MIB Viewer

HH3C-TRANSCEIVER-INFO-MIB

99 objects
Add hh3cTransceiverTotalTXPower and hh3cTransceiverTotalRXPower.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.25506.2.70Identityhh3cTransceiverAdd hh3cTransceiverTotalTXPower and hh3cTransceiverTotalRXPower.
1.3.6.1.4.1.25506.2.70.1Nodehh3cTransceiverInfoAdm
1.3.6.1.4.1.25506.2.70.1.1Tablehh3cTransceiverInfoTablenot-accessiblecurrentThis table shows transceiver information on an interface.
1.3.6.1.4.1.25506.2.70.1.1.1Rowhh3cTransceiverInfoEntrynot-accessiblecurrentThe entry of the hh3cTransceiverInfoTable.
1.3.6.1.4.1.25506.2.70.1.1.1.1Columnhh3cTransceiverHardwareTyperead-onlycurrentHardware type of the interface, such as SM(single mode).
1.3.6.1.4.1.25506.2.70.1.1.1.2Columnhh3cTransceiverTyperead-onlycurrentType of the interface, such as SFP/XFP/GBIC.
1.3.6.1.4.1.25506.2.70.1.1.1.3Columnhh3cTransceiverWaveLengthread-onlycurrentWave length of the interface, measured in nanometer. The unit is nm.
1.3.6.1.4.1.25506.2.70.1.1.1.4Columnhh3cTransceiverVendorNameread-onlycurrentVendor name of the interface.
1.3.6.1.4.1.25506.2.70.1.1.1.5Columnhh3cTransceiverSerialNumberread-onlycurrentSerial number of the interface.
1.3.6.1.4.1.25506.2.70.1.1.1.6Columnhh3cTransceiverFiberDiameterTyperead-onlycurrentThe diameter of the fiber, measured in micron. fiber9 - 9 micron multi-mode fiber fiber50 - 50 micron multi-mode fiber fiber625 - 62.5 micron multi-mode fiber …
1.3.6.1.4.1.25506.2.70.1.1.1.7Columnhh3cTransceiverTransferDistanceread-onlycurrentThe maximum distance which the interface can transmit, measured in meter.
1.3.6.1.4.1.25506.2.70.1.1.1.8Columnhh3cTransceiverDiagnosticread-onlycurrentIndicating the digital diagnostic monitoring function.
1.3.6.1.4.1.25506.2.70.1.1.1.9Columnhh3cTransceiverCurTXPowerread-onlycurrentIndicating the current transmitted power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.10Columnhh3cTransceiverMaxTXPowerread-onlycurrentIndicating the maximum transmitted power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.11Columnhh3cTransceiverMinTXPowerread-onlycurrentIndicating the minimum transmitted power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.12Columnhh3cTransceiverCurRXPowerread-onlycurrentIndicating the current received power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.13Columnhh3cTransceiverMaxRXPowerread-onlycurrentIndicating the maximum received power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.14Columnhh3cTransceiverMinRXPowerread-onlycurrentIndicating the minimum received power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.15Columnhh3cTransceiverTemperatureread-onlycurrentIndicating the current temperature. The unit is Celsius centigrade.
1.3.6.1.4.1.25506.2.70.1.1.1.16Columnhh3cTransceiverVoltageread-onlycurrentIndicating the current voltage. The unit is in hundredths of V
1.3.6.1.4.1.25506.2.70.1.1.1.17Columnhh3cTransceiverBiasCurrentread-onlycurrentIndicating the current bias electric current. The unit is in hundredths of mA
1.3.6.1.4.1.25506.2.70.1.1.1.18Columnhh3cTransceiverTempHiAlarmread-onlycurrentTransceiver temperature high alarm threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
1.3.6.1.4.1.25506.2.70.1.1.1.19Columnhh3cTransceiverTempLoAlarmread-onlycurrentTransceiver temperature low alarm threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
1.3.6.1.4.1.25506.2.70.1.1.1.20Columnhh3cTransceiverTempHiWarnread-onlycurrentTransceiver temperature high warning threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
1.3.6.1.4.1.25506.2.70.1.1.1.21Columnhh3cTransceiverTempLoWarnread-onlycurrentTransceiver temperature low warning threshold in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius.
