MIB Viewer

GDCMP7002-MIB

170 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498Nodegdc
1.3.6.1.4.1.498.6Nodedsx1
1.3.6.1.4.1.498.6.6Nodemp7002System
1.3.6.1.4.1.498.6.6.1Nodemp7002Version
1.3.6.1.4.1.498.6.6.1.1Scalarmp7002MIBversionread-onlymandatoryIdentifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number…
1.3.6.1.4.1.498.6.6.1.2Tablemp7002VersionTablenot-accessiblemandatory
1.3.6.1.4.1.498.6.6.1.2.1Rowmp7002VersionEntrynot-accessiblemandatoryAn entry in the GDC Mp7002System Version Table.
1.3.6.1.4.1.498.6.6.1.2.1.1Columnmp7002VersionIndexread-onlymandatoryThis object identifies Version parameters associated with the managed object.
1.3.6.1.4.1.498.6.6.1.2.1.2Columnmp7002FirmwareRevread-onlymandatory
1.3.6.1.4.1.498.6.6.1.2.1.3Columnmp7002ModelNumberread-onlymandatoryThis variable is used to determine the type of card family installed ex. MP7002.
1.3.6.1.4.1.498.6.6.1.2.1.4Columnmp7002E1xread-onlymandatoryIndicates if the E1X Cascade Interface is installed.
1.3.6.1.4.1.498.6.6.2Nodemp7002Maintenance
1.3.6.1.4.1.498.6.6.2.1Tablemp7002MaintenanceTablenot-accessiblemandatoryThe table describes the maintenance objects for the unit and references the unit interface (cc = 00).
1.3.6.1.4.1.498.6.6.2.1.1Rowmp7002MaintenanceEntrynot-accessiblemandatoryAn entry in the GDC E1 Maintenance Table.
1.3.6.1.4.1.498.6.6.2.1.1.1Columnmp7002MaintenanceLineIndexread-onlymandatoryThis object identifies Maintenance parameters associated with the managed object.
1.3.6.1.4.1.498.6.6.2.1.1.2Columnmp7002SoftResetread-writemandatorySupports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type…
1.3.6.1.4.1.498.6.6.2.1.1.3Columnmp7002SysUpTimeread-onlymandatoryThis variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MI…
1.3.6.1.4.1.498.6.6.2.1.1.4Columnmp7002DefaultInitread-writemandatoryThis is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a r…
1.3.6.1.4.1.498.6.6.2.1.1.5Columnmp7002ResetStatsread-writemandatorySupports the action of soft resetting the mp7002NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002NearEndVa…
1.3.6.1.4.1.498.6.6.2.1.1.6Columnmp7002LedStatusread-onlymandatoryReturns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - NIU bit 1 - D_I bit 0…
1.3.6.1.4.1.498.6.6.2.1.1.7Columnmp7002E1Circuitread-writemandatoryCircuit name E1 is connected to.
1.3.6.1.4.1.498.6.6.2.1.1.8Columnmp7002E1XCircuitread-writemandatoryCircuit Name E1X is connected to
1.3.6.1.4.1.498.6.6.2.1.1.9Columnmp7002TSBundle1Nameread-writemandatoryName first Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface
1.3.6.1.4.1.498.6.6.2.1.1.10Columnmp7002TSBundle2Nameread-writemandatoryName second Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface.
1.3.6.1.4.1.498.6.6.2.1.1.11Columnmp7002SetRealTimeread-writemandatoryNumber of seconds from midnight Dec 31, 1969.
1.3.6.1.4.1.498.6.6.2.1.1.12Columnmp7002AlarmStatusread-onlymandatoryReturns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NWTK_LOS bit 5 - NWTK_LOF bit 4 - NWTK_AIS bit 3 - NTWK_LCV bit 2 - TIMING LOSS bit 1 - NT…
1.3.6.1.4.1.498.6.6.2.1.1.13Columnmp7002SystemTimingGenStatusread-onlymandatoryIndicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both.
