MIB Viewer

OPTIX-PW-OAM-MIB

21 objects
This module is used to configure and manage the MPLS PW OAM. The PW OAM provides complete fault detection and identification mechanism and network performance monitoringat the PW layer. Based on the OAM check result, the equipment determines whether to trigger protection switching. The PW OAM enables quick faultdetection and identificationand service protection.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.4.50.7IdentityoptixPWOamModThis module is used to configure and manage the MPLS PW OAM. The PW OAM provides complete fault detection and identification mechanism and network performance …
1.3.6.1.2.1.10.4.50.7.1NodeoptixPWOamObject
1.3.6.1.2.1.10.4.50.7.1.1TableoptixPWOamTablenot-accessiblecurrentThistable is used to configure PW OAM attributes, including the PW OAM enable status, detection mode, CC detection mode, and SD/SF thresholds.
1.3.6.1.2.1.10.4.50.7.1.1.1RowoptixPWOamEntrynot-accessiblecurrentThisentry is used to manage PW OAM attributes.
1.3.6.1.2.1.10.4.50.7.1.1.1.1ColumnoptixPWOamIndexnot-accessiblecurrentThis object indicates the PW OAM index, ranging from 1 to 0x00ffffff.
1.3.6.1.2.1.10.4.50.7.1.1.1.2ColumnoptixPWOamEnableread-writecurrentThis object indicates whether the OAM is enabled. 1: enable 0: disable
1.3.6.1.2.1.10.4.50.7.1.1.1.3ColumnoptixPWOamCheckWayread-writecurrentThis object indicates the OAM detection mode. 1: auto 2: manual
1.3.6.1.2.1.10.4.50.7.1.1.1.4ColumnoptixPWOamCcTyperead-writecurrentThis object indicates the CC detection packet type. 1: cv (default value) 2: ffd
1.3.6.1.2.1.10.4.50.7.1.1.1.5ColumnoptixPWOamCcTimeread-writecurrentThis object indicates the CC detection packet frequency. When the packet type is cv, the frequency is an invalid value, 0xff. When the packet type is ffd, the …
1.3.6.1.2.1.10.4.50.7.1.1.1.6ColumnoptixPWOamSfread-writecurrentThis object indicates the SF threshold (packet loss rate). Valid values range from 0 to 100.
1.3.6.1.2.1.10.4.50.7.1.1.1.7ColumnoptixPWOamSdread-writecurrentThis object indicates the SD threshold (packet loss rate). Valid values range from 0 to 100.
1.3.6.1.2.1.10.4.50.7.1.1.1.8ColumnoptixPWOamPeerLsrIdread-writecurrentThis object indicates the LSR ID to receive, which is the LSR ID of the valid MPLS device. 0.0.0.0: indicates that the peer IP address of the local PW is autom…
1.3.6.1.2.1.10.4.50.7.1.1.1.9ColumnoptixPWOamPeerPwIdread-writecurrentThis object indicates the remote PW ID, which is a valid MPLS PW ID. 0: indicates that the ID of the local PW is automatically obtained.
1.3.6.1.2.1.10.4.50.7.1.1.1.10ColumnoptixPWOamStandardread-writecurrentThis object indicates the OAM protocol standard  1: 1711 2: 1731
1.3.6.1.2.1.10.4.50.7.1.2TableoptixPWOamStateTablenot-accessiblecurrentThistable is used to query the PW OAM status.
1.3.6.1.2.1.10.4.50.7.1.2.1RowoptixPWOamStateEntrynot-accessiblecurrentThisentry is used to manage the PW OAM status.
1.3.6.1.2.1.10.4.50.7.1.2.1.1ColumnoptixPWOamDirectionnot-accessiblecurrentFor bidirectional MPLS PWs, the status query is performed in two directions, local and remote ends. This object indicates the direction of the PW OAM. The stat…
1.3.6.1.2.1.10.4.50.7.1.2.1.2ColumnoptixPWOamStateread-onlycurrentThis object indicates the PW OAM status. 0: initialstate, 1: nearendavailable, 2: nearenddefectavailable, 3: nearenddefectunavailable, 4: nearendunavailable, 5…
1.3.6.1.2.1.10.4.50.7.1.2.1.3ColumnoptixPWOamDefectTyperead-onlycurrentThis object indicates the defect type of the PW OAM. 1: dserver, 2: dpeerme, 3: dlocv, 4: dttsimismatch, 5: dttsimismerge, 6: dexcess, 7: dunknown, 255: invalid
1.3.6.1.2.1.10.4.50.7.1.2.1.4ColumnoptixPWOamUnavailableTimeread-onlycurrentThis object indicates the unavailable time of the PW OAM. The time ranges from 0 to 300,000 ms. 4294967295: invalid
1.3.6.1.2.1.10.4.50.7.1.2.1.5ColumnoptixPWOamDefectPositionread-onlycurrentThis object indicates the position of the PW OAM defect: a node identified by IP address.