1.3.6.1.4.1.285Nodeolicom
1.3.6.1.4.1.285.1Nodeinfo
1.3.6.1.4.1.285.1NodeobmCallbackThis trap is sent when the device tries to place a OBM callback phonecall to phone number obmCallbackPhoneNumber. Even though the call might be repeated severa…
1.3.6.1.4.1.285.1.1ScalarinfoHardwareProductIdread-onlymandatoryA string containing the hardware product id.
1.3.6.1.4.1.285.1.2ScalarinfoHardwareVersionread-onlymandatoryA string containing the hardware version.
1.3.6.1.4.1.285.1.3ScalarinfoHardwareECOLevelread-onlymandatoryA string containing the ECO update level.
1.3.6.1.4.1.285.1.4ScalarinfoHardwareSerialNumberread-onlymandatoryA string containing the hardware serial number.
1.3.6.1.4.1.285.1.5TableinfoHardwareOptionTablenot-accessiblemandatoryA sequence of hardware options, each a string describing the appropriate option present.
1.3.6.1.4.1.285.1.5.1RowinfoHardwareOptionTableEntrynot-accessiblemandatory
1.3.6.1.4.1.285.1.5.1.1ColumninfoHardwareOptionNoread-onlymandatoryThe option number for this option.
1.3.6.1.4.1.285.1.5.1.2ColumninfoHardwareOptionread-onlymandatoryA string describing this option.
1.3.6.1.4.1.285.1.6ScalarinfoSoftwareProductIdread-onlymandatoryA string containing the software product id. Recommended format is as follows: the string consists of fixed and optional part. Fixed part contains device's sym…
1.3.6.1.4.1.285.1.7ScalarinfoSoftwareVersionread-onlymandatoryA string containing the software version. Recommended format is as follows: the string consists of fixed and optional part. Fixed part contains software versio…
1.3.6.1.4.1.285.1.8ScalarinfoSoftwareECOLevelread-onlymandatoryA string containing the ECO update level.
1.3.6.1.4.1.285.1.9TableinfoSoftwareOptionTablenot-accessiblemandatoryA sequence of software options, each a string describing the appropriate option present.
1.3.6.1.4.1.285.1.9.1RowinfoSoftwareOptionTableEntrynot-accessiblemandatory
1.3.6.1.4.1.285.1.9.1.1ColumninfoSoftwareOptionNoread-onlymandatoryThe option number for this option.
1.3.6.1.4.1.285.1.9.1.2ColumninfoSoftwareOptionread-onlymandatoryA string describing this option.
1.3.6.1.4.1.285.1.10TableinfoSoftwareMIBsTablenot-accessiblemandatoryA sequence of MIBs supported by this device.
1.3.6.1.4.1.285.1.10.1RowinfoSoftwareMIBsTableEntrynot-accessiblemandatory
1.3.6.1.4.1.285.1.10.1.1ColumninfoSoftwareMIBsNoread-onlymandatoryThe number for this MIB description entry.
1.3.6.1.4.1.285.1.10.1.2ColumninfoSoftwareMIBsObjectIDread-onlymandatoryThe unique OBJECT IDENTIFIER for this MIB description entry. Olicom specific MIBs have OBJECT IDENTIFIERs that are defined as { ocmibs N }. (See ocmibs section…
1.3.6.1.4.1.285.1.10.1.3ColumninfoSoftwareMIBsDescriptionread-onlymandatoryA string describing this MIB description entry.
1.3.6.1.4.1.285.1.11TableinfoXtraSwTablenot-accessibleoptionalThis table contains the product IDs and addtional information for the additional files included in a multichunk file.
1.3.6.1.4.1.285.1.11.1RowinfoXtraSwEntrynot-accessibleoptionalAn entry in the infoXtraSwTable.
1.3.6.1.4.1.285.1.11.1.1ColumninfoXtraSwIndexread-onlyoptionalThe entry number in the infoXtraSwTable.
1.3.6.1.4.1.285.1.11.1.2ColumninfoXtraSwFileUseread-onlyoptionalFrom the file header: The target for the SW image.
1.3.6.1.4.1.285.1.11.1.3ColumninfoXtraSwProductIdread-onlyoptionalFrom the file header: The SW product ID.
1.3.6.1.4.1.285.1.11.1.4ColumninfoXtraSwVersionread-onlyoptionalFrom the file header: The SW version.
1.3.6.1.4.1.285.1.11.1.5ColumninfoXtraSwEcoLevelread-onlyoptionalFrom the file header: The SW ECO level.
1.3.6.1.4.1.285.1.11.1.6ColumninfoXtraSwSerialNumberread-onlyoptionalFrom the file header: The SW serial number.
1.3.6.1.4.1.285.1.11.1.7ColumninfoXtraSwOptionsread-onlyoptionalFrom the file header: A bitmask of SW options.
1.3.6.1.4.1.285.1.12TableinfoModuleTablenot-accessiblemandatoryThis table describes all the HW modules in a system with multiple modules.
1.3.6.1.4.1.285.1.12.1RowinfoModuleEntrynot-accessiblemandatoryA list of information objects for a HW module.
