MIB Viewer

IEEE8021-AS-MIB

137 objects
The Management Information Base module for IEEE 802.1AS time synchronization protocol.
OIDNameAccessStatusDescription
1.3.111.2.802.1.1.20Identityieee8021AsTimeSyncMibThe Management Information Base module for IEEE 802.1AS time synchronization protocol.
1.3.111.2.802.1.1.20.1Nodeieee8021AsMIBObjects
1.3.111.2.802.1.1.20.1.1Nodeieee8021AsDefaultDS
1.3.111.2.802.1.1.20.1.1.1Scalarieee8021AsDefaultDSClockIdentityread-onlycurrentGlobally unique manufacturer-assigned clock identifier for the local clock. The identifier is based on an EUI-64.
1.3.111.2.802.1.1.20.1.1.2Scalarieee8021AsDefaultDSNumberPortsread-onlycurrentThe number of PTP ports on the device. For an end station the value is 1.
1.3.111.2.802.1.1.20.1.1.3Scalarieee8021AsDefaultDSClockClassread-onlycurrentDenotes the traceability of the time or frequency of the local clock. The value shall be selected as follows: a) If the Default Parameter Data Set member gmCap…
1.3.111.2.802.1.1.20.1.1.4Scalarieee8021AsDefaultDSClockAccuracyread-onlycurrentCharacterizes local clock for the purpose of the best master clock algorithm. The value shall be selected as follows: a) clockAccuracy is set to the value that…
1.3.111.2.802.1.1.20.1.1.5Scalarieee8021AsDefaultDSOffsetScaledLogVarianceread-onlycurrentThe offsetScaledLogVariance is scaled, offset representation of an estimate of the PTP variance. The PTP variance characterizes the precision and frequency sta…
1.3.111.2.802.1.1.20.1.1.6Scalarieee8021AsDefaultDSPriority1read-writecurrentMost-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The value of priority1 shall be 255 fo…
1.3.111.2.802.1.1.20.1.1.7Scalarieee8021AsDefaultDSPriority2read-writecurrentLeast-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The default value is 248
1.3.111.2.802.1.1.20.1.1.8Scalarieee8021AsDefaultDSGmCapableread-onlycurrentTrue (1) if master clock capable; false (2) otherwise.
1.3.111.2.802.1.1.20.1.1.9Scalarieee8021AsDefaultDSCurrentUTCOffsetread-onlycurrentThe value is the offset between TAI and UTC, relative to the ClockMaster entity of this time-aware system. It is equal to the global variable sysCurrentUtcOffs…
1.3.111.2.802.1.1.20.1.1.10Scalarieee8021AsDefaultDSCurrentUTCOffsetValidread-onlycurrentTrue (1) if ieee8021AsDefaultDSCurrentUTCOffset is known to be correct; false (2) otherwise.
1.3.111.2.802.1.1.20.1.1.11Scalarieee8021AsDefaultDSLeap59read-onlycurrentA true (1) value indicates that the last minute of the current UTC day, relative to the ClockMaster entity of this time-aware system, will contain 59 seconds. …
1.3.111.2.802.1.1.20.1.1.12Scalarieee8021AsDefaultDSLeap61read-onlycurrentA true (1) value indicates that the last minute of the current UTC day, relative to the ClockMaster entity of this time-aware system, will contain 59 seconds. …
1.3.111.2.802.1.1.20.1.1.13Scalarieee8021AsDefaultDSTimeTraceableread-onlycurrentThe value is set to true (1) if the timescale and the value of Ieee8021AsCurrentUtcOffset, relative to the ClockMaster entity of this time-aware system, are tr…
1.3.111.2.802.1.1.20.1.1.14Scalarieee8021AsDefaultDSFrequencyTraceableread-onlycurrentThe value is set to true (1) if the frequency determining the timescale of the ClockMaster Entity of this time- aware system is traceable to a primary referenc…
1.3.111.2.802.1.1.20.1.1.15Scalarieee8021AsDefaultDSTimeSourceread-onlycurrentThe timeSource is an information-only attribute indicating the type of source of time used by a ClockMaster. The value is not used in the selection of the gran…
1.3.111.2.802.1.1.20.1.2Nodeieee8021AsCurrentDS
1.3.111.2.802.1.1.20.1.2.1Scalarieee8021AsCurrentDSStepsRemovedread-onlycurrentThe number of communication paths traversed between the local clock and the grandmaster clock (see Table 10.3.3). For example, stepsRemoved for a slave clock o…
1.3.111.2.802.1.1.20.1.2.2Scalarieee8021AsCurrentDSOffsetFromMasterHsread-onlycurrentThe most significant 32 bits of the offset, signed 96 bit number in 2**-16 ns, an implementation-specific computation of the current value of the time differen…
