INFINERA-TP-BMMOCGPTP-MIB
23 objects
No module-level DESCRIPTION found.
Imported Objects
| IF-MIB | ifIndex |
| INFINERA-REG-MIB | terminationPoint |
| INFINERA-TC-MIB | FloatTenths InfnOcgChannelMap InfnOcgPortConfig InfnPmHistStatsControl InfnPowerControlLoop InfnShutterState InfnSignalType |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21296.2.2.2.2.3 | IdentitybmmOcgPtpMIB | |||
| 1.3.6.1.4.1.21296.2.2.2.2.3.1 | TablebmmOcgPtpTable | not-accessible | current | A list of BmmOcgPtp entries. Each entry is uniquely identified by the value of ifIndex. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1 | RowbmmOcgPtpEntry | not-accessible | current | A BmmOcgPtp entry containing information pertaining to Infinera BMM OCG PTP interfaces. This table is a subclass of IfCommon. Entries will exist in this table … |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.1 | ColumnbmmOcgPtpDiscoveredOcgTP | read-only | current | This refers to the name of the LM/BMM OCG PTP to which this fiber is connected. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.2 | ColumnbmmOcgPtpProvisionedOcgTP | read-write | current | This refers to the name of the LM/BMM OCG PTP to which this fiber is configured. If the configured does not match the discovered, a mismatch alarm shall be rai… |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.3 | ColumnbmmOcgPtpOcgNumber | read-only | current | The OCG number that this BMM OCG TP is associated to. This maps 1-to-1 with the DLM/XLM type. Auto-discovery processes needs to ensure that the ocgNumber and t… |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.4 | ColumnbmmOcgPtpOcgPowerControlLoop | read-write | current | Parameter that indicates whether OCG Control Loop is enabled or disabled. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.5 | ColumnbmmOcgPtpTargetRxOcgPower | read-only | current | The target power per OCG, computed by the BMM. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.6 | ColumnbmmOcgPtpMuxInsertionLoss | read-only | current | The insertion loss from the OCG input to the TX EDFA Input. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.7 | ColumnbmmOcgPtpDeMuxInsertionLoss | read-only | current | The insertion loss from the RX EDFA Output to the OCG Output. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.8 | ColumnbmmOcgPtpPmHistStatsEnable | read-write | current | Flag to enable or disable PM collection. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.9 | ColumnbmmOcgPtpOcgPortConfig | read-only | current | Parameter that indicates whether the BMM OCG is configured as Express or Add/Drop. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.10 | ColumnbmmOcgPtpOcgSignalType | read-write | current | Signal type carried over OCG. |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.11 | ColumnbmmOcgPtpOcgActiveChannelMap | read-write | current | By default, the ocgChannelMap attribute is Zero which implies that the OCG is not carrying alien wavelengths.If the OCG is carrying alien waves (as defined by … |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.12 | ColumnbmmOcgPtpDiscoveredRemoteTP | read-only | current | Discovered Remote TP |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.13 | ColumnbmmOcgPtpAutoDiscSoakTime | read-write | current | |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.14 | ColumnbmmOcgPtpShutterState | read-write | current | |
| 1.3.6.1.4.1.21296.2.2.2.2.3.1.1.15 | ColumnbmmOcgPtpProvOpenWaveRemotePtp | read-write | current | OCG value should be set to Manual in order to provision this attribute |
| 1.3.6.1.4.1.21296.2.2.2.2.3.3 | NodebmmOcgPtpConformance | |||
| 1.3.6.1.4.1.21296.2.2.2.2.3.3.1 | NodebmmOcgPtpCompliances | |||
| 1.3.6.1.4.1.21296.2.2.2.2.3.3.1.1 | CompliancebmmOcgPtpCompliance | current | Describes the requirements for conformance to the BMMOCGPTP-MIB | |
| 1.3.6.1.4.1.21296.2.2.2.2.3.3.2 | NodebmmOcgPtpGroups | |||
| 1.3.6.1.4.1.21296.2.2.2.2.3.3.2.1 | GroupbmmOcgPtpGroup | current | A collection of objects for managing the bmmOcgPtp |