MCC16-MIB
1254 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises Gauge IpAddress TimeTicks |
| RFC1213-MIB | DisplayString PhysAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.868 | Nodetransition | |||
| 1.3.6.1.4.1.868.1 | NodeproductId | |||
| 1.3.6.1.4.1.868.1.4 | NodechassisProdsId | |||
| 1.3.6.1.4.1.868.1.4.1 | NodechassisSlotTypes | |||
| 1.3.6.1.4.1.868.1.4.1.1 | NodechSlMc20p | |||
| 1.3.6.1.4.1.868.1.4.1.1.1 | NodeceTbtFrl03Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.2 | NodeceCxTbt04Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.3 | NodeceCxFrl04Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.4 | NodecfSmMm02Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.5 | NodecfSmMm05Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.6 | NodecaCf02Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.7 | NodecfSmMm06Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.8 | Nodect1e1Cf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.9 | NodeceRTxFx01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.10 | Nodece100BtxFx04Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.12 | NodecpsCf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.13 | NodecbCf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.14 | NodecarCf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.15 | NodecarCf02Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.16 | NodecePswFx03Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.17 | NodecePswSx01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.18 | NodecRs232Cf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.24 | NodecfSmMm04Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.26 | Nodece100BtxSx01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.27 | Nodece100BtxFx04MtId | |||
| 1.3.6.1.4.1.868.1.4.1.1.28 | NodecfdCd01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.29 | NodectrCf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.30 | Nodece100BtxFrl03Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.31 | Nodemc20pEmptyId | |||
| 1.3.6.1.4.1.868.1.4.1.1.32 | Nodemc20pErrorId | |||
| 1.3.6.1.4.1.868.1.4.1.1.33 | Nodemc20pDblWideId | |||
| 1.3.6.1.4.1.868.1.4.1.1.34 | NodechstrCf01Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.35 | NodeceTxSx02Id | |||
| 1.3.6.1.4.1.868.1.4.1.1.36 | NodeceTbtFrl04Id | |||
| 1.3.6.1.4.1.868.1.4.1.2 | NodechSlcps | |||
| 1.3.6.1.4.1.868.1.4.1.2.1 | NodecpsmM100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.1.111 | NodepSError | A monitored MIB variable has changed from its 'operational' state to its 'error' state. | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.112 | NodepSErrorClear | A monitored MIB variable has changed from its 'error' state to its 'operational' state. | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.113 | NodepSDeviceInserted | A new slide-in device (this includes some power supplies) was detected on the bus. | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.114 | NodepSDeviceRemoved | A slide-in device that had previously been detected on the bus has not been heard from in a long time, and is presumed to have been physically removed. | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.115 | NodepSDeviceColdStart | A slide-in device has indicated that it has rebooted. This is most common when the device is inserted into its slot, but in a few cases this trap indicates a w… | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.116 | NodepSPowerLost | The cabinet into which this management module is installed has lost power. Both the cabinet and the management module must support this feature for this trap t… | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.117 | NodepSCabinetAdded | A new cabinet was detected on the bus. | ||
| 1.3.6.1.4.1.868.1.4.1.2.1.118 | NodepSCabinetRemoved | A cabinet that had previously been detected on the bus has not been heard from in a long time, and is presumed to have been physically removed. | ||
| 1.3.6.1.4.1.868.1.4.1.2.2 | NodecpsmM200Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.3 | Nodecettf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.4 | Nodecfetf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.5 | Nodecfmff100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.6 | Nodecpsmp100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.7 | Nodecsetf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.8 | Nodecgetf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.9 | Nodecsdtf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.10 | Nodecpsmp110Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.11 | Nodecbftf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.12 | Nodecetct100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.13 | Nodeccscf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.14 | Nodecfetf105Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.15 | Nodesmacf100PId | |||
| 1.3.6.1.4.1.868.1.4.1.2.16 | Nodecpsld100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.17 | Nodecdftf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.18 | Nodecpsvt100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.19 | Nodecemtf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.20 | Nodecaptf100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.21 | Nodecfetf205Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.22 | Nodecbftf150Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.23 | Nodecgfeb100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.24 | Nodecrmfe100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.25 | Nodecrs2f100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.26 | Nodecrs4f100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.27 | Nodecmefg100Id | |||
| 1.3.6.1.4.1.868.1.4.1.2.1001 | NodecpsEmptyId | |||
| 1.3.6.1.4.1.868.1.4.1.2.1002 | NodecpsDblWideId | |||
| 1.3.6.1.4.1.868.1.4.1.2.1003 | NodecpsUnknownDeviceId | |||
| 1.3.6.1.4.1.868.1.4.2 | NodechassisMcc16Id | |||
| 1.3.6.1.4.1.868.1.4.2.101 | Nodemcc16Error | A monitored MIB variable has changed from its 'operational' state to 'not present' or its 'error' state. | ||
| 1.3.6.1.4.1.868.1.4.2.102 | Nodemcc16ErrorClear | A monitored MIB variable has changed from a 'not present' or 'error' state to its 'operational' state. | ||
| 1.3.6.1.4.1.868.1.4.2.103 | Nodemcc16PSState | The power indication on a power supply has changed, or a power supply was non-operational at the time of a warm start. | ||
| 1.3.6.1.4.1.868.1.4.3 | NodechassisCpsmc1800Id | |||
| 1.3.6.1.4.1.868.1.4.4 | NodechassisCpsmc1850Id | |||
| 1.3.6.1.4.1.868.1.4.5 | NodechassisCpsmc0800Id | |||
| 1.3.6.1.4.1.868.1.4.6 | NodechassisCpsmc1300Id | |||
| 1.3.6.1.4.1.868.1.4.7 | NodechassisCpsmc0200Id | |||
| 1.3.6.1.4.1.868.1.4.8 | NodechassisSmacf100LCId | |||
| 1.3.6.1.4.1.868.1.4.9 | NodechassisCpsmc1900Id | |||
| 1.3.6.1.4.1.868.1.4.10 | NodechassisSmacf100Id | |||
| 1.3.6.1.4.1.868.2 | Nodeproducts | |||
| 1.3.6.1.4.1.868.2.4 | Nodechassis | |||
| 1.3.6.1.4.1.868.2.4.1 | Nodecard | |||
| 1.3.6.1.4.1.868.2.4.1.1 | NodeslotMc20p | |||
| 1.3.6.1.4.1.868.2.4.1.1.1 | TableceTbtFrl03Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TBT-FRL-03 media converter, then entry 'n' in this table e… |
| 1.3.6.1.4.1.868.2.4.1.1.1.1 | RowceTbtFrl03Entry | not-accessible | mandatory | State of LEDs on a single C/E-TBT-FRL-03 |
| 1.3.6.1.4.1.868.2.4.1.1.1.1.1 | ColumnceTbtFrl03Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.1.1.2 | ColumnceTbtFrl03FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.1.1.3 | ColumnceTbtFrl03FiberLink | read-only | mandatory | The state of the converter's Fiber Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.1.1.4 | ColumnceTbtFrl03TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.1.1.5 | ColumnceTbtFrl03TPLink | read-only | mandatory | The state of the converter's Twisted Pair Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.1.1.6 | ColumnceTbtFrl03Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.2 | TableceCxTbt04Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-CX-TBT-04 media converter, then entry 'n' in this table ex… |
| 1.3.6.1.4.1.868.2.4.1.1.2.1 | RowceCxTbt04Entry | not-accessible | mandatory | State of LEDs on a single C/E-CX-TBT-04 |
| 1.3.6.1.4.1.868.2.4.1.1.2.1.1 | ColumnceCxTbt04Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.2.1.2 | ColumnceCxTbt04Jabber | read-only | mandatory | The state of the converter's Jabber LED |
| 1.3.6.1.4.1.868.2.4.1.1.2.1.3 | ColumnceCxTbt04CoaxRecv | read-only | mandatory | The state of the converter's CoaxRecv LED |
| 1.3.6.1.4.1.868.2.4.1.1.2.1.4 | ColumnceCxTbt04TPRecv | read-only | mandatory | The state of the converter's TPRecv LED |
| 1.3.6.1.4.1.868.2.4.1.1.2.1.5 | ColumnceCxTbt04TPLink | read-only | mandatory | The state of the converter's TPLink LED |
| 1.3.6.1.4.1.868.2.4.1.1.2.1.6 | ColumnceCxTbt04Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.3 | TableceCxFrl04Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-CX-FRL-04 media converter, then entry 'n' in this table ex… |
| 1.3.6.1.4.1.868.2.4.1.1.3.1 | RowceCxFrl04Entry | not-accessible | mandatory | State of LEDs on a single C/E-CX-FRL-04 |
| 1.3.6.1.4.1.868.2.4.1.1.3.1.1 | ColumnceCxFrl04Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.3.1.2 | ColumnceCxFrl04Jabber | read-only | mandatory | The state of the converter's Jabber LED |
| 1.3.6.1.4.1.868.2.4.1.1.3.1.3 | ColumnceCxFrl04CoaxRecv | read-only | mandatory | The state of the converter's CoaxRecv LED |
| 1.3.6.1.4.1.868.2.4.1.1.3.1.4 | ColumnceCxFrl04FLRecv | read-only | mandatory | The state of the converter's FLRecv LED |
| 1.3.6.1.4.1.868.2.4.1.1.3.1.5 | ColumnceCxFrl04FLLink | read-only | mandatory | The state of the converter's FLLink LED |
| 1.3.6.1.4.1.868.2.4.1.1.3.1.6 | ColumnceCxFrl04Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.4 | TablecfSmMm02Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-02 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.4.1 | RowcfSmMm02Entry | not-accessible | mandatory | State of LEDs on a single C/F-SM-MM-02 |
| 1.3.6.1.4.1.868.2.4.1.1.4.1.1 | ColumncfSmMm02Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.4.1.2 | ColumncfSmMm02MMSignalDetect | read-only | mandatory | The state of the converter's MMSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.4.1.3 | ColumncfSmMm02SMSignalDetect | read-only | mandatory | The state of the converter's SMSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.4.1.4 | ColumncfSmMm02Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.5 | TablecfSmMm05Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-05 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.5.1 | RowcfSmMm05Entry | not-accessible | mandatory | State of LEDs on a single C/F-SM-MM-05 |
| 1.3.6.1.4.1.868.2.4.1.1.5.1.1 | ColumncfSmMm05Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.5.1.2 | ColumncfSmMm05SMSignalDetect | read-only | mandatory | The state of the converter's SMSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.5.1.3 | ColumncfSmMm05MMSignalDetect | read-only | mandatory | The state of the converter's MMSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.5.1.4 | ColumncfSmMm05Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.6 | TablecaCf02Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/A-CF-02 media converter, then entry 'n' in this table exists… |
| 1.3.6.1.4.1.868.2.4.1.1.6.1 | RowcaCf02Entry | not-accessible | mandatory | State of LEDs on a single C/A-CF-02 |
| 1.3.6.1.4.1.868.2.4.1.1.6.1.1 | ColumncaCf02Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.6.1.2 | ColumncaCf02CopperSignalDetect | read-only | mandatory | The state of the converter's CopperSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.6.1.3 | ColumncaCf02FiberSignalDetect | read-only | mandatory | The state of the converter's FiberSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.6.1.4 | ColumncaCf02Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.7 | TablecfSmMm06Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-06 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.7.1 | RowcfSmMm06Entry | not-accessible | mandatory | State of LEDs on a single C/F-SM-MM-06 |
| 1.3.6.1.4.1.868.2.4.1.1.7.1.1 | ColumncfSmMm06Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.7.1.2 | ColumncfSmMm06MMSignalDetect | read-only | mandatory | The state of the converter's MMSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.7.1.3 | ColumncfSmMm06SMSignalDetect | read-only | mandatory | The state of the converter's SMSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.7.1.4 | ColumncfSmMm06Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.8 | Tablect1e1Cf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/T1E1-CF-01 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.8.1 | Rowct1e1Cf01Entry | not-accessible | mandatory | State of LEDs on a single C/T1E1-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.8.1.1 | Columnct1e1Cf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.8.1.2 | Columnct1e1Cf01CopperSignalDetect | read-only | mandatory | The state of the converter's CopperSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.8.1.3 | Columnct1e1Cf01FiberSignalDetect | read-only | mandatory | The state of the converter's FiberSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.8.1.4 | Columnct1e1Cf01CoaxActive | read-only | mandatory | The state of the converter's Coax Active LED |
| 1.3.6.1.4.1.868.2.4.1.1.9 | TableceRTxFx01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-R-TX-FX-01 media converter, then entry 'n' in this table e… |
| 1.3.6.1.4.1.868.2.4.1.1.9.1 | RowceRTxFx01Entry | not-accessible | mandatory | State of LEDs on a single C/E-R-TX-FX-01 |
| 1.3.6.1.4.1.868.2.4.1.1.9.1.1 | ColumnceRTxFx01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.9.1.2 | ColumnceRTxFx01TPPrimary | read-only | mandatory | The state of the converter's Twisted Pair Primary LED |
| 1.3.6.1.4.1.868.2.4.1.1.9.1.3 | ColumnceRTxFx01FiberPrimary | read-only | mandatory | The state of the converter's Fiber Primary LED |
| 1.3.6.1.4.1.868.2.4.1.1.9.1.4 | ColumnceRTxFx01TPSignalDetect | read-only | mandatory | The state of the converter's Twisted Pair Signal Detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.9.1.5 | ColumnceRTxFx01FiberSignalDetect | read-only | mandatory | The state of the converter's Fiber Signal Detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.10 | Tablece100BtxFx04Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-FX-04(ST/SC) media converter, then entry 'n' in th… |
| 1.3.6.1.4.1.868.2.4.1.1.10.1 | Rowce100BtxFx04Entry | not-accessible | mandatory | State of LEDs on a single C/E-100-BTX-FX-04(ST/SC) |
| 1.3.6.1.4.1.868.2.4.1.1.10.1.1 | Columnce100BtxFx04Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.10.1.2 | Columnce100BtxFx04TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.10.1.3 | Columnce100BtxFx04FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.10.1.4 | Columnce100BtxFx04TPSignalDetect | read-only | mandatory | The state of the converter's Twisted Pair signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.10.1.5 | Columnce100BtxFx04FiberSignalDetect | read-only | mandatory | The state of the converter's fiber signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.10.1.6 | Columnce100BtxFx04Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.12 | TablecpsCf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/PS-CF-01 media converter, then entry 'n' in this table exist… |
| 1.3.6.1.4.1.868.2.4.1.1.12.1 | RowcpsCf01Entry | not-accessible | mandatory | State of LEDs on a single C/PS-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.12.1.1 | ColumncpsCf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.12.1.2 | ColumncpsCf01FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.12.1.3 | ColumncpsCf01TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.12.1.4 | ColumncpsCf01Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.13 | TablecbCf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/B-CF-01 media converter, then entry 'n' in this table exists… |
| 1.3.6.1.4.1.868.2.4.1.1.13.1 | RowcbCf01Entry | not-accessible | mandatory | State of LEDs on a single C/B-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.13.1.1 | ColumncbCf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.13.1.2 | ColumncbCf01FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.13.1.3 | ColumncbCf01TPCoaxRecv | read-only | mandatory | The state of the converter's Twisted Pair/Coax Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.13.1.4 | ColumncbCf01Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.14 | TablecarCf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/AR-CF-01 media converter, then entry 'n' in this table exist… |
| 1.3.6.1.4.1.868.2.4.1.1.14.1 | RowcarCf01Entry | not-accessible | mandatory | State of LEDs on a single C/AR-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.14.1.1 | ColumncarCf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.14.1.2 | ColumncarCf01FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.14.1.3 | ColumncarCf01TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.14.1.4 | ColumncarCf01Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.15 | TablecarCf02Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/AR-CF-02 media converter, then entry 'n' in this table exist… |
| 1.3.6.1.4.1.868.2.4.1.1.15.1 | RowcarCf02Entry | not-accessible | mandatory | State of LEDs on a single C/AR-CF-02 |
| 1.3.6.1.4.1.868.2.4.1.1.15.1.1 | ColumncarCf02Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.15.1.2 | ColumncarCf02FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.15.1.3 | ColumncarCf02CoaxRecv | read-only | mandatory | The state of the converter's Coax Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.15.1.4 | ColumncarCf02Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.16 | TablecePswFx03Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-PSW-FX-03 ethernet switch, then entry 'n' in this table ex… |
| 1.3.6.1.4.1.868.2.4.1.1.16.1 | RowcePswFx03Entry | not-accessible | mandatory | State of LEDs on a single C/E-PSW-FX-03 |
| 1.3.6.1.4.1.868.2.4.1.1.16.1.1 | ColumncePswFx03Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.16.1.2 | ColumncePswFx03TPFullDuplex | read-only | mandatory | The state of the converter's Twisted Pair FDX LED |
| 1.3.6.1.4.1.868.2.4.1.1.16.1.3 | ColumncePswFx03FiberFullDuplex | read-only | mandatory | The state of the converter's Fiber FDX LED |
| 1.3.6.1.4.1.868.2.4.1.1.16.1.4 | ColumncePswFx03TPLink | read-only | mandatory | The state of the converter's Twisted Pair Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.16.1.5 | ColumncePswFx03FiberLink | read-only | mandatory | The state of the converter's Fiber Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.16.1.6 | ColumncePswFx03TP100Mbps | read-only | mandatory | The state of the converter's Twisted Pair 100Mbps LED |
| 1.3.6.1.4.1.868.2.4.1.1.17 | TablecePswSx01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-PSW-SX-01 ethernet switch, then entry 'n' in this table ex… |
| 1.3.6.1.4.1.868.2.4.1.1.17.1 | RowcePswSx01Entry | not-accessible | mandatory | State of LEDs on a single C/E-PSW-SX-01 |
| 1.3.6.1.4.1.868.2.4.1.1.17.1.1 | ColumncePswSx01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.17.1.2 | ColumncePswSx01TPFullDuplex | read-only | mandatory | The state of the converter's Twisted Pair FDX LED |
| 1.3.6.1.4.1.868.2.4.1.1.17.1.3 | ColumncePswSx01FiberFullDuplex | read-only | mandatory | The state of the converter's Fiber FDX LED |
| 1.3.6.1.4.1.868.2.4.1.1.17.1.4 | ColumncePswSx01TPLink | read-only | mandatory | The state of the converter's Twisted Pair Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.17.1.5 | ColumncePswSx01FiberLink | read-only | mandatory | The state of the converter's Fiber Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.17.1.6 | ColumncePswSx01TP100Mbps | read-only | mandatory | The state of the converter's Twisted Pair 100Mbps LED |
| 1.3.6.1.4.1.868.2.4.1.1.18 | TablecRs232Cf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/RS232-CF-01 media converter, then entry 'n' in this table ex… |
| 1.3.6.1.4.1.868.2.4.1.1.18.1 | RowcRs232Cf01Entry | not-accessible | mandatory | State of LEDs on a single C/RS232-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.18.1.1 | ColumncRs232Cf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.18.1.2 | ColumncRs232Cf01FiberLock | read-only | mandatory | The state of the converter's Fiber Lock LED |
| 1.3.6.1.4.1.868.2.4.1.1.24 | TablecfSmMm04Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/F-SM-MM-04 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.24.1 | RowcfSmMm04Entry | not-accessible | mandatory | State of LEDs on a single C/F-SM-MM-04 |
| 1.3.6.1.4.1.868.2.4.1.1.24.1.1 | ColumncfSmMm04Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.24.1.2 | ColumncfSmMm04MMSignalDetect | read-only | mandatory | The state of the converter's Multi-Mode signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.24.1.3 | ColumncfSmMm04SMSignalDetect | read-only | mandatory | The state of the converter's Single-Mode signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.24.1.4 | ColumncfSmMm04Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.26 | Tablece100BtxSx01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-SX-01 media converter, then entry 'n' in this tabl… |
| 1.3.6.1.4.1.868.2.4.1.1.26.1 | Rowce100BtxSx01Entry | not-accessible | mandatory | State of LEDs on a single C/E-100-BTX-SX-01 |
