MIB Viewer
MIB Viewer Desktop New

OPTIX-PKT-SYS-SYN-MIB

34 objects
This MIB describes configurations ofsystem clock source management.
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.4.50.35IdentityoptixpktSYSsynThis MIB describes configurations ofsystem clock source management.
1.3.6.1.2.1.10.4.50.35.1NodeoptixpktSYSsynGroup
1.3.6.1.2.1.10.4.50.35.1.1TableoptixpktSYSsynTablenot-accessiblecurrentThis table contains configuration information of system clock sources.
1.3.6.1.2.1.10.4.50.35.1.1.1RowoptixpktSYSsynEntrynot-accessiblecurrentThis table contains configuration information of system clock sources.
1.3.6.1.2.1.10.4.50.35.1.1.1.1ColumnoptixpktSYSsynCurSynread-onlycurrentThis parameter specifies current SDH clock source. Value range: 0x01ff0001 to 0x06ff0006 with 0x00f00001, 0x00f00002, and 0x00f10001.
1.3.6.1.2.1.10.4.50.35.1.1.1.2ColumnoptixpktSYSCurSynS1Valueread-onlycurrentThis parameter specifies the s1 value of the current clock source. 0: qlUnknown, 2: qlPrc, 4: qlSsua, 8: qlSsub, 11: qlSec, 15: qlDnu
1.3.6.1.2.1.10.4.50.35.1.1.1.3ColumnoptixpktSYSsynPriTableCLkListread-writecurrentThis parameter specifies the list of clock source priorities.
1.3.6.1.2.1.10.4.50.35.1.1.1.4ColumnoptixpktSYSsyn24HourKeepModeread-writecurrentThis parameter specifies the 24 hour keep mode of SDH clock sources. 0: disable, 1: enable
1.3.6.1.2.1.10.4.50.35.1.1.1.5ColumnoptixpktSYSsynSwStateread-onlycurrentThis parameter specifies the switching state. 0: synAuto, 1: synMan, 2: synForce
1.3.6.1.2.1.10.4.50.35.1.1.1.6ColumnoptixpktsynProtectSynWtrTimeread-writecurrentThis parameter specifies the clock source WTR time. Value range: 0 to 12 (unit: minute).
1.3.6.1.2.1.10.4.50.35.1.1.1.7ColumnoptixpktSYSclkpllLockstateread-onlycurrentThis parameter specifies the system clock PLL lock state.
1.3.6.1.2.1.10.4.50.35.1.1.1.8ColumnoptixpktSysSynWorkModeread-onlycurrentThis parameter specifies working mode. 1: trace, 2: keep, 3: free
1.3.6.1.2.1.10.4.50.35.1.2TableoptixpktSYSsynClassTablenot-accessiblecurrentThis table contains configuration information of system clock lists.
1.3.6.1.2.1.10.4.50.35.1.2.1RowoptixpktSYSsynClassEntrynot-accessiblecurrentThis entry containing configuration information of system clock lists.
1.3.6.1.2.1.10.4.50.35.1.2.1.1ColumnoptixpktSSMExQulityread-writecurrentThis parameter specifies the SSM protocol configuration of the clock source. Value range: 0x00, 0x02, 0x04, 0x08, 0x0b, 0x0f, and 0xff.
1.3.6.1.2.1.10.4.50.35.1.2.1.2ColumnoptixpktsysSSMEnableFlagread-writecurrentThis object indicates the enable status of the SSM protocol. 1: permit, 0: forbid
1.3.6.1.2.1.10.4.50.35.1.2.1.3ColumnoptixpktSSMsynClkIdModeread-writecurrentThis object indicates the enable status of forbidding the output of SSM protocol clock ID. 1: permit, 0: forbid
1.3.6.1.2.1.10.4.50.35.1.2.1.4ColumnoptixpktSYSsynStatusread-onlycurrentThis parameter specifies the clock source status. 0: invalid, 1: valid
1.3.6.1.2.1.10.4.50.35.1.2.1.5ColumnoptixpktsynProtectEnableread-writecurrentThis parameter specifies the clock source protection enable status. 0: disable, 1: enable
1.3.6.1.2.1.10.4.50.35.1.2.1.6ColumnoptixpktsysSynSubNetread-writecurrentThis parameter specifies the subnet ID. Value range: 0 to 255.
1.3.6.1.2.1.10.4.50.35.1.2.1.7ColumnoptixpktsysSynNodeIDread-writecurrentThis parameter specifies the node ID. Value range: 0x00 to 0x0f.
1.3.6.1.2.1.10.4.50.35.1.2.1.8ColumnoptixpktsysSynS1Moderead-onlycurrentThis node represents the clock source's S1 byte value: qlUnknown(0), qlPrc(2), qlSsua(4), qlSsub(8), qlSec(11), or qlDnu(15).
1.3.6.1.2.1.10.4.50.35.1.2.1.9ColumnoptixpktsysSynSwread-writecurrentThis node indicates switching or clearing the clock source: 0-clea, 1-manual, 2-force.
1.3.6.1.2.1.10.4.50.35.1.3TableoptixpktSynGroupTablenot-accessiblecurrentConfiguration information of the system clock source group
1.3.6.1.2.1.10.4.50.35.1.3.1RowoptixpktSynGroupEntrynot-accessiblecurrentEntry to the configuration information of the system clock source group
1.3.6.1.2.1.10.4.50.35.1.3.1.1ColumnoptixpktSynBoardIDnot-accessiblecurrentSystem control board ID in a clock source group
1.3.6.1.2.1.10.4.50.35.1.3.1.2ColumnoptixpktSynGroupidnot-accessiblecurrentClock source group ID
1.3.6.1.2.1.10.4.50.35.1.3.1.3ColumnoptixpktSynGroupSysNumread-createcurrentNumber of clock sources in a clock source group
1.3.6.1.2.1.10.4.50.35.1.3.1.4ColumnoptixpktSynGroupSysListread-createcurrentClock source list
1.3.6.1.2.1.10.4.50.35.1.3.1.255ColumnoptixpktSynGroupRowStatusread-createcurrentRow status of the clock source group
1.3.6.1.2.1.10.4.50.35.2NodeoptixpktSYSsynNeGroup
1.3.6.1.2.1.10.4.50.35.2.1ScalaroptixpktSYSsynCnorvtread-writecurrentThis node describes whether the clock switching by the descending order of priorities is enabled.
1.3.6.1.2.1.10.4.50.35.2.2ScalaroptixpktSYSsynQlunknowValue1read-writecurrentThe node describes the QL_UNKNOW-represented quality level 1.
1.3.6.1.2.1.10.4.50.35.2.3ScalaroptixpktSYSsynQlunknowValue2read-writecurrentThe node describes the QL_UNKNOW-represented quality level 2.