MIB Viewer

NETSCREEN-CHASSIS-MIB

24 objects
This module defines the objects that are used to monitor device status such as Battery, Fan, Power and Temperature
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.3224.21IdentitynetscreenChassisThis module defines the objects that are used to monitor device status such as Battery, Fan, Power and Temperature
1.3.6.1.4.1.3224.21.1TablensPowerTablenot-accessiblecurrentInformation describing installed power supply modules and their status
1.3.6.1.4.1.3224.21.1.1RownsPowerEntrynot-accessiblecurrentInformation describing one power supply module and its status
1.3.6.1.4.1.3224.21.1.1.1ColumnnsPowerIdread-onlycurrentA 32-bit integer uniquely identifying the power supply id. For 5400, range is 1~3, For 5200, range is 1~2
1.3.6.1.4.1.3224.21.1.1.2ColumnnsPowerStatusread-onlycurrentA 32-bit integer uniquely identifying the power supply module's status: 0. Fail 1. Good 2. Not installed
1.3.6.1.4.1.3224.21.1.1.3ColumnnsPowerDescread-onlycurrentA description for the power supply module
1.3.6.1.4.1.3224.21.2TablensFanTablenot-accessiblecurrentInformation describing the installed Fan modules and their status
1.3.6.1.4.1.3224.21.2.1RownsFanEntrynot-accessiblecurrentInformation describing one installed Fan module and its status
1.3.6.1.4.1.3224.21.2.1.1ColumnnsFanIdread-onlycurrentA 32-bit integer uniquely identifying the Fan id. At the time of this writing.
1.3.6.1.4.1.3224.21.2.1.2ColumnnsFanStatusread-onlycurrentA 32-bit integer uniquely identifying the Fan module's status: 0. Fail 1. Good
1.3.6.1.4.1.3224.21.2.1.3ColumnnsFanDescread-onlycurrentA description for the Fan module
1.3.6.1.4.1.3224.21.3ScalarsysBatteryStatusread-onlycurrentInformation describing the installed Battery and its status: 1. Good 2. Error
1.3.6.1.4.1.3224.21.4TablensTemperatureTablenot-accessiblecurrentInformation describing the temperature measured by each module
1.3.6.1.4.1.3224.21.4.1RownsTemperatureEntrynot-accessiblecurrentThe temperature measured by a module
1.3.6.1.4.1.3224.21.4.1.1ColumnnsTemperatureIdread-onlycurrentA 32-bit integer uniquely identifying temperature measured on a board or on a component e.g. CPU
1.3.6.1.4.1.3224.21.4.1.2ColumnnsTemperatureSlotIdread-onlycurrentA 32-bit integer uniquely identifying the slot where the temperature is measured.
1.3.6.1.4.1.3224.21.4.1.3ColumnnsTemperatureCurread-onlycurrentThe current temperature measured by the module, unit is Celsius
1.3.6.1.4.1.3224.21.4.1.4ColumnnsTemperatureDescread-onlycurrentA description for the module
1.3.6.1.4.1.3224.21.5TablensSlotTablenot-accessiblecurrentInformation describing the installed management and traffic processing modules and their status, built-in and internal module are also listed here.
1.3.6.1.4.1.3224.21.5.1RownsSlotEntrynot-accessiblecurrentInformation describing one installed module and its status
1.3.6.1.4.1.3224.21.5.1.1ColumnnsSlotIdread-onlycurrentA 32-bit integer uniquely identifying the slot id. The range varies on different platforms
1.3.6.1.4.1.3224.21.5.1.2ColumnnsSlotTyperead-onlycurrentA description of the installed module
1.3.6.1.4.1.3224.21.5.1.3ColumnnsSlotStatusread-onlycurrentSlot status
1.3.6.1.4.1.3224.21.5.1.4ColumnnsSlotSNread-onlycurrentSerial Number of the module