1.3.111.2.802.1.1.20.1.2.3Scalarieee8021AsCurrentDSOffsetFromMasterMsread-onlycurrentThe middle significant 32 bits of the offset, signed 96 bit number in 2**-16 ns, an implementation-specific computation of the current value of the time differ…
1.3.111.2.802.1.1.20.1.2.4Scalarieee8021AsCurrentDSOffsetFromMasterLsread-onlycurrentThe least significant 32 bits of the offset, signed 96 bit number in 2**-16 ns, an implementation-specific computation of the current value of the time differe…
1.3.111.2.802.1.1.20.1.2.5Scalarieee8021AsCurrentDSLastGmPhaseChangeHsread-onlycurrentThe value (see 10.2.3.16) is the phase change that occurred on the most recent change in either grandmaster or gmTimeBaseIndicator (see 9.2.2.2). This object M…
1.3.111.2.802.1.1.20.1.2.6Scalarieee8021AsCurrentDSLastGmPhaseChangeMsread-onlycurrentThe value (see 10.2.3.16) is the phase change that occurred on the most recent change in either grandmaster or gmTimeBaseIndicator (see 9.2.2.2). This object M…
1.3.111.2.802.1.1.20.1.2.7Scalarieee8021AsCurrentDSLastGmPhaseChangeLsread-onlycurrentThe value (see 10.2.3.16) is the phase change that occurred on the most recent change in either grandmaster or gmTimeBaseIndicator (see 9.2.2.2). This object M…
1.3.111.2.802.1.1.20.1.2.8Scalarieee8021AsCurrentDSLastGmFreqChangeMsread-onlycurrentThe value (see 10.2.3.17) is the frequency change that occurred on the most recent change in either grandmaster or gmTimeBaseIndicator (see 9.2.2.2). This obje…
1.3.111.2.802.1.1.20.1.2.9Scalarieee8021AsCurrentDSLastGmFreqChangeLsread-onlycurrentThe value (see 10.2.3.17) is the frequency change that occurred on the most recent change in either grandmaster or gmTimeBaseIndicator (see 9.2.2.2). This obje…
1.3.111.2.802.1.1.20.1.2.10Scalarieee8021AsCurrentDSGmTimebaseIndicatorread-onlycurrentThis reports the grandmaster's time base change value conveyed in the Sync message. The value is the value of timeBaseIndicator of the current grandmaster (see…
1.3.111.2.802.1.1.20.1.2.11Scalarieee8021AsCurrentDSGmChangeCountread-onlycurrentThis statistics counter tracks the number of times the grandmaster has changed in a gPTP domain. This counter increments when the PortAnnounceInformation state…
1.3.111.2.802.1.1.20.1.2.12Scalarieee8021AsCurrentDSTimeOfLastGmChangeEventread-onlycurrentThis timestamp denotes the system time when the most recent grandmaster change occurred in a gPTP domain. This timestamp is updated when the PortAnnounceInform…
1.3.111.2.802.1.1.20.1.2.13Scalarieee8021AsCurrentDSTimeOfLastGmFreqChangeEventread-onlycurrentThis timestamp denotes the system time when the most recent change in grandmaster phase occured, due to a change of either the grandmaster or the grandmaster t…
1.3.111.2.802.1.1.20.1.2.14Scalarieee8021AsCurrentDSTimeOfLastGmPhaseChangeEventread-onlycurrentThis timestamp denotes the system time when the most recent change in grandmaster frequency occured, due to a change of either the grandmaster or the grandmast…
1.3.111.2.802.1.1.20.1.3Nodeieee8021AsParentDS
1.3.111.2.802.1.1.20.1.3.1Scalarieee8021AsParentDSParentClockIdentityread-onlycurrentClock identifier (clockIdentity) of the local clock's parent clock. The default value is set to ieee8021AsDefaultDSClockIdentity. If this time-aware system is …
1.3.111.2.802.1.1.20.1.3.2Scalarieee8021AsParentDSParentPortNumberread-onlycurrentPort number (portNumber) of the local clock's parent gPTP port number. If this time-aware system is the grandmaster, the value is the gPTP portNumber of this t…
1.3.111.2.802.1.1.20.1.3.3Scalarieee8021AsParentDSCumlativeRateRatioread-onlycurrentThe value is an estimate of the ratio of the frequency of the grandmaster to the frequency of the LocalClock entity of this time-aware system. Cumulative rate …
1.3.111.2.802.1.1.20.1.3.4Scalarieee8021AsParentDSGrandmasterIdentityread-onlycurrentClock identifier (clockIdentity) of the grandmaster. The default value is set to ieee8021AsDefaultDSClockIdentity.