1.3.6.1.4.1.285.1.12.1.1ColumninfoModuleIndexread-onlymandatoryThe module index of this module. This is a unique index identifying a hardware module in the switching system. The planar board of a switch box is considered a…
1.3.6.1.4.1.285.1.12.1.2ColumninfoModuleHwProductIdread-onlymandatoryA string containing the modules product id (eg. from EEPROM)
1.3.6.1.4.1.285.1.12.1.3ColumninfoModuleHwVersionread-onlymandatoryA string containing the modules version (eg. from EEPROM)
1.3.6.1.4.1.285.1.12.1.4ColumninfoModuleHwSerialNumberread-onlymandatoryA string containing the modules serial no (eg. from EEPROM)
1.3.6.1.4.1.285.1.12.1.5ColumninfoModuleBootpromVersionread-onlymandatoryA string containing the modules bootprom version. An empty string, if no bootprom is present on this module.
1.3.6.1.4.1.285.1.13TableinfoSwImageTablenot-accessiblemandatoryThis table describes all the SW images in the system.
1.3.6.1.4.1.285.1.13.1RowinfoSwImageEntrynot-accessiblemandatoryA list of information objects for SW image.
1.3.6.1.4.1.285.1.13.1.1ColumninfoSwImageModuleIndexread-onlymandatoryThe module index of the module on which the SW image reside.
1.3.6.1.4.1.285.1.13.1.2ColumninfoSwImageNoread-onlymandatoryThe SW image number, relative to the HW module.
1.3.6.1.4.1.285.1.13.1.3ColumninfoSwImageProductIdread-onlymandatoryA string containing the SW images product id. An empty string, if this image is not present or corrupted.
1.3.6.1.4.1.285.1.13.1.4ColumninfoSwImageVersionread-onlymandatoryA string containing the SW images version. An empty string, if this image is not present or corrupted.
1.3.6.1.4.1.285.1.13.1.5ColumninfoSwImageDownloadTimeread-onlymandatoryThe time when the software image was downloaded to the device. This is measured in seconds since 00:00:00 on 1 January 1970 (i.e. UNIX standard time).
1.3.6.1.4.1.285.2NodeobmCalloutThis trap is sent when the device tries to place a OBM callout phonecall to phone number obmCalloutPhoneNumber because it was triggered by the event(s) obmCall…
1.3.6.1.4.1.285.2Nodeocmibs
1.3.6.1.4.1.285.2.1NodeocmibsBridgeMIB
1.3.6.1.4.1.285.2.2NodeocmibsCauMIB
1.3.6.1.4.1.285.2.3NodeocmibsCamMIB
1.3.6.1.4.1.285.2.4NodeocmibsEhubMIB
1.3.6.1.4.1.285.2.5NodeocmibsOc8100MIB
1.3.6.1.4.1.285.2.6NodeocmibsCrossfireAtmMIB
1.3.6.1.4.1.285.2.7NodeocmibsOc8200MIB
1.3.6.1.4.1.285.2.8NodeocmibsOc8600MIB
1.3.6.1.4.1.285.2.9NodeocmibsOc84x0MIB
1.3.6.1.4.1.285.2.10NodeocmibsLanSwitchMIB
1.3.6.1.4.1.285.2.11NodeocmibsVlanMIB
1.3.6.1.4.1.285.2.12NodeocmibsSmartStatusMIB
1.3.6.1.4.1.285.2.13NodeocmibsCf871xMIB
1.3.6.1.4.1.285.2.14NodeatmUplinkMIB
1.3.6.1.4.1.285.3Nodetemporary
1.3.6.1.4.1.285.3.1NodelmpMib
1.3.6.1.4.1.285.4Nodeinet
1.3.6.1.4.1.285.4.1ScalarinetMacAddrFormread-writemandatoryThis variable controls in which form MAC addresses will be represented. The default is canonical form for ethernet products and non-cannonical for tokenring pr…
1.3.6.1.4.1.285.4.2ScalarinetEnableRwhoread-writemandatoryThis variable controls whether the device will send rhwo packets on UDP port 513. The packets include information about pseudo-users logged in. For the Olicom …
1.3.6.1.4.1.285.4.3ScalarinetEnableRIPread-writemandatoryThis variable control whether the device will process RIP (Routing Information Protocol) packets on UDP port 520 to update the IP routing table. The device wil…
1.3.6.1.4.1.285.4.4ScalarinetCommunityMaxEntriesread-onlymandatoryThe maximum number of community entries allowed in inetCommunityTable.
1.3.6.1.4.1.285.4.5TableinetCommunityTablenot-accessiblemandatoryA list of entries for each community which is authorized to access the agent. The maximum number of entries is given by inetCommunityMaxEntries.
1.3.6.1.4.1.285.4.5.1RowinetCommunityTableEntrynot-accessiblemandatoryA community entry containing objects pertaining to a network manager which is authorized to access the agent.
1.3.6.1.4.1.285.4.5.1.1ColumninetCommunityNoread-onlymandatoryThe entry number in the community table for this community.
1.3.6.1.4.1.285.4.5.1.2ColumninetCommunityNamewrite-onlymandatoryThe community name used by the management station to access the agent. An empty community name means that any request regardless of it's community name will be…
1.3.6.1.4.1.285.4.5.1.3ColumninetCommunityIPAddresswrite-onlymandatoryThe IP address of the management station authorized to access the agent. A value of 0.0.0.0 allows every IP node to use the community name.
1.3.6.1.4.1.285.4.5.1.4ColumninetCommunityAccesswrite-onlymandatoryControls the access rights of the management station.
