MIB Viewer

MCC16-MIB

1254 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.868Nodetransition
1.3.6.1.4.1.868.1NodeproductId
1.3.6.1.4.1.868.1.4NodechassisProdsId
1.3.6.1.4.1.868.1.4.1NodechassisSlotTypes
1.3.6.1.4.1.868.1.4.1.1NodechSlMc20p
1.3.6.1.4.1.868.1.4.1.1.1NodeceTbtFrl03Id
1.3.6.1.4.1.868.1.4.1.1.2NodeceCxTbt04Id
1.3.6.1.4.1.868.1.4.1.1.3NodeceCxFrl04Id
1.3.6.1.4.1.868.1.4.1.1.4NodecfSmMm02Id
1.3.6.1.4.1.868.1.4.1.1.5NodecfSmMm05Id
1.3.6.1.4.1.868.1.4.1.1.6NodecaCf02Id
1.3.6.1.4.1.868.1.4.1.1.7NodecfSmMm06Id
1.3.6.1.4.1.868.1.4.1.1.8Nodect1e1Cf01Id
1.3.6.1.4.1.868.1.4.1.1.9NodeceRTxFx01Id
1.3.6.1.4.1.868.1.4.1.1.10Nodece100BtxFx04Id
1.3.6.1.4.1.868.1.4.1.1.12NodecpsCf01Id
1.3.6.1.4.1.868.1.4.1.1.13NodecbCf01Id
1.3.6.1.4.1.868.1.4.1.1.14NodecarCf01Id
1.3.6.1.4.1.868.1.4.1.1.15NodecarCf02Id
1.3.6.1.4.1.868.1.4.1.1.16NodecePswFx03Id
1.3.6.1.4.1.868.1.4.1.1.17NodecePswSx01Id
1.3.6.1.4.1.868.1.4.1.1.18NodecRs232Cf01Id
1.3.6.1.4.1.868.1.4.1.1.24NodecfSmMm04Id
1.3.6.1.4.1.868.1.4.1.1.26Nodece100BtxSx01Id
1.3.6.1.4.1.868.1.4.1.1.27Nodece100BtxFx04MtId
1.3.6.1.4.1.868.1.4.1.1.28NodecfdCd01Id
1.3.6.1.4.1.868.1.4.1.1.29NodectrCf01Id
1.3.6.1.4.1.868.1.4.1.1.30Nodece100BtxFrl03Id
1.3.6.1.4.1.868.1.4.1.1.31Nodemc20pEmptyId
1.3.6.1.4.1.868.1.4.1.1.32Nodemc20pErrorId
1.3.6.1.4.1.868.1.4.1.1.33Nodemc20pDblWideId
1.3.6.1.4.1.868.1.4.1.1.34NodechstrCf01Id
1.3.6.1.4.1.868.1.4.1.1.35NodeceTxSx02Id
1.3.6.1.4.1.868.1.4.1.1.36NodeceTbtFrl04Id
1.3.6.1.4.1.868.1.4.1.2NodechSlcps
1.3.6.1.4.1.868.1.4.1.2.1NodecpsmM100Id
1.3.6.1.4.1.868.1.4.1.2.1.111NodepSErrorA monitored MIB variable has changed from its 'operational' state to its 'error' state.
1.3.6.1.4.1.868.1.4.1.2.1.112NodepSErrorClearA monitored MIB variable has changed from its 'error' state to its 'operational' state.
1.3.6.1.4.1.868.1.4.1.2.1.113NodepSDeviceInsertedA new slide-in device (this includes some power supplies) was detected on the bus.
1.3.6.1.4.1.868.1.4.1.2.1.114NodepSDeviceRemovedA slide-in device that had previously been detected on the bus has not been heard from in a long time, and is presumed to have been physically removed.
1.3.6.1.4.1.868.1.4.1.2.1.115NodepSDeviceColdStartA slide-in device has indicated that it has rebooted. This is most common when the device is inserted into its slot, but in a few cases this trap indicates a w…
1.3.6.1.4.1.868.1.4.1.2.1.116NodepSPowerLostThe cabinet into which this management module is installed has lost power. Both the cabinet and the management module must support this feature for this trap t…
1.3.6.1.4.1.868.1.4.1.2.1.117NodepSCabinetAddedA new cabinet was detected on the bus.
1.3.6.1.4.1.868.1.4.1.2.1.118NodepSCabinetRemovedA cabinet that had previously been detected on the bus has not been heard from in a long time, and is presumed to have been physically removed.
1.3.6.1.4.1.868.1.4.1.2.2NodecpsmM200Id
1.3.6.1.4.1.868.1.4.1.2.3Nodecettf100Id
1.3.6.1.4.1.868.1.4.1.2.4Nodecfetf100Id
1.3.6.1.4.1.868.1.4.1.2.5Nodecfmff100Id
1.3.6.1.4.1.868.1.4.1.2.6Nodecpsmp100Id
1.3.6.1.4.1.868.1.4.1.2.7Nodecsetf100Id
1.3.6.1.4.1.868.1.4.1.2.8Nodecgetf100Id
1.3.6.1.4.1.868.1.4.1.2.9Nodecsdtf100Id
1.3.6.1.4.1.868.1.4.1.2.10Nodecpsmp110Id
1.3.6.1.4.1.868.1.4.1.2.11Nodecbftf100Id
1.3.6.1.4.1.868.1.4.1.2.12Nodecetct100Id
1.3.6.1.4.1.868.1.4.1.2.13Nodeccscf100Id
1.3.6.1.4.1.868.1.4.1.2.14Nodecfetf105Id
1.3.6.1.4.1.868.1.4.1.2.15Nodesmacf100PId
1.3.6.1.4.1.868.1.4.1.2.16Nodecpsld100Id
1.3.6.1.4.1.868.1.4.1.2.17Nodecdftf100Id
1.3.6.1.4.1.868.1.4.1.2.18Nodecpsvt100Id
1.3.6.1.4.1.868.1.4.1.2.19Nodecemtf100Id
1.3.6.1.4.1.868.1.4.1.2.20Nodecaptf100Id
1.3.6.1.4.1.868.1.4.1.2.21Nodecfetf205Id
1.3.6.1.4.1.868.1.4.1.2.22Nodecbftf150Id
1.3.6.1.4.1.868.1.4.1.2.23Nodecgfeb100Id
1.3.6.1.4.1.868.1.4.1.2.24Nodecrmfe100Id
1.3.6.1.4.1.868.1.4.1.2.25Nodecrs2f100Id
1.3.6.1.4.1.868.1.4.1.2.26Nodecrs4f100Id
1.3.6.1.4.1.868.1.4.1.2.27Nodecmefg100Id
1.3.6.1.4.1.868.1.4.1.2.1001NodecpsEmptyId
1.3.6.1.4.1.868.1.4.1.2.1002NodecpsDblWideId
1.3.6.1.4.1.868.1.4.1.2.1003NodecpsUnknownDeviceId
1.3.6.1.4.1.868.1.4.2NodechassisMcc16Id
1.3.6.1.4.1.868.1.4.2.101Nodemcc16ErrorA monitored MIB variable has changed from its 'operational' state to 'not present' or its 'error' state.
1.3.6.1.4.1.868.1.4.2.102Nodemcc16ErrorClearA monitored MIB variable has changed from a 'not present' or 'error' state to its 'operational' state.
1.3.6.1.4.1.868.1.4.2.103Nodemcc16PSStateThe power indication on a power supply has changed, or a power supply was non-operational at the time of a warm start.
1.3.6.1.4.1.868.1.4.3NodechassisCpsmc1800Id
1.3.6.1.4.1.868.1.4.4NodechassisCpsmc1850Id
1.3.6.1.4.1.868.1.4.5NodechassisCpsmc0800Id
1.3.6.1.4.1.868.1.4.6NodechassisCpsmc1300Id
1.3.6.1.4.1.868.1.4.7NodechassisCpsmc0200Id
1.3.6.1.4.1.868.1.4.8NodechassisSmacf100LCId
1.3.6.1.4.1.868.1.4.9NodechassisCpsmc1900Id
1.3.6.1.4.1.868.1.4.10NodechassisSmacf100Id
1.3.6.1.4.1.868.2Nodeproducts
1.3.6.1.4.1.868.2.4Nodechassis
1.3.6.1.4.1.868.2.4.1Nodecard
1.3.6.1.4.1.868.2.4.1.1NodeslotMc20p
1.3.6.1.4.1.868.2.4.1.1.1TableceTbtFrl03Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TBT-FRL-03 media converter, then entry 'n' in this table e…
1.3.6.1.4.1.868.2.4.1.1.1.1RowceTbtFrl03Entrynot-accessiblemandatoryState of LEDs on a single C/E-TBT-FRL-03
1.3.6.1.4.1.868.2.4.1.1.1.1.1ColumnceTbtFrl03Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.1.1.2ColumnceTbtFrl03FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.1.1.3ColumnceTbtFrl03FiberLinkread-onlymandatoryThe state of the converter's Fiber Link LED
1.3.6.1.4.1.868.2.4.1.1.1.1.4ColumnceTbtFrl03TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.1.1.5ColumnceTbtFrl03TPLinkread-onlymandatoryThe state of the converter's Twisted Pair Link LED
1.3.6.1.4.1.868.2.4.1.1.1.1.6ColumnceTbtFrl03Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.2TableceCxTbt04Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-CX-TBT-04 media converter, then entry 'n' in this table ex…
1.3.6.1.4.1.868.2.4.1.1.2.1RowceCxTbt04Entrynot-accessiblemandatoryState of LEDs on a single C/E-CX-TBT-04
1.3.6.1.4.1.868.2.4.1.1.2.1.1ColumnceCxTbt04Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.2.1.2ColumnceCxTbt04Jabberread-onlymandatoryThe state of the converter's Jabber LED
1.3.6.1.4.1.868.2.4.1.1.2.1.3ColumnceCxTbt04CoaxRecvread-onlymandatoryThe state of the converter's CoaxRecv LED
1.3.6.1.4.1.868.2.4.1.1.2.1.4ColumnceCxTbt04TPRecvread-onlymandatoryThe state of the converter's TPRecv LED
1.3.6.1.4.1.868.2.4.1.1.2.1.5ColumnceCxTbt04TPLinkread-onlymandatoryThe state of the converter's TPLink LED
1.3.6.1.4.1.868.2.4.1.1.2.1.6ColumnceCxTbt04Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.3TableceCxFrl04Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-CX-FRL-04 media converter, then entry 'n' in this table ex…
1.3.6.1.4.1.868.2.4.1.1.3.1RowceCxFrl04Entrynot-accessiblemandatoryState of LEDs on a single C/E-CX-FRL-04
1.3.6.1.4.1.868.2.4.1.1.3.1.1ColumnceCxFrl04Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.3.1.2ColumnceCxFrl04Jabberread-onlymandatoryThe state of the converter's Jabber LED
1.3.6.1.4.1.868.2.4.1.1.3.1.3ColumnceCxFrl04CoaxRecvread-onlymandatoryThe state of the converter's CoaxRecv LED
1.3.6.1.4.1.868.2.4.1.1.3.1.4ColumnceCxFrl04FLRecvread-onlymandatoryThe state of the converter's FLRecv LED
1.3.6.1.4.1.868.2.4.1.1.3.1.5ColumnceCxFrl04FLLinkread-onlymandatoryThe state of the converter's FLLink LED
1.3.6.1.4.1.868.2.4.1.1.3.1.6ColumnceCxFrl04Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.4TablecfSmMm02Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-02 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.4.1RowcfSmMm02Entrynot-accessiblemandatoryState of LEDs on a single C/F-SM-MM-02
1.3.6.1.4.1.868.2.4.1.1.4.1.1ColumncfSmMm02Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.4.1.2ColumncfSmMm02MMSignalDetectread-onlymandatoryThe state of the converter's MMSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.4.1.3ColumncfSmMm02SMSignalDetectread-onlymandatoryThe state of the converter's SMSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.4.1.4ColumncfSmMm02Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.5TablecfSmMm05Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-05 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.5.1RowcfSmMm05Entrynot-accessiblemandatoryState of LEDs on a single C/F-SM-MM-05
1.3.6.1.4.1.868.2.4.1.1.5.1.1ColumncfSmMm05Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.5.1.2ColumncfSmMm05SMSignalDetectread-onlymandatoryThe state of the converter's SMSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.5.1.3ColumncfSmMm05MMSignalDetectread-onlymandatoryThe state of the converter's MMSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.5.1.4ColumncfSmMm05Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.6TablecaCf02Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/A-CF-02 media converter, then entry 'n' in this table exists…
1.3.6.1.4.1.868.2.4.1.1.6.1RowcaCf02Entrynot-accessiblemandatoryState of LEDs on a single C/A-CF-02
1.3.6.1.4.1.868.2.4.1.1.6.1.1ColumncaCf02Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.6.1.2ColumncaCf02CopperSignalDetectread-onlymandatoryThe state of the converter's CopperSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.6.1.3ColumncaCf02FiberSignalDetectread-onlymandatoryThe state of the converter's FiberSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.6.1.4ColumncaCf02Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.7TablecfSmMm06Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-06 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.7.1RowcfSmMm06Entrynot-accessiblemandatoryState of LEDs on a single C/F-SM-MM-06
1.3.6.1.4.1.868.2.4.1.1.7.1.1ColumncfSmMm06Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.7.1.2ColumncfSmMm06MMSignalDetectread-onlymandatoryThe state of the converter's MMSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.7.1.3ColumncfSmMm06SMSignalDetectread-onlymandatoryThe state of the converter's SMSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.7.1.4ColumncfSmMm06Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.8Tablect1e1Cf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/T1E1-CF-01 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.8.1Rowct1e1Cf01Entrynot-accessiblemandatoryState of LEDs on a single C/T1E1-CF-01
1.3.6.1.4.1.868.2.4.1.1.8.1.1Columnct1e1Cf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.8.1.2Columnct1e1Cf01CopperSignalDetectread-onlymandatoryThe state of the converter's CopperSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.8.1.3Columnct1e1Cf01FiberSignalDetectread-onlymandatoryThe state of the converter's FiberSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.8.1.4Columnct1e1Cf01CoaxActiveread-onlymandatoryThe state of the converter's Coax Active LED
1.3.6.1.4.1.868.2.4.1.1.9TableceRTxFx01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-R-TX-FX-01 media converter, then entry 'n' in this table e…
1.3.6.1.4.1.868.2.4.1.1.9.1RowceRTxFx01Entrynot-accessiblemandatoryState of LEDs on a single C/E-R-TX-FX-01
1.3.6.1.4.1.868.2.4.1.1.9.1.1ColumnceRTxFx01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.9.1.2ColumnceRTxFx01TPPrimaryread-onlymandatoryThe state of the converter's Twisted Pair Primary LED
1.3.6.1.4.1.868.2.4.1.1.9.1.3ColumnceRTxFx01FiberPrimaryread-onlymandatoryThe state of the converter's Fiber Primary LED
1.3.6.1.4.1.868.2.4.1.1.9.1.4ColumnceRTxFx01TPSignalDetectread-onlymandatoryThe state of the converter's Twisted Pair Signal Detect LED
1.3.6.1.4.1.868.2.4.1.1.9.1.5ColumnceRTxFx01FiberSignalDetectread-onlymandatoryThe state of the converter's Fiber Signal Detect LED
1.3.6.1.4.1.868.2.4.1.1.10Tablece100BtxFx04Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-FX-04(ST/SC) media converter, then entry 'n' in th…
1.3.6.1.4.1.868.2.4.1.1.10.1Rowce100BtxFx04Entrynot-accessiblemandatoryState of LEDs on a single C/E-100-BTX-FX-04(ST/SC)
1.3.6.1.4.1.868.2.4.1.1.10.1.1Columnce100BtxFx04Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.10.1.2Columnce100BtxFx04TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.10.1.3Columnce100BtxFx04FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.10.1.4Columnce100BtxFx04TPSignalDetectread-onlymandatoryThe state of the converter's Twisted Pair signal detect LED
1.3.6.1.4.1.868.2.4.1.1.10.1.5Columnce100BtxFx04FiberSignalDetectread-onlymandatoryThe state of the converter's fiber signal detect LED
1.3.6.1.4.1.868.2.4.1.1.10.1.6Columnce100BtxFx04Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.12TablecpsCf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/PS-CF-01 media converter, then entry 'n' in this table exist…
1.3.6.1.4.1.868.2.4.1.1.12.1RowcpsCf01Entrynot-accessiblemandatoryState of LEDs on a single C/PS-CF-01
1.3.6.1.4.1.868.2.4.1.1.12.1.1ColumncpsCf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.12.1.2ColumncpsCf01FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.12.1.3ColumncpsCf01TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.12.1.4ColumncpsCf01Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.13TablecbCf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/B-CF-01 media converter, then entry 'n' in this table exists…
1.3.6.1.4.1.868.2.4.1.1.13.1RowcbCf01Entrynot-accessiblemandatoryState of LEDs on a single C/B-CF-01
1.3.6.1.4.1.868.2.4.1.1.13.1.1ColumncbCf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.13.1.2ColumncbCf01FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.13.1.3ColumncbCf01TPCoaxRecvread-onlymandatoryThe state of the converter's Twisted Pair/Coax Receive LED
1.3.6.1.4.1.868.2.4.1.1.13.1.4ColumncbCf01Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.14TablecarCf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/AR-CF-01 media converter, then entry 'n' in this table exist…
1.3.6.1.4.1.868.2.4.1.1.14.1RowcarCf01Entrynot-accessiblemandatoryState of LEDs on a single C/AR-CF-01
1.3.6.1.4.1.868.2.4.1.1.14.1.1ColumncarCf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.14.1.2ColumncarCf01FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.14.1.3ColumncarCf01TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.14.1.4ColumncarCf01Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.15TablecarCf02Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/AR-CF-02 media converter, then entry 'n' in this table exist…
1.3.6.1.4.1.868.2.4.1.1.15.1RowcarCf02Entrynot-accessiblemandatoryState of LEDs on a single C/AR-CF-02
1.3.6.1.4.1.868.2.4.1.1.15.1.1ColumncarCf02Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.15.1.2ColumncarCf02FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.15.1.3ColumncarCf02CoaxRecvread-onlymandatoryThe state of the converter's Coax Receive LED
1.3.6.1.4.1.868.2.4.1.1.15.1.4ColumncarCf02Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.16TablecePswFx03Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-PSW-FX-03 ethernet switch, then entry 'n' in this table ex…
1.3.6.1.4.1.868.2.4.1.1.16.1RowcePswFx03Entrynot-accessiblemandatoryState of LEDs on a single C/E-PSW-FX-03