1.3.6.1.4.1.498.6.6.2.1.1.14Columnmp7002FarEndResetStatsread-writemandatorySupports the action of soft resetting the mp7002FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002FarEndVali…
1.3.6.1.4.1.498.6.6.2.1.1.15Columnmp7002NearEndStatLastInitializedread-onlymandatoryNumber of seconds from midnight Dec 31, 1969 up until mp7002NearEndValidIntervals was last initialized to zero
1.3.6.1.4.1.498.6.6.2.1.1.16Columnmp7002FarEndStatLastInitializedread-onlymandatoryNumber of seconds from midnight Dec 31, 1969 up until mp7002FarEndValidIntervals was last initialized to zero
1.3.6.1.4.1.498.6.6.3Nodemp7002Configuration
1.3.6.1.4.1.498.6.6.3.1Tablemp7002ConfigTablenot-accessiblemandatoryThe GDC E1 Configuration table.
1.3.6.1.4.1.498.6.6.3.1.1Rowmp7002ConfigEntrynot-accessiblemandatoryThe GDC E1 Configuration table entry.
1.3.6.1.4.1.498.6.6.3.1.1.1Columnmp7002ConfigIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.3.1.1.2Columnmp7002InterfaceTyperead-writemandatoryThe operating mode of the interface to be either Network Side, Drop Side or not assigned.
1.3.6.1.4.1.498.6.6.3.1.1.3Columnmp7002RcvrRangeread-writemandatorySets the receiver range to short (6dB) or long (36dB)
1.3.6.1.4.1.498.6.6.3.1.1.4Columnmp7002TransmitClockSourceread-writemandatorySets the transmit clock source.
1.3.6.1.4.1.498.6.6.3.1.1.5Columnmp7002FallbackClockSourceread-writemandatoryIdentifies the fallback transmit clock source.
1.3.6.1.4.1.498.6.6.3.1.1.6Columnmp7002FacilityDataLinkread-writemandatory
1.3.6.1.4.1.498.6.6.3.1.1.7Columnmp7002NearEndValidIntervalsread-onlymandatoryThe number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in …
1.3.6.1.4.1.498.6.6.3.1.1.8Columnmp7002FarEndValidIntervalsread-onlymandatoryThe number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in …
1.3.6.1.4.1.498.6.6.3.1.1.9Columnmp7002NetworkConnectionread-writemandatorySets whether the network interface is standby or online. This only applies to the Network Interface.
1.3.6.1.4.1.498.6.6.3.1.1.10Columnmp7002Framingread-writemandatorySet the framing for the interface. Abbreviations are as follows: CCS - common-channel signaling PCS0 - per channel signaling phase 0 PCS1 - per channel signali…
1.3.6.1.4.1.498.6.6.3.1.1.11Columnmp7002LineCodingread-writemandatorySets the line coding for the interface.
1.3.6.1.4.1.498.6.6.3.2Tablemp7002DCCConfigurationTablenot-accessiblemandatoryThe GDC DCC Configuration table. These are Diagnostic Channel configuration options.
1.3.6.1.4.1.498.6.6.3.2.1Rowmp7002DCCConfigurationEntrynot-accessiblemandatoryThe GDC Diagnostic Configuration table entry.
1.3.6.1.4.1.498.6.6.3.2.1.1Columnmp7002DCCConfigurationIndexread-onlymandatoryIndex value into the DCC Configuration table.
1.3.6.1.4.1.498.6.6.3.2.1.2Columnmp7002TimeSlotread-writemandatoryTime Slot DCC goes in
1.3.6.1.4.1.498.6.6.3.2.1.3Columnmp7002Bandwidthread-writemandatoryBandwidth to use: 8 kbps - bit 7 only 56 kbps - bits 0 - 6 64 kbps - all 8 bits
1.3.6.1.4.1.498.6.6.4Nodemp7002Diagnostics
1.3.6.1.4.1.498.6.6.4.1Tablemp7002DiagTablenot-accessiblemandatoryThe GDC E1 Diagnostics table. Information in the entries of this table support diagnostics testing via loopbacks. Diagnostics are only supported when mp7002Int…
1.3.6.1.4.1.498.6.6.4.1.1Rowmp7002DiagEntrynot-accessiblemandatoryThe GDC E1 Diagnostics table entry.
