MIB Viewer

OPTIX-L2-LAG-MIB

64 objects
This mib specifies the port configuration information of L2 lag
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.4.50.19IdentityoptixL2LagThis mib specifies the port configuration information of L2 lag
1.3.6.1.2.1.10.4.50.19.1NodeoptixL2LagGroup
1.3.6.1.2.1.10.4.50.19.1.1TableoptixL2LagLinkAggreTablenot-accessiblecurrentThis table describes the L2 LAG configurations.
1.3.6.1.2.1.10.4.50.19.1.1.1RowoptixL2LagLinkAggreEntrynot-accessiblecurrentThis entry describes the L2 LAG configurations.
1.3.6.1.2.1.10.4.50.19.1.1.1.1ColumnoptixL2LagLinkAggreIdnot-accessiblecurrentThis object indicates the L2 LAG ID.
1.3.6.1.2.1.10.4.50.19.1.1.1.2ColumnoptixL2LagLinkAggreNameread-createcurrentThis object indicates the L2 LAG name.
1.3.6.1.2.1.10.4.50.19.1.1.1.3ColumnoptixL2LagLinkAggreGroupSysPriread-createcurrentThis object indicates the system priority of the L2 LAG. Value range: 0 to 65535. The default value is 32768.
1.3.6.1.2.1.10.4.50.19.1.1.1.4ColumnoptixL2LagLinkAggreGroupTyperead-createcurrentThis object indicates the L2 LAG type. 0: manual, 1: static
1.3.6.1.2.1.10.4.50.19.1.1.1.5ColumnoptixL2LagLinkAggreRvtModeread-createcurrentThis object indicates the revetive mode of the L2 LAG. 0: disable, 1: enable
1.3.6.1.2.1.10.4.50.19.1.1.1.6ColumnoptixL2LagLinkAggreLoadTyperead-createcurrentThis object indicates the load-sharing type of the L2 LAG. 0: share, 1: noShare
1.3.6.1.2.1.10.4.50.19.1.1.1.7ColumnoptixL2LagLinkAggreLoadAlgread-onlycurrentThis object indicates the load-sharingalgorithm of the L2 LAG. 0: auto, 1: srcMac, 2: dstMac, 3: srcDstMac, 4: srcIp, 5: dstIp, 6: srcDstIp, 7: srcPort, 8: dst…
1.3.6.1.2.1.10.4.50.19.1.1.1.8ColumnoptixL2LagLinkAggreMainBidread-createcurrentThis object indicates the master slot ID of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.9ColumnoptixL2LagLinkAggreMainSubIdread-createcurrentThis object indicates the master subboard ID of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.10ColumnoptixL2LagLinkAggreMainPidread-createcurrentThis object indicates the master port number of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.11ColumnoptixL2LagLinkAggrMainPortPriread-onlycurrentThis object indicates the master port priority of the L2 LAG. Value range: 0 to 65535. The default value is 32768.
1.3.6.1.2.1.10.4.50.19.1.1.1.12ColumnoptixL2LagLinkAggreWtrTimeread-createcurrentThis object indicates the WTR time of the L2 LAG. Value range: 0 to 30 (unit: minute). The default value is 10.
1.3.6.1.2.1.10.4.50.19.1.1.1.13ColumnoptixL2LagLinkAggreSdEnread-createcurrentThis object indicates the enable status of the LAG switching due to air interface bit errors. 0: disable, 1: enable
1.3.6.1.2.1.10.4.50.19.1.1.1.14ColumnoptixL2LagLinkAggrSlvPortlistread-createcurrentThis object indicates the slave port list of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.15ColumnoptixL2LagLinkAggrWorkPortlistread-onlycurrentThis object indicates the working port list of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.16ColumnoptixL2LagLinkAggreLDProtocolread-createcurrentThis object indicates the LD protocol of the L2 LAG. 0: null, 1: 3ah
1.3.6.1.2.1.10.4.50.19.1.1.1.17ColumnoptixL2LagLinkAggrePeriodread-createcurrentThis object indicates the master port priority of the L2 LAG. 0: long, 1: short
1.3.6.1.2.1.10.4.50.19.1.1.1.18ColumnoptixL2LagLinkAggreMinActLinkthread-createcurrentThis object indicates the minimum number of active links of the L2 LAG. Value range: 1 to the total number of main and slave ports in a LAG group. The default …
1.3.6.1.2.1.10.4.50.19.1.1.1.19ColumnoptixL2LagLinkAggreSlavePortNumread-createcurrentThis parameter indicates the number of slave ports in the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.20ColumnoptixL2LagLinkAggreSlavePortInforead-onlycurrentThis object indicates the slave port info of active links of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.21ColumnoptixL2LagLinkAggreWtrTimeExread-createcurrentThis parameter indicates the WTR of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.1.1.255ColumnoptixL2LagLinkAggreRowStatusread-createcurrentThis object indicates the row status of the L2 LAG.
