GDCUAS7022-MIB
148 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.498 | Nodegdc | |||
| 1.3.6.1.4.1.498.6 | Nodedsx1 | |||
| 1.3.6.1.4.1.498.6.13 | Nodeuas7022 | |||
| 1.3.6.1.4.1.498.6.13.1 | Nodeuas7022Version | |||
| 1.3.6.1.4.1.498.6.13.1.1 | Scalaruas7022MIBversion | read-only | mandatory | Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number… |
| 1.3.6.1.4.1.498.6.13.1.2 | Tableuas7022VersionTable | not-accessible | mandatory | The 7022 version table |
| 1.3.6.1.4.1.498.6.13.1.2.1 | Rowuas7022VersionEntry | not-accessible | mandatory | An entry in the GDC uas7022 Version Table. |
| 1.3.6.1.4.1.498.6.13.1.2.1.1 | Columnuas7022VersionIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.1.2.1.2 | Columnuas7022ActiveFirmwareRev | read-only | mandatory | The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision … |
| 1.3.6.1.4.1.498.6.13.1.2.1.3 | Columnuas7022StoredFirmwareRev | read-only | mandatory | The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix… |
| 1.3.6.1.4.1.498.6.13.1.2.1.4 | Columnuas7022StoredFirmwareStatus | read-only | mandatory | This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statO… |
| 1.3.6.1.4.1.498.6.13.1.2.1.5 | Columnuas7022SwitchActiveFirmware | read-write | mandatory | This object is used to switch the active executing firmware from the version in uas7022ActiveFirmwareRev to the version in uas7022StoredFirmwareRev. When a swi… |
| 1.3.6.1.4.1.498.6.13.1.2.1.6 | Columnuas7022DownloadingMode | read-write | mandatory | This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to UAS7022 enableAndWait(2) Allows downloading zipped code … |
| 1.3.6.1.4.1.498.6.13.2 | Nodeuas7022Maintenance | |||
| 1.3.6.1.4.1.498.6.13.2.1 | Tableuas7022MaintenanceTable | not-accessible | mandatory | The uas7022 maintenance table. |
| 1.3.6.1.4.1.498.6.13.2.1.1 | Rowuas7022MaintenanceEntry | not-accessible | mandatory | An entry in the 7022 Maintenance Table. |
| 1.3.6.1.4.1.498.6.13.2.1.1.1 | Columnuas7022MaintenanceLineIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.2.1.1.2 | Columnuas7022SoftReset | read-write | mandatory | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type… |
| 1.3.6.1.4.1.498.6.13.2.1.1.3 | Columnuas7022SysUpTime | read-only | mandatory | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MI… |
| 1.3.6.1.4.1.498.6.13.2.1.1.4 | Columnuas7022DefaultInit | read-write | mandatory | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a r… |
| 1.3.6.1.4.1.498.6.13.2.1.1.5 | Columnuas7022LedStatus | read-only | mandatory | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - future use bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - TM bit 1 - AL… |
| 1.3.6.1.4.1.498.6.13.2.1.1.6 | Columnuas7022AlarmStatus | read-only | mandatory | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NIUA_LOS bit 5 - NIUA_LOF bit 4 - NIUA_AIS bit 3 - NIUA_LCV bit 2 - NIUA TIMING LOSS bit 1… |
| 1.3.6.1.4.1.498.6.13.2.1.1.7 | Columnuas7022NearEndResetStats | read-write | mandatory | Supports the action of soft resetting the uas7022NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the uas7022NearEnd… |
| 1.3.6.1.4.1.498.6.13.2.1.1.8 | Columnuas7022FarEndResetStats | read-write | mandatory | Supports the action of soft resetting the uas7022FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the uas7022FarEndVa… |
| 1.3.6.1.4.1.498.6.13.2.1.1.9 | Columnuas7022NearEndStatLastInit | read-only | mandatory | Number of seconds from midnight Dec 31, 1969 up until uas7022NearEndValidIntervals was last initialized to zero Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.2.1.1.10 | Columnuas7022FarEndStatLastInit | read-only | mandatory | Number of seconds from midnight Dec 31, 1969 up until uas7022FarEndValidIntervals was last initialized to zero Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.2.1.1.11 | Columnuas7022NearEndValidIntervals | read-only | mandatory | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in … |