1.3.6.1.4.1.498.6.6.4.1.1.1Columnmp7002DiagIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.4.1.1.2Columnmp7002TestPatternread-writeobsoleteTest pattern for tests that use the pattern generator. The value of this object is used when mp7002DiagConfig.unitTest(5) or mp7002DiagConfig.patGenOn(6) is se…
1.3.6.1.4.1.498.6.6.4.1.1.3Columnmp7002DiagConfigread-writemandatorySelects the test to run. noLoop(1) ends the test. Interoperates with mp7002TestPattern. When unitTest(2) or patGenOn(3) is selected, the pattern in mp7002TestP…
1.3.6.1.4.1.498.6.6.4.1.1.4Columnmp7002TestLimitread-writemandatorySelects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. Default value:…
1.3.6.1.4.1.498.6.6.4.1.1.5Columnmp7002TestExecutionStatusread-onlymandatoryThis variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCom…
1.3.6.1.4.1.498.6.6.4.1.1.6Columnmp7002TestExceptionsread-onlymandatoryIndicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the valu…
1.3.6.1.4.1.498.6.6.4.1.1.7Columnmp7002TestResultsread-onlyobsoleteThe results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may be …
1.3.6.1.4.1.498.6.6.4.1.1.8Columnmp7002ResetTestResultsread-writeobsoleteResets the diagnostic error count. Not supported by MP7002 since no pattern generating tests are supported.
1.3.6.1.4.1.498.6.6.5Nodemp7002Performance
1.3.6.1.4.1.498.6.6.5.1Tablemp7002NearEndCurrent15MinTablenot-accessiblemandatoryThe mp7002 Current table.
1.3.6.1.4.1.498.6.6.5.1.1Rowmp7002NearEndCurrent15MinEntrynot-accessiblemandatoryAn entry in the mp7002 NearEnd Current table.
1.3.6.1.4.1.498.6.6.5.1.1.1Columnmp7002NearEndCurrent15MinIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.1.1.2Columnmp7002NearEndCurrent15MinStatread-onlymandatoryReturns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 …
1.3.6.1.4.1.498.6.6.5.2Tablemp7002NearEndIntervalTablenot-accessiblemandatoryThe mp7002 Interval table.
1.3.6.1.4.1.498.6.6.5.2.1Rowmp7002NearEndIntervalEntrynot-accessiblemandatoryAn entry in the E1 Interval table.
1.3.6.1.4.1.498.6.6.5.2.1.1Columnmp7002NearEndIntervalIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.2.1.2Columnmp7002NearEndIntervalNumberread-onlymandatoryThe number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals.
1.3.6.1.4.1.498.6.6.5.2.1.3Columnmp7002NearEndIntervalStatread-onlymandatoryReturns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7…
1.3.6.1.4.1.498.6.6.5.3Tablemp7002NearEndCurrent24HrTablenot-accessiblemandatoryThe E1 Current24Hr table. 4 hour interval.
1.3.6.1.4.1.498.6.6.5.3.1Rowmp7002NearEndCurrent24HrEntrynot-accessiblemandatoryAn entry in the E1 Total table.
1.3.6.1.4.1.498.6.6.5.3.1.1Columnmp7002NearEndCurrent24HrIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.3.1.2Columnmp7002NearEndCurrent24HrStatread-onlymandatoryReturns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^…
1.3.6.1.4.1.498.6.6.5.4Tablemp7002NearEndRecent24HrTablenot-accessiblemandatoryThe E1 Recent24Hr table. 4 hour interval.
1.3.6.1.4.1.498.6.6.5.4.1Rowmp7002NearEndRecent24HrEntrynot-accessiblemandatoryAn entry in the E1 Total table.