1.3.6.1.4.1.868.2.4.1.1.16.1.1ColumncePswFx03Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.16.1.2ColumncePswFx03TPFullDuplexread-onlymandatoryThe state of the converter's Twisted Pair FDX LED
1.3.6.1.4.1.868.2.4.1.1.16.1.3ColumncePswFx03FiberFullDuplexread-onlymandatoryThe state of the converter's Fiber FDX LED
1.3.6.1.4.1.868.2.4.1.1.16.1.4ColumncePswFx03TPLinkread-onlymandatoryThe state of the converter's Twisted Pair Link LED
1.3.6.1.4.1.868.2.4.1.1.16.1.5ColumncePswFx03FiberLinkread-onlymandatoryThe state of the converter's Fiber Link LED
1.3.6.1.4.1.868.2.4.1.1.16.1.6ColumncePswFx03TP100Mbpsread-onlymandatoryThe state of the converter's Twisted Pair 100Mbps LED
1.3.6.1.4.1.868.2.4.1.1.17TablecePswSx01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-PSW-SX-01 ethernet switch, then entry 'n' in this table ex…
1.3.6.1.4.1.868.2.4.1.1.17.1RowcePswSx01Entrynot-accessiblemandatoryState of LEDs on a single C/E-PSW-SX-01
1.3.6.1.4.1.868.2.4.1.1.17.1.1ColumncePswSx01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.17.1.2ColumncePswSx01TPFullDuplexread-onlymandatoryThe state of the converter's Twisted Pair FDX LED
1.3.6.1.4.1.868.2.4.1.1.17.1.3ColumncePswSx01FiberFullDuplexread-onlymandatoryThe state of the converter's Fiber FDX LED
1.3.6.1.4.1.868.2.4.1.1.17.1.4ColumncePswSx01TPLinkread-onlymandatoryThe state of the converter's Twisted Pair Link LED
1.3.6.1.4.1.868.2.4.1.1.17.1.5ColumncePswSx01FiberLinkread-onlymandatoryThe state of the converter's Fiber Link LED
1.3.6.1.4.1.868.2.4.1.1.17.1.6ColumncePswSx01TP100Mbpsread-onlymandatoryThe state of the converter's Twisted Pair 100Mbps LED
1.3.6.1.4.1.868.2.4.1.1.18TablecRs232Cf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/RS232-CF-01 media converter, then entry 'n' in this table ex…
1.3.6.1.4.1.868.2.4.1.1.18.1RowcRs232Cf01Entrynot-accessiblemandatoryState of LEDs on a single C/RS232-CF-01
1.3.6.1.4.1.868.2.4.1.1.18.1.1ColumncRs232Cf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.18.1.2ColumncRs232Cf01FiberLockread-onlymandatoryThe state of the converter's Fiber Lock LED
1.3.6.1.4.1.868.2.4.1.1.24TablecfSmMm04Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-04 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.24.1RowcfSmMm04Entrynot-accessiblemandatoryState of LEDs on a single C/F-SM-MM-04
1.3.6.1.4.1.868.2.4.1.1.24.1.1ColumncfSmMm04Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.24.1.2ColumncfSmMm04MMSignalDetectread-onlymandatoryThe state of the converter's Multi-Mode signal detect LED
1.3.6.1.4.1.868.2.4.1.1.24.1.3ColumncfSmMm04SMSignalDetectread-onlymandatoryThe state of the converter's Single-Mode signal detect LED
1.3.6.1.4.1.868.2.4.1.1.24.1.4ColumncfSmMm04Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.26Tablece100BtxSx01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-SX-01 media converter, then entry 'n' in this tabl…
1.3.6.1.4.1.868.2.4.1.1.26.1Rowce100BtxSx01Entrynot-accessiblemandatoryState of LEDs on a single C/E-100-BTX-SX-01
1.3.6.1.4.1.868.2.4.1.1.26.1.1Columnce100BtxSx01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.26.1.2Columnce100BtxSx01TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.26.1.3Columnce100BtxSx01FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.26.1.4Columnce100BtxSx01TPSignalDetectread-onlymandatoryThe state of the converter's Twisted Pair signal detect LED
1.3.6.1.4.1.868.2.4.1.1.26.1.5Columnce100BtxSx01FiberSignalDetectread-onlymandatoryThe state of the converter's fiber signal detect LED
1.3.6.1.4.1.868.2.4.1.1.26.1.6Columnce100BtxSx01Powerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.27Tablece100BtxFx04MtTablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-FX-04(MT) media converter, then entry 'n' in this …
1.3.6.1.4.1.868.2.4.1.1.27.1Rowce100BtxFx04MtEntrynot-accessiblemandatoryState of LEDs on a single C/E-100-BTX-FX-04(MT)
1.3.6.1.4.1.868.2.4.1.1.27.1.1Columnce100BtxFx04MtIndexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.27.1.2Columnce100BtxFx04MtTPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.27.1.3Columnce100BtxFx04MtFiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.27.1.4Columnce100BtxFx04MtTPSignalDetectread-onlymandatoryThe state of the converter's Twisted Pair signal detect LED
1.3.6.1.4.1.868.2.4.1.1.27.1.5Columnce100BtxFx04MtFiberSignalDetectread-onlymandatoryThe state of the converter's fiber signal detect LED
1.3.6.1.4.1.868.2.4.1.1.27.1.6Columnce100BtxFx04MtPowerread-onlymandatoryThe state of the converter's Power LED
1.3.6.1.4.1.868.2.4.1.1.28TablecfdCd01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/FD-CD-01 media converter, then entry 'n' in this table exist…
1.3.6.1.4.1.868.2.4.1.1.28.1RowcfdCd01Entrynot-accessiblemandatoryState of LEDs on a single C/FD-CD-01
1.3.6.1.4.1.868.2.4.1.1.28.1.1ColumncfdCd01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.28.1.2ColumncfdCd01Lockread-onlymandatoryThe state of the converter's Lock LED
1.3.6.1.4.1.868.2.4.1.1.28.1.3ColumncfdCd01TPRecvread-onlymandatoryThe state of the converter's TPRecv LED
1.3.6.1.4.1.868.2.4.1.1.28.1.4ColumncfdCd01FiberRecvread-onlymandatoryThe state of the converter's FiberRecv LED
1.3.6.1.4.1.868.2.4.1.1.28.1.5ColumncfdCd01TPSignalDetectread-onlymandatoryThe state of the converter's TPSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.28.1.6ColumncfdCd01FiberSignalDetectread-onlymandatoryThe state of the converter's FiberSignalDetect LED
1.3.6.1.4.1.868.2.4.1.1.29TablectrCf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/TR-CF-01 media converter, then entry 'n' in this table exist…
1.3.6.1.4.1.868.2.4.1.1.29.1RowctrCf01Entrynot-accessiblemandatoryState of LEDs on a single C/TR-CF-01
1.3.6.1.4.1.868.2.4.1.1.29.1.1ColumnctrCf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.29.1.2ColumnctrCf01FiberinOKread-onlymandatoryThe state of the converter's FiberinOK LED
1.3.6.1.4.1.868.2.4.1.1.29.1.3ColumnctrCf01TPinOKread-onlymandatoryThe state of the converter's TPinOK LED
1.3.6.1.4.1.868.2.4.1.1.29.1.4ColumnctrCf01Insertedread-onlymandatoryThe state of the converter's Inserted LED
1.3.6.1.4.1.868.2.4.1.1.30Tablece100BtxFrl03Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100BTX-FRL-03 media converter, then entry 'n' in this tabl…
1.3.6.1.4.1.868.2.4.1.1.30.1Rowce100BtxFrl03Entrynot-accessiblemandatoryState of LEDs on a single C/E-100BTX-FRL-03
1.3.6.1.4.1.868.2.4.1.1.30.1.1Columnce100BtxFrl03Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.30.1.2Columnce100BtxFrl03Lockread-onlymandatoryThe state of the converter's signal lock pin
1.3.6.1.4.1.868.2.4.1.1.30.1.3Columnce100BtxFrl03TPRecvread-onlymandatoryThe state of the converter's Twisted pair receive LED
1.3.6.1.4.1.868.2.4.1.1.30.1.4Columnce100BtxFrl03FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.30.1.5Columnce100BtxFrl03TPSignalDetectread-onlymandatoryThe state of the converter's Twisted pair signal detect LED
1.3.6.1.4.1.868.2.4.1.1.30.1.6Columnce100BtxFrl03FiberSignalDetectread-onlymandatoryThe state of the converter's Fiber signal detect LED
1.3.6.1.4.1.868.2.4.1.1.34TablechstrCf01Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/HSTR-CF-01 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.34.1RowchstrCf01Entrynot-accessiblemandatoryState of LEDs on a single C/HSTR-CF-01
1.3.6.1.4.1.868.2.4.1.1.34.1.1ColumnchstrCf01Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.34.1.2ColumnchstrCf01TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.34.1.3ColumnchstrCf01FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.34.1.4ColumnchstrCf01TPSignalDetectread-onlymandatoryThe state of the converter's Twisted Pair signal detect LED
1.3.6.1.4.1.868.2.4.1.1.34.1.5ColumnchstrCf01FiberSignalDetectread-onlymandatoryThe state of the converter's fiber signal detect LED
1.3.6.1.4.1.868.2.4.1.1.35TableceTxSx02Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TX-SX-02 media converter, then entry 'n' in this table exi…
1.3.6.1.4.1.868.2.4.1.1.35.1RowceTxSx02Entrynot-accessiblemandatoryState of LEDs on a single C/E-TX-SX-02
1.3.6.1.4.1.868.2.4.1.1.35.1.1ColumnceTxSx02Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.35.1.2ColumnceTxSx02TPLinkread-onlymandatoryThe state of the converter's Twisted Pair Link LED
1.3.6.1.4.1.868.2.4.1.1.35.1.3ColumnceTxSx02FiberLinkread-onlymandatoryThe state of the converter's Fiber Link LED
1.3.6.1.4.1.868.2.4.1.1.35.1.4ColumnceTxSx02100Mbpsread-onlymandatoryThe state of the converter's 100 Megabit Per Second LED
1.3.6.1.4.1.868.2.4.1.1.36TableceTbtFrl04Tablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TBT-FRL-04 media converter, then entry 'n' in this table e…
1.3.6.1.4.1.868.2.4.1.1.36.1RowceTbtFrl04Entrynot-accessiblemandatoryState of LEDs on a single C/E-TBT-FRL-04
1.3.6.1.4.1.868.2.4.1.1.36.1.1ColumnceTbtFrl04Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.1.1.36.1.2ColumnceTbtFrl04FiberRecvread-onlymandatoryThe state of the converter's Fiber Receive LED
1.3.6.1.4.1.868.2.4.1.1.36.1.3ColumnceTbtFrl04FiberLinkread-onlymandatoryThe state of the converter's Fiber Link LED
1.3.6.1.4.1.868.2.4.1.1.36.1.4ColumnceTbtFrl04TPRecvread-onlymandatoryThe state of the converter's Twisted Pair Receive LED
1.3.6.1.4.1.868.2.4.1.1.36.1.5ColumnceTbtFrl04TPLinkread-onlymandatoryThe state of the converter's Twisted Pair Link LED
1.3.6.1.4.1.868.2.4.1.2NodeslotCps
1.3.6.1.4.1.868.2.4.1.2.1NodecpsSlotSummary
1.3.6.1.4.1.868.2.4.1.2.1.1TablecpsModuleTablenot-accessiblemandatoryA table from which one can extract the model number of any device in the stack, given the serial number (BIA) of the cabinet and the slot number in which the d…
1.3.6.1.4.1.868.2.4.1.2.1.1.1RowcpsModuleEntrynot-accessiblemandatoryThe model number entry for a single device.
1.3.6.1.4.1.868.2.4.1.2.1.1.1.1ColumncpsModuleBiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.1.1.1.2ColumncpsModuleSlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.1.1.1.3ColumncpsModuleModelread-onlymandatoryThe model number of the device. See OIDs under chSlcps
1.3.6.1.4.1.868.2.4.1.2.2NodecpsSlotDetail
1.3.6.1.4.1.868.2.4.1.2.2.1Tablecpsmm100Tablenot-accessiblemandatorySparse table containing one entry for each CPSMM100-200 and other CPSMM100-xxx Point System Base Management Module in the stack, indexed by cabinet serial numb…
1.3.6.1.4.1.868.2.4.1.2.2.1.1Rowcpsmm100Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMM100
1.3.6.1.4.1.868.2.4.1.2.2.1.1.1Columncpsmm100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.1.1.2Columncpsmm100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.1.1.3Columncpsmm100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.4Columncpsmm100Resetread-writemandatorySet this to reset(1) to cause the CPSMM100 to reboot.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.5Columncpsmm100SaveConfigread-writemandatorySet this to saveConfig(1) to force configuration changes made since the last saveConfig to be copied from RAM to flash memory. If changes are made to the confi…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.6Columncpsmm100HwRevisionread-onlymandatoryThe hardware revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.1.1.7Columncpsmm100SwRevisionread-onlymandatoryThe revision of the agent firmware for this device.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.8Columncpsmm100IPAddressread-writemandatoryThe IP Address of the Ethernet interface of this device
1.3.6.1.4.1.868.2.4.1.2.2.1.1.9Columncpsmm100SubnetMaskread-writemandatoryThe subnet mask used by the Ethernet interface of this device
1.3.6.1.4.1.868.2.4.1.2.2.1.1.10Columncpsmm100Gatewayread-writemandatoryThe IP gateway used by the Ethernet interface of this device
1.3.6.1.4.1.868.2.4.1.2.2.1.1.11Columncpsmm100IsPrimaryread-onlymandatoryIn a given Point System stack, multiple base management modules can be installed, but only one can be the Primary. The Primary is responsible for scanning the …
1.3.6.1.4.1.868.2.4.1.2.2.1.1.12Columncpsmm100WantPrimaryread-writemandatoryNormally, the Management Module installed in the cabinet with the lowest serial number (BIA) in the lowest (leftmost) slot that has fully established network c…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.13Columncpsmm100CanPrimaryread-onlymandatoryValue is yes(1) if this device is eligible to become the Primary Management Module. Currently, lack of IP/Ethernet connectivity is the only reason that a modul…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.14Columncpsmm100EthernetLinkread-onlymandatoryDoes the management interface of this management module have ethernet link?
1.3.6.1.4.1.868.2.4.1.2.2.1.1.15Columncpsmm100TntRIPread-onlymandatoryThis feature in obsolete as of 08/17/2001. Telnet 'trusted' IP address. Telnet access to the CPSMM100 can be limited to a single station by placing its IP addr…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.16Columncpsmm100TntRIPMaskread-onlymandatoryThis feature in obsolete as of 08/17/2001. Telnet 'trusted' address mask. See cpsmm100TntRIP. This value can be used to exclude bit positions from consideratio…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.17Columncpsmm100SNMPTrapMgrread-writemandatoryTraps generated by this management module will be sent to this IP address.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.18Columncpsmm100SNMPTrapIntervalread-writemandatoryFor future expansion, not currently implemented.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.19Columncpsmm100SysUpTimeread-onlymandatoryMirror of this Management Module's system.sysUpTime.0
1.3.6.1.4.1.868.2.4.1.2.2.1.1.20Columncpsmm100SysContactread-writemandatoryMirror of this Management Module's system.sysContact.0
1.3.6.1.4.1.868.2.4.1.2.2.1.1.21Columncpsmm100SysNameread-writemandatoryMirror of this Management Module's system.sysName.0
1.3.6.1.4.1.868.2.4.1.2.2.1.1.22Columncpsmm100SysLocationread-writemandatoryMirror of this Management Module's system.sysLocation.0
1.3.6.1.4.1.868.2.4.1.2.2.1.1.23Columncpsmm100CfgMatchread-writemandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.24Columncpsmm100SerialNumberread-onlymandatoryThe serial number of this device.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.25Columncpsmm100ICIFread-onlymandatoryMultiple Management Modules can be installed in a Point System stack. For each cabinet in the stack, exactly one module must be selected to communicate configu…
1.3.6.1.4.1.868.2.4.1.2.2.1.1.26Columncpsmm100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.1.1.27Columncpsmm100LastGaspread-onlymandatoryLast Gasp support for this device.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.28Columncpsmm100SNMPTrapMgr2read-writemandatoryTraps generated by this management module will be sent to this IP address.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.29Columncpsmm100SNMPTrapMgr3read-writemandatoryTraps generated by this management module will be sent to this IP address.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.30Columncpsmm100SNMPTrapMgr4read-writemandatoryTraps generated by this management module will be sent to this IP address.