1.3.111.2.802.1.1.20.1.3.5Scalarieee8021AsParentDSGrandmasterClockClassread-onlycurrentDenotes the traceability of the time or frequency of the grandmaster. The default value is set to ieee8021AsDefaultDSClockClass.
1.3.111.2.802.1.1.20.1.3.6Scalarieee8021AsParentDSGrandmasterClockAccuracyread-onlycurrentCharacterizes the grandmaster clock for the purpose of the best master clock algorithm. The default value is set to ieee8021AsDefaultDSClockAccuracy.
1.3.111.2.802.1.1.20.1.3.7Scalarieee8021AsParentDSGrandmasterOffsetScaledLogVarianceread-onlycurrentClock Allan variance of the local clock expressed as a base-2 logarithm multiplied by a scale factor of 256. Hysteresis is applied requiring the underlying com…
1.3.111.2.802.1.1.20.1.3.8Scalarieee8021AsParentDSGrandmasterPriority1read-writecurrentGrandmaster's most-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The default value is set…
1.3.111.2.802.1.1.20.1.3.9Scalarieee8021AsParentDSGrandmasterPriority2read-writecurrentGrandmaster's least-significant priority declaration in the execution of the best master clock algorithm. Lower values take precedence. The default value is se…
1.3.111.2.802.1.1.20.1.4Nodeieee8021AsTimePropertiesDS
1.3.111.2.802.1.1.20.1.4.1Scalarieee8021AsTimePropertiesDSCurrentUtcOffsetread-onlycurrentThe value is currentUtcOffset for the current grandmaster (see Table 14.2.9). It is equal to the value of the global variable currentUtcOffset (see 10.3.8.9). …
1.3.111.2.802.1.1.20.1.4.2Scalarieee8021AsTimePropertiesDSCurrentUtcOffsetValidread-onlycurrentTrue (1) if ieee8021AsTimePropertiesDSCurrentUTCOffset is known to be correct; false (2) otherwise. The default value is set to ieee8021AsDefaultDSCurrentUTCOf…
1.3.111.2.802.1.1.20.1.4.3Scalarieee8021AsTimePropertiesDSLeap59read-onlycurrentThe value is leap59 for the current grandmaster (see 14.2.11). It is equal to the global variable leap59 (see 10.3.8.5). A true (1) value indicates that the la…
1.3.111.2.802.1.1.20.1.4.4Scalarieee8021AsTimePropertiesDSLeap61read-onlycurrentThe value is leap61 for the current grandmaster (see 14.2.12). It is equal to the global variable leap59 (see 10.3.8.4). A true (1) value indicates that the la…
1.3.111.2.802.1.1.20.1.4.5Scalarieee8021AsTimePropertiesDSTimeTraceableread-onlycurrentThe value is timeTraceable for the current grandmaster (see 14.2.13). It is equal to the global variable timeTraceable (see 10.3.8.7). True (1) if the timescal…
1.3.111.2.802.1.1.20.1.4.6Scalarieee8021AsTimePropertiesDSFrequencyTraceableread-onlycurrentThe value is frequencyTraceable for the current grandmaster (see 14.2.14). It is equal to the global variable frequencyTraceable (see 10.3.8.8). True (1) if th…
1.3.111.2.802.1.1.20.1.4.7Scalarieee8021AsTimePropertiesDSTimeSourceread-onlycurrentThe value is timeSource for the current grandmaster (see 14.2.15). It is equal to the global variable timeTraceable (see 10.3.8.10). Indicates the source of ti…
1.3.111.2.802.1.1.20.1.5Tableieee8021AsPortDSIfTablenot-accessiblecurrentA table of gPTP port related variables in a time-aware Bridge or for a time-aware end station. A value of 1 is used in a bridge or an end station that does not…
1.3.111.2.802.1.1.20.1.5.1Rowieee8021AsPortDSIfEntrynot-accessiblecurrentA list of objects pertaining to a gPTP port of a time-aware bridge component or a time-aware end station.