1.3.6.1.4.1.285.4.5.1.5ColumninetCommunityDeletewrite-onlymandatorySetting this object to a non zero value, deletes the entry for this community entry.
1.3.6.1.4.1.285.4.5.1.6ColumninetCommunityIPXAddresswrite-onlymandatoryThe IPX address of the management station authorized to access the agent. A value of all zeroes allows every IPX node to use the community name.
1.3.6.1.4.1.285.4.5.1.7ColumninetCommunityTransportProtocolswrite-onlymandatoryThis variable defines which transport protocols should be expected to deliver requests for this community. If the bit-value 0x01 is set, UDP/IP is used and the…
1.3.6.1.4.1.285.4.5.1.8ColumninetCommunityMACAddresswrite-onlymandatoryThe MAC address of the management station authorized to access the agent. A value of 000000000000 allows every MAC node to use the community name.
1.3.6.1.4.1.285.4.6ScalarinetTrapMaxEntriesread-onlymandatoryThe maximum number of network manager entries allowed in inetTrapTable.
1.3.6.1.4.1.285.4.7TableinetTrapTablenot-accessiblemandatoryA list of trap entries for each network manager which receives traps from the agent. The maximum number of entries is given by trapMaxEntries.
1.3.6.1.4.1.285.4.7.1RowinetTrapTableEntrynot-accessiblemandatoryA trap entry containing objects pertaining to a network manager which receives traps from the agent.
1.3.6.1.4.1.285.4.7.1.1ColumninetTrapCommunityread-writemandatoryThe community name used in traps sent to the management station.
1.3.6.1.4.1.285.4.7.1.2ColumninetTrapDestIPAddressread-writemandatoryThe IP address of the management station to receive traps. Note a value of zero or resetting inetTrapTransportProtocols bit value 0x01 disables IP based traps …
1.3.6.1.4.1.285.4.7.1.3ColumninetTrapEventDisableMaskread-writedeprecatedNOTE: This field has been replaced by the controlTrapTable. Bitmask of disabled traps from product-specific network management agents. Each octet within the va…
1.3.6.1.4.1.285.4.7.1.4ColumninetTrapDeletewrite-onlymandatorySetting this object to a non-zero value, deletes the entry for the trap destination.
1.3.6.1.4.1.285.4.7.1.5ColumninetTrapDestUDPPortread-writemandatoryThe UDP port on the management station to receive traps. If set to 0 (zero) the default value 162 is used.
1.3.6.1.4.1.285.4.7.1.6ColumninetTrapIndexread-onlymandatoryAll entries in the inetTrapTable have a unique index, denoted by this variable.
1.3.6.1.4.1.285.4.7.1.7ColumninetTrapDestIPXAddressread-writemandatoryThe IPX address of the management station to receive traps. Note a value of zero or resetting inetTrapTransportProtocols bit value 0x02 disables IPX based trap…
1.3.6.1.4.1.285.4.7.1.8ColumninetTrapTransportProtocolsread-writemandatoryThis variable defines which transport protocols should be used to deliver TRAPs for this trap destination. If the bit-value 0x01 is set, UDP/IP is use and the …
1.3.6.1.4.1.285.4.7.1.9ColumninetTrapIPEncapsulationread-writemandatoryThis variable controls the encapsulation method used when delivering TRAPs via the UDP/IP protocol. NOTE: On TokenRing devices only snap(3) works. ON EtherNet …
1.3.6.1.4.1.285.4.7.1.10ColumninetTrapIPXEncapsulationread-writemandatoryThis variable controls the encapsulation method used when delivering TRAPs via the IPX protocol. NOTE: On TokenRing devices only ieee8022(2) and snap(3) works.
1.3.6.1.4.1.285.4.8ScalarinetDefaultIPEncapsulationread-writemandatoryThis variable controls the default encapsulation method used by this device, when transmitting via the UDP/IP protocol. This default encapsulation method is on…
1.3.6.1.4.1.285.4.9ScalarinetDefaultIPXEncapsulationread-writemandatoryThis variable controls the default encapsulation method used by this device, when transmitting via the IPX protocol. This default encapsulation method is only …
1.3.6.1.4.1.285.4.10TableinetIPAddressTablenot-accessiblemandatoryThis table contains IP addressing information for each interface.
1.3.6.1.4.1.285.4.10.1RowinetIPAddressEntrynot-accessiblemandatory
1.3.6.1.4.1.285.4.10.1.1ColumninetIPAddressIfNumberread-onlymandatoryThis number corresponds to the interface number, ifIndex, in ifTable from MIB-II.
1.3.6.1.4.1.285.4.10.1.2ColumninetIPAddressIPAddressread-writemandatoryThis is the IP address associated with the interface.
1.3.6.1.4.1.285.4.10.1.3ColumninetIPAddressNetmaskread-writemandatoryThis is the IP netmask associated with the interface. Note: Setting the netmask for one interface may change the netmask for other interfaces.
