MIB Viewer

EMAP-MIB

1092 objects
EMAP MIB defines MIB objects which provides load and backup management, patch management NMS interfaces. The current version is v1.01
Imported Objects
HUAWEI-MIBhuaweiUtility
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCTEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.6.164IdentityhwSiteMonitorMIBEMAP MIB defines MIB objects which provides load and backup management, patch management NMS interfaces. The current version is v1.01
1.3.6.1.4.1.2011.6.164.1NodehwSiteMonitorMIBObjects
1.3.6.1.4.1.2011.6.164.1.1NodehwSiteInfo
1.3.6.1.4.1.2011.6.164.1.1.1NodehwSiteSummary
1.3.6.1.4.1.2011.6.164.1.1.1.1ScalarhwSiteIdread-onlycurrentSite ID, default value: 000,000.Naming rule of the site device ID (six digits): The first three digits indicate the device name and the last three digits indic…
1.3.6.1.4.1.2011.6.164.1.1.1.2ScalarhwSiteNameread-writecurrentSite name, which users can configure, is used to specify a site. Otherwise, the configured character can not be any other languages except English.
1.3.6.1.4.1.2011.6.164.1.1.1.3ScalarhwSiteAdminAddrread-writecurrentSite administrant address, which users can assigned, is the unique ID of a site. It is used for device management by NMS, and value range is 0 to 65535.
1.3.6.1.4.1.2011.6.164.1.1.1.4ScalarhwSiteDescriptionread-writecurrentSite description. It is of the character string type. It is used to describe the site information such as the site location, which users can configure. Otherwi…
1.3.6.1.4.1.2011.6.164.1.1.1.5ScalarhwNetIdentifierread-writecurrentNE ID. It is of the character string type. It is the unique ID of the site (an independent network element (NE)) on the network. Otherwise, the configured char…
1.3.6.1.4.1.2011.6.164.1.1.1.6ScalarhwSiteIpread-onlycurrentSite IP address, default value is 192.168.0.10. Users need to configure the site IP address.
1.3.6.1.4.1.2011.6.164.1.1.1.7ScalarhwSiteNetmaskread-onlycurrentSite netmask, default value is 255.255.255.0. Users need to configure the site netmask.
1.3.6.1.4.1.2011.6.164.1.1.1.8ScalarhwSiteGatewayread-onlycurrentSite gateway, default value: 192.168.0.1. Users need to configure the site gateway.
1.3.6.1.4.1.2011.6.164.1.1.1.9ScalarhwSiteDGWorkStatusread-onlycurrentState of the diesel working state. It is an enumeration type: If the enumeration value is 1, it indicates that the diesel is in the idle state; If the enumerat…
1.3.6.1.4.1.2011.6.164.1.1.1.10ScalarhwSiteRunningStatusread-onlycurrentState of the site alarm state. It is an enumeration type: If the enumeration value is 1, it indicates that the site is in the normal state; If the enumeration …
1.3.6.1.4.1.2011.6.164.1.1.1.12ScalarhwSiteSystemEsnread-onlycurrentSystem ESN Report Neteco
1.3.6.1.4.1.2011.6.164.1.1.1.13ScalarhwSiteTimeread-writecurrentSet Site date and time, YYYY-MM-DD HH:MM:SS
1.3.6.1.4.1.2011.6.164.1.1.1.14ScalarhwSiteNetecoPrimaryServerIPread-onlycurrentNeteco Primary Server IP Address
1.3.6.1.4.1.2011.6.164.1.1.1.15ScalarhwSiteNetecoBackupServerIPread-onlycurrentNeteco Backup Server IP Address
1.3.6.1.4.1.2011.6.164.1.1.1.16ScalarhwSiteNetecoPortNumberread-onlycurrentNeteco Port Number
1.3.6.1.4.1.2011.6.164.1.1.2NodehwSiteAlarms
1.3.6.1.4.1.2011.6.164.1.1.2.1ScalarhwDeviceTrapOrdinalNumberread-writecurrentSite device event trap serial number (SN) is the unique ID of the device event trap. It is used to resend and synchronize event traps. Its value range is 0 to …
1.3.6.1.4.1.2011.6.164.1.1.2.2ScalarhwAlarmTrapOrdinalNumberread-writecurrentSite alarm serial number (SN) is the unique ID of the alarm Trap. It is used to resend and synchronize alarms. Its value range is 0 to 4294967295. When the val…
1.3.6.1.4.1.2011.6.164.1.1.2.3ScalarhwAlarmQuantityread-onlycurrentAlarm number in site alarm list which are support. It is used for alarm list management by NMS, and value range is 0 to 65535.
1.3.6.1.4.1.2011.6.164.1.1.2.99TablehwSiteActiveAlarmTablenot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.1.2.99.1RowhwSiteActiveAlarmEntrynot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.1ColumnhwActiveAlarmIndexread-onlycurrentSite active alarm table index. It is the unique ID of the site alarm.
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.2ColumnhwActiveAlarmTextread-onlycurrentActive alarm name. It is of the character string type, and used to specify the content of a specific alarm.
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.3ColumnhwActiveAlarmLevelread-onlycurrentActive alarm level, which users can configure the alarm severity, is an enumeration type: If the enumeration value is 1, it indicates a critical alarm; If the …
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.4ColumnhwActiveAlarmSigDescread-onlycurrentActive alarm signal description. It is used to add and describe alarm content. Users can define the description of the alarm. Otherwise, the configured charact…
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.5ColumnhwActiveAlarmTimeread-onlycurrentActive alarm time. It is of the character string type, and used to specify the content of a specific alarm.
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.6ColumnhwSMUSiteNameread-onlycurrentSite name, which users can configure, is used to specify a site. Otherwise, the configured character can not be any other languages except English.
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.7ColumnhwSMUSiteAdminAddrread-onlycurrentSite administrant address, which users can assigned, is the unique ID of a site. It is used for device management by NMS, and value range is 0 to 65535.
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.8ColumnhwSMUNetIdentifierread-onlycurrentNE ID. It is of the character string type. It is the unique ID of the site (an independent network element (NE)) on the network. Otherwise, the configured char…
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.9ColumnhwSMUSiteDescriptionread-onlycurrentSite description. It is of the character string type. It is used to describe the site information such as the site location, which users can configure. Otherwi…
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.10ColumnhwEquipIdread-onlycurrentEquipment ID. Value range: 000,000 to 000,100, in which the first three digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.11ColumnhwEquipNameread-onlycurrentEquipment name. It is of the character string type, and users can set the name of the monitor. Otherwise, the configured character can not be any other languag…
1.3.6.1.4.1.2011.6.164.1.1.2.99.1.100ColumnhwActiveAlarmRowStatusread-createcurrentRowstatus of active alarm table.
1.3.6.1.4.1.2011.6.164.1.1.2.100TablehwSiteAlarmTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.1.2.100.1RowhwSiteAlarmEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.1.2.100.1.1ColumnhwAlarmIndexread-onlycurrentSite alarm table index. It is the unique ID of the site alarm.
1.3.6.1.4.1.2011.6.164.1.1.2.100.1.2ColumnhwAlarmTextread-onlycurrentAlarm name. It is of the character string type, and used to specify the content of a specific alarm.
1.3.6.1.4.1.2011.6.164.1.1.2.100.1.3ColumnhwAlarmLevelread-writecurrentAlarm level, which users can configure the alarm severity, is an enumeration type: If the enumeration value is 1, it indicates a critical alarm; If the enumera…
1.3.6.1.4.1.2011.6.164.1.1.2.100.1.4ColumnhwAlarmSigDescread-onlycurrentAlarm signal description. It is used to add and describe alarm content. Users can define the description of the alarm. Otherwise, the configured character can …
1.3.6.1.4.1.2011.6.164.1.1.2.100.1.100ColumnhwAlarmRowStatusread-createcurrentRowStatus of site alarms table.
1.3.6.1.4.1.2011.6.164.1.1.3NodehwSiteStatus
1.3.6.1.4.1.2011.6.164.1.1.3.1ScalarhwAcInputStatusread-onlycurrentAC fail 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.2ScalarhwRectifierStatusread-onlycurrentRectifier fault 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.3ScalarhwBatteryDischargeread-onlycurrentBattery discharge 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.4ScalarhwBatteryLowVoltageread-onlycurrentBattery low voltage 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.5ScalarhwBatteryUltraLowVoltageread-onlycurrentBattery ultra-low voltage 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.6ScalarhwBatteryDisconnectread-onlycurrentBattery disconnect 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.7ScalarhwFuseBrokenread-onlycurrentLoad fuse or battery fuse broken 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.8ScalarhwLowRecitiferCapacityread-onlycurrentlarge load current and low rectifier capacity 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.9ScalarhwBatteryTestNegativeread-onlycurrentBattery test result negative 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.10ScalarhwUrgentAlarmStatusread-onlycurrentUrgent Alarm 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.1.3.11ScalarhwNonurgentAlarmStatusread-onlycurrentNon-Urgent Alarm 0: no alarm, 1:alarm
1.3.6.1.4.1.2011.6.164.1.2NodehwSiteMonitors
1.3.6.1.4.1.2011.6.164.1.2.1NodehwMonitorsGroup
1.3.6.1.4.1.2011.6.164.1.2.1.1ScalarhwMonsGroupIdread-onlycurrentSite monitor group ID, is the unique ID of the site monitors.
1.3.6.1.4.1.2011.6.164.1.2.1.2ScalarhwMonsGroupNameread-writecurrentSite monitor group name is of the character string type, used to specify the monitor group. Users can configure it. Otherwise, the configured character can not…
1.3.6.1.4.1.2011.6.164.1.2.1.3ScalarhwMonsQuantityread-onlycurrentTotal site intelligent monitors. Units:pcs.
1.3.6.1.4.1.2011.6.164.1.2.2NodehwMonitor
1.3.6.1.4.1.2011.6.164.1.2.2.1TablehwMonitorTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.2.2.1.1RowhwMonitorEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.1ColumnhwMonIndexread-onlycurrentTable index of the site monitors (hwSiteMonitorTable) is restricted by the quantity of the site monitors (hwMonsQuantity). Value range: 1 to 100.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.2ColumnhwMonEquipIdread-onlycurrentSite monitor ID. Value range: 001,001 to 001,100, in which the first three digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.3ColumnhwMonEquipNameread-writecurrentMonitor name. It is of the character string type, and users can set the name of the monitor. Otherwise, the configured character can not be any other languages…
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.4ColumnhwMonEquipDescriptionread-writecurrentMonitor description. It is of the character string type. Users can set the description of the monitor. Otherwise, the configured character can not be any other…
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.5ColumnhwMonEquipSoftwareVersionread-onlycurrentMonitor software version. It is of the character string type.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.6ColumnhwMonEquipPcbVersionread-onlycurrentMonitor printed circuit board (PCB) hardware version. It is of the character string type.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.7ColumnhwMonEquipManufacturerread-onlycurrentMonitor manufacture. It is of the character string type, and is an inherent attribute of the device.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.8ColumnhwMonEquipManuDateread-onlycurrentMonitor production date. It is of the character string type, and is an inherent attribute of the device.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.9ColumnhwMonEquipSerialNoread-onlycurrentProduction SN of the monitor. It is the electronic tag of the products.
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.10ColumnhwMonEquipOperTotalTimeread-onlycurrentTotal monitor runtime. The monitor counts the data in real time. Value range is 0 to 65535, The value is an integer (1), Units:hours. (h). It is used for perfo…
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.11ColumnhwSetMonEquipCtrlStateread-writecurrentMonitor control status. It is an enumeration type: If the enumeration value is 1, it indicates the background control; If the enumeration value is 2, it indica…
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.12ColumnhwCtrlMonEquipResetread-writecurrentWarm-reset control of the monitor. It is an enumeration type: If the enumeration value is 1, it indicates the Warm-reset control of the monitor is normal; If t…
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.99ColumnhwMonitorOperStatusread-onlycurrentState of the site monitor module. It is an enumeration type: If the enumeration value is 1, it indicates that the site monitor module is in the normal state; I…
1.3.6.1.4.1.2011.6.164.1.2.2.1.1.100ColumnhwMonRowStatusread-createcurrentRowStatus of site monitor.
1.3.6.1.4.1.2011.6.164.1.3NodehwSiteRectifiers
1.3.6.1.4.1.2011.6.164.1.3.1NodehwRectsGroup
1.3.6.1.4.1.2011.6.164.1.3.1.1ScalarhwRectsGroupIdread-onlycurrentDevice group ID of the rectifier module. It is the unique ID of the rectifier module group, and its default value: 002,000. The first digits indicate the devic…
1.3.6.1.4.1.2011.6.164.1.3.1.2ScalarhwRectsGroupNameread-writecurrentName of the rectifier module group, character string type, is used to specify the rectifier module group. Users can configure it. Otherwise, the configured cha…
1.3.6.1.4.1.2011.6.164.1.3.1.3ScalarhwRectsTotalCurrentread-onlycurrentTotal current of the rectifier module group on the site. It indicates the real-time statistics of the rectifier module group on the site. Default value: 0 to 2…
1.3.6.1.4.1.2011.6.164.1.3.1.4ScalarhwRectsTotalQuantityread-onlycurrentTotal quantity of the rectifier modules. Value range: 0 to 256. Units:pcs.
1.3.6.1.4.1.2011.6.164.1.3.1.5ScalarhwRectsRatedVoltageread-onlycurrentRated voltage of the rectifier module group. It is an inherent attribute. Value range: 42 to 58.3, Units: V, and the value is accurate to one decimal place (.1…
1.3.6.1.4.1.2011.6.164.1.3.1.6ScalarhwModifyRectsOutputVoltageread-writecurrentVoltage adjustment of the rectifier module, which users can configure it. Value range: 41 to 59, Units: V, and the value is accurate to one decimal space (.1).…
1.3.6.1.4.1.2011.6.164.1.3.1.7ScalarhwSetRectsRedundEnableread-writecurrentSleep function of the rectifier module group on the site. It is an enumeration value: If the NMS notifies the SNMP agent that this node is set to 1, it means t…
1.3.6.1.4.1.2011.6.164.1.3.1.8ScalarhwCtrlRectsAllOnOffread-writecurrentPower-on or power-off of the rectifier module group (all the rectifier modules) on the site. It is an enumeration value: If the NMS notifies the SNMP agent tha…
1.3.6.1.4.1.2011.6.164.1.3.1.9ScalarhwRectsTotalDCPowerread-onlycurrentTotal power of the direct current output. Value range: 0 to 100000000, units: W, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indica…
1.3.6.1.4.1.2011.6.164.1.3.1.10ScalarhwRectsLoadUsageread-onlycurrentLoad Usage. Value range: 0 to 150, units: %, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.3.1.11ScalarhwRectsTotalACInputPowerread-onlycurrentTotal power of the direct current output. Value range: 0 to 100000000, units: W, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indica…
1.3.6.1.4.1.2011.6.164.1.3.1.12ScalarhwRectsHighRectifierCapacityread-writecurrentHigh rectifier capacity. Value range: 0 to 150, units: %, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is i…
1.3.6.1.4.1.2011.6.164.1.3.1.13ScalarhwRectsLowRectifierCapacityread-writecurrentLow rectifier capacity. Value range: 0 to 150, units: %, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is in…
1.3.6.1.4.1.2011.6.164.1.3.1.14ScalarhwRectsOverVoltProtThresread-writecurrentOvervoltage protection threshold. Value range: 56.0 to 60.5, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFF…
1.3.6.1.4.1.2011.6.164.1.3.2NodehwRectifier
1.3.6.1.4.1.2011.6.164.1.3.2.1TablehwRectConfigTablenot-accessiblecurrentRectifier config information table. Use this table to get rectifiers equipment ID, software version, manufacturer, rated current, efficency, AC input type, and…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1RowhwRectConfigEntrynot-accessiblecurrentRectifier config information table. Use this table to get rectifiers equipment ID, software version, manufacturer, rated current, efficency, AC input type, and…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.1ColumnhwRectConfigIndexread-onlycurrentIndex of the device configuration list for the rectifier modules, which value range: 1 to 256(To the actual subject). Lines of the device list are restricted b…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.2ColumnhwRectEquipIdread-onlycurrentRectifier module ID. Value range: 002'001 to 002'255. The first digits indicate the device type and last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.3ColumnhwRectEquipNameread-onlycurrentDevice name of the rectifier module, character string type, is used to specify the rectifier module. Users can configure it. Otherwise, the configured characte…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.4ColumnhwRectTyperead-onlycurrentSpecific type of the rectifier module. It is an enumeration type: If the enumeration value is 1, it indicates a 5A rectifier module; If the enumeration value i…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.5ColumnhwRectSoftwareVersionread-onlycurrentSoftware version of the rectifier module. It indicates the software version ID of the module.
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.6ColumnhwRectManufacturerread-onlycurrentManufacture of the rectifier module.
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.7ColumnhwRectManuDateread-onlycurrentManufacture date of rectifiers is of string type.
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.8ColumnhwRectSerialNoread-onlycurrentRectifier module SN. It indicates the electronic tag of the product.
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.9ColumnhwRectRatedCurrentread-onlycurrentRated voltage of the rectifier module, is an inherent attribute. Value range: 0 to 200, Units: A, and the value is accurate to one decimal place (.1). If the v…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.10ColumnhwRectEfficencyread-onlycurrentEfficiency of the rectifier module, is an inherent attribute. Value range: 0 to 100, Units: %, and the value is accurate to one decimal place (.1). If the valu…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.11ColumnhwRectInputAcTyperead-onlycurrentInput AC type of the rectifier module. It is an enumeration value: If the value of the node is 1, it indicates single-phase AC input; If the value of the node …
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.12ColumnhwCtrlRectOnOffread-writecurrentPower-on or power-off of the rectifier module, is an enumeration value. Users can modify the enumeration value of this node, thus controlling of the power-on o…
1.3.6.1.4.1.2011.6.164.1.3.2.1.1.100ColumnhwRectConfigRowStatusread-createcurrentRowStatus of rectifier config table.
1.3.6.1.4.1.2011.6.164.1.3.2.2TablehwRectOperTablenot-accessiblecurrentRectifier runing information table. Use this table to get rectifiers output current, output voltage, totle runing time, and current run status. This table's in…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1RowhwRectOperEntrynot-accessiblecurrentRectifier runing information table. Use this table to get rectifiers output current, output voltage, totle runing time, and current run status. This table's in…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.1ColumnhwRectOperIndexread-onlycurrentTable index of the running rectifier modules, which value range: 1 to 256(To the actual subject). Lines of the device list are restricted by the total quantity…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.2ColumnhwRectOutputCurrentread-onlycurrentOutput current of the rectifier module. It is a real-time analog parameter. Value range: 0 to 300, Units: A, and the value is accurate to one decimal place (.1…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.3ColumnhwRectOutputVoltageread-onlycurrentOutput voltage of the rectifier module. It is a real-time analog parameter. Value range: 0 to 65, Units: V, the value is accurate to one decimal place (.1). If…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.4ColumnhwRectTotalOperTimeread-onlycurrentTotal runtime of the rectifier module. Value units: minute (m), and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.5ColumnhwRectDCOutputPowerread-onlycurrentDC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inv…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.6ColumnhwRectACVoltageread-onlycurrentAC input voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates th…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.7ColumnhwRectRatedEfficiencyread-onlycurrentRated Efficiency. Value range: 0 to 100, units: %, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inva…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.8ColumnhwRectifierTemperatureread-onlycurrentRectifier Temperature. Value range: -300 to 300, units: degC, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it i…
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.99ColumnhwRectOperStatusread-onlycurrentState of the rectifier module. It is an enumeration type: If the enumeration value is 1, the rectifier module is in the normal state; If the enumeration value …
1.3.6.1.4.1.2011.6.164.1.3.2.2.1.100ColumnhwRectOperRowStatusread-createcurrentRowStatus of rectifier runing table.
