INFINERA-PM-FEEDPTP-MIB

23 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.21296.2.2.2.3.46IdentityfeedPtpPmMIB
1.3.6.1.4.1.21296.2.2.2.3.46.1TablefeedPtpPmRealTablenot-accessiblecurrentA list of FeedPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex.
1.3.6.1.4.1.21296.2.2.2.3.46.1.1RowfeedPtpPmRealEntrynot-accessiblecurrentA feedPtp entry containing real-time performance information pertaining to Infinera feedPtp interfaces. This table is a subclass of IfCommon.
1.3.6.1.4.1.21296.2.2.2.3.46.1.1.1ColumnfeedPtpPmRealInputVoltageread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.1.1.2ColumnfeedPtpPmRealInputCurrentread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.2TablefeedPtpPmTablenot-accessiblecurrentA list of FeedPtpPm entries. Each entry is uniquely identified by the value of ifIndex.
1.3.6.1.4.1.21296.2.2.2.3.46.2.1RowfeedPtpPmEntrynot-accessiblecurrentA FeedPtp entry containing historical performance information pertaining to Infinera . This table is a subclass of IfCommon. Entries will exist in this table o…
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.1ColumnfeedPtpPmTimestampnot-accessiblecurrentEnd Time stamp for this interval. If this time is later than the current time, then the data for this bucket is currently being collected.
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.2ColumnfeedPtpPmSampleDurationnot-accessiblecurrentThe duration of this sample.
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.3ColumnfeedPtpPmValidityread-onlycurrentFlag indicating if data was valid for the entire interval
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.4ColumnfeedPtpPmInputVoltageMinread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.5ColumnfeedPtpPmInputVoltageMaxread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.6ColumnfeedPtpPmInputVoltageAveread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.7ColumnfeedPtpPmInputCurrentMinread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.8ColumnfeedPtpPmInputCurrentMaxread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.2.1.9ColumnfeedPtpPmInputCurrentAveread-onlycurrent
1.3.6.1.4.1.21296.2.2.2.3.46.3NodefeedPtpPmConformance
1.3.6.1.4.1.21296.2.2.2.3.46.3.1NodefeedPtpPmCompliances
1.3.6.1.4.1.21296.2.2.2.3.46.3.1.1CompliancefeedPtpPmCompliancecurrentDescribes the requirements for conformance to the feedPtp-MIB
1.3.6.1.4.1.21296.2.2.2.3.46.3.1.2CompliancefeedPtpPmRealCompliancecurrentDescribes the requirements for conformance to the FeedPtpPmReal-MIB
1.3.6.1.4.1.21296.2.2.2.3.46.3.2NodefeedPtpPmGroups
1.3.6.1.4.1.21296.2.2.2.3.46.3.2.1GroupfeedPtpPmGroupcurrentA collection of objects for reading the historical performance of the feedPtp.
1.3.6.1.4.1.21296.2.2.2.3.46.3.2.2GroupfeedPtpPmRealGroupcurrentA collection of objects for reading the real-time performance of the feedPtp.