| 1.3.6.1.4.1.868.2.4.1.1.26.1.1 | Columnce100BtxSx01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.26.1.2 | Columnce100BtxSx01TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.26.1.3 | Columnce100BtxSx01FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.26.1.4 | Columnce100BtxSx01TPSignalDetect | read-only | mandatory | The state of the converter's Twisted Pair signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.26.1.5 | Columnce100BtxSx01FiberSignalDetect | read-only | mandatory | The state of the converter's fiber signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.26.1.6 | Columnce100BtxSx01Power | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.27 | Tablece100BtxFx04MtTable | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100-BTX-FX-04(MT) media converter, then entry 'n' in this … |
| 1.3.6.1.4.1.868.2.4.1.1.27.1 | Rowce100BtxFx04MtEntry | not-accessible | mandatory | State of LEDs on a single C/E-100-BTX-FX-04(MT) |
| 1.3.6.1.4.1.868.2.4.1.1.27.1.1 | Columnce100BtxFx04MtIndex | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.27.1.2 | Columnce100BtxFx04MtTPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.27.1.3 | Columnce100BtxFx04MtFiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.27.1.4 | Columnce100BtxFx04MtTPSignalDetect | read-only | mandatory | The state of the converter's Twisted Pair signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.27.1.5 | Columnce100BtxFx04MtFiberSignalDetect | read-only | mandatory | The state of the converter's fiber signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.27.1.6 | Columnce100BtxFx04MtPower | read-only | mandatory | The state of the converter's Power LED |
| 1.3.6.1.4.1.868.2.4.1.1.28 | TablecfdCd01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/FD-CD-01 media converter, then entry 'n' in this table exist… |
| 1.3.6.1.4.1.868.2.4.1.1.28.1 | RowcfdCd01Entry | not-accessible | mandatory | State of LEDs on a single C/FD-CD-01 |
| 1.3.6.1.4.1.868.2.4.1.1.28.1.1 | ColumncfdCd01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.28.1.2 | ColumncfdCd01Lock | read-only | mandatory | The state of the converter's Lock LED |
| 1.3.6.1.4.1.868.2.4.1.1.28.1.3 | ColumncfdCd01TPRecv | read-only | mandatory | The state of the converter's TPRecv LED |
| 1.3.6.1.4.1.868.2.4.1.1.28.1.4 | ColumncfdCd01FiberRecv | read-only | mandatory | The state of the converter's FiberRecv LED |
| 1.3.6.1.4.1.868.2.4.1.1.28.1.5 | ColumncfdCd01TPSignalDetect | read-only | mandatory | The state of the converter's TPSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.28.1.6 | ColumncfdCd01FiberSignalDetect | read-only | mandatory | The state of the converter's FiberSignalDetect LED |
| 1.3.6.1.4.1.868.2.4.1.1.29 | TablectrCf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/TR-CF-01 media converter, then entry 'n' in this table exist… |
| 1.3.6.1.4.1.868.2.4.1.1.29.1 | RowctrCf01Entry | not-accessible | mandatory | State of LEDs on a single C/TR-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.29.1.1 | ColumnctrCf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.29.1.2 | ColumnctrCf01FiberinOK | read-only | mandatory | The state of the converter's FiberinOK LED |
| 1.3.6.1.4.1.868.2.4.1.1.29.1.3 | ColumnctrCf01TPinOK | read-only | mandatory | The state of the converter's TPinOK LED |
| 1.3.6.1.4.1.868.2.4.1.1.29.1.4 | ColumnctrCf01Inserted | read-only | mandatory | The state of the converter's Inserted LED |
| 1.3.6.1.4.1.868.2.4.1.1.30 | Tablece100BtxFrl03Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-100BTX-FRL-03 media converter, then entry 'n' in this tabl… |
| 1.3.6.1.4.1.868.2.4.1.1.30.1 | Rowce100BtxFrl03Entry | not-accessible | mandatory | State of LEDs on a single C/E-100BTX-FRL-03 |
| 1.3.6.1.4.1.868.2.4.1.1.30.1.1 | Columnce100BtxFrl03Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.30.1.2 | Columnce100BtxFrl03Lock | read-only | mandatory | The state of the converter's signal lock pin |
| 1.3.6.1.4.1.868.2.4.1.1.30.1.3 | Columnce100BtxFrl03TPRecv | read-only | mandatory | The state of the converter's Twisted pair receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.30.1.4 | Columnce100BtxFrl03FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.30.1.5 | Columnce100BtxFrl03TPSignalDetect | read-only | mandatory | The state of the converter's Twisted pair signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.30.1.6 | Columnce100BtxFrl03FiberSignalDetect | read-only | mandatory | The state of the converter's Fiber signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.34 | TablechstrCf01Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/HSTR-CF-01 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.34.1 | RowchstrCf01Entry | not-accessible | mandatory | State of LEDs on a single C/HSTR-CF-01 |
| 1.3.6.1.4.1.868.2.4.1.1.34.1.1 | ColumnchstrCf01Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.34.1.2 | ColumnchstrCf01TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.34.1.3 | ColumnchstrCf01FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.34.1.4 | ColumnchstrCf01TPSignalDetect | read-only | mandatory | The state of the converter's Twisted Pair signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.34.1.5 | ColumnchstrCf01FiberSignalDetect | read-only | mandatory | The state of the converter's fiber signal detect LED |
| 1.3.6.1.4.1.868.2.4.1.1.35 | TableceTxSx02Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TX-SX-02 media converter, then entry 'n' in this table exi… |
| 1.3.6.1.4.1.868.2.4.1.1.35.1 | RowceTxSx02Entry | not-accessible | mandatory | State of LEDs on a single C/E-TX-SX-02 |
| 1.3.6.1.4.1.868.2.4.1.1.35.1.1 | ColumnceTxSx02Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.35.1.2 | ColumnceTxSx02TPLink | read-only | mandatory | The state of the converter's Twisted Pair Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.35.1.3 | ColumnceTxSx02FiberLink | read-only | mandatory | The state of the converter's Fiber Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.35.1.4 | ColumnceTxSx02100Mbps | read-only | mandatory | The state of the converter's 100 Megabit Per Second LED |
| 1.3.6.1.4.1.868.2.4.1.1.36 | TableceTbtFrl04Table | not-accessible | mandatory | One table entry per slot in the media converter chassis. If physical slot 'n' contains a working C/E-TBT-FRL-04 media converter, then entry 'n' in this table e… |
| 1.3.6.1.4.1.868.2.4.1.1.36.1 | RowceTbtFrl04Entry | not-accessible | mandatory | State of LEDs on a single C/E-TBT-FRL-04 |
| 1.3.6.1.4.1.868.2.4.1.1.36.1.1 | ColumnceTbtFrl04Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.1.1.36.1.2 | ColumnceTbtFrl04FiberRecv | read-only | mandatory | The state of the converter's Fiber Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.36.1.3 | ColumnceTbtFrl04FiberLink | read-only | mandatory | The state of the converter's Fiber Link LED |
| 1.3.6.1.4.1.868.2.4.1.1.36.1.4 | ColumnceTbtFrl04TPRecv | read-only | mandatory | The state of the converter's Twisted Pair Receive LED |
| 1.3.6.1.4.1.868.2.4.1.1.36.1.5 | ColumnceTbtFrl04TPLink | read-only | mandatory | The state of the converter's Twisted Pair Link LED |
| 1.3.6.1.4.1.868.2.4.1.2 | NodeslotCps | |||
| 1.3.6.1.4.1.868.2.4.1.2.1 | NodecpsSlotSummary | |||
| 1.3.6.1.4.1.868.2.4.1.2.1.1 | TablecpsModuleTable | not-accessible | mandatory | A table from which one can extract the model number of any device in the stack, given the serial number (BIA) of the cabinet and the slot number in which the d… |
| 1.3.6.1.4.1.868.2.4.1.2.1.1.1 | RowcpsModuleEntry | not-accessible | mandatory | The model number entry for a single device. |
| 1.3.6.1.4.1.868.2.4.1.2.1.1.1.1 | ColumncpsModuleBiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.1.1.1.2 | ColumncpsModuleSlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.1.1.1.3 | ColumncpsModuleModel | read-only | mandatory | The model number of the device. See OIDs under chSlcps |
| 1.3.6.1.4.1.868.2.4.1.2.2 | NodecpsSlotDetail | |||
| 1.3.6.1.4.1.868.2.4.1.2.2.1 | Tablecpsmm100Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMM100-200 and other CPSMM100-xxx Point System Base Management Module in the stack, indexed by cabinet serial numb… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1 | Rowcpsmm100Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMM100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.1 | Columncpsmm100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.2 | Columncpsmm100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.3 | Columncpsmm100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.4 | Columncpsmm100Reset | read-write | mandatory | Set this to reset(1) to cause the CPSMM100 to reboot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.5 | Columncpsmm100SaveConfig | read-write | mandatory | Set this to saveConfig(1) to force configuration changes made since the last saveConfig to be copied from RAM to flash memory. If changes are made to the confi… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.6 | Columncpsmm100HwRevision | read-only | mandatory | The hardware revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.7 | Columncpsmm100SwRevision | read-only | mandatory | The revision of the agent firmware for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.8 | Columncpsmm100IPAddress | read-write | mandatory | The IP Address of the Ethernet interface of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.9 | Columncpsmm100SubnetMask | read-write | mandatory | The subnet mask used by the Ethernet interface of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.10 | Columncpsmm100Gateway | read-write | mandatory | The IP gateway used by the Ethernet interface of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.11 | Columncpsmm100IsPrimary | read-only | mandatory | In a given Point System stack, multiple base management modules can be installed, but only one can be the Primary. The Primary is responsible for scanning the … |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.12 | Columncpsmm100WantPrimary | read-write | mandatory | Normally, the Management Module installed in the cabinet with the lowest serial number (BIA) in the lowest (leftmost) slot that has fully established network c… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.13 | Columncpsmm100CanPrimary | read-only | mandatory | Value is yes(1) if this device is eligible to become the Primary Management Module. Currently, lack of IP/Ethernet connectivity is the only reason that a modul… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.14 | Columncpsmm100EthernetLink | read-only | mandatory | Does the management interface of this management module have ethernet link? |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.15 | Columncpsmm100TntRIP | read-only | mandatory | This feature in obsolete as of 08/17/2001. Telnet 'trusted' IP address. Telnet access to the CPSMM100 can be limited to a single station by placing its IP addr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.16 | Columncpsmm100TntRIPMask | read-only | mandatory | This feature in obsolete as of 08/17/2001. Telnet 'trusted' address mask. See cpsmm100TntRIP. This value can be used to exclude bit positions from consideratio… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.17 | Columncpsmm100SNMPTrapMgr | read-write | mandatory | Traps generated by this management module will be sent to this IP address. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.18 | Columncpsmm100SNMPTrapInterval | read-write | mandatory | For future expansion, not currently implemented. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.19 | Columncpsmm100SysUpTime | read-only | mandatory | Mirror of this Management Module's system.sysUpTime.0 |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.20 | Columncpsmm100SysContact | read-write | mandatory | Mirror of this Management Module's system.sysContact.0 |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.21 | Columncpsmm100SysName | read-write | mandatory | Mirror of this Management Module's system.sysName.0 |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.22 | Columncpsmm100SysLocation | read-write | mandatory | Mirror of this Management Module's system.sysLocation.0 |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.23 | Columncpsmm100CfgMatch | read-write | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.24 | Columncpsmm100SerialNumber | read-only | mandatory | The serial number of this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.25 | Columncpsmm100ICIF | read-only | mandatory | Multiple Management Modules can be installed in a Point System stack. For each cabinet in the stack, exactly one module must be selected to communicate configu… |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.26 | Columncpsmm100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.27 | Columncpsmm100LastGasp | read-only | mandatory | Last Gasp support for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.28 | Columncpsmm100SNMPTrapMgr2 | read-write | mandatory | Traps generated by this management module will be sent to this IP address. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.29 | Columncpsmm100SNMPTrapMgr3 | read-write | mandatory | Traps generated by this management module will be sent to this IP address. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.30 | Columncpsmm100SNMPTrapMgr4 | read-write | mandatory | Traps generated by this management module will be sent to this IP address. |
| 1.3.6.1.4.1.868.2.4.1.2.2.1.1.31 | Columncpsmm100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.2 | Tablecpsmm200Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMM200-210 and other CPSMM200-xxx Point System Expansion Management Module in the stack, indexed by cabinet serial… |
| 1.3.6.1.4.1.868.2.4.1.2.2.2.1 | Rowcpsmm200Entry | not-accessible | mandatory | Status entries for a single cpsmm200. (The CPSMM200 has no configuration) |
| 1.3.6.1.4.1.868.2.4.1.2.2.2.1.1 | Columncpsmm200BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.2.1.2 | Columncpsmm200SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.2.1.3 | Columncpsmm200SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.2.1.4 | Columncpsmm200ICIF | read-only | mandatory | Multiple Management Modules can be installed in a Point System stack. For each cabinet in the stack, exactly one module must be selected to communicate configu… |
| 1.3.6.1.4.1.868.2.4.1.2.2.2.1.5 | Columncpsmm200MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3 | Tablecettf100Table | not-accessible | mandatory | Sparse table containing one entry for each CETTF100 10Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and sl… |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1 | Rowcettf100Entry | not-accessible | mandatory | Status and configuration entries for a single CETTF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.1 | Columncettf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.2 | Columncettf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.3 | Columncettf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.4 | Columncettf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.5 | Columncettf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.6 | Columncettf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.7 | Columncettf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.8 | Columncettf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.9 | Columncettf100TPLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.10 | Columncettf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.11 | Columncettf100Fault | read-only | mandatory | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.12 | Columncettf100TPActivity | read-only | mandatory | Network traffic indicator for Copper side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.13 | Columncettf100FiberActivity | read-only | mandatory | Network traffic indicator for Fiber side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.14 | Columncettf100AutoCross | read-write | mandatory | Enable/Disable for automatic copper TX/RX pair correction |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.15 | Columncettf100LinkPassThrough | read-write | mandatory | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.16 | Columncettf100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.17 | Columncettf100Enabled | read-write | mandatory | When this configuration item is set to no(2), the device passes no network traffic. |
| 1.3.6.1.4.1.868.2.4.1.2.2.3.1.18 | Columncettf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4 | Tablecfetf100Table | not-accessible | mandatory | Sparse table containing one entry for each CFTEF100 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1 | Rowcfetf100Entry | not-accessible | mandatory | Status and configuration entries for a single CFETF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.1 | Columncfetf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.2 | Columncfetf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.3 | Columncfetf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.4 | Columncfetf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.5 | Columncfetf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.6 | Columncfetf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.7 | Columncfetf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.8 | Columncfetf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.9 | Columncfetf100TPLink | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.10 | Columncfetf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.11 | Columncfetf100Fault | read-only | mandatory | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.12 | Columncfetf100FastLinkPulse | read-write | mandatory | When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the convert… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.13 | Columncfetf100Enabled | read-write | mandatory | When this configuration item is set to no(2), the device passes no network traffic. |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.14 | Columncfetf100Pause | read-write | mandatory | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.15 | Columncfetf100LinkPassThrough | read-write | mandatory | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.16 | Columncfetf100AutoCross | read-write | mandatory | Enable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode. |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.17 | Columncfetf100TPActivity | read-only | mandatory | Network traffic indicator for Copper side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.18 | Columncfetf100FiberActivity | read-only | mandatory | Network traffic indicator for Fiber side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.19 | Columncfetf100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.20 | Columncfetf100FarEndFault | read-write | mandatory | Far End Fault configuration of this device. This setting can only be changed by the physical jumper setting on the slide in card, for some devices, if it is av… |
| 1.3.6.1.4.1.868.2.4.1.2.2.4.1.21 | Columncfetf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.5 | Tablecfmff100Table | not-accessible | mandatory | Sparse table containing one entry for each CFMFF100 SingleMode to MultiMode Fiber Media Converter in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1 | Rowcfmff100Entry | not-accessible | mandatory | Status and configuration entries for a single CFMFF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.1 | Columncfmff100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.2 | Columncfmff100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.3 | Columncfmff100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.4 | Columncfmff100MRevision | read-only | mandatory | The marketing revision of the device |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.5 | Columncfmff100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.6 | Columncfmff100ConnA | read-only | mandatory | The style of SingleMode connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.7 | Columncfmff100ConnB | read-only | mandatory | The style of MultiMode connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.8 | Columncfmff100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.9 | Columncfmff100SMSignal | read-only | mandatory | Status of singlemode signal detect for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.10 | Columncfmff100MMSignal | read-only | mandatory | Status of singlemode signal detect for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.11 | Columncfmff100Enabled | read-write | mandatory | Ports on this device can be disabled individually. When this control is set to yes(1), the entire device is enabled. When it is set to noP1(2), the SingleMode … |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.12 | Columncfmff100PortShutOff | read-only | mandatory | This variable reflects the status of the DPT/OPP jumper on the board. This jumper controls the behavior of the converter when a loss of signal is detected. Whe… |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.13 | Columncfmff100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.5.1.14 | Columncfmff100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.6 | Tablecpsmp100Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMP100 IFO (Instant Fail-Over) Power Supply in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1 | Rowcpsmp100Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMP100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.1 | Columncpsmp100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.2 | Columncpsmp100SlotIndex | read-only | mandatory | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.3 | Columncpsmp100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.4 | Columncpsmp100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.5 | Columncpsmp100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.6 | Columncpsmp100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.7 | Columncpsmp100Mode | read-write | mandatory | When one power supply is set to master(1) and the other is set to slave(2), the master will supply all power to the cabinet, and the slave will take over if th… |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.8 | Columncpsmp100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.9 | Columncpsmp100RemoteFan | read-only | mandatory | A Remote Fan is a device that fits in a power supply slot but contains no power supply, only a fan. These devices are not manageable, but if present they will … |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.10 | Columncpsmp100PowerOK | read-only | mandatory | This variable has the value yes(1) any time this supply is capable of supplying at least 11.6 volts to the cabinet. Note that a value of no(2) does not necessa… |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.11 | Columncpsmp100InUse | read-only | mandatory | Value is yes(1) when this supply is currently selected to supply power to the cabinet. |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.12 | Columncpsmp100ChassisPower | read-only | mandatory | Power currently supplied to the cabinet, in milliwatts |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.13 | Columncpsmp100ChassisTemp | read-only | mandatory | The temperature inside the cabinet as detected by the power supply, in tenths of degrees centigrade |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.14 | Columncpsmp100RFanFault | read-only | mandatory | Normally no(2), this value changes to yes(1) when an installed Remote fan is drawing excessive current or none at all. |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.15 | Columncpsmp100LFanFault | read-only | mandatory | Normally no(2), this value changes to yes(1) when the Local fan is drawing excessive current or none at all. |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.16 | Columncpsmp100SupplyType | read-only | mandatory | The supply voltage that this unit is designed to accept. If AC(1), the supply accepts 90-260VAC, 47 to 400Hz. If DC48(2), the supply accepts 38-75VDC. |