1.3.6.1.4.1.868.2.4.1.2.2.1.1.31Columncpsmm100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.2Tablecpsmm200Tablenot-accessiblemandatorySparse table containing one entry for each CPSMM200-210 and other CPSMM200-xxx Point System Expansion Management Module in the stack, indexed by cabinet serial…
1.3.6.1.4.1.868.2.4.1.2.2.2.1Rowcpsmm200Entrynot-accessiblemandatoryStatus entries for a single cpsmm200. (The CPSMM200 has no configuration)
1.3.6.1.4.1.868.2.4.1.2.2.2.1.1Columncpsmm200BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.2.1.2Columncpsmm200SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.2.1.3Columncpsmm200SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.2.1.4Columncpsmm200ICIFread-onlymandatoryMultiple Management Modules can be installed in a Point System stack. For each cabinet in the stack, exactly one module must be selected to communicate configu…
1.3.6.1.4.1.868.2.4.1.2.2.2.1.5Columncpsmm200MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.3Tablecettf100Tablenot-accessiblemandatorySparse table containing one entry for each CETTF100 10Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and sl…
1.3.6.1.4.1.868.2.4.1.2.2.3.1Rowcettf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CETTF100
1.3.6.1.4.1.868.2.4.1.2.2.3.1.1Columncettf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.3.1.2Columncettf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.3.1.3Columncettf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.3.1.4Columncettf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.5Columncettf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.3.1.6Columncettf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.7Columncettf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.8Columncettf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.9Columncettf100TPLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.10Columncettf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.11Columncettf100Faultread-onlymandatoryValue is yes(1) when either TPLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.3.1.12Columncettf100TPActivityread-onlymandatoryNetwork traffic indicator for Copper side of this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.13Columncettf100FiberActivityread-onlymandatoryNetwork traffic indicator for Fiber side of this device
1.3.6.1.4.1.868.2.4.1.2.2.3.1.14Columncettf100AutoCrossread-writemandatoryEnable/Disable for automatic copper TX/RX pair correction
1.3.6.1.4.1.868.2.4.1.2.2.3.1.15Columncettf100LinkPassThroughread-writemandatoryEnable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr…
1.3.6.1.4.1.868.2.4.1.2.2.3.1.16Columncettf100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.3.1.17Columncettf100Enabledread-writemandatoryWhen this configuration item is set to no(2), the device passes no network traffic.
1.3.6.1.4.1.868.2.4.1.2.2.3.1.18Columncettf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.4Tablecfetf100Tablenot-accessiblemandatorySparse table containing one entry for each CFTEF100 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s…
1.3.6.1.4.1.868.2.4.1.2.2.4.1Rowcfetf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CFETF100
1.3.6.1.4.1.868.2.4.1.2.2.4.1.1Columncfetf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.4.1.2Columncfetf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.4.1.3Columncfetf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.4Columncfetf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.5Columncfetf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.6Columncfetf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.7Columncfetf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.8Columncfetf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.9Columncfetf100TPLinkread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.10Columncfetf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.11Columncfetf100Faultread-onlymandatoryValue is yes(1) when either TPLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.4.1.12Columncfetf100FastLinkPulseread-writemandatoryWhen set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the convert…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.13Columncfetf100Enabledread-writemandatoryWhen this configuration item is set to no(2), the device passes no network traffic.
1.3.6.1.4.1.868.2.4.1.2.2.4.1.14Columncfetf100Pauseread-writemandatoryThe Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.15Columncfetf100LinkPassThroughread-writemandatoryEnable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.16Columncfetf100AutoCrossread-writemandatoryEnable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode.
1.3.6.1.4.1.868.2.4.1.2.2.4.1.17Columncfetf100TPActivityread-onlymandatoryNetwork traffic indicator for Copper side of this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.18Columncfetf100FiberActivityread-onlymandatoryNetwork traffic indicator for Fiber side of this device
1.3.6.1.4.1.868.2.4.1.2.2.4.1.19Columncfetf100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.20Columncfetf100FarEndFaultread-writemandatoryFar End Fault configuration of this device. This setting can only be changed by the physical jumper setting on the slide in card, for some devices, if it is av…
1.3.6.1.4.1.868.2.4.1.2.2.4.1.21Columncfetf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.5Tablecfmff100Tablenot-accessiblemandatorySparse table containing one entry for each CFMFF100 SingleMode to MultiMode Fiber Media Converter in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.5.1Rowcfmff100Entrynot-accessiblemandatoryStatus and configuration entries for a single CFMFF100
1.3.6.1.4.1.868.2.4.1.2.2.5.1.1Columncfmff100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.5.1.2Columncfmff100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.5.1.3Columncfmff100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.5.1.4Columncfmff100MRevisionread-onlymandatoryThe marketing revision of the device
1.3.6.1.4.1.868.2.4.1.2.2.5.1.5Columncfmff100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.5.1.6Columncfmff100ConnAread-onlymandatoryThe style of SingleMode connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.5.1.7Columncfmff100ConnBread-onlymandatoryThe style of MultiMode connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.5.1.8Columncfmff100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.5.1.9Columncfmff100SMSignalread-onlymandatoryStatus of singlemode signal detect for this device
1.3.6.1.4.1.868.2.4.1.2.2.5.1.10Columncfmff100MMSignalread-onlymandatoryStatus of singlemode signal detect for this device
1.3.6.1.4.1.868.2.4.1.2.2.5.1.11Columncfmff100Enabledread-writemandatoryPorts on this device can be disabled individually. When this control is set to yes(1), the entire device is enabled. When it is set to noP1(2), the SingleMode …
1.3.6.1.4.1.868.2.4.1.2.2.5.1.12Columncfmff100PortShutOffread-onlymandatoryThis variable reflects the status of the DPT/OPP jumper on the board. This jumper controls the behavior of the converter when a loss of signal is detected. Whe…
1.3.6.1.4.1.868.2.4.1.2.2.5.1.13Columncfmff100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.5.1.14Columncfmff100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.6Tablecpsmp100Tablenot-accessiblemandatorySparse table containing one entry for each CPSMP100 IFO (Instant Fail-Over) Power Supply in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.6.1Rowcpsmp100Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMP100
1.3.6.1.4.1.868.2.4.1.2.2.6.1.1Columncpsmp100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.6.1.2Columncpsmp100SlotIndexread-onlymandatoryThe slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher.
1.3.6.1.4.1.868.2.4.1.2.2.6.1.3Columncpsmp100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.6.1.4Columncpsmp100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.6.1.5Columncpsmp100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.6.1.6Columncpsmp100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.6.1.7Columncpsmp100Moderead-writemandatoryWhen one power supply is set to master(1) and the other is set to slave(2), the master will supply all power to the cabinet, and the slave will take over if th…
1.3.6.1.4.1.868.2.4.1.2.2.6.1.8Columncpsmp100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.6.1.9Columncpsmp100RemoteFanread-onlymandatoryA Remote Fan is a device that fits in a power supply slot but contains no power supply, only a fan. These devices are not manageable, but if present they will …
1.3.6.1.4.1.868.2.4.1.2.2.6.1.10Columncpsmp100PowerOKread-onlymandatoryThis variable has the value yes(1) any time this supply is capable of supplying at least 11.6 volts to the cabinet. Note that a value of no(2) does not necessa…
1.3.6.1.4.1.868.2.4.1.2.2.6.1.11Columncpsmp100InUseread-onlymandatoryValue is yes(1) when this supply is currently selected to supply power to the cabinet.
1.3.6.1.4.1.868.2.4.1.2.2.6.1.12Columncpsmp100ChassisPowerread-onlymandatoryPower currently supplied to the cabinet, in milliwatts
1.3.6.1.4.1.868.2.4.1.2.2.6.1.13Columncpsmp100ChassisTempread-onlymandatoryThe temperature inside the cabinet as detected by the power supply, in tenths of degrees centigrade
1.3.6.1.4.1.868.2.4.1.2.2.6.1.14Columncpsmp100RFanFaultread-onlymandatoryNormally no(2), this value changes to yes(1) when an installed Remote fan is drawing excessive current or none at all.
1.3.6.1.4.1.868.2.4.1.2.2.6.1.15Columncpsmp100LFanFaultread-onlymandatoryNormally no(2), this value changes to yes(1) when the Local fan is drawing excessive current or none at all.
1.3.6.1.4.1.868.2.4.1.2.2.6.1.16Columncpsmp100SupplyTyperead-onlymandatoryThe supply voltage that this unit is designed to accept. If AC(1), the supply accepts 90-260VAC, 47 to 400Hz. If DC48(2), the supply accepts 38-75VDC.
1.3.6.1.4.1.868.2.4.1.2.2.6.1.17Columncpsmp100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.7Tablecsetf100Tablenot-accessiblemandatorySparse table containing one entry for each CSETF100 10/100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number an…
1.3.6.1.4.1.868.2.4.1.2.2.7.1Rowcsetf100Entrynot-accessiblemandatoryOne table entry per piece of management module information. Entry 'n' does not exist.
1.3.6.1.4.1.868.2.4.1.2.2.7.1.1Columncsetf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.7.1.2Columncsetf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.7.1.3Columncsetf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.7.1.4Columncsetf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.5Columncsetf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.7.1.6Columncsetf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.7Columncsetf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.8Columncsetf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.9Columncsetf100TPLinkread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.10Columncsetf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.11Columncsetf100AutoCrossread-writemandatoryEnable/Disable for automatic copper TX/RX pair correction
1.3.6.1.4.1.868.2.4.1.2.2.7.1.12Columncsetf100SpeedConfigread-writemandatoryThis variable allows the user to set the requested data transfer rate for this converter.
1.3.6.1.4.1.868.2.4.1.2.2.7.1.13Columncsetf100Speed100Mbpsread-onlymandatoryThis variable reports the current data transfer rate for this converter.
1.3.6.1.4.1.868.2.4.1.2.2.7.1.14Columncsetf100TPActivityread-onlymandatoryNetwork traffic indicator for Copper side of this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.15Columncsetf100FiberActivityread-onlymandatoryNetwork traffic indicator for Fiber side of this device
1.3.6.1.4.1.868.2.4.1.2.2.7.1.16Columncsetf100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.7.1.17Columncsetf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.8Tablecgetf100Tablenot-accessiblemandatorySparse table containing one entry for each CGETF100 Gigabit Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s…
1.3.6.1.4.1.868.2.4.1.2.2.8.1Rowcgetf100Entrynot-accessiblemandatoryOne table entry per piece of management module information. Entry 'n' does not exist.
1.3.6.1.4.1.868.2.4.1.2.2.8.1.1Columncgetf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.8.1.2Columncgetf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.8.1.3Columncgetf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.4Columncgetf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.8.1.5Columncgetf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.6Columncgetf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.8.1.7Columncgetf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.8.1.8Columncgetf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.8.1.9Columncgetf100TPLinkread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.8.1.10Columncgetf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.8.1.11Columncgetf100Faultread-onlymandatoryValue is yes(1) when either TPLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.8.1.12Columncgetf100Enabledread-writemandatoryWhen this variable is set to no(1), the device allows no traffic to pass.
1.3.6.1.4.1.868.2.4.1.2.2.8.1.13Columncgetf100Pauseread-writemandatoryEnable/Disable control for the advertising of Pause capability on the copper interface. This MIB variable is retained for compatibility with older applications…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.14Columncgetf100LinkPassThroughread-writemandatoryEnable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.15Columncgetf100FullDuplexread-writemandatoryControls advertizing of duplex capability for the copper side of the converter. When set to fullDuplex(1), the converter advertizes full duplex capability. Whe…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.16Columncgetf100ClockMasterread-onlymandatoryWhen yes(1), the converter is supplying clock to the twisted pair. When no(2), the remote supplies the clock.
1.3.6.1.4.1.868.2.4.1.2.2.8.1.17Columncgetf100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.18Columncgetf100TPLengthread-onlymandatoryTwisted-pair length estimated via the converter's internal Time Domain Reflectometer. 1 means less than 50 meters, 2 means 50 to 80 meters, 3 means 80 to 110 m…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.19Columncgetf100FiberAutoNegotread-writemandatoryFiber port autonegotiation configuration.
1.3.6.1.4.1.868.2.4.1.2.2.8.1.20Columncgetf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.8.1.21Columncgetf100PauseTyperead-writemandatoryEnable/Disable control for the advertising of Pause capability on the copper interface. This MIB variable is only functional on CGETF100 devices that support a…
1.3.6.1.4.1.868.2.4.1.2.2.9Tablecsdtf100Tablenot-accessiblemandatorySparse table containing one entry for each CSDTF100 T1/E1 Copper to Fiber Media Converter in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.9.1Rowcsdtf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CSDTF100
1.3.6.1.4.1.868.2.4.1.2.2.9.1.1Columncsdtf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.9.1.2Columncsdtf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.9.1.3Columncsdtf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.4Columncsdtf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.9.1.5Columncsdtf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.6Columncsdtf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.9.1.7Columncsdtf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.9.1.8Columncsdtf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.9.1.9Columncsdtf100CopperLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.9.1.10Columncsdtf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.9.1.11Columncsdtf100Faultread-onlymandatoryValue is yes(1) when either CopperLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.9.1.12Columncsdtf100TAOSFiberread-writemandatoryTransmit All Ones on Fiber as an error signal when Copper interface is down. When this error signal is transmitted, the AIS of the device on the other end is a…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.13Columncsdtf100TAOSCopperread-writemandatoryTransmit All Ones on Copper as an error signal when Fiber interface is down. When this error signal is transmitted, the AIS of the device on the other end is a…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.14Columncsdtf100AISFiberread-onlymandatoryAlarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.15Columncsdtf100AISCopperread-onlymandatoryAlarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.16Columncsdtf100CopperLoopbackread-writemandatoryEnable loopback on the copper interface. Copper Loopback causes all data that is sent to the copper interface to be transmitted back out the copper interface. …
1.3.6.1.4.1.868.2.4.1.2.2.9.1.17Columncsdtf100CopperLongHaulread-onlymandatoryThis variable indicates the current position of the device's long/short haul configuration switch.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.18Columncsdtf100T1E1read-onlymandatoryThis variable indicates whether the current device is the T1 or the E1 version.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.19Columncsdtf100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.20Columncsdtf100TPCoaxread-onlymandatoryIndicates the connector type installed on the copper interface. For E1 converters, this can be either Twisted Pair or Coax. For T1, it is always Twisted Pair.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.21Columncsdtf100CopperLineBuildoutread-onlymandatoryThe characteristics of the copper interface
1.3.6.1.4.1.868.2.4.1.2.2.9.1.22Columncsdtf100FiberLoopbackread-writemandatoryEnable loopback on the Fiber interface. Fiber Loopback causes all data that is sent to the Fiber interface to be transmitted back out the Fiber interface.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.23Columncsdtf100RmtSupportedread-onlymandatoryHas the value yes(1) if this converter is capable of managing the media converter at the remote end of the fiber.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.24Columncsdtf100RmtDetectedread-onlymandatoryHas the value yes(1) if management communcations have been established with a remote media converter. Always no(2) if TAOS is enabled or the remote converter d…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.25Columncsdtf100RmtMRevisionread-onlymandatoryRemote Marketing Revision. Same as csdtf100MRevision, only for the remote device.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.26Columncsdtf100RmtSerialNumberread-onlymandatorySerial Number reported by remote device.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.27Columncsdtf100RmtConnAread-onlymandatoryThe style of Fiber connector reported by remote device.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.28Columncsdtf100RmtConnBread-onlymandatoryThe style of Fiber connector reported by remote device.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.29Columncsdtf100RmtCopperLinkread-onlymandatoryLink status of remote Copper Port.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.30Columncsdtf100RmtFiberLinkread-onlymandatoryLink status of remote Fiber Port.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.31Columncsdtf100RmtFaultread-onlymandatoryRemote Fault status. Value is yes(1) when either CopperLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.9.1.32Columncsdtf100RmtTAOSFiberread-writemandatoryRemote Fiber TAOS configuration. Transmit All Ones on Fiber as an error signal when Copper interface is down. When this error signal is transmitted, the AIS of…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.33Columncsdtf100RmtTAOSCopperread-writemandatoryRemote Copper TAOS configuration. Transmit All Ones on Copper as an error signal when Fiber interface is down. When this error signal is transmitted, the AIS o…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.34Columncsdtf100RmtAISFiberread-onlymandatoryRemote Fiber AIS status. Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.35Columncsdtf100RmtAISCopperread-onlymandatoryRemote Copper AIS status. Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alar…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.36Columncsdtf100RmtCopperLoopbackread-writemandatoryRemote Copper Loopback configuration. Enable loopback on the copper interface. Copper Loopback causes all data that is sent to the copper interface to be trans…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.37Columncsdtf100RmtCopperLongHaulread-onlymandatoryThis variable indicates the current position of the remote device's Short/Long haul configuration switch.