1.3.111.2.802.1.1.20.1.5.1.1Columnieee8021AsBridgeBasePortnot-accessiblecurrentThis object identifies the bridge port number of the port for which this entry contains bridge management information. For end stations, this port number shall…
1.3.111.2.802.1.1.20.1.5.1.2Columnieee8021AsPortDSAsIfIndexnot-accessiblecurrentThis object identifies the gPTP interface group within the system for which this entry contains information. It is the value of the instance of the IfIndex obj…
1.3.111.2.802.1.1.20.1.5.1.3Columnieee8021AsPortDSClockIdentityread-onlycurrentThe clockIdentity is an 8 octet array formed by mapping an IEEE EUI-48 assigned to the time-aware system to IEEE EUI-64 format (i.e., to an array of 8 octets).…
1.3.111.2.802.1.1.20.1.5.1.4Columnieee8021AsPortDSPortNumberread-onlycurrentThe portNumber value for a port on a time-aware end station (i.e., a time-aware system supporting a single gPTP port) shall be 1. The portNumber values for the…
1.3.111.2.802.1.1.20.1.5.1.5Columnieee8021AsPortDSPortRoleread-onlycurrentThe value is the value of the port role of this port (see Table 10-1), and is taken from the enumeration in Table 14-5. All other values reserved. The enumerat…
1.3.111.2.802.1.1.20.1.5.1.6Columnieee8021AsPortDSPttPortEnabledread-writecurrent802.1AS function enable for a given port. True (1) if the time-synchronization and best master selection functions of the port are enabled; False (2) otherwise…
1.3.111.2.802.1.1.20.1.5.1.7Columnieee8021AsPortDSIsMeasuringDelayread-onlycurrentTrue (1) if the port is measuring link propagation delay; The value is equal to the value of the Boolean isMeasuringPdDelay (see 11.2.12.5 and E.4.3.2) False (…
1.3.111.2.802.1.1.20.1.5.1.8Columnieee8021AsPortDSAsCapableread-onlycurrentTrue (1) if and only if it is determined that this time-aware system and the time-aware system at the other ends of the link attached to this port can interope…
1.3.111.2.802.1.1.20.1.5.1.9Columnieee8021AsPortDSNeighborPropDelayHsread-onlycurrentThe most (highest) significant 32 bits, unsigned 96 bit number in 2**-16 ns, the value is equal to the value of the per-port global variable neighborPropDelay …
1.3.111.2.802.1.1.20.1.5.1.10Columnieee8021AsPortDSNeighborPropDelayMsread-onlycurrentThe second most (middle) significant 32 bits, unsigned 96 bit number in 2**-16 ns, the value is equal to the value of the per-port global variable neighborProp…
1.3.111.2.802.1.1.20.1.5.1.11Columnieee8021AsPortDSNeighborPropDelayLsread-onlycurrentThe least significant 32 bits, unsigned 96 bit number in 2**-16 ns, the value is equal to the value of the per-port global variable neighborPropDelay (see 10.2…
1.3.111.2.802.1.1.20.1.5.1.12Columnieee8021AsPortDSNeighborPropDelayThreshHsread-writecurrentThe most (highest) significant 32 bits, unsigned 96 bit number in 2**-16 ns, the value is equal to the value of the per-port global variable neighborPropDelayT…
1.3.111.2.802.1.1.20.1.5.1.13Columnieee8021AsPortDSNeighborPropDelayThreshMsread-writecurrentThe middle significant 32 bits, unsigned 96 bit number in 2**-16 ns, the value is equal to the value of the per-port global variable neighborPropDelayThresh (s…
1.3.111.2.802.1.1.20.1.5.1.14Columnieee8021AsPortDSNeighborPropDelayThreshLsread-writecurrentThe least significant 32 bits, unsigned 96 bit number in 2**-16 ns, the value is equal to the value of the per-port global variable neighborPropDelayThresh (se…
1.3.111.2.802.1.1.20.1.5.1.15Columnieee8021AsPortDSDelayAsymmetryHsread-writecurrentThe most (highest) significant 32 bits, signed 96 bit number in 2**-16 ns. The value is the asymmetry in the propagation delay on the link attached to this por…
