRxpwrMeas Article
1.3.6.1.4.1.20044.31.3.3.164.1Rowpm251dMesrlineRxpwrMeasEntrynot-accessiblecurrentRow definition for the pm251dMesrlineRxpwrMeas table
1.3.6.1.4.1.20044.31.3.3.164.1.1Columnpm251dMesrlineRxpwrMeasIndexread-onlycurrentIndex definition for the pm251dMesrlineRxpwrMeas table
1.3.6.1.4.1.20044.31.3.3.164.1.2Columnpm251dMesrlineRxpwrMeasPortnread-onlycurrentLine SFP Received Power :This OID gives the receive power value of the Line SFP, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit …
1.3.6.1.4.1.20044.31.4Nodepm251dcounters
1.3.6.1.4.1.20044.31.4.1Nodepm251dCntOther
1.3.6.1.4.1.20044.31.4.2Nodepm251dCntPort
1.3.6.1.4.1.20044.31.4.2.16Tablepm251dCntclientUpRaRemCntTablenot-accessiblecurrentList of pm251dCntclientUpRaRemCnt Article
1.3.6.1.4.1.20044.31.4.2.16.1Rowpm251dCntclientUpRaRemCntEntrynot-accessiblecurrentRow definition for the pm251dCntclientUpRaRemCnt table
1.3.6.1.4.1.20044.31.4.2.16.1.1Columnpm251dCntclientUpRaRemCntIndexread-onlycurrentIndex definition for the pm251dCntclientUpRaRemCnt table
1.3.6.1.4.1.20044.31.4.2.16.1.2Columnpm251dCntclientUpRaRemCntValuePortnread-onlycurrentClient Rate Adapt. words removal :This counter is incremented each time a rate adaptation 10B word is removed from the Client input stream
1.3.6.1.4.1.20044.31.4.2.16.1.3Columnpm251dCntclientUpRaRemCntErrorPortnread-onlycurrentClient counter error :This OID when set indicates the rate adaptation removal counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.2.16.1.4Columnpm251dCntclientUpRaRemCntOverloadPortnread-onlycurrentClient counter overload :This OID when set indicates a rate adaptation removal counter overload on Port
1.3.6.1.4.1.20044.31.4.2.24Tablepm251dCntclientUpRaInsCntTablenot-accessiblecurrentList of pm251dCntclientUpRaInsCnt Article
1.3.6.1.4.1.20044.31.4.2.24.1Rowpm251dCntclientUpRaInsCntEntrynot-accessiblecurrentRow definition for the pm251dCntclientUpRaInsCnt table
1.3.6.1.4.1.20044.31.4.2.24.1.1Columnpm251dCntclientUpRaInsCntIndexread-onlycurrentIndex definition for the pm251dCntclientUpRaInsCnt table
1.3.6.1.4.1.20044.31.4.2.24.1.2Columnpm251dCntclientUpRaInsCntValuePortnread-onlycurrentClient Rate Adapt. words insertion :This counter is incremented each time a rate adaptation 10B word is inserted in the Client input stream
1.3.6.1.4.1.20044.31.4.2.24.1.3Columnpm251dCntclientUpRaInsCntErrorPortnread-onlycurrentClient counter error :This OID when set indicates the rate adaptation insertion counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.2.24.1.4Columnpm251dCntclientUpRaInsCntOverloadPortnread-onlycurrentClient counter overload :This OID when set indicates a rate adaptation insertion counter overload on Port
1.3.6.1.4.1.20044.31.4.2.32Tablepm251dCntclientUpDispErrCntTablenot-accessiblecurrentList of pm251dCntclientUpDispErrCnt Article
1.3.6.1.4.1.20044.31.4.2.32.1Rowpm251dCntclientUpDispErrCntEntrynot-accessiblecurrentRow definition for the pm251dCntclientUpDispErrCnt table
1.3.6.1.4.1.20044.31.4.2.32.1.1Columnpm251dCntclientUpDispErrCntIndexread-onlycurrentIndex definition for the pm251dCntclientUpDispErrCnt table
1.3.6.1.4.1.20044.31.4.2.32.1.2Columnpm251dCntclientUpDispErrCntValuePortnread-onlycurrentClient Input Error counter :This counter is incremented each time a running disparity error or a 10b/8b decoding violation is detected on the Client input stre…
1.3.6.1.4.1.20044.31.4.2.32.1.3Columnpm251dCntclientUpDispErrCntErrorPortnread-onlycurrentClient counter error :This OID when set indicates the 10B/8B decoding violations counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.2.32.1.4Columnpm251dCntclientUpDispErrCntOverloadPortnread-onlycurrentClient counter overload :This OID when set indicates a 10B/8B decoding violations counter overload on Port
1.3.6.1.4.1.20044.31.4.2.40Tablepm251dCntclientUpTimCntTablenot-accessiblecurrentList of pm251dCntclientUpTimCnt Article
1.3.6.1.4.1.20044.31.4.2.40.1Rowpm251dCntclientUpTimCntEntrynot-accessiblecurrentRow definition for the pm251dCntclientUpTimCnt table
1.3.6.1.4.1.20044.31.4.2.40.1.1Columnpm251dCntclientUpTimCntIndexread-onlycurrentIndex definition for the pm251dCntclientUpTimCnt table