1.3.6.1.4.1.2011.6.164.1.4NodehwSiteBatterys
1.3.6.1.4.1.2011.6.164.1.4.1NodehwBattsConfig
1.3.6.1.4.1.2011.6.164.1.4.1.1ScalarhwBattsGroupIdread-onlycurrentBattery group ID. It is the unique ID of the battery group device. The first digits indicate the device type and the last three digits indicate the device SN. …
1.3.6.1.4.1.2011.6.164.1.4.1.2ScalarhwBattsGroupNameread-writecurrentDevice name of the battery group. It is of the character string type, which can be configured by users. Otherwise, the configured character can not be any othe…
1.3.6.1.4.1.2011.6.164.1.4.1.3ScalarhwBattsTotalQuantityread-onlycurrentTotal quantity of battery strings, which value range: 0 to 100. Units:strings.
1.3.6.1.4.1.2011.6.164.1.4.1.4ScalarhwSetBattsHighTempActionread-writecurrentBattery high-temperature protection mode. It is an enumeration value, and can be configured. If the enumeration value is 1, it indicates the power-off protecti…
1.3.6.1.4.1.2011.6.164.1.4.1.5ScalarhwSetBattsHighTempVoltLimitread-writecurrentBattery protection voltage under high temperature. It works with the low-voltage power-off protection in battery high-temperature protection mode, which can be…
1.3.6.1.4.1.2011.6.164.1.4.1.6ScalarhwSetBattsHTDLimitread-writecurrentUpper threshold of the battery high temperature disconnection(HTD), can be configured by users. Value range: 25 to 80, Units: centigrade (degC), and the value …
1.3.6.1.4.1.2011.6.164.1.4.1.7ScalarhwSetBattsHTDEnableread-writecurrentBattery high temperature disconnection enable. It is an enumeration type: If the enumeration value is 1, enable the operation of the battery disconnection in h…
1.3.6.1.4.1.2011.6.164.1.4.1.8ScalarhwSetBattsFloatVoltageread-writecurrentFloat charge voltage of the batteries, can be configured by users. Value range: 42 to 58.3, units: V, and the value is accurate to one decimal place (.1) If th…
1.3.6.1.4.1.2011.6.164.1.4.1.9ScalarhwSetBattsBoostVoltageread-writecurrentBoostcharge voltage of the batteries, can be configured by users. Value range: 42 to 58.3, units: V, and the value is accurate to one decimal place (.1). If th…
1.3.6.1.4.1.2011.6.164.1.4.1.10ScalarhwSetBattsCurrLimitCoefficientread-writecurrentCurrent-limiting point coefficient of the batteries, can be configured by users. Value range: 0.05 to 0.5, units: C10, and the value is accurate to two decimal…
1.3.6.1.4.1.2011.6.164.1.4.1.11ScalarhwSetBattsCompFactorread-writecurrentTemperature compensated coefficient of the batteries, can be configured by user. Value range: 0 to 500, units: mv per centigrade, and the value is an integer (…
1.3.6.1.4.1.2011.6.164.1.4.1.12ScalarhwCtrlBattsBoostFloatread-writecurrentControl batteries charge mode between boost and float. It is an enumeration value. Users actively control the conversion. If the NMS notifies the SNMP agent th…
1.3.6.1.4.1.2011.6.164.1.4.1.13ScalarhwSetBattsRatedCapacityread-writecurrentSet batteries rated capacity. It is an analog parameter collected by the battery string in real time. Value range: 5 to 10000, units: Ah, the value is an integ…
1.3.6.1.4.1.2011.6.164.1.4.1.14ScalarhwSetBattsTimedBoostChargeEnabledread-writecurrentTimed Boost Charge Enabled. It is an enumeration value, and can be configured. If the enumeration value is 1, it indicates timed boost charge is disabled; If t…
1.3.6.1.4.1.2011.6.164.1.4.1.15ScalarhwSetBattsTimedBoostChargePeriodread-writecurrentTimed Boost Charge Interval. Value range: 1 to 365, units: Day, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the …
1.3.6.1.4.1.2011.6.164.1.4.1.16ScalarhwSetBattsMaxTimedBCDurationread-writecurrentMaximum Timed Boost Charge Duration. Value range: 1 to 24, units: h, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that…
1.3.6.1.4.1.2011.6.164.1.4.1.17ScalarhwSetBattsChargeOvercurAlmThresholdread-writecurrentCharge Overcurrent Alarm Threshold. Value range: 0.05 to 1, units: C10, and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFF…
1.3.6.1.4.1.2011.6.164.1.4.1.18ScalarhwSetBattsLowCapacityAlarmThresholdread-writecurrentLow Capacity Alarm Threshold. Value range: 0 to 90, units: %, and the value is an integer. (1) If the value is 2147483647(0x7FFFFFFF), it indicates that the va…
1.3.6.1.4.1.2011.6.164.1.4.2NodehwBattsOperate
1.3.6.1.4.1.2011.6.164.1.4.2.1ScalarhwBattsTotalCurrentread-onlycurrentTotal current of the battery group. It indicates the real-time statistics of the battery group on the site. Value range: -400000 to +400000, units: A, and the …
1.3.6.1.4.1.2011.6.164.1.4.2.2ScalarhwBattsPreDischargeTimeread-onlycurrentBattery group backup time. It indicates the real-time statistics of the battery group. Value range: 0 to 15360, Units: minutes (min), and the value is an integ…
1.3.6.1.4.1.2011.6.164.1.4.2.3ScalarhwBattsChargeStatusread-onlycurrentBattery charging state, indicates the charging and discharging information about the battery group. It is an enumeration type. If the enumeration value is 1, i…
1.3.6.1.4.1.2011.6.164.1.4.2.4ScalarhwBattsCurrLimitStatusread-onlycurrentBattery group current-limiting state, indicates the state information about the battery group. It is an enumeration value. If the enumeration value is 1, it in…
1.3.6.1.4.1.2011.6.164.1.4.2.5ScalarhwBattsTemprature1read-onlycurrentBattery temperature. It is a battery parameter collected in real time. Value range: -300 to 200, unit: centigrade (degC), and the value is an integer . If the …
1.3.6.1.4.1.2011.6.164.1.4.2.6ScalarhwBattsTemprature2read-onlycurrentBattery temperature. It is a battery parameter collected in real time. Value range: -50 to +100, unit: centigrade (degC), and the value is an integer (1). If t…
1.3.6.1.4.1.2011.6.164.1.4.2.7ScalarhwBattsAlarmsClearread-writecurrentBattery alarms clear. It is an enumeration type: If the enumeration value is 1, it indicates the clear batt test fail alarm ; If the enumeration value is 2, it…
1.3.6.1.4.1.2011.6.164.1.4.2.8ScalarhwBattsRatedCapacityread-onlycurrentBatteries actual capacity. It is an analog parameter collected by the battery string in real time. Value range: 0 to 2147483647, units: Ah, the value is an int…
1.3.6.1.4.1.2011.6.164.1.4.2.9ScalarhwBattsRemainCapacityread-onlycurrentRemaining capacity of all of the battery. It is an analog parameter collected by the battery string in real time. Value range: 0 to 2147483647, units: Ah, and …
1.3.6.1.4.1.2011.6.164.1.4.2.10ScalarhwTotalRemainingCapacityPercentread-onlycurrentTotal Remaining Capacity Percent. Value range: 0 to 100, units: %, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that t…
1.3.6.1.4.1.2011.6.164.1.4.2.11ScalarhwBattsTotalDischargeDepthread-onlycurrentBattery Total Discharge Depth Percent. Value range: 0 to 100, units: %, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indicates that …
1.3.6.1.4.1.2011.6.164.1.4.3NodehwBattsTest
1.3.6.1.4.1.2011.6.164.1.4.3.1ScalarhwBattsTestRecordCountread-onlycurrentBattery test records number.
1.3.6.1.4.1.2011.6.164.1.4.3.2ScalarhwSetBattsManuStdTestTimeread-writecurrentBattery standard test time, It can be configured by users, value range defines between 1 to 6000, units: minutes(min). and its value is an integer (1). Here, i…
1.3.6.1.4.1.2011.6.164.1.4.3.3ScalarhwSetBattsManuStdTestEndVoltread-writecurrentTest end voltage of single battery, which can be configured by users. value range defines between 1.7 to 2.2 Units: V/cell, and the value is accurate to two de…
1.3.6.1.4.1.2011.6.164.1.4.3.4ScalarhwSetBattsManuStdTestCellNumread-writecurrentBattery cell number in each Group, which is used in the battery standard manual test, can be configured by users. Units: psc or cell, value range defines betwe…
1.3.6.1.4.1.2011.6.164.1.4.3.5ScalarhwSetBattsManuShortTestTimeread-writecurrentBattery short test time, It can be configured by users, value range defines between 1 to 240, units: minutes(min). and its value is an integer (1). If battery …
1.3.6.1.4.1.2011.6.164.1.4.3.6ScalarhwSetBattsManuShortTestEndVoltread-writecurrentVoltage when the battery short test is ended, can be configured by users. Here, if battery manual test is standard mode, value range defines between 44.2 to 53…
1.3.6.1.4.1.2011.6.164.1.4.3.7ScalarhwCtrlBattsTestStartStopread-writecurrentBattery manualtest start and stop. It is an enumeration value. If the value is 1, it means to start a standard manual test; If the value is 2, it means to star…
1.3.6.1.4.1.2011.6.164.1.4.3.8ScalarhwSetBattsConsCurrTestEnableread-writecurrentBattery constant current test function enable or disable. It is an enumeration value. If the value is 1, it means the function is disabled; If the value is 2, …
1.3.6.1.4.1.2011.6.164.1.4.3.9ScalarhwSetBattsConsCurrTestDischCurrentread-writecurrentThe battery discharge current in the constant current test. It is an integer value(range:1A~9999A) and the value is accurate to 1A.
1.3.6.1.4.1.2011.6.164.1.4.3.10ScalarhwSetBattsTimeTestModeread-writecurrentBattery constant current test function enable or disable. It is an enumeration value. If the value is 1, it means to disable the timed test of battery; If the …
1.3.6.1.4.1.2011.6.164.1.4.3.11ScalarhwSetBattsScheduledTestPeriodread-writecurrentScheduled Test Period. Value range: 2 to 999, units: Day, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value …
1.3.6.1.4.1.2011.6.164.1.4.3.12ScalarhwSetBattsTestEndCapacityread-writecurrentTest End Capacity. Value range: 0 to 99, units: %, and the value is an integer. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.4.3.13ScalarhwSetBattsTestEndTemperatureread-writecurrentTest End Temperature. Value range: -5 to 15, units: degC, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value …
1.3.6.1.4.1.2011.6.164.1.4.3.14ScalarhwSetBattsShortTestEnableread-writecurrentBattery short test enable. It is an enumeration value, and can be configured. If the enumeration value is 1, it indicates battery short test is disabled; If th…
1.3.6.1.4.1.2011.6.164.1.4.3.15ScalarhwSetBattsShortTestPeriodread-writecurrentShort Test Period. Value range: 1 to 360, units: Day, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is i…
1.3.6.1.4.1.2011.6.164.1.4.3.100TablehwBattsTestResultTablenot-accessiblecurrentBattery test result record table. Use this table to get battery test inital time, test result, battery efficiency, battery discharge time, terminated voltage, …
1.3.6.1.4.1.2011.6.164.1.4.3.100.1RowhwBattsTestResultEntrynot-accessiblecurrentBattery test result record table. Use this table to get battery test inital time, test result, battery efficiency, battery discharge time, terminated voltage, …
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.1ColumnhwBattsTestResultIndexread-onlycurrentTable index of the battery test results. Currently up to 10 times of the battery test results are saved by default.
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.2ColumnhwBattsTestTyperead-onlycurrentRecord test type of the battery test. It is an enumeration value: If the NMS notifies the SNMP agent that this node is set to 1, it indicates a manual test; If…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.3ColumnhwBattsTestStartTimeread-onlycurrentTest start time of the record in the battery test. It is of the character string type.
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.4ColumnhwBattsTestResultread-onlycurrentBattery test result. It is an enumeration value. If the enumeration value of the node is 1, it indicates that the battery test has no result: If the enumeratio…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.5ColumnhwBattsEfficiencyread-onlycurrentBattery efficiency test. Value range: 0 to 100, Units: %, and the value is an integer (1). If the value is -1, it indicates that the test value is inefficient.…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.6ColumnhwBattsDischargeTimeread-onlycurrentDischarge time of the battery test records. Value range: 0 to 100, units: hour (h), and the value is accurate to two decimal places (.01). If the value is 2147…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.7ColumnhwBattsDischargeEndVoltageread-onlycurrentDischarge termination voltage of the battery test. Value range: 0 to 60, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.8ColumnhwBattsDischargeAvCurrentread-onlycurrentAverage discharge current of the battery test. Value range: -1000 to 1000, units: A, and the value is accurate to one decimal place (.1). If the value is 21474…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.9ColumnhwBattsDischargeAhValueread-onlycurrentDischarge ampere per hour the battery test. Value range: 0 to 5000, Units: Ah, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indi…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.10ColumnhwBattsTestTemperatureread-onlycurrentBattery temperature of the battery test termination. Value range: -50 to +100, Units: centigrade (degC), and the value is an integer (1). If the value is -1024…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.11ColumnhwBattsTestEndCourseread-onlycurrentTermination factors of the battery test. It is an enumeration value. If the enumeration value is 1, it indicates that the voltage value of the battery test rea…
1.3.6.1.4.1.2011.6.164.1.4.3.100.1.100ColumnhwBattsTestResultRowStatusread-createcurrentRowStatus of battery test table.
1.3.6.1.4.1.2011.6.164.1.4.4NodehwBattString
1.3.6.1.4.1.2011.6.164.1.4.4.1TablehwBattStringConfigTablenot-accessiblecurrentBattery string config table. Use this table to get battery string equipment ID and equipment name, to set battery standard capacity and battery install time as…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1RowhwBattStringConfigEntrynot-accessiblecurrentBattery string config table. Use this table to get battery string equipment ID and equipment name, to set battery standard capacity and battery install time as…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.1ColumnhwBattStringConfigIndexread-onlycurrentDevice table index of the battery string, value range: 1 to 100(To the actual subject).
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.2ColumnhwBattStringEquipIdread-onlycurrentBatteries device ID, can be configured by users. Value range: 003,001 to 003,100, in which the first three digits specify the device type and the last three sp…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.3ColumnhwBattStringEquipNameread-onlycurrentBatteries device name, of the character string type, is used to specify the batteries. Users can configure it. Otherwise, the configured character can not be a…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.4ColumnhwSetBattsTempUpperLimitread-writecurrentUpper threshold of the battery temperature alarm, can be configured by users. Value range: 25 to 80, Units: centigrade (degC), and the value is an integer (1).…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.5ColumnhwSetBattsTempLowerLimitread-writecurrentLower threshold of the battery temperature alarm, can be configured by users. Value range: -20 to 20, Units: centigrade (degC), and the value is an integer (1)…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.6ColumnhwSetBattsTempMeasureUpperLimitread-writecurrentUpper threshold of the battery temperature measurement, can be configured by users. Value range: 0 to 100, Units: centigrade (degC), and the value is an intege…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.7ColumnhwSetBattsTempMeasureLowerLimitread-writecurrentLower threshold of the battery temperature measurement, can be configured by users. Value range: -50 to 0, Units: centigrade (degC), and the value is an intege…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.8ColumnhwSetBattStdCapacityread-writecurrentSet battery standard capacity, is an inherent attribute of the device. Value range: 5 to 10000, units: Ah, the value is an integer (1). If the value is 2147483…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.9ColumnhwSetBattInstallTimeread-writecurrentSet battery install time, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages except E…
1.3.6.1.4.1.2011.6.164.1.4.4.1.1.100ColumnhwBattStringConfigRowStatusread-createcurrentRowStatus of battery string config table.
1.3.6.1.4.1.2011.6.164.1.4.4.2TablehwBattStringOperTablenot-accessiblecurrentBattery string runing table. Use this table to get battery string current, persent of remain capacity, battery remain capacity, battery actual capacity, as wel…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1RowhwBattStringOperEntrynot-accessiblecurrentBattery string runing table. Use this table to get battery string current, persent of remain capacity, battery remain capacity, battery actual capacity, as wel…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.1ColumnhwBattStringOperIndexread-onlycurrentDevice table index of the battery string, which value range: 1 to 100(To the actual subject).
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.2ColumnhwBattStringCurrentread-onlycurrentBatteries current. It is an analog parameter collected by the battery string in real time. Value range: -1000 to +1000, units: A, and the value is accurate to …
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.3ColumnhwBattStringRemainCapacityPercentread-onlycurrentRemaining capacity percentage of the battery string. Value range: 0 to 100, units: %, and the value is accurate to one decimal place (.1). If the value is 2147…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.4ColumnhwBattStringRemainCapacityread-onlycurrentRemaining capacity of the battery string. It is an analog parameter collected by the battery string in real time. Value range: 0 to 1000, units: Ah, and the va…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.5ColumnhwBattStringActualCapacityread-onlycurrentBatteries actual capacity. It is an analog parameter collected by the battery string in real time. Value range: 0 to 5000, units: Ah, the value is an integer (…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.6ColumnhwBattStringTempratureread-onlycurrentBattery temperature. It is a battery parameter collected in real time. Value range: -300 to +200, unit: centigrade (degC), and the value is accurate to one dec…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.7ColumnhwBattStringMidpointVoltageread-onlycurrentBatteries midpoint voltage. It is an analog parameter collected by the battery string in real time. Value range: -90 to +90, unit: V, and the value is accurate…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99ColumnhwBattStringOperStatusread-onlycurrentState of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal s…
1.3.6.1.4.1.2011.6.164.1.4.4.2.1.100ColumnhwBattStringOperRowStatusread-createcurrentRowStatus of battery string runing table.
1.3.6.1.4.1.2011.6.164.1.5NodehwSiteAcDistributions
1.3.6.1.4.1.2011.6.164.1.5.1NodehwAcDistributionsGroup
1.3.6.1.4.1.2011.6.164.1.5.1.1ScalarhwAcsGroupIdread-onlycurrentAC group ID, is the unique ID of the AC group. The first three digits indicate the device type and the last three indicate the device SN. If the last three dig…
1.3.6.1.4.1.2011.6.164.1.5.1.2ScalarhwAcsGroupNameread-writecurrentDevice name of the AC group. It is of the character string type, and can be configured by users. Otherwise, the configured character can not be any other langu…
1.3.6.1.4.1.2011.6.164.1.5.1.3ScalarhwAcsTotalCurrentread-onlycurrentTotal current of the AC group. It indicates the real-time statistics of the AC group. Value range: 0 to 1000, units: A, and the value is accurate to one decima…
1.3.6.1.4.1.2011.6.164.1.5.1.4ScalarhwAcsInputQuantityread-onlycurrentTotal quantity of the site ACUs. Value range: 0 to 100.
1.3.6.1.4.1.2011.6.164.1.5.1.5ScalarhwSetAcsUpperVoltLimitread-writecurrentUpper threshold of the AC voltage alarm, can be configured by users. Value range: 50 to 600, units: V, and the value is an integer (1). If the value is 2147483…
1.3.6.1.4.1.2011.6.164.1.5.1.6ScalarhwSetAcsLowerVoltLimitread-writecurrentLower threshold of the AC voltage alarm, can be configured by users. Value range: 50 to 600, units: V, and the value is an integer (1). If the value is 2147483…
1.3.6.1.4.1.2011.6.164.1.5.1.7ScalarhwAcsPowerConsumptionread-onlycurrentLow 32bits of AC Active power Consumption. Value range:0 to 4294967295, resolution 10wh. If GET value is 10, it means the real consumption is 10*10wh = 100wh (…
1.3.6.1.4.1.2011.6.164.1.5.1.8ScalarhwAcsPowerConsumptionHigh32bread-onlycurrentHigh 32bits of AC Active Power Consumption. Value range:0 to 4294967295, resolution 10wh.
