MIB Viewer

File-Transfer-MIB

74 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.231Nodesni
1.3.6.1.4.1.231.2NodesniProductMibs
1.3.6.1.4.1.231.2.18NodesniFT
1.3.6.1.4.1.231.2.18.1NodesniFTStartandStop
1.3.6.1.4.1.231.2.18.1.1ScalarftStartandStopread-writemandatoryObject is supported in FT-BS2000 and FT-SINIX: Reading: Status of FT STARTED or NOT STARTED; writing: START or TERMINATE Filetransfer
1.3.6.1.4.1.231.2.18.1.2ScalarftStartandStopFTAMread-writemandatoryObject is supported only in FT-SINIX: Reading: Status of FTAM - on or off; writing: START or TERMINATE FTAM
1.3.6.1.4.1.231.2.18.2NodesniFTSysParam
1.3.6.1.4.1.231.2.18.2.1ScalarftSysparVersionread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Type and version of FT-system e.g. FT-BS2000 V5.2A20
1.3.6.1.4.1.231.2.18.2.2ScalarftSysparTransportUnitSizeread-writemandatoryObject is supported in FT-BS2000 and FT-SINIX: Maximum size of transport unit (in Bytes)
1.3.6.1.4.1.231.2.18.2.3ScalarftSysparTaskLimitread-writemandatoryObject is supported only in FT-BS2000: Maximum number of tasks that can be reserved simultaneously for the execution of the FT requests
1.3.6.1.4.1.231.2.18.2.4ScalarftSysparConnectionLimitread-writemandatoryObject is supported only in FT-BS2000: Maximum number of transport connections that can be reserved for the execution of FT requests
1.3.6.1.4.1.231.2.18.2.5ScalarftSysparRequestWaitLevelread-writemandatoryObject is supported only in FT-BS2000: Number of waiting requests that must exist before a parallel connection to that remote system is created
1.3.6.1.4.1.231.2.18.2.6ScalarftSysparPartnerCheckread-writemandatoryObject is supported only in FT-BS2000: Modification/Display of the extended authentication check
1.3.6.1.4.1.231.2.18.2.7ScalarftSysparMaxOSPread-writemandatoryObject is supported only in FT-SINIX: Maximum number of requests issued locally (outbound) that can be processed simultaneously
1.3.6.1.4.1.231.2.18.2.8ScalarftSysparMaxISPread-writemandatoryObject is supported only in FT-SINIX: Maximum number of requests issued remotely (inbound) that can be processed simultaneously
1.3.6.1.4.1.231.2.18.2.9ScalarftSysparProcessorNameread-writemandatoryObject is supported only in FT-SINIX: Processor name assigned to target system
1.3.6.1.4.1.231.2.18.2.10ScalarftSysparStationNameread-writemandatoryObject is supported only in FT-SINIX: Station name assigned to target system
1.3.6.1.4.1.231.2.18.2.11ScalarftSysparCoderead-writemandatoryObject is supported only in FT-SINIX: eXtended Host Code Support (XHCS); possible values: ISO8859-i (i = 1,2,5,6,7,9)
1.3.6.1.4.1.231.2.18.2.12ScalarftSysparMaxInboundReqsread-writemandatoryObject is supported in FT-BS2000 and FT-SINIX (FTOS-only): Maximum number of inbound requests per partner system
1.3.6.1.4.1.231.2.18.2.13ScalarftSysparMaxLifeTimeread-writemandatoryObject is supported in FT-SINIX (FTOS-only) and FT-BS2000: Maximum lifetime (in days) for requests in the request queue (max. 400 days) BS2000: 0 is the value …
1.3.6.1.4.1.231.2.18.3NodesniFTEncryptKey
1.3.6.1.4.1.231.2.18.3.1ScalarftEncryptKeyread-writemandatoryObject is supported in FT-BS2000 and FT-SINIX: Ability to create a new code for encryption
1.3.6.1.4.1.231.2.18.4NodesniFTStatistics