1.3.6.1.4.1.20044.31.4.2.40.1.2Columnpm251dCntclientUpTimCntValuePortnread-onlycurrentClient upstream timer counter :This is the timing counter dedicated to the upstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.31.4.2.40.1.3Columnpm251dCntclientUpTimCntErrorPortnread-onlycurrentClient counter error :This OID when set indicates the upstream timing counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.2.40.1.4Columnpm251dCntclientUpTimCntOverloadPortnread-onlycurrentClient counter overload :This OID when set indicates a upstream timing counter overload on Port
1.3.6.1.4.1.20044.31.4.2.64Tablepm251dCntclientDwCbipCntTablenot-accessiblecurrentList of pm251dCntclientDwCbipCnt Article
1.3.6.1.4.1.20044.31.4.2.64.1Rowpm251dCntclientDwCbipCntEntrynot-accessiblecurrentRow definition for the pm251dCntclientDwCbipCnt table
1.3.6.1.4.1.20044.31.4.2.64.1.1Columnpm251dCntclientDwCbipCntIndexread-onlycurrentIndex definition for the pm251dCntclientDwCbipCnt table
1.3.6.1.4.1.20044.31.4.2.64.1.2Columnpm251dCntclientDwCbipCntValuePortnread-onlycurrentClient CBIP counter :This counter is incremented each time a CBIP parity error is detected on the Client output stream
1.3.6.1.4.1.20044.31.4.2.64.1.3Columnpm251dCntclientDwCbipCntErrorPortnread-onlycurrentClient counter error :This OID when set indicates the CBIP error counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.2.64.1.4Columnpm251dCntclientDwCbipCntOverloadPortnread-onlycurrentClient CBIP counter overload :This OID when set indicates a CBIP error counter overload on Port
1.3.6.1.4.1.20044.31.4.2.72Tablepm251dCntclientDwTimCntTablenot-accessiblecurrentList of pm251dCntclientDwTimCnt Article
1.3.6.1.4.1.20044.31.4.2.72.1Rowpm251dCntclientDwTimCntEntrynot-accessiblecurrentRow definition for the pm251dCntclientDwTimCnt table
1.3.6.1.4.1.20044.31.4.2.72.1.1Columnpm251dCntclientDwTimCntIndexread-onlycurrentIndex definition for the pm251dCntclientDwTimCnt table
1.3.6.1.4.1.20044.31.4.2.72.1.2Columnpm251dCntclientDwTimCntValuePortnread-onlycurrentClient downstream timer counter :This is the timing counter dedicated to the downstream access counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.31.4.2.72.1.3Columnpm251dCntclientDwTimCntErrorPortnread-onlycurrentClient counter error :This OID when set indicates the downstream timer counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.2.72.1.4Columnpm251dCntclientDwTimCntOverloadPortnread-onlycurrentClient counter overload :This OID when set indicates a downstream timer counter overload on Port
1.3.6.1.4.1.20044.31.4.3Nodepm251dCntLine
1.3.6.1.4.1.20044.31.4.3.152Tablepm251dCntlineDfrmB1ErrCntTablenot-accessiblecurrentList of pm251dCntlineDfrmB1ErrCnt Article
1.3.6.1.4.1.20044.31.4.3.152.1Rowpm251dCntlineDfrmB1ErrCntEntrynot-accessiblecurrentRow definition for the pm251dCntlineDfrmB1ErrCnt table
1.3.6.1.4.1.20044.31.4.3.152.1.1Columnpm251dCntlineDfrmB1ErrCntIndexread-onlycurrentIndex definition for the pm251dCntlineDfrmB1ErrCnt table
1.3.6.1.4.1.20044.31.4.3.152.1.2Columnpm251dCntlineDfrmB1ErrCntValuePortnread-onlycurrentLine B1 error counter :This counter is incremented each time a B1 error is detected on the Deframer input stream. <Help> This counter gives the number of B1 er…
1.3.6.1.4.1.20044.31.4.3.152.1.3Columnpm251dCntlineDfrmB1ErrCntErrorPortnread-onlycurrentLine counter error :This OID when set indicates the B1 error counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.3.152.1.4Columnpm251dCntlineDfrmB1ErrCntOverloadPortnread-onlycurrentLine counter overload :This OID when set indicates a B1 error counter overload on Port
1.3.6.1.4.1.20044.31.4.3.153Tablepm251dCntlineDfrmTimCntTablenot-accessiblecurrentList of pm251dCntlineDfrmTimCnt Article
1.3.6.1.4.1.20044.31.4.3.153.1Rowpm251dCntlineDfrmTimCntEntrynot-accessiblecurrentRow definition for the pm251dCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.31.4.3.153.1.1Columnpm251dCntlineDfrmTimCntIndexread-onlycurrentIndex definition for the pm251dCntlineDfrmTimCnt table
1.3.6.1.4.1.20044.31.4.3.153.1.2Columnpm251dCntlineDfrmTimCntValuePortnread-onlycurrentLine timer counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us.