1.3.6.1.4.1.2011.6.164.1.5.1.9ScalarhwAcsReactivePowerConsumptionread-onlycurrentLow 32bits of AC Reactive Power Consumption. Value range:0 to 4294967295, resolution 10varh. If GET value is 10, it means the real consumption is 10*10varh = 1…
1.3.6.1.4.1.2011.6.164.1.5.1.10ScalarhwAcsReactivePowerConsumptionHigh32bread-onlycurrentHigh 32bits of AC Reactive Power Consumption. Value range:0 to 4294967295, resolution 10varh.
1.3.6.1.4.1.2011.6.164.1.5.1.11ScalarhwAcsActivePowerConsumptionKwread-onlycurrentAC Active Power Consumption. Value range:0 to 4294967295, resolution 1kwh.
1.3.6.1.4.1.2011.6.164.1.5.1.12ScalarhwAcsReactivePowerConsumptionKvarread-onlycurrentAC Reactive Power Consumption. Value range:0 to 4294967295, resolution 1kwh.
1.3.6.1.4.1.2011.6.164.1.5.2NodehwAcDistribution
1.3.6.1.4.1.2011.6.164.1.5.2.1TablehwAcInputTablenot-accessiblecurrentAC input table. Use this table to get AC distribution unit ID, AC distribution unit name, A phase or AB line voltage, B phase or BC line voltage, C phase or CA…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1RowhwAcInputEntrynot-accessiblecurrentAC input table. Use this table to get AC distribution unit ID, AC distribution unit name, A phase or AB line voltage, B phase or BC line voltage, C phase or CA…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.1ColumnhwAcInputIndexread-onlycurrentACU device table index, which value range: 1 to 100. Lines of the device list are restricted by the total quantity of ACUs (hwAcsInputQuantity).
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.2ColumnhwAcEquipIdread-onlycurrentACU device ID, which users can configure. Value range: 004,001 to 004,100, in which The first digits indicate the device type and the last three digits indicat…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.3ColumnhwAcEquipNameread-writecurrentACU device name, of the character string type, is used to specify the alternating current unit (ACU). Users can configure it. Otherwise, the configured charact…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.4ColumnhwApOrAblVoltageread-onlycurrentACU A-phase or AB-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.5ColumnhwBpOrBclVoltageread-onlycurrentACU B-phase or BC-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.6ColumnhwCpOrCalVoltageread-onlycurrentACU C-phase or CA-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.7ColumnhwAphaseCurrentread-onlycurrentACU A-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 20000, units: A, and the value is accurate to one decimal p…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.8ColumnhwBphaseCurrentread-onlycurrentACU B-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 20000, units: A, and the value is accurate to one decimal p…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.9ColumnhwCphaseCurrentread-onlycurrentACU C-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 20000, units: A, and the value is accurate to one decimal p…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.10ColumnhwAcInputBreakersQuantityread-onlycurrentQuantity of the AC air circuit breakers. As the ACU lower-level subset, the node indicates the quantity of the output air circuit breakers contained by each AC…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99ColumnhwAcInputOperStatusread-onlycurrentState of the site AC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC distribution uint is in the nor…
1.3.6.1.4.1.2011.6.164.1.5.2.1.1.100ColumnhwAcRowStatusread-createcurrentRowStatus of ACU.
1.3.6.1.4.1.2011.6.164.1.5.2.2TablehwAcInputBreakerTablenot-accessiblecurrentAc input breaker table. Use this table to get AC input breaker equipment ID, AC input breaker equipment name, and AC input breaker status. This table's index i…
1.3.6.1.4.1.2011.6.164.1.5.2.2.1RowhwAcInputBreakerEntrynot-accessiblecurrentAc input breaker table. Use this table to get AC input breaker equipment ID, AC input breaker equipment name, and AC input breaker status. This table's index i…
1.3.6.1.4.1.2011.6.164.1.5.2.2.1.1ColumnhwAcInputBreakerIndexread-onlycurrentDevice table index of the AC air circuit breaker. Value range: 1 to 100. An input air circuit breaker device can be uniquely identified through the ACU table i…
1.3.6.1.4.1.2011.6.164.1.5.2.2.1.2ColumnhwAcInputBreakerEquipIdread-onlycurrentAC input air circuit breaker ID. Value range: 005,001 to 005,100. The first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.5.2.2.1.3ColumnhwAcInputBreakerEquipNameread-writecurrentAC input air circuit breaker name, of the character string type, can configured by users. Otherwise, the configured character can not be any other languages ex…
1.3.6.1.4.1.2011.6.164.1.5.2.2.1.99ColumnhwAcInputBreakerOperStatusread-onlycurrentOperation state of the site AC input breaker. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC input breaker is in the n…
1.3.6.1.4.1.2011.6.164.1.5.2.2.1.100ColumnhwAcInputBreakerRowStatusread-createcurrentRowStatus of AC input breaker.
1.3.6.1.4.1.2011.6.164.1.6NodehwSiteDcDistributions
1.3.6.1.4.1.2011.6.164.1.6.1NodehwDcDistributionsGroup
1.3.6.1.4.1.2011.6.164.1.6.1.1ScalarhwDcsGroupIdread-onlycurrentDC group ID: unique ID of the DC group. in which The first digits indicate the device type and the last three digits indicate the device SN. If the last three …
1.3.6.1.4.1.2011.6.164.1.6.1.2ScalarhwDcsGroupNameread-writecurrentDevice name of the DC group, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages excep…
1.3.6.1.4.1.2011.6.164.1.6.1.3ScalarhwDcsTotalVoltageread-onlycurrentTotal voltage of the DC group. Value range: 0 to 100, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it…
1.3.6.1.4.1.2011.6.164.1.6.1.4ScalarhwDcsTotalCurrentread-onlycurrentTotal current of the DC group. Value range: -30000 to 30000, units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFF…
1.3.6.1.4.1.2011.6.164.1.6.1.5ScalarhwDcsTotalPowerread-onlycurrentTotal power of the DC group. Value range: 0 to 3000000, units: W, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that th…
1.3.6.1.4.1.2011.6.164.1.6.1.6ScalarhwDcsTotalQuantityread-onlycurrentTotal quantity of the DC units, and its Value range: 0 to 100.
1.3.6.1.4.1.2011.6.164.1.6.1.7ScalarhwSetDcsUpperVoltLimitread-writecurrentUpper threshold of the DC voltage alarm, can be configued by users. Value range: 53 to 60, units: V, and the value is accurate to one decimal space (.1). If th…
1.3.6.1.4.1.2011.6.164.1.6.1.8ScalarhwSetDcsLowerVoltLimitread-writecurrentLower threshold of the DC voltage alarm, can be configued by users. Value range: 35 to 57, units: V, and the value is accurate to one decimal space (.1). If th…
1.3.6.1.4.1.2011.6.164.1.6.1.9ScalarhwDcsPerfoLoadConsumeread-onlycurrentPerfoLoad Consume of the DC, Value range: 0 to 429467295, units: KWh, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates tha…
1.3.6.1.4.1.2011.6.164.1.6.1.12ScalarhwDcsLoadConsumptionLow32bread-onlycurrentLow 32bits of total DC Load Consumption,Value range: 0 to 429467295, resolution 10wh. If GET value is 10, it means the real consumption is 10*10wh = 100wh (0.1…
1.3.6.1.4.1.2011.6.164.1.6.1.13ScalarhwDcsLoadConsumptionHigh32bread-onlycurrentHigh 32bits of total DC Load Consumption,Value range: 0 to 429467295, resolution 10wh.
1.3.6.1.4.1.2011.6.164.1.6.2NodehwDcDistribution
1.3.6.1.4.1.2011.6.164.1.6.2.1TablehwDcOutputTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.6.2.1.1RowhwDcOutputEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.1ColumnhwDcOutputIndexread-onlycurrentDevice table index of the DC units, which value range: 1 to 100. Lines of the device list are restricted by the total quantity of DC units (hwDcsQuantity).
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.2ColumnhwDcOutputEquipIdread-onlycurrentDC unit device ID, which value range: 006,001 to 006,100. The first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.3ColumnhwDcOutputEquipNameread-writecurrentDC unit device name, of the character string type, can be configued by users. Otherwise, the configured character can not be any other languages except English.
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.4ColumnhwDcOutputVoltageread-onlycurrentDC output voltage. It is an analog parameter collected by the DC power in real time. Value range: 0 to 100, units: V, and the value is accurate to one decimal …
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.5ColumnhwDcOutputCurrentread-onlycurrentDC output current. It is an analog parameter collected by the DC power in real time. Value range: -30000 to 30000, units: A, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.6ColumnhwDcOutputPowerread-onlycurrentDC output power. It is an analog parameter collected by the DC power in real time. Value range: 0 to 3000000, units: W, and the value is an integer (1). If the…
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.7ColumnhwLoadsQuantityread-onlycurrentQuantity of the DC load output branches, which value range: 0 to 100. As the DC unit lower-level subset, the node indicates the quantity of the DC load output …
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.8ColumnhwLoadUsageread-onlycurrentThe load usage of rated rectifier capacity. Value range: 0 to 100, units: %, and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.99ColumnhwDcOutputOperStatusread-onlycurrentState of the site DC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site DC distribution uint is in the nor…
1.3.6.1.4.1.2011.6.164.1.6.2.1.1.100ColumnhwDcOutputRowStatusread-createcurrentRowStatus of Dc output equipments.
1.3.6.1.4.1.2011.6.164.1.6.2.2TablehwLoadBranchTablenot-accessiblecurrentLoads output table. Use this table to get load branch equipment ID, load branch equipment name, load branch current, and load branch power. This table's index …
1.3.6.1.4.1.2011.6.164.1.6.2.2.1RowhwLoadBranchEntrynot-accessiblecurrentLoads output table. Use this table to get load branch equipment ID, load branch equipment name, load branch current, and load branch power. This table's index …
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.1ColumnhwLoadBranchIndexread-onlycurrentDevice table index of the DC load output branch, which value range: 1 to 100. A DC load output branch can be uniquely identified through the DC unit table inde…
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.2ColumnhwLoadBranchEquipIdread-onlycurrentDevice ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of…
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.3ColumnhwLoadBranchEquipNameread-writecurrentDevice name of the DC load output branch, of the character string type, can be configured by users. Otherwise, the configured character can not be any other la…
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.4ColumnhwLoadBranchCurrentread-onlycurrentDC load output branch current. It is an analog parameter collected by the load branch in real time. Value range: 0 to 10000, units: A, and the value is accurat…
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.5ColumnhwLoadBranchPowerread-onlycurrentDC load branch power. It is an analog parameter collected by the DC power in real time. Value range: 0 to 600000, units: W, and the value is an integer (1). If…
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.6ColumnhwLoadBranchConsumeread-onlycurrentDC load branch power consumption, Value range: 0 to 4294967295, units: KWh, and the value is accurate to one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.8ColumnhwLoadBranchConsumptionread-onlycurrentDC load branch power consumption,Value range: 0 to 4294967295, resolution:1 KWh.
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.9ColumnhwLoadBranchConsumptionLow32bread-onlycurrentLow 32 bits of DC load branch power consumption,Value range: 0 to 4294967295, resolution:10Wh
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.10ColumnhwLoadBranchConsumptionHigh32bread-onlycurrentHigh 32 bits of DC load branch power consumption,Value range: 0 to 4294967295, resolution:10Wh
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.99ColumnhwLoadBranchOperStatusread-onlycurrentState of the site load output branch. It is an enumeration type: If the enumeration value is 1, it indicates that the site load output branch is in the normal …
1.3.6.1.4.1.2011.6.164.1.6.2.2.1.100ColumnhwLoadBranchRowStatusread-createcurrentRowStatus of loads output branch.
1.3.6.1.4.1.2011.6.164.1.7NodehwLvdUnits
1.3.6.1.4.1.2011.6.164.1.7.1NodehwLvdsGroup
1.3.6.1.4.1.2011.6.164.1.7.1.1ScalarhwLvdsGroupIdread-onlycurrentLVD unit group ID. It is the unique ID of the LVD unit group. The first digits indicate the device type. The last three digits indicate the device SN. If the l…
1.3.6.1.4.1.2011.6.164.1.7.1.2ScalarhwLvdsGroupNameread-writecurrentLow-voltage power-off unit group name, of the character string type, can be configured by users. Otherwise, the configured character can not be any other langu…
1.3.6.1.4.1.2011.6.164.1.7.1.3ScalarhwLvdsTotalQuantityread-onlycurrentTotal quantity of power-off units. Value range: 0 to 100.
1.3.6.1.4.1.2011.6.164.1.7.2NodehwLvdUnit
1.3.6.1.4.1.2011.6.164.1.7.2.1TablehwLvdBranchTablenot-accessiblecurrentPower-off unit table. Use this table to get Lvd unit equipment ID and power-off unit equipment name, set power-off enable and power-off voltage, as well as con…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1RowhwLvdBranchEntrynot-accessiblecurrentPower-off unit table. Use this table to get Lvd unit equipment ID and power-off unit equipment name, set power-off enable and power-off voltage, as well as con…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.1ColumnhwLvdBranchIndexread-onlycurrentDevice table index of a power-off unit. Value range: 1 to 100. Lines of the device list are restricted by the total quantity of the power-off units (hwLvdsTota…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.2ColumnhwLvdUnitEquipIdread-onlycurrentDevice ID of a power-off unit. Value range: 8001 to 8100. The first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.3ColumnhwLvdUnitEquipNameread-onlycurrentDevice name of a power-off unit, of the character string type, is used to specify the low-voltage power-off unit. Users can configure it. Otherwise, the config…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.4ColumnhwSetLvdEnableread-writecurrentControl power-off unit enabling. It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to enable the power-off unit; I…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.5ColumnhwSetLvdVoltageread-writecurrentLow-voltage power-off voltage of a power-off unit can be configured by users. Its value range: 35 to 56, units: V, and the value is accurate to one decimal spa…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.6ColumnhwCtrlLvdread-writecurrentControl of the power-off unit. It is an enumeration value, users control it manually. If the NMS notifies the SNMP agent that the node is set to 1, it means to…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.7ColumnhwSetLvdModeread-writecurrentSelect the control mode of the power-off unit. It is an enumeration value, users can configure it manually. If the NMS notifies the SNMP agent that the node is…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.8ColumnhwSetLvdReconnectedVoltageread-writecurrentLow-voltage power-off recover of a power-off unit can be configured by users. Its value range: 37.0 to 58.0, unit: V, and the value is accurate to one decimal …
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.9ColumnhwSetLvdDisconnectedTimeread-writecurrentLow-voltage power-off disconnected time, It can be configured by users, value range defines between 5 to 1000, unit: minutes(min) �� and its value is an in…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.10ColumnhwSetLvdDisconnectedCapacityread-writecurrentPower-off unit control the power off, when Remaining capacity percentage of the battery strings is below the calue. Value range: 0 to 100, unit: %, and the val…
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.99ColumnhwLvdBranchOperStatusread-onlycurrentState of the site LVD uint. It is an enumeration type: If the enumeration value is 1, the site LVD uint is in the normal state; If the enumeration value is 2, …
1.3.6.1.4.1.2011.6.164.1.7.2.1.1.100ColumnhwLvdBranchRowStatusread-createcurrentRowStatus of lvd table.
1.3.6.1.4.1.2011.6.164.1.8NodehwSiteEnvUnits
1.3.6.1.4.1.2011.6.164.1.8.1NodehwEnvUnitsGroup
1.3.6.1.4.1.2011.6.164.1.8.1.1ScalarhwEnvUnitsGroupIdread-onlycurrentUnit group ID of the site environment. It is the unique ID of the unit group on the site. The first digits indicate the device type. The last three digits indi…
1.3.6.1.4.1.2011.6.164.1.8.1.2ScalarhwEnvUnitsGroupNameread-writecurrentUnit group name of the site environment, of the character string type, can be configured by users. Otherwise, the configured character can not be any other lan…
1.3.6.1.4.1.2011.6.164.1.8.1.3ScalarhwCtrlSmokeResetread-writecurrentSmoke sensor reset. It manually controls clearance of the smoke sensor alarm, and this node is of the enumeration type. If the enumeration value of the node is…
1.3.6.1.4.1.2011.6.164.1.8.1.4ScalarhwCtrlDoorResetread-writecurrentDoor actuator reset control. It manually controls clearance of the door actuator alarm. This node is of the enumeration type. If the enumeration value is 1, it…
1.3.6.1.4.1.2011.6.164.1.8.1.5ScalarhwCtrlBuzzerEnableread-writecurrentBuzzer enabling. It manually controls the enabling of the buzzer alarm. This node is of the enumeration type. When the enumeration value is 1, it means to enab…
1.3.6.1.4.1.2011.6.164.1.8.1.6ScalarhwEnvTempSensorsTotalQuantityread-onlycurrentQuantity of the environment temperature sensors, and its value range: 0 to 256.
1.3.6.1.4.1.2011.6.164.1.8.1.7ScalarhwEnvHumiSensorsTotalQuantityread-onlycurrentQuantity of the environment humidity sensors, and its value range: 0 to 256.
1.3.6.1.4.1.2011.6.164.1.8.1.8ScalarhwSpareDigitalsTotalQuantityread-onlycurrentQuantity of the Spare digitals, and its value range: 0 to 256.
1.3.6.1.4.1.2011.6.164.1.8.1.9ScalarhwSpareDigitalsOutputQuantityread-onlycurrentQuantity of the Spare digitals Output, and its value range: 0 to 256.
1.3.6.1.4.1.2011.6.164.1.8.2NodehwEnvSensor
1.3.6.1.4.1.2011.6.164.1.8.2.1TablehwEnvTempSensorTablenot-accessiblecurrentSite environment temperature table. Use this table to get environment temperature equipment ID, environment temperature equipment name, and environment tempera…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1RowhwEnvTempSensorEntrynot-accessiblecurrentSite environment temperature table. Use this table to get environment temperature equipment ID, environment temperature equipment name, and environment tempera…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.1ColumnhwEnvTempSensorIndexread-onlycurrentTable index of the environment temperature sensors.
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.2ColumnhwEnvTempEquipIdread-onlycurrentEnvironment temperature sensor ID.
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.3ColumnhwEnvTempEquipNameread-writecurrentEnvironment temperature sensor name, of the character string type, is used to specify an environment temperature sensor. Users can configure it. Otherwise, the…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.4ColumnhwEnvTemperatureread-onlycurrentEnvironment temperature. It is an environment parameter collected in real time. Value range: -50 to +100, units: centigrade (degC), and the value is an integer…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.5ColumnhwSetEnvTempUpperLimitread-writecurrentUpper threshold of the environment temperature alarm, can be configured by users. units: centigrade (degC), and the value is an integer (1). If the value is 21…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.6ColumnhwSetEnvTempLowerLimitread-writecurrentLower threshold of the environment temperature alarm, can be configured by users. units: centigrade (degC), and the value is an integer (1). If the value is 21…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.7ColumnhwSetEnvTempMeasureUpperLimitread-writecurrentUpper threshold of the environment temperature measurement, can be configured by users. Value range: 0 to 100, unit: centigrade (degC), and the value is an int…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.8ColumnhwSetEnvTempMeasureLowerLimitread-writecurrentLower threshold of the environment temperature measurement, can be configured by users. Value range: -50 to 0, unit: centigrade (degC), and the value is an int…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.9ColumnhwSetEnvTempAlarmEnableread-writecurrentEnvironment temperature alarm. It is an enumeration type: If the enumeration value is 1, enable the alarm of the environment temperature; If the enumeration va…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.10ColumnhwSetEnvTempUltraHighTempThresholdread-writecurrentThreshold of the environment ultra high temperature measurement, can be configured by users. unit: centigrade (degC), and the value is an integer (1). If the v…
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.99ColumnhwEnvTempSensorOperStatusread-onlycurrentState of the site environment temperature sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site environment temperature …
1.3.6.1.4.1.2011.6.164.1.8.2.1.1.100ColumnhwEnvTempSensorRowStatusread-createcurrentRowStatus of Environment temperature table.
