MIB Viewer

GX2HFC-MIB

72 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.1166.6.1Nodehfc
1.3.6.1.4.1.1166.6.1.1NodehfcCommon
1.3.6.1.4.1.1166.6.1.1.1TablehfcCommonTablenot-accessiblemandatoryThis table contains information on the HFC network configuration. Each manageable piece of equipment is defined by one row.
1.3.6.1.4.1.1166.6.1.1.1.1RowhfcCommonTableEntrynot-accessiblemandatoryThis list contains information about a single piece of equipment.
1.3.6.1.4.1.1166.6.1.1.1.1.1ColumnhfcCommonTableIndexread-onlymandatoryThe value of this object identifies the network element being proxied by the agent. This index will be used in corresponding HFC device group table. This index…
1.3.6.1.4.1.1166.6.1.1.1.1.2ColumnhfcUnitNameread-writemandatoryThe value of this object is the name of the network element being proxied by the agent.
1.3.6.1.4.1.1166.6.1.1.1.1.3ColumnhfcUnitTypeDescriptorPointerread-onlymandatoryThe value of this object is pointer to the type descriptor of the network element in the corresponding HFC device group table. This object is not used for GX2 …
1.3.6.1.4.1.1166.6.1.1.1.1.4ColumnhfcUnitHwVersionread-onlymandatoryThe value of this object is the hardware version of the network element being proxied by the agent.
1.3.6.1.4.1.1166.6.1.1.1.1.5ColumnhfcUnitFwVersionread-onlymandatoryThe value of this object is the firmware version of the network element being proxied by the agent.
1.3.6.1.4.1.1166.6.1.1.1.1.6ColumnhfcUnitModelNumberread-onlymandatoryThe value of this object is a unique device model name for the network element being proxied by the agent.
1.3.6.1.4.1.1166.6.1.1.1.1.7ColumnhfcUnitLocationread-writemandatoryThe value of this object is the location of the network element being proxied by the agent. The response string consistes of the Headend number, rack number an…
1.3.6.1.4.1.1166.6.1.1.1.1.8ColumnhfcUnitSerialNumberread-onlymandatoryThe value of this object is the serial number of the network element being proxied by the agent.
1.3.6.1.4.1.1166.6.1.1.1.1.9ColumnhfcUnitAdministrativeStateread-onlymandatoryThe current Adminsitrative state of the network elment is defined in ISO/IEC 10164-2.
1.3.6.1.4.1.1166.6.1.1.1.1.10ColumnhfcUnitOperationalStateread-onlymandatoryThe current Operational state of the network elment is defined in ISO/IEC 10164-2.
1.3.6.1.4.1.1166.6.1.1.1.1.11ColumnhfcUnitAlarmStatusread-onlymandatoryThe of thihs object is the current alarm state of the network elment.
1.3.6.1.4.1.1166.6.1.1.1.1.12ColumnhfcUnitAvailabilityStatusread-onlymandatoryThe of thihs object is the current Availability state of the network elment.
1.3.6.1.4.1.1166.6.1.1.1.1.13ColumnhfcLogicalRfNetworkDescriptorread-onlymandatoryThe value of this object is the object identifier of the descriptor containg the definition of the relationship of this network element to logical RF networks …
1.3.6.1.4.1.1166.6.1.1.1.1.14ColumnhfcUnitDetectedread-onlymandatoryThe value of this object is the date and time when the network element was detected.
1.3.6.1.4.1.1166.6.1.1.1.1.15ColumnhfcNELastTrapTimeStampread-onlymandatoryThe value of this object is the date when the network element was last updated.
1.3.6.1.4.1.1166.6.1.1.1.1.16ColumnhfcPhysicalAddressread-onlymandatoryThe value of this object is the Physical address of the network element.
1.3.6.1.4.1.1166.6.1.1.1.1.17ColumnhfcDateCoderead-onlymandatoryThe value of this object is the hardware version of the network element Date code.
1.3.6.1.4.1.1166.6.1.1.1.1.18ColumnhfcNeighbor1IPAddressread-onlymandatoryThe value of this object is the IP address of the network element Neighbor 1 - zero if not used.
1.3.6.1.4.1.1166.6.1.1.1.1.19ColumnhfcNeighbor2IPAddressread-onlymandatoryThe value of this object is the IP address of the network element Neighbor 2 - zero if not used.
1.3.6.1.4.1.1166.6.1.1.1.1.20ColumnhfcfinshedGoodsPartNumberread-onlymandatoryThe value of this object is the finshed goods part number of the network element.
1.3.6.1.4.1.1166.6.1.1.1.1.21ColumnhfcManufactureLocationread-onlymandatoryThe value of this object is the location where the network element was manufactured.
1.3.6.1.4.1.1166.6.1.1.1.1.22ColumnhfcDeviceSlotLocationread-onlymandatoryThe value of this object indicates which slot the device in plugged into.
