MIB Viewer
MIB Viewer Desktop New

INFINERA-TP-ODUKTCLIENTCTP-MIB

34 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.21296.2.2.2.2.24IdentityoduktClientCtpMIB
1.3.6.1.4.1.21296.2.2.2.2.24.1TableoduktClientCtpTablenot-accessiblecurrentA list of OduktClientCtp entries. Each entry is uniquely identified by the value of ifIndex.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1RowoduktClientCtpEntrynot-accessiblecurrentA OduktClientCtp entry containing information pertaining to Infinera OduktClientCtp interfaces. Entries will exist in this table for interfaces of type oduktcl…
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.1ColumnoduktClientCtpTcmIdentifierread-onlycurrentThe TCM field identifier for this Tandem Connection Monitoring point. This TCM identifier is used along with the Side identifier to explicitly formulate the AI…
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.2ColumnoduktClientCtpSideread-onlycurrentTThe TCM Side identifier for this Tandem Connection Monitoring point. This TCM Side identifier is used along with the TCM identifier to explicitly formulate th…
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.3ColumnoduktClientCtpConfiguredServiceTyperead-onlycurrentThe ODU Service type that is configured on this generic OduClientCtp managed object.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.4ColumnoduktClientCtpAlarmReportControlread-writecurrentThe Alarm Reporting Control Flag for the ODUkT Clients.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.5ColumnoduktClientCtpSupportingCircuitIdListread-onlycurrentThe Supporting Circuit ID List that is this client is using.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.6ColumnoduktClientCtpMonitoringModeread-writecurrentAllowed Section Monitoring / Path Monitoring / TCM Attribute Value(s) (For side corresponding to MonitoringMode) (Fac-Side/Term-Side).
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.7ColumnoduktClientCtpDSThresholdread-writecurrentThis attribute indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of det…
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.8ColumnoduktClientCtpTxTTIread-writecurrentThe TTI message that needs to be transmitted from Trib to Line direction. This message is inserted only when the TribInsertTTI field is set to Enabled.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.9ColumnoduktClientCtpExpectedSAPIread-writecurrentThe Source Access Point Identifier that is expected in the Trib to Line direction.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.10ColumnoduktClientCtpExpectedDAPIread-writecurrentThe Destination Access Point Identifier that is expected in the Trib to Line direction.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.11ColumnoduktClientCtpTimDetModeread-writecurrentThis attribute is used to configure if the TIM-S alarm shall be reported on mismatch of Expected and Received TTI message. The following are the values and the…
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.12ColumnoduktClientCtpReceivedTTIread-onlycurrentThe TTI message received from the side indicated by the AID of the ODUkT CTP.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.13ColumnoduktClientCtpPmHistStatsEnableread-writecurrentFlag to enable or disable the collection of PMs on the side indicated by the AID of the ODUkT CTP.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.14ColumnoduktClientCtpRxEb15MinutesTceread-writecurrentNumber of Error Block in received direction during 15 minutes interval.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.15ColumnoduktClientCtpRxEbDayTceread-writecurrentNumber of Error Block in received direction during 24 hours interval.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.16ColumnoduktClientCtpRxDs15MinutesTceread-writecurrentNumber of Defect Seconds in received direction during 15 minutes interval.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.17ColumnoduktClientCtpRxDsDayTceread-writecurrentNumber of Defect Seconds in receive direction during 24 hours interval.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.18ColumnoduktClientCtpRxEbDayTceReportingread-writecurrentFlag that enables/disables the reporting of RxEbDayTce threshold crossing.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.19ColumnoduktClientCtpRxEb15MinutesTceReportingread-writecurrentFlag that enables/disables the reporting of RxEb15MinutesTce threshold crossing.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.20ColumnoduktClientCtpRxDsDayTceReportingread-writecurrentFlag that enables/disables the reporting of RxDsDayTce threshold crossing.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.21ColumnoduktClientCtpRxDs15MinutesTceReportingread-writecurrentFlag that enables/disables the reporting of RxDs15MinutesTce threshold crossing.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.22ColumnoduktClientCtpSDThresholdread-writecurrentThis attribute indicates the threshold level for declaring a Degraded Signal defect. A Degraded Signal defect shall be declared if SDThreshold consecutive bad …
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.23ColumnoduktClientCtpRxBei15MinutesTceread-writecurrentThis attribute indicates the threshold level for Received BEI counts for 15Min-interval
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.24ColumnoduktClientCtpRxBeiDayTceread-writecurrentThis attribute indicates the threshold level for Received BEI counts for day-interval
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.25ColumnoduktClientCtpRxBei15MinutesTceReportingread-writecurrentFlag that enables/disables the reporting of RxBei15MinutesTce threshold crossing.
1.3.6.1.4.1.21296.2.2.2.2.24.1.1.26ColumnoduktClientCtpRxBeiDayTceReportingread-writecurrentFlag that enables/disables the reporting of RxBeiDay Tce threshold crossing.
1.3.6.1.4.1.21296.2.2.2.2.24.3NodeoduktClientCtpConformance
1.3.6.1.4.1.21296.2.2.2.2.24.3.1NodeoduktClientCtpCompliances
1.3.6.1.4.1.21296.2.2.2.2.24.3.1.1ComplianceoduktClientCtpCompliancecurrentDescribes the requirements for conformance to the ODUKTCLIENTCTP-MIB
1.3.6.1.4.1.21296.2.2.2.2.24.3.2NodeoduktClientCtpGroups
1.3.6.1.4.1.21296.2.2.2.2.24.3.2.1GroupoduktClientCtpGroupcurrentA collection of objects for managing the oduktClientCtp