1.3.6.1.4.1.868.2.4.1.2.2.9.1.38Columncsdtf100RmtConfigModeread-onlymandatoryRemote Configuration Mode. This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management …
1.3.6.1.4.1.868.2.4.1.2.2.9.1.39Columncsdtf100RmtTPCoaxread-onlymandatoryIndicates the connector type installed on the remote copper interface. For E1 converters, this can be either Twisted Pair or Coax. For T1, it is always Twisted…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.40Columncsdtf100RmtCopperLineBuildoutread-onlymandatoryThe electrical characteristics of the remote Copper interface. Values are the same as the values for csdtf100CopperLineBuildout(21)
1.3.6.1.4.1.868.2.4.1.2.2.9.1.41Columncsdtf100RmtFiberLoopbackread-writemandatoryEnable loopback on the remote Fiber interface. Fiber Loopback causes all data that is sent to the Fiber interface to be transmitted back out the Fiber interfac…
1.3.6.1.4.1.868.2.4.1.2.2.9.1.42Columncsdtf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.10Tablecpsmp110Tablenot-accessiblemandatorySparse table containing one entry for each CPSMP110 IFO (Instant Fail-Over) Power Supply in the stack. indexed by sub-device index, cabinet serial number, and …
1.3.6.1.4.1.868.2.4.1.2.2.10.1Rowcpsmp110Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMP100
1.3.6.1.4.1.868.2.4.1.2.2.10.1.1Columncpsmp110SubDeviceIndexread-onlymandatoryGenerally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.2Columncpsmp110BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for …
1.3.6.1.4.1.868.2.4.1.2.2.10.1.3Columncpsmp110SlotIndexread-onlymandatoryThe slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placehol…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.4Columncpsmp110Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.5Columncpsmp110MRevisionread-onlymandatoryThe marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.6Columncpsmp110CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.7Columncpsmp110SerialNumberread-onlymandatoryThe serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.8Columncpsmp110ConfigModeread-onlymandatoryThis device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.9Columncpsmp110MasterTempFaultread-onlymandatoryThe master temperature fault indicator for this device. A value of yes(1) indicates that at least one temperature sensor encountered a fault condition since th…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.10Columncpsmp110MasterCurrentFaultread-onlymandatoryThe master current fault indicator for this device. A value of yes(1) indicates that at least one current sensor encountered a fault condition since the last t…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.11Columncpsmp110MasterFanFaultread-onlymandatoryThe master fan fault indicator for this device. A value of yes(1) indicates that at least one fan current sensor encountered a fault condition since the last t…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.12Columncpsmp110FirmwareRevisionread-onlymandatoryThe firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.13Columncpsmp110PSSupplyTblread-onlymandatoryThe supply voltage that this unit is designed to accept. If AC(1), the supply accepts VAC. If DC(2), the supply accepts. A single CPSMP110 control unit can sup…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.14Columncpsmp110PSRoleTblread-writemandatorySome power supplies support a Master/Slave relationship: When one power supply is set to master(1) and the other is set to slave(2), the master will supply all…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.15Columncpsmp110PSReadyTblread-onlymandatoryThe readiness of this power supply module. A value of yes(1) indicates the module is ready to supply power to the cabinet. A value of no(2) indicates that the …
1.3.6.1.4.1.868.2.4.1.2.2.10.1.16Columncpsmp110PSInUseTblread-onlymandatoryThe use status of this power supply module. A value of yes(1) indicates the module is supplying power to the cabinet. This variable is useful in configurations…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.17Columncpsmp110TemperatureTblread-onlymandatoryThe temperature, in tenths of degrees centigrade, read by this temperature sensor. A single CPSMP110 control unit can support multiple subdevices of this type.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.18Columncpsmp110CurrentTblread-onlymandatoryThe current, in milliwatts, read by this current sensor. A single CPSMP110 control unit can support multiple subdevices of this type.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.19Columncpsmp110FanStatusTblread-onlymandatoryThe status of a fan. A value of fault(2) indicates that the control unit has detected a problem with the fan, usually that it is is drawing excessive current. …
1.3.6.1.4.1.868.2.4.1.2.2.10.1.20Columncpsmp110TempFaultTblread-onlymandatoryEach entry in this column corresponds to an entry with the same indices in cpsmp110TemperatureTable. It indicates whether or not the temperature read by the se…
1.3.6.1.4.1.868.2.4.1.2.2.10.1.21Columncpsmp110CurrFaultTblread-onlymandatoryEach entry in this column corresponds to an entry with the same indices in cpsmp110CurrentTable. It indicates whether or not the current read by the sensor is …
1.3.6.1.4.1.868.2.4.1.2.2.10.1.22Columncpsmp110PSCountread-onlymandatoryThe maximum number of power supplies supported in this configuration.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.23Columncpsmp110TempSensorCountread-onlymandatoryThe number of temperature sensors supported in this device.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.24Columncpsmp110CurrSensorCountread-onlymandatoryThe number of current sensors supported in this device.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.25Columncpsmp110FanCountread-onlymandatoryThe number of fans supported in this device.
1.3.6.1.4.1.868.2.4.1.2.2.10.1.26Columncpsmp110CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.11Tablecbftf100Tablenot-accessiblemandatorySparse table containing one entry for each CBFTF100 switch in the stack. Indexed by sub-device index, cabinet serial number, and slot. Note that some columns o…
1.3.6.1.4.1.868.2.4.1.2.2.11.1Rowcbftf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CBFTF100
1.3.6.1.4.1.868.2.4.1.2.2.11.1.1Columncbftf100SubDeviceIndexread-onlymandatoryGenerally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.2Columncbftf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for …
1.3.6.1.4.1.868.2.4.1.2.2.11.1.3Columncbftf100SlotIndexread-onlymandatoryThe slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placehol…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.4Columncbftf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.5Columncbftf100MRevisionread-onlymandatoryThe marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.6Columncbftf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.7Columncbftf100SerialNumberread-onlymandatoryThe serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.8Columncbftf100ConfigModeread-onlymandatoryThis device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.9Columncbftf100FirmwareRevisionread-onlymandatoryThe firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.10Columncbftf100SelfTestFailedread-onlymandatoryThis variable indicates the status of the pass/fail power on test. If the power on test fails, normal operation of this device is probably not possible.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.11Columncbftf100SpanningTreeread-writemandatoryThis variable allows the agent to enable or disable Spanning Tree if it is supported. Not all versions of the hardware support Spanning Tree.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.12Columncbftf100MirrorCfgread-writemandatoryGlobal enable/disable for mirror port functionality. When this variable is set to disabled, the values of cbftf100MirrorSelTbl, cbftf100MirrorInTbl, and cbftf1…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.13Columncbftf100SACMasterCfgread-writemandatoryGlobal enable/disable for Source Address Change detection functionality. When this variable is set to disabled the values in cbtf100SACCfgTbl are ignored.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.14Columncbftf100FormFactorread-onlymandatoryA code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number of physical connectors present…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.15Columncbftf100AutoNegotTblread-writemandatoryEnables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are multiple subdevices in this table, …
1.3.6.1.4.1.868.2.4.1.2.2.11.1.16Columncbftf100FullDuplexTblread-writemandatoryIn most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports wit…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.17Columncbftf100100MbpsTblread-writemandatoryIn most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, this is a status indication sho…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.18Columncbftf100Adv10HDXTblread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, half duplex. This setting is not supported on fiber p…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.19Columncbftf100Adv10FDXTblread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, full duplex. This setting is not supported on fiber p…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.20Columncbftf100Adv100HDXTblread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, half duplex. This setting is not supported on fiber …
1.3.6.1.4.1.868.2.4.1.2.2.11.1.21Columncbftf100Adv100FDXTblread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, full duplex. This setting is not supported on fiber …
1.3.6.1.4.1.868.2.4.1.2.2.11.1.22Columncbftf100CrossTblread-writemandatoryConfiguration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs if necessary. If autonegotiat…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.23Columncbftf100PauseCfgTblread-writemandatoryThe Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. A setting of enabled(1) causes this port to advertis…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.24Columncbftf100PauseStatTblread-onlymandatoryThe Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. A value of paused(1) indicated the port is in a paus…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.25Columncbftf100FarEndFaultTblread-writemandatoryWhen Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform the device at the far end of the…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.26Columncbftf100ConnectorTblread-onlymandatoryThe style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.27Columncbftf100SACCfgTblread-writemandatoryThis configuration setting controls whether changes in source MAC address are reported. When set to enabled(1), a change in MAC address will result in a moment…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.28Columncbftf100SACStatTblread-onlymandatoryThis status value indicates whether or not the source MAC address attached to this port changed in the last polling period. This value tends to change quite qu…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.29Columncbftf100MirrorSelTblread-writemandatoryThis configuration setting allows a mirror port to be selected. The selected port will re-transmit copies of all packets transmitted on ports whose MirrorOutTb…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.30Columncbftf100MirrorInTblread-writemandatoryThis configuration setting allows a mirror source port to be selected. All packets received on each port with a MirrorInTbl setting of mirrorIn(1) will be retr…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.31Columncbftf100MirrorOutTblread-writemandatoryThis configuration setting allows a mirror source port to be selected. All packets transmitted on each port with a MirrorInTbl setting of mirrorOut(1) will be …
1.3.6.1.4.1.868.2.4.1.2.2.11.1.32Columncbftf100LinkTblread-onlymandatoryThis table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.33Columncbftf100PortCountread-onlymandatoryA count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch.
1.3.6.1.4.1.868.2.4.1.2.2.11.1.34Columncbftf100LinkPassThroughread-writemandatoryIf Link Passthrough is enabled on a port, loss of link on the opposite port will be propegated through to this port so that the switch does not prevent one end…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.35Columncbftf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.11.1.36Columncbftf100RedundantPathread-onlymandatoryThis variable shows the status of the redundant fiber capability. If the value is enabled(1), this means that the hardware switch to enable redundant fiber is …
1.3.6.1.4.1.868.2.4.1.2.2.12Tablecetct100Tablenot-accessiblemandatorySparse table containing one entry for each CETCT100 10Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and sl…
1.3.6.1.4.1.868.2.4.1.2.2.12.1Rowcetct100Entrynot-accessiblemandatoryStatus and configuration entries for a single CETCT100
1.3.6.1.4.1.868.2.4.1.2.2.12.1.1Columncetct100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.12.1.2Columncetct100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.12.1.3Columncetct100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.12.1.4Columncetct100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.12.1.5Columncetct100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.12.1.6Columncetct100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.12.1.7Columncetct100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.12.1.8Columncetct100FirmwareRevisionread-onlymandatoryThe firmware revision level for this device.
1.3.6.1.4.1.868.2.4.1.2.2.12.1.9Columncetct100TPLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.12.1.10Columncetct100Collisionread-onlymandatoryThis status variable indicates whether or not an Ethernet collision occurred during the most recent polling cycle.
1.3.6.1.4.1.868.2.4.1.2.2.12.1.11Columncetct100CoaxActivityread-onlymandatoryThis status variable indicates whether or not Ethernet traffic was detected on the Coax interface during the most recent polling cycle.
1.3.6.1.4.1.868.2.4.1.2.2.12.1.12Columncetct100TPActivityread-onlymandatoryThis status variable indicates whether or not Ethernet traffic was detected on the Twisted Pair interface during the most recent polling cycle.
1.3.6.1.4.1.868.2.4.1.2.2.12.1.13Columncetct100CollisionsPerMinuteread-onlymandatoryThe number of Ethernet collisions that occurred during the most recently completed measured minute. Every 60 seconds, the device moves its previous collision c…
1.3.6.1.4.1.868.2.4.1.2.2.12.1.14Columncetct100CollisionsPerHourread-onlymandatoryThe number of Ethernet collisions that occurred during the most recently completed measured hour. Every 60 minutes, the device moves its previous collision cou…
1.3.6.1.4.1.868.2.4.1.2.2.12.1.15Columncetct100ConnAread-onlymandatoryThe style of media connector built into this device.
1.3.6.1.4.1.868.2.4.1.2.2.12.1.16Columncetct100ConnBread-onlymandatoryThe style of media connector built into this device.
1.3.6.1.4.1.868.2.4.1.2.2.12.1.17Columncetct100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.13Tableccscf100Tablenot-accessiblemandatorySparse table containing one entry for each ccscf100 T3/E3 Copper to Fiber Media Converter in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.13.1Rowccscf100Entrynot-accessiblemandatoryStatus and configuration entries for a single ccscf100
1.3.6.1.4.1.868.2.4.1.2.2.13.1.1Columnccscf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.13.1.2Columnccscf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.13.1.3Columnccscf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.13.1.4Columnccscf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.13.1.5Columnccscf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.13.1.6Columnccscf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.13.1.7Columnccscf100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.13.1.8Columnccscf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.13.1.9Columnccscf100CopperLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.13.1.10Columnccscf100AISFiberread-onlymandatoryAlarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition.
1.3.6.1.4.1.868.2.4.1.2.2.13.1.11Columnccscf100AISCopperread-onlymandatoryAlarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition.
1.3.6.1.4.1.868.2.4.1.2.2.13.1.12Columnccscf100DS3LineBuildoutread-writemandatoryThe characteristics of the copper interface
1.3.6.1.4.1.868.2.4.1.2.2.13.1.13Columnccscf100E3DS3read-onlymandatoryThis variable indicates whether the current device is the T1 or the E1 version.
1.3.6.1.4.1.868.2.4.1.2.2.13.1.14Columnccscf100CopperLoopbackread-writemandatoryEnable loopback on the copper interface.
1.3.6.1.4.1.868.2.4.1.2.2.13.1.15Columnccscf100FiberLoopbackread-writemandatoryEnable loopback on the copper interface.
1.3.6.1.4.1.868.2.4.1.2.2.13.1.16Columnccscf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.13.1.17Columnccscf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.13.1.18Columnccscf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.14Tablecfetf105Tablenot-accessiblemandatorySparse table containing one entry for each CFTEF105 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s…
1.3.6.1.4.1.868.2.4.1.2.2.14.1Rowcfetf105Entrynot-accessiblemandatoryStatus and configuration entries for a single CFETF105
1.3.6.1.4.1.868.2.4.1.2.2.14.1.1Columncfetf105BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.14.1.2Columncfetf105SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.14.1.3Columncfetf105Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.14.1.4Columncfetf105MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.5Columncfetf105CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.14.1.6Columncfetf105SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.7Columncfetf105ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.8Columncfetf105ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.9Columncfetf105TPLinkread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.10Columncfetf105FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.11Columncfetf105AutoNegotread-writemandatoryEnable/Disable Autonegotiation
1.3.6.1.4.1.868.2.4.1.2.2.14.1.12Columncfetf105LinkPassThroughread-writemandatoryEnable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr…
1.3.6.1.4.1.868.2.4.1.2.2.14.1.13Columncfetf105AutoCrossread-writemandatoryEnable/Disable for automatic copper TX/RX pair correction
1.3.6.1.4.1.868.2.4.1.2.2.14.1.14Columncfetf105TPActivityread-onlymandatoryNetwork traffic indicator for Copper side of this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.15Columncfetf105FiberActivityread-onlymandatoryNetwork traffic indicator for Fiber side of this device
1.3.6.1.4.1.868.2.4.1.2.2.14.1.16Columncfetf105ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.14.1.17Columncfetf105CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.15Tablesmacf100PTablenot-accessiblemandatorySparse table containing one entry for each SMACF100P virtual slide-in device. This table dexcribes ONE port on a SMACFxxx colony switch
1.3.6.1.4.1.868.2.4.1.2.2.15.1Rowsmacf100PEntrynot-accessiblemandatoryStatus and configuration entries for a single SMACF100P
1.3.6.1.4.1.868.2.4.1.2.2.15.1.1Columnsmacf100PSubDeviceIndexread-onlymandatoryGenerally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices. T…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.2Columnsmacf100PBiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.15.1.3Columnsmacf100PSlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.15.1.4Columnsmacf100PGroupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.5Columnsmacf100PCfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.6Columnsmacf100PConnAread-onlymandatoryThe style of Fiber or Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.15.1.7Columnsmacf100PLinkread-onlymandatoryStatus of Port Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.15.1.8Columnsmacf100P100Mbpsread-writemandatoryCommunication speed for this port.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.9Columnsmacf100PFullDuplexread-writemandatoryIn most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports wit…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.10Columnsmacf100PSACStatread-onlymandatoryThis status value indicates whether or not the source MAC address attached to this port changed in the last polling period. This value tends to change quite qu…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.11Columnsmacf100PEnabledread-writemandatoryStatus of of this Port. A value of yes(1) indicates this port is 'enabled'. A value of no(2) indicates this port is 'disabled'.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.12Columnsmacf100PAutoNegotread-writemandatoryEnables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.13Columnsmacf100PAdv10HDXread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, half duplex. This setting is not supported on fiber p…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.14Columnsmacf100PAdv10FDXread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, full duplex. This setting is not supported on fiber p…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.15Columnsmacf100PAdv100HDXread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, half duplex. This setting is not supported on fiber …
1.3.6.1.4.1.868.2.4.1.2.2.15.1.16Columnsmacf100PAdv100FDXread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, full duplex. This setting is not supported on fiber …
1.3.6.1.4.1.868.2.4.1.2.2.15.1.17Columnsmacf100PSTPStateread-writemandatoryPort spanning tree state.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.18Columnsmacf100PLastMACread-onlymandatoryLast MAC Address this port communicated with.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.19Columnsmacf100PFarEndFaultCfgread-writemandatoryFar end fault configuration of this Port.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.20Columnsmacf100PFarEndFaultStatread-onlymandatoryFar end fault status of this port.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.21Columnsmacf100PTxOctetsread-onlymandatoryThe number of bytes of data transmitted through this interface.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.22Columnsmacf100PWrapTxOctetsread-onlymandatoryThe number of times that the unsigned 32-bit smacf100PTxOctets(21) MIB variable has wrapped.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.23Columnsmacf100PRxOctetsread-onlymandatoryThe number of bytes of data received through this interface.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.24Columnsmacf100PWrapRxOctetsread-onlymandatoryThe number of times that the unsigned 32-bit smacf100PRxOctets(23) MIB variable has wrapped.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.25Columnsmacf100PSACCfgread-writemandatorySource Address Change detection configuration. Enables or Disables the generation of traps related to source address change for this port. When disabled, the s…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.26Columnsmacf100PBlockMgmtread-writemandatoryThrough this variable and others, the SMACF100 supports port- based VLANs. The SMACF100 will pass tags for IEEE 802.3ac VLANs, but will neither insert nor stri…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.27Columnsmacf100PBlockPortread-writemandatoryThrough this variable and others, the SMACF100 supports port- based VLANs. The SMACF100 will pass tags for IEEE 802.3ac VLANs, but will neither insert nor stri…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.28Columnsmacf100PTxDropPktsread-onlymandatoryThis counter is incremented every time a transmit packet is dropped due to lack of resources (e.g. transmit FIFO underflow), or an internal MAC sublayer transm…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.29Columnsmacf100PTxBroadcastPktsread-onlymandatoryThe number of good packets transmitted by this port that are directed to a broadcast address. This counter includes neither errored broadcast packets nor valid…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.30Columnsmacf100PTxMulticastPktsread-onlymandatoryThe number of good packets transmitted by this port that are directed to a multicast address. This counter includes neither errored multicast packets nor valid…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.31Columnsmacf100PTxUnicastPktsread-onlymandatoryThe number of good packets transmitted by this port that are directed to a unicast address.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.32Columnsmacf100PTxCollisionsread-onlymandatoryThe number of collisions experienced by this port during packet transmissions.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.33Columnsmacf100PTxSingleCollisionread-onlymandatoryThe number of packets successfully transmitted by this port that experienced exactly one collision.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.34Columnsmacf100PTxMultipleCollisionread-onlymandatoryThe number of packets successfully transmitted by this port that experienced more than one collision.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.35Columnsmacf100PTxDeferredTransmitread-onlymandatoryThe number of packets transmitted by a this port for which the first transmission attempt was delayed because the medium was busy.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.36Columnsmacf100PTxLateCollisionread-onlymandatoryThe number of times that a collision was detected later than 512 bit-times into the transmission of a packet.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.37Columnsmacf100PTxExcessiveCollisionread-onlymandatoryThe number of packets that were not transmitted from this port because 16 unsucessful attempts were made to transmit the packet.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.38Columnsmacf100PTxFrameInDiscread-onlymandatoryThe number of valid packets received which are discarded by the forwarding process due to lack of space on an output queue. This attribute only increments if a…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.39Columnsmacf100PTxPausePktsread-writemandatoryThe number of PAUSE frames transmitted by this port. This implies that the port is in full duplex mode and that 802.3x flow control was enabled at the completi…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.40Columnsmacf100PRxUndersizePktsread-onlymandatoryThe number of good packets received by this port that are less than 64 bytes long (excluding framing bits but including the Frame Check Sequence).