1.3.6.1.4.1.2011.6.164.1.8.2.2TablehwEnvHumiSensorTablenot-accessiblecurrentEnvironment humidity table. Use this table to get environment humidity equipment ID , environment humidity equipment name, and environment humidity, set enviro…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1RowhwEnvHumiSensorEntrynot-accessiblecurrentEnvironment humidity table. Use this table to get environment humidity equipment ID , environment humidity equipment name, and environment humidity, set enviro…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.1ColumnhwEnvHumiSensorIndexread-onlycurrentTable index of the environment humility sensors.
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.2ColumnhwEnvHumiEquipIdread-onlycurrentEnvironment humility sensor ID
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.3ColumnhwEnvHumiEquipNameread-writecurrentEnvironment humility sensor name, of the character string type, is used to specify an environment humility sensor. Users can configure it.Otherwise, the config…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.4ColumnhwEnvHumidityread-onlycurrentEnvironment humility. It is an environment parameter collected in real time. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value i…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.5ColumnhwSetEnvHumidityUpperLimitread-writecurrentUpper threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.6ColumnhwSetEnvHumidityLowerLimitread-writecurrentLower threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.7ColumnhwSetEnvHumidityMeasureUpperLimitread-writecurrentUpper threshold of the environment humility measurement, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.8ColumnhwSetEnvHumidityMeasureLowerLimitread-writecurrentLower threshold of the environment humility measurement, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.9ColumnhwSetEnvHumiAlarmEnableread-writecurrentEnvironment humility alarm. It is an enumeration type: If the enumeration value is 1, enable the alarm of the environment humility; If the enumeration value is…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.99ColumnhwEnvHumiSensorOperStatusread-onlycurrentState of the site environment humidity sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site environment humidity sensor…
1.3.6.1.4.1.2011.6.164.1.8.2.2.1.100ColumnhwEnvHumiSensorRowStatusread-createcurrentRowStatus of Environment humidity table.
1.3.6.1.4.1.2011.6.164.1.8.2.3TablehwSpareDigitalTablenot-accessiblecurrentSpare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to se…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1RowhwSpareDigitalEntrynot-accessiblecurrentSpare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to se…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.1ColumnhwSpareDigitalIndexread-onlycurrentSpare digital table index, which value range: 1 to 256. Lines of the device list are restricted by the quantity of Spare digitals (hwSpareDigitalsTotalQuantity…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.2ColumnhwSpareDigitalEquipIdread-onlycurrentSpare digital device ID. Value range: 011'001 to 011'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.3ColumnhwSpareDigitalEquipNameread-writecurrentSpare digital name, of the character string type, is used to specify Spare digitals. Users can configure it. Otherwise, the configured character can not be any…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.4ColumnhwSpareDigitalAlarmTensionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a low-tension alarm; If the value of the node is 2, it indic…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.5ColumnhwSpareDigitalAlarmEnableread-writecurrentSpare digital alarm enabling. It is an enumeration type: If the enumeration value is 1, it means to enable the alarm; If the enumeration value is 2, it means t…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.99ColumnhwSpareDigitalOperStatusread-onlycurrentState of the site Spare digital. It is an enumeration type: If the enumeration value is 1, it indicates that the Spare digital operation state is normal; If th…
1.3.6.1.4.1.2011.6.164.1.8.2.3.1.100ColumnhwSpareDigitalRowStatusread-createcurrentRowStatus of of the site Spare digital.
1.3.6.1.4.1.2011.6.164.1.8.2.4TablehwSpareDigitalOutputTablenot-accessiblecurrentSpare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to se…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1RowhwSpareDigitalOutputEntrynot-accessiblecurrentSpare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to se…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.1ColumnhwSpareDigitalOutputIndexread-onlycurrentSpare digital table index, which value range: 1 to 256. Lines of the device list are restricted by the quantity of Spare digitals (hwSpareDigitalsTotalQuantity…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.2ColumnhwSpareDigitalOutputEquipIdread-onlycurrentSpare digital device ID. Value range: 012'001 to 012'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.3ColumnhwSpareDigitalOutputEquipNameread-writecurrentSpare digital name, of the character string type, is used to specify Spare digitals. Users can configure it. Otherwise, the configured character can not be any…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.4ColumnhwSetSpareDigitalOutputAlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a low-tension alarm; If the value of the node is 2, it indic…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.5ColumnhwSetSpareDigitalOutputEnableread-writecurrentSpare digital alarm enabling. It is an enumeration type: If the enumeration value is 1, it means to enable the alarm; If the enumeration value is 2, it means t…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.99ColumnhwSpareDigitalOutputOperStatusread-onlycurrentState of the site Spare digital. It is an enumeration type: If the enumeration value is 1, it indicates that the Spare digital operation state is normal; If th…
1.3.6.1.4.1.2011.6.164.1.8.2.4.1.100ColumnhwSpareDigitalOutputRowStatusread-createcurrentRowStatus of Spare digital device table.
1.3.6.1.4.1.2011.6.164.1.8.2.5TablehwTemp1Tablenot-accessiblecurrentTemp1 Table.
1.3.6.1.4.1.2011.6.164.1.8.2.5.1RowhwTemp1Entrynot-accessiblecurrentTemp1 Table.
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.1ColumnhwTemp1Indexread-onlycurrentTable index of the temp1 sensors. Value range: 1 to 256. Lines of the device list are restricted by the quantity of temp1 sensors (hwEnvHumiSensorsTotalQuantit…
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.2ColumnhwTemp1EquipIdread-onlycurrentTemp1 sensor ID, can be configured by users. Value range: 026'000 to 026'255, in which the first digits indicate the device type and the last three digits indi…
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.3ColumnhwTemp1EquipNameread-onlycurrentTemp1 sensor name, of the character string type, is used to specify an temp1 sensor. Users can configure it. Otherwise, the configured character can not be any…
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.4ColumnhwTemp1Valueread-onlycurrentTemp1. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.5ColumnhwTemp1HighLimitread-writecurrentUpper threshold of the temp1 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.6ColumnhwTemp1LowLimitread-writecurrentLower threshold of the temp1 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.8.2.5.1.99ColumnhwTemp1OperStatusread-onlycurrentState of the site temp1 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp1 sensor is in the normal state; If th…
1.3.6.1.4.1.2011.6.164.1.8.2.6TablehwTemp2Tablenot-accessiblecurrentTemp2 Table.
1.3.6.1.4.1.2011.6.164.1.8.2.6.1RowhwTemp2Entrynot-accessiblecurrentTemp2 Table.
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.1ColumnhwTemp2Indexread-onlycurrentTable index of the temp2 sensors. Value range: 1 to 256. Lines of the device list are restricted by the quantity of temp2 sensors (hwEnvHumiSensorsTotalQuantit…
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.2ColumnhwTemp2EquipIdread-onlycurrentTemp2 sensor ID, can be configured by users. Value range: 027'000 to 027'255, in which the first digits indicate the device type and the last three digits indi…
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.3ColumnhwTemp2EquipNameread-onlycurrentTemp2 sensor name, of the character string type, is used to specify an temp2 sensor. Users can configure it. Otherwise, the configured character can not be any…
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.4ColumnhwTemp2Valueread-onlycurrentTemp2. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.5ColumnhwTemp2HighLimitread-writecurrentUpper threshold of the temp2 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.6ColumnhwTemp2LowLimitread-writecurrentLower threshold of the temp2 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.8.2.6.1.99ColumnhwTemp2OperStatusread-onlycurrentState of the site temp2 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp2 sensor is in the normal state; If th…
1.3.6.1.4.1.2011.6.164.1.8.2.13TablehwSmokeSensorTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.13.1RowhwSmokeSensorEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.13.1.1ColumnhwSmokeSensorIndexread-onlycurrentThe tem_hum equip Index.
1.3.6.1.4.1.2011.6.164.1.8.2.13.1.2ColumnhwSmokeSensorEquipIdread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.13.1.3ColumnhwSmokeEquipNameread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.13.1.4ColumnhwSmokeSensorStatusread-onlycurrentThe smoke sensor status
1.3.6.1.4.1.2011.6.164.1.8.2.14TablehwWaterSensorTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.14.1RowhwWaterSensorEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.14.1.1ColumnhwWaterSensorIndexread-onlycurrentThe tem_hum equip Index.
1.3.6.1.4.1.2011.6.164.1.8.2.14.1.2ColumnhwWaterSensorEquipIdread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.14.1.3ColumnhwWaterEquipNameread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.14.1.4ColumnhwWaterSensorStatusread-onlycurrentThe smoke sensor status
1.3.6.1.4.1.2011.6.164.1.8.2.15TablehwDoorSensorTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.15.1RowhwDoorSensorEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.15.1.1ColumnhwDoorSensorIndexread-onlycurrentThe tem_hum equip Index.
1.3.6.1.4.1.2011.6.164.1.8.2.15.1.2ColumnhwDoorSensorEquipIdread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.15.1.3ColumnhwDoorEquipNameread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.8.2.15.1.4ColumnhwDoorSensorStatusread-onlycurrentThe smoke sensor status
1.3.6.1.4.1.2011.6.164.1.9NodehwSiteInverters
1.3.6.1.4.1.2011.6.164.1.9.1NodehwInverterGroup
1.3.6.1.4.1.2011.6.164.1.9.1.1ScalarhwInverterGroupIdread-onlycurrentInverter unit group ID. It is the unique ID of the Inverter unit group. The first digits indicate the device type. The last three digits indicate the device SN…
1.3.6.1.4.1.2011.6.164.1.9.1.2ScalarhwInverterGroupNameread-writecurrentInverter unit group name, of the character string type, can be configured by users.Otherwise, the configured character can not be any other languages except En…
1.3.6.1.4.1.2011.6.164.1.9.1.3ScalarhwInverterQuantityread-onlycurrentTotal site intelligent Inverters.
1.3.6.1.4.1.2011.6.164.1.9.2NodehwInverter
1.3.6.1.4.1.2011.6.164.1.9.2.1TablehwInverterTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.9.2.1.1RowhwInverterEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.1ColumnhwInverterIndexread-onlycurrentInverter table index,which value range:1 to 256.Lines of the device list are restricted by the quantity of Inverter.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.2ColumnhwInverterEquipIdread-onlycurrentInverter device ID. Value range: 018'001 to 018'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.3ColumnhwInverterEquipNameread-onlycurrentInverter name, of the character string type, is used to specify Inverters. Users can configure it.Otherwise, the configured character can not be any other lang…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.4ColumnhwInverterAcOutputVoltread-onlycurrentInverter AC Output voltage, Value range: 0.0 to 10000.0. Unit: V. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), …
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.5ColumnhwInverterAcOutputCurrread-onlycurrentInverter AC Output current, Value range: 0.0 to 10000.0. Unit: A. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), …
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.6ColumnhwInverterAcOutputFreqread-onlycurrentInverter AC Output frequency, Value range: 0 to 10000. Unit: Hz. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.7ColumnhwInverterAcOutputActivePowerread-onlycurrentInverter AC Output power, Value range: 0 to 10000000. Unit: W. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.8ColumnhwInverterAcOutputVAread-onlycurrentInverter AC Output power, Value range: 0.0 to 100000.0. Unit: VA. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), …
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.9ColumnhwInverterAcInputVoltread-onlycurrentInverter AC Input voltage, Value range: 0.0 to 10000.0. Unit: V. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.10ColumnhwInverterAcInputCurrread-onlycurrentInverter AC Input current, Value range: 0.0 to 10000.0. Unit: A. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.11ColumnhwInverterAcInputFreqread-onlycurrentInverter AC Input frequency, Value range: 0 to 10000. Unit: Hz. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.12ColumnhwInverterAcInputActivePowerread-onlycurrentInverter AC Input power, Value range: 0 to 10000000. Unit: W. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.13ColumnhwInverterAcInputVAread-onlycurrentInverter AC Input power, Value range: 0.0 to 10000.0. Unit: VA. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.14ColumnhwInverterDcInputVoltread-onlycurrentInverter DC Input voltage, Value range: 0.0 to 10000.0. Unit: V. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.15ColumnhwInverterDcInputCurrread-onlycurrentInverter DC Input current, Value range: 0 to 10000. Unit: A. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it in…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.16ColumnhwInverterDcInputPowerread-onlycurrentInverter DC Input power, Value range: 0 to 10000000. Unit: W. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.17ColumnhwInverterRevisionread-onlycurrentInverter software version number.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.18ColumnhwInverterPhaseNumread-onlycurrentInverter Number of the phase module, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.19ColumnhwInverterAcGroupNumread-onlycurrentInverter Number of AC group, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.20ColumnhwInverterDcGroupNumread-onlycurrentInverter Number of DC group, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.21ColumnhwInverterMajorAlarmNumread-onlycurrentInverter Number of Major alarm, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.22ColumnhwInverterMinorAlarmNumread-onlycurrentInverter Number of Minor alarm, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.23ColumnhwInverterT2SSerialNumread-onlycurrentInverter T2S serial number, Value range: 0 to 4294967295. If the value is 4294967295(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.24ColumnhwInverterModuleTempread-onlycurrentInverter module Temperature, Value range: -300 to 10000. Unit: degC. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.99ColumnhwInverterOperStatusread-onlycurrentState of the Inverter. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the normal state; If the enumeration valu…
1.3.6.1.4.1.2011.6.164.1.9.2.1.1.100ColumnhwInverterRowStatusread-onlycurrentRowStatus of Inverter table.
1.3.6.1.4.1.2011.6.164.1.10NodehwSiteCoolingDevices
1.3.6.1.4.1.2011.6.164.1.10.1NodehwCoolingDevicesGroup
1.3.6.1.4.1.2011.6.164.1.10.1.1ScalarhwCoolingDevicesEquipIdread-onlycurrentCoolingDevices unit group ID. Value range: 019'001 to 019'255, in which the first digits indicate the device type and the last three digits indicate the device…
1.3.6.1.4.1.2011.6.164.1.10.1.2ScalarhwCoolingDevicesEquipNameread-writecurrentCoolingDevices unit group name, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages ex…
1.3.6.1.4.1.2011.6.164.1.10.1.3ScalarhwCoolingDevicesModeread-writecurrentState of the CoolingDevices TC mode. It is an enumeration type: If the enumeration value is 1, it indicates that the CoolingDeviecs is in fanOnly state; If the…
1.3.6.1.4.1.2011.6.164.1.10.1.4ScalarhwCoolingDevicesHighTempAlarmTresholdread-writecurrentCoolingDevices high temp alarm tres, Value range: 25 to 80 Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates th…
1.3.6.1.4.1.2011.6.164.1.10.1.5ScalarhwCoolingDevicesHighTempAlarmClearTresholdread-writecurrentCoolingDevices high temp alarm clear tres, Value range: 25 to 80 Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indica…
1.3.6.1.4.1.2011.6.164.1.10.1.6ScalarhwCoolingDevicesExpelHidryread-writecurrentState of the CoolingDevices expel hidry. It is an enumeration type: If the enumeration value is 1, it indicates that the CoolingDeviecs is in no state; If the …
1.3.6.1.4.1.2011.6.164.1.10.2NodehwCoolingDevicesEquip
1.3.6.1.4.1.2011.6.164.1.10.2.1TablehwFanTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.10.2.1.1RowhwFanEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.1ColumnhwFanIndexread-onlycurrentFan table index,which value range: 1 to 256. Lines of the device list are restricted by the quantity of Fan.
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.2ColumnhwFanEquipIdread-onlycurrentFan device ID. Value range: 020'001 to 020'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.3ColumnhwFanEquipNameread-onlycurrentFan name, of the character string type, is used to specify Fans. Users can configure it. Otherwise, the configured character can not be any other languages exc…
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.4ColumnhwFanCtrlModeread-writecurrentState of the Fan ctrl mode. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in autoControl state; If the enumeration val…
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.5ColumnhwFan1Statusread-onlycurrentState of the Fan1 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2…
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.6ColumnhwFan2Statusread-onlycurrentState of the Fan2 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2…
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.7ColumnhwFan3Statusread-onlycurrentState of the Fan3 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2…
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.8ColumnhwFan4Statusread-onlycurrentState of the Fan4 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2…
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.9ColumnhwFan1Speedread-onlycurrentFan1 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.10ColumnhwFan2Speedread-onlycurrentFan2 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.11ColumnhwFan3Speedread-onlycurrentFan3 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.12ColumnhwFan4Speedread-onlycurrentFan4 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.99ColumnhwFanOperStatusread-onlycurrentState of the fan. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the normal state; If the enumeration value is …
1.3.6.1.4.1.2011.6.164.1.10.2.1.1.100ColumnhwFanRowStatusread-createcurrentRowStatus fo fan table.
1.3.6.1.4.1.2011.6.164.1.10.2.2TablehwDcAirConditionTablenot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.10.2.2.1RowhwDcAirConditionEntrynot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.1ColumnhwDcAirIndexread-onlycurrentDc aircondition table index
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.2ColumnhwDcAirEquipIdread-onlycurrentDc aircondition device ID.
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.3ColumnhwDcAirEquipNameread-onlycurrentDc aircondition name, of the character string type, is used to specify Fans. Users can configure it. Otherwise, the configured character can not be any other l…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.4ColumnhwDcAirCtrlModeread-writecurrentState of the Dc aircondition ctrl mode. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in autoControl state…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.5ColumnhwDcAirCtrlOnOffread-writecurrentState of the Dc aircondition control on or off. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in on state;…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.6ColumnhwDcAirRunStatusread-onlycurrentState of the Dc aircondition run status. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in standby state; I…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.7ColumnhwDcAirCompressorRunStatusread-onlycurrentState of the Dc air compressor run status. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in standby state;…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.8ColumnhwDcAirInnrFanSpeedread-onlycurrentDc aircondition innr speed, Value range: 0 to 60000. Unit: rpm, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the …
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.9ColumnhwDcAirOuterFanSpeedread-onlycurrentDc aircondition outer speed, Value range: 0.0 to 60000.0. Unit: rpm, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.10ColumnhwDcAirCompressorRunTimeread-onlycurrentDc aircondition compressor run time, Value range: 0 to 175200. Unit: h, the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that …
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.11ColumnhwDcAirRunTimeread-onlycurrentDc aircondition run time, Value range: 0 to 175200. Unit: H, the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value i…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.13ColumnhwDcAirEnterChannelTempread-onlycurrentDc aircondition enter channel temperature, Value range:-500.0 to 1000.0. Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), i…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.14ColumnhwDcAirPowerOnTempPointread-writecurrentDc aircondition power on temperature point, Value range:-200 to 800. Unit: degC. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indica…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.15ColumnhwDcAirPowerOffTempPointread-writecurrentDc aircondition power off temperature point, Value range:-200 to 800 Unit: degC. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indica…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.17ColumnhwAcOffEnergySavingread-writecurrentState of the Dc air energy saving status. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in disable state; …
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.18ColumnhwDcAirPowerOnAcOffPointread-writecurrentDc aircondition power on ac fail temperature point, Value range:-200 to 800. Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.19ColumnhwDcAirPowerOffAcOffPointread-writecurrentDc aircondition compressor start temperature point, Value range:-200 to 800. Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.21ColumnhwDcAirEquipAddressread-onlycurrentDC Air Device address And the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.99ColumnhwDcAirOperStatusread-onlycurrentState of the dc aircondition. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the standby state; If the enumerat…
1.3.6.1.4.1.2011.6.164.1.10.2.2.1.100ColumnhwDcAirRowStatusread-createcurrentRowStatus fo dc aircondition table.