1.3.6.1.4.1.231.2.18.4.1ScalarftStatSuspendread-onlymandatoryObject is supported only in FT-BS2000: Number of requests that are currently in SUSPEND status
1.3.6.1.4.1.231.2.18.4.2ScalarftStatLockedread-onlymandatoryObject is supp. in FT-BS2000 and FT-SINIX (FTOS-only): Number of requests that are currently in LOCKED status
1.3.6.1.4.1.231.2.18.4.3ScalarftStatWaitread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Number of requests that are currently in WAIT status
1.3.6.1.4.1.231.2.18.4.4ScalarftStatActiveread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Number of requests that are currently in ACTIVE status
1.3.6.1.4.1.231.2.18.4.5ScalarftStatCanceledread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Number of reqs that are currently in CANCELED status
1.3.6.1.4.1.231.2.18.4.6ScalarftStatFinishedread-onlymandatoryObject is supp. in FT-BS2000 and FT-SINIX (FTOS-only): Number of reqs that are currently in FINISHED status
1.3.6.1.4.1.231.2.18.4.7ScalarftStatHoldread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Number of requests that are currently in HOLD status
1.3.6.1.4.1.231.2.18.4.8ScalarftStatLocalReqsread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Number of async. requests issued in the local system, but not yet executed
1.3.6.1.4.1.231.2.18.4.9ScalarftStatRemoteReqsread-onlymandatoryObject is supported in FT-BS2000 and FT-SINIX: Number of requests issued in the remote system, but not yet executed
1.3.6.1.4.1.231.2.18.5NodesniFTDiagnostics
1.3.6.1.4.1.231.2.18.5.1ScalarftDiagStatusread-writemandatoryObject is supported in FT-BS2000 and FT-SINIX: Switches FT function on or off; abbreviations are: 1.pos=ftnea, 2.pos=ftam, 3.pos=session s: standard; n: none; …
1.3.6.1.4.1.231.2.18.6NodesniFTTraps
1.3.6.1.4.1.231.2.18.6.1NodeftStopTrapSending a TRAP, if FT has exited/aborted (FT-SINIX and FT-BS2000)
1.3.6.1.4.1.231.2.18.6.2NodeftMaxRequestTrapSending a TRAP, if the maximum number of FT requests is reached (only FT-SINIX)
1.3.6.1.4.1.231.2.18.6.3NodeftErrorLimitTrapSending a TRAP, if the error limit is reached (concerning restarts - only FT-SINIX)
1.3.6.1.4.1.231.2.18.6.4NodeftPartnerStateTrapSending a TRAP, if the Partner changed state (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.5NodeftPartnerUnreachableTrapMaybe Partner ist unreachable (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.6NodeftStartTrapSending a TRAP, if FT has been started (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.7NodeftRequestQueueUpperLimitTrapat least 85 percent of Request file full (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.8NodeftRequestQueueLowerLimitTrapat least 20 percent of Request queue unoccupied (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.9NodeftRequestSuccessfulTrapFt-Request was finished successfully (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.10NodeftRequestErrorTrapFT-Request finished with error (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.11NodeftSubsystemStartTrapSending a TRAP, if Subsystem FT is started (only FT-BS2000)
1.3.6.1.4.1.231.2.18.6.12NodeftSubsystemStopTrapSending a TRAP, if Subsystem FT is stopped (only FT-BS2000)
1.3.6.1.4.1.231.2.18.7NodesniFTPollInterval