1.3.6.1.2.1.10.4.50.19.1.2TableoptixL2LagLinkAggrePortTablenot-accessiblecurrentThis table describes the L2 LAG port configurations.
1.3.6.1.2.1.10.4.50.19.1.2.1RowoptixL2LagLinkAggrePortEntrynot-accessiblecurrentThis entry describes the L2 LAG port configurations.
1.3.6.1.2.1.10.4.50.19.1.2.1.1ColumnoptixL2LagLinkAggreSlvBidnot-accessiblecurrentThis object indicates the slot ID of the L2 LAG port.
1.3.6.1.2.1.10.4.50.19.1.2.1.2ColumnoptixL2LagLinkAggreSlvSbidnot-accessiblecurrentThis object indicates the subboard ID of the L2 LAG port.
1.3.6.1.2.1.10.4.50.19.1.2.1.3ColumnoptixL2LagLinkAggreSlvPortIdnot-accessiblecurrentThis object indicates the logical port number of the L2 LAG port.
1.3.6.1.2.1.10.4.50.19.1.2.1.4ColumnoptixL2LagLinkAggreInfoLocalSysIdread-onlycurrentThis object indicates the local system ID of the L2 LAG. System priority+MAC address
1.3.6.1.2.1.10.4.50.19.1.2.1.5ColumnoptixL2LagLinkAggreInfoLocalPidread-onlycurrentThis object indicates the logical port number of the L2 LAG localport.
1.3.6.1.2.1.10.4.50.19.1.2.1.6ColumnoptixL2LagLinkAggreInfoLocalPortPriread-onlycurrentThis object indicates the priority of the L2 LAG local port. Value range: 0 to 65535. The default value is 32768.
1.3.6.1.2.1.10.4.50.19.1.2.1.7ColumnoptixL2LagLinkAggreInfoLocalPortOpKeyread-onlycurrentThis object indicates the operation key of the L2 LAG local port. The default value is 0.
1.3.6.1.2.1.10.4.50.19.1.2.1.8ColumnoptixL2LagLinkAggreInfoLocalPortLacpFlagread-onlycurrentThis object indicates the LACP flag of the L2 LAG local port. The default value is 125. Packets are sent in a long period.
1.3.6.1.2.1.10.4.50.19.1.2.1.9ColumnoptixL2LagLinkAggrInfoRemoteSysIdread-onlycurrentThis object indicates the remote system ID of the L2 LAG. System priority+MAC address
1.3.6.1.2.1.10.4.50.19.1.2.1.10ColumnoptixL2LagLinkAggrInfoRemotePidread-onlycurrentThis object indicates the logical port number of the L2 LAG remote port.
1.3.6.1.2.1.10.4.50.19.1.2.1.11ColumnoptixL2LagLinkAggrInfoRemotePortPriread-onlycurrentThis object indicates the priority of the L2 LAG remote port. Value range: 0 to 65535. The default value is 32768.
1.3.6.1.2.1.10.4.50.19.1.2.1.12ColumnoptixL2LagLinkAggrInfoRemoteOpKeyread-onlycurrentThis object indicates the operation key of the L2 LAG remote port. The default value is 0.
1.3.6.1.2.1.10.4.50.19.1.2.1.13ColumnoptixL2LagLinkAggrInfoRemotePortLacpFlagread-onlycurrentThis object indicates the LACP status of the L2 LAG remote port. The default value is 125. Packets are sent in a long period.