1.3.6.1.4.1.2011.6.164.1.11NodehwSiteAcAmmeters
1.3.6.1.4.1.2011.6.164.1.11.2NodehwSiteAcAmmeterEquip
1.3.6.1.4.1.2011.6.164.1.11.2.1TablehwSiteAcAmmeterTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.11.2.1.1RowhwSiteAcAmmeterEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.1ColumnhwAcAmmeterIndexread-onlycurrentAc Ammeter table index,which value range:4096 to 20479. Lines of the device list are restricted by the quantity of AcAmmeter
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.2ColumnhwAcAmmeterEquipIdread-onlycurrentAc Ammeter device ID. Value range: 022'001 to 022'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.3ColumnhwAcAmmeterEquipNameread-onlycurrentAc Ammeter name, of the character string type, is used to specify Fans. Users can configure it. Otherwise, the configured character can not be any other langua…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.4ColumnhwAcAmmeterFrequencyread-onlycurrentAc Ammeter frequency, Value range: 0.00 to 1000.00. Unit: Hz. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it …
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.5ColumnhwAcAmmeterPhaseL1Voltageread-onlycurrentAc Ammeter phase a voltage, Value range: 0.00 to 2000.00. Unit: V. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF)…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.6ColumnhwAcAmmeterPhaseL2Voltageread-onlycurrentAc Ammeter phase b voltage, Value range: 0.00 to 2000.0. Unit: V. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF),…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.7ColumnhwAcAmmeterPhaseL3Voltageread-onlycurrentAc Ammeter phase c voltage, Value range: 0.00 to 2000.0. Unit: V. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF),…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.8ColumnhwAcAmmeterSetChannelNumread-writecurrentAc Ammeter set channel number, Value range: 1 to 4. Unit: NA. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the va…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.9ColumnhwAcAmmeterClearread-writecurrentAc Ammeter clear communication failure . It is an enumeration type: If the enumeration value is 1, it indicates that the ac ammeter clear communication failure…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.10ColumnhwAcAmmeterTyperead-onlycurrentAc Ammeter type, Value range: 0 to 65535. And the value is an integer(1).
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.11ColumnhwAcAmmeterVersionread-onlycurrentAc Ammeter version, of the character string type, is used to specify Ac Ammeter. Users can not configure it.
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.12ColumnhwAcAmmeterPhaseL1CurrentCH1read-onlycurrentAc Ammeter phase a current of channel 1, Value range: 0.00 to 1000.0. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.13ColumnhwAcAmmeterPhaseL2CurrentCH1read-onlycurrentAc Ammeter phase b current of channel 1, Value range: 0.00 to 1000.0. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.14ColumnhwAcAmmeterPhaseL3CurrentCH1read-onlycurrentAc Ammeter phase c current of channel 1, Value range: 0.00 to 1000.0. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.15ColumnhwAcAmmeterTotalActivePowerCH1read-onlycurrentAc Ammeter phase c current of channel 1, Value range: -1000000.00 to 1000000.00. Unit: kW. and the value is accurate to two decimal space (.01). If the value i…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.16ColumnhwAcAmmeterTotalPowerFactorCH1read-onlycurrentAc Ammeter total power factor of channel 1, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.17ColumnhwAcAmmeterTotalActiveEngryAccCH1read-onlycurrentAc Ammeter total active engry acc of channel 1, Value range: 0.00 to 1000000000.00. Unit: kWh. and the value is accurate to two decimal space (.01). If the val…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.18ColumnhwAcAmmeterPhaseL1CurrentCH2read-onlycurrentAc Ammeter phase a current of channel 2, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 214748364…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.19ColumnhwAcAmmeterPhaseL2CurrentCH2read-onlycurrentAc Ammeter phase b current of channel 2, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 214748364…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.20ColumnhwAcAmmeterPhaseL3CurrentCH2read-onlycurrentAc Ammeter phase c current of channel 2, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 214748364…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.21ColumnhwAcAmmeterTotalActivePowerCH2read-onlycurrentAc Ammeter phase c current of channel 2, Value range: -1000000.00 to 1000000.00. Unit: kW. and the value is accurate to two decimal space (.01). If the value i…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.22ColumnhwAcAmmeterTotalPowerFactorCH2read-onlycurrentAc Ammeter total power factor of channel 2, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.23ColumnhwAcAmmeterTotalActiveEngryAccCH2read-onlycurrentAc Ammeter total active engry acc of channel 2, Value range: 0.00 to 1000000000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.24ColumnhwAcAmmeterPhaseL1CurrentCH3read-onlycurrentAc Ammeter phase a current of channel 3, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 214748364…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.25ColumnhwAcAmmeterPhaseL2CurrentCH3read-onlycurrentAc Ammeter phase b current of channel 3, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 214748364…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.26ColumnhwAcAmmeterPhaseL3CurrentCH3read-onlycurrentAc Ammeter phase c current of channel 3, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 214748364…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.27ColumnhwAcAmmeterTotalActivePowerCH3read-onlycurrentAc Ammeter phase c current of channel 3, Value range: -1000000.00 to 1000000.00. Unit: kW. and the value is accurate to two decimal space (.01). If the value i…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.28ColumnhwAcAmmeterTotalPowerFactorCH3read-onlycurrentAc Ammeter total power factor of channel 3, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.29ColumnhwAcAmmeterTotalActiveEngryAccCH3read-onlycurrentAc Ammeter total active engry acc of channel 3, Value range: 0.00 to 1000000000.00. Unit: kWh. and the value is accurate to two decimal space (.01). If the val…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.30ColumnhwAcAmmeterPhaseL1CurrentCH4read-onlycurrentAc Ammeter phase a current of channel 4, Value range: 0 to 1000. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.31ColumnhwAcAmmeterPhaseL2CurrentCH4read-onlycurrentAc Ammeter phase b current of channel 4, Value range: 0 to 1000. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.32ColumnhwAcAmmeterPhaseL3CurrentCH4read-onlycurrentAc Ammeter phase c current of channel 4, Value range: 0 to 1000. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.33ColumnhwAcAmmeterTotalActivePowerCH4read-onlycurrentAc Ammeter phase c current of channel 4, Value range: -1000000 to 1000000. Unit: kW. and the value is accurate to two decimal space (.01). If the value is 2147…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.34ColumnhwAcAmmeterTotalPowerFactorCH4read-onlycurrentAc Ammeter total power factor of channel 4, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7F…
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.35ColumnhwAcAmmeterTotalActiveEngryAccCH4read-onlycurrentAc Ammeter total active engry acc of channel 4, Value range: 0 to 1000000000. Unit: kWh. and the value is accurate to two decimal space (.01). If the value is …
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.99ColumnhwAcAmmeterOperStatusread-onlycurrentState of the Ac Ammeter. It is an enumeration type: If the enumeration value is 1, it indicates that the Ac Ammeter is in the normal state; If the enumeration …
1.3.6.1.4.1.2011.6.164.1.11.2.1.1.100ColumnhwAcAmmeterRowStatusread-createcurrentRowStatus fo Ac Ammeter table.
1.3.6.1.4.1.2011.6.164.1.12NodehwSiteDG
1.3.6.1.4.1.2011.6.164.1.12.1NodehwDGGroup
1.3.6.1.4.1.2011.6.164.1.12.1.1ScalarhwDGGroupIdread-onlycurrentDevice group ID of the DG module. It is the unique ID of the DG module group, and its default value: 023,000. The first digits indicate the device type and the…
1.3.6.1.4.1.2011.6.164.1.12.1.2ScalarhwDGGroupNameread-onlycurrentName of the DG module group, character string type, is used to specify the DG module group. Otherwise, the configured character can not be any other languages …
1.3.6.1.4.1.2011.6.164.1.12.1.3ScalarhwDGAmountread-writecurrentTotal quantity of the DG modules. Value range: 0 to 2. Units:pcs.
1.3.6.1.4.1.2011.6.164.1.12.2NodehwDG
1.3.6.1.4.1.2011.6.164.1.12.2.1TablehwDGTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.12.2.1.1RowhwDGEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.1ColumnhwDGIndexread-onlycurrentDG table index,which value range:1 to 256. Lines of the device list are restricted by the quantity of DG.
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.2ColumnhwDGEquipIdread-onlycurrentDG device ID. Value range: 023'001 to 023'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.3ColumnhwDGEquipNameread-onlycurrentDevice name of the DG module, character string type, is used to specify the DG module. Otherwise, the configured character can not be any other languages excep…
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.4ColumnhwDGTyperead-onlycurrentSpecific type of the DG module. It is an enumeration type: If the enumeration value is 1, it indicates a intelligent DG module; If the enumeration value is 2, …
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.5ColumnhwDGAphaseVoltageread-onlycurrentA-phase voltage. Value range: 0 to 500, units: V, and the value is accurate to one decimal place (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.6ColumnhwDGBphaseVoltageread-onlycurrentB-phase voltage. Value range: 0 to 500, units: V, and the value is accurate to one decimal place (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.7ColumnhwDGCphaseVoltageread-onlycurrentC-phase voltage. Value range: 0 to 500, units: V, and the value is accurate to one decimal place (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.8ColumnhwDGAphaseCurrentread-onlycurrentA-phase current. Value range: 0 to 100, units: A, and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.9ColumnhwDGBphaseCurrentread-onlycurrentB-phase current. Value range: 0 to 100, units: A, and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.10ColumnhwDGCphaseCurrentread-onlycurrentC-phase current. Value range: 0 to 100, units: A, and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.11ColumnhwDGOutputPowerread-onlycurrentDG output power. Value range: 0 to 100, units: kw, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.12ColumnhwDGFrequencyread-onlycurrentThe frequency of DG. Value range: 5 to 120, units: Hz, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.13ColumnhwDGBatteryVoltageread-onlycurrentThe voltage of DG battery. Value range: 0 to 24, units: V, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.14ColumnhwDGTotalRuntimeread-onlycurrentThe total running time of DG, Value range: 0 to 876000, units: h, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.15ColumnhwDGAphasePowerFactorread-onlycurrentA phase power factor of DG, Value range: -1 to 1, units: , and the value is two decimal space (.01).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.16ColumnhwDGBphasePowerFactorread-onlycurrentB phase power factor of DG, Value range: -1 to 1, units: , and the value is two decimal space (.01).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.17ColumnhwDGCphasePowerFactorread-onlycurrentC phase power factor of DG, Value range: -1 to 1, units: , and the value is two decimal space (.01).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.18ColumnhwDGLoadRateread-onlycurrentThe load rate of DG, Value range: 0 to 100, units: %, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.19ColumnhwDGOnOffControlread-writecurrentPower-on or power-off of the DG module, is an enumeration value. Users can modify the enumeration value of this node, thus controlling of the power-on or power…
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.20ColumnhwDGFaultResetread-writecurrentDG fault reset.
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.21ColumnhwDGMaintenanceConfirmread-writecurrentDG maintenance confirm.
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.99ColumnhwDGOperStatusread-onlycurrentState of the DG. It is an enumeration type: If the enumeration value is 1, it indicates that the DG is in the normal state; If the enumeration value is 2, it i…
1.3.6.1.4.1.2011.6.164.1.12.2.1.1.100ColumnhwDGRowStatusread-createcurrentRowStatus fo DG.
1.3.6.1.4.1.2011.6.164.1.13NodehwSiteSSU
1.3.6.1.4.1.2011.6.164.1.13.1NodehwSSUGroup
1.3.6.1.4.1.2011.6.164.1.13.1.1ScalarhwSSUGroupIdread-onlycurrentDevice group ID of the SSU module. It is the unique ID of the SSU module group, and its default value: 024,000. The first digits indicate the device type and t…
1.3.6.1.4.1.2011.6.164.1.13.1.2ScalarhwSSUGroupNameread-onlycurrentName of the SSU module group, character string type, is used to specify the SSU module group. Otherwise, the configured character can not be any other language…
1.3.6.1.4.1.2011.6.164.1.13.1.3ScalarhwSSUTotalCurrentread-onlycurrentThe total output current of SSU. Value range: 0 to 1000, units: A, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.13.1.4ScalarhwSSUTotalOutputPowerread-onlycurrentThe total output current of SSU. Value range: 0 to 10000000, units: kWh, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.13.1.5ScalarhwSSUClearLostAlarmsread-writecurrentClear the lost alarm of SSU.
1.3.6.1.4.1.2011.6.164.1.13.1.6ScalarhwSSUAmountread-onlycurrentTotal quantity of the SSU modules. Value range: 0 to 100. Units:pcs.
1.3.6.1.4.1.2011.6.164.1.13.2NodehwSSU
1.3.6.1.4.1.2011.6.164.1.13.2.1TablehwSSUTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.13.2.1.1RowhwSSUEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.1ColumnhwSSUIndexread-onlycurrentSSU table index,which value range:1 to 256. Lines of the device list are restricted by the quantity of SSU.
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.2ColumnhwSSUEquipIdread-onlycurrentSSU device ID. Value range: 024'001 to 024'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.3ColumnhwSSUEquipNameread-onlycurrentDevice name of the SSU module, character string type, is used to specify the SSU module. Otherwise, the configured character can not be any other languages exc…
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.4ColumnhwSSURunningStateread-onlycurrentThe running status of the SSU module. It is an enumeration type: If the enumeration value is 1, it indicates that the SSU module is power on ; If the enumerati…
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.5ColumnhwSSUInputVoltageread-onlycurrentThe input voltage of SSU, Value range: 0 to 200, units: V, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.6ColumnhwSSUOutputVoltageread-onlycurrentThe output voltage of SSU, Value range: 0 to 200, units: V, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.7ColumnhwSSUOutputCurrentread-onlycurrentThe output current of SSU, Value range: 0 to 1000, units: A, and the value is one decimal space (.1).
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.8ColumnhwSSUAddressread-onlycurrentThe address of SSU, Value range: 0 to 100, units: , and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.13.2.1.1.100ColumnhwSSURowStatusread-createcurrentRowStatus fo SSU.
1.3.6.1.4.1.2011.6.164.1.14NodehwSiteBatteryCabinets
1.3.6.1.4.1.2011.6.164.1.14.2NodehwSiteBatteryCabinetEquip
1.3.6.1.4.1.2011.6.164.1.14.2.1TablehwSiteBatteryCabinetTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.14.2.1.1RowhwSiteBatteryCabinetEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.1ColumnhwBatteryCabinetIndexread-onlycurrentBattery Cabinet table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of Battery Cabinet
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.2ColumnhwBatteryCabinetEquipIdread-onlycurrentBattery Cabinet device ID. Value range: 025'001 to 025'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.3ColumnhwBatteryCabinetEquipNameread-onlycurrentBattery Cabinet name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be …
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.4ColumnhwBatteryCabinetIndoorVentTempread-onlycurrentIndoor vent temperature. It is an environment parameter collected in real time. Value range: -40 to +100, units: centigrade, and the value is an integer (1). I…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.5ColumnhwBatteryCabinetBattTempread-onlycurrentBattery temperature. It is an environment parameter collected in real time. Value range: -40 to +100, units: centigrade, and the value is an integer (1). If th…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.6ColumnhwBatteryCabinetFan1Speedread-onlycurrentFan 1 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured.
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.7ColumnhwBatteryCabinetFan2Speedread-onlycurrentFan 2 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured.
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.8ColumnhwBatteryCabinetFan3Speedread-onlycurrentFan 3 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured.
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.9ColumnhwBatteryCabinetFan4Speedread-onlycurrentFan 4 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured.
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.10ColumnhwBatteryCabinetAirConditionerStatusread-onlycurrentState of the airconditioner. It is an enumeration type: If the enumeration value is 1, it indicates that the airconditioner is in the standby state; If the enu…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.11ColumnhwBatteryCabinetCompressorStatusread-onlycurrentState of the compressor. It is an enumeration type: If the enumeration value is 1, it indicates that the compressor is in the standby state; If the enumeration…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.12ColumnhwBatteryCabinetInternalFanSpeedread-onlycurrentInternal Fan speed, Value range: 0 to 10000. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured.
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.13ColumnhwBatteryCabinetExternalFanSpeedread-onlycurrentExternal Fan speed, Value range: 0 to 10000. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the temperature sensor is not config…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.14ColumnhwBatteryCabinetAirConditionerRuntimeread-onlycurrentTotal runtime of the air conditioner. Value units: hour (h), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the val…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.15ColumnhwBatteryCabinetCompressorRuntimeread-onlycurrentTotal runtime of the compressor. Value units: hour (h), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.16ColumnhwBatteryCabinetAirConWorkTempread-writecurrentBattery cabinet aircondition power on temperature point, Value range:-20 to 80 Unit: degC. and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.17ColumnhwBatteryCabinetAirConStopTempread-writecurrentBattery cabinet aircondition power off temperature point, Value range:-20 to 80 Unit: degC. and the value is an integer(1).
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.99ColumnhwBatteryCabinetOperStatusread-onlycurrentState of the Battery Cabinet. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the normal state; If the enumerati…
1.3.6.1.4.1.2011.6.164.1.14.2.1.1.100ColumnhwBatteryCabinetRowStatusread-createcurrentRowStatus fo Battery Cabinet table.
