GDC7616-MIB
117 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.498 | Nodegdc | |||
| 1.3.6.1.4.1.498.12 | Nodebql2 | |||
| 1.3.6.1.4.1.498.12.4 | Nodeuas7616 | |||
| 1.3.6.1.4.1.498.12.4.1 | Scalaruas7616MIBVersion | read-only | mandatory | The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is… |
| 1.3.6.1.4.1.498.12.4.2 | Tableuas7616WhatAreYouTable | not-accessible | mandatory | The GDC 7616 What Are You Table. |
| 1.3.6.1.4.1.498.12.4.2.1 | Rowuas7616WhatAreYouEntry | not-accessible | mandatory | An entry in the GDC 7616 What Are You table. |
| 1.3.6.1.4.1.498.12.4.2.1.1 | Columnuas7616WhatAreYouIndex | read-only | mandatory | This object is the identifier of the 7616 What Are You table. |
| 1.3.6.1.4.1.498.12.4.2.1.2 | Columnuas7616CodeRev | read-only | mandatory | This function returns the firmware code level. Example A- ,B- |
| 1.3.6.1.4.1.498.12.4.2.1.3 | Columnuas7616AlarmStatus | read-only | mandatory | The current alarms of the unit without the alarm masks. |
| 1.3.6.1.4.1.498.12.4.2.1.4 | Columnuas7616SystemTimingGenStatus | read-only | mandatory | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both. |
| 1.3.6.1.4.1.498.12.4.3 | Tableuas7616ConfigTable | not-accessible | mandatory | The GDC 7616 configuration table. |
| 1.3.6.1.4.1.498.12.4.3.1 | Rowuas7616ConfigEntry | not-accessible | mandatory | A listing of GDC 2B1Q 7616 options. |
| 1.3.6.1.4.1.498.12.4.3.1.1 | Columnuas7616ConfigIndex | read-only | mandatory | A unique index for the Configuration Table. |
| 1.3.6.1.4.1.498.12.4.3.1.2 | Columnuas7616TXClockSource | read-write | mandatory | Object to select the Transmit Clock Source for the 7616. |
| 1.3.6.1.4.1.498.12.4.3.1.3 | Columnuas7616TerminationType | read-write | mandatory | Object to select the Termination Type for the 7616. |
| 1.3.6.1.4.1.498.12.4.3.1.4 | Columnuas7616ChADataRate | read-write | mandatory | Object to select the Data Rate on Channel A, Loop n. |
| 1.3.6.1.4.1.498.12.4.3.1.5 | Columnuas7616ChBDataRate | read-write | mandatory | Object to select the Data Rate on Channel B, Loop n. |
| 1.3.6.1.4.1.498.12.4.5 | Tableuas7616ControlTable | not-accessible | mandatory | The GDC 7616 Control Table. |
| 1.3.6.1.4.1.498.12.4.5.1 | Rowuas7616ControlEntry | not-accessible | mandatory | An entry in the GDC 7616 Control table. |
| 1.3.6.1.4.1.498.12.4.5.1.1 | Columnuas7616ControlIndex | read-only | mandatory | This object is the identifier of the 7616 Control table. |
| 1.3.6.1.4.1.498.12.4.5.1.2 | Columnuas7616SoftReset | read-write | mandatory | Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only. |
| 1.3.6.1.4.1.498.12.4.5.1.3 | Columnuas7616EraseConfig | read-write | mandatory | Forces an erase of the stored configuration in the network element. The erase selection is write only. |
| 1.3.6.1.4.1.498.12.4.5.1.4 | Columnuas7616LEDStatus | read-only | mandatory | The GDC 7616 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - loop 1 channel A (00 = No Change 01 = … |
| 1.3.6.1.4.1.498.12.4.5.1.5 | Columnuas7616InterfaceType | read-write | mandatory | Object used to configure the transmission interface type. |
| 1.3.6.1.4.1.498.12.4.5.1.6 | Columnuas7616SysTimingGen | read-write | mandatory | Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(… |
| 1.3.6.1.4.1.498.12.4.5.1.7 | Columnuas7616ResetIntervals | read-write | mandatory | This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero. |
| 1.3.6.1.4.1.498.12.4.5.1.8 | Columnuas7616SysUpTime | read-only | mandatory | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MI… |
| 1.3.6.1.4.1.498.12.4.5.1.9 | Columnuas7616SetRealTime | read-write | mandatory | Number of seconds from midnight Dec 31, 1969. |