| 1.3.6.1.4.1.498.6.13.2.1.1.12 | Columnuas7022FarEndValidIntervals | read-only | mandatory | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in … |
| 1.3.6.1.4.1.498.6.13.2.1.1.13 | Columnuas7022NIUaCircuitID | read-write | mandatory | This variable is used for general purpose storage. Valid [i]nterface = 1 |
| 1.3.6.1.4.1.498.6.13.2.1.1.14 | Columnuas7022SystemTimingGenStatus | read-only | mandatory | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both. Valid [i]nterface = … |
| 1.3.6.1.4.1.498.6.13.2.1.1.15 | Columnuas7022NIUbCircuitID | read-write | mandatory | This variable is used for general purpose storage. Valid [i]nterface = 2 |
| 1.3.6.1.4.1.498.6.13.3 | Nodeuas7022Configuration | |||
| 1.3.6.1.4.1.498.6.13.3.1 | Tableuas7022ConfigTable | not-accessible | mandatory | The Configuration table. |
| 1.3.6.1.4.1.498.6.13.3.1.1 | Rowuas7022ConfigEntry | not-accessible | mandatory | The Configuration table entry. |
| 1.3.6.1.4.1.498.6.13.3.1.1.1 | Columnuas7022ConfigIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.3.1.1.2 | Columnuas7022RcvrRange | read-write | mandatory | Sets the receiver range to short (6dB) or long (36dB) Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.3 | Columnuas7022Framing | read-write | mandatory | Set the framing for the interface. Abbreviations are as follows: CCS - common-channel signaling CAS - channel-associated signaling Default is CAS If uas7022Fra… |
| 1.3.6.1.4.1.498.6.13.3.1.1.4 | Columnuas7022SysTimingGen | read-write | mandatory | Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(… |
| 1.3.6.1.4.1.498.6.13.3.1.1.5 | Columnuas7022Highway | read-write | mandatory | Defines the highway allocation. No two NIU interfaces in the shelf can be assigned to the same highway. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.6 | Columnuas7022TransmitClockSource | read-write | mandatory | Sets the transmit clock source. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.7 | Columnuas7022FallbackClockSource | read-write | mandatory | Identifies the fallback transmit clock source. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.8 | Columnuas7022InterfaceType | read-write | mandatory | Sets the interface type. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.9 | Columnuas7022FDLMode | read-write | mandatory | Sets the interface type. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.10 | Columnuas7022TimeSlot16Content | read-write | mandatory | Selects the content for TimeSlot 16. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.3.1.1.11 | Columnuas7022Impedance | read-write | mandatory | Selects the impedance. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.4 | Nodeuas7022Diagnostics | |||
| 1.3.6.1.4.1.498.6.13.4.1 | Tableuas7022DiagTable | not-accessible | mandatory | The Diagnostics table. Information in the entries of this table support diagnostics testing via loopbacks. |
| 1.3.6.1.4.1.498.6.13.4.1.1 | Rowuas7022DiagEntry | not-accessible | mandatory | The Diagnostics table entry. |
| 1.3.6.1.4.1.498.6.13.4.1.1.1 | Columnuas7022DiagIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.4.1.1.2 | Columnuas7022DiagConfig | read-write | mandatory | Selects the test to run. noLoop(1) ends the test. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.4.1.1.3 | Columnuas7022TestLimit | read-write | mandatory | Selects the duration to run a diagnostic test. The value noLimit(3) signifies that the test should run indefinitely until explicitly terminated. Default value:… |
| 1.3.6.1.4.1.498.6.13.4.1.1.4 | Columnuas7022TestExecutionStatus | read-only | mandatory | This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCom… |