1.3.111.2.802.1.1.20.1.5.1.16Columnieee8021AsPortDSDelayAsymmetryMsread-writecurrentThe middle significant 32 bits, signed 96 bit number in 2**-16 ns. The value is the asymmetry in the propagation delay on the link attached to this port relati…
1.3.111.2.802.1.1.20.1.5.1.17Columnieee8021AsPortDSDelayAsymmetryLsread-writecurrentThe least significant 32 bits, signed 96 bit number in 2**-16 ns. The value is the asymmetry in the propagation delay on the link attached to this port relativ…
1.3.111.2.802.1.1.20.1.5.1.18Columnieee8021AsPortDSNeighborRateRatioread-onlycurrentThe value is an estimate of the ratio of the frequency of the LocalClock entity of the time-aware system at the other end of the link attached to this port, to…
1.3.111.2.802.1.1.20.1.5.1.19Columnieee8021AsPortDSInitialLogAnnounceIntervalread-writecurrentThe value is the logarithm to the base 2 of the of the announce interval used when (a) the port is initialized, or (b) a message interval request TLV is receiv…
1.3.111.2.802.1.1.20.1.5.1.20Columnieee8021AsPortDSCurrentLogAnnounceIntervalread-onlycurrentThe value is the logarithm to the base 2 of the of the current announce transmission interval. The currentLogAnnounceInterval specifies the current value of th…
1.3.111.2.802.1.1.20.1.5.1.21Columnieee8021AsPortDSAnnounceReceiptTimeoutread-writecurrentThe value is the number of Announce message transmission intervals that a slave port waits without receiving an Announce message, before assuming that the mast…
1.3.111.2.802.1.1.20.1.5.1.22Columnieee8021AsPortDSInitialLogSyncIntervalread-writecurrentThe value is the logarithm to the base 2 of the sync interval used when, (a) the port is initialized, or (b) a message interval request TLV is received with th…
1.3.111.2.802.1.1.20.1.5.1.23Columnieee8021AsPortDSCurrentLogSyncIntervalread-onlycurrentThe value is the logarithm to the base 2 of the current time-synchronization transmission interval, see 10.6.2.3. The initialization value is -3.
1.3.111.2.802.1.1.20.1.5.1.24Columnieee8021AsPortDSSyncReceiptTimeoutread-writecurrentThe value of this attribute tells a slave port the number of sync intervals to wait without receiving synchronization information, before assuming that the mas…
1.3.111.2.802.1.1.20.1.5.1.25Columnieee8021AsPortDSSyncReceiptTimeoutTimeIntervalHsread-onlycurrentThe most (highest) significant 32 bits, of unsigned 96 bit number in 2**-16 ns. The value is equal to the value of the per port global variable syncReceiptTime…
1.3.111.2.802.1.1.20.1.5.1.26Columnieee8021AsPortDSSyncReceiptTimeoutTimeIntervalMsread-onlycurrentThe middle significant 32 bits, unsigned 96 bit number in 2**-16 ns. The value is equal to the value of the per port global variable syncReceiptTimeoutTimeInte…
1.3.111.2.802.1.1.20.1.5.1.27Columnieee8021AsPortDSSyncReceiptTimeoutTimeIntervalLsread-onlycurrentThe least significant 32 bits, unsigned 96 bit number in 2**-16 ns. The value is equal to the value of the per port global variable syncReceiptTimeoutTimeInter…
1.3.111.2.802.1.1.20.1.5.1.28Columnieee8021AsPortDSInitialLogPdelayReqIntervalread-writecurrentFor full-duplex, IEEE 802.3 media and CSN media that use the peer delay mechanism to measure path delay (see E.4.3.1), the value is the logarithm to the base 2…
1.3.111.2.802.1.1.20.1.5.1.29Columnieee8021AsPortDSCurrentLogPdelayReqIntervalread-onlycurrentFor full-duplex, IEEE 802.3 media and CSN media that use the peer delay mechanism to measure path delay (see E.4.3.1), the value is the logarithm to the base 2…
1.3.111.2.802.1.1.20.1.5.1.30Columnieee8021AsPortDSAllowedLostResponsesread-writecurrentThe value is equal to the value of the per-port global variable allowedLostResponses (see 11.2.12.4). It is the number of Pdelay_Req messages for which a valid…