| 1.3.6.1.4.1.498.12.4.5.1.10 | Columnuas7616ModuleClkSrc | read-write | mandatory | This variable is used to read or set the Module Clock Source. This variable must be system when uas7616SysTimingGen is set to none. Any of the three selections… |
| 1.3.6.1.4.1.498.12.4.5.1.11 | Columnuas7616ResetMajorAlarm | read-write | mandatory | This variable is used to reset alarm per Loop basis. |
| 1.3.6.1.4.1.498.12.4.5.1.12 | Columnuas7616ResetMinorAlarm | read-write | mandatory | This variable is used to reset alarm per Loop basis. |
| 1.3.6.1.4.1.498.12.4.6 | Tableuas7616DiagnosticTable | not-accessible | mandatory | The GDC 7616 diagnostics table. |
| 1.3.6.1.4.1.498.12.4.6.1 | Rowuas7616DiagnosticEntry | not-accessible | mandatory | A listing of GDC 7616 diagnostic tests |
| 1.3.6.1.4.1.498.12.4.6.1.1 | Columnuas7616DiagnosticIndex | read-only | mandatory | A unique index for the Diagnostic Table. |
| 1.3.6.1.4.1.498.12.4.6.1.2 | Columnuas7616DiagnosticChnlIndex | read-only | mandatory | A unique channel index for the Channel the test will run on. |
| 1.3.6.1.4.1.498.12.4.6.1.3 | Columnuas7616DiagnosticTest | read-write | mandatory | Selections digitalLoopback(2), patternGenTest(3), and unitTest(4) start the associated test when written. Reading will show which (if any) test is active. Writ… |
| 1.3.6.1.4.1.498.12.4.6.1.4 | Columnuas7616DiagnosticResetErrorCount | read-write | mandatory | This function resets the error count on a given loop and channel. Management will always read a norm(1) and can only write a reset(2). |
| 1.3.6.1.4.1.498.12.4.6.1.5 | Columnuas7616DiagnosticResults | read-only | mandatory | This function reads the self test results in bit errors. 2^20 |
| 1.3.6.1.4.1.498.12.4.8 | Tableuas7616Current15MinTable | not-accessible | mandatory | The 7616 15 Min Current table. |
| 1.3.6.1.4.1.498.12.4.8.1 | Rowuas7616Current15MinEntry | not-accessible | mandatory | An entry in the 7616 Current table. |
| 1.3.6.1.4.1.498.12.4.8.1.1 | Columnuas7616Current15MinIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.4.8.1.2 | Columnuas7616Current15MinStat | read-only | mandatory | Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit… |
| 1.3.6.1.4.1.498.12.4.9 | Tableuas7616IntervalTable | not-accessible | mandatory | The 7616 Interval table. |
| 1.3.6.1.4.1.498.12.4.9.1 | Rowuas7616IntervalEntry | not-accessible | mandatory | An entry in the Interval table. |
| 1.3.6.1.4.1.498.12.4.9.1.1 | Columnuas7616IntervalIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.4.9.1.2 | Columnuas7616IntervalNumber | read-only | mandatory | The number of Errored Seconds, Unavailable Seconds & Severely Errored Seconds encountered in one of the previous 16, individual 15 minute, intervals. |
| 1.3.6.1.4.1.498.12.4.9.1.3 | Columnuas7616IntervalStat | read-only | mandatory | Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future u… |
| 1.3.6.1.4.1.498.12.4.10 | Tableuas7616Current24HrTable | not-accessible | mandatory | The Current24Hr table. 4 hour interval. |
| 1.3.6.1.4.1.498.12.4.10.1 | Rowuas7616Current24HrEntry | not-accessible | mandatory | An entry in the Current24Hr table. |
| 1.3.6.1.4.1.498.12.4.10.1.1 | Columnuas7616Current24HrIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.4.10.1.2 | Columnuas7616Current24HrStat | read-only | mandatory | Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit… |
| 1.3.6.1.4.1.498.12.4.11 | Tableuas7616Recent24HrTable | not-accessible | mandatory | The Recent24Hr table. 4 hour interval. |
| 1.3.6.1.4.1.498.12.4.11.1 | Rowuas7616Recent24HrEntry | not-accessible | mandatory | An entry in the Recent24Hr table. |