| 1.3.6.1.4.1.868.2.4.1.2.2.6.1.17 | Columncpsmp100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.7 | Tablecsetf100Table | not-accessible | mandatory | Sparse table containing one entry for each CSETF100 10/100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number an… |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1 | Rowcsetf100Entry | not-accessible | mandatory | One table entry per piece of management module information. Entry 'n' does not exist. |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.1 | Columncsetf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.2 | Columncsetf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.3 | Columncsetf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.4 | Columncsetf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.5 | Columncsetf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.6 | Columncsetf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.7 | Columncsetf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.8 | Columncsetf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.9 | Columncsetf100TPLink | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.10 | Columncsetf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.11 | Columncsetf100AutoCross | read-write | mandatory | Enable/Disable for automatic copper TX/RX pair correction |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.12 | Columncsetf100SpeedConfig | read-write | mandatory | This variable allows the user to set the requested data transfer rate for this converter. |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.13 | Columncsetf100Speed100Mbps | read-only | mandatory | This variable reports the current data transfer rate for this converter. |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.14 | Columncsetf100TPActivity | read-only | mandatory | Network traffic indicator for Copper side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.15 | Columncsetf100FiberActivity | read-only | mandatory | Network traffic indicator for Fiber side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.16 | Columncsetf100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.7.1.17 | Columncsetf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8 | Tablecgetf100Table | not-accessible | mandatory | Sparse table containing one entry for each CGETF100 Gigabit Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1 | Rowcgetf100Entry | not-accessible | mandatory | One table entry per piece of management module information. Entry 'n' does not exist. |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.1 | Columncgetf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.2 | Columncgetf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.3 | Columncgetf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.4 | Columncgetf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.5 | Columncgetf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.6 | Columncgetf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.7 | Columncgetf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.8 | Columncgetf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.9 | Columncgetf100TPLink | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.10 | Columncgetf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.11 | Columncgetf100Fault | read-only | mandatory | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.12 | Columncgetf100Enabled | read-write | mandatory | When this variable is set to no(1), the device allows no traffic to pass. |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.13 | Columncgetf100Pause | read-write | mandatory | Enable/Disable control for the advertising of Pause capability on the copper interface. This MIB variable is retained for compatibility with older applications… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.14 | Columncgetf100LinkPassThrough | read-write | mandatory | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.15 | Columncgetf100FullDuplex | read-write | mandatory | Controls advertizing of duplex capability for the copper side of the converter. When set to fullDuplex(1), the converter advertizes full duplex capability. Whe… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.16 | Columncgetf100ClockMaster | read-only | mandatory | When yes(1), the converter is supplying clock to the twisted pair. When no(2), the remote supplies the clock. |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.17 | Columncgetf100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.18 | Columncgetf100TPLength | read-only | mandatory | Twisted-pair length estimated via the converter's internal Time Domain Reflectometer. 1 means less than 50 meters, 2 means 50 to 80 meters, 3 means 80 to 110 m… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.19 | Columncgetf100FiberAutoNegot | read-write | mandatory | Fiber port autonegotiation configuration. |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.20 | Columncgetf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.8.1.21 | Columncgetf100PauseType | read-write | mandatory | Enable/Disable control for the advertising of Pause capability on the copper interface. This MIB variable is only functional on CGETF100 devices that support a… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9 | Tablecsdtf100Table | not-accessible | mandatory | Sparse table containing one entry for each CSDTF100 T1/E1 Copper to Fiber Media Converter in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1 | Rowcsdtf100Entry | not-accessible | mandatory | Status and configuration entries for a single CSDTF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.1 | Columncsdtf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.2 | Columncsdtf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.3 | Columncsdtf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.4 | Columncsdtf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.5 | Columncsdtf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.6 | Columncsdtf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.7 | Columncsdtf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.8 | Columncsdtf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.9 | Columncsdtf100CopperLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.10 | Columncsdtf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.11 | Columncsdtf100Fault | read-only | mandatory | Value is yes(1) when either CopperLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.12 | Columncsdtf100TAOSFiber | read-write | mandatory | Transmit All Ones on Fiber as an error signal when Copper interface is down. When this error signal is transmitted, the AIS of the device on the other end is a… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.13 | Columncsdtf100TAOSCopper | read-write | mandatory | Transmit All Ones on Copper as an error signal when Fiber interface is down. When this error signal is transmitted, the AIS of the device on the other end is a… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.14 | Columncsdtf100AISFiber | read-only | mandatory | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.15 | Columncsdtf100AISCopper | read-only | mandatory | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.16 | Columncsdtf100CopperLoopback | read-write | mandatory | Enable loopback on the copper interface. Copper Loopback causes all data that is sent to the copper interface to be transmitted back out the copper interface. … |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.17 | Columncsdtf100CopperLongHaul | read-only | mandatory | This variable indicates the current position of the device's long/short haul configuration switch. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.18 | Columncsdtf100T1E1 | read-only | mandatory | This variable indicates whether the current device is the T1 or the E1 version. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.19 | Columncsdtf100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.20 | Columncsdtf100TPCoax | read-only | mandatory | Indicates the connector type installed on the copper interface. For E1 converters, this can be either Twisted Pair or Coax. For T1, it is always Twisted Pair. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.21 | Columncsdtf100CopperLineBuildout | read-only | mandatory | The characteristics of the copper interface |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.22 | Columncsdtf100FiberLoopback | read-write | mandatory | Enable loopback on the Fiber interface. Fiber Loopback causes all data that is sent to the Fiber interface to be transmitted back out the Fiber interface. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.23 | Columncsdtf100RmtSupported | read-only | mandatory | Has the value yes(1) if this converter is capable of managing the media converter at the remote end of the fiber. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.24 | Columncsdtf100RmtDetected | read-only | mandatory | Has the value yes(1) if management communcations have been established with a remote media converter. Always no(2) if TAOS is enabled or the remote converter d… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.25 | Columncsdtf100RmtMRevision | read-only | mandatory | Remote Marketing Revision. Same as csdtf100MRevision, only for the remote device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.26 | Columncsdtf100RmtSerialNumber | read-only | mandatory | Serial Number reported by remote device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.27 | Columncsdtf100RmtConnA | read-only | mandatory | The style of Fiber connector reported by remote device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.28 | Columncsdtf100RmtConnB | read-only | mandatory | The style of Fiber connector reported by remote device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.29 | Columncsdtf100RmtCopperLink | read-only | mandatory | Link status of remote Copper Port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.30 | Columncsdtf100RmtFiberLink | read-only | mandatory | Link status of remote Fiber Port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.31 | Columncsdtf100RmtFault | read-only | mandatory | Remote Fault status. Value is yes(1) when either CopperLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.32 | Columncsdtf100RmtTAOSFiber | read-write | mandatory | Remote Fiber TAOS configuration. Transmit All Ones on Fiber as an error signal when Copper interface is down. When this error signal is transmitted, the AIS of… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.33 | Columncsdtf100RmtTAOSCopper | read-write | mandatory | Remote Copper TAOS configuration. Transmit All Ones on Copper as an error signal when Fiber interface is down. When this error signal is transmitted, the AIS o… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.34 | Columncsdtf100RmtAISFiber | read-only | mandatory | Remote Fiber AIS status. Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.35 | Columncsdtf100RmtAISCopper | read-only | mandatory | Remote Copper AIS status. Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alar… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.36 | Columncsdtf100RmtCopperLoopback | read-write | mandatory | Remote Copper Loopback configuration. Enable loopback on the copper interface. Copper Loopback causes all data that is sent to the copper interface to be trans… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.37 | Columncsdtf100RmtCopperLongHaul | read-only | mandatory | This variable indicates the current position of the remote device's Short/Long haul configuration switch. |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.38 | Columncsdtf100RmtConfigMode | read-only | mandatory | Remote Configuration Mode. This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management … |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.39 | Columncsdtf100RmtTPCoax | read-only | mandatory | Indicates the connector type installed on the remote copper interface. For E1 converters, this can be either Twisted Pair or Coax. For T1, it is always Twisted… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.40 | Columncsdtf100RmtCopperLineBuildout | read-only | mandatory | The electrical characteristics of the remote Copper interface. Values are the same as the values for csdtf100CopperLineBuildout(21) |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.41 | Columncsdtf100RmtFiberLoopback | read-write | mandatory | Enable loopback on the remote Fiber interface. Fiber Loopback causes all data that is sent to the Fiber interface to be transmitted back out the Fiber interfac… |
| 1.3.6.1.4.1.868.2.4.1.2.2.9.1.42 | Columncsdtf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10 | Tablecpsmp110Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMP110 IFO (Instant Fail-Over) Power Supply in the stack. indexed by sub-device index, cabinet serial number, and … |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1 | Rowcpsmp110Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMP100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.1 | Columncpsmp110SubDeviceIndex | read-only | mandatory | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.2 | Columncpsmp110BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for … |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.3 | Columncpsmp110SlotIndex | read-only | mandatory | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placehol… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.4 | Columncpsmp110Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.5 | Columncpsmp110MRevision | read-only | mandatory | The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.6 | Columncpsmp110CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.7 | Columncpsmp110SerialNumber | read-only | mandatory | The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.8 | Columncpsmp110ConfigMode | read-only | mandatory | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.9 | Columncpsmp110MasterTempFault | read-only | mandatory | The master temperature fault indicator for this device. A value of yes(1) indicates that at least one temperature sensor encountered a fault condition since th… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.10 | Columncpsmp110MasterCurrentFault | read-only | mandatory | The master current fault indicator for this device. A value of yes(1) indicates that at least one current sensor encountered a fault condition since the last t… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.11 | Columncpsmp110MasterFanFault | read-only | mandatory | The master fan fault indicator for this device. A value of yes(1) indicates that at least one fan current sensor encountered a fault condition since the last t… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.12 | Columncpsmp110FirmwareRevision | read-only | mandatory | The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.13 | Columncpsmp110PSSupplyTbl | read-only | mandatory | The supply voltage that this unit is designed to accept. If AC(1), the supply accepts VAC. If DC(2), the supply accepts. A single CPSMP110 control unit can sup… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.14 | Columncpsmp110PSRoleTbl | read-write | mandatory | Some power supplies support a Master/Slave relationship: When one power supply is set to master(1) and the other is set to slave(2), the master will supply all… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.15 | Columncpsmp110PSReadyTbl | read-only | mandatory | The readiness of this power supply module. A value of yes(1) indicates the module is ready to supply power to the cabinet. A value of no(2) indicates that the … |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.16 | Columncpsmp110PSInUseTbl | read-only | mandatory | The use status of this power supply module. A value of yes(1) indicates the module is supplying power to the cabinet. This variable is useful in configurations… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.17 | Columncpsmp110TemperatureTbl | read-only | mandatory | The temperature, in tenths of degrees centigrade, read by this temperature sensor. A single CPSMP110 control unit can support multiple subdevices of this type. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.18 | Columncpsmp110CurrentTbl | read-only | mandatory | The current, in milliwatts, read by this current sensor. A single CPSMP110 control unit can support multiple subdevices of this type. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.19 | Columncpsmp110FanStatusTbl | read-only | mandatory | The status of a fan. A value of fault(2) indicates that the control unit has detected a problem with the fan, usually that it is is drawing excessive current. … |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.20 | Columncpsmp110TempFaultTbl | read-only | mandatory | Each entry in this column corresponds to an entry with the same indices in cpsmp110TemperatureTable. It indicates whether or not the temperature read by the se… |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.21 | Columncpsmp110CurrFaultTbl | read-only | mandatory | Each entry in this column corresponds to an entry with the same indices in cpsmp110CurrentTable. It indicates whether or not the current read by the sensor is … |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.22 | Columncpsmp110PSCount | read-only | mandatory | The maximum number of power supplies supported in this configuration. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.23 | Columncpsmp110TempSensorCount | read-only | mandatory | The number of temperature sensors supported in this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.24 | Columncpsmp110CurrSensorCount | read-only | mandatory | The number of current sensors supported in this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.25 | Columncpsmp110FanCount | read-only | mandatory | The number of fans supported in this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.10.1.26 | Columncpsmp110CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11 | Tablecbftf100Table | not-accessible | mandatory | Sparse table containing one entry for each CBFTF100 switch in the stack. Indexed by sub-device index, cabinet serial number, and slot. Note that some columns o… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1 | Rowcbftf100Entry | not-accessible | mandatory | Status and configuration entries for a single CBFTF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.1 | Columncbftf100SubDeviceIndex | read-only | mandatory | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.2 | Columncbftf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for … |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.3 | Columncbftf100SlotIndex | read-only | mandatory | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placehol… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.4 | Columncbftf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.5 | Columncbftf100MRevision | read-only | mandatory | The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.6 | Columncbftf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.7 | Columncbftf100SerialNumber | read-only | mandatory | The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.8 | Columncbftf100ConfigMode | read-only | mandatory | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.9 | Columncbftf100FirmwareRevision | read-only | mandatory | The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.10 | Columncbftf100SelfTestFailed | read-only | mandatory | This variable indicates the status of the pass/fail power on test. If the power on test fails, normal operation of this device is probably not possible. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.11 | Columncbftf100SpanningTree | read-write | mandatory | This variable allows the agent to enable or disable Spanning Tree if it is supported. Not all versions of the hardware support Spanning Tree. