INFINERA-ENTITY-CHASSIS-MIB

58 objects
This MIB is modeling for CHASSIS equipment table.
OIDNameAccessStatusDescription
1.3.6.1.4.1.21296.2.2.2.1.13IdentitychassisMIBThis MIB is modeling for CHASSIS equipment table.
1.3.6.1.4.1.21296.2.2.2.1.13.1TablechassisTablenot-accessiblecurrentThis table contains all chassis modules that are currently present in a network element.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1RowchassisEntrynot-accessiblecurrentA row in the CHASSIS table. Each row in the table is identified with a unique entPhysicalIndexID.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.1ColumnchassisMoIdread-createcurrentThis is the primary Key of the objects e.g 1, 2, 3...
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.2ColumnchassisProvChassisTyperead-createcurrentThe provisioned chassis. Valid values: OTC, DTC, DTC-A, DTC-B, and MTC-A.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.3ColumnchassisInstalledChassisTyperead-onlycurrentThe installed chassis type.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.4ColumnchassisProvSerialNumberread-createcurrentThe provisioned serial number of the Expansion Chassis. This field is configured for the expansion chassis in a multi-chassis configuration. This attribute can…
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.5ColumnchassisInstalledSerialNumberread-onlycurrentThe actual serial number of the chassis
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.6ColumnchassisRackNameread-createcurrentThe name of the rack in which the chassis is installed.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.7ColumnchassisRUlocationInRackread-createcurrentThe position of the chassis within the rack. The chassis with lower RU location is displayed at the bottom in the node view and the one with higher number is d…
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.8ColumnchassisSwitchCapabilityModeread-createcurrentThe switch capability mode for the chassis. Valid values: ring and mesh.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.9ColumnchassisInletTemperatureread-onlycurrentTemperature (in Centigrade) of the circuit pack at the inlet. The temperature is displayed as -1 if the circuit pack does not have a temperature sensor.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.10ColumnchassisAcoStateread-createcurrentThe chassis alarm cutoff state.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.11ColumnchassisBayLevelSummaryAlarmReportingread-createcurrentFlag that enables reporting of bay-level alarms. Typically, this is enabled for one chassis within a bay and disabled for all other chassis in the same bay. Va…
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.12ColumnchassisConfiguredMaxPowerDrawread-createcurrentThe estimated power drawn by the chassis. This varies depending on the type of the chassis and associated configuration.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.13ColumnchassisCurrentEstimatedPowerDrawread-onlycurrentThe sum of estimated power drawn by all the currently installed and pre-provisioned FRUs in the chassis. This value is not indicative of the actual power drawn.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.14ColumnchassisEqptMaxPowerDrawread-onlycurrentThe estimated power drawn by the chassis. This varies depending on the type of the chassis and associated configuration.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.15ColumnchassisScmMigrationAllowedread-onlycurrentThis objects indicate whether user can chnage the chassisSwitchCapabilityMode. If this is false user will not be able to chnage.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.16ColumnchassisScmMigrationInProgressread-onlycurrentThis objects indicate that switch capability mode change is in progress.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.17ColumnchassisPowerControlread-onlycurrentThis objects enable the auto power saving if pwoer is hitting the limit.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.18ColumnchassiscurrentInstalledPowerDrawread-onlycurrentThe estimated power drawn by the installed equipment in chassis. This varies depending on the type of the chassis and installed equipment.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.19ColumnchassisConfiguredPemRatingread-createcurrentThis attribute tells what is the compatible PEM rating for the chassis , in case of PEM-35 this attribute should be set to 35 and in case of PEM-70 it should b…
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.20ColumnchassisRowStatusread-createcurrentThe row status of this CHASSIS entry. Because rows in this table are indexed by entPhysicalIndex, to create a new row one must choose a value of entPhysicalInd…
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.21ColumnchassisIsNCChassisread-onlycurrentwhether or not this chassis houses the Node Controller XCM.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.22ColumnchassisSwitchingModeread-onlycurrentcurrent configuration of the chassis switch fabric module.
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.23ColumnchassisMaxAvailablePowerread-onlycurrentMaximum available power in the chassis
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.24ColumnchassisActvTimingSourceread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.25ColumnchassisOperatingTemperatureThresholdread-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.26ColumnchassisConfiguredAmbientTempread-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.27ColumnchassisSkewBudgetread-createcurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.28ColumnchassisPduCktBreakerRatingread-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.29ColumnchassisRebootTimeread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.30ColumnchassisCLEIread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.31ColumnchassisHardwareVersionread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.32ColumnchassisManufacturedDateread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.33ColumnchassisPartNumberread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.34ColumnchassisPONread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.35ColumnchassisHolderTyperead-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.36ColumnchassisHolderStateread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.37ColumnchassisAcceptableEquipmentTypeListread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.38ColumnchassisUnreachableFromManagementread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.39ColumnchassisSerialPortCLIAccessread-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.40ColumnchassisAcliSessionAdminStateread-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.41ColumnchassisFruInsertionDateread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.42ColumnchassisPowerSupplyTyperead-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.43ColumnchassisBaffleTyperead-writecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.44ColumnchassisPmHistStatsEnableread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.45ColumnchassisInletTemperatureOffsetread-writecurrentInlet Temperature Offset
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.46ColumnchassisHasPluggableEepromread-onlycurrentFlag to indicate if the device has pluggable Eeprom
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.47ColumnchassisPluggablePromSerialNumberread-onlycurrentPlugged in Eeprom serial number
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.48ColumnchassisOutletTemperatureread-onlycurrentThe outlet temperature of the chassis
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.49ColumnchassisTTLMaxread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.1.1.50ColumnchassisTTLCurrentDaysread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.1.13.3NodechassisConformance
1.3.6.1.4.1.21296.2.2.2.1.13.3.1NodechassisCompliances
1.3.6.1.4.1.21296.2.2.2.1.13.3.1.1CompliancechassisCompliancecurrent
1.3.6.1.4.1.21296.2.2.2.1.13.3.2NodechassisGroups
1.3.6.1.4.1.21296.2.2.2.1.13.3.2.1GroupchassisGroupcurrent