IBM-SYSTEM-RAID-MIB
169 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2.6.159.1.1.200.1 | NodeibmSystemRaidTrap | |||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.201 | NodeibmSystemRaidNoControllers | Informational: No controllers were found in this system. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.202 | NodeibmSystemRaidControllerFail | Error: Commands not responding on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.203 | NodeibmSystemRaidDeadBattery | Error: The battery-backup cache device on Controller %d needs a new battery. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.204 | NodeibmSystemRaidDeadBatteryCache | Error: The battery-backup cache device on Controller %d is defective %d | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.205 | NodeibmSystemRaidPollingFail | Error: Background polling commands not responding on Controller %d %d | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.206 | NodeibmSystemRaidConfigFail | Error: Cannot read controller configuration. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.207 | NodeibmSystemRaidControllerAdded | Informational: Controller %d has been added to the system. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.208 | NodeibmSystemRaidControllerReplaced | Informational: Controller %d has been replaced in the system. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.209 | NodeibmSystemRaidControllerFailover | Informational: Controller %d failover detected. Passive controller is now active. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.210 | NodeibmSystemRaidControllerVersionMismatch | Warning: Controller %d version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.211 | NodeibmSystemRaidControllerBatteryOvertemp | Warning: Controller %d battery has exceeded normal operating temperature. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.215 | NodeibmSystemRAIDControllerBadStripes | Warning: One or more logical drives contain a bad stripe: Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.216 | NodeibmSystemRaidControllerBatteryTempNormal | Informational: Controller %d battery operating temperature is normal. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.217 | NodeibmSystemRaidControllerStatusChange | The status of the controller changed | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.301 | NodeibmSystemRaidLogicalDriveCritical | Warning: Logical Drive %d is Critical on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.302 | NodeibmSystemRaidLogicalDriveBlocked | Error: Logical Drive %d is Blocked on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.303 | NodeibmSystemRaidLogicalDriveOffLine | Error: Logical Drive %d is Offline on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.304 | NodeibmSystemRaidRebuildDetected | Informational: Rebuilding Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.305 | NodeibmSystemRaidRebuildComplete | Informational: Rebuild complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.306 | NodeibmSystemRaidRebuildFail | Error: Rebuild failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.307 | NodeibmSystemRaidSyncDetected | Informational: Synchronizing Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.308 | NodeibmSystemRaidSyncComplete | Informational: Synchronization complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.309 | NodeibmSystemRaidSyncFail | Error: Synchronization failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.310 | NodeibmSystemRaidMigrationDetected | Informational: Migrating Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.311 | NodeibmSystemRaidMigrationComplete | Informational: Migration complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.312 | NodeibmSystemRaidMigrationFail | Error: Migration failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.313 | NodeibmSystemRaidCompressionDetected | Informational: Compressing Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.314 | NodeibmSystemRaidCompressionComplete | Informational: Compression complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.315 | NodeibmSystemRaidcompressionFail | Error: Compression failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.316 | NodeibmSystemRaidDecompressionDetected | Informational: Decompressing Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.317 | NodeibmSystemRaidDecompressionComplete | Informational: Decompression complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.318 | NodeibmSystemRaidDecompressionFail | Error: Decompression failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.319 | NodeibmSystemRaidFlashCopyDetected | Informational: FlashCopying Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.320 | NodeibmSystemRaidFlashCopyComplete | Informational: FlashCopy complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.321 | NodeibmSystemRaidFlashCopyFail | Error: FlashCopy failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.322 | NodeibmSystemRaidArrayRebuildDetected | Informational: Rebuilding Array %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.323 | NodeibmSystemRaidArrayRebuildComplete | Informational: Rebuild complete on Array %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.324 | NodeibmSystemRaidArrayRebuildFail | Error: Rebuild failed on Array %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.325 | NodeibmSystemRaidArraySyncDetected | Informational: Synchronizing Array %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.326 | NodeibmSystemRaidArraySyncComplete | Informational: Synchronization complete on Array %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.327 | NodeibmSystemRaidArraySyncFail | Error: Synchronization failed on Array %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.328 | NodeibmSystemRaidArrayFlashCopyDetected | Informational: FlashCopying Array %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.329 | NodeibmSystemRaidArrayFlashCopyComplete | Informational: FlashCopy complete on Array %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.330 | NodeibmSystemRaidArrayFlashCopyFail | Error: FlashCopy failed on Array %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.331 | NodeibmSystemRaidLogicalDriveUnblocked | Informational: Logical Drive %d is unblocked on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.332 | NodeibmSystemRaidCompactionDetected | Informational: Compacting Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.333 | NodeibmSystemRaidCompactionComplete | Informational: Compaction complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.334 | NodeibmSystemRaidCompactionFail | Error: Compaction failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.335 | NodeibmSystemRaidExpansionDetected | Informational: Expanding Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.336 | NodeibmSystemRaidExpansionComplete | Informational: Expansion complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.337 | NodeibmSystemRaidExpansionFail | Error: Expansion failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.338 | NodeibmSystemRaidLogicalDriveCriticalPeriodic | Warning: Periodic scan found 1 or more critical logical drives on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.339 | NodeibmSystemRaidCopyBackDetected | Informational: Copy back in progress on Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.340 | NodeibmSystemRaidCopyBackComplete | Informational: Copy back complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.341 | NodeibmSystemRaidCopyBackFail | Error: Copy back failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.342 | NodeibmSystemRaidInitDetected | Informational: Initialization in progress on Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.343 | NodeibmSystemRaidInitComplete | Informational: Initialization complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.344 | NodeibmSystemRaidInitFail | Error: Initialization failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.345 | NodeibmSystemRAIDLogicalDriveOK | Informational: Logical Drive %d of Controller %d is normal. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.346 | NodeibmSystemRAIDLogicalDriveAdded | Informational: Added Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.347 | NodeibmSystemRAIDLogicalDriveRemoved | Informational: Removed Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.348 | NodeibmSystemRaidArrayFlashCopyStopped | The flashcopy operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.349 | NodeibmSystemRaidArrayRebuildStopped | The array rebuild operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.350 | NodeibmSystemRaidArrayStatusChange | The array status has changed | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.351 | NodeibmSystemRaidArraySyncStopped | The array synchronization operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.352 | NodeibmSystemRaidCompactionStopped | The compaction operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.353 | NodeibmSystemRaidCompressionStopped | The compression operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.354 | NodeibmSystemRaidCopybackStopped | The copyback operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.355 | NodeibmSystemRaidDecompressionStopped | The decompression operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.356 | NodeibmSystemRaidExpansionStopped | The expansion operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.357 | NodeibmSystemRaidFlashCopyStopped | The flashcopy operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.358 | NodeibmSystemRaidInitStopped | The initialiation operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.359 | NodeibmSystemRaidLogicalDriveStatusChange | The status of the locaical drive has changed | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.360 | NodeibmSystemRaidMigrationStopped | The migration operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.361 | NodeibmSystemRaidRebuildStopped | The rebuild operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.362 | NodeibmSystemRaidSyncStopped | The synchroniation operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.401 | NodeibmSystemRaidDefunctDrive | Error: Defunct drive on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.402 | NodeibmSystemRaidPfaDrive | Warning: PFA drive on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.403 | NodeibmSystemRaidDefunctReplaced | Informational: A drive is set to Hot-Spare on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.404 | NodeibmSystemRaidDefunctDriveFru | Error: Defunct drive (FRU Part # %d} on controller %d, channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.405 | NodeibmSystemRaidPfaDriveFru | Warning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.406 | NodeibmSystemRaidUnsupportedDrive | Warning: Unsupported physical drive found on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.407 | NodeibmSystemRaidDriveAdded | Informational: Drive added on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.408 | NodeibmSystemRaidDriveRemoved | Informational: Drive removed on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.409 | NodeibmSystemRaidDriveClearDetected | Informational: Clear in progress on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.410 | NodeibmSystemRaidDriveClearComplete | Informational: Clear complete on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.411 | NodeibmSystemRaidDriveClearFail | Error: Clear failed on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.412 | NodeibmSystemRaidDriveSyncDetected | Informational: Synchronization in progress on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.413 | NodeibmSystemRaidDriveSyncComplete | Informational: Synchronization complete on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.414 | NodeibmSystemRaidDriveSyncFail | Error: Synchronization failed on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.415 | NodeibmSystemRaidDriveVerifyDetected | Informational: Verify in progress on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.416 | NodeibmSystemRaidDriveVerifyComplete | Informational: Verify complete on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.417 | NodeibmSystemRaidDriveVerifyFail | Error: Verify failed on Controller %d, Channel %d, Device ID %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.418 | NodeibmSystemRaidDriveClearStopped | The drive clear operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.419 | NodeibmSystemRaidDriveSecureEraseStopped | The secure erase operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.420 | NodeibmSystemRaidDriveStatusChange | The drive status has changed | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.421 | NodeibmSystemRaidDriveSyncStopped | The sychronization operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.422 | NodeibmSystemRaidDriveVerifyStopped | The verify operation has stopped | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.423 | NodeibmSystemRaidSpareCreated | ibmSystemRaidSpareCreated | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.424 | NodeibmSystemRaidSpareDeleted | ibmSystemRaidSpareDeleted | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.501 | NodeibmSystemRaidEnclosureOK | Informational: Enclosure device responding on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.502 | NodeibmSystemRaidEnclosureFail | Error: Enclosure device not responding on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.503 | NodeibmSystemRaidFanOk | Informational: Enclosure fan %d on Controller %d, Channel %d is now operational. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.504 | NodeibmSystemRaidFanFail | Error: Enclosure fan %d on Controller %d, Channel %d is malfunctioning. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.505 | NodeibmSystemRaidFanInstalled | Informational: Enclosure fan %d on Controller %d, Channel %d has been installed. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.506 | NodeibmSystemRaidFanRemoved | Warning: Enclosure fan %d on Controller %d, Channel %d has been removed. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.507 | NodeibmSystemRaidTempOk | Error: Enclosure temperature is in normal range on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.508 | NodeibmSystemRaidTempFail | Error: Enclosure temperature is out of normal range on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.509 | NodeibmSystemRaidPowerSupplyOk | Informational: Enclosure power supply %d on Controller %d, Channel %d is now operational. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.510 | NodeibmSystemRaidPowerSupplyFail | Error: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.511 | NodeibmSystemRaidPowerSupplyInstalled | Informational: Enclosure power supply %d on Controller %d, Channel %d has been installed. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.512 | NodeibmSystemRaidPowerSupplyRemoved | Warning: Enclosure power supply %d on Controller %d, Channel %d has been removed. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.601 | NodeibmSystemRaidTestTrap | Informational: This is a test trap. | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1000 | NodeibmSystemRaidLsiPDFail | A physical drive has failed in a RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1003 | NodeibmSystemRaidLsiPDPartOfLDFail | A physical drive has failed in a logical drive | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1004 | NodeibmSystemRaidLsiPDPartOfLDAdd | A drive has been added to a RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1005 | NodeibmSystemRaidLsiHSPartOfLD | ibmSystemRaidLsiHSPartOfLD | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1007 | NodeibmSystemRaidLsiHSFail | A hot spare drive has failed in a RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1008 | NodeibmSystemRaidLsiPDHS | A physical drive has been made a hot spare in the RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1009 | NodeibmSystemRaidLsiLDOffline | A logical drive is in the offline state | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1011 | NodeibmSystemRaidLsiLDDegraded | A logical drive has been degraded in a RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1012 | NodeibmSystemRaidLsiLDOptimal | A logical drive is functioning correctly | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1013 | NodeibmSystemRaidLsiSMARTError | A PFA has been detected on a drive in the RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1015 | NodeibmSystemRaidLsiRbldStart | A RAID rebuild operation is in progress on an array in the RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1016 | NodeibmSystemRaidLsiRbldComplete | A RAID rebuild operation has completed on an array in the RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.1.1017 | NodeibmSystemRaidLsiRbldFail | A RAID rebuild operation has failed on an array in the RAID configuration | ||
| 1.3.6.1.4.1.2.6.159.1.1.200.2 | TableibmSystemRaidControllerTable | not-accessible | mandatory | The IBMPSG_RAIDController class represents a RAID Controller |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1 | RowibmSystemRaidControllerEntry | not-accessible | mandatory | This class defines an entry for each IBMPSG_RAIDController instance. Each instance of the IBMPSG_RAIDController class contains status and descriptive informati… |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.1 | ColumnibmSystemRaidControllerKeyIndex | read-only | mandatory | The RAID controller table index number (controller1, controller2, etc.) |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.2 | ColumnibmSystemRaidControllerControllerID | read-only | mandatory | The DeviceID that identifies the disk |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.3 | ColumnibmSystemRaidControllerModel | read-only | mandatory | The model of the controller |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.4 | ColumnibmSystemRaidControllerBIOSVersion | read-only | mandatory | The version of the controllers BIOS |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.5 | ColumnibmSystemRaidControllerFirmwareVersion | read-only | mandatory | The version of