1.3.6.1.4.1.868.2.4.1.2.2.15.1.41Columnsmacf100PRxPausePktsread-writemandatoryThe number of PAUSE frames recieved by this port. The PAUSE frame must have a valid MAC Control Frame EtherType field (88- 08h), have a destination MAC address…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.42Columnsmacf100PPkts64Octetsread-onlymandatoryThe number of packets, including error packets, that are 64 bytes long.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.43Columnsmacf100PPkts65to127Octetsread-onlymandatoryThe number of packets, including error packets, that are between 65 and 127 bytes long.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.44Columnsmacf100PPkts128to255Octetsread-onlymandatoryThe number of packets, including error packets, that are between 128 and 255 bytes long.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.45Columnsmacf100PPkts256to511Octetsread-onlymandatoryThe number of packets, including error packets, that are between 256 and 511 bytes long.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.46Columnsmacf100PPkts512to1023Octetsread-onlymandatoryThe number of packets, including error packets, that are between 512 and 1023 bytes long.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.47Columnsmacf100PPkts1024to1522Octetsread-onlymandatoryThe number of packets, including error packets, that are between 1024 and 1522 bytes long.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.48Columnsmacf100PRxOversizePktsread-onlymandatoryThe number of good packets received by this port that are longer than 1522 bytes inclusive (excluding framing bits but including the Frame Check Sequence). Not…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.49Columnsmacf100PRxJabbersread-onlymandatoryThe number of packets received by a port that are longer than 1522 bytes and have either a Frame Check Sequence error or an alignment error.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.50Columnsmacf100PRxAlignmentErrorsread-onlymandatoryThe number of packets received by this port that have a length (excluding framing bits but including the Frame Check Sequence) between 64 and 1522 bytes inclus…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.51Columnsmacf100PRxFCSErrorsread-onlymandatoryThe number of packets received by this port that have a length (excluding framing bits but including the Frame Check Sequence) between 64 and 1522 bytes inclus…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.52Columnsmacf100PRxGoodOctetsread-onlymandatoryThe total number of bytes in all good packets received by a port (excluding framing bits but including Frame Check Sequences).
1.3.6.1.4.1.868.2.4.1.2.2.15.1.53Columnsmacf100PWrapRxGoodOctetsread-onlymandatoryThe number of times that the unsigned 32-bit smacf100PRxGoodOctets(52) MIB variable for this port has wrapped.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.54Columnsmacf100PRxDropPktsread-onlymandatoryThe number of good packets received by this port that were dropped due to lack of resources (e.g. lack of input buffers) or were dropped due to a lack of resou…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.55Columnsmacf100PRxUnicastPktsread-onlymandatoryThe number of good packets received by this port that are addressed to a unicast address.
1.3.6.1.4.1.868.2.4.1.2.2.15.1.56Columnsmacf100PRxMulticastPktsread-onlymandatoryThe number of good packets received by this port that are directed to a multicast address. This counter includes neither errored multicast packets nor valid br…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.57Columnsmacf100PRxBroadcastPktsread-onlymandatoryThe number of good packets received by this port that are directed to the broadcast address. This counter includes neither errored broadcast packets nor valid …
1.3.6.1.4.1.868.2.4.1.2.2.15.1.58Columnsmacf100PRxSAChangesread-onlymandatoryThe number of times the Source Ethernet Address of good receive packets has changed from the previous value. A count greater than one generally indicates that …
1.3.6.1.4.1.868.2.4.1.2.2.15.1.59Columnsmacf100PRxFragmentsread-onlymandatoryThe number of packets received by a port that are shorter than 64 bytes (excluding framing bits) and have either an Frame Check Sequence error or an alignment …
1.3.6.1.4.1.868.2.4.1.2.2.15.1.60Columnsmacf100PRxExcessSizeDiscread-onlymandatoryThe number of good packets received by this port that are longer than 1536 bytes (excluding framing bits but including Frame Check Sequences) and were discarde…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.61Columnsmacf100PRxSymbolErrorread-onlymandatoryThe total number of times this port received a packet which had a valid length, but contained at least one invalid symbol. The counter only increments once per…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.62Columnsmacf100PQosPriorityread-writemandatoryWhen this variable is set to 'high(1)', this port becomes a high-priority port. This means that all packets received on this port for transission on other port…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.63Columnsmacf100PQosPauseread-writemandatoryWhen the global variable smacf100QosEnable(7) is set to 'enabled(1)', then the port-specific variable smacf100PQosPause(63) controls whether or not the port su…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.64Columnsmacf100PAdvPauseread-writemandatoryEnable/disable control for this advertised autonegotiation mode. When Pause capability is autonegotiated (at the Physical level), the MAC layer may then send P…
1.3.6.1.4.1.868.2.4.1.2.2.15.1.65Columnsmacf100PCacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.16Tablecpsld100Tablenot-accessiblemandatorySparse table containing one entry for each CPSLD100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.16.1Rowcpsld100Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSLD100
1.3.6.1.4.1.868.2.4.1.2.2.16.1.1Columncpsld100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.16.1.2Columncpsld100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.16.1.3Columncpsld100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.16.1.4Columncpsld100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.16.1.5Columncpsld100Ps1Powerread-onlymandatoryPower status, first power supply slot. Value is on(1) when the supply is capable of supplying power.
1.3.6.1.4.1.868.2.4.1.2.2.16.1.6Columncpsld100Ps1InUseread-onlymandatoryPower status, first power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet.
1.3.6.1.4.1.868.2.4.1.2.2.16.1.7Columncpsld100Ps2Powerread-onlymandatoryPower status, second power supply slot. Value is on(1) when the supply is capable of supplying power.
1.3.6.1.4.1.868.2.4.1.2.2.16.1.8Columncpsld100Ps2InUseread-onlymandatoryPower status, second power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet.
1.3.6.1.4.1.868.2.4.1.2.2.17Tablecdftf100Tablenot-accessiblemandatorySparse table containing one entry for each CDFTF100 Dual telco Media Converter in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.17.1Rowcdftf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CDFTF100
1.3.6.1.4.1.868.2.4.1.2.2.17.1.1Columncdftf100SubDeviceIndexread-onlymandatoryGenerally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i…
1.3.6.1.4.1.868.2.4.1.2.2.17.1.2Columncdftf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.17.1.3Columncdftf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.17.1.4Columncdftf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.17.1.5Columncdftf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.17.1.6Columncdftf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.17.1.7Columncdftf100MRevisionread-onlymandatoryThe marketing revision of the device
1.3.6.1.4.1.868.2.4.1.2.2.17.1.8Columncdftf100TPLinkTblread-onlymandatoryThis table contains the link status of each twisted pair port in the CDFTF100. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.17.1.9Columncdftf100FiberLinkTblread-onlymandatoryThis table contains the link status of each fiber port in the CDFTF100. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.17.1.10Columncdftf100TPActivityTblread-onlymandatoryNetowrk traffic indicator for the copper port(s) on this device. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.17.1.11Columncdftf100FiberActivityTblread-onlymandatoryNetowrk traffic indicator for the fiber port(s) on this device. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.17.1.12Columncdftf100ConnectorTblread-onlymandatoryThis table contains the link status of each port of this device. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.17.1.13Columncdftf100FirmwareRevisionread-onlymandatoryThe style of connectors built into each port of this device.
1.3.6.1.4.1.868.2.4.1.2.2.17.1.14Columncdftf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.18Tablecpsvt100Tablenot-accessiblemandatorySparse table containing one entry for each CPSVT100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.18.1Rowcpsvt100Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSVT100
1.3.6.1.4.1.868.2.4.1.2.2.18.1.1Columncpsvt100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.18.1.2Columncpsvt100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.18.1.3Columncpsvt100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.4Columncpsvt100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.5Columncpsvt100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.6Columncpsvt100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.7Columncpsvt100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.8Columncpsvt100CopperLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.9Columncpsvt100Faultread-onlymandatoryValue is yes(1) when either CopperLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.18.1.10Columncpsvt100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.11Columncpsvt100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.12Columncpsvt100TermTimingread-writemandatoryLocal Terminal Timing setting. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends to the DCE. Since this signal can…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.13Columncpsvt100LoopBackread-writemandatoryRemote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.14Columncpsvt100CableModeread-onlymandatoryA description of the type of cable that is attached to the Copper interface of the local device.
1.3.6.1.4.1.868.2.4.1.2.2.18.1.15Columncpsvt100DCEread-onlymandatoryAn indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this status is derived from the type …
1.3.6.1.4.1.868.2.4.1.2.2.18.1.16Columncpsvt100InvertTXread-onlymandatoryLocal transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of t…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.17Columncpsvt100InvertRXread-onlymandatoryLocal receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of th…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.18Columncpsvt100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.19Columncpsvt100FirmwareRevread-onlymandatoryLocal firmware revision.
1.3.6.1.4.1.868.2.4.1.2.2.18.1.20Columncpsvt100RmtDetectedread-onlymandatoryHas the value yes(1) if management communcations have been established with a remote media converter.
1.3.6.1.4.1.868.2.4.1.2.2.18.1.21Columncpsvt100RmtTermTimingread-writemandatoryLocal Terminal Timing setting of the remotely managed CPSVTxxx. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends …
1.3.6.1.4.1.868.2.4.1.2.2.18.1.22Columncpsvt100RmtLoopBackread-writemandatoryRemote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.23Columncpsvt100RmtCableModeread-writemandatoryA description of the type of cable that is attached to the Copper interface of the local device.
1.3.6.1.4.1.868.2.4.1.2.2.18.1.24Columncpsvt100RmtDCEread-writemandatoryAn indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this status is derived from the type …
1.3.6.1.4.1.868.2.4.1.2.2.18.1.25Columncpsvt100RmtInvertTXread-writemandatoryLocal transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of t…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.26Columncpsvt100RmtInvertRXread-writemandatoryLocal receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of th…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.27Columncpsvt100RmtConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.18.1.28Columncpsvt100RmtFirmwareRevread-onlymandatoryLocal firmware revision.
1.3.6.1.4.1.868.2.4.1.2.2.18.1.29Columncpsvt100RmtCopperLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.30Columncpsvt100RmtFiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.18.1.31Columncpsvt100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.19Tablecemtf100Tablenot-accessiblemandatorySparse table containing one entry for each CEMTF100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.19.1Rowcemtf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CEMTF100
1.3.6.1.4.1.868.2.4.1.2.2.19.1.1Columncemtf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.19.1.2Columncemtf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.19.1.3Columncemtf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.19.1.4Columncemtf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.19.1.5Columncemtf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.19.1.6Columncemtf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.19.1.7Columncemtf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.19.1.8Columncemtf100OffHookread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.19.1.9Columncemtf100Faultread-onlymandatoryValue is yes(1) when either OffHook or FiberLink has value of down
1.3.6.1.4.1.868.2.4.1.2.2.19.1.10Columncemtf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.19.1.11Columncemtf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.19.1.12Columncemtf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.20Tablecaptf100Tablenot-accessiblemandatorySparse table containing one entry for each CAPTF100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.20.1Rowcaptf100Entrynot-accessiblemandatoryStatus and configuration entries for a single CAPTF100
1.3.6.1.4.1.868.2.4.1.2.2.20.1.1Columncaptf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.20.1.2Columncaptf100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.20.1.3Columncaptf100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.20.1.4Columncaptf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.20.1.5Columncaptf100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.20.1.6Columncaptf100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.20.1.7Columncaptf100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.20.1.8Columncaptf100InUseread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.20.1.9Columncaptf100Faultread-onlymandatoryValue is yes(1) when either OffHook or FiberLink has value of down
1.3.6.1.4.1.868.2.4.1.2.2.20.1.10Columncaptf100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.20.1.11Columncaptf100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.20.1.12Columncaptf100FirmwareRevread-onlymandatoryThe firmware revision level for this device.
1.3.6.1.4.1.868.2.4.1.2.2.20.1.13Columncaptf100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.20.1.14Columncaptf100Emulatesread-onlymandatoryThis read-only variable indicates the emulation type and configuration of the device. CAPTF100 devices exist in two varieties, the CAPTF10033xx-100, the copper…
1.3.6.1.4.1.868.2.4.1.2.2.21Tablecfetf205Tablenot-accessiblemandatorySparse table containing one entry for each CFTEF205 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s…
1.3.6.1.4.1.868.2.4.1.2.2.21.1Rowcfetf205Entrynot-accessiblemandatoryStatus and configuration entries for a single CFETF205
1.3.6.1.4.1.868.2.4.1.2.2.21.1.1Columncfetf205BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.21.1.2Columncfetf205SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.21.1.3Columncfetf205Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.4Columncfetf205MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.5Columncfetf205CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.6Columncfetf205SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.7Columncfetf205ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.8Columncfetf205ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.9Columncfetf205TPLinkread-onlymandatoryStatus of Twisted Pair Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.10Columncfetf205FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.11Columncfetf205Faultread-onlymandatoryValue is yes(1) when either TPLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.21.1.12Columncfetf205FastLinkPulseread-writemandatoryWhen set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the convert…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.13Columncfetf205Enabledread-writemandatoryWhen this configuration item is set to no(2), the device passes no network traffic.
1.3.6.1.4.1.868.2.4.1.2.2.21.1.14Columncfetf205Pauseread-writemandatoryThe Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.15Columncfetf205LinkPassThroughread-writemandatoryEnable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.16Columncfetf205AutoCrossread-writemandatoryEnable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode.
1.3.6.1.4.1.868.2.4.1.2.2.21.1.17Columncfetf205TPActivityread-onlymandatoryNetwork traffic indicator for Copper side of this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.18Columncfetf205FiberActivityread-onlymandatoryNetwork traffic indicator for Fiber side of this device
1.3.6.1.4.1.868.2.4.1.2.2.21.1.19Columncfetf205ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.20Columncfetf205FarEndFaultread-writemandatoryFar End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal d…
1.3.6.1.4.1.868.2.4.1.2.2.21.1.21Columncfetf205CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.22Tablecbftf150Tablenot-accessiblemandatorySparse table containing one entry for each CBFTF150 switch in the stack. Indexed by sub-device index, cabinet serial number, and slot. Note that some columns o…
1.3.6.1.4.1.868.2.4.1.2.2.22.1Rowcbftf150Entrynot-accessiblemandatoryStatus and configuration entries for a single CBFTF150
1.3.6.1.4.1.868.2.4.1.2.2.22.1.1Columncbftf150SubDeviceIndexread-onlymandatoryGenerally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.2Columncbftf150BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for …
1.3.6.1.4.1.868.2.4.1.2.2.22.1.3Columncbftf150SlotIndexread-onlymandatoryThe slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placehol…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.4Columncbftf150Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.5Columncbftf150MRevisionread-onlymandatoryThe marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.22.1.6Columncbftf150CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.7Columncbftf150SerialNumberread-onlymandatoryThe serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.22.1.8Columncbftf150ConfigModeread-onlymandatoryThis device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.9Columncbftf150FirmwareRevisionread-onlymandatoryThe firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index.
