EXTREME-TRAP-MIB

18 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1916Nodeextremenetworks
1.3.6.1.4.1.1916.0NodeextremeV1Traps
1.3.6.1.4.1.1916.0.6NotificationextremeOverheatcurrentA overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has suficiently cooled such tha…
1.3.6.1.4.1.1916.0.7NotificationextremeFanfailedcurrentA fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation.
1.3.6.1.4.1.1916.0.8NotificationextremeFanOKcurrentA fan has transitioned out of a failure state and is now operating correctly.
1.3.6.1.4.1.1916.0.9NotificationextremeInvalidLoginAttemptcurrentA user attempted to login to console or by telnet but was refused access due to incorrect username or password
1.3.6.1.4.1.1916.0.10NotificationextremePowerSupplyFailcurrentOne or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over.
1.3.6.1.4.1.1916.0.11NotificationextremePowerSupplyGoodcurrentOne or more previously bad sources of power to this agent has come back to life without causing an agent restart.
1.3.6.1.4.1.1916.0.12NotificationextremeRpsAlarmcurrentAttached Redundant Power Supply device is indicating an alarm condition.
1.3.6.1.4.1.1916.0.13NotificationextremeRpsNoAlarmcurrentAttached Redundant Power Supply device is no longer indicating an alarm condition.
1.3.6.1.4.1.1916.0.14NotificationextremeSmartTrapcurrentSignifies that the value of one of the object identifiers (or the value of an object below that in the MIB tree) defined in the extremeSmartTrapRulesTable has …
1.3.6.1.4.1.1916.0.15NotificationextremeModuleStateChangedcurrentSignifies that the value of the extremeSlotModuleState for the specified extremeSlotNumber has changed.
1.3.6.1.4.1.1916.0.17NotificationextremeEsrpStateChangecurrentSignifies Esrp state change
1.3.6.1.4.1.1916.0.18NotificationextremeSlbUnitAddedcurrentThe server load balancer has activated a group of virtual servers that it normally would not activate. This may be due to the failure of another server load ba…
1.3.6.1.4.1.1916.0.19NotificationextremeSlbUnitRemovedcurrentThe server load balancer has deactivated a group of virtual servers that it normally has active. This indicates that something is wrong in the server load bala…
1.3.6.1.4.1.1916.0.20NotificationextremeEdpNeighborAddedcurrentThis node discovers a new neighbor through Extreme Discovery Protocol.
1.3.6.1.4.1.1916.0.21NotificationextremeEdpNeighborRemovedcurrentNo EDP updates are received from this neighbor within the configured timeout period and this neighbor entry is aged out by the device.
1.3.6.1.4.1.1916.0.22NotificationextremeCpuHealthCheckFailedcurrentCpu HealthCheck has failed. This trap is supported only in ExtremeWare.