MIB Viewer

IBM-SYSTEM-RAID-MIB

169 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2.6.159.1.1.200.1NodeibmSystemRaidTrap
1.3.6.1.4.1.2.6.159.1.1.200.1.201NodeibmSystemRaidNoControllersInformational: No controllers were found in this system.
1.3.6.1.4.1.2.6.159.1.1.200.1.202NodeibmSystemRaidControllerFailError: Commands not responding on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.203NodeibmSystemRaidDeadBatteryError: The battery-backup cache device on Controller %d needs a new battery.
1.3.6.1.4.1.2.6.159.1.1.200.1.204NodeibmSystemRaidDeadBatteryCacheError: The battery-backup cache device on Controller %d is defective %d
1.3.6.1.4.1.2.6.159.1.1.200.1.205NodeibmSystemRaidPollingFailError: Background polling commands not responding on Controller %d %d
1.3.6.1.4.1.2.6.159.1.1.200.1.206NodeibmSystemRaidConfigFailError: Cannot read controller configuration.
1.3.6.1.4.1.2.6.159.1.1.200.1.207NodeibmSystemRaidControllerAddedInformational: Controller %d has been added to the system.
1.3.6.1.4.1.2.6.159.1.1.200.1.208NodeibmSystemRaidControllerReplacedInformational: Controller %d has been replaced in the system.
1.3.6.1.4.1.2.6.159.1.1.200.1.209NodeibmSystemRaidControllerFailoverInformational: Controller %d failover detected. Passive controller is now active.
1.3.6.1.4.1.2.6.159.1.1.200.1.210NodeibmSystemRaidControllerVersionMismatchWarning: Controller %d version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible.
1.3.6.1.4.1.2.6.159.1.1.200.1.211NodeibmSystemRaidControllerBatteryOvertempWarning: Controller %d battery has exceeded normal operating temperature.
1.3.6.1.4.1.2.6.159.1.1.200.1.215NodeibmSystemRAIDControllerBadStripesWarning: One or more logical drives contain a bad stripe: Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.216NodeibmSystemRaidControllerBatteryTempNormalInformational: Controller %d battery operating temperature is normal.
1.3.6.1.4.1.2.6.159.1.1.200.1.217NodeibmSystemRaidControllerStatusChangeThe status of the controller changed
1.3.6.1.4.1.2.6.159.1.1.200.1.301NodeibmSystemRaidLogicalDriveCriticalWarning: Logical Drive %d is Critical on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.302NodeibmSystemRaidLogicalDriveBlockedError: Logical Drive %d is Blocked on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.303NodeibmSystemRaidLogicalDriveOffLineError: Logical Drive %d is Offline on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.304NodeibmSystemRaidRebuildDetectedInformational: Rebuilding Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.305NodeibmSystemRaidRebuildCompleteInformational: Rebuild complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.306NodeibmSystemRaidRebuildFailError: Rebuild failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.307NodeibmSystemRaidSyncDetectedInformational: Synchronizing Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.308NodeibmSystemRaidSyncCompleteInformational: Synchronization complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.309NodeibmSystemRaidSyncFailError: Synchronization failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.310NodeibmSystemRaidMigrationDetectedInformational: Migrating Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.311NodeibmSystemRaidMigrationCompleteInformational: Migration complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.312NodeibmSystemRaidMigrationFailError: Migration failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.313NodeibmSystemRaidCompressionDetectedInformational: Compressing Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.314NodeibmSystemRaidCompressionCompleteInformational: Compression complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.315NodeibmSystemRaidcompressionFailError: Compression failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.316NodeibmSystemRaidDecompressionDetectedInformational: Decompressing Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.317NodeibmSystemRaidDecompressionCompleteInformational: Decompression complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.318NodeibmSystemRaidDecompressionFailError: Decompression failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.319NodeibmSystemRaidFlashCopyDetectedInformational: FlashCopying Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.320NodeibmSystemRaidFlashCopyCompleteInformational: FlashCopy complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.321NodeibmSystemRaidFlashCopyFailError: FlashCopy failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.322NodeibmSystemRaidArrayRebuildDetectedInformational: Rebuilding Array %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.323NodeibmSystemRaidArrayRebuildCompleteInformational: Rebuild complete on Array %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.324NodeibmSystemRaidArrayRebuildFailError: Rebuild failed on Array %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.325NodeibmSystemRaidArraySyncDetectedInformational: Synchronizing Array %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.326NodeibmSystemRaidArraySyncCompleteInformational: Synchronization complete on Array %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.327NodeibmSystemRaidArraySyncFailError: Synchronization failed on Array %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.328NodeibmSystemRaidArrayFlashCopyDetectedInformational: FlashCopying Array %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.329NodeibmSystemRaidArrayFlashCopyCompleteInformational: FlashCopy complete on Array %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.330NodeibmSystemRaidArrayFlashCopyFailError: FlashCopy failed on Array %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.331NodeibmSystemRaidLogicalDriveUnblockedInformational: Logical Drive %d is unblocked on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.332NodeibmSystemRaidCompactionDetectedInformational: Compacting Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.333NodeibmSystemRaidCompactionCompleteInformational: Compaction complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.334NodeibmSystemRaidCompactionFailError: Compaction failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.335NodeibmSystemRaidExpansionDetectedInformational: Expanding Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.336NodeibmSystemRaidExpansionCompleteInformational: Expansion complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.337NodeibmSystemRaidExpansionFailError: Expansion failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.338NodeibmSystemRaidLogicalDriveCriticalPeriodicWarning: Periodic scan found 1 or more critical logical drives on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.339NodeibmSystemRaidCopyBackDetectedInformational: Copy back in progress on Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.340NodeibmSystemRaidCopyBackCompleteInformational: Copy back complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.341NodeibmSystemRaidCopyBackFailError: Copy back failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.342NodeibmSystemRaidInitDetectedInformational: Initialization in progress on Logical Drive %d on Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.343NodeibmSystemRaidInitCompleteInformational: Initialization complete on Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.344NodeibmSystemRaidInitFailError: Initialization failed on Logical Drive %d of Controller %d %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.345NodeibmSystemRAIDLogicalDriveOKInformational: Logical Drive %d of Controller %d is normal.
1.3.6.1.4.1.2.6.159.1.1.200.1.346NodeibmSystemRAIDLogicalDriveAddedInformational: Added Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.347NodeibmSystemRAIDLogicalDriveRemovedInformational: Removed Logical Drive %d of Controller %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.348NodeibmSystemRaidArrayFlashCopyStoppedThe flashcopy operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.349NodeibmSystemRaidArrayRebuildStoppedThe array rebuild operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.350NodeibmSystemRaidArrayStatusChangeThe array status has changed
1.3.6.1.4.1.2.6.159.1.1.200.1.351NodeibmSystemRaidArraySyncStoppedThe array synchronization operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.352NodeibmSystemRaidCompactionStoppedThe compaction operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.353NodeibmSystemRaidCompressionStoppedThe compression operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.354NodeibmSystemRaidCopybackStoppedThe copyback operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.355NodeibmSystemRaidDecompressionStoppedThe decompression operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.356NodeibmSystemRaidExpansionStoppedThe expansion operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.357NodeibmSystemRaidFlashCopyStoppedThe flashcopy operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.358NodeibmSystemRaidInitStoppedThe initialiation operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.359NodeibmSystemRaidLogicalDriveStatusChangeThe status of the locaical drive has changed
1.3.6.1.4.1.2.6.159.1.1.200.1.360NodeibmSystemRaidMigrationStoppedThe migration operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.361NodeibmSystemRaidRebuildStoppedThe rebuild operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.362NodeibmSystemRaidSyncStoppedThe synchroniation operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.401NodeibmSystemRaidDefunctDriveError: Defunct drive on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.402NodeibmSystemRaidPfaDriveWarning: PFA drive on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.403NodeibmSystemRaidDefunctReplacedInformational: A drive is set to Hot-Spare on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.404NodeibmSystemRaidDefunctDriveFruError: Defunct drive (FRU Part # %d} on controller %d, channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.405NodeibmSystemRaidPfaDriveFruWarning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.406NodeibmSystemRaidUnsupportedDriveWarning: Unsupported physical drive found on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.407NodeibmSystemRaidDriveAddedInformational: Drive added on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.408NodeibmSystemRaidDriveRemovedInformational: Drive removed on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.409NodeibmSystemRaidDriveClearDetectedInformational: Clear in progress on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.410NodeibmSystemRaidDriveClearCompleteInformational: Clear complete on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.411NodeibmSystemRaidDriveClearFailError: Clear failed on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.412NodeibmSystemRaidDriveSyncDetectedInformational: