MICROSEMI-PDSINE-MIB
64 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC1155-SMI | enterprises |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7428 | IdentitypolPowerOverLan | |||
| 1.3.6.1.4.1.7428.1 | Nodeproducts | |||
| 1.3.6.1.4.1.7428.1.1 | Nodedescription | |||
| 1.3.6.1.4.1.7428.1.1.1 | NodesysObjectID | |||
| 1.3.6.1.4.1.7428.1.1.1.1 | NodemidspanUnknown | |||
| 1.3.6.1.4.1.7428.1.1.1.2 | Nodemidspan6portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.3 | Nodemidspan6portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.4 | Nodemidspan12portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.5 | Nodemidspan12portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.6 | Nodemidspan24portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.7 | Nodemidspan24portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.8 | Nodemidspan48portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.9 | Nodemidspan48portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.10 | Nodemidspan6portHPAC | |||
| 1.3.6.1.4.1.7428.1.1.1.11 | Nodemidspan6portHPACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.12 | Nodemidspan12portHPAC | |||
| 1.3.6.1.4.1.7428.1.1.1.13 | Nodemidspan12portHPACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.14 | NodemidspanGigabit6portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.15 | NodemidspanGigabit12portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.16 | NodemidspanGigabit24portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.17 | NodemidspanHiPoEGigabit6portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.18 | NodemidspanHiPoEGigabit12portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.19 | NodemidspanHiPoEGigabit24portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.20 | NodemidspanHiPoEATGigabit6portAC | |||
| 1.3.6.1.4.1.7428.1.1.1.21 | NodemidspanHiPoEATGigabit12portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.22 | NodemidspanHiPoEATGigabit24portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.23 | Nodemidspan4PairATGigabit6portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.24 | Nodemidspan4PairATGigabit12portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.25 | NodemidspanHiPoEATGigabit6portDC | |||
| 1.3.6.1.4.1.7428.1.1.1.26 | NodemidspanHiPoEATGigabit12portDC | |||
| 1.3.6.1.4.1.7428.1.1.1.27 | NodemidspanHiPoEATGigabit24portDC | |||
| 1.3.6.1.4.1.7428.1.1.1.28 | Nodemidspan4PairATGigabit24portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.29 | NodemidspanEEPoEGigabit24portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.30 | NodemidspanPoHGigabit6portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.31 | NodemidspanPoHGigabit12portACDC | |||
| 1.3.6.1.4.1.7428.1.1.1.32 | NodemidspanPoHGigabit24portACDC | |||
| 1.3.6.1.4.1.7428.1.2 | NodepseDevice | |||
| 1.3.6.1.4.1.7428.1.2.1 | NodeportObjects | |||
| 1.3.6.1.4.1.7428.1.2.1.1 | TableportTable | not-accessible | current | A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be impleme… |
| 1.3.6.1.4.1.7428.1.2.1.1.1 | RowportEntry | not-accessible | current | A set of objects that display and control the power characteristics of a power Ethernet PSE port. |
| 1.3.6.1.4.1.7428.1.2.1.1.1.1 | ColumnportGroupIndex | not-accessible | current | This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and … |
| 1.3.6.1.4.1.7428.1.2.1.1.1.2 | ColumnportIndex | not-accessible | current | This variable uniquely identifies the power Ethernet PSE port within group portGroupIndex to which the power Ethernet PSE entry is connected. |
| 1.3.6.1.4.1.7428.1.2.1.1.1.3 | ColumnportConsumptionPower | read-only | current | A read-only value indicates the measured usage power expressed in Watts for a specific port |