1.3.111.2.802.1.1.20.1.5.1.31Columnieee8021AsPortDSVersionNumberread-onlycurrentIndicates the PTP version in use on the port. The version number for this standard is set to the value 2 (see 10.5.2.2.3). The contents of this variable SHALL …
1.3.111.2.802.1.1.20.1.5.1.32Columnieee8021AsPortDSNupMsread-writecurrentThe most significant 32 bits, of unsigned 64 bit fixed point number between 0 and less than 2. For an OLT port of an IEEE 802.3 EPON link, the value is the eff…
1.3.111.2.802.1.1.20.1.5.1.33Columnieee8021AsPortDSNupLsread-writecurrentThe least significant 32 bits, of unsigned 64 bit fixed point number between 0 and less than 2. For an OLT port of an IEEE 802.3 EPON link, the value is the ef…
1.3.111.2.802.1.1.20.1.5.1.34Columnieee8021AsPortDSNdownMsread-writecurrentThe least significant 32 bits, of unsigned 64 bit fixed point number between 0 and less than 2. For an OLT port of an IEEE 802.3 EPON link, the value is the ef…
1.3.111.2.802.1.1.20.1.5.1.35Columnieee8021AsPortDSNdownLsread-writecurrentThe least significant 32 bits, of unsigned 64 bit fixed point number between 0 and less than 2. For an OLT port of an IEEE 802.3 EPON link, the value is the ef…
1.3.111.2.802.1.1.20.1.5.1.36Columnieee8021AsPortDSAcceptableMasterTableEnabledread-writecurrentTrue (1) if acceptableMasterTableEnabled (see 13.1.3.1) and 13.1.3.5) is true and an ONU port attached to an IEEE 802.3 EPON link in a time-aware system. False…
1.3.111.2.802.1.1.20.1.6Tableieee8021AsPortStatIfTablenot-accessiblecurrentA table of time-aware port related counters in a gPTP domain. A value of 1 is used in a bridge or an end station that does not have multiple components.
1.3.111.2.802.1.1.20.1.6.1Rowieee8021AsPortStatIfEntrynot-accessiblecurrentA list of statistics pertaining to a port of a gPTP domain. This statistics table uses ieee8021AsPortDSAsIfIndex, and corresponds to ieee8021ASPortDSTable entr…
1.3.111.2.802.1.1.20.1.6.1.1Columnieee8021AsPortStatRxSyncCountread-onlycurrentA counter that increments every time synchronization information is received, denoted by a transition to TRUE from FALSE of the rcvdSync variable of the MDSync…
1.3.111.2.802.1.1.20.1.6.1.2Columnieee8021AsPortStatRxFollowUpCountread-onlycurrentA counter that increments every time a Follow_Up message is received, denoted by a transition to TRUE from FALSE of the rcvdFollowUp variable of the MDSyncRece…
1.3.111.2.802.1.1.20.1.6.1.3Columnieee8021AsPortStatRxPdelayRequestread-onlycurrentA counter that increments every time a Pdelay_Req message is received, denoted by a transition to TRUE from FALSE of the rcvdPdelayReq variable of the MDPdelay…
1.3.111.2.802.1.1.20.1.6.1.4Columnieee8021AsPortStatRxPdelayResponseread-onlycurrentA counter that increments every time a Pdelay_Resp message is received, denoted by a transition to TRUE from FALSE of the rcvdPdelayResp variable of the MDPdel…
1.3.111.2.802.1.1.20.1.6.1.5Columnieee8021AsPortStatRxPdelayResponseFollowUpread-onlycurrentA counter that increments every time a Pdelay_Resp_Follow_Up message is received, denoted by a transition to TRUE from FALSE of the rcvdPdelayRespFollowUp vari…
1.3.111.2.802.1.1.20.1.6.1.6Columnieee8021AsPortStatRxAnnounceread-onlycurrentA counter that increments every time an Announce message is received, denoted by a transition to TRUE from FALSE of the rcvdAnnounce variable of the PortAnnoun…
1.3.111.2.802.1.1.20.1.6.1.7Columnieee8021AsPortStatRxPTPPacketDiscardread-onlycurrentA counter that increments every time a PTP message is discarded, caused by the occurrence of any of the following conditions: a) A received Announce message is…
1.3.111.2.802.1.1.20.1.6.1.8Columnieee8021AsPortStatRxSyncReceiptTimeoutsread-onlycurrentA counter that increments every time sync receipt timeout occurs, denoted by entering the AGED state of the PortAnnounceInformation state machine (see 10.3.11 …