1.3.6.1.4.1.285.4.10.1.4ColumninetIPAddressDefaultGatewayread-writemandatoryThis is the IP default gateway associated with the interface. Note: Setting the default gateway for one interface may change the default gateway for other inte…
1.3.6.1.4.1.285.4.10.1.5ColumninetIPAddressEnableRwhoread-writeoptionalThis variable controls whether the device will send rhwo packets on UDP port 513 on the specified interface. The packets include information about pseudo-users…
1.3.6.1.4.1.285.4.10.1.6ColumninetIPAddressEnableRIPread-writeoptionalThis variable control whether the device will process RIP (Routing Information Protocol) packets on UDP port 520 on the specified interface to update the IP ro…
1.3.6.1.4.1.285.4.10.1.7ColumninetIPAddressIPEncapsulationread-writemandatoryThis variable controls the IP encapsulation method used on the specified interface. Choosing media-default(4) selects SNAP encapsulation on TokenRing interface…
1.3.6.1.4.1.285.4.11ScalarinetSlipBaudrateread-writeoptionalThe baud rate used by a SLIP connection.
1.3.6.1.4.1.285.4.12ScalarinetSlipParityread-writeoptionalThe transmission parity used by a SLIP connection.
1.3.6.1.4.1.285.4.13ScalarinetSlipStopbitsread-writeoptionalThe number of stop bits used by a SLIP connection.
1.3.6.1.4.1.285.4.14ScalarinetSlipModemInitread-writeoptionalA string sent to the modem to initialize it prior to establishing a SLIP connection.
1.3.6.1.4.1.285.4.15ScalarinetSlipHeaderCompressionEnabledread-writeoptionalEnable or disable compression of the SLIP headers.
1.3.6.1.4.1.285.4.16ScalarinetSlipMaxMtuSizeread-writeoptionalMaximum Transmit Unit size, that is, the maximum size of a PDU transmitted on a SLIP connection.
1.3.6.1.4.1.285.4.17ScalarinetSlipMaxMruSizeread-writeoptionalMaximum Receive Unit size, that is, the maximum acceptable size of a PDU received on a SLIP connection.
1.3.6.1.4.1.285.4.18ScalarsCallbackEnableread-writedeprecatedThis object controls whether the Olicom Out-Of-Band Management Callback sub-system should be active (enabled) or not.
1.3.6.1.4.1.285.4.19ScalarsCallbackPhoneNumberread-writedeprecatedA string containing the telephone number to be used by the callback sub-system. This string will be sent `as is' to the modem connected to the OBM communicatio…
1.3.6.1.4.1.285.4.20ScalarsCalloutEnableread-writedeprecatedThis object controls whether the Olicom Out-Of-Band Management Callout sub-system should be active (enabled) or not.
1.3.6.1.4.1.285.4.21ScalarsCalloutPhoneNumberread-writedeprecatedA string containing the telephone number to be used by the callout sub-system. This string will be sent `as is' to the modem connected to the OBM communication…
1.3.6.1.4.1.285.5Nodecontrol
1.3.6.1.4.1.285.5.1ScalarcontrolRestartwrite-onlymandatoryWriting any value other than zero to this variable causes the device program to restart.
1.3.6.1.4.1.285.5.2ScalarcontrolConfigChangeCounterread-writemandatoryThis variable contains the number of times, any part of the configuration has been changed by any of the management systems controlling this device. See the ma…
1.3.6.1.4.1.285.5.3TablecontrolTrapTablenot-accessiblemandatoryThis table contains an entry for each enterprise-specific TRAP this device is capable of sending. The only writable field in the table is the controlTrapGenera…
1.3.6.1.4.1.285.5.3.1RowcontrolTrapTableEntrynot-accessiblemandatoryA controlTrapTableEntry entry contains objects pertaining to one particular enterprise-specific TRAP.
1.3.6.1.4.1.285.5.3.1.1ColumncontrolTrapIndexread-onlymandatoryThis variable corresponds to the inetTrapIndex variable in the inetTrapTable.
1.3.6.1.4.1.285.5.3.1.2ColumncontrolTrapMIBIndexread-onlymandatoryThis variable identifies the MIB in which this TRAP is defined. The variable is the index of the entry in infoSoftwareMIBsTable that defines the MIB in questio…
1.3.6.1.4.1.285.5.3.1.3ColumncontrolTrapNumberread-onlymandatoryThis variable describes in which TRAP in the MIB subtree this TRAP is.
1.3.6.1.4.1.285.5.3.1.4ColumncontrolTrapDescriptionread-onlymandatoryThis variable describes the TRAP. This corresponds to the description field in the MIB text for this TRAP.
1.3.6.1.4.1.285.5.3.1.5ColumncontrolTrapGenerationread-writemandatoryThis variable controls whether this TRAP never(1) is generated or is always(2) generated.
1.3.6.1.4.1.285.5.4ScalarcontrolLoadProtocolread-writemandatoryThis variable defines which protocol should be used for downloading configuration and program code. Notice that a specific Olicom product will typically suppor…
1.3.6.1.4.1.285.5.5ScalarcontrolLoadFilenameread-writemandatoryIn the Load protocols where it is relevant this variable contains the name of the file to be downloaded.
1.3.6.1.4.1.285.5.6ScalarcontrolLoadServerMACAddressread-writeoptionalThis object specifies the MAC address of the Load server used for download. Only used if the Load protocol defined by the controlLoadProtocol variable needs th…
1.3.6.1.4.1.285.5.7ScalarcontrolLoadServerIPAddressread-writeoptionalThis object specifies the IP address of the Load server used for download. Only used if the Load protocol defined by the controlLoadProtocol variable needs the…
1.3.6.1.4.1.285.5.8ScalarcontrolLoadServerIPXAddressread-writeoptionalThis object specifies the IPX address of the Load server used for download. Only used if the Load protocol defined by the controlLoadProtocol variable needs th…
1.3.6.1.4.1.285.5.9ScalarcontrolLoadStartread-writemandatoryWriting any value other than zero to this variable causes a download to start. While reading, it returns the current status of transmission or last transmissio…
1.3.6.1.4.1.285.5.10ScalarcontrolTimeread-writemandatoryThe internal clock in the device. This is measured in seconds since 00:00:00 on 1 January 1970 (i.e. UNIX standard time).