1.3.6.1.4.1.20044.31.4.3.153.1.3Columnpm251dCntlineDfrmTimCntErrorPortnread-onlycurrentLine counter error :This OID when set indicates the deframer timer counter value is invalid on Port
1.3.6.1.4.1.20044.31.4.3.153.1.4Columnpm251dCntlineDfrmTimCntOverloadPortnread-onlycurrentLine counter overload :This OID when set indicates a deframer timer counter overload on Port
1.3.6.1.4.1.20044.31.4.3.154Tablepm251dCntdfrmPrimLineErrCntTablenot-accessiblecurrentList of pm251dCntdfrmPrimLineErrCnt Article
1.3.6.1.4.1.20044.31.4.3.154.1Rowpm251dCntdfrmPrimLineErrCntEntrynot-accessiblecurrentRow definition for the pm251dCntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.31.4.3.154.1.1Columnpm251dCntdfrmPrimLineErrCntIndexread-onlycurrentIndex definition for the pm251dCntdfrmPrimLineErrCnt table
1.3.6.1.4.1.20044.31.4.3.154.1.2Columnpm251dCntdfrmPrimLineErrCntValuePortnread-onlycurrentFEC Corrected Errors counter :This counter is incremented each time the FEC is correcting an error on the line input stream. <Help> This counter gives the numb…
1.3.6.1.4.1.20044.31.4.3.154.1.3Columnpm251dCntdfrmPrimLineErrCntErrorPortnread-onlycurrent
1.3.6.1.4.1.20044.31.4.3.154.1.4Columnpm251dCntdfrmPrimLineErrCntOverloadPortnread-onlycurrent
1.3.6.1.4.1.20044.31.4.259Scalarpm251dCntCountersResetread-writecurrentCounters Reset : This OID resets and restarts all the counters
1.3.6.1.4.1.20044.31.4.260Scalarpm251dCntCountersStopread-writecurrentCounters stop : This OID stops all the counters
1.3.6.1.4.1.20044.31.6Nodepm251dcontrolsWrite
1.3.6.1.4.1.20044.31.6.1Nodepm251dCtrlOther
1.3.6.1.4.1.20044.31.6.1.1Nodepm251dCtrlconfMgnt1
1.3.6.1.4.1.20044.31.6.1.1.1Scalarpm251dCtrlConf1Load1read-writecurrentLoad Configuration Tables set n�1 :When set this OID enables loading from flash configuration1 into the PM.
1.3.6.1.4.1.20044.31.6.1.1.2Scalarpm251dCtrlConf2Load1read-writecurrentLoad Configuration Tables set n�2 :When set this OID enables loading from flash configuration2 into the PM.
1.3.6.1.4.1.20044.31.6.1.1.10Scalarpm251dCtrlConf2Flash1read-writecurrentWrite Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. <Help> This control saves the customer configura…
1.3.6.1.4.1.20044.31.6.1.1.14Scalarpm251dCtrlConf2Clear1read-writecurrentClear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. <Help> This control restores the default configuration o…
1.3.6.1.4.1.20044.31.6.1.4Nodepm251dCtrlsynth4
1.3.6.1.4.1.20044.31.6.1.4.1Scalarpm251dCtrlCorrelatOnread-writecurrentEnable Alarm Correlation :This OID enables the alarm correlation in the PM.
1.3.6.1.4.1.20044.31.6.1.4.2Scalarpm251dCtrlCorrelatOffread-writecurrentDisable Alarm Correlation :This OID disables the alarm correlation in the PM.
1.3.6.1.4.1.20044.31.6.1.5Nodepm251dCtrlswMgnt
1.3.6.1.4.1.20044.31.6.1.5.2Scalarpm251dCtrlColdResetread-writecurrentPM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. <Help> …
1.3.6.1.4.1.20044.31.6.1.5.3Scalarpm251dCtrlWarmResetread-writecurrentPM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. <Help> Th…
1.3.6.1.4.1.20044.31.6.1.5.5Scalarpm251dCtrlLoadSwBank1read-writecurrentSet Software nb 1 as active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. <Help> This controls selects the first SW…
1.3.6.1.4.1.20044.31.6.1.5.6Scalarpm251dCtrlLoadSwBank2read-writecurrentSet Software nb 2 as active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. <Help> This controls selects the second S…
1.3.6.1.4.1.20044.31.6.1.6Nodepm251dCtrlgwMgnt
1.3.6.1.4.1.20044.31.6.1.6.1Scalarpm251dCtrlCurrentGwResetread-writecurrentActive Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting.
1.3.6.1.4.1.20044.31.6.1.6.5Scalarpm251dCtrlLoadGwBank1read-writecurrentSet Gateware nb 1 as active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.31.6.1.6.6Scalarpm251dCtrlLoadGwBank2read-writecurrentSet Gateware nb 2 as active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.31.6.1.6.7Scalarpm251dCtrlLoadGwBank3read-writecurrentSet Gateware nb 3 as active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. <Help> This c…
1.3.6.1.4.1.20044.31.6.1.6.8Scalarpm251dCtrlLoadGwBank4read-writecurrentSet Gateware nb 4 as active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset.
