No module-level DESCRIPTION found.
Imported Objects
Type Definitions
NameSyntaxStatusDescription
HWDetectTypeINTEGER { normalDetect(1), fastDetect(2) }currentDetect the mode type: Fast detect and standard detect
HWDot1agCfmEgressActionFieldValueINTEGER { egrOK(1), egrDown(2), egrBlocked(3), egrVid(4), egrInvalid(255) }currentPossible values returned in the egress action field
HWDot1agCfmHighestDefectPriINTEGER { none (0), defRDICCM (1), defMACstatus (2), defRemoteCCM (3), defErrorCCM (4), defXconCCM (5) }currentAn enumerated value, equal to the contents of the variable highestDefect (20.33.9 and Table 20-1), indicating the highest-priority defect that has been present since the MEP Fault Notification Generator State Machine wa…
HWDot1agCfmIngressActionFieldValueINTEGER { ingOk(1), ingDown(2), ingBlocked(3), ingVid(4), ingInvalid(255) }currentPossible values returned in the ingress action field.
HWDot1agCfmMDLevelInteger32 (0..7)currentInteger identifying the Maintenance Domain Level (MD Level). Higher numbers correspond to higher Maintenance Domains, those with the greatest physical reach, with the highest values for customers' CFM PDUs. Lower number…
HWDot1agCfmRelayActionFieldValueINTEGER { rlyHit(1), rlyFdb(2), rlyMpdb(3), rlyInvalid(255) }currentIndicates the possible values the Relay action field can take.
HWDot3OuiOCTET STRING (SIZE (3))current24-bit Organizationally Unique Identifier. Information on OUIs can be found in IEEE 802-2001 [802-2001] Clause 9.
HWTestMessageFinishedValueINTEGER { ready(1), testing(2), finished(3), failed(4), stop(5) }currentThe five values indicates: has not run/is running/the previous test terminates normally/the previous test terminates abnormally/the previous test is interrupted (through ctrl+c or mib)
HWTestMessageSendSpeedINTEGER { oneMbps(1), fiveMbps(2) }currentTransmission rate: 1Mbps and 5Mbps.