1.3.6.1.4.1.285.5.11ScalarcontrolEnableRmonread-writeoptionalThis object specifies whether RMON probe is enabled or disabled. If the device does not support RMON only disabled is allowed. Setting this variable resets the…
1.3.6.1.4.1.285.5.12ScalarcontrolAutoRestartread-writeoptionalThis object specifies whether changes to certain fundamental configuration parameters (as specified for the corresponding MIB variables) shall cause the device…
1.3.6.1.4.1.285.5.13ScalarcontrolSwAdminStatusread-writeoptionalThis object controls the state of the SW images in systems where more than one image is present. In the OC-9100 the state of each image may be: empty(1) - no i…
1.3.6.1.4.1.285.5.15ScalarcontrolFlashConfigSizeread-onlyoptionalThe total number of bytes in the configuration FLASH, or rather, in one of the two alternating sections.
1.3.6.1.4.1.285.5.16ScalarcontrolFlashConfigFreeread-onlyoptionalThe number of free bytes in the configuration FLASH.
1.3.6.1.4.1.285.5.17ScalarcontrolFlashConfigStateread-writeoptionalControls the state of the FLASH configuration. The states are as follows: normal default - The DEFAULT button has been activated. corrupted - The FLASH configu…
1.3.6.1.4.1.285.5.18ScalarcontrolDelayedRestartread-writemandatoryWriting value n to this variable will cause device to restart after n seconds. Writing zero cancels the reboot. Writing new value when the reboot is already sc…
1.3.6.1.4.1.285.5.19ScalarcontrolLoadProggressread-onlymandatoryNumber of bytes transmitted so far. 0 if no transmission is currently in progress.
1.3.6.1.4.1.285.5.20ScalarcontrolLoadFileSizeread-onlymandatoryLength of the file being transmitted. 0 if no transmission is currently in progress or if the size is unknown.
1.3.6.1.4.1.285.5.21NodecontrolTftpClient
1.3.6.1.4.1.285.5.21.1ScalarcontrolTftpMaxSessionsread-onlyoptionalThe maximum number of simultaneous sessions this device is able to handle.
1.3.6.1.4.1.285.5.21.2ScalarcontrolTftpNextSessionIndexread-onlyoptionalThe unique identifier of the next free TFTP session. This index should be used for manipulating rows in controlTftpSessionTable.
1.3.6.1.4.1.285.5.21.3TablecontrolTftpSessionTablenot-accessibleoptionalThis table makes it possible to control TFTP sessions performed by the built-in device TFTP client.
1.3.6.1.4.1.285.5.21.3.1RowcontrolTftpSessionEntrynot-accessiblemandatoryA list of configuration objects for the TFTP session.
1.3.6.1.4.1.285.5.21.3.1.1ColumncontrolTftpSessionIndexread-onlymandatoryThe TFTP session index.
1.3.6.1.4.1.285.5.21.3.1.2ColumncontrolTftpSessionRowStatusread-writemandatoryThe status of this TFTP session entry. The following values are possible: 'active' - TFTP operation is in progress. Setting this object to this value starts th…
1.3.6.1.4.1.285.5.21.3.1.3ColumncontrolTftpSessionDirectionread-writemandatoryThe direction of this session's transfer.
1.3.6.1.4.1.285.5.21.3.1.4ColumncontrolTftpSessionServerAddressread-writemandatoryThe IP address of the TFTP server used for the transmission.
1.3.6.1.4.1.285.5.21.3.1.5ColumncontrolTftpSessionServerFileread-writemandatoryThe name of the transferred file on the server side.
1.3.6.1.4.1.285.5.21.3.1.6ColumncontrolTftpSessionLocalFileread-writemandatoryThe name of the transferred file on the switch side. In case of upload switch may ignore this variable.
1.3.6.1.4.1.285.5.21.3.1.7ColumncontrolTftpSessionStatusread-onlymandatoryThe status of the session or transmission result when the session was completed. The following values are possible: notInitiated(1) no transfer since this row …
1.3.6.1.4.1.285.5.21.3.1.8ColumncontrolTftpSessionProgressread-onlymandatoryNumber of bytes transmitted so far. 0 if no transmission is currently in progress.
1.3.6.1.4.1.285.5.21.3.1.9ColumncontrolTftpSessionFileSizeread-onlymandatoryLength of the file being transmitted. 0 if no transmission is currently in progress or if the size is unknown.
1.3.6.1.4.1.285.5.22ScalarcontrolRestartTyperead-writemandatoryThe type of restart that will be performed after next reboot request. After any kind of reboot the value of this object should be soft(1) regardles of the prev…
1.3.6.1.4.1.285.6Nodeobm
1.3.6.1.4.1.285.6.1ScalarobmEnableread-writemandatoryThis object controls whether the Olicom Out-Of-Band Management system should be active (enabled) or not.