1.3.6.1.4.1.20044.31.6.1.192Nodepm251dCtrlledTest
1.3.6.1.4.1.20044.31.6.1.192.1Scalarpm251dCtrlGreenLedread-writecurrentGreen Leds Test :This OID switches on all the green Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to green
1.3.6.1.4.1.20044.31.6.1.192.2Scalarpm251dCtrlRedLedread-writecurrentRed Leds Test :This OID switches on all the red Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to red
1.3.6.1.4.1.20044.31.6.1.192.3Scalarpm251dCtrlLedOffread-writecurrentLeds Off :This OID switches off all the Leds as a test feature. <Help> This control initiates a test leds turning all the LEDs to OFF
1.3.6.1.4.1.20044.31.6.1.193Nodepm251dCtrlmoduleOosMode
1.3.6.1.4.1.20044.31.6.1.193.1Scalarpm251dCtrlModuleOosModeread-writecurrentPM Out Of Service :This OID sets the PM253 Out Of Service <Help> This control defines the service state of the complete module
1.3.6.1.4.1.20044.31.6.1.197Nodepm251dCtrlmaintenanceMode
1.3.6.1.4.1.20044.31.6.1.197.1Scalarpm251dCtrlMaintenanceModeread-writecurrentEnable Maintenance :This OID enables the maintenance mode on the PM. <Help> This control enables the maintenance mode on the PM.
1.3.6.1.4.1.20044.31.6.1.198Nodepm251dCtrldccEnable
1.3.6.1.4.1.20044.31.6.1.198.1Scalarpm251dCtrlDccEnableread-writecurrentDCC Mode :This OID enables the DCC mode on the PM <Help> This control enables the DCC mode on the PM
1.3.6.1.4.1.20044.31.6.2Nodepm251dCtrlPort
1.3.6.1.4.1.20044.31.6.2.16Tablepm251dCtrlclientAccessLoopTablenot-accessiblecurrentList of pm251dCtrlclientAccessLoop Article
1.3.6.1.4.1.20044.31.6.2.16.1Rowpm251dCtrlclientAccessLoopEntrynot-accessiblecurrentRow definition for the pm251dCtrlclientAccessLoop table
1.3.6.1.4.1.20044.31.6.2.16.1.1Columnpm251dCtrlclientAccessLoopIndexread-onlycurrentIndex definition for the pm251dCtrlclientAccessLoop table
1.3.6.1.4.1.20044.31.6.2.16.1.2Columnpm251dCtrlclientAccessLoopPortnread-writecurrentClient Access Loop Back :This OID operates an access loopback on the Client port. <Help> This control defines the access loop back of the client port
1.3.6.1.4.1.20044.31.6.2.18Tablepm251dCtrlclientOosModeTablenot-accessiblecurrentList of pm251dCtrlclientOosMode Article
1.3.6.1.4.1.20044.31.6.2.18.1Rowpm251dCtrlclientOosModeEntrynot-accessiblecurrentRow definition for the pm251dCtrlclientOosMode table
1.3.6.1.4.1.20044.31.6.2.18.1.1Columnpm251dCtrlclientOosModeIndexread-onlycurrentIndex definition for the pm251dCtrlclientOosMode table
1.3.6.1.4.1.20044.31.6.2.18.1.2Columnpm251dCtrlclientOosModePortnread-writecurrentClient port Out of Service :This OID sets the client port Out Of Service <Help> This controls defines the service state of the client port
1.3.6.1.4.1.20044.31.6.2.20Tablepm251dCtrlclientSfpOnOffCtrlTablenot-accessiblecurrentList of pm251dCtrlclientSfpOnOffCtrl Article
1.3.6.1.4.1.20044.31.6.2.20.1Rowpm251dCtrlclientSfpOnOffCtrlEntrynot-accessiblecurrentRow definition for the pm251dCtrlclientSfpOnOffCtrl table
1.3.6.1.4.1.20044.31.6.2.20.1.1Columnpm251dCtrlclientSfpOnOffCtrlIndexread-onlycurrentIndex definition for the pm251dCtrlclientSfpOnOffCtrl table
1.3.6.1.4.1.20044.31.6.2.20.1.2Columnpm251dCtrlclientSfpOnOffCtrlPortnread-writecurrentClient SFP Optical Laser OFF :This OID switches off the Client SFP. <Help> This control defines the laser state of the client transceiver
1.3.6.1.4.1.20044.31.6.2.21Tablepm251dCtrlclientCsfUpInsTablenot-accessiblecurrentList of pm251dCtrlclientCsfUpIns Article
1.3.6.1.4.1.20044.31.6.2.21.1Rowpm251dCtrlclientCsfUpInsEntrynot-accessiblecurrentRow definition for the pm251dCtrlclientCsfUpIns table
1.3.6.1.4.1.20044.31.6.2.21.1.1Columnpm251dCtrlclientCsfUpInsIndexread-onlycurrentIndex definition for the pm251dCtrlclientCsfUpIns table
1.3.6.1.4.1.20044.31.6.2.21.1.2Columnpm251dCtrlclientCsfUpInsPortnread-writecurrentClient Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail fo…
1.3.6.1.4.1.20044.31.6.2.22Tablepm251dCtrlclientCaisDwInsTablenot-accessiblecurrentList of pm251dCtrlclientCaisDwIns Article
1.3.6.1.4.1.20044.31.6.2.22.1Rowpm251dCtrlclientCaisDwInsEntrynot-accessiblecurrentRow definition for the pm251dCtrlclientCaisDwIns table
1.3.6.1.4.1.20044.31.6.2.22.1.1Columnpm251dCtrlclientCaisDwInsIndexread-onlycurrentIndex definition for the pm251dCtrlclientCaisDwIns table
1.3.6.1.4.1.20044.31.6.2.22.1.2Columnpm251dCtrlclientCaisDwInsPortnread-writecurrentClient AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port
1.3.6.1.4.1.20044.31.6.3Nodepm251dCtrlLine
1.3.6.1.4.1.20044.31.6.3.67Nodepm251dCtrllineMsAis
1.3.6.1.4.1.20044.31.6.3.67.1Scalarpm251dCtrlLineMsAisread-writecurrentInsert MS-AIS/L-AIS on Lines output :This OID, when set, inserts an MS-AIS/L-AIS in the two outgoing STM-16/OC-48 signals.