1.3.6.1.4.1.25506.2.70.1.1.1.22Columnhh3cTransceiverVccHiAlarmread-onlycurrentTransceiver VCC high alarm threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
1.3.6.1.4.1.25506.2.70.1.1.1.23Columnhh3cTransceiverVccLoAlarmread-onlycurrentTransceiver VCC low alarm threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
1.3.6.1.4.1.25506.2.70.1.1.1.24Columnhh3cTransceiverVccHiWarnread-onlycurrentTransceiver VCC high warning threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
1.3.6.1.4.1.25506.2.70.1.1.1.25Columnhh3cTransceiverVccLoWarnread-onlycurrentTransceiver VCC low warning threshold in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver.
1.3.6.1.4.1.25506.2.70.1.1.1.26Columnhh3cTransceiverBiasHiAlarmread-onlycurrentTransceiver bias high alarm threshold in microamps.
1.3.6.1.4.1.25506.2.70.1.1.1.27Columnhh3cTransceiverBiasLoAlarmread-onlycurrentTransceiver bias low alarm threshold in microamps.
1.3.6.1.4.1.25506.2.70.1.1.1.28Columnhh3cTransceiverBiasHiWarnread-onlycurrentTransceiver bias high warning threshold in microamps.
1.3.6.1.4.1.25506.2.70.1.1.1.29Columnhh3cTransceiverBiasLoWarnread-onlycurrentTransceiver bias low warning threshold in microamps.
1.3.6.1.4.1.25506.2.70.1.1.1.30Columnhh3cTransceiverPwrOutHiAlarmread-onlycurrentTransceiver transmit power high alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.31Columnhh3cTransceiverPwrOutLoAlarmread-onlycurrentTransceiver transmit power low alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.32Columnhh3cTransceiverPwrOutHiWarnread-onlycurrentTransceiver transmit power high warning threshold in tenths of microwatts As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.33Columnhh3cTransceiverPwrOutLoWarnread-onlycurrentTransceiver transmit power low warning threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.34Columnhh3cTransceiverRcvPwrHiAlarmread-onlycurrentTransceiver receive power high alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.35Columnhh3cTransceiverRcvPwrLoAlarmread-onlycurrentTransceiver receive power low alarm threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.36Columnhh3cTransceiverRcvPwrHiWarnread-onlycurrentTransceiver receive power high warning threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.37Columnhh3cTransceiverRcvPwrLoWarnread-onlycurrentTransceiver receive power low warning threshold in tenths of microwatts. As an example: 10000 is 1 milliwatt.
1.3.6.1.4.1.25506.2.70.1.1.1.38Columnhh3cTransceiverErrorsread-onlycurrentBitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration m…
1.3.6.1.4.1.25506.2.70.1.1.1.39Columnhh3cTransceiverVendorOUIread-onlycurrentVendor OUI of the interface.
1.3.6.1.4.1.25506.2.70.1.1.1.40Columnhh3cTransceiverRevisionNumberread-onlycurrentRevision number of the interface.
1.3.6.1.4.1.25506.2.70.1.1.1.41Columnhh3cTransceiverFrequencyread-onlycurrentThe frequency of the current ITU channel on the connected transceiver. The unit is hundredths of THz.
1.3.6.1.4.1.25506.2.70.1.1.1.42Columnhh3cTransceiverActiveITUChannelread-writecurrentThe index of the current ITU channel on the connected transceiver. The maximum index number for the ITU channel might vary by transceiver model. The value of t…
1.3.6.1.4.1.25506.2.70.1.1.1.43Columnhh3cTransceiverCurWaveErrread-onlycurrentThe current wavelength error of the current ITU channel on the connected transceiver. The unit is thousandths of nm.
1.3.6.1.4.1.25506.2.70.1.1.1.44Columnhh3cTransceiverWaveErrHiAlarmread-onlycurrentThe high wavelength error alarm threshold of the current ITU channel on the connected transceiver. The unit is thousandths of nm.
1.3.6.1.4.1.25506.2.70.1.1.1.45Columnhh3cTransceiverWaveErrLoAlarmread-onlycurrentThe low wavelength error alarm threshold of the current ITU channel on the connected transceiver. The unit is thousandths of nm.
1.3.6.1.4.1.25506.2.70.1.1.1.46Columnhh3cTransceiverCurFreqErrread-onlycurrentThe current frequency error of the current ITU channel on the connected transceiver. The unit is tenths of GHz.