Synchronization in progress on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.413NodeibmSystemRaidDriveSyncCompleteInformational: Synchronization complete on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.414NodeibmSystemRaidDriveSyncFailError: Synchronization failed on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.415NodeibmSystemRaidDriveVerifyDetectedInformational: Verify in progress on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.416NodeibmSystemRaidDriveVerifyCompleteInformational: Verify complete on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.417NodeibmSystemRaidDriveVerifyFailError: Verify failed on Controller %d, Channel %d, Device ID %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.418NodeibmSystemRaidDriveClearStoppedThe drive clear operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.419NodeibmSystemRaidDriveSecureEraseStoppedThe secure erase operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.420NodeibmSystemRaidDriveStatusChangeThe drive status has changed
1.3.6.1.4.1.2.6.159.1.1.200.1.421NodeibmSystemRaidDriveSyncStoppedThe sychronization operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.422NodeibmSystemRaidDriveVerifyStoppedThe verify operation has stopped
1.3.6.1.4.1.2.6.159.1.1.200.1.423NodeibmSystemRaidSpareCreatedibmSystemRaidSpareCreated
1.3.6.1.4.1.2.6.159.1.1.200.1.424NodeibmSystemRaidSpareDeletedibmSystemRaidSpareDeleted
1.3.6.1.4.1.2.6.159.1.1.200.1.501NodeibmSystemRaidEnclosureOKInformational: Enclosure device responding on Controller %d, Channel %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.502NodeibmSystemRaidEnclosureFailError: Enclosure device not responding on Controller %d, Channel %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.503NodeibmSystemRaidFanOkInformational: Enclosure fan %d on Controller %d, Channel %d is now operational.
1.3.6.1.4.1.2.6.159.1.1.200.1.504NodeibmSystemRaidFanFailError: Enclosure fan %d on Controller %d, Channel %d is malfunctioning.
1.3.6.1.4.1.2.6.159.1.1.200.1.505NodeibmSystemRaidFanInstalledInformational: Enclosure fan %d on Controller %d, Channel %d has been installed.
1.3.6.1.4.1.2.6.159.1.1.200.1.506NodeibmSystemRaidFanRemovedWarning: Enclosure fan %d on Controller %d, Channel %d has been removed.
1.3.6.1.4.1.2.6.159.1.1.200.1.507NodeibmSystemRaidTempOkError: Enclosure temperature is in normal range on Controller %d, Channel %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.508NodeibmSystemRaidTempFailError: Enclosure temperature is out of normal range on Controller %d, Channel %d.
1.3.6.1.4.1.2.6.159.1.1.200.1.509NodeibmSystemRaidPowerSupplyOkInformational: Enclosure power supply %d on Controller %d, Channel %d is now operational.
1.3.6.1.4.1.2.6.159.1.1.200.1.510NodeibmSystemRaidPowerSupplyFailError: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning.
1.3.6.1.4.1.2.6.159.1.1.200.1.511NodeibmSystemRaidPowerSupplyInstalledInformational: Enclosure power supply %d on Controller %d, Channel %d has been installed.
1.3.6.1.4.1.2.6.159.1.1.200.1.512NodeibmSystemRaidPowerSupplyRemovedWarning: Enclosure power supply %d on Controller %d, Channel %d has been removed.
1.3.6.1.4.1.2.6.159.1.1.200.1.601NodeibmSystemRaidTestTrapInformational: This is a test trap.
1.3.6.1.4.1.2.6.159.1.1.200.1.1000NodeibmSystemRaidLsiPDFailA physical drive has failed in a RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1003NodeibmSystemRaidLsiPDPartOfLDFailA physical drive has failed in a logical drive
1.3.6.1.4.1.2.6.159.1.1.200.1.1004NodeibmSystemRaidLsiPDPartOfLDAddA drive has been added to a RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1005NodeibmSystemRaidLsiHSPartOfLDibmSystemRaidLsiHSPartOfLD
1.3.6.1.4.1.2.6.159.1.1.200.1.1007NodeibmSystemRaidLsiHSFailA hot spare drive has failed in a RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1008NodeibmSystemRaidLsiPDHSA physical drive has been made a hot spare in the RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1009NodeibmSystemRaidLsiLDOfflineA logical drive is in the offline state
1.3.6.1.4.1.2.6.159.1.1.200.1.1011NodeibmSystemRaidLsiLDDegradedA logical drive has been degraded in a RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1012NodeibmSystemRaidLsiLDOptimalA logical drive is functioning correctly
1.3.6.1.4.1.2.6.159.1.1.200.1.1013NodeibmSystemRaidLsiSMARTErrorA PFA has been detected on a drive in the RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1015NodeibmSystemRaidLsiRbldStartA RAID rebuild operation is in progress on an array in the RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1016NodeibmSystemRaidLsiRbldCompleteA RAID rebuild operation has completed on an array in the RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.1.1017NodeibmSystemRaidLsiRbldFailA RAID rebuild operation has failed on an array in the RAID configuration
1.3.6.1.4.1.2.6.159.1.1.200.2TableibmSystemRaidControllerTablenot-accessiblemandatoryThe IBMPSG_RAIDController class represents a RAID Controller
1.3.6.1.4.1.2.6.159.1.1.200.2.1RowibmSystemRaidControllerEntrynot-accessiblemandatoryThis class defines an entry for each IBMPSG_RAIDController instance. Each instance of the IBMPSG_RAIDController class contains status and descriptive informati…
1.3.6.1.4.1.2.6.159.1.1.200.2.1.1ColumnibmSystemRaidControllerKeyIndexread-onlymandatoryThe RAID controller table index number (controller1, controller2, etc.)