1.3.6.1.4.1.20044.31.6.3.69Tablepm251dCtrlfecDisableTablenot-accessiblecurrentList of pm251dCtrlfecDisable Article
1.3.6.1.4.1.20044.31.6.3.69.1Rowpm251dCtrlfecDisableEntrynot-accessiblecurrentRow definition for the pm251dCtrlfecDisable table
1.3.6.1.4.1.20044.31.6.3.69.1.1Columnpm251dCtrlfecDisableIndexread-onlycurrentIndex definition for the pm251dCtrlfecDisable table
1.3.6.1.4.1.20044.31.6.3.69.1.2Columnpm251dCtrlfecDisablePortnread-writecurrentForward Error Correction inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input
1.3.6.1.4.1.20044.31.6.3.70Tablepm251dCtrllineUpS1Tablenot-accessiblecurrentList of pm251dCtrllineUpS1 Article
1.3.6.1.4.1.20044.31.6.3.70.1Rowpm251dCtrllineUpS1Entrynot-accessiblecurrentRow definition for the pm251dCtrllineUpS1 table
1.3.6.1.4.1.20044.31.6.3.70.1.1Columnpm251dCtrllineUpS1Indexread-onlycurrentIndex definition for the pm251dCtrllineUpS1 table
1.3.6.1.4.1.20044.31.6.3.70.1.2Columnpm251dCtrllineUpS1Portnread-writecurrentS1 value inserted on lines output :The value to be written in the S1 byte of the two upstream OC-48c/STM-16c signals is accessible through the present OID
1.3.6.1.4.1.20044.31.6.3.71Tablepm251dCtrllineUpK1Tablenot-accessiblecurrentList of pm251dCtrllineUpK1 Article
1.3.6.1.4.1.20044.31.6.3.71.1Rowpm251dCtrllineUpK1Entrynot-accessiblecurrentRow definition for the pm251dCtrllineUpK1 table
1.3.6.1.4.1.20044.31.6.3.71.1.1Columnpm251dCtrllineUpK1Indexread-onlycurrentIndex definition for the pm251dCtrllineUpK1 table
1.3.6.1.4.1.20044.31.6.3.71.1.2Columnpm251dCtrllineUpK1Portnread-writecurrentK1 value inserted on lines output :The value to be written in the K1 byte of the two upstream OC-48c/STM-16c signals is accessible through the present OID
1.3.6.1.4.1.20044.31.6.3.72Tablepm251dCtrllineUpK2Tablenot-accessiblecurrentList of pm251dCtrllineUpK2 Article
1.3.6.1.4.1.20044.31.6.3.72.1Rowpm251dCtrllineUpK2Entrynot-accessiblecurrentRow definition for the pm251dCtrllineUpK2 table
1.3.6.1.4.1.20044.31.6.3.72.1.1Columnpm251dCtrllineUpK2Indexread-onlycurrentIndex definition for the pm251dCtrllineUpK2 table
1.3.6.1.4.1.20044.31.6.3.72.1.2Columnpm251dCtrllineUpK2Portnread-writecurrentK2 value inserted on lines output :The value to be written in the K2 byte of the two upstream OC-48c/STM-16c signals is accessible through the present OID
1.3.6.1.4.1.20044.31.6.3.74Tablepm251dCtrllineOosModeTablenot-accessiblecurrentList of pm251dCtrllineOosMode Article
1.3.6.1.4.1.20044.31.6.3.74.1Rowpm251dCtrllineOosModeEntrynot-accessiblecurrentRow definition for the pm251dCtrllineOosMode table
1.3.6.1.4.1.20044.31.6.3.74.1.1Columnpm251dCtrllineOosModeIndexread-onlycurrentIndex definition for the pm251dCtrllineOosMode table
1.3.6.1.4.1.20044.31.6.3.74.1.2Columnpm251dCtrllineOosModePortnread-writecurrentLine port Out of Service :This OID sets the line port Out Of Service <Help> This control defines the service state of the line port
1.3.6.1.4.1.20044.31.6.3.160Tablepm251dCtrllineAccessLoopTablenot-accessiblecurrentList of pm251dCtrllineAccessLoop Article
1.3.6.1.4.1.20044.31.6.3.160.1Rowpm251dCtrllineAccessLoopEntrynot-accessiblecurrentRow definition for the pm251dCtrllineAccessLoop table
1.3.6.1.4.1.20044.31.6.3.160.1.1Columnpm251dCtrllineAccessLoopIndexread-onlycurrentIndex definition for the pm251dCtrllineAccessLoop table
1.3.6.1.4.1.20044.31.6.3.160.1.2Columnpm251dCtrllineAccessLoopPortnread-writecurrentLine Loop Back :This OID operates a loopback on the Line port.