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.12 | Columncbftf100MirrorCfg | read-write | mandatory | Global enable/disable for mirror port functionality. When this variable is set to disabled, the values of cbftf100MirrorSelTbl, cbftf100MirrorInTbl, and cbftf1… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.13 | Columncbftf100SACMasterCfg | read-write | mandatory | Global enable/disable for Source Address Change detection functionality. When this variable is set to disabled the values in cbtf100SACCfgTbl are ignored. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.14 | Columncbftf100FormFactor | read-only | mandatory | A code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number of physical connectors present… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.15 | Columncbftf100AutoNegotTbl | read-write | mandatory | Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are multiple subdevices in this table, … |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.16 | Columncbftf100FullDuplexTbl | read-write | mandatory | In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports wit… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.17 | Columncbftf100100MbpsTbl | read-write | mandatory | In most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, this is a status indication sho… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.18 | Columncbftf100Adv10HDXTbl | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, half duplex. This setting is not supported on fiber p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.19 | Columncbftf100Adv10FDXTbl | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, full duplex. This setting is not supported on fiber p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.20 | Columncbftf100Adv100HDXTbl | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, half duplex. This setting is not supported on fiber … |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.21 | Columncbftf100Adv100FDXTbl | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, full duplex. This setting is not supported on fiber … |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.22 | Columncbftf100CrossTbl | read-write | mandatory | Configuration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs if necessary. If autonegotiat… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.23 | Columncbftf100PauseCfgTbl | read-write | mandatory | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. A setting of enabled(1) causes this port to advertis… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.24 | Columncbftf100PauseStatTbl | read-only | mandatory | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. A value of paused(1) indicated the port is in a paus… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.25 | Columncbftf100FarEndFaultTbl | read-write | mandatory | When Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform the device at the far end of the… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.26 | Columncbftf100ConnectorTbl | read-only | mandatory | The style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.27 | Columncbftf100SACCfgTbl | read-write | mandatory | This configuration setting controls whether changes in source MAC address are reported. When set to enabled(1), a change in MAC address will result in a moment… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.28 | Columncbftf100SACStatTbl | read-only | mandatory | This status value indicates whether or not the source MAC address attached to this port changed in the last polling period. This value tends to change quite qu… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.29 | Columncbftf100MirrorSelTbl | read-write | mandatory | This configuration setting allows a mirror port to be selected. The selected port will re-transmit copies of all packets transmitted on ports whose MirrorOutTb… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.30 | Columncbftf100MirrorInTbl | read-write | mandatory | This configuration setting allows a mirror source port to be selected. All packets received on each port with a MirrorInTbl setting of mirrorIn(1) will be retr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.31 | Columncbftf100MirrorOutTbl | read-write | mandatory | This configuration setting allows a mirror source port to be selected. All packets transmitted on each port with a MirrorInTbl setting of mirrorOut(1) will be … |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.32 | Columncbftf100LinkTbl | read-only | mandatory | This table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.33 | Columncbftf100PortCount | read-only | mandatory | A count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch. |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.34 | Columncbftf100LinkPassThrough | read-write | mandatory | If Link Passthrough is enabled on a port, loss of link on the opposite port will be propegated through to this port so that the switch does not prevent one end… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.35 | Columncbftf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.11.1.36 | Columncbftf100RedundantPath | read-only | mandatory | This variable shows the status of the redundant fiber capability. If the value is enabled(1), this means that the hardware switch to enable redundant fiber is … |
| 1.3.6.1.4.1.868.2.4.1.2.2.12 | Tablecetct100Table | not-accessible | mandatory | Sparse table containing one entry for each CETCT100 10Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and sl… |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1 | Rowcetct100Entry | not-accessible | mandatory | Status and configuration entries for a single CETCT100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.1 | Columncetct100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.2 | Columncetct100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.3 | Columncetct100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.4 | Columncetct100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.5 | Columncetct100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.6 | Columncetct100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.7 | Columncetct100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.8 | Columncetct100FirmwareRevision | read-only | mandatory | The firmware revision level for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.9 | Columncetct100TPLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.10 | Columncetct100Collision | read-only | mandatory | This status variable indicates whether or not an Ethernet collision occurred during the most recent polling cycle. |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.11 | Columncetct100CoaxActivity | read-only | mandatory | This status variable indicates whether or not Ethernet traffic was detected on the Coax interface during the most recent polling cycle. |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.12 | Columncetct100TPActivity | read-only | mandatory | This status variable indicates whether or not Ethernet traffic was detected on the Twisted Pair interface during the most recent polling cycle. |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.13 | Columncetct100CollisionsPerMinute | read-only | mandatory | The number of Ethernet collisions that occurred during the most recently completed measured minute. Every 60 seconds, the device moves its previous collision c… |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.14 | Columncetct100CollisionsPerHour | read-only | mandatory | The number of Ethernet collisions that occurred during the most recently completed measured hour. Every 60 minutes, the device moves its previous collision cou… |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.15 | Columncetct100ConnA | read-only | mandatory | The style of media connector built into this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.16 | Columncetct100ConnB | read-only | mandatory | The style of media connector built into this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.12.1.17 | Columncetct100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.13 | Tableccscf100Table | not-accessible | mandatory | Sparse table containing one entry for each ccscf100 T3/E3 Copper to Fiber Media Converter in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1 | Rowccscf100Entry | not-accessible | mandatory | Status and configuration entries for a single ccscf100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.1 | Columnccscf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.2 | Columnccscf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.3 | Columnccscf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.4 | Columnccscf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.5 | Columnccscf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.6 | Columnccscf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.7 | Columnccscf100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.8 | Columnccscf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.9 | Columnccscf100CopperLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.10 | Columnccscf100AISFiber | read-only | mandatory | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition. |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.11 | Columnccscf100AISCopper | read-only | mandatory | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an alarm condition. |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.12 | Columnccscf100DS3LineBuildout | read-write | mandatory | The characteristics of the copper interface |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.13 | Columnccscf100E3DS3 | read-only | mandatory | This variable indicates whether the current device is the T1 or the E1 version. |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.14 | Columnccscf100CopperLoopback | read-write | mandatory | Enable loopback on the copper interface. |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.15 | Columnccscf100FiberLoopback | read-write | mandatory | Enable loopback on the copper interface. |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.16 | Columnccscf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.17 | Columnccscf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.13.1.18 | Columnccscf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.14 | Tablecfetf105Table | not-accessible | mandatory | Sparse table containing one entry for each CFTEF105 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s… |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1 | Rowcfetf105Entry | not-accessible | mandatory | Status and configuration entries for a single CFETF105 |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.1 | Columncfetf105BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.2 | Columncfetf105SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.3 | Columncfetf105Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.4 | Columncfetf105MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.5 | Columncfetf105CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.6 | Columncfetf105SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.7 | Columncfetf105ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.8 | Columncfetf105ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.9 | Columncfetf105TPLink | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.10 | Columncfetf105FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.11 | Columncfetf105AutoNegot | read-write | mandatory | Enable/Disable Autonegotiation |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.12 | Columncfetf105LinkPassThrough | read-write | mandatory | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.13 | Columncfetf105AutoCross | read-write | mandatory | Enable/Disable for automatic copper TX/RX pair correction |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.14 | Columncfetf105TPActivity | read-only | mandatory | Network traffic indicator for Copper side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.15 | Columncfetf105FiberActivity | read-only | mandatory | Network traffic indicator for Fiber side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.16 | Columncfetf105ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.14.1.17 | Columncfetf105CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15 | Tablesmacf100PTable | not-accessible | mandatory | Sparse table containing one entry for each SMACF100P virtual slide-in device. This table dexcribes ONE port on a SMACFxxx colony switch |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1 | Rowsmacf100PEntry | not-accessible | mandatory | Status and configuration entries for a single SMACF100P |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.1 | Columnsmacf100PSubDeviceIndex | read-only | mandatory | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices. T… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.2 | Columnsmacf100PBiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.3 | Columnsmacf100PSlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.4 | Columnsmacf100PGroups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.5 | Columnsmacf100PCfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.6 | Columnsmacf100PConnA | read-only | mandatory | The style of Fiber or Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.7 | Columnsmacf100PLink | read-only | mandatory | Status of Port Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.8 | Columnsmacf100P100Mbps | read-write | mandatory | Communication speed for this port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.9 | Columnsmacf100PFullDuplex | read-write | mandatory | In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports wit… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.10 | Columnsmacf100PSACStat | read-only | mandatory | This status value indicates whether or not the source MAC address attached to this port changed in the last polling period. This value tends to change quite qu… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.11 | Columnsmacf100PEnabled | read-write | mandatory | Status of of this Port. A value of yes(1) indicates this port is 'enabled'. A value of no(2) indicates this port is 'disabled'. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.12 | Columnsmacf100PAutoNegot | read-write | mandatory | Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.13 | Columnsmacf100PAdv10HDX | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, half duplex. This setting is not supported on fiber p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.14 | Columnsmacf100PAdv10FDX | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 10Mbps, full duplex. This setting is not supported on fiber p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.15 | Columnsmacf100PAdv100HDX | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, half duplex. This setting is not supported on fiber … |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.16 | Columnsmacf100PAdv100FDX | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 100Mbps, full duplex. This setting is not supported on fiber … |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.17 | Columnsmacf100PSTPState | read-write | mandatory | Port spanning tree state. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.18 | Columnsmacf100PLastMAC | read-only | mandatory | Last MAC Address this port communicated with. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.19 | Columnsmacf100PFarEndFaultCfg | read-write | mandatory | Far end fault configuration of this Port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.20 | Columnsmacf100PFarEndFaultStat | read-only | mandatory | Far end fault status of this port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.21 | Columnsmacf100PTxOctets | read-only | mandatory | The number of bytes of data transmitted through this interface. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.22 | Columnsmacf100PWrapTxOctets | read-only | mandatory | The number of times that the unsigned 32-bit smacf100PTxOctets(21) MIB variable has wrapped. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.23 | Columnsmacf100PRxOctets | read-only | mandatory | The number of bytes of data received through this interface. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.24 | Columnsmacf100PWrapRxOctets | read-only | mandatory | The number of times that the unsigned 32-bit smacf100PRxOctets(23) MIB variable has wrapped. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.25 | Columnsmacf100PSACCfg | read-write | mandatory | Source Address Change detection configuration. Enables or Disables the generation of traps related to source address change for this port. When disabled, the s… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.26 | Columnsmacf100PBlockMgmt | read-write | mandatory | Through this variable and others, the SMACF100 supports port- based VLANs. The SMACF100 will pass tags for IEEE 802.3ac VLANs, but will neither insert nor stri… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.27 | Columnsmacf100PBlockPort | read-write | mandatory | Through this variable and others, the SMACF100 supports port- based VLANs. The SMACF100 will pass tags for IEEE 802.3ac VLANs, but will neither insert nor stri… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.28 | Columnsmacf100PTxDropPkts | read-only | mandatory | This counter is incremented every time a transmit packet is dropped due to lack of resources (e.g. transmit FIFO underflow), or an internal MAC sublayer transm… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.29 | Columnsmacf100PTxBroadcastPkts | read-only | mandatory | The number of good packets transmitted by this port that are directed to a broadcast address. This counter includes neither errored broadcast packets nor valid… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.30 | Columnsmacf100PTxMulticastPkts | read-only | mandatory | The number of good packets transmitted by this port that are directed to a multicast address. This counter includes neither errored multicast packets nor valid… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.31 | Columnsmacf100PTxUnicastPkts | read-only | mandatory | The number of good packets transmitted by this port that are directed to a unicast address. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.32 | Columnsmacf100PTxCollisions | read-only | mandatory | The number of collisions experienced by this port during packet transmissions. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.33 | Columnsmacf100PTxSingleCollision | read-only | mandatory | The number of packets successfully transmitted by this port that experienced exactly one collision. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.34 | Columnsmacf100PTxMultipleCollision | read-only | mandatory | The number of packets successfully transmitted by this port that experienced more than one collision. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.35 | Columnsmacf100PTxDeferredTransmit | read-only | mandatory | The number of packets transmitted by a this port for which the first transmission attempt was delayed because the medium was busy. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.36 | Columnsmacf100PTxLateCollision | read-only | mandatory | The number of times that a collision was detected later than 512 bit-times into the transmission of a packet. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.37 | Columnsmacf100PTxExcessiveCollision | read-only | mandatory | The number of packets that were not transmitted from this port because 16 unsucessful attempts were made to transmit the packet. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.38 | Columnsmacf100PTxFrameInDisc | read-only | mandatory | The number of valid packets received which are discarded by the forwarding process due to lack of space on an output queue. This attribute only increments if a… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.39 | Columnsmacf100PTxPausePkts | read-write | mandatory | The number of PAUSE frames transmitted by this port. This implies that the port is in full duplex mode and that 802.3x flow control was enabled at the completi… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.40 | Columnsmacf100PRxUndersizePkts | read-only | mandatory | The number of good packets received by this port that are less than 64 bytes long (excluding framing bits but including the Frame Check Sequence). |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.41 | Columnsmacf100PRxPausePkts | read-write | mandatory | The number of PAUSE frames recieved by this port. The PAUSE frame must have a valid MAC Control Frame EtherType field (88- 08h), have a destination MAC address… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.42 | Columnsmacf100PPkts64Octets | read-only | mandatory | The number of packets, including error packets, that are 64 bytes long. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.43 | Columnsmacf100PPkts65to127Octets | read-only | mandatory | The number of packets, including error packets, that are between 65 and 127 bytes long. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.44 | Columnsmacf100PPkts128to255Octets | read-only | mandatory | The number of packets, including error packets, that are between 128 and 255 bytes long. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.45 | Columnsmacf100PPkts256to511Octets | read-only | mandatory | The number of packets, including error packets, that are between 256 and 511 bytes long. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.46 | Columnsmacf100PPkts512to1023Octets | read-only | mandatory | The number of packets, including error packets, that are between 512 and 1023 bytes long. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.47 | Columnsmacf100PPkts1024to1522Octets | read-only | mandatory | The number of packets, including error packets, that are between 1024 and 1522 bytes long. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.48 | Columnsmacf100PRxOversizePkts | read-only | mandatory | The number of good packets received by this port that are longer than 1522 bytes inclusive (excluding framing bits but including the Frame Check Sequence). Not… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.49 | Columnsmacf100PRxJabbers | read-only | mandatory | The number of packets received by a port that are longer than 1522 bytes and have either a Frame Check Sequence error or an alignment error. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.50 | Columnsmacf100PRxAlignmentErrors | read-only | mandatory | The number of packets received by this port that have a length (excluding framing bits but including the Frame Check Sequence) between 64 and 1522 bytes inclus… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.51 | Columnsmacf100PRxFCSErrors | read-only | mandatory | The number of packets received by this port that have a length (excluding framing bits but including the Frame Check Sequence) between 64 and 1522 bytes inclus… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.52 | Columnsmacf100PRxGoodOctets | read-only | mandatory | The total number of bytes in all good packets received by a port (excluding framing bits but including Frame Check Sequences). |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.53 | Columnsmacf100PWrapRxGoodOctets | read-only | mandatory | The number of times that the unsigned 32-bit smacf100PRxGoodOctets(52) MIB variable for this port has wrapped. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.54 | Columnsmacf100PRxDropPkts | read-only | mandatory | The number of good packets received by this port that were dropped due to lack of resources (e.g. lack of input buffers) or were dropped due to a lack of resou… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.55 | Columnsmacf100PRxUnicastPkts | read-only | mandatory | The number of good packets received by this port that are addressed to a unicast address. |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.56 | Columnsmacf100PRxMulticastPkts | read-only | mandatory | The number of good packets received by this port that are directed to a multicast address. This counter includes neither errored multicast packets nor valid br… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.57 | Columnsmacf100PRxBroadcastPkts | read-only | mandatory | The number of good packets received by this port that are directed to the broadcast address. This counter includes neither errored broadcast packets nor valid … |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.58 | Columnsmacf100PRxSAChanges | read-only | mandatory | The number of times the Source Ethernet Address of good receive packets has changed from the previous value. A count greater than one generally indicates that … |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.59 | Columnsmacf100PRxFragments | read-only | mandatory | The number of packets received by a port that are shorter than 64 bytes (excluding framing bits) and have either an Frame Check Sequence error or an alignment … |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.60 | Columnsmacf100PRxExcessSizeDisc | read-only | mandatory | The number of good packets received by this port that are longer than 1536 bytes (excluding framing bits but including Frame Check Sequences) and were discarde… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.61 | Columnsmacf100PRxSymbolError | read-only | mandatory | The total number of times this port received a packet which had a valid length, but contained at least one invalid symbol. The counter only increments once per… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.62 | Columnsmacf100PQosPriority | read-write | mandatory | When this variable is set to 'high(1)', this port becomes a high-priority port. This means that all packets received on this port for transission on other port… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.63 | Columnsmacf100PQosPause | read-write | mandatory | When the global variable smacf100QosEnable(7) is set to 'enabled(1)', then the port-specific variable smacf100PQosPause(63) controls whether or not the port su… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.64 | Columnsmacf100PAdvPause | read-write | mandatory | Enable/disable control for this advertised autonegotiation mode. When Pause capability is autonegotiated (at the Physical level), the MAC layer may then send P… |
| 1.3.6.1.4.1.868.2.4.1.2.2.15.1.65 | Columnsmacf100PCacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.16 | Tablecpsld100Table | not-accessible | mandatory | Sparse table containing one entry for each CPSLD100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1 | Rowcpsld100Entry | not-accessible | mandatory | Status and configuration entries for a single CPSLD100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.1 | Columncpsld100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.2 | Columncpsld100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.3 | Columncpsld100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.4 | Columncpsld100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.5 | Columncpsld100Ps1Power | read-only | mandatory | Power status, first power supply slot. Value is on(1) when the supply is capable of supplying power. |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.6 | Columncpsld100Ps1InUse | read-only | mandatory | Power status, first power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet. |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.7 | Columncpsld100Ps2Power | read-only | mandatory | Power status, second power supply slot. Value is on(1) when the supply is capable of supplying power. |
| 1.3.6.1.4.1.868.2.4.1.2.2.16.1.8 | Columncpsld100Ps2InUse | read-only | mandatory | Power status, second power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17 | Tablecdftf100Table | not-accessible | mandatory | Sparse table containing one entry for each CDFTF100 Dual telco Media Converter in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1 | Rowcdftf100Entry | not-accessible | mandatory | Status and configuration entries for a single CDFTF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.1 | Columncdftf100SubDeviceIndex | read-only | mandatory | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.2 | Columncdftf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.3 | Columncdftf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.4 | Columncdftf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.5 | Columncdftf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.6 | Columncdftf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.7 | Columncdftf100MRevision | read-only | mandatory | The marketing revision of the device |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.8 | Columncdftf100TPLinkTbl | read-only | mandatory | This table contains the link status of each twisted pair port in the CDFTF100. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.9 | Columncdftf100FiberLinkTbl | read-only | mandatory | This table contains the link status of each fiber port in the CDFTF100. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.10 | Columncdftf100TPActivityTbl | read-only | mandatory | Netowrk traffic indicator for the copper port(s) on this device. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.11 | Columncdftf100FiberActivityTbl | read-only | mandatory | Netowrk traffic indicator for the fiber port(s) on this device. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.12 | Columncdftf100ConnectorTbl | read-only | mandatory | This table contains the link status of each port of this device. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.13 | Columncdftf100FirmwareRevision | read-only | mandatory | The style of connectors built into each port of this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.17.1.14 | Columncdftf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18 | Tablecpsvt100Table | not-accessible | mandatory | Sparse table containing one entry for each CPSVT100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1 | Rowcpsvt100Entry | not-accessible | mandatory | Status and configuration entries for a single CPSVT100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.1 | Columncpsvt100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.2 | Columncpsvt100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.3 | Columncpsvt100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.4 | Columncpsvt100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.5 | Columncpsvt100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.6 | Columncpsvt100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.7 | Columncpsvt100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.8 | Columncpsvt100CopperLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.9 | Columncpsvt100Fault | read-only | mandatory | Value is yes(1) when either CopperLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.10 | Columncpsvt100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.11 | Columncpsvt100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.12 | Columncpsvt100TermTiming | read-write | mandatory | Local Terminal Timing setting. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends to the DCE. Since this signal can… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.13 | Columncpsvt100LoopBack | read-write | mandatory | Remote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.14 | Columncpsvt100CableMode | read-only | mandatory | A description of the type of cable that is attached to the Copper interface of the local device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.15 | Columncpsvt100DCE | read-only | mandatory | An indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this status is derived from the type … |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.16 | Columncpsvt100InvertTX | read-only | mandatory | Local transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of t… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.17 | Columncpsvt100InvertRX | read-only | mandatory | Local receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of th… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.18 | Columncpsvt100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.19 | Columncpsvt100FirmwareRev | read-only | mandatory | Local firmware revision. |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.20 | Columncpsvt100RmtDetected | read-only | mandatory | Has the value yes(1) if management communcations have been established with a remote media converter. |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.21 | Columncpsvt100RmtTermTiming | read-write | mandatory | Local Terminal Timing setting of the remotely managed CPSVTxxx. Terminal timing is a signal sent from a DCE to a DTE to control the rate of data the DTE sends … |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.22 | Columncpsvt100RmtLoopBack | read-write | mandatory | Remote fiber and copper loopback setting. Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.23 | Columncpsvt100RmtCableMode | read-write | mandatory | A description of the type of cable that is attached to the Copper interface of the local device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.24 | Columncpsvt100RmtDCE | read-write | mandatory | An indication of whether this device is attached to a DCE (a computer) or a DTE (a terminal). Like cpsvt100CableMode(14), this status is derived from the type … |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.25 | Columncpsvt100RmtInvertTX | read-write | mandatory | Local transmit clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of t… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.26 | Columncpsvt100RmtInvertRX | read-write | mandatory | Local receive clock usage. Some types of high-speed serial equipment read the data signal on the rising edge of the clock, and others on the falling edge of th… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.27 | Columncpsvt100RmtConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.28 | Columncpsvt100RmtFirmwareRev | read-only | mandatory | Local firmware revision. |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.29 | Columncpsvt100RmtCopperLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.30 | Columncpsvt100RmtFiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.18.1.31 | Columncpsvt100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.19 | Tablecemtf100Table | not-accessible | mandatory | Sparse table containing one entry for each CEMTF100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1 | Rowcemtf100Entry | not-accessible | mandatory | Status and configuration entries for a single CEMTF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.1 | Columncemtf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.2 | Columncemtf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.3 | Columncemtf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.4 | Columncemtf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.5 | Columncemtf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.6 | Columncemtf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.7 | Columncemtf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.8 | Columncemtf100OffHook | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.9 | Columncemtf100Fault | read-only | mandatory | Value is yes(1) when either OffHook or FiberLink has value of down |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.10 | Columncemtf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.11 | Columncemtf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.19.1.12 | Columncemtf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.20 | Tablecaptf100Table | not-accessible | mandatory | Sparse table containing one entry for each CAPTF100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1 | Rowcaptf100Entry | not-accessible | mandatory | Status and configuration entries for a single CAPTF100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.1 | Columncaptf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.2 | Columncaptf100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.3 | Columncaptf100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.4 | Columncaptf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.5 | Columncaptf100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.6 | Columncaptf100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.7 | Columncaptf100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.8 | Columncaptf100InUse | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.9 | Columncaptf100Fault | read-only | mandatory | Value is yes(1) when either OffHook or FiberLink has value of down |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.10 | Columncaptf100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.11 | Columncaptf100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.12 | Columncaptf100FirmwareRev | read-only | mandatory | The firmware revision level for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.13 | Columncaptf100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.20.1.14 | Columncaptf100Emulates | read-only | mandatory | This read-only variable indicates the emulation type and configuration of the device. CAPTF100 devices exist in two varieties, the CAPTF10033xx-100, the copper… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21 | Tablecfetf205Table | not-accessible | mandatory | Sparse table containing one entry for each CFTEF205 100Mbps Twisted-Pair to Fiber Ethernet Media Converter in the stack, indexed by cabinet serial number and s… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1 | Rowcfetf205Entry | not-accessible | mandatory | Status and configuration entries for a single CFETF205 |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.1 | Columncfetf205BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.2 | Columncfetf205SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.3 | Columncfetf205Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.4 | Columncfetf205MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.5 | Columncfetf205CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.6 | Columncfetf205SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.7 | Columncfetf205ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.8 | Columncfetf205ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.9 | Columncfetf205TPLink | read-only | mandatory | Status of Twisted Pair Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.10 | Columncfetf205FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.11 | Columncfetf205Fault | read-only | mandatory | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.12 | Columncfetf205FastLinkPulse | read-write | mandatory | When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the convert… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.13 | Columncfetf205Enabled | read-write | mandatory | When this configuration item is set to no(2), the device passes no network traffic. |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.14 | Columncfetf205Pause | read-write | mandatory | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.15 | Columncfetf205LinkPassThrough | read-write | mandatory | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to the other side, so that upstr… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.16 | Columncfetf205AutoCross | read-write | mandatory | Enable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode. |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.17 | Columncfetf205TPActivity | read-only | mandatory | Network traffic indicator for Copper side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.18 | Columncfetf205FiberActivity | read-only | mandatory | Network traffic indicator for Fiber side of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.19 | Columncfetf205ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.20 | Columncfetf205FarEndFault | read-write | mandatory | Far End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal d… |
| 1.3.6.1.4.1.868.2.4.1.2.2.21.1.21 | Columncfetf205CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22 | Tablecbftf150Table | not-accessible | mandatory | Sparse table containing one entry for each CBFTF150 switch in the stack. Indexed by sub-device index, cabinet serial number, and slot. Note that some columns o… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1 | Rowcbftf150Entry | not-accessible | mandatory | Status and configuration entries for a single CBFTF150 |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.1 | Columncbftf150SubDeviceIndex | read-only | mandatory | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.2 | Columncbftf150BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholder value 1 is always used for … |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.3 | Columncbftf150SlotIndex | read-only | mandatory | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices for this value, so the placehol… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.4 | Columncbftf150Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.5 | Columncbftf150MRevision | read-only | mandatory | The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.6 | Columncbftf150CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.7 | Columncbftf150SerialNumber | read-only | mandatory | The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.8 | Columncbftf150ConfigMode | read-only | mandatory | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.9 | Columncbftf150FirmwareRevision | read-only | mandatory | The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used for that index. |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.10 | Columncbftf150FormFactor | read-only | mandatory | A code corresponding to a physical configuration of the product. This code indicates the number of slots occupied and the number of physical connectors present… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.11 | Columncbftf150AutoNegotTbl | read-write | mandatory | Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. There are multiple subdevices in this table, … |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.12 | Columncbftf150FullDuplexTbl | read-write | mandatory | In most cases this is a configuration setting that controls the duplex mode; fullDuplex is full duplex and halfDuplex is half duplex. On twisted pair ports wit… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.13 | Columncbftf150100MbpsTbl | read-write | mandatory | In most cases this is a configuration setting that controls the link speed. On twisted pair ports with autonegotiation enabled, this is a status indication sho… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.14 | Columncbftf150CrossTbl | read-write | mandatory | Configuration setting for copper TX/RX pair correction. A setting of auto(1) causes the port to automatically correct TX/RX pairs if necessary. If autonegotiat… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.15 | Columncbftf150FarEndFaultTbl | read-write | mandatory | When Far End Fault is set to enabled(1), a loss of link on receive will cause the transmitter to shut down, in order to inform the device at the far end of the… |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.16 | Columncbftf150ConnectorTbl | read-only | mandatory | The style of connectors built into each port of this device. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.17 | Columncbftf150LinkTbl | read-only | mandatory | This table contains the link status of each port in the switch. There are multiple subdevices in this table, numbering one entry per port. |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.18 | Columncbftf150PortCount | read-only | mandatory | A count of the switch ports in this device. i.e. the maximum subdevice index supported by this switch. |
