INFINERA-PM-FRMSCGPTP-MIB
23 objects
No module-level DESCRIPTION found.
Imported Objects
| IF-MIB | ifIndex |
| INFINERA-REG-MIB | perfMon |
| INFINERA-TC-MIB | FloatHundredths InfnSampleDuration |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21296.2.2.2.3.41 | IdentityfrmScgPtpPmMIB | |||
| 1.3.6.1.4.1.21296.2.2.2.3.41.1 | TablefrmScgPtpPmRealTable | not-accessible | current | A list of FrmScgPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.1.1 | RowfrmScgPtpPmRealEntry | not-accessible | current | A frmScgPtp entry containing real-time performance information pertaining to Infinera frmScgPtp interfaces. This table is a subclass of IfCommon. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.1.1.1 | ColumnfrmScgPtpPmRealCmnScgOpt | read-only | current | Total FrmScg optical power trasmit. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.1.1.2 | ColumnfrmScgPtpPmRealCmnScgOpr | read-only | current | Total FrmScg optical power receive. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2 | TablefrmScgPtpPmTable | not-accessible | current | A list of FrmScgPtpPm entries. Each entry is uniquely identified by the value of ifIndex. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1 | RowfrmScgPtpPmEntry | not-accessible | current | A FrmScgPtp entry containing historical performance information pertaining to Infinera OFXSCGPTP. This table is a subclass of IfCommon. Entries will exist in t… |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.1 | ColumnfrmScgPtpPmTimestamp | not-accessible | current | End Time stamp for this interval. If this time is later than the current time,then the data for this bucket is currently being collected. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.2 | ColumnfrmScgPtpPmSampleDuration | not-accessible | current | The duration of this sample. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.3 | ColumnfrmScgPtpPmValidity | read-only | current | Flag indicating if data was valid for the entire interval |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.4 | ColumnfrmScgPtpPmCmnScgOptMin | read-only | current | Minimum FrmScg optical power min. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.5 | ColumnfrmScgPtpPmCmnScgOptMax | read-only | current | Maximum FrmScg optical power max. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.6 | ColumnfrmScgPtpPmCmnScgOptAve | read-only | current | Average FrmScg optical power ave. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.7 | ColumnfrmScgPtpPmCmnScgOprMin | read-only | current | Minimum FrmScg optical power min. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.8 | ColumnfrmScgPtpPmCmnScgOprMax | read-only | current | Maximum FrmScg optical power max. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.2.1.9 | ColumnfrmScgPtpPmCmnScgOprAve | read-only | current | Average FrmScg optical power ave. |
| 1.3.6.1.4.1.21296.2.2.2.3.41.3 | NodefrmScgPtpPmConformance | |||
| 1.3.6.1.4.1.21296.2.2.2.3.41.3.1 | NodefrmScgPtpPmCompliances | |||
| 1.3.6.1.4.1.21296.2.2.2.3.41.3.1.1 | CompliancefrmScgPtpPmCompliance | current | Describes the requirements for conformance to the frmScgPtp-MIB | |
| 1.3.6.1.4.1.21296.2.2.2.3.41.3.1.2 | CompliancefrmScgPtpPmRealCompliance | current | Describes the requirements for conformance to the FrmScgPtpPmReal-MIB | |
| 1.3.6.1.4.1.21296.2.2.2.3.41.3.2 | NodefrmScgPtpPmGroups | |||
| 1.3.6.1.4.1.21296.2.2.2.3.41.3.2.1 | GroupfrmScgPtpPmGroup | current | A collection of objects for reading the historical performance of the frmScgPtp. | |
| 1.3.6.1.4.1.21296.2.2.2.3.41.3.2.2 | GroupfrmScgPtpPmRealGroup | current | A collection of objects for reading the real-time performance of the frmScgPtp. |