1.3.6.1.4.1.285.6.2ScalarobmPasswordread-writemandatoryA string containing the password needed to access the device through the OBM communication port. NOTE: Reading the password will return the string `********' -…
1.3.6.1.4.1.285.6.3ScalarobmBaudrateread-writemandatoryThis object controls the baudrate of the communication port used by the Out-of-Band Management system. The 'auto' means automatic UART speed sensing.
1.3.6.1.4.1.285.6.4ScalarobmParityread-writemandatoryThis object controls the parity of the communication port used by the Out-of-Band Management system.
1.3.6.1.4.1.285.6.5ScalarobmStopbitsread-writemandatoryThis object controls the number of stopbits of the communication port used by the Out-of-Band Management system.
1.3.6.1.4.1.285.6.6ScalarobmModemInitread-writemandatoryA string containing the initialization string used to initialize the modem connected to the OBM communication port. This string will be sent `as is'.
1.3.6.1.4.1.285.6.7ScalarobmCallbackEnableread-writemandatoryThis object controls whether the Olicom Out-Of-Band Management Callback sub-system should be active (enabled) or not.
1.3.6.1.4.1.285.6.8ScalarobmCallbackPhoneNumberread-writemandatoryA string containing the default phone number to be used by the callback sub-system. This string will be sent `as is' to the modem connected to the OBM communic…
1.3.6.1.4.1.285.6.9ScalarobmCalloutEnableread-writemandatoryThis object controls whether the Olicom Out-Of-Band Management Callout sub-system should be active (enabled) or not.
1.3.6.1.4.1.285.6.10ScalarobmCalloutPhoneNumberread-writemandatoryA string containing the telephone number to be used by the callout sub-system. This string will be sent `as is' to the modem connected to the OBM communication…
1.3.6.1.4.1.285.6.11ScalarobmCalloutTriggerEventread-writemandatoryThis object controls which events will trigger the callout sub-system to try to establish a connection using the obmCalloutPhoneNumber. The value is a bitmask,…
1.3.6.1.4.1.285.6.12ScalarobmCalloutRetriesread-writemandatoryThis value denotes the number of times the callout sub-system will try to establish a connection using the obmCallbackPhoneNumber string. Used also for call-ba…
1.3.6.1.4.1.285.6.13ScalarobmCalloutRetryTimerread-writemandatoryThis value denotes the number of minutes between unsuccesful attempts to establish a connection using the obmCalloutPhoneNumber string. Used also for call-back.
1.3.6.1.4.1.285.6.14ScalarobmDelayedRecoveryread-writemandatoryThis object controls whether the Olicom Out-Of-Band Management delayed Recovery sub-system should be active (enabled) or not. On a bridge this is controlled by…
1.3.6.1.4.1.285.6.15ScalarobmEnableTelnetread-writeoptionalThis object controls whether the Olicom Out-Of-Band Management can be accessed from telnet.
1.3.6.1.4.1.285.6.16ScalarobmConnectTimeoutread-writeoptionalThis value denotes the number of seconds the user must wait after 3 unsuccesfull attempts to enter the correct password. The default value is 60 sec.
1.3.6.1.4.1.285.6.17ScalarobmDefaultOperationalModeread-writeoptionalThis object controls whether the Olicom Out-Of-Band Management can be accessed via serial console or async PPP/SLIP or selected dynamically (serial or async PP…
1.3.6.1.4.1.285.6.18ScalarobmInactivityTimeoutread-writemandatoryThis object controls value of inactivity timeout [min] which will be used to disconnect an idle user from the Out-of-Band Management system. The default value …
1.3.6.1.4.1.285.6.19ScalarobmDialTyperead-writemandatoryThis object controls if ATDP or ATDT will be sent to a modem while dialing from the Out-of-Band Management system.
1.3.6.1.4.1.285.6.20ScalarobmPasswordReadread-writemandatoryA string containing the password needed to read-access the device through the OBM communication port. NOTE: Reading the password will return the string `******…
1.3.6.1.4.1.285.6.21ScalarobmXonXoffHandshakeread-writemandatoryThe status of Xon/Xoff flow control.
1.3.6.1.4.1.285.6.22ScalarobmRtsCtsHandshakeread-writemandatoryThe status of RTS/CTS handshake.
1.3.6.1.4.1.285.6.23ScalarobmDatabitsread-onlymandatoryNumber of databits to be used by serial interface.
1.3.6.1.4.1.285.7Nodemanagement
1.3.6.1.4.1.285.7.1TablemanagementTablenot-accessiblemandatoryA list of entries for each management system the device supports. NOTE: The SNMP management system is always the first entry in the table.
1.3.6.1.4.1.285.7.1.1RowmanagementTableEntrynot-accessiblemandatoryA management entry contains objects pertaining to a network management system which is supported by this device.
1.3.6.1.4.1.285.7.1.1.1ColumnmanagementNoread-onlymandatoryThe entry number in the management table for this management system.
1.3.6.1.4.1.285.7.1.1.2ColumnmanagementDescriptionread-onlymandatoryA descriptive text for this management system (protocol).
1.3.6.1.4.1.285.7.1.1.3ColumnmanagementAssociationStateread-onlymandatoryThis variable describes the current association between this device and this management system. Some systems are association oriented (e.g. CMIP) and can there…
1.3.6.1.4.1.285.7.1.1.4ColumnmanagementPriorityread-onlymandatoryThis variable describes the relative priority of the management systems supported by this device. The associated management system with the highest managementP…
1.3.6.1.4.1.285.7.2TablemanagementSnmpAccessLogTablenot-accessibleoptionalThis table contains the history log for the last 10 SNMP managers which have accessed this device.