1.3.6.1.4.1.2.6.159.1.1.200.2.1.2ColumnibmSystemRaidControllerControllerIDread-onlymandatoryThe DeviceID that identifies the disk
1.3.6.1.4.1.2.6.159.1.1.200.2.1.3ColumnibmSystemRaidControllerModelread-onlymandatoryThe model of the controller
1.3.6.1.4.1.2.6.159.1.1.200.2.1.4ColumnibmSystemRaidControllerBIOSVersionread-onlymandatoryThe version of the controllers BIOS
1.3.6.1.4.1.2.6.159.1.1.200.2.1.5ColumnibmSystemRaidControllerFirmwareVersionread-onlymandatoryThe version of the controllers firmwar
1.3.6.1.4.1.2.6.159.1.1.200.2.1.6ColumnibmSystemRaidControllerDriverVersionread-onlymandatoryThe version of the controllers device driver
1.3.6.1.4.1.2.6.159.1.1.200.2.1.7ColumnibmSystemRaidControllerManufacturerread-onlymandatorythe manufacturer of the controller
1.3.6.1.4.1.2.6.159.1.1.200.2.1.8ColumnibmSystemRaidControllerSlotread-onlymandatoryThe slot number the controller resides in
1.3.6.1.4.1.2.6.159.1.1.200.2.1.9ColumnibmSystemRaidControllerFRUread-onlymandatoryThe FRU number of the controller
1.3.6.1.4.1.2.6.159.1.1.200.2.1.10ColumnibmSystemRaidControllerSerialNumberread-onlymandatoryThe controllers serial number
1.3.6.1.4.1.2.6.159.1.1.200.2.1.11ColumnibmSystemRaidControllerInitiatorIDsread-onlymandatorySpecifies the controllers initiator IDs using a comma as the delimiter
1.3.6.1.4.1.2.6.159.1.1.200.2.1.12ColumnibmSystemRaidControllerStatusread-onlymandatoryThe current status of the controller
1.3.6.1.4.1.2.6.159.1.1.200.3TableibmSystemRaidDiskDriveTablenot-accessiblemandatoryThe IBMPSG_RAIDDiskDrive class represents a RAID physical disk
1.3.6.1.4.1.2.6.159.1.1.200.3.1RowibmSystemRaidDiskDriveEntrynot-accessiblemandatoryThis class defines an entry for each IBMPSG_RAIDDiskDrive instance. Each instance of the IBMPSG_RAIDDiskDrive class contains status and descriptive information…
1.3.6.1.4.1.2.6.159.1.1.200.3.1.1ColumnibmSystemRaidDiskDriveKeyIndexread-onlymandatoryThe Physical Disk Drive table index number (Disk Drive 0, Disk Drive 1, etc.)