1.3.6.1.4.1.1166.6.1.1.1.1.23ColumnhfcBelongsToread-onlymandatoryThe value of this object indicates which Control Module this device is control by. The value will be the serial number of that Control Module
1.3.6.1.4.1.1166.6.1.1.1.1.24ColumnhfcModuleTyperead-onlymandatoryThe value of this object indicates the device Model type number.
1.3.6.1.4.1.1166.6.1.1.1.1.25ColumnhfcDevicePositionDataread-onlymandatoryThe value of this object provides size and width informaton of the device. The first byte of the data indicates the number of slots the device occupies. The se…
1.3.6.1.4.1.1166.6.1.1.1.1.26ColumnhfcExtendableSlotDataread-onlymandatoryThe value of this object provides the location/side of the device. The first byte is the number of the slot the device occupies. The second byte is the depth o…
1.3.6.1.4.1.1166.6.1.1.1.1.27ColumnhfcActualModelNumberread-onlymandatoryThe value of this object is the actual device model name for the network element being proxied by the agent.
1.3.6.1.4.1.1166.6.1.2NodehfcDevices
1.3.6.1.4.1.1166.6.1.2.1Nodegx2
1.3.6.1.4.1.1166.6.1.2.1.1NodetrapHfcNewNEFoundThis trap is isssued if a Proxy Agent Detected A New NE. trapPerceivedSeverity - 'indeterminate' trapChangedObjectId - This points to the entry in the HFC comm…
1.3.6.1.4.1.1166.6.1.2.1.2NodetrapHfcNewNELostThis trap is isssued if a Proxy Agent lost communication with NE. trapPerceivedSeverity - 'critical' trapChangedObjectId - This points to the entry in the HFC …
1.3.6.1.4.1.1166.6.1.2.1.3NodetrapToBeSendQueueOverflowThis trap is issued if SNMP agent's TrapToBeSendQueue is full. trapPerceivedSeverity - 'major' trapNetworkElemModelNumber - Model # of the Agent trapNetworkEle…
1.3.6.1.4.1.1166.6.1.2.1.4NodetrapHfcNameChangeThis trap is isssued when an element name has changed.
1.3.6.1.4.1.1166.6.1.2.2NodehfcUnknownType
1.3.6.1.4.1.1166.6.1.2.3Nodegx2Cm
1.3.6.1.4.1.1166.6.1.2.4Nodegx2Lm
1.3.6.1.4.1.1166.6.1.2.5Nodegx2Lmc
1.3.6.1.4.1.1166.6.1.2.6Nodegx2Rx200
1.3.6.1.4.1.1166.6.1.2.7Nodegx2Psdc
1.3.6.1.4.1.1166.6.1.2.8Nodegx2Rsw200
1.3.6.1.4.1.1166.6.1.2.9Nodegx2Rx1000
1.3.6.1.4.1.1166.6.1.2.10Nodegx2Lm870C
1.3.6.1.4.1.1166.6.1.2.11Nodegx2EDFA
1.3.6.1.4.1.1166.6.1.2.12Nodegx2Em870
1.3.6.1.4.1.1166.6.1.2.13Nodegx2Drr3x
1.3.6.1.4.1.1166.6.1.2.14Nodegx2Drr4x
1.3.6.1.4.1.1166.6.1.2.15Nodegx2Osw10b
1.3.6.1.4.1.1166.6.1.2.16Nodegx2Dm870
1.3.6.1.4.1.1166.6.1.2.17Nodegx2OA100BD
1.3.6.1.4.1.1166.6.1.2.18Nodegx2Rsw1000b
1.3.6.1.4.1.1166.6.1.2.19Nodegx2Dm200
1.3.6.1.4.1.1166.6.1.2.20Nodegx2CEB
1.3.6.1.4.1.1166.6.1.2.21Nodegx2Drr2x
1.3.6.1.4.1.1166.6.1.2.22Nodegx2Rfa1000
1.3.6.1.4.1.1166.6.1.2.23Nodegx2Liteps
1.3.6.1.4.1.1166.6.1.2.24Nodegx2Em870x2
1.3.6.1.4.1.1166.6.1.2.25Nodegx2Drt4x
1.3.6.1.4.1.1166.6.1.2.26Nodegx2Drt2x
1.3.6.1.4.1.1166.6.1.2.27Nodegx2LmE
1.3.6.1.4.1.1166.6.1.2.28Nodegx2Dm1000
1.3.6.1.4.1.1166.6.1.2.29Nodegx2Rx200BX4
1.3.6.1.4.1.1166.6.1.2.30Nodegx2Em1000
1.3.6.1.4.1.1166.6.1.2.31Nodegx2Lm1000s
1.3.6.1.4.1.1166.6.1.2.32Nodegx2Rx085BX4
1.3.6.1.4.1.1166.6.1.2.33Nodegx2Ea1000
1.3.6.1.4.1.1166.6.1.2.34Nodegx2Dm2000
1.3.6.1.4.1.1166.6.1.2.35Nodegx2DualDrr2x
1.3.6.1.4.1.1166.6.1.2.36Nodegx2Gs1000