1.3.6.1.4.1.868.2.4.1.2.2.22.1.10Columncbftf150FormFactorread-onlymandatoryA code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number of physical connectors present…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.11Columncbftf150AutoNegotTblread-writemandatoryEnables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are multiple subdevices in this table, …
1.3.6.1.4.1.868.2.4.1.2.2.22.1.12Columncbftf150FullDuplexTblread-writemandatoryIn most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports wit…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.13Columncbftf150100MbpsTblread-writemandatoryIn most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, this is a status indication sho…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.14Columncbftf150CrossTblread-writemandatoryConfiguration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs if necessary. If autonegotiat…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.15Columncbftf150FarEndFaultTblread-writemandatoryWhen Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform the device at the far end of the…
1.3.6.1.4.1.868.2.4.1.2.2.22.1.16Columncbftf150ConnectorTblread-onlymandatoryThe style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.22.1.17Columncbftf150LinkTblread-onlymandatoryThis table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry per port.
1.3.6.1.4.1.868.2.4.1.2.2.22.1.18Columncbftf150PortCountread-onlymandatoryA count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch.
1.3.6.1.4.1.868.2.4.1.2.2.22.1.19Columncbftf150CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.23Tablecgfeb100Tablenot-accessiblemandatorySparse table containing one entry for each CGFEB100 10/100/1000 Ethernet to Fiber converter in the stack. Indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.23.1Rowcgfeb100Entrynot-accessiblemandatoryStatus and configuration entries for a single CGFEB100
1.3.6.1.4.1.868.2.4.1.2.2.23.1.1Columncgfeb100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.2Columncgfeb100SlotIndexread-onlymandatoryThe slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.3Columncgfeb100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.4Columncgfeb100MRevisionread-onlymandatoryThe marketing revision of this device.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.5Columncgfeb100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.6Columncgfeb100SerialNumberread-onlymandatoryThe serial number of this device.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.7Columncgfeb100ConfigModeread-onlymandatoryThis device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.8Columncgfeb100FirmwareRevisionread-onlymandatoryThe firmware revision level for this device.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.9Columncgfeb100SelfTestFailedread-onlymandatoryThis variable indicates the status of the pass/fail power on test. If the power on test fails, normal operation of this device is probably not possible.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.10Columncgfeb100MonitorTyperead-onlymandatorySome versions of this device support the monitoring of network traffic passing through the converter's fiber interface via a dedicated monitoring port to which…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.11Columncgfeb100LinkPassThroughread-writemandatoryThis configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be p…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.12Columncgfeb100QosEnabledread-writemandatoryThis variable allows Quality of Service functions to be enabled or disabled. This includes the processing of 802.1p tags (See cgfeb100QosHPThreshold(13), cgfeb…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.13Columncgfeb100QosHPThresholdread-writemandatoryWhen an incoming 802.1p priority tag value is greater than or equal to this value (from 0 to 7), the incoming packet will be classified as high-priority. Ignor…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.14Columncgfeb100QosLqWeightread-writemandatoryA value between 1 and 15 indicating the number of packets that should be processed from the low-priority queue before attention is turned to the high-priority …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.15Columncgfeb100QosHqWeightread-writemandatoryA value between 1 and 15 indicating the number of packets that should be processed from the high-priority queue before attention is turned to the low-priority …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.16Columncgfeb100ConnAread-onlymandatoryThe style of copper connector built into this device.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.17Columncgfeb100TPLinkread-onlymandatoryTwisted Pair link status.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.18Columncgfeb100TPSpeedCfgread-writemandatoryThe desired speed of the Twisted Pair interface. This speed can be set to 10Mbps(1) or 100Mbps(2). Operation at 1000Mbps requires autonegotiation. When cgfeb10…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.19Columncgfeb100TPSpeedStatread-onlymandatoryThe actual speed of the Twisted Pair interface: 10Mbps(1), 100Mbps(2), or 1000Mbps(3). If cgfeb100TpAutonegot(24) has the value enabled(1) and cgfeb100TpLink(1…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.20Columncgfeb100TPFullDuplexCfgread-writemandatoryThe desired duplex setting of the Twisted Pair interface. This can be set to fdx(1) (full duplex) or hdx(2) (half duplex). When cgfeb100TpAutonegot(24) has the…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.21Columncgfeb100TPFullDuplexStatread-onlymandatoryThe actual duplex behavior of the Twisted Pair interface. If cgfeb100TpAutonegot(24) has the value enabled(1) and cgfeb100TpLink(17) has the value down(2), thi…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.22Columncgfeb100TPCrossCfgread-writemandatoryThe desired TX/RX Pair orientation of the Twisted Pair interface. This can be set to mdi(1) (straight through), mdix(2) (crossed over), or auto(3). When cgfeb1…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.23Columncgfeb100TPCrossStatread-onlymandatoryThe actual TX/RX Pair orientation of the Twisted Pair interface, usually mdi(1) (straight through) or mdix(2) (crossed over). When the device does not know the…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.24Columncgfeb100TPAutoNegotread-writemandatoryEnables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.25Columncgfeb100TPAdv10HDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.26Columncgfeb100TPAdv10FDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.27Columncgfeb100TPAdv100HDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.28Columncgfeb100TPAdv100FDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.29Columncgfeb100TPAdv1000HDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.30Columncgfeb100TPAdv1000FDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.31Columncgfeb100TPLpAdvPauseread-onlymandatoryThis read-only variable shows the pause capability advertised by the twisted pair port's link partner. Values 1 through 4 for this variable are the same as tho…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.32Columncgfeb100TPLpAdv10HDXread-writemandatoryThis read-only variable shows twisted pair port's link partner's willingness to connect at 10Mbps Half Duplex. If the device does not support the reporting of …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.33Columncgfeb100TPLpAdv10FDXread-onlymandatoryThis read-only variable shows twisted pair port's link partner's willingness to connect at 10Mbps Full Duplex. If the device does not support the reporting of …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.34Columncgfeb100TPLpAdv100HDXread-onlymandatoryThis read-only variable shows twisted pair port's link partner's willingness to connect at 100Mbps Half Duplex. If the device does not support the reporting of…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.35Columncgfeb100TPLpAdv100FDXread-onlymandatoryThis read-only variable shows twisted pair port's link partner's willingness to connect at 100Mbps Full Duplex. If the device does not support the reporting of…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.36Columncgfeb100TPLpAdv1000HDXread-onlymandatoryThis read-only variable shows twisted pair port's link partner's willingness to connect at 1000Mbps Half Duplex. If the device does not support the reporting o…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.37Columncgfeb100TPLpAdv1000FDXread-onlymandatoryThis read-only variable shows twisted pair port's link partner's willingness to connect at 1000Mbps Full Duplex. If the device does not support the reporting o…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.38Columncgfeb100TPAdvPauseread-writemandatoryEnable/disable control for autonegotiation advertising of Twisted Pair Pause capability. Selectable values are symmetric(1), asymRX(2) (asymmetric, pause frame…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.39Columncgfeb100TPQosPauseread-writemandatoryThis variable allows Twisted Pair Quality Of Service Pause to be enabled or disabled. When cgfeb100QosEnabled(12) is set to enabled(1) and this variable is set…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.40Columncgfeb100TPSacCfgread-writemandatoryThis variable allows Source Address Change traps to be enabled or disabled. If enabled, 'Error' traps will be sent as frequently one per polling cycle any time…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.41Columncgfeb100TPSacStatread-onlymandatoryThis read-only variable has the value changed(1) if the Ethernet source address received on the Twisted Pair interface changed since the device's previous repo…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.42Columncgfeb100ConnBread-onlymandatoryThe style of Fiber connector built into this device.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.43Columncgfeb100FiberLinkread-onlymandatoryThe Fiber Link status for this device.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.44Columncgfeb100FiberFullDuplexCfgread-writemandatoryThe desired duplex setting of the Fiber interface. This can be set to fdx(1) (full duplex) or hdx(2) (half duplex). When cgfeb100TpAutonegot(24) has the value …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.45Columncgfeb100FiberFullDuplexStatread-onlymandatoryThe actual duplex behavior of the Fiber interface: fdx(1) (full duplex) or hdx(2) (half duplex). If cgfeb100FiberAutonegot(46) has the value disabled(2) and th…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.46Columncgfeb100FiberAutoNegotread-writemandatoryAutonegotiation configuration. Fiber autonegotiation is limited to the duplex setting. The fiber's speed is fixed at 1000Mbps.
1.3.6.1.4.1.868.2.4.1.2.2.23.1.47Columncgfeb100FiberAdv1000HDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.48Columncgfeb100FiberAdv1000FDXread-writemandatoryEnable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.49Columncgfeb100FiberLpAdv1000HDXread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 1000Mbps, half duplex. This setting is not supported on fiber…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.50Columncgfeb100FiberLpAdv1000FDXread-writemandatoryThis configuration setting controls whether or not each port advertises willingness to connect at 1000Mbps, full duplex. This setting is not supported on fiber…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.51Columncgfeb100FiberLpAdvPauseread-onlymandatoryThis read-only variable shows the pause capability advertised by the fiber port's link partner. Values 1 through 4 for this variable are the same as those for …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.52Columncgfeb100FiberAdvPauseread-writemandatoryEnable/disable control for autonegotiation advertising of Fiber Pause capability. Selectable values are symmetric(1), asymRX(2) (asymmetric, pause frames flow …
1.3.6.1.4.1.868.2.4.1.2.2.23.1.53Columncgfeb100FiberQosPauseread-writemandatoryThis variable allows Fiber Quality Of Service Pause to be enabled or disabled. When cgfeb100QosEnabled(12) is set to enabled(1) and this variable is set to dis…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.54Columncgfeb100FiberSacCfgread-writemandatoryThis variable allows Source Address Change traps to be enabled or disabled. If enabled, 'Error' traps will be sent as frequently one per polling cycle any time…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.55Columncgfeb100FiberSacStatread-writemandatoryThis read-only variable has the value changed(1) if the Ethernet source address received on the fiber interface changed since the device's previous report to t…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.56Columncgfeb100MonitorTapread-writemandatoryBefore reading this description, see cgfeb100MonitorType(10). This variable controls which side of the fiber port (transmit(1) or receive(2)) is monitored by t…
1.3.6.1.4.1.868.2.4.1.2.2.23.1.57Columncgfeb100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.24Tablecrmfe100Tablenot-accessiblemandatorySparse table containing one entry for each CRMFE100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.24.1Rowcrmfe100Entrynot-accessiblemandatoryStatus and configuration entries for a single CRMFE100
1.3.6.1.4.1.868.2.4.1.2.2.24.1.1Columncrmfe100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.24.1.2Columncrmfe100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.24.1.3Columncrmfe100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.4Columncrmfe100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.5Columncrmfe100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.6Columncrmfe100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.7Columncrmfe100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.8Columncrmfe100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.9Columncrmfe100TPLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.10Columncrmfe100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.11Columncrmfe100Faultread-onlymandatoryValue is yes(1) when either CopperLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.24.1.12Columncrmfe100Autonegotread-writemandatoryAutonegotiation configuration for this device.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.13Columncrmfe100Enabledread-writemandatoryWhen the Enabled configuration item is set to no(2), the converter passes no network traffic in either direction.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.14Columncrmfe100Pauseread-writemandatoryThe Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.15Columncrmfe100LinkPassThroughread-writemandatoryThis configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be p…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.16Columncrmfe100AutoCrossread-writemandatoryOn certain devices, it is possible for hardware to automatically correct errors in cable selection, making the distinction between a 'straight through' cable a…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.17Columncrmfe100TPActivityread-onlymandatoryTwisted Pair Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be n…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.18Columncrmfe100FiberActivityread-onlymandatoryFiber Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notAppli…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.19Columncrmfe100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.20Columncrmfe100FarEndFaultread-writemandatoryFar End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal d…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.21Columncrmfe100NetworkModeread-onlymandatoryRead-only indicator for High Speed Token Ring jumper configuration. If the variable reads tokenRing(1), then the converter is jumpered for High Speed Token Rin…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.22Columncrmfe100UpTimeread-writemandatoryTime since the last reboot in Time Ticks (hundredths of seconds). If the value 0 is written to this variable, the timer is reset. No other write value is accep…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.23Columncrmfe100FirmwareRevisionread-onlymandatoryFirmware revision level of this CRMFE100.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.24Columncrmfe100RmtDetectedread-onlymandatoryHas the value yes(1) if management communcations have been established with a remote media converter.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.25Columncrmfe100RmtTPLinkread-onlymandatoryStatus of Copper Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.26Columncrmfe100RmtFiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.24.1.27Columncrmfe100RmtFaultread-onlymandatoryValue is yes(1) when either TPLink or FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.24.1.28Columncrmfe100RmtAutonegotread-writemandatoryAutonegotiation configuration for this device.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.29Columncrmfe100RmtPauseread-writemandatoryThe Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.30Columncrmfe100RmtLinkPassThroughread-writemandatoryThis configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be p…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.31Columncrmfe100RmtAutoCrossread-writemandatoryOn certain devices, it is possible for hardware to automatically correct errors in cable selection, making the distinction between a 'straight through' cable a…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.32Columncrmfe100RmtTPActivityread-onlymandatoryTwisted Pair Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be n…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.33Columncrmfe100RmtFiberActivityread-onlymandatoryFiber Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notAppli…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.34Columncrmfe100RmtConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.35Columncrmfe100RmtFarEndFaultread-writemandatoryFar End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal d…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.36Columncrmfe100RmtLoopbackread-writemandatoryWhen Remote Loopback is enabled, all packets sent out from the local fiber interface are reflected back by the remote converter rather than being passed out th…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.37Columncrmfe100RmtNetworkModeread-onlymandatoryRead-only indicator for High Speed Token Ring jumper configuration. If the variable reads tokenRing(1), then the converter is jumpered for High Speed Token Rin…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.38Columncrmfe100RmtUpTimeread-writemandatoryTime since the last reboot in Time Ticks (hundredths of seconds). If the value 0 is written to this variable, the timer is reset. No other write value is accep…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.39Columncrmfe100TxFxBwaread-writemandatoryThis variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the ne…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.40Columncrmfe100FxTxBwaread-writemandatoryThis variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the ne…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.41Columncrmfe100TxBytesHread-writemandatoryThese variables measure the traffic (in Bytes) received by the two interfaces of the converter (and therefore transmitted by the opposite interface). 'Tx' refe…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.42Columncrmfe100TxBytesLread-writemandatorySee the DESCRIPTION for cfmfe100TxBytesH(42) above.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.43Columncrmfe100FxBytesHread-writemandatorySee the DESCRIPTION for cfmfe100TxBytesH(42) above.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.44Columncrmfe100FxBytesLread-writemandatorySee the DESCRIPTION for cfmfe100TxBytesH(42) above.
1.3.6.1.4.1.868.2.4.1.2.2.24.1.45Columncrmfe100MscRxBytesread-writemandatoryThis variable measures the traffic (in Bytes) received and transmitted by the Management Subchannel within the Fiber interface. 'Management Subchannel' refers …
1.3.6.1.4.1.868.2.4.1.2.2.24.1.46Columncrmfe100MscTxBytesread-writemandatoryThis variable measures the traffic (in Bytes) received and transmitted by the Management Subchannel within the Fiber interface. 'Management Subchannel' refers …
1.3.6.1.4.1.868.2.4.1.2.2.24.1.47Columncrmfe100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.48Columncrmfe100MbTxFxBwaread-writemandatoryThis variable allows the control of bandwidth allocation. The value of this variable is entered in Megabits per Second, and is automatically rounded to the nea…
1.3.6.1.4.1.868.2.4.1.2.2.24.1.49Columncrmfe100MbFxTxBwaread-writemandatoryThis variable allows the control of bandwidth allocation. The value of this variable is entered in Megabits per Second, and is automatically rounded to the nea…
1.3.6.1.4.1.868.2.4.1.2.2.25Tablecrs2f100Tablenot-accessiblemandatorySparse table containing one entry for each CRS2F100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.25.1Rowcrs2f100Entrynot-accessiblemandatoryStatus and configuration entries for a single CRS2F100
1.3.6.1.4.1.868.2.4.1.2.2.25.1.1Columncrs2f100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.25.1.2Columncrs2f100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.25.1.3Columncrs2f100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.4Columncrs2f100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.25.1.5Columncrs2f100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.6Columncrs2f100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.25.1.7Columncrs2f100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.25.1.8Columncrs2f100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.25.1.9Columncrs2f100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.25.1.10Columncrs2f100Faultread-onlymandatoryValue is yes(1) when FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.25.1.11Columncrs2f100FirmwareRevisionread-onlymandatoryThe Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can discover the revisions on these…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.12Columncrs2f100Loopbackread-writemandatoryLoopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflecte…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.13Columncrs2f100DCEread-onlymandatoryAn indication of whether this device is attached to a DCE (a modem) or a DTE (a terminal or computer).
1.3.6.1.4.1.868.2.4.1.2.2.25.1.14Columncrs2f100CopperActivityread-onlymandatoryThe activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise.
1.3.6.1.4.1.868.2.4.1.2.2.25.1.15Columncrs2f100ConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.16Columncrs2f100RmtDetectedread-onlymandatoryHas the value yes(1) if management communcations have been established with a remote media device.