| 1.3.6.1.4.1.7428.1.2.1.1.1.4 | ColumnportMaxPower | read-write | current | Read/Write maximum power consumption that PD device may consume in Watts NOTE: 1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt 2. For … |
| 1.3.6.1.4.1.7428.1.2.1.1.1.5 | ColumnportType | read-write | current | Enable/Disable Four-pair/EEPoE PoE Read : Applicable to all Midspan series Write: Applicable only to 95xxG/55xxG Midspan series twopair (1) Two-pair PoE port c… |
| 1.3.6.1.4.1.7428.1.2.2 | NodemainObjects | |||
| 1.3.6.1.4.1.7428.1.2.2.1 | TablemainPseTable | not-accessible | current | A table of objects that display and control attributes of the main PSE device. |
| 1.3.6.1.4.1.7428.1.2.2.1.1 | RowmainPseEntry | not-accessible | current | A set of objects that display and control the Main PSE device. |
| 1.3.6.1.4.1.7428.1.2.2.1.1.1 | ColumnmainGroupIndex | not-accessible | current | This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be … |
| 1.3.6.1.4.1.7428.1.2.2.1.1.2 | ColumnmainVoltage | read-only | current | Power Supply Voltage in Volt. |
| 1.3.6.1.4.1.7428.1.2.2.1.1.3 | ColumnmainDetectionMethod | read-write | current | Read/Write PD device detection method (802.3af / 802.3af+Legacy). |
| 1.3.6.1.4.1.7428.1.2.2.1.1.4 | ColumnmainPowerUsageBudget | read-write | current | Allow external SNMP manager to limit maximum power that all PD's may consume Whenever total power consumption exceeds maximum power, Midspan may turn off autom… |
| 1.3.6.1.4.1.7428.1.2.2.1.1.5 | ColumnmainPSEMaxPower | read-only | current | Maximum power that Midspan can provide (Watt), after including power budget percentage limitation. Example: Midspan maximum power without power limit = 860Watt… |
| 1.3.6.1.4.1.7428.1.2.2.1.1.6 | ColumnhighPowerLegacyPDSupport | read-write | current | Applicable only for Midspan 90xxG series enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device). disable(2) - Power only 802.3at … |
| 1.3.6.1.4.1.7428.1.2.2.1.1.7 | ColumnhighPowerExtendedPortPower | read-write | current | Applicable only for Midspan 90xxG/55xxG series enable (1) - Extend maximum power to PD device beyond 802.3at specification. disable(2) - Maximum power to PD de… |
| 1.3.6.1.4.1.7428.1.2.2.1.1.8 | ColumnpowerBackupStatus | read-only | current | Applicable only for Midspan 90xxG/95xxG/55xxG series standalone - Midspan isn't connected to any power backup device powerbackupbyrps - Redundant power supply … |
| 1.3.6.1.4.1.7428.1.2.2.1.1.9 | ColumninternalPowerSourceStatus | read-only | current | Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - Internal Power Source is OK fail(2) - Internal Power Source failure |
| 1.3.6.1.4.1.7428.1.2.2.1.1.10 | ColumnexternalPowerSourceStatus | read-only | current | Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - External Power Source is OK fail(2) - External Power Source failure notsupported(3) - SNMP GET res… |
| 1.3.6.1.4.1.7428.1.2.2.1.1.11 | Columntemperature | read-only | current | Unit temperature - Applicable only for Midspan 95xxG series |
| 1.3.6.1.4.1.7428.1.2.2.1.1.12 | Columntemperatureformat | read-write | current | Unit temperature format - Applicable only for Midspan 95xxG series Celcius(1) - Report unit temperature in Celcius Fahrenheit(2) - Report unit temperature in F… |
| 1.3.6.1.4.1.7428.1.3 | NodepoeNotifications | |||
| 1.3.6.1.4.1.7428.1.3.1 | NotificationpowerBackupStatusNotification | current | Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports power backup status change, and whenever incompatible power backup source is con… | |
| 1.3.6.1.4.1.7428.1.3.2 | NotificationinternalPowerSourceStatusNotification | current | Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports internal Power Source failure | |
| 1.3.6.1.4.1.7428.1.3.3 | NotificationexternalPowerSourceStatusNotification | current | Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports external Power Source failure |