| 1.3.6.1.4.1.498.12.4.11.1.1 | Columnuas7616Recent24HrIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.4.11.1.2 | Columnuas7616Recent24HrStat | read-only | mandatory | Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit… |
| 1.3.6.1.4.1.498.12.4.12 | Tableuas7616UnavailableTimeRegTable | not-accessible | mandatory | The 7616 Unavailable Time Register table. |
| 1.3.6.1.4.1.498.12.4.12.1 | Rowuas7616UnavailableTimeRegEntry | not-accessible | mandatory | An entry in the Unavailable Time Register table. |
| 1.3.6.1.4.1.498.12.4.12.1.1 | Columnuas7616UnavailableTimeRegIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.4.12.1.2 | Columnuas7616UnavailableTimeRegNumber | read-only | mandatory | A number between 1 and 6, where the number is the number of the Unavailable Time Register. |
| 1.3.6.1.4.1.498.12.4.12.1.3 | Columnuas7616UnavailableTimeRegStart | read-only | mandatory | Start time of one of the Unavailable Time Registers. |
| 1.3.6.1.4.1.498.12.4.12.1.4 | Columnuas7616UnavailableTimeRegStop | read-only | mandatory | Stop time of one of the Unavailable Time Registers. |
| 1.3.6.1.4.1.498.12.4.13 | Tableuas7616IntervalMaintenanceTable | not-accessible | mandatory | The 7616 Loop Interval Maintenance table. |
| 1.3.6.1.4.1.498.12.4.13.1 | Rowuas7616IntervalMaintenanceEntry | not-accessible | mandatory | The 7616 Interval Maintenance table entry. |
| 1.3.6.1.4.1.498.12.4.13.1.1 | Columnuas7616IntervalMaintenanceIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.4.13.1.2 | Columnuas7616NumberofValidIntervals | read-only | mandatory | This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes. |
| 1.3.6.1.4.1.498.12.4.14 | Tableuas7616LocalAlarmConfigTable | not-accessible | mandatory | The 7616LocalAlarmConfigTable contains entries that configure alarm reporting. |
| 1.3.6.1.4.1.498.12.4.14.1 | Rowuas7616LocalAlarmConfigEntry | not-accessible | mandatory | An entry in the GDC Local Alarm Configuration table. |
| 1.3.6.1.4.1.498.12.4.14.1.1 | Columnuas7616LocalAlarmConfigIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.4.14.1.2 | Columnuas7616LocalLossOfClock | read-write | mandatory | Disables or enables the Loss of Clock alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.3 | Columnuas7616LocalUAS | read-write | mandatory | Disables or enables the UAS alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.4 | Columnuas7616LocalSES | read-write | mandatory | Disables or enables the SES alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.5 | Columnuas7616LocalES | read-write | mandatory | Disables or enables the ES alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.6 | Columnuas7616LocalOutOfSync | read-write | mandatory | Disables or enables the Out of Sync alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.7 | Columnuas7616LocalNoSealingCurrent | read-write | mandatory | Disables or enables the No Sealing Current alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.8 | Columnuas7616LPMajor | read-write | mandatory | Disables or enables the Major alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.14.1.9 | Columnuas7616LPMinor | read-write | mandatory | Disables or enables the Minor alarm on the Minor buss or Minor buss. |
| 1.3.6.1.4.1.498.12.4.15 | Tableuas7616TSAssignTable | not-accessible | mandatory | The 7616TSAssignTable contains entries that provide a means to assign a highway and time slot of that highway to the channel of a loop. |
| 1.3.6.1.4.1.498.12.4.15.1 | Rowuas7616TSAssignEntry | not-accessible | mandatory | An entry in the GDC Circuit Identification table. |