| 1.3.6.1.4.1.868.2.4.1.2.2.22.1.19 | Columncbftf150CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23 | Tablecgfeb100Table | not-accessible | mandatory | Sparse table containing one entry for each CGFEB100 10/100/1000 Ethernet to Fiber converter in the stack. Indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1 | Rowcgfeb100Entry | not-accessible | mandatory | Status and configuration entries for a single CGFEB100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.1 | Columncgfeb100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.2 | Columncgfeb100SlotIndex | read-only | mandatory | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.3 | Columncgfeb100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.4 | Columncgfeb100MRevision | read-only | mandatory | The marketing revision of this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.5 | Columncgfeb100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.6 | Columncgfeb100SerialNumber | read-only | mandatory | The serial number of this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.7 | Columncgfeb100ConfigMode | read-only | mandatory | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all c… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.8 | Columncgfeb100FirmwareRevision | read-only | mandatory | The firmware revision level for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.9 | Columncgfeb100SelfTestFailed | read-only | mandatory | This variable indicates the status of the pass/fail power on test. If the power on test fails, normal operation of this device is probably not possible. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.10 | Columncgfeb100MonitorType | read-only | mandatory | Some versions of this device support the monitoring of network traffic passing through the converter's fiber interface via a dedicated monitoring port to which… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.11 | Columncgfeb100LinkPassThrough | read-write | mandatory | This configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.12 | Columncgfeb100QosEnabled | read-write | mandatory | This variable allows Quality of Service functions to be enabled or disabled. This includes the processing of 802.1p tags (See cgfeb100QosHPThreshold(13), cgfeb… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.13 | Columncgfeb100QosHPThreshold | read-write | mandatory | When an incoming 802.1p priority tag value is greater than or equal to this value (from 0 to 7), the incoming packet will be classified as high-priority. Ignor… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.14 | Columncgfeb100QosLqWeight | read-write | mandatory | A value between 1 and 15 indicating the number of packets that should be processed from the low-priority queue before attention is turned to the high-priority … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.15 | Columncgfeb100QosHqWeight | read-write | mandatory | A value between 1 and 15 indicating the number of packets that should be processed from the high-priority queue before attention is turned to the low-priority … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.16 | Columncgfeb100ConnA | read-only | mandatory | The style of copper connector built into this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.17 | Columncgfeb100TPLink | read-only | mandatory | Twisted Pair link status. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.18 | Columncgfeb100TPSpeedCfg | read-write | mandatory | The desired speed of the Twisted Pair interface. This speed can be set to 10Mbps(1) or 100Mbps(2). Operation at 1000Mbps requires autonegotiation. When cgfeb10… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.19 | Columncgfeb100TPSpeedStat | read-only | mandatory | The actual speed of the Twisted Pair interface: 10Mbps(1), 100Mbps(2), or 1000Mbps(3). If cgfeb100TpAutonegot(24) has the value enabled(1) and cgfeb100TpLink(1… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.20 | Columncgfeb100TPFullDuplexCfg | read-write | mandatory | The desired duplex setting of the Twisted Pair interface. This can be set to fdx(1) (full duplex) or hdx(2) (half duplex). When cgfeb100TpAutonegot(24) has the… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.21 | Columncgfeb100TPFullDuplexStat | read-only | mandatory | The actual duplex behavior of the Twisted Pair interface. If cgfeb100TpAutonegot(24) has the value enabled(1) and cgfeb100TpLink(17) has the value down(2), thi… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.22 | Columncgfeb100TPCrossCfg | read-write | mandatory | The desired TX/RX Pair orientation of the Twisted Pair interface. This can be set to mdi(1) (straight through), mdix(2) (crossed over), or auto(3). When cgfeb1… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.23 | Columncgfeb100TPCrossStat | read-only | mandatory | The actual TX/RX Pair orientation of the Twisted Pair interface, usually mdi(1) (straight through) or mdix(2) (crossed over). When the device does not know the… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.24 | Columncgfeb100TPAutoNegot | read-write | mandatory | Enables or disables autonegtiation of link speed and duplex for twisted pair ports. Not supported on Fiber ports. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.25 | Columncgfeb100TPAdv10HDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.26 | Columncgfeb100TPAdv10FDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.27 | Columncgfeb100TPAdv100HDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.28 | Columncgfeb100TPAdv100FDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.29 | Columncgfeb100TPAdv1000HDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.30 | Columncgfeb100TPAdv1000FDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.31 | Columncgfeb100TPLpAdvPause | read-only | mandatory | This read-only variable shows the pause capability advertised by the twisted pair port's link partner. Values 1 through 4 for this variable are the same as tho… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.32 | Columncgfeb100TPLpAdv10HDX | read-write | mandatory | This read-only variable shows twisted pair port's link partner's willingness to connect at 10Mbps Half Duplex. If the device does not support the reporting of … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.33 | Columncgfeb100TPLpAdv10FDX | read-only | mandatory | This read-only variable shows twisted pair port's link partner's willingness to connect at 10Mbps Full Duplex. If the device does not support the reporting of … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.34 | Columncgfeb100TPLpAdv100HDX | read-only | mandatory | This read-only variable shows twisted pair port's link partner's willingness to connect at 100Mbps Half Duplex. If the device does not support the reporting of… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.35 | Columncgfeb100TPLpAdv100FDX | read-only | mandatory | This read-only variable shows twisted pair port's link partner's willingness to connect at 100Mbps Full Duplex. If the device does not support the reporting of… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.36 | Columncgfeb100TPLpAdv1000HDX | read-only | mandatory | This read-only variable shows twisted pair port's link partner's willingness to connect at 1000Mbps Half Duplex. If the device does not support the reporting o… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.37 | Columncgfeb100TPLpAdv1000FDX | read-only | mandatory | This read-only variable shows twisted pair port's link partner's willingness to connect at 1000Mbps Full Duplex. If the device does not support the reporting o… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.38 | Columncgfeb100TPAdvPause | read-write | mandatory | Enable/disable control for autonegotiation advertising of Twisted Pair Pause capability. Selectable values are symmetric(1), asymRX(2) (asymmetric, pause frame… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.39 | Columncgfeb100TPQosPause | read-write | mandatory | This variable allows Twisted Pair Quality Of Service Pause to be enabled or disabled. When cgfeb100QosEnabled(12) is set to enabled(1) and this variable is set… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.40 | Columncgfeb100TPSacCfg | read-write | mandatory | This variable allows Source Address Change traps to be enabled or disabled. If enabled, 'Error' traps will be sent as frequently one per polling cycle any time… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.41 | Columncgfeb100TPSacStat | read-only | mandatory | This read-only variable has the value changed(1) if the Ethernet source address received on the Twisted Pair interface changed since the device's previous repo… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.42 | Columncgfeb100ConnB | read-only | mandatory | The style of Fiber connector built into this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.43 | Columncgfeb100FiberLink | read-only | mandatory | The Fiber Link status for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.44 | Columncgfeb100FiberFullDuplexCfg | read-write | mandatory | The desired duplex setting of the Fiber interface. This can be set to fdx(1) (full duplex) or hdx(2) (half duplex). When cgfeb100TpAutonegot(24) has the value … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.45 | Columncgfeb100FiberFullDuplexStat | read-only | mandatory | The actual duplex behavior of the Fiber interface: fdx(1) (full duplex) or hdx(2) (half duplex). If cgfeb100FiberAutonegot(46) has the value disabled(2) and th… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.46 | Columncgfeb100FiberAutoNegot | read-write | mandatory | Autonegotiation configuration. Fiber autonegotiation is limited to the duplex setting. The fiber's speed is fixed at 1000Mbps. |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.47 | Columncgfeb100FiberAdv1000HDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.48 | Columncgfeb100FiberAdv1000FDX | read-write | mandatory | Enable/disable control for these advertised autonegotiation modes. If autonegotiation is disabled (because cgfeb100TpAutonegot(24) has the value disabled(2) or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.49 | Columncgfeb100FiberLpAdv1000HDX | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 1000Mbps, half duplex. This setting is not supported on fiber… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.50 | Columncgfeb100FiberLpAdv1000FDX | read-write | mandatory | This configuration setting controls whether or not each port advertises willingness to connect at 1000Mbps, full duplex. This setting is not supported on fiber… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.51 | Columncgfeb100FiberLpAdvPause | read-only | mandatory | This read-only variable shows the pause capability advertised by the fiber port's link partner. Values 1 through 4 for this variable are the same as those for … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.52 | Columncgfeb100FiberAdvPause | read-write | mandatory | Enable/disable control for autonegotiation advertising of Fiber Pause capability. Selectable values are symmetric(1), asymRX(2) (asymmetric, pause frames flow … |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.53 | Columncgfeb100FiberQosPause | read-write | mandatory | This variable allows Fiber Quality Of Service Pause to be enabled or disabled. When cgfeb100QosEnabled(12) is set to enabled(1) and this variable is set to dis… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.54 | Columncgfeb100FiberSacCfg | read-write | mandatory | This variable allows Source Address Change traps to be enabled or disabled. If enabled, 'Error' traps will be sent as frequently one per polling cycle any time… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.55 | Columncgfeb100FiberSacStat | read-write | mandatory | This read-only variable has the value changed(1) if the Ethernet source address received on the fiber interface changed since the device's previous report to t… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.56 | Columncgfeb100MonitorTap | read-write | mandatory | Before reading this description, see cgfeb100MonitorType(10). This variable controls which side of the fiber port (transmit(1) or receive(2)) is monitored by t… |
| 1.3.6.1.4.1.868.2.4.1.2.2.23.1.57 | Columncgfeb100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24 | Tablecrmfe100Table | not-accessible | mandatory | Sparse table containing one entry for each CRMFE100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1 | Rowcrmfe100Entry | not-accessible | mandatory | Status and configuration entries for a single CRMFE100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.1 | Columncrmfe100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.2 | Columncrmfe100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.3 | Columncrmfe100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.4 | Columncrmfe100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.5 | Columncrmfe100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.6 | Columncrmfe100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.7 | Columncrmfe100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.8 | Columncrmfe100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.9 | Columncrmfe100TPLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.10 | Columncrmfe100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.11 | Columncrmfe100Fault | read-only | mandatory | Value is yes(1) when either CopperLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.12 | Columncrmfe100Autonegot | read-write | mandatory | Autonegotiation configuration for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.13 | Columncrmfe100Enabled | read-write | mandatory | When the Enabled configuration item is set to no(2), the converter passes no network traffic in either direction. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.14 | Columncrmfe100Pause | read-write | mandatory | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.15 | Columncrmfe100LinkPassThrough | read-write | mandatory | This configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.16 | Columncrmfe100AutoCross | read-write | mandatory | On certain devices, it is possible for hardware to automatically correct errors in cable selection, making the distinction between a 'straight through' cable a… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.17 | Columncrmfe100TPActivity | read-only | mandatory | Twisted Pair Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be n… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.18 | Columncrmfe100FiberActivity | read-only | mandatory | Fiber Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notAppli… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.19 | Columncrmfe100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.20 | Columncrmfe100FarEndFault | read-write | mandatory | Far End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal d… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.21 | Columncrmfe100NetworkMode | read-only | mandatory | Read-only indicator for High Speed Token Ring jumper configuration. If the variable reads tokenRing(1), then the converter is jumpered for High Speed Token Rin… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.22 | Columncrmfe100UpTime | read-write | mandatory | Time since the last reboot in Time Ticks (hundredths of seconds). If the value 0 is written to this variable, the timer is reset. No other write value is accep… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.23 | Columncrmfe100FirmwareRevision | read-only | mandatory | Firmware revision level of this CRMFE100. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.24 | Columncrmfe100RmtDetected | read-only | mandatory | Has the value yes(1) if management communcations have been established with a remote media converter. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.25 | Columncrmfe100RmtTPLink | read-only | mandatory | Status of Copper Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.26 | Columncrmfe100RmtFiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.27 | Columncrmfe100RmtFault | read-only | mandatory | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.28 | Columncrmfe100RmtAutonegot | read-write | mandatory | Autonegotiation configuration for this device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.29 | Columncrmfe100RmtPause | read-write | mandatory | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is negotiated at the physical leve… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.30 | Columncrmfe100RmtLinkPassThrough | read-write | mandatory | This configuration item allows Link Pass Through to be enabled(1) or disabled(2). Link Passthrough causes loss of link on one side of a media converter to be p… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.31 | Columncrmfe100RmtAutoCross | read-write | mandatory | On certain devices, it is possible for hardware to automatically correct errors in cable selection, making the distinction between a 'straight through' cable a… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.32 | Columncrmfe100RmtTPActivity | read-only | mandatory | Twisted Pair Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be n… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.33 | Columncrmfe100RmtFiberActivity | read-only | mandatory | Fiber Activity. Some versions of the CRMFE100 do not support the reporting of interface activity. The value of this variable for such a device will be notAppli… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.34 | Columncrmfe100RmtConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.35 | Columncrmfe100RmtFarEndFault | read-write | mandatory | Far End Fault configuration of this device. Far End Fault causes the fiber transmitter to generate a Far End Fault pattern upon the loss of a receiver signal d… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.36 | Columncrmfe100RmtLoopback | read-write | mandatory | When Remote Loopback is enabled, all packets sent out from the local fiber interface are reflected back by the remote converter rather than being passed out th… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.37 | Columncrmfe100RmtNetworkMode | read-only | mandatory | Read-only indicator for High Speed Token Ring jumper configuration. If the variable reads tokenRing(1), then the converter is jumpered for High Speed Token Rin… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.38 | Columncrmfe100RmtUpTime | read-write | mandatory | Time since the last reboot in Time Ticks (hundredths of seconds). If the value 0 is written to this variable, the timer is reset. No other write value is accep… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.39 | Columncrmfe100TxFxBwa | read-write | mandatory | This variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the ne… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.40 | Columncrmfe100FxTxBwa | read-write | mandatory | This variable allows the control of bandwidth allocation. The value of this variable is entered in Kilobytes per Second, and is automatically rounded to the ne… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.41 | Columncrmfe100TxBytesH | read-write | mandatory | These variables measure the traffic (in Bytes) received by the two interfaces of the converter (and therefore transmitted by the opposite interface). 'Tx' refe… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.42 | Columncrmfe100TxBytesL | read-write | mandatory | See the DESCRIPTION for cfmfe100TxBytesH(42) above. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.43 | Columncrmfe100FxBytesH | read-write | mandatory | See the DESCRIPTION for cfmfe100TxBytesH(42) above. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.44 | Columncrmfe100FxBytesL | read-write | mandatory | See the DESCRIPTION for cfmfe100TxBytesH(42) above. |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.45 | Columncrmfe100MscRxBytes | read-write | mandatory | This variable measures the traffic (in Bytes) received and transmitted by the Management Subchannel within the Fiber interface. 'Management Subchannel' refers … |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.46 | Columncrmfe100MscTxBytes | read-write | mandatory | This variable measures the traffic (in Bytes) received and transmitted by the Management Subchannel within the Fiber interface. 'Management Subchannel' refers … |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.47 | Columncrmfe100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.48 | Columncrmfe100MbTxFxBwa | read-write | mandatory | This variable allows the control of bandwidth allocation. The value of this variable is entered in Megabits per Second, and is automatically rounded to the nea… |