1.3.6.1.4.1.20044.31.6.3.162Tablepm251dCtrllineSfpOnOffCtrlTablenot-accessiblecurrentList of pm251dCtrllineSfpOnOffCtrl Article
1.3.6.1.4.1.20044.31.6.3.162.1Rowpm251dCtrllineSfpOnOffCtrlEntrynot-accessiblecurrentRow definition for the pm251dCtrllineSfpOnOffCtrl table
1.3.6.1.4.1.20044.31.6.3.162.1.1Columnpm251dCtrllineSfpOnOffCtrlIndexread-onlycurrentIndex definition for the pm251dCtrllineSfpOnOffCtrl table
1.3.6.1.4.1.20044.31.6.3.162.1.2Columnpm251dCtrllineSfpOnOffCtrlPortnread-writecurrentLine SFP Optical Laser OFF :This OID switches off the Line SFP. <Help> This control defines the laser state of the line transceiver
1.3.6.1.4.1.20044.31.7Nodepm251dri
1.3.6.1.4.1.20044.31.7.1Nodepm251driTable
1.3.6.1.4.1.20044.31.7.1.1Tablepm251dRinvClientTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.31.7.1.1.1Rowpm251dRinvClientEntrynot-accessiblecurrentRow definition for the Client SFP table
1.3.6.1.4.1.20044.31.7.1.1.1.1Columnpm251dRinvClientIndexread-onlycurrentIndex for Client SFP table
1.3.6.1.4.1.20044.31.7.1.1.1.2Columnpm251dRinvSfpClientread-onlycurrentInventory for the SFP: This OID contains the inventory for the Client SFP
1.3.6.1.4.1.20044.31.7.1.2Tablepm251dRinvLineTablenot-accessiblecurrentList of the SFPs on the selected module
1.3.6.1.4.1.20044.31.7.1.2.1Rowpm251dRinvLineEntrynot-accessiblecurrentRow definition for the SFP table
1.3.6.1.4.1.20044.31.7.1.2.1.1Columnpm251dRinvLineIndexread-onlycurrentIndex for SFP table
1.3.6.1.4.1.20044.31.7.1.2.1.2Columnpm251dRinvsfpLineread-onlycurrentInventory for the SFP: This OID contains the inventory for the Line SFP
1.3.6.1.4.1.20044.31.7.2Scalarpm251dRinvReloadInventoryread-writecurrentReload the inventory: This OID triggers an inventory reload.
1.3.6.1.4.1.20044.31.7.3Scalarpm251dRinvHwPlatformread-onlycurrentHW platform description: This OID contains the description of the Hardware platform.
1.3.6.1.4.1.20044.31.7.4Scalarpm251dRinvModulePlatformread-onlycurrentModule platform description: This OID contains the description of the Module.
1.3.6.1.4.1.20044.31.7.5Scalarpm251dRinvSwPlatformread-onlycurrentSW platform description: This OID contains the description of the Software platform.
1.3.6.1.4.1.20044.31.7.6Scalarpm251dRinvGwPlatformread-onlycurrentGW platform desciption: This OID contains the description of the Gateware platform.
1.3.6.1.4.1.20044.31.8Nodepm251ddownload
1.3.6.1.4.1.20044.31.8.1Nodepm251dDwlOther
1.3.6.1.4.1.20044.31.8.1.0Nodepm251dDwlrestartProcess
1.3.6.1.4.1.20044.31.8.1.0.1Scalarpm251dDwlWarmRestartProcessedread-onlycurrentWarm Restart :This OID indicates that the PM last restart was a Warm RESTART
1.3.6.1.4.1.20044.31.8.1.0.2Scalarpm251dDwlColdRestartProcessedread-onlycurrentCold Restart :This OID indicates that the PM last restart was a Cold RESTART
1.3.6.1.4.1.20044.31.8.1.1Nodepm251dDwlswBanksUsed
1.3.6.1.4.1.20044.31.8.1.1.1Scalarpm251dDwlSwBank1Usedread-onlycurrentSW bank 1 active :This OID indicates the PM is working on SW bank 1 <Help> This status indicates if the SW bank 1 is active or standby
1.3.6.1.4.1.20044.31.8.1.1.2Scalarpm251dDwlSwBank2Usedread-onlycurrentSW bank 2 active :This OID indicates the PM is working on SW bank 2 <Help> This status indicates if the SW bank 2 is active or standby
1.3.6.1.4.1.20044.31.8.1.1.5Scalarpm251dDwlSwBank1Notemptyread-onlycurrentSW bank 1 loaded :This OID indicates a software is loaded in SW bank1 <Help> This status indicates if the SW bank 1 contains SW package
1.3.6.1.4.1.20044.31.8.1.1.6Scalarpm251dDwlSwBank2Notemptyread-onlycurrentSW bank 2 loaded :This OID indicates a software is loaded in SW bank2 <Help> This status indicates if the SW bank 2 contains SW package
1.3.6.1.4.1.20044.31.8.1.2Nodepm251dDwlgwBanksUsed