1.3.6.1.4.1.231.2.18.7.1ScalarftPollIntervalread-writemandatoryObject is supported only in FT-SINIX. The poll interval is the time in minutes between poll actions for verifying whether FT has been stopped, in order to send…
1.3.6.1.4.1.231.2.18.8NodesniFTPartners
1.3.6.1.4.1.231.2.18.8.1TableftPartnerTablenot-accessiblemandatoryTable of FT or FTAM-Partners supported in FT-BS2000
1.3.6.1.4.1.231.2.18.8.1.1RowftPartnerEntrynot-accessiblemandatoryEntry describes one FT-(FTAM-)Partner
1.3.6.1.4.1.231.2.18.8.1.1.1ColumnftPartnerNameread-onlymandatoryObject is supported in FT-BS2000: Name of FT-Partner
1.3.6.1.4.1.231.2.18.8.1.1.2ColumnftPartnerTyperead-onlymandatoryObject is supported in FT-BS2000: Partner to be reached with openFT / FTAM - Protocol
1.3.6.1.4.1.231.2.18.8.1.1.3ColumnftPartnerStateread-writemandatoryObject is supported in FT-BS2000: Status of FT-Partner READ: Status ACT - AINACT, WRITE: Status ACT, DEACT, ADEAC
1.3.6.1.4.1.231.2.18.8.1.1.4ColumnftPartnerNetworkAddrread-onlymandatoryObject is supported in FT-BS2000: Layer 3 Address of Partner
1.3.6.1.4.1.231.2.18.8.1.1.5ColumnftPartnerTransportSelread-onlymandatoryObject is supported in FT-BS2000: Layer 4 Address of Partner
1.3.6.1.4.1.231.2.18.8.1.1.6ColumnftPartnerSessionSelread-onlymandatoryObject is supported in FT-BS2000: Layer 5 Address of Partner
1.3.6.1.4.1.231.2.18.8.1.1.7ColumnftPartnerPresentationSelread-onlymandatoryObject is supported in FT-BS2000: Layer 6 Address of Partner
1.3.6.1.4.1.231.2.18.9NodesniFTTrapData
1.3.6.1.4.1.231.2.18.9.1ScalarftRequestIDnot-accessiblemandatoryTransfer ID of FT-Request (only FT-BS2000)
1.3.6.1.4.1.231.2.18.9.2ScalarftRequestInitiatornot-accessiblemandatoryInitiator of FT-Request (only FT-BS2000)
1.3.6.1.4.1.231.2.18.9.3ScalarftRequestPartnerNamenot-accessiblemandatoryPartner of FT-Request (only FT-BS2000)
1.3.6.1.4.1.231.2.18.9.4ScalarftRequestUserIDnot-accessiblemandatoryUserID of FT-Request (only FT-BS2000)
1.3.6.1.4.1.231.2.18.9.5ScalarftRequestFileNamenot-accessiblemandatoryname of transferred File (only FT-BS2000)
1.3.6.1.4.1.231.2.18.9.6ScalarftRequestErrornot-accessiblemandatoryError in Request (only FT-BS2000)
1.3.6.1.4.1.231.2.18.10NodesniFTTrapSwitches
1.3.6.1.4.1.231.2.18.10.1ScalarftTrapsSubsystemStateread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the traps ftSubsystemStartTrap and ftSubsystemStopTrap
1.3.6.1.4.1.231.2.18.10.2ScalarftTrapsFTStateread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the traps ftStopTrap and ftStartTrap
1.3.6.1.4.1.231.2.18.10.3ScalarftTrapsPartStateread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the trap ftPartnerStateTrap
1.3.6.1.4.1.231.2.18.10.4ScalarftTrapsPartnerUnreachableread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the trap ftPartnerUnreachableTrap
1.3.6.1.4.1.231.2.18.10.5ScalarftTrapsRequestQueueStateread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the traps ftRequestQueueLowerLimitTrap and ftRequestQueueUpperLimitTrap
1.3.6.1.4.1.231.2.18.10.6ScalarftTrapsTransSuccread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the trap ftRequestSuccessfulTrap
1.3.6.1.4.1.231.2.18.10.7ScalarftTrapsTransFailread-writemandatoryObject is supported in FT-BS2000 only: Switch on/off sending of the trap ftRequestErrorTrap