the controllers firmwar |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.6 | ColumnibmSystemRaidControllerDriverVersion | read-only | mandatory | The version of the controllers device driver |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.7 | ColumnibmSystemRaidControllerManufacturer | read-only | mandatory | the manufacturer of the controller |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.8 | ColumnibmSystemRaidControllerSlot | read-only | mandatory | The slot number the controller resides in |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.9 | ColumnibmSystemRaidControllerFRU | read-only | mandatory | The FRU number of the controller |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.10 | ColumnibmSystemRaidControllerSerialNumber | read-only | mandatory | The controllers serial number |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.11 | ColumnibmSystemRaidControllerInitiatorIDs | read-only | mandatory | Specifies the controllers initiator IDs using a comma as the delimiter |
| 1.3.6.1.4.1.2.6.159.1.1.200.2.1.12 | ColumnibmSystemRaidControllerStatus | read-only | mandatory | The current status of the controller |
| 1.3.6.1.4.1.2.6.159.1.1.200.3 | TableibmSystemRaidDiskDriveTable | not-accessible | mandatory | The IBMPSG_RAIDDiskDrive class represents a RAID physical disk |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1 | RowibmSystemRaidDiskDriveEntry | not-accessible | mandatory | This class defines an entry for each IBMPSG_RAIDDiskDrive instance. Each instance of the IBMPSG_RAIDDiskDrive class contains status and descriptive information… |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.1 | ColumnibmSystemRaidDiskDriveKeyIndex | read-only | mandatory | The Physical Disk Drive table index number (Disk Drive 0, Disk Drive 1, etc.) |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.2 | ColumnibmSystemRaidDiskDriveDeviceID | read-only | mandatory | The device ID of the drive |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.3 | ColumnibmSystemRaidDiskDriveDiskDriveID | read-only | mandatory | The target ID of the disk drive |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.4 | ColumnibmSystemRaidDiskDriveControllerID | read-only | mandatory | The ID of the controller it is attached to |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.5 | ColumnibmSystemRaidDiskDriveChannelID | read-only | mandatory | The channel on the controller the drive is attached to |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.6 | ColumnibmSystemRaidDiskDriveFirmware | read-only | mandatory | The firmware revision of the drive |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.7 | ColumnibmSystemRaidDiskDriveState | read-only | mandatory | The current state of the physical drive. 0=Empty, 1=Standby, 4=Defunct Hot Spare, 5=Standby Hot Spare, 8=Defunct Disk Drive, 129=Ready, 133=Hot Spare, 137=Onli… |
| 1.3.6.1.4.1.2.6.159.1.1.200.3.1.8 | ColumnibmSystemRaidDiskDriveStatus | read-only | mandatory | The status of the drive |
| 1.3.6.1.4.1.2.6.159.1.1.200.4 | TableibmSystemRaidLogicalDriveTable | not-accessible | mandatory | The IBMPSG_RAIDLogicalDrive class represents a RAID Logical disk (Logical Drive 0, Logical Drive 1, etc.) |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1 | RowibmSystemRaidLogicalDriveEntry | not-accessible | mandatory | This class defines an entry for each IBMPSG_RAIDLogicalDrive instance. Each instance of the IBMPSG_RAIDLogicalDrive class contains status and descriptive infor… |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.1 | ColumnibmSystemRaidLogicalDriveKeyIndex | read-only | mandatory | The Logical Disk Drive table index number (Logical Drive 0, Logical Drive 1, etc.) |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.2 | ColumnibmSystemRaidLogicalDriveLogicalDriveID | read-only | mandatory | The ID of the logical drive |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.3 | ColumnibmSystemRaidLogicalDriveControllerID | read-only | mandatory | The ID of the controller the logical drive belongs to |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.4 | ColumnibmSystemRaidLogicalDriveArrayID | read-only | mandatory | The ID of the array that the logical drive belongs to |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.5 | ColumnibmSystemRaidLogicalDriveRAIDLevel | read-only | mandatory | The RAID level of the logical drive (RAID 1, RAID 5, etc.) |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.6 | ColumnibmSystemRaidLogicalDriveDataSpace | read-only | mandatory | Size of the logical drive in megabytes |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.7 | ColumnibmSystemRaidLogicalDriveParitySpace | read-only | mandatory | Parity space of the logical drive in megabytes |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.8 | ColumnibmSystemRaidLogicalDriveIsBlocked | read-only | mandatory | The logical drive is in a blocked state |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.9 | ColumnibmSystemRaidLogicalDriveState | read-only | mandatory | The current state of the logical drive. 0=Free, 2=Offline, 3=Okay, 4=Critical, 5=Logical Drive Migration, 6=System, 20=Critical Logical Drive Migration, 36=Cri… |
| 1.3.6.1.4.1.2.6.159.1.1.200.4.1.10 | ColumnibmSystemRaidLogicalDriveStatus | read-only | mandatory | The status of the logical drive |
| 1.3.6.1.4.1.2.6.159.1.1.200.5 | NodeibmSystemRaidTrapInfo | |||
| 1.3.6.1.4.1.2.6.159.1.1.200.5.1 | ScalaribmSystemRaidTrapProviderName | not-accessible | mandatory | The CIM Provider Name |
| 1.3.6.1.4.1.2.6.159.1.1.200.5.2 | ScalaribmSystemRaidTrapEventID | not-accessible | mandatory | Event ID |
| 1.3.6.1.4.1.2.6.159.1.1.200.5.3 | ScalaribmSystemRaidTrapPerceivedSeverity | not-accessible | mandatory | Severity of the event 0=Normal / OK 1=Warning 2=Critical |
| 1.3.6.1.4.1.2.6.159.1.1.200.5.4 | ScalaribmSystemRaidDescription | not-accessible | mandatory | The event message |
| 1.3.6.1.4.1.2.6.159.1.1.200.5.5 | ScalaribmSystemRaidTrapEventTime | not-accessible | mandatory | Time that the event occured |