OCCAM-MLT-MIB
116 objects
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Imported Objects
| OCCAM-REG-MODULE | occamGenericMonitorModules |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6066.2.1.1.3 | IdentityoccamMltMib | This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results. | ||
| 1.3.6.1.4.1.6066.2.1.1.3.1 | NodemltTestConfig | |||
| 1.3.6.1.4.1.6066.2.1.1.3.1.1 | ScalarmltTestIdentifier | read-write | current | Selects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite… |
| 1.3.6.1.4.1.6066.2.1.1.3.1.2 | ScalarmltTestType | read-write | current | Selects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used. |
| 1.3.6.1.4.1.6066.2.1.1.3.1.3 | ScalarmltTestPort | read-write | current | Selects voice channel on which test will be run. This is a required parameter. |
| 1.3.6.1.4.1.6066.2.1.1.3.1.4 | ScalarmltDcResistanceRange | read-write | current | Selects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode). |
| 1.3.6.1.4.1.6066.2.1.1.3.1.5 | ScalarmltLoopLengthMultiplier | read-write | current | Selects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used. |
| 1.3.6.1.4.1.6066.2.1.1.3.1.6 | ScalarmltLoopDetectThreshold | read-write | current | Selects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used. |
| 1.3.6.1.4.1.6066.2.1.1.3.2 | NodemltTestStatus | |||
| 1.3.6.1.4.1.6066.2.1.1.3.2.1 | ScalarmltLastTestStatus | read-only | current | Indicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls… |
| 1.3.6.1.4.1.6066.2.1.1.3.2.2 | ScalarmltErrorText | read-only | current | Indicates the textual error in the case of an aborted test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3 | NodemltTestResults | |||
| 1.3.6.1.4.1.6066.2.1.1.3.3.1 | TablemltStatusResultsTable | not-accessible | current | This table provides result of the status test suite. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1 | RowmltStatusResultsEntry | not-accessible | current | Entry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the va… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1 | ColumnmltStatusAlarm | read-only | current | Indicates GNK and/or OTEMP alarms active when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2 | ColumnmltStatusHookState | read-only | current | Indicates line hook state when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3 | ColumnmltStatusTransversalCurrent | read-only | current | Indicates transversal current when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4 | ColumnmltStatusLongitudinalCurrent | read-only | current | Indicates Longitudinal current when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5 | ColumnmltStatusTipVoltage | read-only | current | Indicates tip voltage when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6 | ColumnmltStatusRingVoltage | read-only | current | Indicates ring voltage when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7 | ColumnmltStatusTipRingVoltage | read-only | current | Indicates tip-ring voltage when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8 | ColumnmltStatusVdd | read-only | current | Indicates Vdd when status test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2 | TablemltTestResultsTable | not-accessible | current | This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1 | RowmltTestResultsEntry | not-accessible | current | Entry holding information about results of mlt suite tests. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1 | ColumnmltTestAlarm | read-only | current | GNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuS… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2 | ColumnmltTestHookState | read-only | current | Hook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3 | ColumnmltTestVdd | read-only | current | On HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be avail… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4 | ColumnmltTestActiveModeVoltagesVdctr | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5 | ColumnmltTestActiveModeVoltagesVdctg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6 | ColumnmltTestActiveModeVoltagesVdcrg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7 | ColumnmltTestActiveModeVoltagesVactr | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. … |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8 | ColumnmltTestActiveModeVoltagesVactg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. … |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9 | ColumnmltTestActiveModeVoltagesVacrg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. … |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10 | ColumnmltTestHighImpedanceModeVoltagesVdctr | read-only | current | High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11 | ColumnmltTestHighImpedanceModeVoltagesVdctg | read-only | current | High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12 | ColumnmltTestHighImpedanceModeVoltagesVdcrg | read-only | current | High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13 | ColumnmltTestHighImpedanceModeVoltagesVactr | read-only | current | High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14 | ColumnmltTestHighImpedanceModeVoltagesVactg | read-only | current | High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15 | ColumnmltTestHighImpedanceModeVoltagesVacrg | read-only | current | High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16 | ColumnmltTestDcCurrentsItransversal | read-only | current | Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17 | ColumnmltTestDcCurrentsIlongitudinal | read-only | current | Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18 | ColumnmltTestDcCurrentsItip | read-only | current | Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19 | ColumnmltTestDcCurrentsIring | read-only | current | Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available i… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20 | ColumnmltTestCapacitanceCeqtr | read-only | current | Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21 | ColumnmltTestCapacitanceCeqtg | read-only | current | Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22 | ColumnmltTestCapacitanceCeqrg | read-only | current | Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23 | ColumnmltTestResistanceRtr | read-only | current | DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24 | ColumnmltTestResistanceRtg | read-only | current | DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25 | ColumnmltTestResistanceRrg | read-only | current | DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 | ColumnmltTestGr909HazardousPotentialTestResult | read-only | current | This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fa… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27 | ColumnmltTestGr909ForeignEmfTestResult | read-only | current | This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fa… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28 | ColumnmltTestGr909FuseTestTipFuse | read-only | obsolete | This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29 | ColumnmltTestGr909FuseTestRingFuse | read-only | obsolete | This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30 | ColumnmltTestGr909ResistiveFaultTestResult | read-only | current | This test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test w… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31 | ColumnmltTestGr909ReceiverOffhookTestResult | read-only | current | This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32 | ColumnmltTestGr909ReceiverOffhookTestResistance1 | read-only | current | This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33 | ColumnmltTestGr909ReceiverOffhookTestResistance2 | read-only | current | This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34 | ColumnmltTestGr909ReceiverOffhookTestDifference | read-only | current | This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be per… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35 | ColumnmltTestGr909RingerTestResult | read-only | current | This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 | ColumnmltTestGr909RingerTestRen | read-only | current | This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37 | ColumnmltTestErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38 | ColumnmltTestFuseTestTipFuse | read-only | current | This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39 | ColumnmltTestFuseTestRingFuse | read-only | current | This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This para… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3 | TablemltActiveModeVoltagesResultsTable | not-accessible | current | This table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1 | RowmltActiveModeVoltagesResultsEntry | not-accessible | current | Entry holding information about results of mlt active mode voltages test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1 | ColumnmltActiveModeVoltagesVdctr | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2 | ColumnmltActiveModeVoltagesVdctg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3 | ColumnmltActiveModeVoltagesVdcrg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be report… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4 | ColumnmltActiveModeVoltagesVactr | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. … |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5 | ColumnmltActiveModeVoltagesVactg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. … |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6 | ColumnmltActiveModeVoltagesVacrg | read-only | current | Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. … |
| 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7 | ColumnmltActiveModeVoltagesErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4 | TablemltHighImpedanceModeVoltagesResultsTable | not-accessible | current | This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1 | RowmltHighImpedanceModeVoltagesResultsEntry | not-accessible | current | Entry holding information about results of mlt high impedance mode voltages test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1 | ColumnmltHighImpedanceModeVoltagesVdctr | read-only | current | High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2 | ColumnmltHighImpedanceModeVoltagesVdctg | read-only | current | High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3 | ColumnmltHighImpedanceModeVoltagesVdcrg | read-only | current | High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4 | ColumnmltHighImpedanceModeVoltagesVactr | read-only | current | High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5 | ColumnmltHighImpedanceModeVoltagesVactg | read-only | current | High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6 | ColumnmltHighImpedanceModeVoltagesVacrg | read-only | current | High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent forei… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7 | ColumnmltHighImpedanceModeVoltagesErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.5 | TablemltDcResistanceResultsTable | not-accessible | current | This table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.5.1 | RowmltDcResistanceResultsEntry | not-accessible | current | Entry holding information about results of mlt DC resistance test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1 | ColumnmltDcResistanceRtr | read-only | current | DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2 | ColumnmltDcResistanceRtg | read-only | current | DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3 | ColumnmltDcResistanceRrg | read-only | current | DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4 | ColumnmltDcResistanceErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.6 | TablemltCapacitanceResultsTable | not-accessible | current | This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.6.1 | RowmltCapacitanceResultsEntry | not-accessible | current | Entry holding information about results of mlt capacitance test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1 | ColumnmltCapacitanceCeqtr | read-only | current | Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2 | ColumnmltCapacitanceCeqtg | read-only | current | Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3 | ColumnmltCapacitanceCeqrg | read-only | current | Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacita… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4 | ColumnmltCapacitanceErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.7 | TablemltLoopDetectResultsTable | not-accessible | current | This table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value cou… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.7.1 | RowmltLoopDetectResultsEntry | not-accessible | current | Entry holding information about results of mlt loop detect test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1 | ColumnmltLoopDetectLoopCapacitance | read-only | current | Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshol… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2 | ColumnmltLoopDetectDetectionThreshold | read-only | current | Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection thresho… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3 | ColumnmltLoopDetectLoopDetected | read-only | current | Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection thresho… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4 | ColumnmltLoopDetectErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8 | TablemltLoopLengthResultsTable | not-accessible | current | This table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value cou… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1 | RowmltLoopLengthResultsEntry | not-accessible | current | Entry holding information about results of mlt loop length test. |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1 | ColumnmltLoopLengthCapacitanceFactor | read-only | current | Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2 | ColumnmltLoopLengthLoopCapacitance | read-only | current | Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3 | ColumnmltLoopLengthLoopLength | read-only | current | Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4 | ColumnmltLoopLengthUncompensatedLoopCapacitance | read-only | current | Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5 | ColumnmltLoopLengthUncompensatedLoopLength | read-only | current | Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length m… |
| 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6 | ColumnmltLoopLengthErrors | read-only | current | Indicates GNK and/or OTEMP alarms active when test was run. |
| 1.3.6.1.4.1.6066.2.1.1.3.4 | NodemltTestNotifications | |||
| 1.3.6.1.4.1.6066.2.1.1.3.4.1 | NotificationmltTestCompletedNotification | current | This notification is sent to the requesting host when the requested mlt test has completed. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| MltTestHookState | INTEGER { onhook ( 1 ) , offhook ( 2 ), notAvailable ( 3 ) } | current | An mlt test hook state value. |
| MltTestIdentifier | INTEGER { statusSuite ( 1 ) , mltSuite ( 2 ) , activeModeVoltages ( 3 ) , highImpedanceModeVoltages ( 4 ) , dcResistance ( 5 ) , capacitance ( 6 ) , loopDetect ( 7 ) , loopLength ( 8 ) } | current | An mlt test selection value. |
| MltTestPassFail | INTEGER { pass ( 1 ) , fail ( 2 ), notAvailable ( 3 ) } | current | An mlt test pass/fail value. |
| MltTestRingerResult | INTEGER { pass ( 1 ) , fail ( 2 ), notAvailable ( 3 ), low ( 4 ) } | current | An mlt ringer test result value. |
| MltTestStatus | INTEGER { none ( 1 ) , mltBusy ( 2 ), complete ( 3 ) , portInUse ( 4 ) , inProgress ( 5 ), mltError ( 6 ), mltNotResponding ( 7 ) } | current | An indication of test status: none = no test has been requested. mltbusy = another port is currently being tested. complete = the last requested test has completed. portInUse = the last requested port is in use, the tes… |
| MltTestType | INTEGER { request ( 1 ) , force ( 2 ) } | current | A selection value for requesting or forcing a test. A requested test will only run if the port is not in use. A forced test will immediately shut the port and run the test. |
| MltTestYesNo | INTEGER { yes ( 1 ) , no ( 2 ), notAvailable ( 3 ) } | current | An mlt test pass/fail value. |