1.3.6.1.4.1.285.7.2.1RowmanagementSnmpAccessLogEntrynot-accessibleoptionalAn entry in the managementSnmpAccessLogTable.
1.3.6.1.4.1.285.7.2.1.1ColumnmanagementSnmpAccessLogIndexread-onlyoptionalThe number of this entry in the managementSnmpAccessLogTable.
1.3.6.1.4.1.285.7.2.1.2ColumnmanagementSnmpAccessLogTimeStampread-onlyoptionalThe time at which the SNMP manager last accessed this device.
1.3.6.1.4.1.285.7.2.1.3ColumnmanagementSnmpAccessLogIpAddressread-onlyoptionalThe IP Address of the SNMP manager.
1.3.6.1.4.1.285.7.2.1.4ColumnmanagementSnmpAccessLogAccessRightsread-onlyoptionalSpecifies the access rights of the SNMP manager.
1.3.6.1.4.1.285.7.2.1.5ColumnmanagementSnmpAccessLogCountread-onlyoptionalSpecifies the number of times the SNMP manager has accessed this device.
1.3.6.1.4.1.285.7.3ScalarmanagementSnmpLastErrorReasonread-onlymandatoryA detailed explanation of why the last SNMP operation failed. It is used by the management station when the SNMP error-status in the response does not fully ex…
1.3.6.1.4.1.285.8Nodefrontpanel
1.3.6.1.4.1.285.8.1ScalarfrontpanelDisplayread-writeoptionalThis variable contains the text that is displayed in the device's frontpanel display.
1.3.6.1.4.1.285.8.2ScalarfrontpanelKeyboardAccessread-writeoptionalThis variable controls whether the keyboard on the device's frontpanel will work. The value enabled(1) means all actions are permitted, status-only(2) means th…
1.3.6.1.4.1.285.8.3ScalarfrontpanelErrorcoderead-writeoptionalThis variable contains the errorcode that is displayed in the device's frontpanel display.
1.3.6.1.4.1.285.8.4ScalarfrontpanelErrorLEDread-writeoptionalThis variable contains the state of the error LED on this device's frontpanel.
1.3.6.1.4.1.285.8.5ScalarfrontpanelDefaultDisplayread-writeoptionalThe display of the device is capable of showing different status displays with different counters. This variable determines which counter-display should be sho…
1.3.6.1.4.1.285.8.6ScalarfrontpanelKeyPresswrite-onlyoptionalSome devices have a front-panel keyboard. This variable may be used to remotely operate the front-panel keyboard.
1.3.6.1.4.1.285.8.7TablefrontpanelDisplayLogTablenot-accessibleoptionalThis table is used to store history logs in the form of a number of display texts, including a corresponding time stamp.
1.3.6.1.4.1.285.8.7.1RowfrontpanelDisplayLogEntrynot-accessibleoptionalThis is an entry in the frontpanelDisplayLogTable.
1.3.6.1.4.1.285.8.7.1.1ColumnfrontpanelDisplayLogIndexread-onlyoptionalThe entry number in the frontpanelDisplayLogTable. In order to ensure that an SNMP GET-NEXT operation produces consistent results, it is recommended that entri…
1.3.6.1.4.1.285.8.7.1.2ColumnfrontpanelDisplayLogTimeStampread-onlyoptionalThe time at which the entry was made.
1.3.6.1.4.1.285.8.7.1.3ColumnfrontpanelDisplayLogDisplayTextread-onlyoptionalThe text string from the front panel display.
1.3.6.1.4.1.285.9Nodeproducts
1.3.6.1.4.1.285.9.1NodetokenRingBridgeSR
1.3.6.1.4.1.285.9.2NodecontrolledAccessUnit
1.3.6.1.4.1.285.9.3NodecontrolledAttachmentModule
1.3.6.1.4.1.285.9.4NodeetherNetAttachmentHUB
1.3.6.1.4.1.285.9.5NodetokenRingRemoteBridgeAndCAM
1.3.6.1.4.1.285.9.6NodetokenRingMultiPortBridge
1.3.6.1.4.1.285.9.7NodedesktopManagementAgent
1.3.6.1.4.1.285.9.8NodelocalPCBridge
1.3.6.1.4.1.285.9.9NoderemoteDOSPCBridge
1.3.6.1.4.1.285.9.10NoderemoteOS2PCBridge
1.3.6.1.4.1.285.9.11NodetokenRingSwitchOc8100
1.3.6.1.4.1.285.9.12NodecrossfireAtmSwitch
1.3.6.1.4.1.285.9.13NodeethernetSwitchOc8200
1.3.6.1.4.1.285.9.14NodetokenRingSwitchOc8600
1.3.6.1.4.1.285.9.15NodetokenRingSwitchOc8007
1.3.6.1.4.1.285.9.16NodecrossfireAtmSwitchOc8008
1.3.6.1.4.1.285.9.17NodefastEthernetSwitchOc8400
1.3.6.1.4.1.285.9.18NodefastEthernetSwitchOc8420
1.3.6.1.4.1.285.9.19NodelanscoutOc5020
1.3.6.1.4.1.285.9.20NodecrossfireAtmSwitchCf9200
1.3.6.1.4.1.285.9.21NodecrossfireRouterCf7100
1.3.6.1.4.1.285.9.22NodetokenRingSwitchCf8500
1.3.6.1.4.1.285.9.23NodeethernetSwitchCf8711
1.3.6.1.4.1.285.9.24NodeethernetSwitchCf8720
1.3.6.1.4.1.285.9.25NodeethernetSwitchCf8810
1.3.6.1.4.1.285.10Nodeerrorlog
1.3.6.1.4.1.285.10.1TableerrorlogTablenot-accessibleoptionalThis table contains a number of error log entries from the managed device.