1.3.6.1.4.1.2011.6.164.1.15NodehwSiteEsdu
1.3.6.1.4.1.2011.6.164.1.15.2TablehwEsduTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.15.2.1RowhwEsduEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.15.2.1.1ColumnhwEsduIndexread-onlycurrentESDU equip index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of Battery Cabinet
1.3.6.1.4.1.2011.6.164.1.15.2.1.2ColumnhwEsduEquipIdread-onlycurrentEsdu device ID. Value range: 028,001 to 028,255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.15.2.1.3ColumnhwEsduEquipNameread-onlycurrent/
1.3.6.1.4.1.2011.6.164.1.15.2.1.4ColumnhwEsduSetDigitalInput1AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.5ColumnhwEsduDigitalInput1OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.6ColumnhwEsduSetDigitalInput2AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.7ColumnhwEsduDigitalInput2OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.8ColumnhwEsduSetDigitalInput3AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.9ColumnhwEsduDigitalInput3OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.10ColumnhwEsduSetDigitalInput4AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.11ColumnhwEsduDigitalInput4OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.12ColumnhwEsduSetDigitalInput5AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.13ColumnhwEsduDigitalInput5OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.14ColumnhwEsduSetDigitalInput6AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value.If the value of the node is 1, it indicates a high-tension alarm;If the value of the node is 2, it indica…
1.3.6.1.4.1.2011.6.164.1.15.2.1.15ColumnhwEsduDigitalInput6OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.16ColumnhwEsduSetDigitalInput7AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.17ColumnhwEsduDigitalInput7OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.18ColumnhwEsduSetDigitalInput8AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.19ColumnhwEsduDigitalInput8OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.20ColumnhwEsduSetDigitalInput9AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.21ColumnhwEsduDigitalInput9OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.22ColumnhwEsduSetDigitalInput10AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.23ColumnhwEsduDigitalInput10OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.24ColumnhwEsduSetDigitalInput11AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.25ColumnhwEsduDigitalInput11OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.26ColumnhwEsduSetDigitalInput12AlarmConditionread-writecurrentSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indi…
1.3.6.1.4.1.2011.6.164.1.15.2.1.27ColumnhwEsduDigitalInput12OperStatusread-onlycurrentIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If…
1.3.6.1.4.1.2011.6.164.1.15.2.1.28ColumnhwEsduBtempValueread-onlycurrentTemp1. It is an environment parameter collected in real time. Value range: -40 to +80, Unit: degC and the value is an integer (1). If the value is -1024, it in…
1.3.6.1.4.1.2011.6.164.1.15.2.1.31ColumnhwEsduBtempOperStatusread-onlycurrentState of the site temp1 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp1 sensor is in the normal state; If th…
1.3.6.1.4.1.2011.6.164.1.15.2.1.32ColumnhwEsduTemp1Valueread-onlycurrentTemp1. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.15.2.1.33ColumnhwEsduTemp1HighLimitread-writecurrentUpper threshold of the temp1 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.15.2.1.34ColumnhwEsduTemp1LowLimitread-writecurrentLower threshold of the temp1 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.15.2.1.35ColumnhwEsduTemp1OperStatusread-onlycurrentState of the site temp1 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp1 sensor is in the normal state; If th…
1.3.6.1.4.1.2011.6.164.1.15.2.1.36ColumnhwEsduTemp2Valueread-onlycurrentTemp2. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.15.2.1.37ColumnhwEsduTemp2HighLimitread-writecurrentUpper threshold of the temp2 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value …
1.3.6.1.4.1.2011.6.164.1.15.2.1.38ColumnhwEsduTemp2LowLimitread-writecurrentLower threshold of the temp2 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.15.2.1.39ColumnhwEsduTemp2OperStatusread-onlycurrentState of the site temp2 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp2 sensor is in the normal state; If th…
1.3.6.1.4.1.2011.6.164.1.15.2.1.40ColumnhwEsduDoorSensorConnectread-writecurrentDoor Sensor Connected; It is an enumeration value, and can be configured. If the enumeration value is 1, it indicates Door Sensor is disable; If the enumeratio…
1.3.6.1.4.1.2011.6.164.1.17NodehwAcbGroupEquip
1.3.6.1.4.1.2011.6.164.1.17.1TablehwAcbGroupSampTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.17.1.1RowhwAcbGroupSampEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.17.1.1.1ColumnhwAcbGroupIndexread-onlycurrentThe battery group equip Index.
1.3.6.1.4.1.2011.6.164.1.17.1.1.2ColumnhwAcbGroupEquipIdread-onlycurrentThe battery group equip ID no.
1.3.6.1.4.1.2011.6.164.1.17.1.1.3ColumnhwAcbGroupEquipNameread-onlycurrentThe battery group equip name.
1.3.6.1.4.1.2011.6.164.1.17.1.1.4ColumnhwAcbGroupBatRunningStateread-onlycurrentState of the Battery group unit running state. It is an enumeration type: If the enumeration value is 1, it indicates the Battery is first on line, If the enum…
1.3.6.1.4.1.2011.6.164.1.17.1.1.5ColumnhwAcbGroupBatVoltread-onlycurrentThe battery volt; Value range: 0 to 100, units: V. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates th…
1.3.6.1.4.1.2011.6.164.1.17.1.1.6ColumnhwAcbGroupBatCurrread-onlycurrentThe battery current; Value range: -4000 to 4000, units: A. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indi…
1.3.6.1.4.1.2011.6.164.1.17.1.1.7ColumnhwAcbGroupTotalCapacityread-onlycurrentThe battery total capacity; Value range: 0 to 10000, units: Ah. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it…
1.3.6.1.4.1.2011.6.164.1.17.1.1.8ColumnhwAcbGroupTotalRemainCapacityread-onlycurrentThe battery total remain capacity; Value range:0 to 100, units: %. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF),…
1.3.6.1.4.1.2011.6.164.1.17.1.1.9ColumnhwAcbGroupTemperatureread-onlycurrentThe battery temperature; Value range:-50 to 100, units: degC. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it i…
1.3.6.1.4.1.2011.6.164.1.17.1.1.11ColumnhwAcbGroupBackupTimeread-onlycurrentThe battery backup time; Value range: 0 to 256, units: h. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indic…
1.3.6.1.4.1.2011.6.164.1.17.1.1.12ColumnhwAcbGroupEsmuCommNumread-onlycurrentThe esmu communicate number, Value range: 0 to 100. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.17.1.1.13ColumnhwAcbGroupBatSohread-onlycurrentThe battery soh: 0 to 100, units: %. and the value is accurate to one decimal place (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is…
1.3.6.1.4.1.2011.6.164.1.17.1.1.22ColumnhwAcbGroupTotalDischargeDepthread-onlycurrentThe battery total discharge depth, units: %. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the…
1.3.6.1.4.1.2011.6.164.1.17.2TablehwAcbGroupSetTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.17.2.1RowhwAcbGroupSetEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.17.2.1.5ColumnhwAcbGroupCellNumread-onlycurrentBattery cell number. Value range: 1 to 32, If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.17.2.1.6ColumnhwAcbGroupSetTotalCapacityread-onlycurrentThe battery total capacity, units: wh. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value…
1.3.6.1.4.1.2011.6.164.1.17.2.1.11ColumnhwAcbGroupEqualVoltread-writecurrentBattery equalcharge voltage, can be configued by users. Value range: 42 to 58, units: v, and the value is accurate to one decimal space (.1). If the value is 2…
1.3.6.1.4.1.2011.6.164.1.17.2.1.12ColumnhwAcbGroupFloatVoltread-writecurrentBattery floatcharge voltage, can be configued by users. Value range: 42 to 58, units: v, and the value is accurate to one decimal space (.1). If the value is 2…
1.3.6.1.4.1.2011.6.164.1.17.2.1.13ColumnhwAcbGroupChargeCurrLimitThrread-writecurrentBattery charge limited threhold , can be configued by users. Value range: 0.05 to 2, units: C10, and the value is accurate to two decimal space (.01). If the s…
1.3.6.1.4.1.2011.6.164.1.17.2.1.14ColumnhwAcbGroupOverCurThrread-writecurrentBattery over charge current limited threhold , can be configued by users. Value range: 0.15 to 1.2, units: C10, and the value is accurate to two decimal space …
1.3.6.1.4.1.2011.6.164.1.17.2.1.21ColumnhwAcbGroupHighTempThrread-writecurrentUpper threshold of the environment temperature alarm, can be configured by users. Value range: 35 to 70, units: centigrade (��C), and the value is an integ…
1.3.6.1.4.1.2011.6.164.1.17.2.1.22ColumnhwAcbGroupLowTempThrread-writecurrentLower threshold of the environment temperature alarm, can be configured by users. Value range: -50 to 0, units: centigrade (degC), and the value is an integer …
1.3.6.1.4.1.2011.6.164.1.17.2.1.26ColumnhwAcbGroupDodToAcidBatteryread-writecurrentThe lithium battery discharge depth for Acid Battery running; ,units: %.
1.3.6.1.4.1.2011.6.164.1.17.2.1.27ColumnhwAcbGroupDefaultChargeCurrLimitThrread-writecurrentBattery default charge limited threhold , can be configued by users. Value range: 0.05 to 2, units: C10, and the value is accurate to two decimal space (.01). …
1.3.6.1.4.1.2011.6.164.1.18NodehwAcbEquip
1.3.6.1.4.1.2011.6.164.1.18.1TablehwAcbBaseTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.18.1.1RowhwAcbBaseEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.18.1.1.1ColumnhwAcbIndexread-onlycurrentThe battery equip Index.
1.3.6.1.4.1.2011.6.164.1.18.1.1.2ColumnhwAcbEquipIdread-onlycurrentThe battery equip ID no.
1.3.6.1.4.1.2011.6.164.1.18.1.1.3ColumnhwAcbEquipNameread-writecurrentThe battery equip name.
1.3.6.1.4.1.2011.6.164.1.18.1.1.4ColumnhwAcbEquipAddrread-onlycurrentThe battery communica address.
1.3.6.1.4.1.2011.6.164.1.18.1.1.5ColumnhwAcbSoftVarread-onlycurrentThe Battery software version.
1.3.6.1.4.1.2011.6.164.1.18.2TablehwAcbSampTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.18.2.1RowhwAcbSampEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.18.2.1.1ColumnhwAcbBatVoltread-onlycurrentvoltage of the battery. It indicates the real-time statistics of the battery on the site. Value range: 0 to 60, unit: V, and the value is accurate to one decim…
1.3.6.1.4.1.2011.6.164.1.18.2.1.2ColumnhwAcbBatCurrread-onlycurrentCurrent of the battery. It indicates the real-time statistics of the battery on the site. Value range: -200 to 200, unit: A, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.3ColumnhwAcbRunningStatusread-onlycurrentBattery charging state, indicates the charging and discharging information about the battery group. It is an enumeration type. If the enumeration value is 1, i…
1.3.6.1.4.1.2011.6.164.1.18.2.1.4ColumnhwAcbBatSohread-onlycurrentSoh of the battery. It indicates the real-time statistics of the battery on the site. Value range: 0 to 100, unit: %, and the value is accurate to two decimal …
1.3.6.1.4.1.2011.6.164.1.18.2.1.5ColumnhwAcbBatCapacityread-onlycurrentCapacity of the battery. Value range: 0 to 10000, unit: Ah, and the value is accurate to two decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it ind…
1.3.6.1.4.1.2011.6.164.1.18.2.1.6ColumnhwAcbBatCell1Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.7ColumnhwAcbBatCell2Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.8ColumnhwAcbBatCell3Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.9ColumnhwAcbBatCell4Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.10ColumnhwAcbBatCell5Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.11ColumnhwAcbBatCell6Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.12ColumnhwAcbBatCell7Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.13ColumnhwAcbBatCell8Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.14ColumnhwAcbBatCell9Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.15ColumnhwAcbBatCell10Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.16ColumnhwAcbBatCell11Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.17ColumnhwAcbBatCell12Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.18ColumnhwAcbBatCell13Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.19ColumnhwAcbBatCell14Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.20ColumnhwAcbBatCell15Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.21ColumnhwAcbBatCell16Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.22ColumnhwAcbBatCell1Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.23ColumnhwAcbBatCell2Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.24ColumnhwAcbBatCell3Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.25ColumnhwAcbBatCell4Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.26ColumnhwAcbBatCell5Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.27ColumnhwAcbBatCell6Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.28ColumnhwAcbBatCell7Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.29ColumnhwAcbBatCell8Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.30ColumnhwAcbBatCell9Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.31ColumnhwAcbBatCell10Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.32ColumnhwAcbBatCell11Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.33ColumnhwAcbBatCell12Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.34ColumnhwAcbBatCell13Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.35ColumnhwAcbBatCell14Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.36ColumnhwAcbBatCell15Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.37ColumnhwAcbBatCell16Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.38ColumnhwAcbBatCell17Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.39ColumnhwAcbBatCell18Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.40ColumnhwAcbBatCell19Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.41ColumnhwAcbBatCell20Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.42ColumnhwAcbBatCell21Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.43ColumnhwAcbBatCell22Tempread-onlycurrentTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the v…
1.3.6.1.4.1.2011.6.164.1.18.2.1.44ColumnhwAcbBatCell17Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.45ColumnhwAcbBatCell18Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.46ColumnhwAcbBatCell19Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.47ColumnhwAcbBatCell20Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.48ColumnhwAcbBatCell21Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.2.1.49ColumnhwAcbBatCell22Voltread-onlycurrentVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one d…
1.3.6.1.4.1.2011.6.164.1.18.3TablehwAcbSetTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.18.3.1RowhwAcbSetEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.18.3.1.5ColumnhwAcbGyroEnableread-writecurrentGyro Function Enable, Restricted use in special areas. If the value of the device is within the range, but the setting fails, the function is not supported. It…
1.3.6.1.4.1.2011.6.164.1.18.3.1.6ColumnhwAcbGyroSensitivityLevelread-writecurrentGyro Level of Sensitivity. Restricted use in special areas. If the value of the device is within the range, but the setting fails, the function is not supporte…
1.3.6.1.4.1.2011.6.164.1.20NodehwSiteIbox
1.3.6.1.4.1.2011.6.164.1.20.1TablehwSiteIboxTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.20.1.1RowhwSiteIboxEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.20.1.1.1ColumnhwIboxIndexread-onlycurrentibox table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of ibox
1.3.6.1.4.1.2011.6.164.1.20.1.1.2ColumnhwIboxEquipIdread-onlycurrentibox device ID. Value range: 029'001 to 029'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.20.1.1.3ColumnhwIboxEquipNameread-onlycurrentIbox name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other l…
1.3.6.1.4.1.2011.6.164.1.20.1.1.4ColumnhwIbatEquipNumread-writecurrentNumber of Batteries. Value range: 0 to 96, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.21NodehwSiteIbat
1.3.6.1.4.1.2011.6.164.1.21.1TablehwSiteIbatTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.21.1.1RowhwSiteIbatEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.21.1.1.1ColumnhwIbatIndexread-onlycurrentibox table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of ibox
1.3.6.1.4.1.2011.6.164.1.21.1.1.2ColumnhwIbatEquipIdread-onlycurrentibat device ID. Value range: 030'001 to 031'537, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.21.1.1.3ColumnhwIbatEquipNameread-onlycurrentIbat name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other l…
1.3.6.1.4.1.2011.6.164.1.21.1.1.4ColumnhwIbatTemperatureread-onlycurrentIbat temperature. It is a ibat parameter collected in real time. Value range: -50 to +125, unit: centigrade (degC), and the value is an integer (1). If the val…
1.3.6.1.4.1.2011.6.164.1.21.1.1.5ColumnhwIbatVoltageread-onlycurrentIbat Voltage of the ibat. It is an inherent attribute. Value range: 0 to 100, Units: V, and the value is accurate to one decimal place (.1). If the value is 21…
1.3.6.1.4.1.2011.6.164.1.21.1.1.6ColumnhwIbatResistanceread-onlycurrentIbatResistance Value range: 0 to 1000000, units: (mohm), and the value is accurate to two decimal place (.01).
1.3.6.1.4.1.2011.6.164.1.22NodehwSiteCommExBoard
1.3.6.1.4.1.2011.6.164.1.22.1TablehwSiteCommExBoardTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.22.1.1RowhwSiteCommExBoardEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.22.1.1.1ColumnhwCommExBoardIndexread-onlycurrentCommunication Expansion Board table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of Communicat…
1.3.6.1.4.1.2011.6.164.1.22.1.1.2ColumnhwCommExBoardEquipIdread-onlycurrentCommunication Expansion Board device ID. Value range: 032,256 to 033,249, in which the first digits indicate the device type and the last three digits indicate…
1.3.6.1.4.1.2011.6.164.1.22.1.1.3ColumnhwCommExBoardEquipNameread-onlycurrentCommunication Expansion Board name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured charact…
1.3.6.1.4.1.2011.6.164.1.23NodehwSiteDGCommExBoard
1.3.6.1.4.1.2011.6.164.1.23.1TablehwSiteDGCommExBoardTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.23.1.1RowhwSiteDGCommExBoardEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.23.1.1.1ColumnhwDGCommExBoardIndexread-onlycurrentDG Communication Expansion Board table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of DG Comm…
1.3.6.1.4.1.2011.6.164.1.23.1.1.2ColumnhwDGCommExBoardEquipIdread-onlycurrentDG Communication Expansion Board device ID. Value range: 034'001, in which the first digits indicate the device type and the last three digits indicate the dev…
1.3.6.1.4.1.2011.6.164.1.23.1.1.3ColumnhwDGCommExBoardEquipNameread-onlycurrentDG Communication Expansion Board name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured char…
1.3.6.1.4.1.2011.6.164.1.27NodehwElockEquip
1.3.6.1.4.1.2011.6.164.1.27.1TablehwElockEquipTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.27.1.1RowhwElockEquipEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.27.1.1.1ColumnhwElockEquipIndexread-onlycurrentThe elock equip Index.
1.3.6.1.4.1.2011.6.164.1.27.1.1.2ColumnhwElockEquipIdread-onlycurrentThe elock equip ID no.
1.3.6.1.4.1.2011.6.164.1.27.1.1.3ColumnhwElockEquipNameread-onlycurrentThe elock equip name.
1.3.6.1.4.1.2011.6.164.1.28NodehwTemHumEquip
1.3.6.1.4.1.2011.6.164.1.28.1TablehwTemHumEquipTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.28.1.1RowhwTemHumEquipEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.1.28.1.1.1ColumnhwTemHumEquipIndexread-onlycurrentThe tem_hum equip Index.
1.3.6.1.4.1.2011.6.164.1.28.1.1.2ColumnhwTemHumEquipIdread-onlycurrentThe tem_hum equip ID no.
1.3.6.1.4.1.2011.6.164.1.28.1.1.3ColumnhwTemHumEquipNameread-onlycurrentThe tem_hum equip name.
1.3.6.1.4.1.2011.6.164.1.28.1.1.4ColumnhwTemHumEquipAmbientTempread-onlycurrentthe environment temperature. units: centigrade (degC), and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.28.1.1.5ColumnhwTemHumEquipAmbientHumidityread-onlycurrentenvironment temperature , units: %RH, and the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.28.1.1.6ColumnhwSetHumTempUpperLimitread-writecurrentUpper threshold of the environment temperature alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer …
1.3.6.1.4.1.2011.6.164.1.28.1.1.7ColumnhwSetHumTempLowerLimitread-writecurrentLower threshold of the environment temperature alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer…
1.3.6.1.4.1.2011.6.164.1.28.1.1.8ColumnhwSetHumidityUpperLimitread-writecurrentUpper threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.28.1.1.9ColumnhwSetHumidityLowerLimitread-writecurrentLower threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value…
1.3.6.1.4.1.2011.6.164.1.28.1.1.10ColumnhwTemHumEquipAddressread-onlycurrentDevice address And the value is an integer (1).
1.3.6.1.4.1.2011.6.164.1.29NodehwHeaterEquip
1.3.6.1.4.1.2011.6.164.1.29.1TablehwHeaterDeviceTablenot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.29.1.1RowhwHeaterDeviceEntrynot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.29.1.1.1ColumnhwHeaterDeviceIndexread-onlycurrentheater device table index.
1.3.6.1.4.1.2011.6.164.1.29.1.1.2ColumnhwHeaterDeviceEquipIdread-onlycurrentheater device equipid.
1.3.6.1.4.1.2011.6.164.1.29.1.1.3ColumnhwHeaterDeviceEquipNameread-onlycurrentheater device equipname.
1.3.6.1.4.1.2011.6.164.1.29.1.1.4ColumnhwHeaterStartTemperatureread-writecurrentheater start temperature; Value range:-10 to 15.Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the valu…
1.3.6.1.4.1.2011.6.164.1.29.1.1.5ColumnhwHeaterStopTemperatureread-writecurrentheater stop temperature; Value range: 5 to 20.Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value …
1.3.6.1.4.1.2011.6.164.1.31NodehwSiteDMU
1.3.6.1.4.1.2011.6.164.1.31.1TablehwSiteDMUSampTablenot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.31.1.1RowhwSiteDMUSampEntrynot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.31.1.1.1ColumnhwDMUIndexread-onlycurrentDMU table index, which value range:1 to 256. Lines of the device list are restricted by the quantity of DMU.
1.3.6.1.4.1.2011.6.164.1.31.1.1.2ColumnhwDMUEquipIdread-onlycurrentDMU device ID. Value range: 033'001 to 033'255, in which the first digits indicate the device type and the last three digits indicate the device SN.
1.3.6.1.4.1.2011.6.164.1.31.1.1.3ColumnhwDMUEquipNameread-onlycurrentDevice name of the DMU module, character string type, is used to specify the DMU module. Otherwise, the configured character can not be any other languages exc…
1.3.6.1.4.1.2011.6.164.1.31.1.1.4ColumnhwDMUDCOutputVoltageread-onlycurrentDC output voltage: 0 to 100, units: V, and the value is one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.31.1.1.5ColumnhwDMULoadCurrentread-onlycurrentLoad current: 0 to 30000, units: A, and the value is one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid.