| 1.3.6.1.4.1.498.6.13.4.1.1.5 | Columnuas7022TestExceptions | read-only | mandatory | Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the valu… |
| 1.3.6.1.4.1.498.6.13.5 | Nodeuas7022Performance | |||
| 1.3.6.1.4.1.498.6.13.5.1 | Tableuas7022NearEndCurrent15MinTable | not-accessible | mandatory | The uas7022 Near End Current table. |
| 1.3.6.1.4.1.498.6.13.5.1.1 | Rowuas7022NearEndCurrent15MinEntry | not-accessible | mandatory | An entry in the uas7022 Near End Current table. |
| 1.3.6.1.4.1.498.6.13.5.1.1.1 | Columnuas7022NearEndCurrent15MinIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.1.1.2 | Columnuas7022NearEndCurrent15MinStat | read-only | mandatory | Returns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 … |
| 1.3.6.1.4.1.498.6.13.5.2 | Tableuas7022NearEndIntervalTable | not-accessible | mandatory | The uas7022 Near End Interval table. |
| 1.3.6.1.4.1.498.6.13.5.2.1 | Rowuas7022NearEndIntervalEntry | not-accessible | mandatory | An entry in the Near End Interval table. |
| 1.3.6.1.4.1.498.6.13.5.2.1.1 | Columnuas7022NearEndIntervalIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.2.1.2 | Columnuas7022NearEndIntervalNumber | read-only | mandatory | The number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals. |
| 1.3.6.1.4.1.498.6.13.5.2.1.3 | Columnuas7022NearEndIntervalStat | read-only | mandatory | Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7… |
| 1.3.6.1.4.1.498.6.13.5.3 | Tableuas7022NearEndCurrent24HrTable | not-accessible | mandatory | The Near End Current 24 Hr table. |
| 1.3.6.1.4.1.498.6.13.5.3.1 | Rowuas7022NearEndCurrent24HrEntry | not-accessible | mandatory | An entry in the Near End Current 24 hr table. |
| 1.3.6.1.4.1.498.6.13.5.3.1.1 | Columnuas7022NearEndCurrent24HrIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.3.1.2 | Columnuas7022NearEndCurrent24HrStat | read-only | mandatory | Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^… |
| 1.3.6.1.4.1.498.6.13.5.4 | Tableuas7022NearEndRecent24HrTable | not-accessible | mandatory | The Near End Recent 24Hr table. |
| 1.3.6.1.4.1.498.6.13.5.4.1 | Rowuas7022NearEndRecent24HrEntry | not-accessible | mandatory | An entry in the E1 Total table. |
| 1.3.6.1.4.1.498.6.13.5.4.1.1 | Columnuas7022NearEndRecent24HrIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.4.1.2 | Columnuas7022NearEndRecent24HrStat | read-only | mandatory | Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^… |
| 1.3.6.1.4.1.498.6.13.5.5 | Tableuas7022FarEndCurrent15MinTable | not-accessible | mandatory | The uas7022 Far End Current 15 minute table. |
| 1.3.6.1.4.1.498.6.13.5.5.1 | Rowuas7022FarEndCurrent15MinEntry | not-accessible | mandatory | An entry in the uas7022 Far End Current 15 Minute table. |
| 1.3.6.1.4.1.498.6.13.5.5.1.1 | Columnuas7022FarEndCurrent15MinIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.5.1.2 | Columnuas7022FarEndCurrent15MinStat | read-only | mandatory | Returns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES .… |
| 1.3.6.1.4.1.498.6.13.5.6 | Tableuas7022FarEndIntervalTable | not-accessible | mandatory | The uas7022 FarEnd Interval table. |
| 1.3.6.1.4.1.498.6.13.5.6.1 | Rowuas7022FarEndIntervalEntry | not-accessible | mandatory | An entry in the Interval table. |
| 1.3.6.1.4.1.498.6.13.5.6.1.1 | Columnuas7022FarEndIntervalIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.6.1.2 | Columnuas7022FarEndIntervalNumber | read-only | mandatory | A number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that … |
| 1.3.6.1.4.1.498.6.13.5.6.1.3 | Columnuas7022FarEndIntervalStat | read-only | mandatory | Returns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2… |
| 1.3.6.1.4.1.498.6.13.5.7 | Tableuas7022FarEndCurrent24HrTable | not-accessible | mandatory | The Far End Current 24 Hour table. |
