Redundancy group is concerned with ensuring minimal disruption to data and control planes in case of a failover. If one of the group-node in an IRF fails, the other group-node in the IRF takes over the function of the failed group-node with minimal service interruption. This module defines the objects pertaining to redundancy group(RDDC).
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.10.2.151Identityh3cRddcRedundancy group is concerned with ensuring minimal disruption to data and control planes in case of a failover. If one of the group-node in an IRF fails, the …
1.3.6.1.4.1.2011.10.2.151.0Nodeh3cRddcNotifications
1.3.6.1.4.1.2011.10.2.151.0.1Notificationh3cRddcSwitchoverTrapcurrentNotification to signal switchover/failover.
1.3.6.1.4.1.2011.10.2.151.0.2Notificationh3cRddcFailIfRecoverTrapcurrentNotification to signal the failed interface recovered.
1.3.6.1.4.1.2011.10.2.151.0.3Notificationh3cRddcFailIfGenerateTrapcurrentNotification to signal the failed interface generated.
1.3.6.1.4.1.2011.10.2.151.1Nodeh3cRddcObjects
1.3.6.1.4.1.2011.10.2.151.1.1Nodeh3cRddcInfo
1.3.6.1.4.1.2011.10.2.151.1.1.1Tableh3cRddcTablenot-accessiblecurrentThis table describes the current status of redundancy groups.
1.3.6.1.4.1.2011.10.2.151.1.1.1.1Rowh3cRddcEntrynot-accessiblecurrentThe entry of h3cRddcEntry.
1.3.6.1.4.1.2011.10.2.151.1.1.1.1.1Columnh3cRddcGroupIdxaccessible-for-notifycurrentUnique identifier of this redundancy group. 0 is an invalid value.
1.3.6.1.4.1.2011.10.2.151.1.1.1.1.2Columnh3cRddcGroupNameread-onlycurrentUnique identifier of this redundancy group.
1.3.6.1.4.1.2011.10.2.151.1.1.1.1.3Columnh3cRddcPreempTimeRemainread-onlycurrentThe redundancy group should not switch back immediately when a failover is recovered. The preempt delay timer is started for waiting the failover became believ…
1.3.6.1.4.1.2011.10.2.151.1.1.1.1.4Columnh3cRddcPreempTimeConfigread-onlycurrentThe current preempt delay time.
1.3.6.1.4.1.2011.10.2.151.1.1.1.1.5Columnh3cRddcHoldTimeRemainread-onlycurrentTo prevent frequent switchovers of the redundancy group, the hold-down timer started to keeping in a state for a fixed time. This object contains the current r…
1.3.6.1.4.1.2011.10.2.151.1.1.1.1.6Columnh3cRddcHoldTimeConfigread-onlycurrentThe current hold-down time.
1.3.6.1.4.1.2011.10.2.151.1.1.2Tableh3cRddcNodeTablenot-accessiblecurrentThis table describes the current status of a redundancy group node.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1Rowh3cRddcNodeEntrynot-accessiblecurrentThe entry of h3cRddcNodeEntry.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.1Columnh3cRddcNodeGroupIdxnot-accessiblecurrentUnique identifier of this redundancy group. 0 is an invalid value.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.2Columnh3cRddcNodeIdnot-accessiblecurrentUnique identifier of this redundancy group node. 0 is an invalid value.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.3Columnh3cRddcNodeBindTyperead-onlycurrentThe bind type of this redundancy group node. The current version only supports binding chassis of an IRF device.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.4Columnh3cRddcNodeBindInforead-onlycurrentThe bind information of this redundancy group node. The current version only supports binding chassis of an IRF device. If the value of h3cRddcNodeBindType is …
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.5Columnh3cRddcNodePriorityread-onlycurrentThe priority of this redundancy group node. The higher the value, the greater the priority.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.6Columnh3cRddcNodeWeightread-onlycurrentThe current weight of this redundancy group node. The max value is 255.
1.3.6.1.4.1.2011.10.2.151.1.1.2.1.7Columnh3cRddcNodeStatusread-onlycurrentThe current status of this redundancy group node.
1.3.6.1.4.1.2011.10.2.151.1.2Nodeh3cRddcTrapObjects
1.3.6.1.4.1.2011.10.2.151.1.2.1Scalarh3cRddcNodeInfoaccessible-for-notifycurrentThis object contains node identification information where the switchover occurred.
1.3.6.1.4.1.2011.10.2.151.1.2.2Scalarh3cRddcSwitchReasonaccessible-for-notifycurrentThis object contains the cause for switchover.