1.3.6.1.4.1.2.6.159.1.1.200.3.1.2ColumnibmSystemRaidDiskDriveDeviceIDread-onlymandatoryThe device ID of the drive
1.3.6.1.4.1.2.6.159.1.1.200.3.1.3ColumnibmSystemRaidDiskDriveDiskDriveIDread-onlymandatoryThe target ID of the disk drive
1.3.6.1.4.1.2.6.159.1.1.200.3.1.4ColumnibmSystemRaidDiskDriveControllerIDread-onlymandatoryThe ID of the controller it is attached to
1.3.6.1.4.1.2.6.159.1.1.200.3.1.5ColumnibmSystemRaidDiskDriveChannelIDread-onlymandatoryThe channel on the controller the drive is attached to
1.3.6.1.4.1.2.6.159.1.1.200.3.1.6ColumnibmSystemRaidDiskDriveFirmwareread-onlymandatoryThe firmware revision of the drive
1.3.6.1.4.1.2.6.159.1.1.200.3.1.7ColumnibmSystemRaidDiskDriveStateread-onlymandatoryThe current state of the physical drive. 0=Empty, 1=Standby, 4=Defunct Hot Spare, 5=Standby Hot Spare, 8=Defunct Disk Drive, 129=Ready, 133=Hot Spare, 137=Onli…
1.3.6.1.4.1.2.6.159.1.1.200.3.1.8ColumnibmSystemRaidDiskDriveStatusread-onlymandatoryThe status of the drive
1.3.6.1.4.1.2.6.159.1.1.200.4TableibmSystemRaidLogicalDriveTablenot-accessiblemandatoryThe IBMPSG_RAIDLogicalDrive class represents a RAID Logical disk (Logical Drive 0, Logical Drive 1, etc.)
1.3.6.1.4.1.2.6.159.1.1.200.4.1RowibmSystemRaidLogicalDriveEntrynot-accessiblemandatoryThis class defines an entry for each IBMPSG_RAIDLogicalDrive instance. Each instance of the IBMPSG_RAIDLogicalDrive class contains status and descriptive infor…
1.3.6.1.4.1.2.6.159.1.1.200.4.1.1ColumnibmSystemRaidLogicalDriveKeyIndexread-onlymandatoryThe Logical Disk Drive table index number (Logical Drive 0, Logical Drive 1, etc.)
1.3.6.1.4.1.2.6.159.1.1.200.4.1.2ColumnibmSystemRaidLogicalDriveLogicalDriveIDread-onlymandatoryThe ID of the logical drive
1.3.6.1.4.1.2.6.159.1.1.200.4.1.3ColumnibmSystemRaidLogicalDriveControllerIDread-onlymandatoryThe ID of the controller the logical drive belongs to
1.3.6.1.4.1.2.6.159.1.1.200.4.1.4ColumnibmSystemRaidLogicalDriveArrayIDread-onlymandatoryThe ID of the array that the logical drive belongs to
1.3.6.1.4.1.2.6.159.1.1.200.4.1.5ColumnibmSystemRaidLogicalDriveRAIDLevelread-onlymandatoryThe RAID level of the logical drive (RAID 1, RAID 5, etc.)
1.3.6.1.4.1.2.6.159.1.1.200.4.1.6ColumnibmSystemRaidLogicalDriveDataSpaceread-onlymandatorySize of the logical drive in megabytes
1.3.6.1.4.1.2.6.159.1.1.200.4.1.7ColumnibmSystemRaidLogicalDriveParitySpaceread-onlymandatoryParity space of the logical drive in megabytes
1.3.6.1.4.1.2.6.159.1.1.200.4.1.8ColumnibmSystemRaidLogicalDriveIsBlockedread-onlymandatoryThe logical drive is in a blocked state
1.3.6.1.4.1.2.6.159.1.1.200.4.1.9ColumnibmSystemRaidLogicalDriveStateread-onlymandatoryThe current state of the logical drive. 0=Free, 2=Offline, 3=Okay, 4=Critical, 5=Logical Drive Migration, 6=System, 20=Critical Logical Drive Migration, 36=Cri…
1.3.6.1.4.1.2.6.159.1.1.200.4.1.10ColumnibmSystemRaidLogicalDriveStatusread-onlymandatoryThe status of the logical drive
1.3.6.1.4.1.2.6.159.1.1.200.5NodeibmSystemRaidTrapInfo
1.3.6.1.4.1.2.6.159.1.1.200.5.1ScalaribmSystemRaidTrapProviderNamenot-accessiblemandatoryThe CIM Provider Name
1.3.6.1.4.1.2.6.159.1.1.200.5.2ScalaribmSystemRaidTrapEventIDnot-accessiblemandatoryEvent ID
1.3.6.1.4.1.2.6.159.1.1.200.5.3ScalaribmSystemRaidTrapPerceivedSeveritynot-accessiblemandatorySeverity of the event 0=Normal / OK 1=Warning 2=Critical
1.3.6.1.4.1.2.6.159.1.1.200.5.4ScalaribmSystemRaidDescriptionnot-accessiblemandatoryThe event message
1.3.6.1.4.1.2.6.159.1.1.200.5.5ScalaribmSystemRaidTrapEventTimenot-accessiblemandatoryTime that the event occured