| 1.3.6.1.4.1.498.6.13.5.7.1 | Rowuas7022FarEndCurrent24HrEntry | not-accessible | mandatory | An entry in the Far End Current 24 Hr table. |
| 1.3.6.1.4.1.498.6.13.5.7.1.1 | Columnuas7022FarEndCurrent24HrIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.7.1.2 | Columnuas7022FarEndCurrent24HrStat | read-only | mandatory | Returns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535)… |
| 1.3.6.1.4.1.498.6.13.5.8 | Tableuas7022FarEndRecent24HrTable | not-accessible | mandatory | The Far End Recent 24 Hour table. |
| 1.3.6.1.4.1.498.6.13.5.8.1 | Rowuas7022FarEndRecent24HrEntry | not-accessible | mandatory | An entry in the Far End Recent 24 Hr table. |
| 1.3.6.1.4.1.498.6.13.5.8.1.1 | Columnuas7022FarEndRecent24HrIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.8.1.2 | Columnuas7022FarEndRecent24HrStat | read-only | mandatory | Returns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) … |
| 1.3.6.1.4.1.498.6.13.5.9 | Tableuas7022NearEndUnavailableTimeRegTable | not-accessible | mandatory | The uas7022 Near End Unavailable Time Register table. |
| 1.3.6.1.4.1.498.6.13.5.9.1 | Rowuas7022NearEndUnavailableTimeRegEntry | not-accessible | mandatory | An entry in the Near End Unavailable Time Register table. |
| 1.3.6.1.4.1.498.6.13.5.9.1.1 | Columnuas7022NearEndUnavailableTimeRegIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.9.1.2 | Columnuas7022NearEndUnavailableTimeRegNumber | read-only | mandatory | A number between 1 and 6, where the number is the number of the NearEndUnavailable Time Register. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.5.9.1.3 | Columnuas7022NearEndUnavailableTimeRegStart | read-only | mandatory | Start time of one of the NearEndUnavailable Time Registers. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.5.9.1.4 | Columnuas7022NearEndUnavailableTimeRegStop | read-only | mandatory | Stop time of one of the NearEndUnavailable Time Registers. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.5.10 | Tableuas7022FarEndUnavailableTimeRegTable | not-accessible | mandatory | The uas7022 Far End Unavailable Time Register table. |
| 1.3.6.1.4.1.498.6.13.5.10.1 | Rowuas7022FarEndUnavailableTimeRegEntry | not-accessible | mandatory | An entry in the Far End Unavailable Time Register table. |
| 1.3.6.1.4.1.498.6.13.5.10.1.1 | Columnuas7022FarEndUnavailableTimeRegIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.5.10.1.2 | Columnuas7022FarEndUnavailableTimeRegNumber | read-only | mandatory | A number between 1 and 6, where the number is the number of the Unavailable Time Register. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.5.10.1.3 | Columnuas7022FarEndUnavailableTimeRegStart | read-only | mandatory | Start time of one of the Unavailable Time Registers. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.5.10.1.4 | Columnuas7022FarEndUnavailableTimeRegStop | read-only | mandatory | Stop time of one of the Unavailable Time Registers. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.6 | Nodeuas7022Alarms | |||
| 1.3.6.1.4.1.498.6.13.6.1 | Nodeuas7022NoResponseAlm | |||
| 1.3.6.1.4.1.498.6.13.6.2 | Nodeuas7022DiagRxErrAlm | |||
| 1.3.6.1.4.1.498.6.13.6.3 | Nodeuas7022PowerUpAlm | |||
| 1.3.6.1.4.1.498.6.13.6.4 | Nodeuas7022TimingLoss | |||
| 1.3.6.1.4.1.498.6.13.6.5 | Nodeuas7022LCV | |||
| 1.3.6.1.4.1.498.6.13.6.6 | Nodeuas7022LossOfSignal | |||
| 1.3.6.1.4.1.498.6.13.6.7 | Nodeuas7022LossOfFrame | |||
| 1.3.6.1.4.1.498.6.13.6.8 | Nodeuas7022AlarmIndSignal | |||
| 1.3.6.1.4.1.498.6.13.6.9 | Nodeuas7022NEES | |||
| 1.3.6.1.4.1.498.6.13.6.10 | Nodeuas7022NEBBE | |||
| 1.3.6.1.4.1.498.6.13.6.11 | Nodeuas7022NESES | |||
| 1.3.6.1.4.1.498.6.13.6.12 | Nodeuas7022NEUAS | |||
| 1.3.6.1.4.1.498.6.13.6.13 | Nodeuas7022FEES | |||
| 1.3.6.1.4.1.498.6.13.6.14 | Nodeuas7022FEBBE | |||
| 1.3.6.1.4.1.498.6.13.6.15 | Nodeuas7022FESES | |||