1.3.6.1.4.1.498.6.6.5.4.1.1Columnmp7002NearEndRecent24HrIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.4.1.2Columnmp7002NearEndRecent24HrStatread-onlymandatoryReturns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^…
1.3.6.1.4.1.498.6.6.5.5Tablemp7002FarEndCurrent15MinTablenot-accessiblemandatoryThe mp7002FarEnd Current 15 minute table.
1.3.6.1.4.1.498.6.6.5.5.1Rowmp7002FarEndCurrent15MinEntrynot-accessiblemandatoryAn entry in the mp7002FarEnd Current 15 Minute table.
1.3.6.1.4.1.498.6.6.5.5.1.1Columnmp7002FarEndCurrent15MinIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.5.1.2Columnmp7002FarEndCurrent15MinStatread-onlymandatoryReturns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES .…
1.3.6.1.4.1.498.6.6.5.6Tablemp7002FarEndIntervalTablenot-accessiblemandatoryThe mp7002FarEnd Interval table.
1.3.6.1.4.1.498.6.6.5.6.1Rowmp7002FarEndIntervalEntrynot-accessiblemandatoryAn entry in the Interval table.
1.3.6.1.4.1.498.6.6.5.6.1.1Columnmp7002FarEndIntervalIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.6.1.2Columnmp7002FarEndIntervalNumberread-onlymandatoryA number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that …
1.3.6.1.4.1.498.6.6.5.6.1.3Columnmp7002FarEndIntervalStatread-onlymandatoryReturns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2…
1.3.6.1.4.1.498.6.6.5.7Tablemp7002CurrentFarEnd24HrTablenot-accessiblemandatoryThe Current 24 Hour table.
1.3.6.1.4.1.498.6.6.5.7.1Rowmp7002CurrentFarEnd24HrEntrynot-accessiblemandatoryAn entry in the Current 24 Hr table.
1.3.6.1.4.1.498.6.6.5.7.1.1Columnmp7002CurrentFarEnd24HrIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.7.1.2Columnmp7002CurrentFarEnd24HrStatread-onlymandatoryReturns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535)…
1.3.6.1.4.1.498.6.6.5.8Tablemp7002RecentFarEnd24HrTablenot-accessiblemandatoryThe Recent 24 Hour table.
1.3.6.1.4.1.498.6.6.5.8.1Rowmp7002RecentFarEnd24HrEntrynot-accessiblemandatoryAn entry in the Recent 24 Hr table.
1.3.6.1.4.1.498.6.6.5.8.1.1Columnmp7002RecentFarEnd24HrIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.8.1.2Columnmp7002RecentFarEnd24HrStatread-onlymandatoryReturns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) …
1.3.6.1.4.1.498.6.6.5.9Tablemp7002UnavailableTimeRegTablenot-accessiblemandatoryThe mp7002 Near End Unavailable Time Register table.
1.3.6.1.4.1.498.6.6.5.9.1Rowmp7002UnavailableTimeRegEntrynot-accessiblemandatoryAn entry in the Unavailable Time Register table.
1.3.6.1.4.1.498.6.6.5.9.1.1Columnmp7002UnavailableTimeRegIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.9.1.2Columnmp7002UnavailableTimeRegNumberread-onlymandatoryA number between 1 and 6, where the number is the number of the Unavailable Time Register.
1.3.6.1.4.1.498.6.6.5.9.1.3Columnmp7002UnavailableTimeRegStartread-onlymandatoryStart time of one of the Unavailable Time Registers.
1.3.6.1.4.1.498.6.6.5.9.1.4Columnmp7002UnavailableTimeRegStopread-onlymandatoryStop time of one of the Unavailable Time Registers.
1.3.6.1.4.1.498.6.6.5.10Tablemp7002FarEndUnavailableTimeRegTablenot-accessiblemandatoryThe mp7002 Unavailable Time Register table.