1.3.6.1.4.1.285.10.1.1RowerrorlogEntrynot-accessibleoptional
1.3.6.1.4.1.285.10.1.1.1ColumnerrorlogNumberread-onlyoptionalThe number of the entry.
1.3.6.1.4.1.285.10.1.1.2ColumnerrorlogTimeStampread-onlyoptionalThis variable describes the device's perception of the time when the error occurred.
1.3.6.1.4.1.285.10.1.1.3ColumnerrorlogErrorDescriptionread-onlyoptionalThis variable contains a description of the error that occurred in this device.
1.3.6.1.4.1.285.10.1.1.4ColumnerrorlogErrorDataread-onlyoptionalThis variable contains additional information about the error.
1.3.6.1.4.1.285.10.1.1.5ColumnerrorlogTimeread-onlyoptionalThis variable describes the device's conception of the calendar time when the error occurred. This is measured in seconds since 00:00:00 on 1 January 1970 (i.e…
1.3.6.1.4.1.285.10.1.1.6ColumnerrorlogTimeRemovedread-onlyoptionalThis variable describes the device's conception of the calendar time when the error condition disappeared. This is measured in seconds since 00:00:00 on 1 Janu…
1.3.6.1.4.1.285.10.1.1.7ColumnerrorlogCategoryread-onlyoptionalThis variable contains the category of the error log
1.3.6.1.4.1.285.10.1.1.8ColumnerrorlogSeverityread-onlyoptionalThis variable contains the severity of the error log
1.3.6.1.4.1.285.10.1.1.9ColumnerrorlogPhysicalIfread-onlyoptionalThis variable contains the physical interface number of the error log, if the log is related to a certain physical interface. Otherwise it will have the value 0
1.3.6.1.4.1.285.10.1.1.10ColumnerrorlogVirtualIfread-onlyoptionalThis variable contains the virtual interface number of the error log, if the log is related to a certain virtual interface. Otherwise it will have the value 0
1.3.6.1.4.1.285.10.2ScalarerrorlogTraceControlread-writeoptionalThe current state of device's trace log area.
1.3.6.1.4.1.285.10.3ScalarerrorlogTraceMaskCurrentread-writeoptionalThe current trace log mask. The interpretation of this variable is device specific.
1.3.6.1.4.1.285.10.4ScalarerrorlogTraceMaskInitialread-writeoptionalThe current trace log mask. The interpretation of this variable is device specific.
1.3.6.1.4.1.285.10.5ScalarerrorlogTraceMaskOperationalread-writeoptionalThe current trace log mask. The interpretation of this variable is device specific.
1.3.6.1.4.1.285.10.6ScalarerrorlogTraceLogSizeread-writeoptionalThe size of the trace log area (in bytes).
1.3.6.1.4.1.285.10.7TableerrorlogTraceSliceTablenot-accessibleoptionalThis table provides access to the device's trace log.
1.3.6.1.4.1.285.10.7.1RowerrorlogTraceSliceTableEntrynot-accessibleoptional
1.3.6.1.4.1.285.10.7.1.1ColumnerrorlogTraceSliceNumberread-onlyoptionalThe number of this trace log area slice (each of size `errorlogTraceSliceSize').
1.3.6.1.4.1.285.10.7.1.2ColumnerrorlogTraceSliceSizeread-onlyoptionalThe size of this slice of the trace log area.
1.3.6.1.4.1.285.10.7.1.3ColumnerrorlogTraceSliceDataread-onlyoptionalThe data in this slice of the trace log area.
1.3.6.1.4.1.285.10.8ScalarerrorlogStoredSeverityLevelread-writeoptionalThis variable contains the severity level determining which error logs will be written to permanent storage. Any error log with severity higher than or equal t…
1.3.6.1.4.1.285.11Nodetrconfig
1.3.6.1.4.1.285.11.1TabletrconfigTablenot-accessibleoptionalThis table contains Token Ring configuration information for each interface.
1.3.6.1.4.1.285.11.1.1RowtrconfigEntrynot-accessibleoptional
1.3.6.1.4.1.285.11.1.1.1ColumntrconfigIfNumberread-onlyoptionalThis number corresponds to the interface number, ifIndex, in ifTable from MIB-II.
1.3.6.1.4.1.285.11.1.1.2ColumntrconfigBurntInAddressread-onlyoptionalThe burnt-in MAC address for this interface.
1.3.6.1.4.1.285.11.1.1.3ColumntrconfigLocalAddressread-writeoptionalThe locally administered MAC address for this interface. If locally address MAC addresses are not used, this entry is all zeroes.
1.3.6.1.4.1.285.11.1.1.4ColumntrconfigEarlyTokenReleaseread-writeoptionalIndicates if early token release is used on the interface.
Type Definitions
NameSyntaxStatusDescription
IPXAddressOCTET STRING (SIZE (12))
MacAddressOCTET STRING (SIZE (6))
RowStatusINTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) }