1.3.6.1.4.1.2011.6.164.1.31.1.1.6ColumnhwDMUTotalLoadConsumptionread-onlycurrentTotal load consumption: 0 to 4294967295, units: kWh, and the value is one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the val…
1.3.6.1.4.1.2011.6.164.1.31.2TablehwSiteDMUSetTablenot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.31.2.1RowhwSiteDMUSetEntrynot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.31.2.1.1ColumnhwSiteDMULoad1LvdEnread-writecurrentload1 lvd enable :It is an enumeration type: If the enumeration value is 1, it means to disable the lvd control; If the enumeration value is 2, it means to ena…
1.3.6.1.4.1.2011.6.164.1.31.2.1.2ColumnhwSiteDMULoad1LvdModeread-writecurrentload1 lvd mode :It is an enumeration type: If the enumeration value is 1, it means the voltage mode; If the enumeration value is 2, it means the time mode
1.3.6.1.4.1.2011.6.164.1.31.2.1.3ColumnhwSiteDMULoad1LvdVoltageread-writecurrentLow-voltage power-off voltage of the DMU unit can be configured by users. Its value range: 36 to 56, units: V, and the value is accurate to one decimal space (…
1.3.6.1.4.1.2011.6.164.1.31.2.1.4ColumnhwSiteDMULoad1LvdReconVoltageread-writecurrentLow-voltage power-off recover of the DMU unit can be configured by users. Its value range: 37.0 to 58.0, unit: V, and the value is accurate to one decimal spac…
1.3.6.1.4.1.2011.6.164.1.31.2.1.5ColumnhwSiteDMULoad1LvdTimeread-writecurrentLow-voltage power-off disconnected time, It can be configured by users, and its value is an integer (1). Here, if lvd mode is time mode, value range defines be…
1.3.6.1.4.1.2011.6.164.1.31.2.1.6ColumnhwSiteDMULoad1LvdCapacityread-writecurrentPower-off unit control the power off, when Remaining capacity percentage of the battery strings is below the calue. Value range: 0 to 99, unit: %, and the valu…
1.3.6.1.4.1.2011.6.164.1.31.2.1.7ColumnhwSiteDMULoad2LvdEnread-writecurrentload1 lvd enable :It is an enumeration type: If the enumeration value is 1, it means to disable the lvd control; If the enumeration value is 2, it means to ena…
1.3.6.1.4.1.2011.6.164.1.31.2.1.8ColumnhwSiteDMULoad2LvdModeread-writecurrentload1 lvd mode :It is an enumeration type: If the enumeration value is 1, it means the voltage mode; If the enumeration value is 2, it means the time mode
1.3.6.1.4.1.2011.6.164.1.31.2.1.9ColumnhwSiteDMULoad2LvdVoltageread-writecurrentLow-voltage power-off voltage of the DMU unit can be configured by users. Its value range: 36 to 56, units: V, and the value is accurate to one decimal space (…
1.3.6.1.4.1.2011.6.164.1.31.2.1.10ColumnhwSiteDMULoad2LvdReconVoltageread-writecurrentLow-voltage power-off recover of the DMU unit can be configured by users. Its value range: 37.0 to 58.0, unit: V, and the value is accurate to one decimal spac…
1.3.6.1.4.1.2011.6.164.1.31.2.1.11ColumnhwSiteDMULoad2LvdTimeread-writecurrentLow-voltage power-off disconnected time, It can be configured by users, and its value is an integer (1). Here, if lvd mode is time mode, value range defines be…
1.3.6.1.4.1.2011.6.164.1.31.2.1.12ColumnhwSiteDMULoad2LvdCapacityread-writecurrentPower-off unit control the power off, when Remaining capacity percentage of the battery strings is below the calue. Value range: 0 to 99, unit: %, and the valu…
1.3.6.1.4.1.2011.6.164.1.33NodehwSiteAts
1.3.6.1.4.1.2011.6.164.1.33.1TablehwAtsSampTablenot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.33.1.1RowhwAtsSampEntrynot-accessiblecurrent
1.3.6.1.4.1.2011.6.164.1.33.1.1.1ColumnhwAtsIndexread-onlycurrentTable index of the running ATS modules
1.3.6.1.4.1.2011.6.164.1.33.1.1.2ColumnhwAtsEquipIdread-onlycurrentATS module ID.
1.3.6.1.4.1.2011.6.164.1.33.1.1.3ColumnhwAtsEquipNameread-onlycurrentDevice name of the ATS module
1.3.6.1.4.1.2011.6.164.2NodehwSiteMonitorMIBTraps
1.3.6.1.4.1.2011.6.164.2.1NodehwSiteAlarmTraps
1.3.6.1.4.1.2011.6.164.2.1.0NodehwSiteAlarmTrapsPrefix
1.3.6.1.4.1.2011.6.164.2.1.0.1NotificationhwRectifierFaultAlarmTrapscurrentWhen rectifiers fault alarms happen, a alarm trap will be send. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Al…
1.3.6.1.4.1.2011.6.164.2.1.0.2NotificationhwRectifierFaultAlarmResumeTrapscurrentRectifier Fault alarm resolved.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm por…
1.3.6.1.4.1.2011.6.164.2.1.0.3NotificationhwRectifierAbnormalAlarmTrapscurrentRectifier abnormal alarm, because of communication failure, module protection, or turnoff. Its correlation binding parameters: Site ID, Site name, Site descrip…
1.3.6.1.4.1.2011.6.164.2.1.0.4NotificationhwRectifierAbnormalAlarmResumeTrapscurrentRectifier abnormal alarm resume. Description.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descript…
1.3.6.1.4.1.2011.6.164.2.1.0.5NotificationhwBattLoopBreakAlarmTrapscurrentBattery loop disconnect. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port desc…
1.3.6.1.4.1.2011.6.164.2.1.0.6NotificationhwBattLoopBreakAlarmResumeTrapscurrentBattery loop break alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm p…
1.3.6.1.4.1.2011.6.164.2.1.0.7NotificationhwBattLvdAlarmTrapscurrentBattery disconnect for low voltage. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar…
1.3.6.1.4.1.2011.6.164.2.1.0.8NotificationhwBattLvdAlarmResumeTrapscurrentBattery LVD alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port des…
1.3.6.1.4.1.2011.6.164.2.1.0.9NotificationhwBattOverCurrAlarmTrapscurrentBatterys charge in over current. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm p…
1.3.6.1.4.1.2011.6.164.2.1.0.10NotificationhwBattOverCurrAlarmResumeTrapscurrentBatterys over current alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar…
1.3.6.1.4.1.2011.6.164.2.1.0.11NotificationhwBattStringTempAlarmTrapscurrentBattery string temperature is too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single de…
1.3.6.1.4.1.2011.6.164.2.1.0.12NotificationhwBattStringTempAlarmResumeTrapscurrentBattery string temperature alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description,…
1.3.6.1.4.1.2011.6.164.2.1.0.13NotificationhwBattDischargeAlarmTrapscurrentBattery group discharge alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm por…
1.3.6.1.4.1.2011.6.164.2.1.0.14NotificationhwBattDischargeAlarmResumeTrapscurrentBattery group discharge alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Al…
1.3.6.1.4.1.2011.6.164.2.1.0.15NotificationhwAcInputAlarmTrapscurrentAC absent or AC power off alarms happened. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descriptio…
1.3.6.1.4.1.2011.6.164.2.1.0.16NotificationhwAcInputAlarmResumeTrapscurrentAC input alarm resumed. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr…
1.3.6.1.4.1.2011.6.164.2.1.0.17NotificationhwAcVoltAlarmTrapscurrentAC voltage too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm po…
1.3.6.1.4.1.2011.6.164.2.1.0.18NotificationhwAcVoltAlarmResumeTrapscurrentAC voltage alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port desc…
1.3.6.1.4.1.2011.6.164.2.1.0.19NotificationhwDcVoltAlarmTrapscurrentDC voltage alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description…
1.3.6.1.4.1.2011.6.164.2.1.0.20NotificationhwDcVoltAlarmResumeTrapscurrentDC voltage alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port desc…
1.3.6.1.4.1.2011.6.164.2.1.0.21NotificationhwLoadLvdAlarmTrapscurrentLoads disconnect for low voltage. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm …
1.3.6.1.4.1.2011.6.164.2.1.0.22NotificationhwLoadLvdAlarmResumeTrapscurrentLoad LVD alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descri…
1.3.6.1.4.1.2011.6.164.2.1.0.23NotificationhwLoadFuseAlarmTrapscurrentLoad fuse broken down. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descri…
1.3.6.1.4.1.2011.6.164.2.1.0.24NotificationhwLoadFuseAlarmResumeTrapscurrentLoad fuse alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr…
1.3.6.1.4.1.2011.6.164.2.1.0.25NotificationhwEnvTempAlarmTrapscurrentEnvironment temperature is too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descr…
1.3.6.1.4.1.2011.6.164.2.1.0.26NotificationhwEnvTempAlarmResumeTrapscurrentEnvironment temperature alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Al…
1.3.6.1.4.1.2011.6.164.2.1.0.27NotificationhwEnvHumiAlarmTrapscurrentEnvironment humidity is too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descript…
1.3.6.1.4.1.2011.6.164.2.1.0.28NotificationhwEnvHumiAlarmResumeTrapscurrentEnvironment humidity alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm…
1.3.6.1.4.1.2011.6.164.2.1.0.29NotificationhwSpareDigitalAlarmTrapscurrentSpare digital fault. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descript…
1.3.6.1.4.1.2011.6.164.2.1.0.30NotificationhwSpareDigitalAlarmResumeTrapscurrentSpare digital alarm resume.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port de…
1.3.6.1.4.1.2011.6.164.2.1.0.31NotificationhwDoorAlarmTrapscurrentDoor open. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm…
1.3.6.1.4.1.2011.6.164.2.1.0.32NotificationhwDoorAlarmResumeTrapscurrentDoor alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descriptio…
1.3.6.1.4.1.2011.6.164.2.1.0.33NotificationhwWaterAlarmTrapscurrentWater alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Ala…
1.3.6.1.4.1.2011.6.164.2.1.0.34NotificationhwWaterAlarmResumeTrapscurrentWater alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descripti…
1.3.6.1.4.1.2011.6.164.2.1.0.35NotificationhwSmokeAlarmTrapscurrentSite is on fire, which is detected by smoke sensors. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single …
1.3.6.1.4.1.2011.6.164.2.1.0.36NotificationhwSmokeAlarmResumeTrapscurrentSmoke alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descripti…
1.3.6.1.4.1.2011.6.164.2.1.0.37NotificationhwWireAlarmTrapscurrentWire alarm.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm…
1.3.6.1.4.1.2011.6.164.2.1.0.38NotificationhwWireAlarmResumeTrapscurrentWire alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descriptio…
1.3.6.1.4.1.2011.6.164.2.1.0.39NotificationhwAcBreakerAlarmTrapscurrentAC breaker alarm.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description,…
1.3.6.1.4.1.2011.6.164.2.1.0.40NotificationhwAcBreakerAlarmResumeTrapscurrentAC breaker alarm resume.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr…
1.3.6.1.4.1.2011.6.164.2.1.0.41NotificationhwMultiRectFailureAlarmTrapscurrentMore than one rectifier reported fault alarms in the same time. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Al…
1.3.6.1.4.1.2011.6.164.2.1.0.42NotificationhwMultiRectFailureAlarmResumeTrapscurrentMulti-rectifiers fault alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Ala…
1.3.6.1.4.1.2011.6.164.2.1.0.43NotificationhwRectRedundAlarmTrapscurrentRectifiers work redundantly, in this case that some of rectifiers will going to sleep. Its correlation binding parameters: Site ID, Site name, Site description…
1.3.6.1.4.1.2011.6.164.2.1.0.44NotificationhwRectRedundAlarmResumeTrapscurrentRectifiers redundant alarm resume, when the power supply and requirement were in balance. Its correlation binding parameters: Site ID, Site name, Site descript…
1.3.6.1.4.1.2011.6.164.2.1.0.45NotificationhwBattUnbalanceAlarmTrapscurrentBattery works in unbalance state. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm …
1.3.6.1.4.1.2011.6.164.2.1.0.46NotificationhwBattUnbalanceAlarmResumeTrapscurrentBattery unbalance alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm po…
1.3.6.1.4.1.2011.6.164.2.1.0.47NotificationhwAcFreqFaultAlarmTrapscurrentAC frequency is fault. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descri…
1.3.6.1.4.1.2011.6.164.2.1.0.48NotificationhwAcFreqFaultAlarmResumeTrapscurrentAC frequency alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port de…
1.3.6.1.4.1.2011.6.164.2.1.0.49NotificationhwXmuSelfFaultAlarmTrapscurrentThere are some fault in XMU itself. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar…
1.3.6.1.4.1.2011.6.164.2.1.0.50NotificationhwXmuSelfFaultAlarmResumeTrapscurrentXMU fault alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr…
1.3.6.1.4.1.2011.6.164.2.1.0.51NotificationhwRs485CommAlarmTrapscurrentRS485 communication of monitors disconnect. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descripti…
1.3.6.1.4.1.2011.6.164.2.1.0.52NotificationhwRs485CommAlarmResumeTrapscurrentRS485 communication alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm …
1.3.6.1.4.1.2011.6.164.2.1.0.53NotificationhwNetCommAlarmTrapscurrentNetwork communication of monitors disconnect. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descrip…
1.3.6.1.4.1.2011.6.164.2.1.0.54NotificationhwNetCommAlarmResumeTrapscurrentNetwork communication alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar…
1.3.6.1.4.1.2011.6.164.2.1.0.55NotificationhwAcOffLongTimeAlarmTrapscurrentAC power off for a long time alarms happened. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descrip…
1.3.6.1.4.1.2011.6.164.2.1.0.56NotificationhwAcOffLongTimeAlarmResumeTrapscurrentAC power off for a long time alarms resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descripti…
1.3.6.1.4.1.2011.6.164.2.1.0.57NotificationhwSpdAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.58NotificationhwSpdAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.59NotificationhwBadBatteryTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.60NotificationhwBadBatteryResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.61NotificationhwLvd2DisconnectingTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.62NotificationhwLvd2DisconnectingResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.63NotificationhwBattHighTempTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.64NotificationhwBattHighTempResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.65NotificationhwBattLowTempTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.66NotificationhwBattLowTempResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.67NotificationhwDcUltraOverVoltageTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.68NotificationhwDcUltraOverVoltageResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.69NotificationhwDcUltraUnderVoltageTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.70NotificationhwDcUltraUnderVoltageResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.71NotificationhwUmiCommFailTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.72NotificationhwUmiCommFailResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.73NotificationhwShortTestFailTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.74NotificationhwShortTestFailResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.75NotificationhwMissingBattTempSensorTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.76NotificationhwMissingBattTempSensorResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.77NotificationhwBattTempSensorFaultTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.78NotificationhwBattTempSensorFaultResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.79NotificationhwAcOverVoltageTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.80NotificationhwAcOverVoltageResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.81NotificationhwAcUnderVoltageTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.82NotificationhwAcUnderVoltageResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.83NotificationhwTcuFanAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.84NotificationhwTcuFanAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.85NotificationhwTcuDcAirAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.86NotificationhwTcuDcAirAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.87NotificationhwTripBreakAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.88NotificationhwTripBreakAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.89NotificationhwTripBatteryCabinetAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.90NotificationhwTripBattCabAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.103NotificationhwBattTestAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.104NotificationhwBattTestAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.105NotificationhwBattContactorFaultTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.106NotificationhwBattContactorFaultResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.107NotificationhwBattFuseBreakAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.108NotificationhwBattFuseBreakAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.109NotificationhwDCDAbnormalAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.110NotificationhwDCDAbnormalAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.111NotificationhwACDAbnormalAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.112NotificationhwACDAbnormalAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.113NotificationhwLoadOverCurrentAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.114NotificationhwLoadOverCurrentAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.115NotificationhwEOSNoResponseAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.116NotificationhwEOSNoResponseAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.117NotificationhwEOSOverLoadAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.118NotificationhwEOSOverLoadAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.119NotificationhwInverterAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.120NotificationhwInveterAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.121NotificationhwDGAlarmTrapscurrentDG Alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm …
1.3.6.1.4.1.2011.6.164.2.1.0.122NotificationhwDGAlarmResumeTrapscurrentDG Alarm Resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description,…
1.3.6.1.4.1.2011.6.164.2.1.0.123NotificationhwSSUSummaryAlarmTrapscurrentSSU Group Alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description,…
1.3.6.1.4.1.2011.6.164.2.1.0.124NotificationhwSSUSummaryAlarmResumeTrapscurrentSSU Group Resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description…
1.3.6.1.4.1.2011.6.164.2.1.0.125NotificationhwSSUAlarmTrapscurrentSSU Alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm…
1.3.6.1.4.1.2011.6.164.2.1.0.126NotificationhwSSUAlarmResumeTrapscurrentSSU Alarm Resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description…
1.3.6.1.4.1.2011.6.164.2.1.0.127NotificationhwTemp1SensorAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.128NotificationhwTemp1SensorAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.129NotificationhwTemp2SensorAlarmTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.130NotificationhwTemp2SensorAlarmResumeTrapscurrentDescription.
1.3.6.1.4.1.2011.6.164.2.1.0.131NotificationhwRectCapacityAlarmTrapscurrentLow Rectifier Capacity or High Rectifier Capacity Alarm happened.
1.3.6.1.4.1.2011.6.164.2.1.0.132NotificationhwRectCapacityAlarmResumeTrapscurrentLow Rectifier Capacity or High Rectifier Capacity Alarm Resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.133NotificationhwTcucTempSensorFaultAlarmTrapscurrentThe TCUC cabient temperature sensor fault alarm happened.
1.3.6.1.4.1.2011.6.164.2.1.0.134NotificationhwTcucTempSensorFaultAlarmResumeTrapscurrentThe TCUC cabient temperature sensor fault alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.135NotificationhwTcucFanFaultAlarmTrapscurrentThe TCUC cabient fan fault alarm happened.
1.3.6.1.4.1.2011.6.164.2.1.0.136NotificationhwTcucFanFaultAlarmResumeTrapscurrentThe TCUC cabient fan fault alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.137NotificationhwTcucTempAbnormalAlarmTrapscurrentThe TCUC cabinet temperature is too high or too low
1.3.6.1.4.1.2011.6.164.2.1.0.138NotificationhwTcucTempAbnormalAlarmResumeTrapscurrentThe TCUC cabinet temperature abnormal alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.139NotificationhwTcucDoorOpenAlarmTrapscurrentThe TCUC cabinet door is open.
1.3.6.1.4.1.2011.6.164.2.1.0.140NotificationhwTcucDoorOpenAlarmResumeTrapscurrentThe TCUC cabient door open alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.141NotificationhwTcucSmokeAlarmTrapscurrentThe TCUC cabient smoke alarm happened.
1.3.6.1.4.1.2011.6.164.2.1.0.142NotificationhwTcucSmokeAlarmResumeTrapscurrentThe TCUC cabient smoke alarm resumed
1.3.6.1.4.1.2011.6.164.2.1.0.143NotificationhwTcucWaterAlarmTrapscurrentThe TCUC cabient water alarm happend.
1.3.6.1.4.1.2011.6.164.2.1.0.144NotificationhwTcucWaterAlarmResumeTrapscurrentThe TCUC cabient water alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.145NotificationhwTcucCommFailAlarmTrapscurrentThe TCUC cabient failed communicate with the monitor.