1.3.6.1.4.1.498.6.6.5.10.1Rowmp7002FarEndUnavailableTimeRegEntrynot-accessiblemandatoryAn entry in the Unavailable Time Register table.
1.3.6.1.4.1.498.6.6.5.10.1.1Columnmp7002FarEndUnavailableTimeRegIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.6.6.5.10.1.2Columnmp7002FarEndUnavailableTimeRegNumberread-onlymandatoryA number between 1 and 6, where the number is the number of the Unavailable Time Register.
1.3.6.1.4.1.498.6.6.5.10.1.3Columnmp7002FarEndUnavailableTimeRegStartread-onlymandatoryStart time of one of the Unavailable Time Registers.
1.3.6.1.4.1.498.6.6.5.10.1.4Columnmp7002FarEndUnavailableTimeRegStopread-onlymandatoryStop time of one of the Unavailable Time Registers.
1.3.6.1.4.1.498.6.6.7Nodemp7002SysConfig
1.3.6.1.4.1.498.6.6.7.1Tablemp7002SysTimingTablenot-accessiblemandatoryThe GDC System Timing table. These are unit options at the system level.
1.3.6.1.4.1.498.6.6.7.1.1Rowmp7002SysTimingEntrynot-accessiblemandatoryThe GDC E1 Configuration table entry.
1.3.6.1.4.1.498.6.6.7.1.1.1Columnmp7002SysTimingIndexread-onlymandatoryIndex value into the system configuration table.
1.3.6.1.4.1.498.6.6.7.1.1.2Columnmp7002SysTimingGenread-writemandatorySelects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(…
1.3.6.1.4.1.498.6.6.7.2Tablemp7002HighwayAssignTablenot-accessiblemandatoryThe GDC System Configuration table. These are unit options at the system level.
1.3.6.1.4.1.498.6.6.7.2.1Rowmp7002HighwayAssignEntrynot-accessiblemandatoryThe GDC E1 Highway Assign table entry.
1.3.6.1.4.1.498.6.6.7.2.1.1Columnmp7002HighwayAssignIndexread-onlymandatoryIndex value into the Highway Assignment table.
1.3.6.1.4.1.498.6.6.7.2.1.2Columnmp7002TimeSlotBundleread-onlymandatoryIndex for the bundle being assigned. A time slot bundle can be assigned to 1 or 2 of the 4 backplane highways. Bundle 1 is asigned in the Aggregate starting at…
1.3.6.1.4.1.498.6.6.7.2.1.3Columnmp7002StartTimeSlotread-writemandatoryStarting time slot of the bundle. If only 1 bundle is being assigned, or the first of 2 is being assigned, it must start at 1. The second of 2 must start at th…
1.3.6.1.4.1.498.6.6.7.2.1.4Columnmp7002NumberOfTimeSlotsread-writemandatoryNumber of time slots assigned to the bundle.
1.3.6.1.4.1.498.6.6.7.2.1.5Columnmp7002BundleDestinationread-writemandatoryDefines the destination of the bundle.