1.3.6.1.4.1.20044.31.8.1.2.1Scalarpm251dDwlGwBank1Usedread-onlycurrentGW bank 1 active :This OID indicates the PM is working on GW bank 1 <Help> This status indicates if the GW bank 1 is active or standby
1.3.6.1.4.1.20044.31.8.1.2.2Scalarpm251dDwlGwBank2Usedread-onlycurrentGW bank 2 active :This OID indicates the PM is working on GW bank 2
1.3.6.1.4.1.20044.31.8.1.2.3Scalarpm251dDwlGwBank3Usedread-onlycurrentGW bank 3 active :This OID indicates the PM is working on GW bank 3 <Help> This status indicates if the GW bank 3 is active or standby
1.3.6.1.4.1.20044.31.8.1.2.4Scalarpm251dDwlGwBank4Usedread-onlycurrentGW bank 4 active :This OID indicates the PM is working on GW bank 4
1.3.6.1.4.1.20044.31.8.1.2.5Scalarpm251dDwlGwBank1Notemptyread-onlycurrentGW bank 1 loaded :This OID indicates a gateware is loaded in GW bank1 <Help> This status indicates if the GW bank 1 contains GW package
1.3.6.1.4.1.20044.31.8.1.2.6Scalarpm251dDwlGwBank2Notemptyread-onlycurrentGW bank 2 loaded :This OID indicates a gateware is loaded in GW bank2
1.3.6.1.4.1.20044.31.8.1.2.7Scalarpm251dDwlGwBank3Notemptyread-onlycurrentGW bank 3 loaded :This OID indicates a gateware is loaded in GW bank3 <Help> This status indicates if the GW bank 3 contains GW package
1.3.6.1.4.1.20044.31.8.1.2.8Scalarpm251dDwlGwBank4Notemptyread-onlycurrentGW bank 4 loaded :This OID indicates a gateware is loaded in GW bank4
1.3.6.1.4.1.20044.31.8.2Nodepm251dDwlPort
1.3.6.1.4.1.20044.31.8.3Nodepm251dDwlLine
1.3.6.1.4.1.20044.31.9Nodepm251dConfig
1.3.6.1.4.1.20044.31.9.1Nodepm251dCfgAccessCAisCsf
1.3.6.1.4.1.20044.31.9.1.1Tablepm251dCfgClientcaiscsfTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.31.9.1.1.1Rowpm251dCfgClientcaiscsfEntrynot-accessiblecurrentRow definition for the accessCAisCsf table
1.3.6.1.4.1.20044.31.9.1.1.1.1Columnpm251dCfgClientcaiscsfIndexread-onlycurrentIndex definition for the clientcaiscsf table
1.3.6.1.4.1.20044.31.9.1.1.1.3Columnpm251dCfgCAisModePortnread-writecurrentCAIS mode on Client Port :This register enables/disables Client Port laser shutdown on CAIS insertion condition
1.3.6.1.4.1.20044.31.9.1.1.1.4Columnpm251dCfgSts24cContribPortnread-writecurrentSts24c contributors on Client Port :This register selects the contributors of STS24c to downstream CAIS/CSF on Port
1.3.6.1.4.1.20044.31.9.1.1.1.9Columnpm251dCfgUpAccessioAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the Client Port.
1.3.6.1.4.1.20044.31.9.1.1.1.10Columnpm251dCfgUpMapperDeAlmPortnread-writecurrentCSF contributors on Client Port :This register configures the contributors to upstream CSF insertion on the Client Port.
1.3.6.1.4.1.20044.31.9.1.1.1.18Columnpm251dCfgDownMapperDeAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on Client Port.
1.3.6.1.4.1.20044.31.9.1.1.1.19Columnpm251dCfgDownDfrmAlmPortnread-writecurrentCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on Client Port.
1.3.6.1.4.1.20044.31.9.1.1.1.22Columnpm251dCfgDownLineIoAlmPortnread-writedeprecatedCAIS contributors on Client Port :This register configures the contributors to downstream CAIS insertion on Client Port.
1.3.6.1.4.1.20044.31.9.2Nodepm251dCfgStartup
1.3.6.1.4.1.20044.31.9.2.1Tablepm251dCfgClientStartupTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.31.9.2.1.1Rowpm251dCfgClientStartupEntrynot-accessiblecurrentRow definition for the startup table
1.3.6.1.4.1.20044.31.9.2.1.1.1Columnpm251dCfgClientStartupIndexread-onlycurrentIndex definition for the clientStartup table
1.3.6.1.4.1.20044.31.9.2.1.1.3Columnpm251dCfgSystConfPortPortnread-writecurrentDefault Settings on Client Port :This register configures the default initialisation settings on the client port.
1.3.6.1.4.1.20044.31.9.2.1.1.4Columnpm251dCfgNetConfPortPortnread-writecurrentDefault Protocol on Client Port :This register configures the default initialisation protocol on the client port.