1.3.6.1.4.1.2011.6.164.2.1.0.146NotificationhwTcucCommFailAlarmResumeTrapscurrentThe TCUC cabient communication fail alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.147NotificationhwEsduDigitalInputAlarmTrapscurrentThe ESDU Spare digital fault. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port…
1.3.6.1.4.1.2011.6.164.2.1.0.148NotificationhwEsduDigitalInputAlarmResumeTrapscurrentThe ESDU Spare digital alarm resume.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar…
1.3.6.1.4.1.2011.6.164.2.1.0.149NotificationhwEsduDoorOpenAlarmTrapscurrentThe ESDU door is open.
1.3.6.1.4.1.2011.6.164.2.1.0.150NotificationhwEsduDoorOpenAlarmResumeTrapscurrentThe ESDU door open alarm resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.151NotificationhwEsduTemp1SensorFaultAlarmTrapscurrentThe ESDU TEMP1 sensor is faulty.
1.3.6.1.4.1.2011.6.164.2.1.0.152NotificationhwEsduTemp1SensorFaultAlarmResumeTrapscurrentThe ESDU TEMP1 sensor fault alarm recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.153NotificationhwEsduTemp1SensorMissAlarmTrapscurrentThe ESDU TEMP1 sensor is missing.
1.3.6.1.4.1.2011.6.164.2.1.0.154NotificationhwEsduTemp1SensorMissAlarmResumeTrapscurrentThe ESDU TEMP1 sensor missing alarm recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.155NotificationhwEsduTemp2SensorFaultAlarmTrapscurrentThe ESDU TEMP2 sensor is faulty.
1.3.6.1.4.1.2011.6.164.2.1.0.156NotificationhwEsduTemp2SensorFaultAlarmResumeTrapscurrentThe ESDU TEMP2 sensor fault alarm recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.157NotificationhwEsduTemp2SensorMissAlarmTrapscurrentThe ESDU TEMP2 sensor is missing.
1.3.6.1.4.1.2011.6.164.2.1.0.158NotificationhwEsduTemp2SensorMissAlarmResumeTrapscurrentThe ESDU TEMP2 sensor missing alarm recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.159NotificationhwEsduBtempSensorFaultAlarmTrapscurrentThe ESDU BTEMP sensor is faulty.
1.3.6.1.4.1.2011.6.164.2.1.0.160NotificationhwEsduBtempSensorFaultAlarmResumeTrapscurrentThe ESDU BTEMP sensor fault alarm recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.161NotificationhwEsduBtempSensorMissAlarmTrapscurrentThe ESDU BTEMP sensor is missing.
1.3.6.1.4.1.2011.6.164.2.1.0.162NotificationhwEsduBtempSensorMissAlarmResumeTrapscurrentThe ESDU BTEMP sensor missing alarm recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.163NotificationhwEsduTemp1AlarmTrapscurrentThe ESDU TEMP1 temperature is out of range��too high or too low��.
1.3.6.1.4.1.2011.6.164.2.1.0.164NotificationhwEsduTemp1AlarmResumeTrapscurrentThe ESDU TEMP1 temperature alarm resume.
1.3.6.1.4.1.2011.6.164.2.1.0.165NotificationhwEsduTemp2AlarmTrapscurrentThe ESDU TEMP2 temperature is out of range��too high or too low��.
1.3.6.1.4.1.2011.6.164.2.1.0.166NotificationhwEsduTemp2AlarmResumeTrapscurrentThe ESDU TEMP2 temperature alarm resume.
1.3.6.1.4.1.2011.6.164.2.1.0.167NotificationhwEsduCommAlarmTrapscurrentThe Moniter cannot commuicate with the ESDU.
1.3.6.1.4.1.2011.6.164.2.1.0.168NotificationhwEsduCommAlarmResumeTrapscurrentThe communication between monitor and ESDU recovers.
1.3.6.1.4.1.2011.6.164.2.1.0.169NotificationhwBatteryLowCapacityAlarmTrapscurrentThe capacity of batteries is low.
1.3.6.1.4.1.2011.6.164.2.1.0.170NotificationhwBatteryLowCapacityAlarmResumeTrapscurrentThe alarm of low capacity resumed.
1.3.6.1.4.1.2011.6.164.2.1.0.171NotificationhwBatteryLostAlarmTrapscurrentSome battery strings could be lost, when the alarm happened.
1.3.6.1.4.1.2011.6.164.2.1.0.172NotificationhwBatteryLostAlarmResumeTrapscurrentIf all the battery strings can be detected, the alarm of battery losting resume.
1.3.6.1.4.1.2011.6.164.2.1.0.181NotificationhwPvLostAlarmTrapscurrent
1.3.6.1.4.1.2011.6.164.2.1.0.182NotificationhwPvLostAlarmResumeTrapscurrent
1.3.6.1.4.1.2011.6.164.2.1.0.187NotificationhwAtsAlarmTrapcurrentATS Alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm…
1.3.6.1.4.1.2011.6.164.2.1.0.188NotificationhwAtsAlarmResumeTrapcurrentATS Alarm Resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description…
1.3.6.1.4.1.2011.6.164.2.1.2NodehwAcbGroupAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.2.0NodehwAcbGroupAlmTrapTablePrefix
1.3.6.1.4.1.2011.6.164.2.1.2.0.99NotificationhwAcbGroupAlarmTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.2.0.100NotificationhwAcbGroupAarlmResumeTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.3NodehwAcbAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.3.0NodehwAcbAlmTrapTablePrefix
1.3.6.1.4.1.2011.6.164.2.1.3.0.99NotificationhwAcbAlarmTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.3.0.100NotificationhwAcbAarlmResumeTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.4NodehwInverterTrapTable
1.3.6.1.4.1.2011.6.164.2.1.4.0NodehwInverterTrapPrefix
1.3.6.1.4.1.2011.6.164.2.1.4.0.1NotificationhwInverterCommFailAlarmTrapcurrentCommunication Failure. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.2NotificationhwInverterCommFailAlarmResumeTrapcurrentCommunication Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.3NotificationhwInverterFanFaultAlarmTrapcurrentFan Failure. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site desc…
1.3.6.1.4.1.2011.6.164.2.1.4.0.4NotificationhwInverterFanFaultAlarmResumeTrapcurrentFan Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Si…
1.3.6.1.4.1.2011.6.164.2.1.4.0.5NotificationhwInverterACOutLowAlarmTrapcurrentAC Output Undervoltage. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID…
1.3.6.1.4.1.2011.6.164.2.1.4.0.6NotificationhwInverterACOutLowAlarmResumeTrapcurrentAC Output Undervoltage Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address…
1.3.6.1.4.1.2011.6.164.2.1.4.0.7NotificationhwInverterACOutHighAlarmTrapcurrentAC Output Overvoltage. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.8NotificationhwInverterACOutHighAlarmResumeTrapcurrentAC Output Overvoltage Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.9NotificationhwInverterModFaultAlarmTrapcurrentModule Fault. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site des…
1.3.6.1.4.1.2011.6.164.2.1.4.0.10NotificationhwInverterModFaultAlarmResumeTrapcurrentModule Fault Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, S…
1.3.6.1.4.1.2011.6.164.2.1.4.0.11NotificationhwInverterModTempHighAlarmTrapcurrentTemperature Too High. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, …
1.3.6.1.4.1.2011.6.164.2.1.4.0.12NotificationhwInverterModTempHighAlarmResumeTrapcurrentTemperature Too High Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, …
1.3.6.1.4.1.2011.6.164.2.1.4.0.13NotificationhwInverterModTempLowAlarmTrapcurrentTemperature Too Low. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, S…
1.3.6.1.4.1.2011.6.164.2.1.4.0.14NotificationhwInverterModTempLowAlarmResumeTrapcurrentTemperature Too Low Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, N…
1.3.6.1.4.1.2011.6.164.2.1.4.0.15NotificationhwInvertersACPhaseShortAlarmTrapcurrentAC Input Phase Not Ready. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE …
1.3.6.1.4.1.2011.6.164.2.1.4.0.16NotificationhwInvertersACPhaseShortAlarmResumeTrapcurrentAC Input Phase Not Ready Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant addre…
1.3.6.1.4.1.2011.6.164.2.1.4.0.17NotificationhwInverterModOffAlarmTrapcurrentModule Off. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site descr…
1.3.6.1.4.1.2011.6.164.2.1.4.0.18NotificationhwInverterModOffAlarmResumeTrapcurrentModule Off Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Sit…
1.3.6.1.4.1.2011.6.164.2.1.4.0.19NotificationhwInverterACInAbnAlarmTrapcurrentAC Input Abnormal. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Sit…
1.3.6.1.4.1.2011.6.164.2.1.4.0.20NotificationhwInverterACInAbnAlarmResumeTrapcurrentAC Input Abnormal Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE …
1.3.6.1.4.1.2011.6.164.2.1.4.0.21NotificationhwInverterDCInLowAlarmTrapcurrentDC Input Undervoltage. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.22NotificationhwInverteDCInLowAlarmResumeTrapcurrentDC Input Undervoltage Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.23NotificationhwInverterDCInHighAlarmTrapcurrentDC Input Overvoltage. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, …
1.3.6.1.4.1.2011.6.164.2.1.4.0.24NotificationhwInverterDCInHighAlarmResumeTrapcurrentDC Input Overvoltage Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, …
1.3.6.1.4.1.2011.6.164.2.1.4.0.25NotificationhwInverterModCommFailAlarmTrapcurrentModule Communication Failure. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address,…
1.3.6.1.4.1.2011.6.164.2.1.4.0.26NotificationhwInverterModCommFailAlarmResumeTrapcurrentModule Communication Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant a…
1.3.6.1.4.1.2011.6.164.2.1.4.0.27NotificationhwInverterNoACInAlarmTrapcurrentNo AC In. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site descrip…
1.3.6.1.4.1.2011.6.164.2.1.4.0.28NotificationhwInverterNoACInAlarmResumeTrapcurrentNo AC In Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site …
1.3.6.1.4.1.2011.6.164.2.1.4.0.29NotificationhwInverterNoDCInAlarmTrapcurrentNo DC In. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site descrip…
1.3.6.1.4.1.2011.6.164.2.1.4.0.30NotificationhwInverterNoDCInAlarmResumeTrapcurrentNo DC In Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site …
1.3.6.1.4.1.2011.6.164.2.1.4.0.31NotificationhwInverterT2SFaultAlarmTrapcurrentT2S Fault. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site descri…
1.3.6.1.4.1.2011.6.164.2.1.4.0.32NotificationhwInverterT2SFaultAlarmResumeTrapcurrentT2S Fault Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site…
1.3.6.1.4.1.2011.6.164.2.1.4.0.33NotificationhwInvertModMissAlarmTrapcurrentMissing Module. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site d…
1.3.6.1.4.1.2011.6.164.2.1.4.0.34NotificationhwInvertModMissAlarmResumeTrapcurrentMissing Module Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID,…
1.3.6.1.4.1.2011.6.164.2.1.6NodehwIboxAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.6.0NodehwIboxAlmTrapPrefix
1.3.6.1.4.1.2011.6.164.2.1.6.0.1NotificationhwIboxCommFailAlarmTrapcurrentIbox Communication Failure. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, N…
1.3.6.1.4.1.2011.6.164.2.1.6.0.2NotificationhwIboxCommFailAlarmResumeTrapcurrentIbox Communication Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant add…
1.3.6.1.4.1.2011.6.164.2.1.7NodehwIbatAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.7.0NodehwIbatAlmTrapPrefix
1.3.6.1.4.1.2011.6.164.2.1.7.0.1NotificationhwIbatAlarmTrapcurrentIbat Communication Failure. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, N…
1.3.6.1.4.1.2011.6.164.2.1.7.0.2NotificationhwIbatAlarmResumeTrapcurrentIbat Communication Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant add…
1.3.6.1.4.1.2011.6.164.2.1.8NodehwAcAmmeterAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.8.0NodehwAcAmmeterAlmTrapPrefix
1.3.6.1.4.1.2011.6.164.2.1.8.0.1NotificationhwAcAmmeterAlarmTrapcurrentAc Ammeter. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site descr…
1.3.6.1.4.1.2011.6.164.2.1.8.0.2NotificationhwAcAmmeterAlarmResumeTrapcurrentAc Ammeter . Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administrant address, NE ID, Site desc…
1.3.6.1.4.1.2011.6.164.2.1.9NodehwCommExBoardAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.9.0NodehwCommExBoardAlmTrapPrefix
1.3.6.1.4.1.2011.6.164.2.1.9.0.1NotificationhwCommExBoardCommFailAlarmTrapcurrentCommunication Expansion Board Communication Failure Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site…
1.3.6.1.4.1.2011.6.164.2.1.9.0.2NotificationhwCommExBoardCommFailAlarmResumeTrapcurrentCommunication Expansion Board Communication Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site na…
1.3.6.1.4.1.2011.6.164.2.1.10NodehwDGCommExBoardAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.10.0NodehwDGCommExBoardAlmTrapPrefix
1.3.6.1.4.1.2011.6.164.2.1.10.0.1NotificationhwDGCommExBoardCommFailAlarmTrapcurrentDG Comm Ex Board Communication Failure. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site administran…
1.3.6.1.4.1.2011.6.164.2.1.10.0.2NotificationhwDGCommExBoardCommFailAlarmResumeTrapcurrentDG Comm Ex Board Communication Failure Resume. Its correlation binding parameters: Site alarm serial number (SN), Alarm name, Alarm level, Site name, Site admi…
1.3.6.1.4.1.2011.6.164.2.1.13NodehwElockAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.13.0NodehwElockAlmTrapTablePrefix
1.3.6.1.4.1.2011.6.164.2.1.13.0.1NotificationhwElockAlarmTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.13.0.2NotificationhwElockAlarmResumeTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.14NodehwTemHumAlmTrapTable
1.3.6.1.4.1.2011.6.164.2.1.14.0NodehwTemHumAlmTrapTablePrefix
1.3.6.1.4.1.2011.6.164.2.1.14.0.1NotificationhwTemHumAlarmTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.1.14.0.2NotificationhwTemHumAlarmResumeTrapcurrent/
1.3.6.1.4.1.2011.6.164.2.2NodehwSiteDevicesTraps
1.3.6.1.4.1.2011.6.164.2.2.0NodehwDevicesTrapsPrefix
1.3.6.1.4.1.2011.6.164.2.2.0.1NotificationhwRectifiersInslotChangecurrentWhen the presence status of a rectifier changes, the node reports an event. Then the NMS adds or deletes the corresponding entry to or from hwRectConfigTable o…
1.3.6.1.4.1.2011.6.164.2.2.0.2NotificationhwBatterysInslotChangecurrentWhen the presence status of a battery string changes, the node reports an event. Then the NMS adds or deletes the corresponding entry to or from hwBatttConfigT…
1.3.6.1.4.1.2011.6.164.2.2.0.3NotificationhwBattTestRecordsAddcurrentAfter a new discharge test is conducted on a battery group, the node reports an event. The bound information includes the site address, site name, site descrip…
1.3.6.1.4.1.2011.6.164.2.2.0.4NotificationhwEnvTempSensInslotChangecurrentWhen the presence status of an environment temperature sensor changes, the node reports an event. Then the NMS adds or deletes the corresponding entry to or fr…
1.3.6.1.4.1.2011.6.164.2.2.0.5NotificationhwEnvHumiSensInslotChangecurrentWhen the presence status of an environment humidity sensor changes, the trap reports an event. Then the NMS adds or deletes the corresponding entry to or from …
1.3.6.1.4.1.2011.6.164.2.2.0.6NotificationhwPDEsInslotChangecurrentDescription.
1.3.6.1.4.1.2011.6.164.2.2.0.7NotificationhwInvertersInslotChangecurrentDescription.
1.3.6.1.4.1.2011.6.164.2.3NodehwSiteStatusTrap
1.3.6.1.4.1.2011.6.164.2.3.0NodehwSiteStatusTrapPrefix
1.3.6.1.4.1.2011.6.164.2.3.0.1NotificationhwAcInputFaultTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.2NotificationhwRectifierFaultTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.3NotificationhwBatteryDischargeTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.4NotificationhwBatteryLowVoltageTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.5NotificationhwBatteryUltraLowVoltageTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.6NotificationhwBatteryDisconnectTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.7NotificationhwFuseBrokenTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.8NotificationhwLowRecitiferCapacityTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.9NotificationhwBatteryTestNegativeTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.10NotificationhwUrgentAlarmTrapcurrent
1.3.6.1.4.1.2011.6.164.2.3.0.11NotificationhwNonurgentAlarmTrapcurrent
1.3.6.1.4.1.2011.6.164.3NodehwSiteEquip
1.3.6.1.4.1.2011.6.164.3.1TablehwSiteCameraTablenot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.3.1.1RowhwSiteCameraEntrynot-accessiblecurrent/
1.3.6.1.4.1.2011.6.164.3.1.1.1ColumnhwSiteCameraIpread-onlycurrentthe camera ip adress.
1.3.6.1.4.1.2011.6.164.3.1.1.2ColumnhwSiteCameraPortread-onlycurrentcamera connect port number.
1.3.6.1.4.1.2011.6.164.3.1.1.5ColumnhwSiteCameraPhotSetAlarmTyperead-writecurrentYou can set the alarm type to obtain the historical picture of the camera-related alarm shooting.
1.3.6.1.4.1.2011.6.164.3.1.1.6ColumnhwSiteCameraAssociatedAlarmPicture1read-onlycurrentAssociated alarm picture 1.
1.3.6.1.4.1.2011.6.164.3.1.1.7ColumnhwSiteCameraAssociatedAlarmPicture2read-onlycurrentAssociated alarm picture 2.
1.3.6.1.4.1.2011.6.164.3.1.1.8ColumnhwSiteCameraAssociatedAlarmPicture3read-onlycurrentAssociated alarm picture 3.
1.3.6.1.4.1.2011.6.164.3.1.1.9ColumnhwSiteCameraAssociatedAlarmPicture4read-onlycurrentAssociated alarm picture 4.
1.3.6.1.4.1.2011.6.164.3.1.1.10ColumnhwSiteCameraAssociatedAlarmPicture5read-onlycurrentAssociated alarm picture 5.
1.3.6.1.4.1.2011.6.164.3.1.1.11ColumnhwSiteCameraAssociatedAlarmPicture6read-onlycurrentAssociated alarm picture 6.
1.3.6.1.4.1.2011.6.164.3.1.1.12ColumnhwSiteCameraAssociatedAlarmPicture7read-onlycurrentAssociated alarm picture 7.
1.3.6.1.4.1.2011.6.164.3.1.1.13ColumnhwSiteCameraAssociatedAlarmPicture8read-onlycurrentAssociated alarm picture 8.
1.3.6.1.4.1.2011.6.164.3.1.1.14ColumnhwSiteCameraAssociatedAlarmPicture9read-onlycurrentAssociated alarm picture 9.
1.3.6.1.4.1.2011.6.164.3.1.1.15ColumnhwSiteCameraAssociatedAlarmPicture10read-onlycurrentAssociated alarm picture 10.
1.3.6.1.4.1.2011.6.164.3.1.1.16ColumnhwSiteCameraAdditionalAssociatedAlarmPicturesread-onlycurrentAdditional associated alarm pictures.
Type Definitions
NameSyntaxStatusDescription
DateAndTimeOCTET STRING (SIZE (8..11))currentDescription.
DisplayStringOCTET STRING (SIZE (1..64))currentDescription.
MeasuresRangeInteger32currentDescription.
RowStatusINTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) }currentDescription.
RunStatusINTEGER { unknow(1), normal(2), alarm(3) }currentThis integer value represents running status of the system. Depending on situation there may be limits on allowed values. Operational values: (1) unknown - status has not yet been defined (2) normal - there are no activ…
TruthValueINTEGER { true(1), false(2) }currentDescription.