| 1.3.6.1.4.1.498.12.4.15.1.1 | Columnuas7616TSAssignIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.4.15.1.2 | Columnuas7616ChannelIndex | read-write | mandatory | The index value which uniquely identifies the channel of the interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.4.15.1.3 | Columnuas7616Highway | read-write | mandatory | Defines the highway the channel of the loop is assigned to. |
| 1.3.6.1.4.1.498.12.4.15.1.4 | Columnuas7616TimeSlot | read-write | mandatory | Defines the time slot of the highway the channel of the loop is assigned to. Valid range is 1 to 31. A value of 64 indicates the channel is not assigned to a h… |
| 1.3.6.1.4.1.498.12.4.15.1.5 | Columnuas7616TSCircuitID | read-write | mandatory | Name to identify the circuit for the channel of this loop. |
| 1.3.6.1.4.1.498.12.13 | Nodeuas7616Alarm | |||
| 1.3.6.1.4.1.498.12.13.1 | Nodeuas7616AlarmData | |||
| 1.3.6.1.4.1.498.12.13.1.1 | Nodeuas7616NoResponseAlm | |||
| 1.3.6.1.4.1.498.12.13.1.2 | Nodeuas7616DiagRxErrAlm | |||
| 1.3.6.1.4.1.498.12.13.1.3 | Nodeuas7616PowerUpAlm | |||
| 1.3.6.1.4.1.498.12.13.1.4 | Nodeuas7616LossOfClockAlm | |||
| 1.3.6.1.4.1.498.12.13.1.5 | Nodeuas7616LpOutofSyncAlm | |||
| 1.3.6.1.4.1.498.12.13.1.6 | Nodeuas7616LpSealingCurrentNoContinuityAlm | |||
| 1.3.6.1.4.1.498.12.13.1.7 | Nodeuas7616LpUnavailableSecondAlm | |||
| 1.3.6.1.4.1.498.12.13.1.8 | Nodeuas7616LpSeverelyErroredSecondAlm | |||
| 1.3.6.1.4.1.498.12.13.1.9 | Nodeuas7616LpErroredSecondAlm | |||
| 1.3.6.1.4.1.498.12.13.2 | Tableuas7616AlarmConfigTable | not-accessible | mandatory | The uas7616AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit… |
| 1.3.6.1.4.1.498.12.13.2.1 | Rowuas7616AlarmConfigEntry | not-accessible | mandatory | An entry in the GDC Alarm Configuration table. |
| 1.3.6.1.4.1.498.12.13.2.1.1 | Columnuas7616AlarmConfigIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.13.2.1.2 | Columnuas7616AlarmConfigIdentifier | read-only | mandatory | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do… |
| 1.3.6.1.4.1.498.12.13.2.1.3 | Columnuas7616AlarmCountWindow | read-write | mandatory | This variable sets/reads the UAS, SES or ES alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before … |
| 1.3.6.1.4.1.498.12.13.2.1.4 | Columnuas7616AlarmCountThreshold | read-write | mandatory | This function sets/reads the UAS, SES or ES alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instanc… |
| 1.3.6.1.4.1.498.12.14 | Nodeuas7616mAlarm | |||
| 1.3.6.1.4.1.498.12.14.1 | Nodeuas7616mAlarmData | |||
| 1.3.6.1.4.1.498.12.14.1.1 | Nodeuas7616mNoResponseAlm | |||
| 1.3.6.1.4.1.498.12.14.1.2 | Nodeuas7616mDiagRxErrAlm | |||
| 1.3.6.1.4.1.498.12.14.1.3 | Nodeuas7616mPowerUpAlm | |||
| 1.3.6.1.4.1.498.12.14.1.4 | Nodeuas7616mLossOfClockAlm | |||
| 1.3.6.1.4.1.498.12.14.1.5 | Nodeuas7616mLpOutofSyncAlm | |||
| 1.3.6.1.4.1.498.12.14.1.6 | Nodeuas7616mLpSealingCurrentNoContinuityAlm | |||
| 1.3.6.1.4.1.498.12.14.1.7 | Nodeuas7616mLpUnavailableSecondAlm | |||
| 1.3.6.1.4.1.498.12.14.1.8 | Nodeuas7616mLpErroredSecondAlm | |||
| 1.3.6.1.4.1.498.12.14.1.9 | Nodeuas7616mLPMajorAlm | |||
| 1.3.6.1.4.1.498.12.14.1.10 | Nodeuas7616mLPMinorAlm | |||
| 1.3.6.1.4.1.498.12.14.2 | Tableuas7616mAlarmConfigTable | not-accessible | mandatory | The uas7616mAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a uni… |
| 1.3.6.1.4.1.498.12.14.2.1 | Rowuas7616mAlarmConfigEntry | not-accessible | mandatory | An entry in the GDC Alarm Configuration table. |
| 1.3.6.1.4.1.498.12.14.2.1.1 | Columnuas7616mAlarmConfigIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.14.2.1.2 | Columnuas7616mAlarmConfigIdentifier | read-only | mandatory | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do… |
| 1.3.6.1.4.1.498.12.14.2.1.3 | Columnuas7616mAlarmCountThreshold | read-write | mandatory | This function sets/reads the Major or Minor BER alarm threshold criteria. |