1.3.6.1.4.1.20044.31.9.2.1.1.6Columnpm251dCfgPortsOptionsPortnread-writedeprecatedDefault Options on Client Port :This register configures the default options on the client port
1.3.6.1.4.1.20044.31.9.2.2Nodepm251dtablelineStartup
1.3.6.1.4.1.20044.31.9.2.2.2Scalarpm251dCfgsystConfLine1read-writecurrentDefault Settings on Line 1 :This register configures the default initialisation settings on Line port 1.
1.3.6.1.4.1.20044.31.9.2.2.5Scalarpm251dCfglineOptions1read-writecurrentDefault Options on Active Line Port 1 :This register configures the default options on the active line port
1.3.6.1.4.1.20044.31.9.2.2.6Scalarpm251dCfgsystConfLine2read-writecurrentDefault Settings on Line 2 :This register configures the default initialisation settings on Line port 2.
1.3.6.1.4.1.20044.31.9.2.2.7Scalarpm251dCfglineSelectionread-writecurrentDefault Settings of active line :This register configures the start up active line.
1.3.6.1.4.1.20044.31.9.2.2.9Scalarpm251dCfglineOptions2read-writecurrentDefault Options on Active Line Port 2 :This register configures the default options on the active line port
1.3.6.1.4.1.20044.31.9.3Nodepm251dCfgLabels
1.3.6.1.4.1.20044.31.9.3.1Tablepm251dCfgLabelclientTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.31.9.3.1.1Rowpm251dCfgLabelclientEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.31.9.3.1.1.1Columnpm251dCfgLabelclientIndexread-onlycurrentIndex definition for the labelclient table
1.3.6.1.4.1.20044.31.9.3.1.1.3Columnpm251dCfgLabelclientPortnread-writecurrentDefault settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports.
1.3.6.1.4.1.20044.31.9.3.2Tablepm251dCfgLabellineTablenot-accessiblecurrentList of Article
1.3.6.1.4.1.20044.31.9.3.2.1Rowpm251dCfgLabellineEntrynot-accessiblecurrentRow definition for the labels table
1.3.6.1.4.1.20044.31.9.3.2.1.1Columnpm251dCfgLabellineIndexread-onlycurrentIndex definition for the labelline table
1.3.6.1.4.1.20044.31.9.3.2.1.3Columnpm251dCfgLabellinePortnread-writecurrentDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines.
1.3.6.1.4.1.20044.31.9.257Scalarpm251dCfgWriteConfigurationread-writecurrentWrite configuration to PM: This OID, when sets, write the complete configuration to the PM.
1.3.6.1.4.1.20044.31.10Nodepm251dtraps
1.3.6.1.4.1.20044.31.10.2Scalarpm251dTrapPortNumberread-onlycurrentLast port which generated a trap
1.3.6.1.4.1.20044.31.10.3Scalarpm251dTrapBoardNumberread-onlycurrentLast module which generated a trap
1.3.6.1.4.1.20044.31.10.4Scalarpm251dTrapLineNumberread-onlycurrentLast line which generated a trap
1.3.6.1.4.1.20044.31.10.30Notificationpm251dLineTrapNotUrgentGoesOncurrentNot urgent line default is activated
1.3.6.1.4.1.20044.31.10.31Notificationpm251dLineTrapNotUrgentGoesOffcurrentNot urgent line default disappeared
1.3.6.1.4.1.20044.31.10.32Notificationpm251dLineTrapUrgentGoesOncurrentUrgent line default is activated
1.3.6.1.4.1.20044.31.10.33Notificationpm251dLineTrapUrgentGoesOffcurrentUrgent line default disappeared
1.3.6.1.4.1.20044.31.10.34Notificationpm251dLineTrapCritGoesOncurrentCritical line default is activated
1.3.6.1.4.1.20044.31.10.35Notificationpm251dLineTrapCritGoesOffcurrentCritical line default disappeared
1.3.6.1.4.1.20044.31.10.40Notificationpm251dClientTrapNotUrgentGoesOncurrentNot urgent client default is activated
1.3.6.1.4.1.20044.31.10.41Notificationpm251dClientTrapNotUrgentGoesOffcurrentNot urgent client default disappeared
1.3.6.1.4.1.20044.31.10.42Notificationpm251dClientTrapUrgentGoesOncurrentUrgent client default is activated
1.3.6.1.4.1.20044.31.10.43Notificationpm251dClientTrapUrgentGoesOffcurrentUrgent client default disappeared
1.3.6.1.4.1.20044.31.10.44Notificationpm251dClientTrapCritGoesOncurrentCritical client default is activated
1.3.6.1.4.1.20044.31.10.45Notificationpm251dClientTrapCritGoesOffcurrentCritical client default disappeared
1.3.6.1.4.1.20044.31.11Nodepm251dMonitoring
1.3.6.1.4.1.20044.31.11.1Nodepm251dMonOther
1.3.6.1.4.1.20044.31.11.1.3Nodepm251dMonRmon
1.3.6.1.4.1.20044.31.11.2Nodepm251dMonClient
1.3.6.1.4.1.20044.31.11.2.4Nodepm251dMonClientRmonCounter