1.3.6.1.4.1.868.2.4.1.2.2.25.1.17Columncrs2f100RmtLoopbackread-writemandatoryLoopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflecte…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.18Columncrs2f100RmtDCEread-onlymandatoryThis variable describes the status of a remotely managed device. This is an indicator of whether this device is attached to a DCE (a modem) or a DTE (a termina…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.19Columncrs2f100RmtCopperActivityread-onlymandatoryThe activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise. When n…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.20Columncrs2f100RmtConfigModeread-onlymandatoryThis device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config…
1.3.6.1.4.1.868.2.4.1.2.2.25.1.21Columncrs2f100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.26Tablecrs4f100Tablenot-accessiblemandatorySparse table containing one entry for each CRS4F100 in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.1.2.2.26.1Rowcrs4f100Entrynot-accessiblemandatoryStatus and configuration entries for a single CRS4F100
1.3.6.1.4.1.868.2.4.1.2.2.26.1.1Columncrs4f100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.26.1.2Columncrs4f100SlotIndexread-onlymandatoryThe slot in which the device is installed
1.3.6.1.4.1.868.2.4.1.2.2.26.1.3Columncrs4f100Groupsread-writemandatoryUser-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent…
1.3.6.1.4.1.868.2.4.1.2.2.26.1.4Columncrs4f100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.1.2.2.26.1.5Columncrs4f100CfgMatchread-onlymandatoryyes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i…
1.3.6.1.4.1.868.2.4.1.2.2.26.1.6Columncrs4f100SerialNumberread-onlymandatoryThe serial number of this device
1.3.6.1.4.1.868.2.4.1.2.2.26.1.7Columncrs4f100ConnAread-onlymandatoryThe style of Fiber connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.26.1.8Columncrs4f100ConnBread-onlymandatoryThe style of Copper connector built into this device
1.3.6.1.4.1.868.2.4.1.2.2.26.1.9Columncrs4f100FiberLinkread-onlymandatoryStatus of Fiber Link for this device
1.3.6.1.4.1.868.2.4.1.2.2.26.1.10Columncrs4f100Faultread-onlymandatoryValue is yes(1) when FiberLink has value linkDown(2)
1.3.6.1.4.1.868.2.4.1.2.2.26.1.11Columncrs4f100FirmwareRevisionread-onlymandatoryThe Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can discover the revisions on these…
1.3.6.1.4.1.868.2.4.1.2.2.26.1.12Columncrs4f100CopperActivityread-onlymandatoryThe activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise.
1.3.6.1.4.1.868.2.4.1.2.2.26.1.13Columncrs4f100CacheCleanread-onlymandatoryWhen the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)…
1.3.6.1.4.1.868.2.4.1.2.2.27Tablecmefg100Tablenot-accessiblemandatoryGenerated CMEFG100 MIB Version 041110a
1.3.6.1.4.1.868.2.4.1.2.2.27.1Rowcmefg100Entrynot-accessiblemandatoryStatus and configuration entries for a single CMEFG100
1.3.6.1.4.1.868.2.4.1.2.2.27.1.1Columncmefg100SubDeviceIndexread-onlymandatoryIf the name of a particular MIB variable does not end in 'Tbl', then it uses the placeholder value '1' in the subdevice index column.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.2Columncmefg100BiaIndexread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.3Columncmefg100SlotIndexread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.4Columncmefg100Groupsread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.5Columncmefg100MRevisionread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.6Columncmefg100CfgMatchread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.7Columncmefg100ImcLocEnableread-writemandatoryEnable periodic upload of local Interface MIB Counters from CMEFG100 to Agent. cmefg100ImcxxxTbl subdevice 1=local tp, subdevice 2=local fiber.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.8Columncmefg100ImcLocResetread-writemandatoryset to reset(1) to clear all local cmefg100Imc counters.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.9Columncmefg100ImcRmtEnableread-writemandatoryEnable periodic upload of remote Interface MIB Counters from CMEFG100 to Agent. cmefg100ImcxxxTbl subdevice 3=remote tp, subdevice 4=remote fiber.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.10Columncmefg100ImcRmtResetread-writemandatoryset to reset(1) to clear all remote cmefg100Imc counters.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.11Columncmefg100ImcRxAlignmentErrorsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.12Columncmefg100ImcRxBroadcastPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.13Columncmefg100ImcRxDropPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.14Columncmefg100ImcRxExcessSizeDiscTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.15Columncmefg100ImcRxFCSErrorsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.16Columncmefg100ImcRxFragmentsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.17Columncmefg100ImcRxGoodOctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.18Columncmefg100ImcRxGoodOctetsWrapTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.19Columncmefg100ImcRxJabbersTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.20Columncmefg100ImcRxMulticastPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.21Columncmefg100ImcRxOctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.22Columncmefg100ImcRxOctetsWrapTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.23Columncmefg100ImcRxOversizePktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.24Columncmefg100ImcRxPausePktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.25Columncmefg100ImcRxPkts1024to1522OctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.26Columncmefg100ImcRxPkts128to255OctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.27Columncmefg100ImcRxPkts256to511OctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.28Columncmefg100ImcRxPkts512to1023OctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.29Columncmefg100ImcRxPkts64OctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.30Columncmefg100ImcRxPkts65to127OctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.31Columncmefg100ImcRxQosOctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.32Columncmefg100ImcRxQosOctetsWrapTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.33Columncmefg100ImcRxQosPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.34Columncmefg100ImcRxSAChangesTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.35Columncmefg100ImcRxSymbolErrorTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.36Columncmefg100ImcRxUndersizePktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.37Columncmefg100ImcRxUnicastPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.38Columncmefg100ImcTxBroadcastPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.39Columncmefg100ImcTxCollisionsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.40Columncmefg100ImcTxDeferredTransmitTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.41Columncmefg100ImcTxDropPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.42Columncmefg100ImcTxExcessiveCollisionTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.43Columncmefg100ImcTxFrameInDiscTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.44Columncmefg100ImcTxLateCollisionTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.45Columncmefg100ImcTxMulticastPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.46Columncmefg100ImcTxMultipleCollisionTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.47Columncmefg100ImcTxOctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.48Columncmefg100ImcTxOctetsWrapTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.49Columncmefg100ImcTxPausePktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.50Columncmefg100ImcTxQosOctetsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.51Columncmefg100ImcTxQosOctetsWrapTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.52Columncmefg100ImcTxQosPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.53Columncmefg100ImcTxSingleCollisionTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.54Columncmefg100ImcTxUnicastPktsTblread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.55Columncmefg100LadCacheCmdread-writemandatoryAll variables starting with cmefg100Lad relate to the Learned MAC Address Database. Due to the large size of the LAD database and the limited memory within the…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.56Columncmefg100LadCacheStateread-writemandatoryThis variable shows the current state of the Agent's cache buffer with respect to the Learned Address Database. A value of 'ready' means that the cache buffer …
1.3.6.1.4.1.868.2.4.1.2.2.27.1.57Columncmefg100LadEditCmdread-writemandatorySetting this var to 'write' causes LadEditMac, LadEditPort, and LadEditVid to be written (insert/overwrite as required) to the LAD. Setting this var to 'delete…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.58Columncmefg100LadEditMacread-writemandatoryA plain-text representation of a MAC address to be used the next time cmefg100LadEditCmd is set to write or delete.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.59Columncmefg100LadEditPortread-writemandatoryA port to be used the next time cmefg100LadEditCmd is set to write.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.60Columncmefg100LadEditVidread-writemandatoryA VLAN Id to be used the next time cmefg100LadEditCmd is set to write. Not valid when cmefg100VlanEnable is disabled(2)
1.3.6.1.4.1.868.2.4.1.2.2.27.1.61Columncmefg100LadEntriesread-onlymandatoryA count of the number of entries currently in the LAD Cache. See also cmefg100LadCacheState. If a LAD cache-filling transfer is in progress, this variable can …
1.3.6.1.4.1.868.2.4.1.2.2.27.1.62Columncmefg100LadMacTblread-onlymandatoryAn Ethernet MAC address in the LAD table. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.63Columncmefg100LadPortTblread-onlymandatoryA port in the LAD table. Drop means 'forward to neither port' The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.64Columncmefg100LadStaticTblread-onlymandatoryAn indication of whether the indexed entry in the LAD is static or dynamic. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEnt…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.65Columncmefg100LadVidTblread-onlymandatoryA VLAN Id in the LAD table. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (either because…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.66Columncmefg100LocColdstartread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.67Columncmefg100LocDmiRxPowerread-onlymandatoryDMI: Diagnostic Monitoring Interface for fiber transceivers
1.3.6.1.4.1.868.2.4.1.2.2.27.1.68Columncmefg100LocDmiRxPowerAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.69Columncmefg100LocDmiTempread-onlymandatoryIn tenths of degrees C
1.3.6.1.4.1.868.2.4.1.2.2.27.1.70Columncmefg100LocDmiTempAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.71Columncmefg100LocDmiTxBiasAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.72Columncmefg100LocDmiTxBiasCurrentread-onlymandatoryIn microamperes
1.3.6.1.4.1.868.2.4.1.2.2.27.1.73Columncmefg100LocDmiTxPowerread-onlymandatoryIn microwatts
1.3.6.1.4.1.868.2.4.1.2.2.27.1.74Columncmefg100LocDmiTxPowerAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.75Columncmefg100LocFiberAdv1000FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.76Columncmefg100LocFiberAdv1000HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.77Columncmefg100LocFiberAutoNegotread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.78Columncmefg100LocFiberConnAread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.79Columncmefg100LocFiberDuplexread-writemandatoryRead-only values 3..5 are returned when autonegotiation is enabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.80Columncmefg100LocFiberLinkread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.81Columncmefg100LocFiberPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.82Columncmefg100LocFiberQosPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.83Columncmefg100LocFiberSacEnableread-writemandatoryEnable/disable traps for Source Address Change
1.3.6.1.4.1.868.2.4.1.2.2.27.1.84Columncmefg100LocFiberSacStatusread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.85Columncmefg100LocFirmwareRevisionread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.86Columncmefg100LocFpgaRevread-onlymandatoryField-Programmable Gate Array revision
1.3.6.1.4.1.868.2.4.1.2.2.27.1.87Columncmefg100LocFxTxBwaKbread-writemandatoryFX to TX bandwidth allocation, in Kbps
1.3.6.1.4.1.868.2.4.1.2.2.27.1.88Columncmefg100LocFxTxBwaMbread-writemandatoryFX to TX bandwidth allocation, in Mbps
1.3.6.1.4.1.868.2.4.1.2.2.27.1.89Columncmefg100LocOamActiveModeread-onlymandatoryOAM: Operation, Administration, and Maintenance
1.3.6.1.4.1.868.2.4.1.2.2.27.1.90Columncmefg100LocOamAdminControlread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.91Columncmefg100LocOamConfigRevisionread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.92Columncmefg100LocOamControlInUnknownOpcodesread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.93Columncmefg100LocOamCriticalEventread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.94Columncmefg100LocOamDuplicateEventNotificationRxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.95Columncmefg100LocOamFramesLostDueToOamErrorread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.96Columncmefg100LocOamInformationRxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.97Columncmefg100LocOamInformationTxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.98Columncmefg100LocOamLastGaspread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.99Columncmefg100LocOamLinkEventsread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.100Columncmefg100LocOamLinkFaultread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.101Columncmefg100LocOamLocDteDiscread-onlymandatorydiscovery state
1.3.6.1.4.1.868.2.4.1.2.2.27.1.102Columncmefg100LocOamLoopbackControlRxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.103Columncmefg100LocOamLoopbackControlTxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.104Columncmefg100LocOamMacAddressread-onlymandatoryThe MAC address of the OAM entity.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.105Columncmefg100LocOamMaxOamPduSizeread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.106Columncmefg100LocOamMultiplexorStateread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.107Columncmefg100LocOamOperStatusread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.108Columncmefg100LocOamOrgSpecificRxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.109Columncmefg100LocOamOrgSpecificTxread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.110Columncmefg100LocOamParserStateread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.111Columncmefg100LocOamRmtDteDiscread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.112Columncmefg100LocOamRmtLoopbackread-onlymandatoryIndicates whether or not local has support to allow remote to initiate remote loopback mode.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.113Columncmefg100LocOamUnidirectionalread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.114Columncmefg100LocOamVarRetrievalread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.115Columncmefg100LocSelfTestFailedread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.116Columncmefg100LocSerialNumberread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.117Columncmefg100LocTpAdv1000FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.118Columncmefg100LocTpAdv1000HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.119Columncmefg100LocTpAdv100FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.120Columncmefg100LocTpAdv100HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.121Columncmefg100LocTpAdv10FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.122Columncmefg100LocTpAdv10HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.123Columncmefg100LocTpAutoNegotread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.124Columncmefg100LocTpConnBread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.125Columncmefg100LocTpCrossread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.126Columncmefg100LocTpDuplexread-writemandatoryRead-only values 3..5 are returned when autonegotiation is enabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.127Columncmefg100LocTpLinkread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.128Columncmefg100LocTpPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.129Columncmefg100LocTpQosPauseread-writemandatoryQOS: Quality of Service
1.3.6.1.4.1.868.2.4.1.2.2.27.1.130Columncmefg100LocTpSacEnableread-writemandatoryEnable/disable traps for Source Address Change
1.3.6.1.4.1.868.2.4.1.2.2.27.1.131Columncmefg100LocTpSacStatusread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.132Columncmefg100LocTpSpeedread-writemandatoryRead-only values 3..6 are returned when autonegotiation is enabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.133Columncmefg100LocTxFxBwaKbread-writemandatoryTX to FX bandwidth allocation, in Kbps
1.3.6.1.4.1.868.2.4.1.2.2.27.1.134Columncmefg100LocTxFxBwaMbread-writemandatoryTX to FX bandwidth allocation, in Mbps
1.3.6.1.4.1.868.2.4.1.2.2.27.1.135Columncmefg100LocUptimeread-writemandatoryWrite with 0 to reset.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.136Columncmefg100QosHqWeightread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.137Columncmefg100QosLqWeightread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.138Columncmefg100QosPriorityread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.139Columncmefg100RmtColdStartread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.140Columncmefg100RmtDetectedread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.141Columncmefg100RmtDmiRxPowerread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.142Columncmefg100RmtDmiRxPowerAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.143Columncmefg100RmtDmiTempread-onlymandatoryIn tenths of degrees C
1.3.6.1.4.1.868.2.4.1.2.2.27.1.144Columncmefg100RmtDmiTempAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.145Columncmefg100RmtDmiTxBiasAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.146Columncmefg100RmtDmiTxBiasCurrentread-onlymandatoryIn microamperes
1.3.6.1.4.1.868.2.4.1.2.2.27.1.147Columncmefg100RmtDmiTxPowerread-onlymandatoryIn microwatts
1.3.6.1.4.1.868.2.4.1.2.2.27.1.148Columncmefg100RmtDmiTxPowerAlarmread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.149Columncmefg100RmtFactoryResetread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.150Columncmefg100RmtFiberAutoNegotread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.151Columncmefg100RmtFiberLinkread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.152Columncmefg100RmtFiberPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.153Columncmefg100RmtFiberQosPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.154Columncmefg100RmtFirmwareRevisionread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.155Columncmefg100RmtFpgaRevread-onlymandatoryField-Programmable Gate Array revision
1.3.6.1.4.1.868.2.4.1.2.2.27.1.156Columncmefg100RmtOamActiveModeread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.157Columncmefg100RmtOamCriticalEventread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.158Columncmefg100RmtOamLastGaspread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.159Columncmefg100RmtOamLinkEventsread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.160Columncmefg100RmtOamLinkFaultread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.161Columncmefg100RmtOamLocDteDiscread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.162Columncmefg100RmtOamPeerConfigRevisionread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.163Columncmefg100RmtOamPeerMacAddressread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.164Columncmefg100RmtOamPeerMaxOamPduSizeread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.165Columncmefg100RmtOamPeerMultiplexorStateread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.166Columncmefg100RmtOamPeerParserStateread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.167Columncmefg100RmtOamPeerVendorInforead-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.168Columncmefg100RmtOamPeerVendorOuiread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.169Columncmefg100RmtOamRmtDteDiscread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.170Columncmefg100RmtOamRmtLoopbackread-writemandatoryInitiates remote loopback mode if the remote supports it. See RmtOamPeerParserState for status information
1.3.6.1.4.1.868.2.4.1.2.2.27.1.171Columncmefg100RmtOamUnidirectionalread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.172Columncmefg100RmtOamVarRetrievalread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.173Columncmefg100RmtSelfTestFailedread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.174Columncmefg100RmtSerialNumberread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.175Columncmefg100RmtTpAdv1000FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.176Columncmefg100RmtTpAdv1000HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.177Columncmefg100RmtTpAdv100FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.178Columncmefg100RmtTpAdv100HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.179Columncmefg100RmtTpAdv10FDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.180Columncmefg100RmtTpAdv10HDXread-writemandatoryRead-only value notApplicable returned when autonegotiation is disabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.181Columncmefg100RmtTpAutoNegotread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.182Columncmefg100RmtTpCrossread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.183Columncmefg100RmtTpDuplexread-writemandatoryRead-only values 3..5 are returned when autonegotiation is enabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.184Columncmefg100RmtTpLinkread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.185Columncmefg100RmtTpPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.186Columncmefg100RmtTpQosPauseread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.187Columncmefg100RmtTpSpeedread-writemandatoryRead-only values 3..6 are returned when autonegotiation is enabled
1.3.6.1.4.1.868.2.4.1.2.2.27.1.188Columncmefg100RmtUptimeread-writemandatoryWrite with 0 to reset.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.189Columncmefg100VlanCacheCmdread-writemandatoryAll variables starting with cmefg100Lad relate to 802.1Q VLAN controls. Setting this var to loadCache commands the agent to upload the VLAN table from the devi…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.190Columncmefg100VlanCacheStateread-writemandatoryThe agent discards the VLAN table shortly after uploading it to prevent the reporting of outdated information. This variable shows the current state of the cac…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.191Columncmefg100VlanEditCmdread-writemandatorySetting this var to write causes VlanEditFwdFiber, VlanEditFwdTp, VlanEditUntagFiber, VlanEditUntagTp, and VlanEditVid to be written to the VLAN tablei (i.e. i…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.192Columncmefg100VlanEditFwdFiberread-onlymandatoryA fiber egress rule to be acted upon by VlanEditCmd
1.3.6.1.4.1.868.2.4.1.2.2.27.1.193Columncmefg100VlanEditFwdTpread-onlymandatoryA twisted pair egress rule to be acted upon by VlanEditCmd
1.3.6.1.4.1.868.2.4.1.2.2.27.1.194Columncmefg100VlanEditUntagFiberread-onlymandatoryA fiber untag rule to be acted upon by VlanEditCmd
1.3.6.1.4.1.868.2.4.1.2.2.27.1.195Columncmefg100VlanEditUntagTpread-onlymandatoryA twisted pair untag rule to be acted upon by VlanEditCmd
1.3.6.1.4.1.868.2.4.1.2.2.27.1.196Columncmefg100VlanEditVidread-writemandatoryA VLAN Id to be acted upon by VlanEditCmd
1.3.6.1.4.1.868.2.4.1.2.2.27.1.197Columncmefg100VlanEnableread-writemandatoryEnable/disable for 802.1Q VLAN tag processing.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.198Columncmefg100VlanEntriesread-onlymandatoryA count of the number of entries currently in the VLAN table cache. See also VlanCacheState. If a VLAN cache-filling transfer is in progress, this variable can…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.199Columncmefg100VlanFiberDefaultPriread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.200Columncmefg100VlanFiberDefaultVidread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.201Columncmefg100VlanFiberInUntaggedDropread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.202Columncmefg100VlanFwdFiberTblread-onlymandatoryIndicates whether packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) are forwarded or…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.203Columncmefg100VlanFwdTpTblread-onlymandatoryIndicates whether packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) are forwarded or…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.204Columncmefg100VlanIngressVidHitNoMemread-writemandatoryIngress violation - port from which frame originates is not a member of the VLAN indicated by the frame's tag
1.3.6.1.4.1.868.2.4.1.2.2.27.1.205Columncmefg100VlanIngressVidMissread-writemandatoryIngress violation - the VLAN indicated by the frame's tag is undefined in the VLAN table.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.206Columncmefg100VlanPriMapTblread-writemandatoryA table containing new priority values for priority remapping. The SubDeviceIndex is 'original priority', range 0..7.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.207Columncmefg100VlanPriTagCtrlread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.208Columncmefg100VlanSetFailedread-onlymandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.209Columncmefg100VlanTagInread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.210Columncmefg100VlanTpDefaultPriread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.211Columncmefg100VlanTpDefaultVidread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.212Columncmefg100VlanTpInUntaggedDropread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.213Columncmefg100VlanUntagFiberTblread-onlymandatoryIndicates whether VLAN Ids are stripped from packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDe…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.214Columncmefg100VlanUntagTpTblread-onlymandatoryIndicates whether VLAN Ids are stripped from packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDe…
1.3.6.1.4.1.868.2.4.1.2.2.27.1.215Columncmefg100VlanVidTagCtrlread-writemandatory
1.3.6.1.4.1.868.2.4.1.2.2.27.1.216Columncmefg100VlanVidTblread-onlymandatoryThe SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries.