| 1.3.6.1.4.1.868.2.4.1.2.2.24.1.49 | Columncrmfe100MbFxTxBwa | read-write | mandatory | This variable allows the control of bandwidth allocation. The value of this variable is entered in Megabits per Second, and is automatically rounded to the nea… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25 | Tablecrs2f100Table | not-accessible | mandatory | Sparse table containing one entry for each CRS2F100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1 | Rowcrs2f100Entry | not-accessible | mandatory | Status and configuration entries for a single CRS2F100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.1 | Columncrs2f100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.2 | Columncrs2f100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.3 | Columncrs2f100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.4 | Columncrs2f100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.5 | Columncrs2f100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.6 | Columncrs2f100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.7 | Columncrs2f100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.8 | Columncrs2f100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.9 | Columncrs2f100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.10 | Columncrs2f100Fault | read-only | mandatory | Value is yes(1) when FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.11 | Columncrs2f100FirmwareRevision | read-only | mandatory | The Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can discover the revisions on these… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.12 | Columncrs2f100Loopback | read-write | mandatory | Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflecte… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.13 | Columncrs2f100DCE | read-only | mandatory | An indication of whether this device is attached to a DCE (a modem) or a DTE (a terminal or computer). |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.14 | Columncrs2f100CopperActivity | read-only | mandatory | The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise. |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.15 | Columncrs2f100ConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.16 | Columncrs2f100RmtDetected | read-only | mandatory | Has the value yes(1) if management communcations have been established with a remote media device. |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.17 | Columncrs2f100RmtLoopback | read-write | mandatory | Loopback is a testing aid available on several different products. When Loopback is enabled on an interface, all data that is sent to the interface is reflecte… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.18 | Columncrs2f100RmtDCE | read-only | mandatory | This variable describes the status of a remotely managed device. This is an indicator of whether this device is attached to a DCE (a modem) or a DTE (a termina… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.19 | Columncrs2f100RmtCopperActivity | read-only | mandatory | The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise. When n… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.20 | Columncrs2f100RmtConfigMode | read-only | mandatory | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all config… |
| 1.3.6.1.4.1.868.2.4.1.2.2.25.1.21 | Columncrs2f100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.26 | Tablecrs4f100Table | not-accessible | mandatory | Sparse table containing one entry for each CRS4F100 in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1 | Rowcrs4f100Entry | not-accessible | mandatory | Status and configuration entries for a single CRS4F100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.1 | Columncrs4f100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.2 | Columncrs4f100SlotIndex | read-only | mandatory | The slot in which the device is installed |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.3 | Columncrs4f100Groups | read-write | mandatory | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent… |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.4 | Columncrs4f100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.5 | Columncrs4f100CfgMatch | read-only | mandatory | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.6 | Columncrs4f100SerialNumber | read-only | mandatory | The serial number of this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.7 | Columncrs4f100ConnA | read-only | mandatory | The style of Fiber connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.8 | Columncrs4f100ConnB | read-only | mandatory | The style of Copper connector built into this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.9 | Columncrs4f100FiberLink | read-only | mandatory | Status of Fiber Link for this device |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.10 | Columncrs4f100Fault | read-only | mandatory | Value is yes(1) when FiberLink has value linkDown(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.11 | Columncrs4f100FirmwareRevision | read-only | mandatory | The Firmware Revision MIB Variable reports the revision of software running on the processor on this particular device. You can discover the revisions on these… |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.12 | Columncrs4f100CopperActivity | read-only | mandatory | The activity indicator has the value yes(1) when the hardware has recently detected network traffic on the associated network port, and no(2) otherwise. |
| 1.3.6.1.4.1.868.2.4.1.2.2.26.1.13 | Columncrs4f100CacheClean | read-only | mandatory | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2)… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27 | Tablecmefg100Table | not-accessible | mandatory | Generated CMEFG100 MIB Version 041110a |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1 | Rowcmefg100Entry | not-accessible | mandatory | Status and configuration entries for a single CMEFG100 |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.1 | Columncmefg100SubDeviceIndex | read-only | mandatory | If the name of a particular MIB variable does not end in 'Tbl', then it uses the placeholder value '1' in the subdevice index column. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.2 | Columncmefg100BiaIndex | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.3 | Columncmefg100SlotIndex | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.4 | Columncmefg100Groups | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.5 | Columncmefg100MRevision | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.6 | Columncmefg100CfgMatch | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.7 | Columncmefg100ImcLocEnable | read-write | mandatory | Enable periodic upload of local Interface MIB Counters from CMEFG100 to Agent. cmefg100ImcxxxTbl subdevice 1=local tp, subdevice 2=local fiber. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.8 | Columncmefg100ImcLocReset | read-write | mandatory | set to reset(1) to clear all local cmefg100Imc counters. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.9 | Columncmefg100ImcRmtEnable | read-write | mandatory | Enable periodic upload of remote Interface MIB Counters from CMEFG100 to Agent. cmefg100ImcxxxTbl subdevice 3=remote tp, subdevice 4=remote fiber. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.10 | Columncmefg100ImcRmtReset | read-write | mandatory | set to reset(1) to clear all remote cmefg100Imc counters. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.11 | Columncmefg100ImcRxAlignmentErrorsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.12 | Columncmefg100ImcRxBroadcastPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.13 | Columncmefg100ImcRxDropPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.14 | Columncmefg100ImcRxExcessSizeDiscTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.15 | Columncmefg100ImcRxFCSErrorsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.16 | Columncmefg100ImcRxFragmentsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.17 | Columncmefg100ImcRxGoodOctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.18 | Columncmefg100ImcRxGoodOctetsWrapTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.19 | Columncmefg100ImcRxJabbersTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.20 | Columncmefg100ImcRxMulticastPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.21 | Columncmefg100ImcRxOctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.22 | Columncmefg100ImcRxOctetsWrapTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.23 | Columncmefg100ImcRxOversizePktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.24 | Columncmefg100ImcRxPausePktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.25 | Columncmefg100ImcRxPkts1024to1522OctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.26 | Columncmefg100ImcRxPkts128to255OctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.27 | Columncmefg100ImcRxPkts256to511OctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.28 | Columncmefg100ImcRxPkts512to1023OctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.29 | Columncmefg100ImcRxPkts64OctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.30 | Columncmefg100ImcRxPkts65to127OctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.31 | Columncmefg100ImcRxQosOctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.32 | Columncmefg100ImcRxQosOctetsWrapTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.33 | Columncmefg100ImcRxQosPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.34 | Columncmefg100ImcRxSAChangesTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.35 | Columncmefg100ImcRxSymbolErrorTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.36 | Columncmefg100ImcRxUndersizePktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.37 | Columncmefg100ImcRxUnicastPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.38 | Columncmefg100ImcTxBroadcastPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.39 | Columncmefg100ImcTxCollisionsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.40 | Columncmefg100ImcTxDeferredTransmitTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.41 | Columncmefg100ImcTxDropPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.42 | Columncmefg100ImcTxExcessiveCollisionTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.43 | Columncmefg100ImcTxFrameInDiscTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.44 | Columncmefg100ImcTxLateCollisionTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.45 | Columncmefg100ImcTxMulticastPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.46 | Columncmefg100ImcTxMultipleCollisionTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.47 | Columncmefg100ImcTxOctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.48 | Columncmefg100ImcTxOctetsWrapTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.49 | Columncmefg100ImcTxPausePktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.50 | Columncmefg100ImcTxQosOctetsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.51 | Columncmefg100ImcTxQosOctetsWrapTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.52 | Columncmefg100ImcTxQosPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.53 | Columncmefg100ImcTxSingleCollisionTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.54 | Columncmefg100ImcTxUnicastPktsTbl | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.55 | Columncmefg100LadCacheCmd | read-write | mandatory | All variables starting with cmefg100Lad relate to the Learned MAC Address Database. Due to the large size of the LAD database and the limited memory within the… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.56 | Columncmefg100LadCacheState | read-write | mandatory | This variable shows the current state of the Agent's cache buffer with respect to the Learned Address Database. A value of 'ready' means that the cache buffer … |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.57 | Columncmefg100LadEditCmd | read-write | mandatory | Setting this var to 'write' causes LadEditMac, LadEditPort, and LadEditVid to be written (insert/overwrite as required) to the LAD. Setting this var to 'delete… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.58 | Columncmefg100LadEditMac | read-write | mandatory | A plain-text representation of a MAC address to be used the next time cmefg100LadEditCmd is set to write or delete. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.59 | Columncmefg100LadEditPort | read-write | mandatory | A port to be used the next time cmefg100LadEditCmd is set to write. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.60 | Columncmefg100LadEditVid | read-write | mandatory | A VLAN Id to be used the next time cmefg100LadEditCmd is set to write. Not valid when cmefg100VlanEnable is disabled(2) |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.61 | Columncmefg100LadEntries | read-only | mandatory | A count of the number of entries currently in the LAD Cache. See also cmefg100LadCacheState. If a LAD cache-filling transfer is in progress, this variable can … |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.62 | Columncmefg100LadMacTbl | read-only | mandatory | An Ethernet MAC address in the LAD table. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.63 | Columncmefg100LadPortTbl | read-only | mandatory | A port in the LAD table. Drop means 'forward to neither port' The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.64 | Columncmefg100LadStaticTbl | read-only | mandatory | An indication of whether the indexed entry in the LAD is static or dynamic. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEnt… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.65 | Columncmefg100LadVidTbl | read-only | mandatory | A VLAN Id in the LAD table. The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100LadEntries. If cmefg100LadEntries is 0 (either because… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.66 | Columncmefg100LocColdstart | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.67 | Columncmefg100LocDmiRxPower | read-only | mandatory | DMI: Diagnostic Monitoring Interface for fiber transceivers |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.68 | Columncmefg100LocDmiRxPowerAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.69 | Columncmefg100LocDmiTemp | read-only | mandatory | In tenths of degrees C |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.70 | Columncmefg100LocDmiTempAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.71 | Columncmefg100LocDmiTxBiasAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.72 | Columncmefg100LocDmiTxBiasCurrent | read-only | mandatory | In microamperes |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.73 | Columncmefg100LocDmiTxPower | read-only | mandatory | In microwatts |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.74 | Columncmefg100LocDmiTxPowerAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.75 | Columncmefg100LocFiberAdv1000FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.76 | Columncmefg100LocFiberAdv1000HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.77 | Columncmefg100LocFiberAutoNegot | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.78 | Columncmefg100LocFiberConnA | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.79 | Columncmefg100LocFiberDuplex | read-write | mandatory | Read-only values 3..5 are returned when autonegotiation is enabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.80 | Columncmefg100LocFiberLink | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.81 | Columncmefg100LocFiberPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.82 | Columncmefg100LocFiberQosPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.83 | Columncmefg100LocFiberSacEnable | read-write | mandatory | Enable/disable traps for Source Address Change |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.84 | Columncmefg100LocFiberSacStatus | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.85 | Columncmefg100LocFirmwareRevision | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.86 | Columncmefg100LocFpgaRev | read-only | mandatory | Field-Programmable Gate Array revision |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.87 | Columncmefg100LocFxTxBwaKb | read-write | mandatory | FX to TX bandwidth allocation, in Kbps |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.88 | Columncmefg100LocFxTxBwaMb | read-write | mandatory | FX to TX bandwidth allocation, in Mbps |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.89 | Columncmefg100LocOamActiveMode | read-only | mandatory | OAM: Operation, Administration, and Maintenance |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.90 | Columncmefg100LocOamAdminControl | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.91 | Columncmefg100LocOamConfigRevision | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.92 | Columncmefg100LocOamControlInUnknownOpcodes | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.93 | Columncmefg100LocOamCriticalEvent | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.94 | Columncmefg100LocOamDuplicateEventNotificationRx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.95 | Columncmefg100LocOamFramesLostDueToOamError | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.96 | Columncmefg100LocOamInformationRx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.97 | Columncmefg100LocOamInformationTx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.98 | Columncmefg100LocOamLastGasp | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.99 | Columncmefg100LocOamLinkEvents | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.100 | Columncmefg100LocOamLinkFault | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.101 | Columncmefg100LocOamLocDteDisc | read-only | mandatory | discovery state |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.102 | Columncmefg100LocOamLoopbackControlRx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.103 | Columncmefg100LocOamLoopbackControlTx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.104 | Columncmefg100LocOamMacAddress | read-only | mandatory | The MAC address of the OAM entity. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.105 | Columncmefg100LocOamMaxOamPduSize | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.106 | Columncmefg100LocOamMultiplexorState | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.107 | Columncmefg100LocOamOperStatus | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.108 | Columncmefg100LocOamOrgSpecificRx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.109 | Columncmefg100LocOamOrgSpecificTx | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.110 | Columncmefg100LocOamParserState | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.111 | Columncmefg100LocOamRmtDteDisc | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.112 | Columncmefg100LocOamRmtLoopback | read-only | mandatory | Indicates whether or not local has support to allow remote to initiate remote loopback mode. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.113 | Columncmefg100LocOamUnidirectional | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.114 | Columncmefg100LocOamVarRetrieval | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.115 | Columncmefg100LocSelfTestFailed | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.116 | Columncmefg100LocSerialNumber | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.117 | Columncmefg100LocTpAdv1000FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.118 | Columncmefg100LocTpAdv1000HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.119 | Columncmefg100LocTpAdv100FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.120 | Columncmefg100LocTpAdv100HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.121 | Columncmefg100LocTpAdv10FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.122 | Columncmefg100LocTpAdv10HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.123 | Columncmefg100LocTpAutoNegot | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.124 | Columncmefg100LocTpConnB | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.125 | Columncmefg100LocTpCross | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.126 | Columncmefg100LocTpDuplex | read-write | mandatory | Read-only values 3..5 are returned when autonegotiation is enabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.127 | Columncmefg100LocTpLink | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.128 | Columncmefg100LocTpPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.129 | Columncmefg100LocTpQosPause | read-write | mandatory | QOS: Quality of Service |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.130 | Columncmefg100LocTpSacEnable | read-write | mandatory | Enable/disable traps for Source Address Change |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.131 | Columncmefg100LocTpSacStatus | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.132 | Columncmefg100LocTpSpeed | read-write | mandatory | Read-only values 3..6 are returned when autonegotiation is enabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.133 | Columncmefg100LocTxFxBwaKb | read-write | mandatory | TX to FX bandwidth allocation, in Kbps |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.134 | Columncmefg100LocTxFxBwaMb | read-write | mandatory | TX to FX bandwidth allocation, in Mbps |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.135 | Columncmefg100LocUptime | read-write | mandatory | Write with 0 to reset. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.136 | Columncmefg100QosHqWeight | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.137 | Columncmefg100QosLqWeight | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.138 | Columncmefg100QosPriority | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.139 | Columncmefg100RmtColdStart | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.140 | Columncmefg100RmtDetected | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.141 | Columncmefg100RmtDmiRxPower | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.142 | Columncmefg100RmtDmiRxPowerAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.143 | Columncmefg100RmtDmiTemp | read-only | mandatory | In tenths of degrees C |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.144 | Columncmefg100RmtDmiTempAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.145 | Columncmefg100RmtDmiTxBiasAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.146 | Columncmefg100RmtDmiTxBiasCurrent | read-only | mandatory | In microamperes |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.147 | Columncmefg100RmtDmiTxPower | read-only | mandatory | In microwatts |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.148 | Columncmefg100RmtDmiTxPowerAlarm | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.149 | Columncmefg100RmtFactoryReset | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.150 | Columncmefg100RmtFiberAutoNegot | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.151 | Columncmefg100RmtFiberLink | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.152 | Columncmefg100RmtFiberPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.153 | Columncmefg100RmtFiberQosPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.154 | Columncmefg100RmtFirmwareRevision | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.155 | Columncmefg100RmtFpgaRev | read-only | mandatory | Field-Programmable Gate Array revision |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.156 | Columncmefg100RmtOamActiveMode | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.157 | Columncmefg100RmtOamCriticalEvent | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.158 | Columncmefg100RmtOamLastGasp | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.159 | Columncmefg100RmtOamLinkEvents | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.160 | Columncmefg100RmtOamLinkFault | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.161 | Columncmefg100RmtOamLocDteDisc | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.162 | Columncmefg100RmtOamPeerConfigRevision | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.163 | Columncmefg100RmtOamPeerMacAddress | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.164 | Columncmefg100RmtOamPeerMaxOamPduSize | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.165 | Columncmefg100RmtOamPeerMultiplexorState | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.166 | Columncmefg100RmtOamPeerParserState | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.167 | Columncmefg100RmtOamPeerVendorInfo | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.168 | Columncmefg100RmtOamPeerVendorOui | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.169 | Columncmefg100RmtOamRmtDteDisc | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.170 | Columncmefg100RmtOamRmtLoopback | read-write | mandatory | Initiates remote loopback mode if the remote supports it. See RmtOamPeerParserState for status information |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.171 | Columncmefg100RmtOamUnidirectional | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.172 | Columncmefg100RmtOamVarRetrieval | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.173 | Columncmefg100RmtSelfTestFailed | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.174 | Columncmefg100RmtSerialNumber | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.175 | Columncmefg100RmtTpAdv1000FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.176 | Columncmefg100RmtTpAdv1000HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.177 | Columncmefg100RmtTpAdv100FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.178 | Columncmefg100RmtTpAdv100HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.179 | Columncmefg100RmtTpAdv10FDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.180 | Columncmefg100RmtTpAdv10HDX | read-write | mandatory | Read-only value notApplicable returned when autonegotiation is disabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.181 | Columncmefg100RmtTpAutoNegot | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.182 | Columncmefg100RmtTpCross | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.183 | Columncmefg100RmtTpDuplex | read-write | mandatory | Read-only values 3..5 are returned when autonegotiation is enabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.184 | Columncmefg100RmtTpLink | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.185 | Columncmefg100RmtTpPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.186 | Columncmefg100RmtTpQosPause | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.187 | Columncmefg100RmtTpSpeed | read-write | mandatory | Read-only values 3..6 are returned when autonegotiation is enabled |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.188 | Columncmefg100RmtUptime | read-write | mandatory | Write with 0 to reset. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.189 | Columncmefg100VlanCacheCmd | read-write | mandatory | All variables starting with cmefg100Lad relate to 802.1Q VLAN controls. Setting this var to loadCache commands the agent to upload the VLAN table from the devi… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.190 | Columncmefg100VlanCacheState | read-write | mandatory | The agent discards the VLAN table shortly after uploading it to prevent the reporting of outdated information. This variable shows the current state of the cac… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.191 | Columncmefg100VlanEditCmd | read-write | mandatory | Setting this var to write causes VlanEditFwdFiber, VlanEditFwdTp, VlanEditUntagFiber, VlanEditUntagTp, and VlanEditVid to be written to the VLAN tablei (i.e. i… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.192 | Columncmefg100VlanEditFwdFiber | read-only | mandatory | A fiber egress rule to be acted upon by VlanEditCmd |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.193 | Columncmefg100VlanEditFwdTp | read-only | mandatory | A twisted pair egress rule to be acted upon by VlanEditCmd |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.194 | Columncmefg100VlanEditUntagFiber | read-only | mandatory | A fiber untag rule to be acted upon by VlanEditCmd |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.195 | Columncmefg100VlanEditUntagTp | read-only | mandatory | A twisted pair untag rule to be acted upon by VlanEditCmd |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.196 | Columncmefg100VlanEditVid | read-write | mandatory | A VLAN Id to be acted upon by VlanEditCmd |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.197 | Columncmefg100VlanEnable | read-write | mandatory | Enable/disable for 802.1Q VLAN tag processing. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.198 | Columncmefg100VlanEntries | read-only | mandatory | A count of the number of entries currently in the VLAN table cache. See also VlanCacheState. If a VLAN cache-filling transfer is in progress, this variable can… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.199 | Columncmefg100VlanFiberDefaultPri | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.200 | Columncmefg100VlanFiberDefaultVid | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.201 | Columncmefg100VlanFiberInUntaggedDrop | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.202 | Columncmefg100VlanFwdFiberTbl | read-only | mandatory | Indicates whether packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) are forwarded or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.203 | Columncmefg100VlanFwdTpTbl | read-only | mandatory | Indicates whether packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDeviceIndex) are forwarded or… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.204 | Columncmefg100VlanIngressVidHitNoMem | read-write | mandatory | Ingress violation - port from which frame originates is not a member of the VLAN indicated by the frame's tag |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.205 | Columncmefg100VlanIngressVidMiss | read-write | mandatory | Ingress violation - the VLAN indicated by the frame's tag is undefined in the VLAN table. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.206 | Columncmefg100VlanPriMapTbl | read-write | mandatory | A table containing new priority values for priority remapping. The SubDeviceIndex is 'original priority', range 0..7. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.207 | Columncmefg100VlanPriTagCtrl | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.208 | Columncmefg100VlanSetFailed | read-only | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.209 | Columncmefg100VlanTagIn | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.210 | Columncmefg100VlanTpDefaultPri | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.211 | Columncmefg100VlanTpDefaultVid | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.212 | Columncmefg100VlanTpInUntaggedDrop | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.213 | Columncmefg100VlanUntagFiberTbl | read-only | mandatory | Indicates whether VLAN Ids are stripped from packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDe… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.214 | Columncmefg100VlanUntagTpTbl | read-only | mandatory | Indicates whether VLAN Ids are stripped from packets with the VLAN Id specified by the corresponding cmefg100VlanVidTbl entry (i.e. the one with the same SubDe… |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.215 | Columncmefg100VlanVidTagCtrl | read-write | mandatory | |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.216 | Columncmefg100VlanVidTbl | read-only | mandatory | The SubDeviceIndex is an arbitrary integer sequence number, range 1..cmefg100VlanEntries. |
| 1.3.6.1.4.1.868.2.4.1.2.2.27.1.217 | Columncmefg100CacheClean | read-write | mandatory | And all of the MIB variables lived happily ever after. The End. |
| 1.3.6.1.4.1.868.2.4.2 | Nodebackplane | |||
| 1.3.6.1.4.1.868.2.4.2.1 | Nodemcc16 | |||
| 1.3.6.1.4.1.868.2.4.2.1.1 | Nodemcc16Common | |||
| 1.3.6.1.4.1.868.2.4.2.1.1.1 | Scalarmcc16ComHwReset | read-write | mandatory | Save configuration to FLASH and perform a hardware reset |
| 1.3.6.1.4.1.868.2.4.2.1.1.2 | Scalarmcc16ComMgmtHwRev | read-only | mandatory | The management h/w board revision. |
| 1.3.6.1.4.1.868.2.4.2.1.1.3 | Scalarmcc16ComMgmtSwRev | read-only | mandatory | The downloadable management s/w code revision. |
| 1.3.6.1.4.1.868.2.4.2.1.1.4 | Scalarmcc16ComIpAddr | read-write | mandatory | The IP address of the management interface. |
| 1.3.6.1.4.1.868.2.4.2.1.1.5 | Scalarmcc16ComNetMask | read-write | mandatory | The subnet mask associated with the IP address of the management interface. The value of the mask is an IP address with all the network bits set to 1 and all t… |
| 1.3.6.1.4.1.868.2.4.2.1.1.6 | Scalarmcc16ComGateway | read-write | mandatory | The managment interface's default gateway. |
| 1.3.6.1.4.1.868.2.4.2.1.1.7 | Scalarmcc16ComPS1Power | read-only | mandatory | On if power supply 1 is installed and powered |
| 1.3.6.1.4.1.868.2.4.2.1.1.8 | Scalarmcc16ComPS1InUse | read-only | mandatory | On if power supply 1 is currently active |
| 1.3.6.1.4.1.868.2.4.2.1.1.9 | Scalarmcc16ComPS2Power | read-only | mandatory | On if power supply 2 is installed and powered |
| 1.3.6.1.4.1.868.2.4.2.1.1.10 | Scalarmcc16ComPS2InUse | read-only | mandatory | On if power supply 2 is currently active |
| 1.3.6.1.4.1.868.2.4.2.1.1.11 | Scalarmcc16ComNotes | read-write | mandatory | Enduser-defined text notes |
| 1.3.6.1.4.1.868.2.4.2.1.2 | Nodemcc16Ver1 | |||
| 1.3.6.1.4.1.868.2.4.2.1.2.1 | Tablemcc16SlotTable | not-accessible | mandatory | One table entry per slot in the media converter chassis. Value of entry is type of device in the slot, or a value indicating that the slot is empty. |
| 1.3.6.1.4.1.868.2.4.2.1.2.1.1 | Rowmcc16SlotEntry | not-accessible | mandatory | The type of device inserted in a single chassis slot |
| 1.3.6.1.4.1.868.2.4.2.1.2.1.1.1 | Columnmcc16Index | read-only | mandatory | The index of a slot in a media converter chassis |
| 1.3.6.1.4.1.868.2.4.2.1.2.1.1.2 | Columnmcc16DeviceType | read-only | mandatory | The object ID of the device in the a slot |
| 1.3.6.1.4.1.868.2.4.2.2 | Nodecps | |||
| 1.3.6.1.4.1.868.2.4.2.2.1 | NodecpsCabSummary | |||
| 1.3.6.1.4.1.868.2.4.2.2.1.1 | TablecpsCabinetTable | not-accessible | mandatory | Sparse table containing one entry for each Cabinet in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.1.1.1 | RowcpsCabinetEntry | not-accessible | mandatory | Status and Configuration entries for a single Cabinet. |
| 1.3.6.1.4.1.868.2.4.2.2.1.1.1.1 | ColumncpsCabinetBiaIndex | read-only | mandatory | The serial number (BIA) of the Cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.1.1.1.2 | ColumncpsCabinetModel | read-only | mandatory | The model number of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.1.1.1.3 | ColumncpsCabinetDescription | read-write | mandatory | User defined text description of the cabinet. This description is a mirror of the ones that can be found under cpsCabDetail. |
| 1.3.6.1.4.1.868.2.4.2.2.1.1.1.4 | ColumncpsCabinetSequence | read-only | mandatory | An arbitrary sequence number assigned to the cabinet by the agent for the use of the Focal Point application. Cabinets are sorted by BiaIndex in the table, and… |
| 1.3.6.1.4.1.868.2.4.2.2.2 | NodecpsCabDetail | |||
| 1.3.6.1.4.1.868.2.4.2.2.2.1 | TablecpsMc1800Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMC1800 in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1 | RowcpsMc1800Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMC1800 |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.1 | ColumncpsMc1800BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.2 | ColumncpsMc1800Description | read-only | mandatory | User defined text description of the cabinet. A mirror of cpsCabinetDescription. |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.3 | ColumncpsMc1800PSPower1 | read-only | mandatory | Power status, first power supply slot. Value is on(1) when the supply is capable of supplying power. |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.4 | ColumncpsMc1800PSInUse1 | read-only | mandatory | Power status, first power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.5 | ColumncpsMc1800PSPower2 | read-only | mandatory | Power status, second power supply slot. Value is on(1) when the supply is capable of supplying power. |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.6 | ColumncpsMc1800PSInUse2 | read-only | mandatory | Power status, second power supply slot. Value is yes(1) when the power is selected to supply power to the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.1.1.7 | ColumncpsMc1800MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.2.2.2.2 | TablecpsMc1300Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMC1300 in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1 | RowcpsMc1300Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMC1300 |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.1 | ColumncpsMc1300BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.2 | ColumncpsMc1300Description | read-only | mandatory | User defined text description of the cabinet. A mirror of cpsCabinetDescription. |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.3 | ColumncpsMc1300PSPower1 | read-only | mandatory | Power status, first power supply slot. Value is on(1) when the supply is capable of supplying power. |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.4 | ColumncpsMc1300PSInUse1 | read-only | mandatory | For future expansion. At the time of this writing, the CPSMC1300 did not accept any power supplies capable of supporting a master/slave relationship, meaning t… |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.5 | ColumncpsMc1300PSPower2 | read-only | mandatory | Power status, second power supply slot. Value is on(1) when the supply is capable of supplying power. |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.6 | ColumncpsMc1300PSInUse2 | read-only | mandatory | For future expansion. At the time of this writing, the CPSMC1300 did not accept any power supplies capable of supporting a master/slave relationship, meaning t… |
| 1.3.6.1.4.1.868.2.4.2.2.2.2.1.7 | ColumncpsMc1300MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.2.2.2.3 | TablecpsMc0200Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMC0200 in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.2.3.1 | RowcpsMc0200Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMC0200 |
| 1.3.6.1.4.1.868.2.4.2.2.2.3.1.1 | ColumncpsMc0200BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.3.1.2 | ColumncpsMc0200Description | read-only | mandatory | User defined text description of the cabinet. A mirror of cpsCabinetDescription. |
| 1.3.6.1.4.1.868.2.4.2.2.2.3.1.3 | ColumncpsMc0200MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.2.2.2.4 | TablecpsMc1900Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMC1900 in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.2.4.1 | RowcpsMc1900Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMC1900 |
| 1.3.6.1.4.1.868.2.4.2.2.2.4.1.1 | ColumncpsMc1900BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.4.1.2 | ColumncpsMc1900Description | read-only | mandatory | User defined text description of the cabinet. A mirror of cpsCabinetDescription. |
| 1.3.6.1.4.1.868.2.4.2.2.2.4.1.3 | ColumncpsMc1900MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.2.2.2.5 | Tablesmacf100Table | not-accessible | mandatory | Sparse table containing one entry for each SMACF100 in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1 | Rowsmacf100Entry | not-accessible | mandatory | Status and configuration entries for a single SMACF100 |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.1 | Columnsmacf100BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.2 | Columnsmacf100Description | read-only | mandatory | User defined text description of the cabinet. A mirror of cpsCabinetDescription. |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.3 | Columnsmacf100MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.4 | Columnsmacf100SpanningTree | read-write | mandatory | This variable allows the agent to enable or disable Spanning Tree if it is supported. Not all versions of the hardware support Spanning Tree. |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.5 | Columnsmacf100ResetCounters | read-write | mandatory | When this variable is set to reset(1), all counters for all ports are reset to zero. |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.6 | Columnsmacf100SelfTest | read-write | mandatory | When this variable is set to selfTest(1), the cabinet will perform a self test. |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.7 | Columnsmacf100QosEnable | read-write | mandatory | This variable allows Quality of Service functions to be enabled or disabled. This includes the processing of 802.1p tags (See smacf100QosHPThreshold(8), smacf1… |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.8 | Columnsmacf100QosHPThreshold | read-write | mandatory | When an incoming 802.1p priority tag value is greater than or equal to this value (from 0 to 7), the incoming packet will be classified as high-priority. Ignor… |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.9 | Columnsmacf100QosLqWeight | read-write | mandatory | A value between 1 and 15 indicating the number of packets that should be processed from the low-priority queue before attention is turned to the high-priority … |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.10 | Columnsmacf100QosHqWeight | read-write | mandatory | A value between 1 and 15 indicating the number of packets that should be processed from the high-priority queue before attention is turned to the low-priority … |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.11 | Columnsmacf100SNMPModuleInstalled | read-only | mandatory | When this variable is set to yes(1), a management module is installed in this particular SMACF100 cabinet. |
| 1.3.6.1.4.1.868.2.4.2.2.2.5.1.12 | Columnsmacf100AgingTimer | read-write | mandatory | This configuration varible allows the MAC address aging timer to be adjusted. When an automatically discovered MAC address has not been heard from (i.e. no pac… |
| 1.3.6.1.4.1.868.2.4.2.2.2.6 | TablecpsMc0800Table | not-accessible | mandatory | Sparse table containing one entry for each CPSMC0800 in the stack, indexed by cabinet serial number. |
| 1.3.6.1.4.1.868.2.4.2.2.2.6.1 | RowcpsMc0800Entry | not-accessible | mandatory | Status and configuration entries for a single CPSMC0800 |
| 1.3.6.1.4.1.868.2.4.2.2.2.6.1.1 | ColumncpsMc0800BiaIndex | read-only | mandatory | The serial number (BIA) of the cabinet |
| 1.3.6.1.4.1.868.2.4.2.2.2.6.1.2 | ColumncpsMc0800Description | read-only | mandatory | User defined text description of the cabinet. A mirror of cpsCabinetDescription. |
| 1.3.6.1.4.1.868.2.4.2.2.2.6.1.3 | ColumncpsMc0800MRevision | read-only | mandatory | The marketing revision of this device |
| 1.3.6.1.4.1.868.2.4.2.2.3 | NodecpsAgent | |||
| 1.3.6.1.4.1.868.2.4.2.2.3.1 | ScalarcpsGroupCtrl | read-write | mandatory | This string is used to select one or more groups of devices to receive mass configuration operations. When cpsGroupCtrl.0 is null, SNMP operations are performe… |
| 1.3.6.1.4.1.868.2.4.2.2.3.2 | TablecpsSlotPwrTable | not-accessible | mandatory | Sparse table containing one power control entry for each slot in the stack, indexed by cabinet serial number and slot. |
| 1.3.6.1.4.1.868.2.4.2.2.3.2.1 | RowcpsSlotPwrEntry | not-accessible | mandatory | The power on/off control for a single Point System slot. |
| 1.3.6.1.4.1.868.2.4.2.2.3.2.1.1 | ColumncpsSlotPwrBiaIndex | read-only | mandatory | The cabinet serial number (BIA) of the slot |
| 1.3.6.1.4.1.868.2.4.2.2.3.2.1.2 | ColumncpsSlotPwrSlotIndex | read-only | mandatory | The slot number of the slot |
| 1.3.6.1.4.1.868.2.4.2.2.3.2.1.3 | ColumncpsSlotPwrState | read-write | mandatory | The power control for the slot. When off(2), no power is supplied to the slot. If examined, the slot will appear empty. |
| 1.3.6.1.4.1.868.2.4.2.2.3.3 | ScalarcpsIsPrimary | read-write | mandatory | Indicates whether or not this Management Module is the primary Management Module in the stack. This variable contains the same information as the cpsmm100IsPri… |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| CpsConnector | INTEGER { rj-45(10), stmm(11), stsm(12), scmm(13), scsm(14), scsmlh(15), scsmelh(16), scsmlhlw(17), mtrjmm(18), lc(19), bnc(20), stsmlh(21), stsmelh(22), scmm1300(23), stmm1300(24), mtrjsm(25), serial26(26), stmmlh(27), scsmsh(28), scsimplex(29), bncdual(30), db9rsxxx(31), termblock(32), rj11(33), sc40km(34), sc125km(35) } | ||
| MacAddress | OCTET STRING (SIZE (6)) |