OIDNameAccessStatusDescription
1.3.6.1.4.1.81.32Nodemeritage
1.3.6.1.4.1.81.32.1NodemeritageBase
1.3.6.1.4.1.81.32.1.1ScalarmeritageBaseLEDsread-onlymandatorySummary of the hub LEDs. The coding of each LED is defined in meritageLedColour Number of bits per LED, currently 8 (1st byte) Number of LEDs, currently 8 (2nd…
1.3.6.1.4.1.81.32.1.2ScalarmeritageBaseTemperatureExceedread-onlymandatoryFault condition indicating that the temperature exceeded 70 degrees in at least one of the modules in the hub.
1.3.6.1.4.1.81.32.1.3ScalarmeritageBaseXswitchConfigurationread-onlymandatoryThe value of this attribute shows whether the two horizontal Xswitches are connected internally to form a single 14-slots-wide Xswitch in the Meritage, or not.
1.3.6.1.4.1.81.32.1.4ScalarmeritageBaseFaultMaskread-onlymandatoryEach bit of this item describes a fault situation in the Meritage hub. bit 1: meritageBaseFanActivityStatus.1 = failed (2), bit 2: meritageBaseFanActivityStatu…
1.3.6.1.4.1.81.32.1.5TablemeritageBaseFanTablenot-accessiblemandatoryTable of attributes for Fan units in the Meritage.
1.3.6.1.4.1.81.32.1.5.1RowmeritageBaseFanEntrynot-accessiblemandatoryAn entry in the table, containing attributes for a single Fan unit in the Meritage.
1.3.6.1.4.1.81.32.1.5.1.1ColumnmeritageBaseFanIdread-onlymandatoryFan index for identifying the Fan in the Meritage 1-left, 2-right.
1.3.6.1.4.1.81.32.1.5.1.2ColumnmeritageBaseFanActivityStatusread-onlymandatoryThis attribute defines the status of the Fan.
1.3.6.1.4.1.81.32.1.6TablemeritageBasePSUTablenot-accessiblemandatoryTable of configuration attributes for the Power Supply Units.
1.3.6.1.4.1.81.32.1.6.1RowmeritageBasePSUEntrynot-accessiblemandatoryAn entry in the table, containing information for a single Power Supply Unit.
1.3.6.1.4.1.81.32.1.6.1.1ColumnmeritageBasePSUIdread-onlymandatoryIndex identifying the PSU.1-left, 2-middle, 3-right.
1.3.6.1.4.1.81.32.1.6.1.2ColumnmeritageBasePSUTyperead-onlymandatoryThis attribute indicates the PSU type.
1.3.6.1.4.1.81.32.1.6.1.3ColumnmeritageBasePSUHWVersionread-onlymandatoryHardware version of the PSU. Stored in ASCII format : first Byte - hardware major version number Second Byte - hardware minor version number (Configuration Sym…
1.3.6.1.4.1.81.32.1.6.1.4ColumnmeritageBasePSURatedPowerread-onlymandatoryThis attribute indicates the rated power of the PSU in Watts.
1.3.6.1.4.1.81.32.1.6.1.5ColumnmeritageBasePSUActivityStatusread-onlymandatoryThis attribute defines the status of the PSU: active(1) - indicates that the PSU supplies power to the chassis. failed(2) - indicates PSU failure none(3) - ind…
1.3.6.1.4.1.81.32.1.7ScalarmeritageBaseUpBckplnConfigurationread-onlymandatoryDefines whether the Upper Backplane is constructed as a single domain (full), as a dual domain (split) or not installed. The hardware supports 2 bits for this …
1.3.6.1.4.1.81.32.1.8ScalarmeritageBaseUpBckplnConfigurationSymbolread-onlymandatoryDefines the Configuration Symbol of the Upper Backplane X.Y - where X & Y are integers: 1st byte (X) - Major version number 2nd byte - '.' 3rd byte (Y) - minor…
1.3.6.1.4.1.81.32.2NodemeritageMSPV
1.3.6.1.4.1.81.32.2.1ScalarmeritageMSPVBackupStatusread-onlymandatoryThis attribute defines the status of the backup M-SPV module in the Meritage: dormant (1) - indicates that the backup M-SPV is dormant and works ok. failed (2)…
1.3.6.1.4.1.81.32.2.2ScalarmeritageMSPVMainPositionread-onlymandatoryThis attribute defines the position of the main M-SPV module in the Meritage: MSPV1 (1) - indicates that the main M-SPV is the one on the left slot MSPV2 (2) -…
1.3.6.1.4.1.81.32.3NodemeritageGroup
1.3.6.1.4.1.81.32.3.1TablemeritageGroupTablenot-accessiblemandatoryA table containing information about each group in the hub.