1.3.6.1.4.1.498.6.6.7.2.1.6Columnmp7002ExecuteAssignread-writemandatoryCauses the MP7002 to execute configuration of the assigned highway configuration. This object should be sent in a separate PDU after acknowlegement of the assi…
1.3.6.1.4.1.498.6.9Nodemp7002Alarms
1.3.6.1.4.1.498.6.9.1Nodemp7002AlarmData
1.3.6.1.4.1.498.6.9.1.1Nodemp7002NoResponseAlm
1.3.6.1.4.1.498.6.9.1.2Nodemp7002DiagRxErrAlm
1.3.6.1.4.1.498.6.9.1.3Nodemp7002PowerUpAlm
1.3.6.1.4.1.498.6.9.1.4Nodemp7002NvRamCorrupt
1.3.6.1.4.1.498.6.9.1.5Nodemp7002UnitFailure
1.3.6.1.4.1.498.6.9.1.6Nodemp7002TimingLoss
1.3.6.1.4.1.498.6.9.1.7Nodemp7002LCV
1.3.6.1.4.1.498.6.9.1.8Nodemp7002LossOfSignal
1.3.6.1.4.1.498.6.9.1.9Nodemp7002LossOfFrame
1.3.6.1.4.1.498.6.9.1.10Nodemp7002AlarmIndSignal
1.3.6.1.4.1.498.6.9.1.11Nodemp7002NEES
1.3.6.1.4.1.498.6.9.1.12Nodemp7002NEBBE
1.3.6.1.4.1.498.6.9.1.13Nodemp7002NESES
1.3.6.1.4.1.498.6.9.1.14Nodemp7002NEUAS
1.3.6.1.4.1.498.6.9.1.15Nodemp7002FEES
1.3.6.1.4.1.498.6.9.1.16Nodemp7002FEBBE
1.3.6.1.4.1.498.6.9.1.17Nodemp7002FESES
1.3.6.1.4.1.498.6.9.1.18Nodemp7002FEUAS
1.3.6.1.4.1.498.6.9.1.19Nodemp7002RAI
1.3.6.1.4.1.498.6.9.2Tablemp7002NearEndAlarmConfigTablenot-accessiblemandatoryThe mp7002NearEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on …
1.3.6.1.4.1.498.6.9.2.1Rowmp7002NearEndAlarmConfigEntrynot-accessiblemandatoryAn entry in the MP7002 Alarm Configuration table.
1.3.6.1.4.1.498.6.9.2.1.1Columnmp7002NearEndAlarmConfigIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable.
1.3.6.1.4.1.498.6.9.2.1.2Columnmp7002NearEndAlarmConfigIdentifierread-onlymandatoryThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do…
1.3.6.1.4.1.498.6.9.2.1.3Columnmp7002NearEndAlarmCountWindowread-writemandatoryThis variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Defa…
1.3.6.1.4.1.498.6.9.2.1.4Columnmp7002NearEndAlarmCountThresholdread-writemandatoryThis function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t…
1.3.6.1.4.1.498.6.9.3Tablemp7002FarEndAlarmConfigTablenot-accessiblemandatoryThe mp7002FarEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a…
1.3.6.1.4.1.498.6.9.3.1Rowmp7002FarEndAlarmConfigEntrynot-accessiblemandatoryAn entry in the MP7002 Alarm Configuration table.
1.3.6.1.4.1.498.6.9.3.1.1Columnmp7002FarEndAlarmConfigIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable.
1.3.6.1.4.1.498.6.9.3.1.2Columnmp7002FarEndAlarmConfigIdentifierread-onlymandatoryThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do…
1.3.6.1.4.1.498.6.9.3.1.3Columnmp7002FarEndAlarmCountWindowread-writemandatoryThis variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Defa…
1.3.6.1.4.1.498.6.9.3.1.4Columnmp7002FarEndAlarmCountThresholdread-writemandatoryThis function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t…
1.3.6.1.4.1.498.6.9.4Tablemp7002LocalAlarmConfigTablenot-accessiblemandatoryThe mp7002LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a …
1.3.6.1.4.1.498.6.9.4.1Rowmp7002LocalAlarmConfigEntrynot-accessiblemandatoryAn entry in the GDC Local Alarm Configuration table.
1.3.6.1.4.1.498.6.9.4.1.1Columnmp7002LocalAlarmConfigIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable.
1.3.6.1.4.1.498.6.9.4.1.2Columnmp7002UASNEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.3Columnmp7002SESNEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.4Columnmp7002BBENEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.5Columnmp7002ESNEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.6Columnmp7002UASFEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.7Columnmp7002SESFEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.8Columnmp7002BBEFEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.9Columnmp7002ESFEread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.10Columnmp7002LOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.11Columnmp7002LOFread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.12Columnmp7002AISread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.13Columnmp7002TmgLossread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.14Columnmp7002LCVsread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.6.9.4.1.15Columnmp7002NtwkRAIread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.