1.3.111.2.802.1.1.20.1.6.1.9Columnieee8021AsPortStatAnnounceReceiptTimeoutsread-onlycurrentA counter that increments every time announce receipt timeout occurs, denoted by entering the AGED state of the PortAnnounceInformation state machine (see 10.3…
1.3.111.2.802.1.1.20.1.6.1.10Columnieee8021AsPortStatPdelayAllowedLostResponsesExceededread-onlycurrentA counter that increments everytime the value of the variable lostResponses (see, 11.2.15.1.10) exceeds the value of the variable allowedLostResponses (see 11.…
1.3.111.2.802.1.1.20.1.6.1.11Columnieee8021AsPortStatTxSyncCountread-onlycurrentA counter that increments every time synchronization information is transmitted, denoted by a transition to TRUE from FALSE of the rcvdMDSync variable of the M…
1.3.111.2.802.1.1.20.1.6.1.12Columnieee8021AsPortStatTxFollowUpCountread-onlycurrentA counter that increments every time a Follow_Up message is transmitted, denoted by a transition to TRUE from FALSE of the rcvdMDTimestampReceive variable of t…
1.3.111.2.802.1.1.20.1.6.1.13Columnieee8021AsPortStatTxPdelayRequestread-onlycurrentA counter that increments every time a Pdelay_Req message is transmitted, denoted by entering the INITIAL_SEND_PDELAY_REQ or SEND_PDELAY_REQ states of the MDPd…
1.3.111.2.802.1.1.20.1.6.1.14Columnieee8021AsPortStatTxPdelayResponseread-onlycurrentA counter that increments every time a Pdelay_Resp message is transmitted, denoted by a transition to TRUE from FALSE of the rcvdPdelayReq variable of the MDPd…
1.3.111.2.802.1.1.20.1.6.1.15Columnieee8021AsPortStatTxPdelayResponseFollowUpread-onlycurrentA counter that increments every time a Pdelay_Resp_Follow_Up message is transmitted, denoted by a transition to TRUE from FALSE of the rcvdMDTimestampReceive v…
1.3.111.2.802.1.1.20.1.6.1.16Columnieee8021AsPortStatTxAnnounceread-onlycurrentA counter that increments every time an Announce message is transmitted, denoted by entering the TRANSMIT_ANNOUNCE state of the PortAnnounceReceive state machi…
1.3.111.2.802.1.1.20.1.7Nodeieee8021AsAcceptableMasterTableDS
1.3.111.2.802.1.1.20.1.7.1Nodeieee8021AsAcceptableMasterTableDSBase
1.3.111.2.802.1.1.20.1.7.1.1Scalarieee8021AsAcceptableMasterTableDSMaxTableSizeread-onlycurrentThe value is the maximum size of the AcceptableMasterTable. It is equal to the maxTableSize member of the AcceptableMasterTable structure (see 13.1.3.2)
1.3.111.2.802.1.1.20.1.7.1.2Scalarieee8021AsAcceptableMasterTableDSActualTableSizeread-writecurrentThe value is the actual size of the AcceptableMasterTable. It is equal to the actualTableSize member of the AcceptableMasterTable structure (see 13.1.3.2 and 1…
1.3.111.2.802.1.1.20.1.7.2Nodeieee8021AsAcceptableMasterTableDSMaster
1.3.111.2.802.1.1.20.1.7.2.1Tableieee8021AsAcceptableMasterTableDSMasterTablenot-accessiblecurrentA table of time-aware port related variables in a time-aware bridge or for a time-aware end station. A value of 1 is used in a bridge or an end station that do…
1.3.111.2.802.1.1.20.1.7.2.1.1Rowieee8021AsAcceptableMasterTableDSMasterEntrynot-accessiblecurrentA list of objects pertaining to a port of a time-aware bridge component or a time-aware end station.
1.3.111.2.802.1.1.20.1.7.2.1.1.1Columnieee8021AsAcceptableMasterTableDSMasterIdnot-accessiblecurrentAcceptable Master row entry index in this ieee8021AsAcceptableMasterTabdDSMaster Entry applies. If the does not contain Media type of EPON, this variable (inde…
1.3.111.2.802.1.1.20.1.7.2.1.1.2Columnieee8021AsAcceptableMasterClockIdentityread-createcurrentGlobally unique manufacturer-assigned clock identifier for the local clock port. The identifier is based on an EUI-64.