1.3.6.1.4.1.25506.2.70.1.1.1.47Columnhh3cTransceiverFreqErrHiAlarmread-onlycurrentThe high frequency error alarm threshold of the current ITU channel on the connected transceiver. The unit is tenths of GHz.
1.3.6.1.4.1.25506.2.70.1.1.1.48Columnhh3cTransceiverFreqErrLoAlarmread-onlycurrentThe low frequency error alarm threshold of the current ITU channel on the connected transceiver. The unit is tenths of GHz.
1.3.6.1.4.1.25506.2.70.1.1.1.49Columnhh3cTransceiverPartNumberread-onlycurrentPartNumber of the interface. As an example: 1110409083.
1.3.6.1.4.1.25506.2.70.1.1.1.50Columnhh3cTransceiverProductCoderead-onlycurrentProduct Code of the interface. As an example: MRC00CD.
1.3.6.1.4.1.25506.2.70.1.1.1.51Columnhh3cTransceiverOriginalSNread-onlycurrentOrginal serial number of the interface.
1.3.6.1.4.1.25506.2.70.1.1.1.52Columnhh3cTransceiverPwrOutHiAlarmDbmread-onlycurrentTransceiver transmit power high alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.53Columnhh3cTransceiverPwrOutLoAlarmDbmread-onlycurrentTransceiver transmit power low alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.54Columnhh3cTransceiverPwrOutHiWarnDbmread-onlycurrentTransceiver transmit power high warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.55Columnhh3cTransceiverPwrOutLoWarnDbmread-onlycurrentTransceiver transmit power low warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.56Columnhh3cTransceiverRcvPwrHiAlarmDbmread-onlycurrentTransceiver receive power high alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.57Columnhh3cTransceiverRcvPwrLoAlarmDbmread-onlycurrentTransceiver receive power low alarm threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.58Columnhh3cTransceiverRcvPwrHiWarnDbmread-onlycurrentTransceiver receive power high warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.59Columnhh3cTransceiverRcvPwrLoWarnDbmread-onlycurrentTransceiver receive power low warning threshold in hundredths of dBm. As an example: 100 milliwatts is 20 dBms.
1.3.6.1.4.1.25506.2.70.1.1.1.60Columnhh3cTransceiverRelySlotMfgNameread-onlycurrentVendor name of the card on which the transceiver is installed.
1.3.6.1.4.1.25506.2.70.1.1.1.61Columnhh3cTransceiverRelySlotMfgDateread-onlycurrentManufacturing date of the card on which the transceiver is installed.
1.3.6.1.4.1.25506.2.70.1.1.1.62Columnhh3cTransceiverCurrentPowerread-onlycurrentCurrent transceiver real-time power. The unit is thousandths of w.
1.3.6.1.4.1.25506.2.70.1.1.1.63Columnhh3cTransceiverMaxPowerread-onlycurrentCurrent transceiver maximum power. The unit is thousandths of w.
1.3.6.1.4.1.25506.2.70.1.1.1.64Columnhh3cTransceiverTotalTXPowerread-onlycurrentIndicating the total transmitted power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.1.1.65Columnhh3cTransceiverTotalRXPowerread-onlycurrentIndicating the total received power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.2Tablehh3cTransceiverChannelTablenot-accessiblecurrentThis table provides statistics about transceiver with multi-channel.
1.3.6.1.4.1.25506.2.70.1.2.1Rowhh3cTransceiverChannelEntrynot-accessiblecurrentThe entry of the hh3cTransceiverChannelTable.
1.3.6.1.4.1.25506.2.70.1.2.1.1Columnhh3cTransceiverChannelIndexnot-accessiblecurrentThe channel index of transceiver. Indicating one channel of the interface.
1.3.6.1.4.1.25506.2.70.1.2.1.2Columnhh3cTransceiverChannelCurTXPowerread-onlycurrentIndicating the current transmission power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.2.1.3Columnhh3cTransceiverChannelCurRXPowerread-onlycurrentIndicating the current received power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.2.1.4Columnhh3cTransceiverChannelTemperatureread-onlycurrentIndicating the current temperature. The unit is Celsius centigrade.
