MIB Viewer

HITRON-CM-EMTA-MIB

18 objects
The MIB module to describe the Hitron eMTA private management functions.
OIDNameAccessStatusDescription
1.3.6.1.4.1.8595NodehitronMib
1.3.6.1.4.1.8595.3653NodeeMTAType
1.3.6.1.4.1.8595.3653.10IdentityhitronCMEmtaThe MIB module to describe the Hitron eMTA private management functions.
1.3.6.1.4.1.8595.3653.10.1NodehitronCMEmtaBase
1.3.6.1.4.1.8595.3653.10.1.1ScalarhtCMInhibitSwDownloadDuringCallread-writecurrentThis object controls the processing logic of software downloading requests when there are specific telephony related EMTA activities. If this object has a valu…
1.3.6.1.4.1.8595.3653.10.1.2ScalarhtCMEmtaEnableread-writecurrentThis object controls the functioning of the EMTA. When this is set to False, the EMTA will be completely disabled. For online configuration of phone-lines, ple…
1.3.6.1.4.1.8595.3653.10.1.3ScalarhtCMEmtaEuroPacketCableEnableread-writecurrentThis object controls the EuroPacketCable operation of the EMTA. When this is set to False, the EMTA will be run under PacketCable mode. When this is set to tur…
1.3.6.1.4.1.8595.3653.10.1.4ScalarhtCMEmtaProvisioningFlowread-writecurrentControl the PACM_CONFIG_PROVISION_FLOWS_SUPPORT value. 0x80 would support only security flow. 0xe0 would support basic, hybrid and security flow. The default v…
1.3.6.1.4.1.8595.3653.10.1.5ScalarhtCMEmtaConfigeHashTyperead-writecurrentControl the hash type of the eMTA's configfile.
1.3.6.1.4.1.8595.3653.10.1.8ScalarhtCMEmtaVoiceStackread-writecurrentControl the code voice stack for mixed image. The default voice stack is MGCP code. IMS code does not support temporarily. If file of voice_stack is set incorr…
1.3.6.1.4.1.8595.3653.10.1.9ScalarhtCMEmtaVoiceStackRunread-onlycurrentget current running voice stack.
1.3.6.1.4.1.8595.3653.10.2NodehitronCMEmtaMaintenance
1.3.6.1.4.1.8595.3653.10.2.1ScalarhtCMEmtaMaintenanceWindowBeginread-writecurrentThis object identifies the start of an eMTA maintenance window. A maintenance window is a period of time during which the ISP may perform network maintenance o…
1.3.6.1.4.1.8595.3653.10.2.2ScalarhtCMEmtaMaintenanceWindowDurationread-writecurrentThis object identifies the duration, in seconds, of an eMTA maintenance window. Setting the value of this object to the default value of zero will cancel the m…
1.3.6.1.4.1.8595.3653.10.2.3ScalarhtCMEmtaMaintenanceControlMaskread-writecurrentThis object identifies the bit mask to control the line voltage behavior of the eMTA in various scenarios: maintenanceOnCmReset(0) - if this bit is set to 1 it…
1.3.6.1.4.1.8595.3653.10.2.4ScalarhtCMEmtaMaintenanceQuarantineTimeoutread-writecurrentThis object identifies the length of time, in seconds, that the MTA should maintain the line voltage after any of the endpoints enters the quarantine state. If…
1.3.6.1.4.1.8595.3653.10.2.5ScalarhtCMEmtaMaintenanceDisconnectedTimeoutread-writecurrentThis object identifies the length of time, in seconds, that the MTA should maintain the line voltage after any of the endpoints is disconnected. If any of the …
1.3.6.1.4.1.8595.3653.10.2.6ScalarhtCMEmtaMaintenanceRFDisconnectTimeoutread-writecurrentThis object identifies the length of time, in seconds, that the MTA should maintain the line voltage after the RF lock with the CMTS is lost. If the MTA remain…