1.3.6.1.2.1.10.4.50.19.1.2.1.14ColumnoptixL2LagLinkAggreRcvPduread-onlycurrentThis object indicates the packets received by the L2 LAG. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.15ColumnoptixL2LagLinkAggreRcvIllPduread-onlycurrentThis object indicates the error packets received by the L2 LAG. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.16ColumnoptixL2LagLinkAggreSendPduread-onlycurrentThis object indicates the packets transmitted by the L2 LAG. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.17ColumnoptixL2LagLinkAggreRcvMarkPduread-onlycurrentThis object indicates the marked packets received by the L2 LAG. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.18ColumnoptixL2LagLinkAggreRcvIllMarkPduread-onlycurrentThis object indicates the marked error packets received by the L2 LAG. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.19ColumnoptixL2LagLinkAggreSendMarkPduread-onlycurrentThis object indicates the marked packets transmitted by the L2 LAG. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.20ColumnoptixL2LagLinkAggrePortPriread-createcurrentThis object indicates the priority of the L2 LAG slave port. Value range: 0 to 0xffffffff.
1.3.6.1.2.1.10.4.50.19.1.2.1.21ColumnoptixL2LagLinkAggrePortSelectedread-onlycurrentThis object indicates the selected status of the L2 LAG port. 0: selected, 1: standby, 2: unselected
1.3.6.1.2.1.10.4.50.19.1.2.1.22ColumnoptixL2LagLinkAggrePortInuseread-onlycurrentThis object indicates the used status of the L2 LAG port. 0: false, 1: true
1.3.6.1.2.1.10.4.50.19.1.2.1.23ColumnoptixL2LagLinkAggrePortRefread-onlycurrentThis object indicates the referenced status of the L2 LAG port. 0: false, 1: true
1.3.6.1.2.1.10.4.50.19.1.2.1.24ColumnoptixL2LagLinkAggreLagIdread-createcurrentThis entry describes the L2 LAG configurations. Value range: 1 to 16.
1.3.6.1.2.1.10.4.50.19.1.2.1.25ColumnoptixL2LagLinkAggrePdutyperead-createcurrentThis object indicates the cleartype of packets by the L2 LAG. 1: lacpdurcv, 2: lacpdurcvill, 3: lacpdusend, 4: markerpdurcv, 5: markerpdurcvill, 6: markerrsppd…
1.3.6.1.2.1.10.4.50.19.1.2.1.255ColumnoptixL2LagLinkAggrePortRowStatusread-createcurrentThis object indicates the row status of the L2 LAG logical port.
1.3.6.1.2.1.10.4.50.19.1.3TableoptixL2LagPortFsmTablenot-accessiblecurrentThis table describes the L2 LAG history state configurations.
1.3.6.1.2.1.10.4.50.19.1.3.1RowoptixL2LagPortFsmEntrynot-accessiblecurrentThis entry describes the L2 LAG history state configurations.
1.3.6.1.2.1.10.4.50.19.1.3.1.1ColumnoptixL2LagPortFsmTypenot-accessiblecurrentThis object indicates the type of the L2 LAG Finite State Machine. 1: rx, 2: ptx, 3: mux, 4: actor, 5: partner
1.3.6.1.2.1.10.4.50.19.1.3.1.2ColumnoptixL2LagPortFsmInfoNumread-onlycurrentThis object indicates the number of the L2 LAG Finite State Machine. Value range: 1 to 10.
1.3.6.1.2.1.10.4.50.19.1.3.1.3ColumnoptixL2LagPortFsmCauseread-onlycurrentThis object indicates the transferential reason of the L2 LAG Finite State Machine. '&' is used to separate multiple records. For example, PORTENLACPEN &am…
1.3.6.1.2.1.10.4.50.19.1.3.1.4ColumnoptixL2LagPortFsmLacpStateread-onlycurrentThis object indicates the state of the L2 LAG Finite State Machine. '&' is used to separate multiple records. For example, MUXWAITING & MUXDETACHED.
1.3.6.1.2.1.10.4.50.19.1.3.1.5ColumnoptixL2LagPortFsmTimeStampread-onlycurrentThis object indicates the timestamp of the L2 LAG Finite State Machine.
1.3.6.1.2.1.10.4.50.19.1.3.1.6ColumnoptixL2LagPortFsmTimeCentiSecread-onlycurrentThis object indicates the CentiSec of the L2 LAG Finite State Machine.
1.3.6.1.2.1.10.4.50.19.2NodeoptixL2LagLoadGroup
1.3.6.1.2.1.10.4.50.19.2.1ScalaroptixL2LagTtllagloadalgread-writecurrentThis object indicates the TTL Load alg of the L2 LAG.