1.3.6.1.4.1.81.32.3.1.1RowmeritageGroupEntrynot-accessiblemandatoryAn entry containing information about a particular group in the hub.
1.3.6.1.4.1.81.32.3.1.1.1ColumnmeritageGroupIndexread-onlymandatoryIndex into this table, by group number.
1.3.6.1.4.1.81.32.3.1.1.2ColumnmeritageGroupTempExceedread-onlymandatoryFault condition indicating that temperature exceeded the threshold on the module.
1.3.6.1.4.1.81.32.3.1.1.3ColumnmeritageGroupLEDsMapread-onlymandatoryThe status of all the Group LEDs in the form of a BIT Map. The coding of each LED is defined in MeritageLedColour. The structure of this item: Number of bits p…
1.3.6.1.4.1.81.32.4NodemeritageClock
1.3.6.1.4.1.81.32.4.1ScalarmeritageClockAdminStatusread-writemandatoryenable or disable the clock sync daughter board. When disabled, the M-SPS will use its own internal clock.
1.3.6.1.4.1.81.32.4.2ScalarmeritageClockResetread-writemandatorySetting the value of this attribute to ON causes a reset only to the Clock Sync daughter board and not to the M-SPS.
1.3.6.1.4.1.81.32.4.3ScalarmeritageClockWTRread-writemandatoryThe value in seconds of Wait Time to Restore. The time the M-SPS software will wait before restoring a healthy higher priority timing source as the sync source…
1.3.6.1.4.1.81.32.4.4ScalarmeritageClockStatusread-onlymandatoryThe status of the Clock Sync daughter board: Locked - locked to the input timing source for more then 8 seconds. Holdover - Trying to simulate a clock it was p…
1.3.6.1.4.1.81.32.4.5ScalarmeritageClockCurrentSourceread-onlymandatoryThe current clock source being used. This is the outcome of the status of the sources and the priority between the sources. possible values are: ATM A, ATM B, …
1.3.6.1.4.1.81.32.5NodemeritageClockSource
1.3.6.1.4.1.81.32.5.1TablemeritageClockSourceTablenot-accessiblemandatoryA table containing information about each clock source in the hub.
1.3.6.1.4.1.81.32.5.1.1RowmeritageClockSourceEntrynot-accessiblemandatoryAn entry containing information about a particular clock source in the hub.
1.3.6.1.4.1.81.32.5.1.1.1ColumnmeritageClockSourceIndexread-onlymandatoryIndex into this table, by clock source number 1-4. 1 - ATM A 2 - ATM B 3 - SYNC A 4 - SYNC B
1.3.6.1.4.1.81.32.5.1.1.2ColumnmeritageClockSourceStatusread-onlymandatoryThe status of the source port ok - link ok los - loss of signal. failed - the source may have a link, but the M-SPS has failed 4 times to lock to it. The sourc…
1.3.6.1.4.1.81.32.5.1.1.3ColumnmeritageClockSourcePriorityread-writemandatoryThe priority of the source port 0 - disabled 1 - lowest 4 - highest
1.3.6.1.4.1.81.32.5.1.1.4ColumnmeritageClockSourceConfigPortread-writemandatoryThe port assigned to drive the Clock Source. In the format X.Y - where X & Y are integers: 1st byte (X) - Slot number 2nd byte - (.) 3rd byte (Y) - Port number…
1.3.6.1.4.1.81.32.5.1.1.5ColumnmeritageClockSourceFramingread-writemandatoryThe framing mode for the SYNC A SYNC B ports. Sources ATM A and ATM will reply with notSupported (255). For M-SPS/ER and EB, the values 1 and 2 are relevant. F…