| 1.3.6.1.4.1.498.6.13.6.16 | Nodeuas7022FEUAS | |||
| 1.3.6.1.4.1.498.6.13.6.17 | Nodeuas7022RAI | |||
| 1.3.6.1.4.1.498.6.13.7 | Nodeuas7022AlarmConfig | |||
| 1.3.6.1.4.1.498.6.13.7.1 | Tableuas7022NearEndAlarmConfigTable | not-accessible | mandatory | The uas7022NearEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on… |
| 1.3.6.1.4.1.498.6.13.7.1.1 | Rowuas7022NearEndAlarmConfigEntry | not-accessible | mandatory | An entry in the Near End Alarm Configuration table. |
| 1.3.6.1.4.1.498.6.13.7.1.1.1 | Columnuas7022NearEndAlarmConfigIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.7.1.1.2 | Columnuas7022NearEndAlarmConfigIdentifier | read-only | mandatory | format: iso.org.dod.internet.private.enterprises.gdc. dsx1.uas7022.uas7022Alarms.ALM example: 1.3.6.1.4.1.498.6.13.6.ALM where ALM = 1 for uas7022NoResponse al… |
| 1.3.6.1.4.1.498.6.13.7.1.1.3 | Columnuas7022NearEndAlarmCountWindow | read-write | mandatory | This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Defa… |
| 1.3.6.1.4.1.498.6.13.7.1.1.4 | Columnuas7022NearEndAlarmCountThreshold | read-write | mandatory | This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t… |
| 1.3.6.1.4.1.498.6.13.7.2 | Tableuas7022FarEndAlarmConfigTable | not-accessible | mandatory | The uas7022FarEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on … |
| 1.3.6.1.4.1.498.6.13.7.2.1 | Rowuas7022FarEndAlarmConfigEntry | not-accessible | mandatory | An entry in the Far End Alarm Configuration table. |
| 1.3.6.1.4.1.498.6.13.7.2.1.1 | Columnuas7022FarEndAlarmConfigIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.7.2.1.2 | Columnuas7022FarEndAlarmConfigIdentifier | read-only | mandatory | format: iso.org.dod.internet.private.enterprises.gdc. dsx1.uas7022.uas7022Alarms.ALM example: 1.3.6.1.4.1.498.6.13.6.ALM where ALM = 1 for uas7022NoResponse al… |
| 1.3.6.1.4.1.498.6.13.7.2.1.3 | Columnuas7022FarEndAlarmCountWindow | read-write | mandatory | This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Defa… |
| 1.3.6.1.4.1.498.6.13.7.2.1.4 | Columnuas7022FarEndAlarmCountThreshold | read-write | mandatory | This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t… |
| 1.3.6.1.4.1.498.6.13.7.3 | Tableuas7022LocalAlarmConfigTable | not-accessible | mandatory | The uas7022LocalAlarmConfigTable contains entries that configure alarm reporting to the alarm card. |
| 1.3.6.1.4.1.498.6.13.7.3.1 | Rowuas7022LocalAlarmConfigEntry | not-accessible | mandatory | An entry in the Local Alarm Configuration table. |
| 1.3.6.1.4.1.498.6.13.7.3.1.1 | Columnuas7022LocalAlarmConfigIndex | read-only | mandatory | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf … |
| 1.3.6.1.4.1.498.6.13.7.3.1.2 | Columnuas7022UASNE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.3 | Columnuas7022SESNE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.4 | Columnuas7022BBENE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.5 | Columnuas7022ESNE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.6 | Columnuas7022UASFE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.7 | Columnuas7022SESFE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.8 | Columnuas7022BBEFE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.9 | Columnuas7022ESFE | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.10 | Columnuas7022LOS | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.11 | Columnuas7022LOF | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.12 | Columnuas7022AIS | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.13 | Columnuas7022TmgLoss | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.14 | Columnuas7022LCVs | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |
| 1.3.6.1.4.1.498.6.13.7.3.1.15 | Columnuas7022NtwkRAI | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. Valid [i]nterface = 1-2 |