GDCSC613-MIB
67 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.498 | Nodegdc | |||
| 1.3.6.1.4.1.498.12 | Nodebql2 | |||
| 1.3.6.1.4.1.498.12.1 | Nodebql613 | |||
| 1.3.6.1.4.1.498.12.1.1 | Scalarbql613MIBVersion | read-only | mandatory | The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is… |
| 1.3.6.1.4.1.498.12.1.2 | Tablebql613WhatAreYouTable | not-accessible | mandatory | The GDC SC613 What Are You Table. |
| 1.3.6.1.4.1.498.12.1.2.1 | Rowbql613WhatAreYouEntry | not-accessible | mandatory | An entry in the GDC SC613 What Are You table. |
| 1.3.6.1.4.1.498.12.1.2.1.1 | Columnbql613WhatAreYouIndex | read-only | mandatory | This object is the identifier of the SC613 What Are You table. |
| 1.3.6.1.4.1.498.12.1.2.1.2 | Columnbql613CodeRev | read-only | mandatory | This function returns the firmware code level. Example A- ,B- |
| 1.3.6.1.4.1.498.12.1.2.1.3 | Columnbql613AlarmStatus | read-only | mandatory | The current alarms of the unit without the alarm masks. |
| 1.3.6.1.4.1.498.12.1.3 | Tablebql613ConfigTable | not-accessible | mandatory | The GDC SC613. |
| 1.3.6.1.4.1.498.12.1.3.1 | Rowbql613ConfigEntry | not-accessible | mandatory | A listing of GDC 2B1Q SC613 options. |
| 1.3.6.1.4.1.498.12.1.3.1.1 | Columnbql613ConfigIndex | read-only | mandatory | A unique index for the Configuration Table. |
| 1.3.6.1.4.1.498.12.1.3.1.2 | Columnbql613TestPattern | read-write | mandatory | Object to select loop and channel test pattern for SC613. |
| 1.3.6.1.4.1.498.12.1.3.1.3 | Columnbql613RLTimeout | read-write | mandatory | Object to select remote loop time out. |
| 1.3.6.1.4.1.498.12.1.3.1.4 | Columnbql613MasterTXClkSrc | read-write | mandatory | Object to option the Loop master transmit clock source. |
| 1.3.6.1.4.1.498.12.1.3.1.5 | Columnbql613DTEDataRate | read-write | mandatory | Object to option a SC613 Loop interface to a K bit per second rate. |
| 1.3.6.1.4.1.498.12.1.3.1.6 | Columnbql613RespRdl | read-write | mandatory | Object to option V54 Response RDL to enable or disable. |
| 1.3.6.1.4.1.498.12.1.4 | Tablebql613DiagnosticTable | not-accessible | mandatory | The GDC SC613 diagnostics table. |
| 1.3.6.1.4.1.498.12.1.4.1 | Rowbql613DiagnosticEntry | not-accessible | mandatory | A listing of GDC SC613 diagnostic tests |
| 1.3.6.1.4.1.498.12.1.4.1.1 | Columnbql613DiagnosticIndex | read-only | mandatory | A unique index for the Diagnostic Table. |
| 1.3.6.1.4.1.498.12.1.4.1.2 | Columnbql613DiagnosticTest | read-write | mandatory | This function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest… |
| 1.3.6.1.4.1.498.12.1.4.1.3 | Columnbql613DiagnosticActive | read-only | mandatory | This function represents the test condition. |
| 1.3.6.1.4.1.498.12.1.4.1.4 | Columnbql613DiagnosticResults | read-only | mandatory | This function reads the self test results in bit errors. |
| 1.3.6.1.4.1.498.12.1.4.1.5 | Columnbql613DiagnosticErrorCount | read-write | mandatory | This function resets the selftest error count for a SC613. |
| 1.3.6.1.4.1.498.12.1.6 | Tablebql613ControlTable | not-accessible | mandatory | The GDC SC613 Control Table. |
| 1.3.6.1.4.1.498.12.1.6.1 | Rowbql613ControlEntry | not-accessible | mandatory | An entry in the GDC SC613 Control table. |
| 1.3.6.1.4.1.498.12.1.6.1.1 | Columnbql613ControlIndex | read-only | mandatory | This object is the identifier of the SC613 Control table. |
| 1.3.6.1.4.1.498.12.1.6.1.2 | Columnbql613SoftReset | read-write | mandatory | Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only. |
| 1.3.6.1.4.1.498.12.1.6.1.3 | Columnbql613EraseConfig | read-write | mandatory | Forces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only. |
| 1.3.6.1.4.1.498.12.1.6.1.4 | Columnbql613FrontPanel | read-write | mandatory | Object used to enable or disable the units front panel switches. |
| 1.3.6.1.4.1.498.12.1.6.1.5 | Columnbql613LEDStatus | read-only | mandatory | The GDC SC613 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - alarm on 1.4 - loop 1 line loopback … |
| 1.3.6.1.4.1.498.12.1.7 | Tablebql613CurrentTable | not-accessible | mandatory | The SC613 Current table. |
| 1.3.6.1.4.1.498.12.1.7.1 | Rowbql613CurrentEntry | not-accessible | mandatory | An entry in the SC613 Current table. |