1.3.111.2.802.1.1.20.1.7.2.1.1.3Columnieee8021AsAcceptableMasterPortNumberread-createcurrentThis object represents a Port or aggregated port on a bridge component or end-station. This object and ieee8021AsAcceptableMasterClockIdentity together forms A…
1.3.111.2.802.1.1.20.1.7.2.1.1.4Columnieee8021AsAcceptableMasterAlternatePriority1read-createcurrentIf the alternatePriority1 member of the AcceptableMaster array element that corresponds to the sourcePortIdentity of a received Announce message is greater tha…
1.3.111.2.802.1.1.20.1.7.2.1.1.5Columnieee8021AsAcceptableMasterRowStatusread-createcurrentThis object indicates the status of an entry, and is used to create/delete entries.
1.3.111.2.802.1.1.20.2Nodeieee8021AsConformance
1.3.111.2.802.1.1.20.2.1Nodeieee8021AsCompliances
1.3.111.2.802.1.1.20.2.1.1Complianceieee8021AsCompliancedeprecatedThe compliance statement for support of the IEEE8021-AS-MIB module.
1.3.111.2.802.1.1.20.2.1.2Complianceieee8021AsComplianceCor1read-onlycurrentThe compliance statement for support of the IEEE8021-AS-MIB module.
1.3.111.2.802.1.1.20.2.2Nodeieee8021AsGroups
1.3.111.2.802.1.1.20.2.2.1Groupieee8021ASSystemDefaultReqdGroupcurrentObjects in the System Default required global group.
1.3.111.2.802.1.1.20.2.2.2Groupieee8021ASSystemCurrentGroupcurrentObjects in the System Current global group.
1.3.111.2.802.1.1.20.2.2.3Groupieee8021AsSystemClockParentGroupcurrentObjects in the Clock Parent global group.
1.3.111.2.802.1.1.20.2.2.4Groupieee8021AsSystemTimePropertiesGroupcurrentObjects for the Time Properties Global group.
1.3.111.2.802.1.1.20.2.2.5Groupieee8021AsPortDataSetGlobalGroupcurrentObjects for the port dataset global group.
1.3.111.2.802.1.1.20.2.2.6Groupieee8021ASPortStatisticsGlobalGroupcurrentObjects in the Port statistics global group.
1.3.111.2.802.1.1.20.2.2.7Groupieee8021AsAcceptableMasterBaseGroupcurrentObjects for the Acceptable Master group.
1.3.111.2.802.1.1.20.2.2.8Groupieee8021AsAcceptableMasterTableGroupcurrentObjects for the Acceptable Master group.
1.3.111.2.802.1.1.20.2.3Nodeieee8021AsCompliancesCor1
Type Definitions
NameSyntaxStatusDescription
ClockIdentityOCTET STRING (SIZE (8))currentRepresents an IEEE 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, EUI-64. EUI-48 converts to EUI-64 as specified by IEEE. The conversion assigns values 255 and 254 to octets 3 and 4 respect…
IEEE8021ASClockAccuracyValueINTEGER { timeAccurateTo25ns(32), timeAccurateTo100ns(33), timeAccurateTo250ns(34), timeAccurateTo1us(35), timeAccurateTo2dot5us(36), timeAccurateTo10us(37), timeAccurateTo25us(38), timeAccurateTo100us(39), timeAccurateTo250us(40), timeAccurateTo1ms(41), timeAccurateTo2dot5ms(42), timeAccurateTo10ms(43), timeAccurateTo25ms(44), timeAccurateTo100ms(45), timeAccurateTo250ms(46), timeAccurateTo1s(47), timeAccurateTo10s(48), timeAccurateToGT10s(49), timeAccurateToUnknown(254) }currentClock Accuracy Value from 8.6.2.3, with the following interpretation placed on the value: 32: The time is accurate to within 25 ns, 33: The time is accurate to within 100 ns, 34: The time is accurate to within 250 ns, 3…
IEEE8021ASClockClassValueINTEGER { primarySync(6), primarySyncLost(7), applicationSpecificSync(13), applicationSpecficSyncLost(14), primarySyncAlternativeA(52), applicationSpecificAlternativeA(58), primarySyncAlternativeB(187), applicationSpecficAlternativeB(193), defaultClock(248), slaveOnlyClock(255) }currentClock Class Value from IEEE Std 1588-2008 7.6.2.4, with the following interpretation placed on the value: 6: A clock that is synchronized to a primary reference time source, 7: A clock that has previously been designate…
IEEE8021ASTimeSourceValueINTEGER { atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOscillator(160) }currentThe timeSource is an information only attribute indicating the type of source of time used by a ClockMaster, representing categories. For example, the GPS entry would include not only the GPS system of the U.S. Departme…