1.3.6.1.4.1.868.2.4.1.2.2.27.1.217Columncmefg100CacheCleanread-writemandatoryAnd all of the MIB variables lived happily ever after. The End.
1.3.6.1.4.1.868.2.4.2Nodebackplane
1.3.6.1.4.1.868.2.4.2.1Nodemcc16
1.3.6.1.4.1.868.2.4.2.1.1Nodemcc16Common
1.3.6.1.4.1.868.2.4.2.1.1.1Scalarmcc16ComHwResetread-writemandatorySave configuration to FLASH and perform a hardware reset
1.3.6.1.4.1.868.2.4.2.1.1.2Scalarmcc16ComMgmtHwRevread-onlymandatoryThe management h/w board revision.
1.3.6.1.4.1.868.2.4.2.1.1.3Scalarmcc16ComMgmtSwRevread-onlymandatoryThe downloadable management s/w code revision.
1.3.6.1.4.1.868.2.4.2.1.1.4Scalarmcc16ComIpAddrread-writemandatoryThe IP address of the management interface.
1.3.6.1.4.1.868.2.4.2.1.1.5Scalarmcc16ComNetMaskread-writemandatoryThe subnet mask associated with the IP address of the management interface. The value of the mask is an IP address with all the network bits set to 1 and all t…
1.3.6.1.4.1.868.2.4.2.1.1.6Scalarmcc16ComGatewayread-writemandatoryThe managment interface's default gateway.
1.3.6.1.4.1.868.2.4.2.1.1.7Scalarmcc16ComPS1Powerread-onlymandatoryOn if power supply 1 is installed and powered
1.3.6.1.4.1.868.2.4.2.1.1.8Scalarmcc16ComPS1InUseread-onlymandatoryOn if power supply 1 is currently active
1.3.6.1.4.1.868.2.4.2.1.1.9Scalarmcc16ComPS2Powerread-onlymandatoryOn if power supply 2 is installed and powered
1.3.6.1.4.1.868.2.4.2.1.1.10Scalarmcc16ComPS2InUseread-onlymandatoryOn if power supply 2 is currently active
1.3.6.1.4.1.868.2.4.2.1.1.11Scalarmcc16ComNotesread-writemandatoryEnduser-defined text notes
1.3.6.1.4.1.868.2.4.2.1.2Nodemcc16Ver1
1.3.6.1.4.1.868.2.4.2.1.2.1Tablemcc16SlotTablenot-accessiblemandatoryOne table entry per slot in the media converter chassis. Value of entry is type of device in the slot, or a value indicating that the slot is empty.
1.3.6.1.4.1.868.2.4.2.1.2.1.1Rowmcc16SlotEntrynot-accessiblemandatoryThe type of device inserted in a single chassis slot
1.3.6.1.4.1.868.2.4.2.1.2.1.1.1Columnmcc16Indexread-onlymandatoryThe index of a slot in a media converter chassis
1.3.6.1.4.1.868.2.4.2.1.2.1.1.2Columnmcc16DeviceTyperead-onlymandatoryThe object ID of the device in the a slot
1.3.6.1.4.1.868.2.4.2.2Nodecps
1.3.6.1.4.1.868.2.4.2.2.1NodecpsCabSummary
1.3.6.1.4.1.868.2.4.2.2.1.1TablecpsCabinetTablenot-accessiblemandatorySparse table containing one entry for each Cabinet in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.1.1.1RowcpsCabinetEntrynot-accessiblemandatoryStatus and Configuration entries for a single Cabinet.
1.3.6.1.4.1.868.2.4.2.2.1.1.1.1ColumncpsCabinetBiaIndexread-onlymandatoryThe serial number (BIA) of the Cabinet
1.3.6.1.4.1.868.2.4.2.2.1.1.1.2ColumncpsCabinetModelread-onlymandatoryThe model number of the cabinet
1.3.6.1.4.1.868.2.4.2.2.1.1.1.3ColumncpsCabinetDescriptionread-writemandatoryUser defined text description of the cabinet. This description is a mirror of the ones that can be found under cpsCabDetail.
1.3.6.1.4.1.868.2.4.2.2.1.1.1.4ColumncpsCabinetSequenceread-onlymandatoryAn arbitrary sequence number assigned to the cabinet by the agent for the use of the Focal Point application. Cabinets are sorted by BiaIndex in the table, and…
1.3.6.1.4.1.868.2.4.2.2.2NodecpsCabDetail
1.3.6.1.4.1.868.2.4.2.2.2.1TablecpsMc1800Tablenot-accessiblemandatorySparse table containing one entry for each CPSMC1800 in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.2.1.1RowcpsMc1800Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMC1800
1.3.6.1.4.1.868.2.4.2.2.2.1.1.1ColumncpsMc1800BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.1.1.2ColumncpsMc1800Descriptionread-onlymandatoryUser defined text description of the cabinet. A mirror of cpsCabinetDescription.
1.3.6.1.4.1.868.2.4.2.2.2.1.1.3ColumncpsMc1800PSPower1read-onlymandatoryPower status, first power supply slot. Value is on(1) when the supply is capable of supplying power.
1.3.6.1.4.1.868.2.4.2.2.2.1.1.4ColumncpsMc1800PSInUse1read-onlymandatoryPower status, first power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.1.1.5ColumncpsMc1800PSPower2read-onlymandatoryPower status, second power supply slot. Value is on(1) when the supply is capable of supplying power.
1.3.6.1.4.1.868.2.4.2.2.2.1.1.6ColumncpsMc1800PSInUse2read-onlymandatoryPower status, second power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.1.1.7ColumncpsMc1800MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.2.2.2.2TablecpsMc1300Tablenot-accessiblemandatorySparse table containing one entry for each CPSMC1300 in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.2.2.1RowcpsMc1300Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMC1300
1.3.6.1.4.1.868.2.4.2.2.2.2.1.1ColumncpsMc1300BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.2.1.2ColumncpsMc1300Descriptionread-onlymandatoryUser defined text description of the cabinet. A mirror of cpsCabinetDescription.
1.3.6.1.4.1.868.2.4.2.2.2.2.1.3ColumncpsMc1300PSPower1read-onlymandatoryPower status, first power supply slot. Value is on(1) when the supply is capable of supplying power.
1.3.6.1.4.1.868.2.4.2.2.2.2.1.4ColumncpsMc1300PSInUse1read-onlymandatoryFor future expansion. At the time of this writing, the CPSMC1300 did not accept any power supplies capable of supporting a master/slave relationship, meaning t…
1.3.6.1.4.1.868.2.4.2.2.2.2.1.5ColumncpsMc1300PSPower2read-onlymandatoryPower status, second power supply slot. Value is on(1) when the supply is capable of supplying power.
1.3.6.1.4.1.868.2.4.2.2.2.2.1.6ColumncpsMc1300PSInUse2read-onlymandatoryFor future expansion. At the time of this writing, the CPSMC1300 did not accept any power supplies capable of supporting a master/slave relationship, meaning t…
1.3.6.1.4.1.868.2.4.2.2.2.2.1.7ColumncpsMc1300MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.2.2.2.3TablecpsMc0200Tablenot-accessiblemandatorySparse table containing one entry for each CPSMC0200 in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.2.3.1RowcpsMc0200Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMC0200
1.3.6.1.4.1.868.2.4.2.2.2.3.1.1ColumncpsMc0200BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.3.1.2ColumncpsMc0200Descriptionread-onlymandatoryUser defined text description of the cabinet. A mirror of cpsCabinetDescription.
1.3.6.1.4.1.868.2.4.2.2.2.3.1.3ColumncpsMc0200MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.2.2.2.4TablecpsMc1900Tablenot-accessiblemandatorySparse table containing one entry for each CPSMC1900 in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.2.4.1RowcpsMc1900Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMC1900
1.3.6.1.4.1.868.2.4.2.2.2.4.1.1ColumncpsMc1900BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.4.1.2ColumncpsMc1900Descriptionread-onlymandatoryUser defined text description of the cabinet. A mirror of cpsCabinetDescription.
1.3.6.1.4.1.868.2.4.2.2.2.4.1.3ColumncpsMc1900MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.2.2.2.5Tablesmacf100Tablenot-accessiblemandatorySparse table containing one entry for each SMACF100 in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.2.5.1Rowsmacf100Entrynot-accessiblemandatoryStatus and configuration entries for a single SMACF100
1.3.6.1.4.1.868.2.4.2.2.2.5.1.1Columnsmacf100BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.5.1.2Columnsmacf100Descriptionread-onlymandatoryUser defined text description of the cabinet. A mirror of cpsCabinetDescription.
1.3.6.1.4.1.868.2.4.2.2.2.5.1.3Columnsmacf100MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.2.2.2.5.1.4Columnsmacf100SpanningTreeread-writemandatoryThis variable allows the agent to enable or disable Spanning Tree if it is supported. Not all versions of the hardware support Spanning Tree.
1.3.6.1.4.1.868.2.4.2.2.2.5.1.5Columnsmacf100ResetCountersread-writemandatoryWhen this variable is set to reset(1), all counters for all ports are reset to zero.
1.3.6.1.4.1.868.2.4.2.2.2.5.1.6Columnsmacf100SelfTestread-writemandatoryWhen this variable is set to selfTest(1), the cabinet will perform a self test.
1.3.6.1.4.1.868.2.4.2.2.2.5.1.7Columnsmacf100QosEnableread-writemandatoryThis variable allows Quality of Service functions to be enabled or disabled. This includes the processing of 802.1p tags (See smacf100QosHPThreshold(8), smacf1…
1.3.6.1.4.1.868.2.4.2.2.2.5.1.8Columnsmacf100QosHPThresholdread-writemandatoryWhen an incoming 802.1p priority tag value is greater than or equal to this value (from 0 to 7), the incoming packet will be classified as high-priority. Ignor…
1.3.6.1.4.1.868.2.4.2.2.2.5.1.9Columnsmacf100QosLqWeightread-writemandatoryA value between 1 and 15 indicating the number of packets that should be processed from the low-priority queue before attention is turned to the high-priority …
1.3.6.1.4.1.868.2.4.2.2.2.5.1.10Columnsmacf100QosHqWeightread-writemandatoryA value between 1 and 15 indicating the number of packets that should be processed from the high-priority queue before attention is turned to the low-priority …
1.3.6.1.4.1.868.2.4.2.2.2.5.1.11Columnsmacf100SNMPModuleInstalledread-onlymandatoryWhen this variable is set to yes(1), a management module is installed in this particular SMACF100 cabinet.
1.3.6.1.4.1.868.2.4.2.2.2.5.1.12Columnsmacf100AgingTimerread-writemandatoryThis configuration varible allows the MAC address aging timer to be adjusted. When an automatically discovered MAC address has not been heard from (i.e. no pac…
1.3.6.1.4.1.868.2.4.2.2.2.6TablecpsMc0800Tablenot-accessiblemandatorySparse table containing one entry for each CPSMC0800 in the stack, indexed by cabinet serial number.
1.3.6.1.4.1.868.2.4.2.2.2.6.1RowcpsMc0800Entrynot-accessiblemandatoryStatus and configuration entries for a single CPSMC0800
1.3.6.1.4.1.868.2.4.2.2.2.6.1.1ColumncpsMc0800BiaIndexread-onlymandatoryThe serial number (BIA) of the cabinet
1.3.6.1.4.1.868.2.4.2.2.2.6.1.2ColumncpsMc0800Descriptionread-onlymandatoryUser defined text description of the cabinet. A mirror of cpsCabinetDescription.
1.3.6.1.4.1.868.2.4.2.2.2.6.1.3ColumncpsMc0800MRevisionread-onlymandatoryThe marketing revision of this device
1.3.6.1.4.1.868.2.4.2.2.3NodecpsAgent
1.3.6.1.4.1.868.2.4.2.2.3.1ScalarcpsGroupCtrlread-writemandatoryThis string is used to select one or more groups of devices to receive mass configuration operations. When cpsGroupCtrl.0 is null, SNMP operations are performe…
1.3.6.1.4.1.868.2.4.2.2.3.2TablecpsSlotPwrTablenot-accessiblemandatorySparse table containing one power control entry for each slot in the stack, indexed by cabinet serial number and slot.
1.3.6.1.4.1.868.2.4.2.2.3.2.1RowcpsSlotPwrEntrynot-accessiblemandatoryThe power on/off control for a single Point System slot.
1.3.6.1.4.1.868.2.4.2.2.3.2.1.1ColumncpsSlotPwrBiaIndexread-onlymandatoryThe cabinet serial number (BIA) of the slot
1.3.6.1.4.1.868.2.4.2.2.3.2.1.2ColumncpsSlotPwrSlotIndexread-onlymandatoryThe slot number of the slot
1.3.6.1.4.1.868.2.4.2.2.3.2.1.3ColumncpsSlotPwrStateread-writemandatoryThe power control for the slot. When off(2), no power is supplied to the slot. If examined, the slot will appear empty.
1.3.6.1.4.1.868.2.4.2.2.3.3ScalarcpsIsPrimaryread-writemandatoryIndicates whether or not this Management Module is the primary Management Module in the stack. This variable contains the same information as the cpsmm100IsPri…
Type Definitions
NameSyntaxStatusDescription
CpsConnectorINTEGER { rj-45(10), stmm(11), stsm(12), scmm(13), scsm(14), scsmlh(15), scsmelh(16), scsmlhlw(17), mtrjmm(18), lc(19), bnc(20), stsmlh(21), stsmelh(22), scmm1300(23), stmm1300(24), mtrjsm(25), serial26(26), stmmlh(27), scsmsh(28), scsimplex(29), bncdual(30), db9rsxxx(31), termblock(32), rj11(33), sc40km(34), sc125km(35) }
MacAddressOCTET STRING (SIZE (6))