| 1.3.6.1.4.1.498.12.1.7.1.1 | Columnbql613CurrentIndex | read-only | mandatory | The index value which uniquely identifies the SC613 interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.1.7.1.2 | Columnbql613CurrentStats | read-only | mandatory | The number of Errored Seconds, Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the current 15 minute interval. |
| 1.3.6.1.4.1.498.12.1.8 | Tablebql613IntervalTable | not-accessible | mandatory | The SC613 Interval table. |
| 1.3.6.1.4.1.498.12.1.8.1 | Rowbql613IntervalEntry | not-accessible | mandatory | An entry in the SC613 Interval table. |
| 1.3.6.1.4.1.498.12.1.8.1.1 | Columnbql613IntervalIndex | read-only | mandatory | The index value which uniquely identifies the ISDN interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.1.8.1.2 | Columnbql613IntervalNumber | read-only | mandatory | A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that… |
| 1.3.6.1.4.1.498.12.1.8.1.3 | Columnbql613IntervalStats | read-only | mandatory | The number of Errored Seconds, Severely Errored Seconds and Unavailable Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15… |
| 1.3.6.1.4.1.498.12.1.9 | Tablebql613TotalTable | not-accessible | mandatory | The SC613 Total table. 24 hour interval. |
| 1.3.6.1.4.1.498.12.1.9.1 | Rowbql613TotalEntry | not-accessible | mandatory | An entry in the SC613 Total table. |
| 1.3.6.1.4.1.498.12.1.9.1.1 | Columnbql613TotalIndex | read-only | mandatory | The index value which uniquely identifies the ISDN interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.1.9.1.2 | Columnbql613TotalStats | read-only | mandatory | The number of Errored Seconds,Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the previous 24 hour interval. |
| 1.3.6.1.4.1.498.12.1.10 | Tablebql613IntervalMaintenanceTable | not-accessible | mandatory | The SC613 Loop Interval Maintenance table. |
| 1.3.6.1.4.1.498.12.1.10.1 | Rowbql613IntervalMaintenanceEntry | not-accessible | mandatory | The SC613 Interval Maintenance table entry. |
| 1.3.6.1.4.1.498.12.1.10.1.1 | Columnbql613IntervalMaintenanceIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop… |
| 1.3.6.1.4.1.498.12.1.10.1.2 | Columnbql613ResetIntervals | read-write | mandatory | This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero. |
| 1.3.6.1.4.1.498.12.1.10.1.3 | Columnbql613NumberofValidIntervals | read-only | mandatory | This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes. |
| 1.3.6.1.4.1.498.12.1.10.1.4 | Columnbql613ResetMajorAlarm | read-write | mandatory | This variable is used to reset alarm per Loop basis. |
| 1.3.6.1.4.1.498.12.1.10.1.5 | Columnbql613ResetMinorAlarm | read-write | mandatory | This variable is used to reset alarm per Loop basis. |
| 1.3.6.1.4.1.498.12.7 | Nodebql613Alarm | |||
| 1.3.6.1.4.1.498.12.7.1 | Nodebql613AlarmData | |||
| 1.3.6.1.4.1.498.12.7.1.1 | Nodebql613NoResponseAlm | |||
| 1.3.6.1.4.1.498.12.7.1.2 | Nodebql613DiagRxErrAlm | |||
| 1.3.6.1.4.1.498.12.7.1.3 | Nodebql613PowerUpAlm | |||
| 1.3.6.1.4.1.498.12.7.1.4 | Nodebql613Lp2B1QOutofSyncAlm | |||
| 1.3.6.1.4.1.498.12.7.1.5 | Nodebql613LpTxClockOutOfTolerance | |||
| 1.3.6.1.4.1.498.12.7.1.6 | Nodebql613LpExtTxClkAlm | |||
| 1.3.6.1.4.1.498.12.7.1.7 | Nodebql613LpSealingCurrentNoContinuityAlm | |||
| 1.3.6.1.4.1.498.12.7.1.8 | Nodebql613LpMajorBERAlm | |||
| 1.3.6.1.4.1.498.12.7.1.9 | Nodebql613LpMinorBERAlm | |||
| 1.3.6.1.4.1.498.12.7.2 | Tablebql613AlarmConfigTable | not-accessible | mandatory | The bql613AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit … |
| 1.3.6.1.4.1.498.12.7.2.1 | Rowbql613AlarmConfigEntry | not-accessible | mandatory | An entry in the bql613AlarmConfigTable table. |
| 1.3.6.1.4.1.498.12.7.2.1.1 | Columnbql613AlarmConfigIndex | read-only | mandatory | The index value which uniquely identifies the interface to which this entry is applicable. |
| 1.3.6.1.4.1.498.12.7.2.1.2 | Columnbql613AlarmConfigIdentifier | read-only | mandatory | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do… |
| 1.3.6.1.4.1.498.12.7.2.1.3 | Columnbql613AlarmThreshold | read-write | mandatory | This function sets/reads the Major or Minor BER alarm threshold criteria. |