1.3.6.1.4.1.25506.2.70.1.2.1.5Columnhh3cTransceiverChannelBiasCurrentread-onlycurrentIndicating the current bias electric current. The unit is in hundredths of mA.
1.3.6.1.4.1.25506.2.70.1.2.1.6Columnhh3cTransceiverChannelBiasHiAmread-onlycurrentTransceiver bias high alarm threshold in microamps.
1.3.6.1.4.1.25506.2.70.1.2.1.7Columnhh3cTransceiverChannelBiasLoAmread-onlycurrentTransceiver bias low alarm threshold in microamps.
1.3.6.1.4.1.25506.2.70.1.2.1.8Columnhh3cTransceiverChannelTXPwrHiAmread-onlycurrentTransceiver transmit power high alarm threshold in tenths of microwatts.
1.3.6.1.4.1.25506.2.70.1.2.1.9Columnhh3cTransceiverChannelTXPwrLoAmread-onlycurrentTransceiver transmit power low alarm threshold in tenths of microwatts.
1.3.6.1.4.1.25506.2.70.1.2.1.10Columnhh3cTransceiverChanTXPwrHiAmDbmread-onlycurrentTransceiver transmit power high alarm threshold in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.2.1.11Columnhh3cTransceiverChanTXPwrLoAmDbmread-onlycurrentTransceiver transmit power low alarm threshold in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.3Tablehh3cTransceiverITUChanTablenot-accessiblecurrentThis table provides information about ITU channels supported on the transceiver that is connected to this interface.
1.3.6.1.4.1.25506.2.70.1.3.1Rowhh3cTransceiverITUChanEntrynot-accessiblecurrentThe entry of the hh3cTransceiverITUChanTable.
1.3.6.1.4.1.25506.2.70.1.3.1.1Columnhh3cTransceiverITUChanIdxnot-accessiblecurrentThe index of the specified ITU channel on the transceiver that is connected to this interface.
1.3.6.1.4.1.25506.2.70.1.3.1.2Columnhh3cTransceiverITUChanFreqread-onlycurrentThe frequency of the specified ITU channel on the transceiver that is connected to this interface. The unit is hundredths of THz.
1.3.6.1.4.1.25506.2.70.1.3.1.3Columnhh3cTransceiverITUChanWaveLthread-onlycurrentThe wave length of the specified ITU channel on the transceiver that is connected to this interface. The unit is pm.
1.3.6.1.4.1.25506.2.70.1.4Tablehh3cTransceiverLaneTablenot-accessiblecurrentThis table provides statistics about transceiver .
1.3.6.1.4.1.25506.2.70.1.4.1Rowhh3cTransceiverLaneEntrynot-accessiblecurrentThe entry of the hh3cTransceiverLaneTable.
1.3.6.1.4.1.25506.2.70.1.4.1.1Columnhh3cTransceiverLaneCurTxPowerread-onlycurrentIndicating the current transmitted power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.4.1.2Columnhh3cTransceiverLaneCurRxPowerread-onlycurrentIndicating the current received power. The unit is in hundredths of dBm.
1.3.6.1.4.1.25506.2.70.1.4.1.3Columnhh3cTransceiverLaneBiasCurrentread-onlycurrentIndicating the current bias electric current. The unit is in hundredths of mA.
1.3.6.1.4.1.25506.2.70.2Nodehh3cTransceiverSystemPara
1.3.6.1.4.1.25506.2.70.2.1Scalarhh3cTransceiverExtrAlarmEnableread-writecurrentEnable alarming upon detection of a third-party transceiver.
1.3.6.1.4.1.25506.2.70.2.2Scalarhh3cTransceiverCurrentTotalPowerread-onlycurrentCurrent transceivers real-time total power. The unit is thousandths of w.
1.3.6.1.4.1.25506.2.70.2.3Scalarhh3cTransceiverMaxTotalPowerread-onlycurrentCurrent transceivers maximum total power. The unit is thousandths of w.
1.3.6.1.4.1.25506.2.70.3Nodehh3cTransceiverTrap
1.3.6.1.4.1.25506.2.70.3.0Nodehh3cTransceiverTrapPrefix
1.3.6.1.4.1.25506.2.70.3.0.1Notificationhh3cTransceiverMaybeFakecurrentThe transceiver is suspected to be a counterfeit/pirated/unauthorized transceiver.