EXTREME-TRAP-MIB
18 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1916 | Nodeextremenetworks | |||
| 1.3.6.1.4.1.1916.0 | NodeextremeV1Traps | |||
| 1.3.6.1.4.1.1916.0.6 | NotificationextremeOverheat | current | A overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has suficiently cooled such tha… | |
| 1.3.6.1.4.1.1916.0.7 | NotificationextremeFanfailed | current | A fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation. | |
| 1.3.6.1.4.1.1916.0.8 | NotificationextremeFanOK | current | A fan has transitioned out of a failure state and is now operating correctly. | |
| 1.3.6.1.4.1.1916.0.9 | NotificationextremeInvalidLoginAttempt | current | A user attempted to login to console or by telnet but was refused access due to incorrect username or password | |
| 1.3.6.1.4.1.1916.0.10 | NotificationextremePowerSupplyFail | current | One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over. | |
| 1.3.6.1.4.1.1916.0.11 | NotificationextremePowerSupplyGood | current | One or more previously bad sources of power to this agent has come back to life without causing an agent restart. | |
| 1.3.6.1.4.1.1916.0.12 | NotificationextremeRpsAlarm | current | Attached Redundant Power Supply device is indicating an alarm condition. | |
| 1.3.6.1.4.1.1916.0.13 | NotificationextremeRpsNoAlarm | current | Attached Redundant Power Supply device is no longer indicating an alarm condition. | |
| 1.3.6.1.4.1.1916.0.14 | NotificationextremeSmartTrap | current | Signifies that the value of one of the object identifiers (or the value of an object below that in the MIB tree) defined in the extremeSmartTrapRulesTable has … | |
| 1.3.6.1.4.1.1916.0.15 | NotificationextremeModuleStateChanged | current | Signifies that the value of the extremeSlotModuleState for the specified extremeSlotNumber has changed. | |
| 1.3.6.1.4.1.1916.0.17 | NotificationextremeEsrpStateChange | current | Signifies Esrp state change | |
| 1.3.6.1.4.1.1916.0.18 | NotificationextremeSlbUnitAdded | current | The server load balancer has activated a group of virtual servers that it normally would not activate. This may be due to the failure of another server load ba… | |
| 1.3.6.1.4.1.1916.0.19 | NotificationextremeSlbUnitRemoved | current | The server load balancer has deactivated a group of virtual servers that it normally has active. This indicates that something is wrong in the server load bala… | |
| 1.3.6.1.4.1.1916.0.20 | NotificationextremeEdpNeighborAdded | current | This node discovers a new neighbor through Extreme Discovery Protocol. | |
| 1.3.6.1.4.1.1916.0.21 | NotificationextremeEdpNeighborRemoved | current | No EDP updates are received from this neighbor within the configured timeout period and this neighbor entry is aged out by the device. | |
| 1.3.6.1.4.1.1916.0.22 | NotificationextremeCpuHealthCheckFailed | current | Cpu HealthCheck has failed. This trap is supported only in ExtremeWare. |